Inductive proximity sensors

Plug-in block form C (41 x 40 x 117 mm), plastic, type XS7


5 position turret head
d.c. supply

References, characteristics

Flush mountable in metal


1

1.2

Increased range model


Nominal sensing distance (Sn) 15 mm 20 mm 15 mm 15 mm

References

4-wire a PNP NO + NC XS7-C40PC440 XS7-C40PC449 – –


(complementary
outputs) NPN NO + NC XS7-C40NC440 XS7-C40NC449 – –

2-wire a NO – – XS7-C40DA210 –
(non polarised) NO or NC
programmable – – XS7-C40DP210 XS7-C40DP9B3 (2)

Weight (kg) 0.220 0.220 0.220 0.220

Characteristics

Connection Screw terminals, capacity : 2 or 4 x 1.5 mm2 (1)

Degree of protection IP 67

Operating zone 0…12 mm 0…16 mm 0…12 mm

Approvals UL, CSA pending

Repeat accuracy ≤ 3 % of Sr

Differential travel 3…20 % of Sr

Operating temperature - 25…+ 70 °C

Supply/output state indication Output LED + Supply LED Output LED

Rated supply voltage a 12…48 V

Voltage limits (including ripple) a 10…58 V

Switching capacity (with overload 0…200 mA 1.5…100 mA


and short-circuit protection)

Voltage drop, closed state ≤2V ≤ 5.2 V ≤4V

Residual current, open state – ≤ 0.7 mA

Current consumption, no-load ≤ 10 mA –

Maximum switching frequency 1000 Hz 150 Hz

Delays first-up ≤ 5 ms ≤ 5 ms
response ≤ 0.3 ms ≤ 2 ms
recovery ≤ 0.7 ms ≤ 5 ms
(1) Sensor supplied without cable gland. For suitable n° 13 plastic cable gland (XSZ-PE13), see page 3/0.
(2) 2-wire a non polarised programmable sensors with reduced voltage drop.

1/92 Te
Inductive proximity sensors
Plug-in block form C (41 x 40 x 117 mm), plastic, type XS7
5 position turret head
d.c. supply

Dimensions, setting-up, schemes

Dimensions
XS7-C40Di210, C40DP983 XS7-C40iC44i
1
40 40

20

20
40

40
(3) (4)

25

25
1.2
117

117
60

60
(1) (2) (1)

2xØ5,3 2xØ5,3

(2) (3)

16 = 30 = 16 = 30 =
24 40 24 40
41 41

(1) Output LED (1) Output LED


(2) 1 tapped entry for n° 13 plastic cable gland (2) Supply LED
(3) 2 elongated holes Ø 5.3 x 7 (3) 1 tapped entry for n° 13 plastic cable gland
(4) 2 elongated holes Ø 5.3 x 7

Setting-up
Minimum mounting
distances (mm) Side by side Face to face Facing a metal object and mounting in a metal support.

e e Refer to “Mechanical installation” for block type proximity


sensors mounted in the vicinity of metal masses, page
4/8.

XS7
flush mountable in metal e ≥ 40 e ≥ 120
XS7
increased range models e ≥ 80 e ≥ 240

Wiring schemes
2-wire a (non polarised) 4-wire a
NO or NC output NO + NC output
depending on position of link

+ +
1 1
5 +/– 4 (NO)
PNP NPN
2 (NC) 4 (NO)
6 –/+ 2 (NC)
3 3
– –
NO NO

NC NC

Te 1/93
Inductive proximity sensors
Plug-in block form C (41 x 40 x 117 mm), plastic, type XS8
5 position turret head
d.c. supply

References, characteristics

Non flush mountable in metal


1

1.2

Increased range model


Nominal sensing distance (Sn) 20 mm 40 mm 20 mm

References

4-wire a PNP NO + NC XS8-C40PC440 XS8-C40PC449 –


(complementary
outputs) NPN NO + NC XS8-C40NC440 XS8-C40NC449 –

2-wire a NO – – XS8-C40DA210
(non polarised) NO or NC
programmable – – XS8-C40DP210

Weight (kg) 0.220 0.220 0.220

Characteristics

Connection Screw terminals, capacity : 2 or 4 x 1.5 mm2 (1)

Degree of protection IP 67

Operating zone 0…16 mm 0…32 mm 0…16 mm

Approvals UL, CSA pending

Repeat accuracy ≤ 3 % of Sr

Differential travel 3…20 % of Sr

Operating temperature - 25…+ 70 °C

Supply/output state indication Output LED + Supply LED Output LED

Rated supply voltage a 12…48 V

Voltage limits (including ripple) a 10…58 V

Switching capacity (with overload 0…200 mA 1.5…100 mA


and short-circuit protection)

Voltage drop, closed state ≤2V ≤ 5.2 V

Residual current, open state – ≤ 0.7 mA

Current consumption, no-load ≤ 10 mA –

Maximum switching frequency 1000 Hz 500 Hz 100 Hz

Delays first-up ≤ 5 ms ≤ 5 ms ≤ 5 ms
response ≤ 0.3 ms < 1 ms ≤ 2 ms
recovery ≤ 0.7 ms < 1 ms ≤ 7 ms
(1) Sensor supplied without cable gland. For suitable n° 13 plastic cable gland (XSZ-PE13), see page 3/0.

1/94 Te
Inductive proximity sensors
Plug-in block form C (41 x 40 x 117 mm), plastic, type XS8
5 position turret head
d.c. supply

Dimensions, setting-up, schemes

Dimensions
XS8-C40Di210 XS8-C40iC44i
1
40 40

20

20
40

40
(3) (4)

25

25
1.2
117

117
60

60
(1) (2) (1)

2xØ5,3 2xØ5,3

(2) (3)

16 = 30 = 16 = 30 =
24 40 24 40
41 41

(1) Output LED (1) Output LED


(2) 1 tapped entry for n° 13 plastic cable gland (2) Supply LED
(3) 2 elongated holes Ø 5.3 x 7 (3) 1 tapped entry for n° 13 plastic cable gland
(4) 2 elongated holes Ø 5.3 x 7

Setting-up
Minimum mounting
distances (mm) Side by side Face to face Facing a metal object and mounting in a metal support.

e e Refer to “Mechanical installation” for block type proximity


sensors mounted in the vicinity of metal masses, page
4/8.

XS8 non flush


mountable in metal e ≥ 80 e ≥ 160
XS8 increased
range models e ≥ 160 e ≥ 320

Wiring schemes
2-wire a (non polarised) 4-wire a
NO or NC output NO + NC output
depending on position of link

+ +
1 1
5 +/– 4 (NO)
PNP NPN
2 (NC) 4 (NO)
6 –/+ 2 (NC)
3 3
– –
NO NO

NC NC

Te 1/95
Inductive proximity sensors
Plug-in block form C (41 x 40 x 117 mm), plastic, types XS7 and XS8
5 position turret head
a.c. or d.c. supply

References, characteristics

Flush mountable in metal Non flush mountable in metal


1

1.2
AC AC/DC AC AC/DC

Nominal sensing distance (Sn) 15 mm 20 mm

References

2-wire c NO/NC XS7-C40FP260 – XS8-C40FP260 –


programmable

2-wire c or a NO/NC – XS7-C40MP230 – XS8-C40MP230


universal model programmable

Weight (kg) 0.220 0.220 0.220 0.220

Characteristics

Connection Screw terminals, capacity : 2 x 1.5 mm2 (1)

Degree of protection IP 67

Operating zone 0…12 mm 0…16 mm

Approvals UL, CSA pending

Repeat accuracy ≤ 3 % of Sr

Differential travel 3…20 % of Sr

Operating temperature - 25…+ 70 °C

Supply/output state indication Output LED


c 24…240 V, 50/60 Hz or c 24…240 V, 50/60 Hz or
Rated supply voltage c 24…240 V, 50/60 Hz a 24…210 V c 24…240 V, 50/60 Hz a 24…210 V

Voltage limits c 20…264 V c or a 20…264 V c 20…264 V c or a 20…264 V


c 5…300 mA or c 5…300 mA or
Switching capacity 5…500 mA (2)(2 A inrush) a 5…200 mA (2) 5…500 mA (2)(2 A inrush) a 5…200 mA (2)

Voltage drop, open state ≤ 5.5 V


0.8 mA at 24 V 0.8 mA at 24 V
Residual current, closed state ≤ 1.5 mA 1.5 mA at 120 V ≤ 1.5 mA 1.5 mA at 120 V

Current consumption, no-load –

Maximum switching frequency 25 Hz c 25 Hz, a 50 Hz 25 Hz c 25 Hz, a 50 Hz

Delays first-up ≤ 120 ms


response ≤ 30 ms
recovery ≤ 20 ms
(1) Sensor supplied without cable gland. For suitable n° 13 plastic cable gland (XSZ-PE13), see page 3/0.
(2) These sensors do not incorporate overload or short-circuit protection and therefore, it is recommended that a 0.8 A “quick-blow” fuse be connected in series
with the load. See page 3/0.

1/96 Te
Inductive proximity sensors
Plug-in block form C (41 x 40 x 117 mm), plastic, types XS7 and XS8
5 position turret head
a.c. or d.c. supply

Dimensions, setting-up, schemes

Dimensions
XSi-C40FP260, XSi-C40MP230
1
40

20
40

(3)

25
1.2
117

60

(1)

2xØ5,3

(2)

16 = 30 =
24 40
41

(1) Output LED


(2) 1 tapped entry for n° 13 plastic cable gland
(3) 2 elongated holes Ø 5.3 x 7

Setting-up
Minimum mounting
distances (mm) Side by side Face to face Facing a metal object and mounting in a metal support.

e e Refer to “Mechanical installation” for block type proximity


sensors mounted in the vicinity of metal masses, page
4/8.

XS7 flush
mountable in metal e ≥ 40 e ≥ 120
XS8 non flush
mountable in metal e ≥ 80 e ≥ 160

Wiring schemes
2-wire c programmable 2-wire c or a programmable
NO or NC output depending on position of link NO or NC output depending on position of link

NO NO