Droshure Daewang Korea
Droshure Daewang Korea
Temperature Sensor
Pressure Sensor
DAEYANG INSTRUMENT
DAEYANG INSTRUMENT
Printed in Korea October 2011
Published by Daeyang Electric
Designed by Daeyang Design Team
Head office
503, Shinpyung-dong, Saha-gu, Busan, Korea
Tel +82-51-200-5211, 5213, 5209, 5221, 5281
Fax +82-51-200-5210
Seoul office
4F Subon Bldg, 112-19, Samseong-dong
Gangnam-gu, seoul, korea
Tel +82-2-715-3492~3
Fax +82-2-715~3495
DAEYANG ELECTRIC COMPANY I HISTORY
2006-06
Certified as “INNO-BIZ” company by
Small and Medium Business
Administration (SMBA)
2006-11
Co-developed with KORDI an Un-
manned Underwater Vehicle(UUV) for
1977-05
deep sea exploration at 6,000m depth
DAEYANG Electric Co., Ltd. founded.
in the ocean successfully
1977-12
2007-1
Designated as manufacturer of marine
1996-12 Established design research center for
electric equipments by Ministry of
Certified by LRQA for ISO 9001- interior lighting equipments of cruise
Commerce and Industry.
DAEYANG Electric Co., Ltd. in Seoul
1984-04
2000-07 2007-2
Moved main office & factory to current
Selected by “Small & Medium Busi- Developed of LED flat lighting equip-
location. (Shinpyong, Busan)
ness Administration” for “Venture ments.
Company”
1985-09
2007-5
Selected as an “Excellent Exporting
2001-11 Certified by IEC Ex for explosion proof
Company” by the Korea Development
Awarded the “Bronze Tower Order” lighting equipments.
Bank.
for contribution to industry by Ministry
of Commerce, Industry and Energy 2007-7
1988-03 Awarded the “Export Tower” by Ministry Certified by LCIE with ATEX Ex for
Established an affiliated company, Awarded the “Leading Company” by explosion proof lighting equipments.
DAEYANG Instrument Co.,Ltd. Ministry of commerce, Industry and
Energy
2008-7
1988-12
Completed the development of new
DAEYANG R&D center founded. 2002-11
explosion proof lighting equipments
Certified by LRQA for ISO 9001-2000
for land use
1989-01 DAEYANG Electric Co., Ltd. & DAEYANG
Established an affiliated company, Instrument co., Ltd.
2008-11
DAEYANG Electric Supply Co., Ltd.
2003-02 Certified by LRQA for ISO 14001-
Selected as a “National Manufacture DAEYANG Electric Co., Ltd.
1990-11
Research center” by Korean Ministry of
Selected as a defense industry
Commerce, Industry and Energy. 2009-06
company by the Ministry of National
Developed LED lighting for indoor use
Defense
2003-09
Completed the development of 2010-11
1992-03
Goniometer Awarded 30 Million US Dollar Export
Signed a technical license agreement
tower at 47th National Export Day
with WITT & SOHN, Germany
2004-06
Certified by BASEEFA 2001 ATEX for 2010-12
1992-04
explosion proof lighting equipment. Certified by LRQA for OHSAS 18001
Certified by BASEEFA for explosion
proof lighting equipment
2004-09 2011- 01
Completed the development WICS KHNP(KOREA HYDRO & NUCLEAR
1995-08
(Wireless Interior Communication System) POWER CO.,LTD) Approved Vendor
Nominated as one of the most
prominent medium-sized enterprises 2004-12 2011- 07
with advanced technologies by Completed the development of Ni-Rh Flotation on the stock exchange
ministry of commerce and industry electronic reflector (Listed on KOSDAQ)
DAEYANG ELECTRIC COMPANY I ORGANIZATION
Organization
Instrument Design Team
Instrument Production Team
Instrument Quality Assurance Team
Instrument
Division
Sales R&D
Division CENTER
1. History
2. Organization
3. Anemometer & Anemoscope System
3-1. Digital Model
- Cup Type
- Ultrasonic Type
3-2. Analogue Model
- Windvane Type
3-3. Exxon mobil 2010 Requirement
3-4. Acc’y & Option
3-5. Selection Guide
4. Rudder Angle Indicating System
5. Temperature Sensor
5-1. RTD Sensor
5-2. Thermocouple Sensor
5-3. Temperature Switch
5-4. Acc’y & Option
5-5. Application
6. Pressure Sensor
6-1. Pressure Transmitter
6-2. Pressure Switch
6-3. Acc’y & Option
7. LNGC Temperature Measurement System
8. Whistle
9. Certificates
3. Anemometer & Anemoscope System
DAEYANG
INSTRUMENT
3-1. Digital Model
AT-3N
Dimension 212
121
420
290
Ø120
Ø95
BOW
(CABLE GLAND
OPPOSITE DIRECTION) Ø1
2
Dimension
325
385
13
Ø
4 - Ø14
12
(M12
(M10)BOLT)
"BOW"
www.d a ey a n g .c o.k r 7
3-1. Digital Model
Indicator
Dimension 73
60
Max 8mm
158
144
144
Dimension
121
109
211 MAX
192
WIND
0
330 30
DIRECTION MAX.SPEED
300 60
192
178
m/s
270 90
kts
240 120
210 150
180
DIM FUCT
Dimension
121
109
211 MAX
192
WIND
0
330 30
DIRECTION MAX.SPEED
300 60
192
178
m/s
270 90
kts
240 120
210 150
180
DIM FUCT
8 www. da eyang . c o . kr
3-2. Analogue Model
ABOUT 770
Ø125
ABOUT 500
BOW
5-Ø12
MOUNTING HOLES
Caution!
www.d a ey a n g .c o.k r 9
3-2. Analogue Model
Indicator
AI-F3 / AI-S3
Dimension
6-Ø6
150 326
360 170 170 MOUNTING HOLES
206
220
240
FITTING DIMENSION
FL-130S, FL-130D
DESCRIPTION W(kg)
MODEL
A B C D E F G AL PC
FL-130S 150 Ø130 118 22 Ø130 Ø132 124 1.2 0.8
FL-130D 150 Ø130 149 22 Ø130 Ø132 124 1.8 1.2
Dimension
A C
D
B
A E F G
4 - Ø5.5 G
MOUNTING HOLES
FITTING DIMENSION
10 www. da eyang . c o . kr
Speed & Direction Indicator
FL-150S, FL-150D
DESCRIPTION W(kg)
MODEL
A B C D E F G AL PC
FL-150S 3.0 1.6
Ø162 Ø183 Ø150 Ø200 Ø160 Ø136 Ø160
FL-150D 3.7 2.3
Dimension
6-Ø5.5 G
MOUNTING HOLES 60° 60°
C
A
B
D E F
B
6-M5x0.8 TAP
FITTING DIMENSION
FL-200S, FL-200D
DESCRIPTION W(kg)
MODEL
A B C D E F G AL PC
FL-200S 5.0 2.3
Ø212 Ø232 Ø200 Ø250 Ø210 Ø180 Ø160
FL-200D 5.7 3.0
Dimension
6-Ø5.5 G
MOUNTING HOLES 60° 60°
C
A
B
D E F
B
6-M5x0.8 TAP
FITTING DIMENSION
www.d a ey a n g .c o.k r 11
MARINE ENVIRONMENTAL, SAFETY
AND QUALITH ASSURANCE
CRITERIA
FOR
SEAGOING VESSELS IN EXXONMOBIL
AFFILIATE SERVICE
12 www. da eyang . c o . kr
3-3. Exxon Mobil 2010 Requirement
ACP-CB4
MODEL : ACP-CB4
POWER SOURCE : DC24V & AC220V
INPUT : WIND SPEED&DIRECTION
GPS or MASTER CLOCK
OUTPUT : ALARM
PRINTER
DATA LOG
www.d a ey a n g .c o.k r 13
3-3. Exxon Mobil 2010 Requirement
Type : General
Power Source : AC220V 1PH 60Hz (LAMP;12V15W) 0.156A
Weight : 3.94kg
Sound Level : Max.113 – 118dB/m
Lamp Rotating : 120 – 140rpm
IP Grade : 56
14 www. da eyang . c o . kr
4. Rudder Angle Indicating System
DAEYANG
INSTRUMENT
* ISO 20673
This International Standard specifies the construction, performance requirements, methods of testing and required test
results for electric rudder angle indicators required to comply with clause 2.5.4, Regulation 19, chapter V, SOLAS 1974 (as
amended, 2000).
This International Standard is associated with IMO Resolution A.694 (17) and IEC 60945.
Where a requirement in this International Standard is different from IEC 60945, the requirement in this International
Standard takes precedence.
* SOLAS
Within 12 hours before departure, the ship’s steering gear shall be checked and tested by the ship’s crew. The test proce-
dure shall include, where applicable, the operation of the following:
the rudder angle indicators in relation to the actual position of the rudder;
www.d a ey a n g .c o.k r 15
4. Rudder Angle Indicating System
Transmitter
TX-472/TX-453
Dimension
L (LEVER LENGTH)
5° Ø10
10
10
C
5°
A
D
B
E
17
16 www. da eyang . c o . kr
Indicator For W/H MIP
DIMENSION W(kg)
MODEL
A B C D E F AL PC
FL-150 5 2.8
Ø200 Ø250 158 Ø210 Ø212 Ø232
FL-200 5.7 3.0
Dimension
6-Ø5.5 G
MOUNTING HOLES
60° 60°
C
A
B
D
6-M5x0.8 TAP B
FITTING DIMENSION
DIMENSION
MODEL W(kg)
A B C D E F
RI-144 144 50 137 60 138 138 1.1
RI-192 192 100 184 110 185 185 1.6
Dimension C
D
Max 8mm
A
F+1
B
RUDDER ANGLE
PORT STBD
40 40
DEGREE
10 10
0
FITTING &
CUTTING HOLE DIMENSION
www.d a ey a n g .c o.k r 17
4. Rudder Angle Indicating System
DIMENSION
MODEL W(kg)
A B C D E F
3C 300 Ø330 Ø340 Ø439 45 175 Ø416 9
Dimension
°
60
C
B
F
D
30 20 100 10 20 30 40 4030
E
A
6-Ø12
MOUNTING HOLE
DIMENSION W(kg)
MODEL
A B C D E F AL PC
FE-150 3.0 2.3
Ø150 Ø200 155 Ø160 Ø162 Ø183
FL-150 3.7 2.3
Dimension
6-Ø5.5 G
MOUNTING HOLES
60° 60°
C
A
B
D
6-M5x0.8 TAP B
FITTING DIMENSION
18 www. da eyang . c o . kr
SD-150/SD-200/SL-150/SL-200 For BRIDGE WING
DIMENSION CABLE GLAND W(kg)
MODEL
A B C D E F AL PC
SD-150 - 5.4 2.5
Ø150 Ø180 Ø200 145 25b
SL-150 20c 4.2 2.5
SD-200 - 6.5 4.0
Ø200 Ø250 Ø250 145 25b
SL-200 20c 5.9 3.5
FOR STEERING GEAR ROOM
DIMENSION CABLE GLAND W(kg)
MODEL
A B C D E F AL PC
SE-150 Ø150 Ø180 Ø200 145 25b - 4.2 2.5
SE-200 Ø200 Ø250 Ø250 145 25b - 5.9 3.5
Dimension 4-Ø12
MOUNTING HOLE D
16
A
B
70°
F E
www.d a ey a n g .c o.k r 19
4. Rudder Angle Indicating System
DIMENSION W(kg)
MODEL
A B C D E F AL PC
FE-130 1.7 1.2
Ø130 150 149 Ø130 Ø132 124
FL-130 1.8 1.3
Dimension
A C
D
B
E
G
A
4 -Ø5.5 G
MOUNTING HOLES
FITTING DIMENSION
DIMENSION
MODEL W(kg)
A B C D E F
RI-144 144 50 137 60 138 138 1.1
Dimension C
D
Max 8mm
A
F+1
B
RUDDER ANGLE
PORT STBD
40 40
DEGREE
10 10
0
FITTING &
CUTTING HOLE DIMENSION
20 www. da eyang . c o . kr
Option : Converter Unit
RC-CP3
DATE.
SOURCE : AC 16V 60Hz
310
280
SERIAL NO.
NOISE FILTER
SN-M6H-CM
2-M4
FUSE
ON
Rudder Angle STBD/PORT 40, 45, 50, 55, 60, 65, 70 deg
Accuracy ±0.5deg
www.d a ey a n g .c o.k r 21
5. Temperature Sensor
DAEYANG
INSTRUMENT
22 www. da eyang . c o . kr
RTD Sensor
Standard Type of
Platinum Resistance Bulb
Operating Material of Operating
MODEL Remark Class Tolerance(℃)
Range(℃) Protection Tube Temerature(℃)
TTR-LN 0 ~ 200℃ A ±( 0.15 + 0.002 | t | )
1. Norminal -200 ~ 600℃
TTR-LD 0 ~ 350℃ B ±( 0.30 + 0.005 | t | )
SUS 304 Resistance
TTR-SD 0 ~ 600℃ (SUS316 For Pt 100Ω(at 0℃) Note According to DIN RULE
TTR-M Cooling Sea Water) 2. Wire connecting R100/R0 = 1.3851
0 ~ 200℃ terminal
TTR-MN R0 : Resistance Value at 0 °C
R100 : Resistance Value at 100 °C
Note We can make and supply dual element type RB sensor according to your order.
t : measuring temperature
3.2
2.8
2.4
2.0
1.6
Electric Resistance ratio (Rt/Ro)
1.2
0.8
0.4
0
-250 -200 -100 0 100 200 300 400 500 600
Temperature(t°C)
www.d a ey a n g .c o.k r 23
TTR-LN 0 – 200°C
Application
For cooling fresh water, lubricating oil, fuel oil, cool-
ing sea water temperature and
low temperature flow object.
Features
1. High accuracy
2. Rapid response time
3. High durability against vibration.
4. Easy maintenance
5. Replaceable internal element at fitting status
Unit : mm
Dimension
CABLE GLAND 27 47 60 L L ØD S e
JIS F 8801 "G"
25 e
80, 100, 120, 150 12
Standard : PF 3/4
51
S
0
TTR-LD 0 – 300°C
Application
For fuel oil, feed water, cooling water tempera-
ture and medium temperature flow object.
Features
1. High accuracy
2. Rapid response time
3. High durability against vibration.
4. Easy maintenance
5. Replaceable internal element at fitting status
Unit : mm
27 47 (60) L ØDo/D
Dimension CABLE GLAND
L S e
JIS F 8801 "G" or ØD
25 e 80, 100, 120, 150 17 Standard : PF 3/4
5
200, 250 23/17 Option : PF 1/2,
20
51
ØDo
above 300 22
"ØD"
etc
12
Ø7
0
TTR-SD 0 – 600°C
Application
Use for exhaust gas system and high temperature
steam system. Vibration-resistant and shockre-
sistant at high temperature place.
Features
1. Excellent measurement accuracy
25
PF 1/2,
51
Ø15
15 M33, 35
ØD1
350, 400,
ØD
22 NPT 3/4
450, 600
Ø7
0
etc
• Operating Range : 0 ~ 600°C • TTR-S : without protecting well
24 www. da eyang . c o . kr
TTR-A11 -50 ~ 100°C
Application
For indoor, freezing chamber and ambient
temperature.
Features
1. High accuracy
2. Rapid response time
3. High durability against vibration.
CABLE GLAND
100 Ø19
80
2- Ø 7
TTR-MN 0 – 200°C
Application
For stern tube bearing oil temperature.
Features
1. High accuracy
2. Rapid response time
3. High durability against vibration.
4. Replaceable internal element at fitting status
5. Minimum bending radius is 80mm.
Remark
Standard length of protecting tube
Dimension
110 L -3, 5, 7, 9, 11m
CABLE GLAND 44 20 44 Mounting parts are specially designed and
0
Ø7
2-Ø7
Features
1. High accuracy
2. Rapid response time
3. High durability against vibration.
4. Excellent flexibility.
Remark
Standard length of cable : 5, 8m
Mounting parts are specially designed
and should be specified by the user.
• Operating Range : 0 ~ 200°C
www.d a ey a n g .c o.k r 25
RTD Sensor
TTR-LN 0 – 200°C
Application
Use for H.F.O Tank
Features
1. Excellent measurement accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy
5. The element is replaceable
Ø15
TTR-LN 0 – 200°C
Application
Use for H.F.O Tank
Features
1. Excellent measurement accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy
26 www. da eyang . c o . kr
TTR-LD -200 ~ 100 °C
Application
Use for LNG Cargo Tank Spray ,
Liquid , Vapor Line
Features
1. Excellent measurement accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy
Dimension
CABLE GLAND
JIS F 8801 "G" 38 50 40 "L"
60 "e"
25 20
45
Ø32
Ø15
D
Ø8
R3/4
0
Application
Use for LNG Cargo Tank Barrier
Features
1. Excellent measurement accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy
Dimension
80 L
(CABLE LENGTH)
E
14
Ø6.4
"e"
D
"S"
THREAD
PROTECTING TUBE
L ØDO/D S e
6C
FOR M4 TERMINAL 135
TO BE SEPARATED Ø6.4 NPT1/4 14
145
www.d a ey a n g .c o.k r 27
TTR-M -200 ~ 100 °C
Application
Use for LNG Cargo Tank Bulk Head
Features
1. Excellent measurement accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy
NP
L
TO BE SPECIFIED IN
2-Ø9 MEASURING LIST
TCA-D 0 – 600°C
Application
For exhaust gas of engine & boiler, steam and
high temperature flow object.
Vibration-resistant and shock-resistant position
at high temperature.
Features
1. High accuracy
2. Rapid response time
3. High durability against vibration.
4. Easy maintenance.
5. Replaceable internal element at fitting status
Tolerance of Thermocouple(Type K)
Dimension
Operating CABLE GLAND
Class Tolerance(℃)
Temperture(℃) 27 47 (70) "L"
-40~375 ±1.5
1 25 e
375~1000 ±0.004 | t |
"Do"
5
51
Ø15
-40~333 ±2.5
2
ØD1
ØD
333~1200 ±0.075 | t |
Ø
S
• t : measuring temperature
28 www. da eyang . c o . kr
THERMOCOUPLE
TCA-D 0 – 600°C
Application
Use for Cylinder Liner
Features
1. Excellent measurement accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy
Ø7
Ø10
2
PROTECTING TUBE
TCA-D 0 – 600°C
Application
Use for Cylinder Liner
Features
1. Excellent measurement accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy
• Operating Range: 0~600 °C
• CLASS : 2
Dimension
COMPENSATING WIRE
FLEXIBLE TUBE
L
14
e
Ø3.2
S PROTECTING TUBE
SPRING M16x1.5
JK-2C-60T
Application
84
Use for Thermocouple
22 74
Specification
1. Ambient temperature : 0~70°C
2. Input signal : Electromotive force of
POWER
24V DC
4 3
- +
K type
OUT
THERMOCOUPLE AMPLIFIER
MEASURING
/ 0-600 C
EQUIPMENT
DAEYANG INSTRUMENT CO., LTD.
ADJUST
LOAD
SPAN
TYPE JK-2C-60T
K TYPE
79
ZERO
JK-2C-60T
1
INPUT / RANGE
5. Accuracy : ±1.0%
+
THERMO
SERIAL NO.
COUPLE
IN
OUTPUT
- +
2 1
6. Power source : DC 24V ( +10%, -15% )
7. Color of case : RAL 6018
Thermocouple amplifier 8. Measuring range : 0~600°C
www.d a ey a n g .c o.k r 29
TEMPERATURE SWITCH
RT TYPE
Capillary
Model L(mm)
DANFOSS DANFOSS
tube (m)
RT 13 2, 3, 5, 8, 10
A17-712.11 A17-711.11
80
RT 101 2, 3
RT 107 2, 3, 5, 8, 10
110
RT 101 5. 8. 10
2, 3 76
RT 106
RT13, RT10, RT107, RT101 RT106 5 86
Model Code No. Setting range(°C) Max permissible temp(°C) Capillary tube(m)
Dimension 104
83 68
28
Pg13.5
25
61
Ø9.5
122
100
Ø8.5 24
54
61
110
Ø8.5
Ø5
40
CAPILLARY TUBE
KPS TYPE
Dimension M18 x 1.5 CAPILLARY TUBE
L
Ø13
2 - Ø7
Pg13.5
116 90 68
41 81
79 29
11 103 44
120 81
Model Code No. Setting range(°C) Differential range (°C) Max permissible temp (°C) Cap tube (m) L(mm)
KPS 76 060L3113 -10 ~ 30 3 ~ 10 80 2 75
060L3102 2 75, 110
KPS 77 20 ~ 60 3 ~ 14 130
060L3120 5 110
060L3105 2 75, 110
KPS 79 50 ~ 60 4 ~ 16 200
060L3123 5 110
060L3129 2 75, 110
KPS 80 70 ~ 120 4.5 ~ 18 200
060L3131 5 110
060L3107 2 75, 110
KPS 81 60 ~ 150 5 ~ 25 250
060L3135 5 110
KPS 83 060L3109 100 ~ 200 6.5 ~ 30 300 2 75, 110
30 www. da eyang . c o . kr
471 TYPE
Dimension 6.5
G1/2
SW17
SW17
40
THERMOSTAT SW27
L
G1/2 MAX. 6
G
PG13.5 19
64
86
100 12
Maker : Trafag AG
www.d a ey a n g .c o.k r 31
Acc’y & Option
TRANSMITTER
TRANSMITTER
DIGITAL METER
32 www. da eyang . c o . kr
TEST EQUIPMENT
Model ; TP17650M
Power Source ; AC110/220V
Type ; Dry Block
Range ; ambient – 650 °C
Accuracy ; ±1oC
Stability ; ±0.1oC
Power Consumption ; 1000VA
Approval ; GL, DNV
Maker ; SIKA
Model ; MTC-650A
Power Source ; AC110/220V
Type ; Dry Block
Range ; 50 – 650°C
Accuracy ; ±0.9°C
Stability ; ±0.1°C
Power Consumption ; 1150VA
Approval ; DNV
Maker ; AMETEK
Model ; TC-65M
Power Source ; AC110/220V
Type ; Dry Block
Range ; 30 – 650oC
Accuracy ; ±0.5oC
Stability ; ±0.1oC
Power Consumption ; 1600W
Approval ; DNV
Maker ; SCANSENSE
www.d a ey a n g .c o.k r 33
APPLICATION
PIPE LINE
34 www. da eyang . c o . kr
MAIN/AUX ENGINE
TTR-LN
RTD / 0-200°C
TTR-LD TCA-D
RTD / 0-300°C THERMOCOUPLE / 0-600°C
TTR-SD TCA-D
RTD / 0-600°C THERMOCOUPLE / 0-600°C
TTR-M TCA-D
RTD / 0-100°C THERMOCOUPLE / 0-600°C
SCAV. AIR RTD / 0-100°C CYL. LINER/CYL.
THRUST PAD
THRUST BEARING SEGMENT A/C
T/C EXH. GAS
EXH. GAS OUTLET/CYL.
www.d a ey a n g .c o.k r 35
APPLICATION
TTR-MN
RTD / 0-100°C
TANK
TTR-LN
RTD / 0-100°C
TTR-LN TTR-LN
36 www. da eyang . c o . kr
PIPE LINE & SEA WATER
TTR-LN TTR-LD TTR-LN
www.d a ey a n g .c o.k r 37
6. Pressure Sensor
DAEYANG
INSTRUMENT
Pressure Transmitter
EMP-2
Dimension
116 6
100
90
68
Ø7
120
Ø3
117
103
79
29
37
35
Maker: Danfoss A/S 41 68
44
81
Electric connection
Vp-N 4-20mA
P RL +
24 V d.c.
N RL -
Vmax. 36V d.c.
T Imax. ~ 50mA
40-200mV Pmax. ~ 2W
Operating Test Min burst Code no. Operating Test Min burst Code no.
pressure pressure pressure EMP 2 pressure pressure pressure EMP 2
Pe bar Pe bar Pe bar G 1/2 A G 3/8 A Pe kg/cm2 Pe kg/cm2 Pe kg/cm2 G 1/2 A G 3/8 A
-1 - 1.5 5 100 084G2100 -1 - 1.5 5 100 084G2130
-1 - 5 35 200 084G2101 -1 - 5 35 200 084G2131
0.2 - 1 3.2 100 084G2102 0.2 - 1 3.2 100 084G2132
0-1 3.2 100 084G2103 0-1 3.2 100 084G2133
0 - 1.6 3.2 100 084G2104 0 - 1.6 3.2 100 084G2134
0 - 2.5 5 200 084G2105 0 - 2.5 5 200 084G2135 084G2235
0-4 8 200 084G2106 084G2206 0-4 8 200 084G2136 084G2157
0-6 18 400 084G2107 084G2207 0-6 18 400 084G2137 084G2158
0-6 60 400 084G2108 0-6 60 400 084G2138
0 - 10 20 400 084G2109 084G2209 0 - 10 20 400 084G2139 084G2179
0 - 10 60 400 084G2110 0 - 10 60 400 084G2140 084G2149
0 - 16 32 400 084G2111 084G2211 0 - 15 32 400 084G2141 084G2159
0 - 25 50 400 084G2112 0 - 25 50 400 084G2142
0 - 40 80 400 084G2113 084G2213 0 - 40 80 400 084G2143 084G2169
0 - 60 120 400 084G2114 0 - 50 120 400 084G2144
0 - 100 200 400 084G2115 0 - 100 200 400 084G2145
0 - 160 260 640 084G2116 0 - 160 260 640 084G2146
0 - 250 375 1000 084G2117 0 - 250 375 1000 084G2147
0 - 400 600 1600 084G2118 0 - 400 600 1600 084G2148
-1 - 9 20 400 084G2120 -1 - 20 50 400 084G2154
www.d a ey a n g .c o.k r 39
6. Pressure Sensor
SMP-MB
Meiyo
78
80
63
93
118
7
18
CABLE GLAND "G" PF3/8
Maker: Meiyo SEE THE SPECIFICATION TABLE
Electric connection
PRESSURE + + POWER
DC 4-20mA - SUPPLY
TRANSMITTER -
+ -
LOAD
MAX. 550Ω
AT POWER SUPPLY DC24V
Noise emission Complies with standard EN 61000-6-3 -0.1~ 0.4 (-75cm Hg~4)
40 www. da eyang . c o . kr
MBS5100
Dimension
92.5
25.5
CABLE
Ø5.5
15
GLAND
Ø9.8
3
15 15
G1/4
30 20
73 30
84
1 40-200mV
3 +
- UB
2 RL
+ -
STA922 0 ~ 1,040mbar A
Absolute Pressure
STA940 0 ~ 35bar A
STG944 0 ~ 35bar
STG98L 0 ~ 415bar
STD924 0 ~ 1,000mbar
www.d a ey a n g .c o.k r 41
6. Pressure Sensor
Pressure SENSOR
-100 ~ 100kPa
0.75 ~ 100kPa
GTX 30D (-10160 ~ 10160mm-
(75 ~ 10160mmH2O)
CE SIL2 H2O) 2.0kPa A ~ 14MPa
Differential (15mmHg A ~ 140kgf/cm2)
35 ~ 700kPa -100 ~ 700kPa
Pressure GTX 40D
(0.35 ~ 7kgf/cm2) (-1 ~ 7kgf/cm2)
• You can easily select the analogue or digital transmission format through the smart field com-
municator
• A : Absolute
• You can easily select the analogue or digital transmission format through the smart field com-
Maker : YOKOGAWA municator
• A : Absolute
42 www. da eyang . c o . kr
Pressure Switch
RT TYPE
Dimension 110 74
83
23
PG13.5 x 2
(Cable outdia :
6-14mm)
127
100
93
24
Ø5
62
Ø8.5
www.d a ey a n g .c o.k r 43
6. Pressure Sensor
Pressure Switch
KPS TYPE
Dimension
116
90
68 Ø7 6
Ø3
103 79 120
30 40
58 60
G 3/8A
G1/4 41
81
29
35
44
• Maker : Danfoss A/S 68
Setting range Adjustable Permissible over Max. test Min. bursting Pressure
Model Code No.
Pe (bar) diff(bar) pressure (bar) pressure (bar) pressure (bar) connection
KPS 43 060-3120 1 -> 10 0.7 -> 2.8 120 180 240 G 1/4
KPS 45 060-3121 4 -> 40 2.2 -> 1.1 120 180 240 G 1/4
KPS 47 060-3122 6 -> 60 3.5 -> 1.7 120 180 240 G 1/4
MBC5100
Dimension
95
+
25.5
CABLE
GLAND
15
Ø5.5
-
Ø9.8 In
3
15 15
G1/4 1
30 20 3
73 30
2
Out NO
84 Out NC
• Maker : Danfoss A/S
Model Regulation range(bar) Adjustable diff(bar) Max. operating Press(bar) Min. bursting pressure(bar)
MBC5100.1211 -0.2 - 4
0.15 - 0.45 15 30
MBC5100.2211 1-6
MBC5100.2431 1 - 10 0.30 - 2.00
MBC5100.3231 5 - 20 0.40 - 2.50 150 300
MBC5100.3641 5 - 40 1.00 - 7.00
44 www. da eyang . c o . kr
Diff pressure switch
920 TYPE
Dimension
106 36
91
TERMINAL : 1 - 2
P BREAK ON RISE IN PRESSURE
TERMINALS : 1 - 3
MAKE ON RISE IN PRESSSURE
69
2 1 3
** INPUT VOLTAGE : MAX. 250V/AC, DC
• Maker : Trafag AG
size
Model Range Differential Press. Actuator
X Y
RT TYPE
Dimension
110
83 74
62
LP
PG13.5 x 2
(Cable outdia : 6-14mm)
127
100
93
24
Ø5
HP
62
Ø8.5
www.d a ey a n g .c o.k r 45
6. Pressure Sensor
CAS TYPE
116
Dimension 90
68 2-Ø7
Ø3
103
120
79
1/4 BSP
55
41 35 6
81 44
68
1950
Dimension
17/64(6.75) 3-1/2 (88.9)
RANGE ADJUSTMENT
SCREW
4-7/8 (123.8)
5-7/16 (138.1)
NPT1/2 ELEC.
CONDUIT
CONNECTION
CE
46 www. da eyang . c o . kr
Acc’y & Option
MODEL
KAE-11 KAN-11 DVF-11 DVF-11E MKH-110TP MKH-110FPEL
SYM
A 90 85.5 90 90 90 90
C 70 66.5 70 85 85 80
D 20 19 20 24 24 23
E 20 15 15 15 15 30
G M5 M5 M5 M5 M5 M5
www.d a ey a n g .c o.k r 47
6. Pressure Sensor
GAUGE VALVE
THREAD ; PF3/8 x PF3/8
MATERIAL ; BRASS/STEEL/SUS
GAUGE CONNECTOR
THREAD ; PF3/8 x Ø8, Ø10, Ø10.5
MATERIAL ; BRASS/STEEL/SUS
TUBE FITTING
DAMPER
BITE TYPE / 2 FERRULE TYPE
THREAD ; PF3/8 x PF3/8
MATERIAL ; BRASS/STEEL/SUS304/
MATERIAL ; BRASS/STEEL/SUS
SUS316
48 www. da eyang . c o . kr
www.d a ey a n g .c o.k r 49
7. LNGC Measurement System
1.Temperature Sensor for GTT No.96
No. 96 Membrane System is a cryogenic liner directly supported by the ship’s inner hull.
This liner includes two identical metallic membranes and two independent insulation layers.
▪ Picture
50 www. da eyang . c o . kr
2.Temperature Sensor for GTT Mk III
MARK III Membrane System is a cryogenic liner directly supported by the ship’s inner hull.
This liner is composed of a primary metallic membrane positioned on top of a prefabricated insula-
tion panel including a complete secondary membrane.
▪ Picture
www.d a ey a n g .c o.k r 51
7. LNGC Measurement System
(4) Picture
52 www. da eyang . c o . kr
4. Pressure Switch
(4) Picture
www.d a ey a n g .c o.k r 53
7. LNGC Measurement System
54 www. da eyang . c o . kr
6. Instrument Locker
(1) Application
1) No.1/2/3/4 Liquid Dome
2) No. 1/2/3/4 Vapor Dome
3) Manifold Cross-Over
4) F.G E/R INLET
www.d a ey a n g .c o.k r 55
8. Whistle
56 www. da eyang . c o . kr
▪AIR HORN CLASS I
The air whistle is a diaphragm sound transmitter operating on compressed air. The signal is released by an electromagnet
or manually using a hand pull-rope. To avoid the costly laying of a pull-rope, a second electromagnet for emergency volt-
age can be provided. A thermostat controlled anti-condensation heating keeps the sound horn and the operating valve free
from condensed water and thus from ice. Typically the air whistle will operate on air pressures 7bar. For electric release
and operation of the heating a connection to AC220V power supply is required.
The air filter protect the diaphragm from dirt and damage
www.d a ey a n g .c o.k r 57
8. Whistle
58 www. da eyang . c o . kr
▪AIR HORN CLASS I I I
www.d a ey a n g .c o.k r 59
8. Whistle
The electric whistle is driven by an AC 3phase motor. An essential component is the piston inside the cylinder driven by an
AC3phase motor via connecting rod, crankshaft and gearwheels.
The piston oscillates at a certain frequency which makes the air inside the sound projector vibrate in resonance to produce
a sound. When electrical power is supplied to relay box of whistle system as AC3phase, its motor is kept heating status
always except operating. If the motor is operating, heating mode will be paused.
Grease is used to decrease made high-temp. and reduce friction in operating. It is drained as gas through shaft, piston and
horn.
Model No. A B C D E
DEW-143 Ø850 976 1585 370 510
60 www. da eyang . c o . kr
▪ELECTRIC HORN CLASS III
www.d a ey a n g .c o.k r 61
▪RELAY BOX ▪CONTROLLER
▪connection
- W/H -
1 EARTH
AIR WHISTLE (DAW-143)
2
POWER : AC220V,60Hz,1PH - RADAR MAST -
3
4 HEATER 1
5 AC220V,25W 2 H
6 AFT. HORN 3 AH
7 AC220V,60Hz, 1PH 4
WHISTLE CONTROL UNIT (WCU-5F)
8 FORE. HORN
9 AC220V,60Hz, 1PH
10 LIGHT ELECTRIC WHISTLE (DEW-143)
11 (YARD SUPPLY) - FORE MAST -
12 GEN. EM'CY ALARM (7S/1L)
13 (N/O CONTACT) U U
POWER H
14 SYSTEM POWER FAIL 11 V V
AC440V,60Hz,3PH EH
15 (N/O CONTACT) 14 W W
RELAY BOX
16 ELEC. HORN POWER FAIL 21 (DER-440) R
17 22 S POWER
18 SOUND RECEPTION SYSTEM T AC440,60Hz,3PH
(FOR MUTE)
19 (N/O CONTACT)
20 1
PUSH BUTTON (W/H)
21 2
22 MORSE SIGNAL KEY 3
PUSH BUTTON (BRIDGE WING (PORT))
23 (YARD SUPPLY) 4
5
PUSH BUTTON (BRIDGE WING (STBD))
6
YARD T.B
62 www. da eyang . c o . kr
9. Certificates
Manufacturer’s Certificate
www.d a ey a n g .c o.k r 63
EMC
ELECTROMAGNETIC
COMPATIBILITY TEST REPORT
Test Report No. : E074R-001
AC-CB3, AC-TB
SUMMARY
The equipment complies with the Standard; EN 60945: 2002.
This test report contains only the results of a single test of the sample supplied for the examination.
It is not a general valid assessment of the features of the respective products of the mass-production.
It should not be reproduced except in full, without the written approval of ONETECH. EMC-009(Rev.0)
HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-705, Korea
(TEL: +82-31-746-8500, FAX: +82-31-746-8700)
EMC Testing Dept : 307-51 Daessangryung-ri, Chowol-eup, Gwangju-si, Gyeonggi-do, 464-860, Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
Page 1 of 35 Report No.: E073R-056 Page 1 of 42 Report No.: E074R-001 Page 1 of 35 Report No.: E073R-057
ELECTROMAGNETIC
ELECTROMAGNETIC ELECTROMAGNETIC
COMPATIBILITY TEST REPORT
COMPATIBILITY TEST REPORT COMPATIBILITY TEST REPORT
Test Report No. : E074R-001
Test Report No. : E073R-056 Test Report No. : E073R-057
AGR No. : A072A-096
AGR No. : A072A-096 AGR No. : A072A-096
Applicant : DAEYANG INSTRUMENT CO., LTD.
Applicant : DAEYANG INSTRUMENT CO., LTD. Applicant : DAEYANG INSTRUMENT CO., LTD.
Address : 502, SHINPYEONG-DONG, SAHA-KU, BUSAN, KOREA
Address : 502, SHINPYEONG-DONG, SAHA-KU, BUSAN, KOREA Address : 502, SHINPYEONG-DONG, SAHA-KU, BUSAN, KOREA
Manufacturer : DAEYANG INSTRUMENT CO., LTD.
Manufacturer : DAEYANG INSTRUMENT CO., LTD. Manufacturer : DAEYANG INSTRUMENT CO., LTD.
Address : 502, SHINPYEONG-DONG, SAHA-KU, BUSAN, KOREA
Address : 502, SHINPYEONG-DONG, SAHA-KU, BUSAN, KOREA Address : 502, SHINPYEONG-DONG, SAHA-KU, BUSAN, KOREA
Type of Equipment : PROPELLER TYPE ANEMOMETER
Type of Equipment : 3-CUP TYPE ANEMOMETER Type of Equipment : ULTRA-SONIC TYPE ANEMOMETER
Model Name : AT-350, FL-150S, FL-150D, FL-200S, FL-200D, AI-F1, AI-TB1,
Model Name : AT-3N, AI-192, AI-144, AD-F5, JB-2310 Model Name : AT-US, AI-192, AI-144, AD-F5, JB-2310
AC-CB3, AC-TB
Serial number : N/A Serial number : N/A
Multiple Model Name : AI-F2, AI-F3, AI-S1, AI-S2, AI-S3
Total page of Report : 35 pages (including this page) Total page of Report : 35 pages (including this page)
Serial number : N/A
Date of Incoming : March 13, 2007 Date of Incoming : March 13, 2007
Total page of Report : 42 pages (including this page)
Date of Issuing : March 29, 2007 Date of Issuing : March 29, 2007
Date of Incoming : March 13, 2007
SUMMARY SUMMARY
The equipment complies with the Standard; EN 60945: 2002. SUMMARY The equipment complies with the Standard; EN 60945: 2002.
This test report contains only the results of a single test of the sample supplied for the examination. The equipment complies with the Standard; EN 60945: 2002. This test report contains only the results of a single test of the sample supplied for the examination.
It is not a general valid assessment of the features of the respective products of the mass-production. This test report contains only the results of a single test of the sample supplied for the examination. It is not a general valid assessment of the features of the respective products of the mass-production.
It is not a general valid assessment of the features of the respective products of the mass-production.
It should not be reproduced except in full, without the written approval of ONETECH. EMC-009(Rev.0) It should not be reproduced except in full, without the written approval of ONETECH. EMC-009(Rev.0) It should not be reproduced except in full, without the written approval of ONETECH. EMC-009(Rev.0)
HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-705, Korea HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-705, Korea HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-705, Korea
(TEL: +82-31-746-8500, FAX: +82-31-746-8700) (TEL: +82-31-746-8500, FAX: +82-31-746-8700) (TEL: +82-31-746-8500, FAX: +82-31-746-8700)
EMC Testing Dept : 307-51 Daessangryung-ri, Chowol-eup, Gwangju-si, Gyeonggi-do, 464-860, Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) EMC Testing Dept : 307-51 Daessangryung-ri, Chowol-eup, Gwangju-si, Gyeonggi-do, 464-860, Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) EMC Testing Dept : 307-51 Daessangryung-ri, Chowol-eup, Gwangju-si, Gyeonggi-do, 464-860, Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
64 www. da eyang . c o . kr
MED
www.d a ey a n g .c o.k r 65
Worldwide Sales Network
ShangHai Know-How Marine Equipment LTD Tel. Tel. 86-21-64439428 Fax. 86-21-64041979
ADD:Rm.508 Asia Pacific Business Building,No.333 Zhao Jia Bang / 64045956 / 64046912 /
Rm.502, 5/F, City Garden of Vanke,No.197 Shi Hua Road, Huangpu District, Guangzhou, China
Rm.2007, 20/F, Treasure Centre, No.42 Hung To Road, Kwun Tong, Kowloon, Hong Kong
602, Rajhans, Opp. Gaon Devi bus Depot, Naupada, Thane(W), Mumbai-400 602,
Maharashtra, India
Worldwide Sales Network
Worldwide Service Network