RFL® GARD 8000® 3U - Ordering Information

Front Slots 4 - 3 Rear Slots 1 through 4


/-Select 2 Functions-\ /----------------------------Select 4 I/O----------------------------\
Product Smart Number >> GARD 3U

Front Slot 4

Front Slot 3

Rear Slot 1

Rear Slot 2

Rear Slot 3

Rear Slot 4
Front Panel Touch Screen Display
None 0
Yes TSD
Yes with Stylus Tether TSDT
Front Panel Test Switch
None 0
With Audio Tone Test Jacks TA
Standard TD
Primary Power Supply Voltage Input
24 VDC 24
48 VDC 48
125 VDC or 120 VAC 125

250 VDC 250


Redundant Power Supply Voltage Input
None 0
24 VDC 24
48 VDC 48
125 VDC or 120 VAC 125
250 VDC 250

Power Supply Interface


With Multiprotocol (RS-449, V.35, X.21) Digital I/O MP
With Multiprotocol (RS-449, V.35, X.21) Digital I/O & No Power Switch MN
With G.703 Digital I/O G7
With Double Pole Switched Battery Output DP

With Multiprotocol (RS-449, V.35, X.21) Digital I/O & Ext PLC Amp Sw Battery SP
Front System Display Module
With Standard Digital Teleprotection Functionality TP
With 96-Bit Digital Teleprotection Functionality 96
With RFL® 9745 Compatable Digital Teleprotection Functionality 97

Without Digital Teleprotection Functionality No


Redundant Controller
No 0
System I/O Ethernet Port Type
Electrical E
Fiber Optic F

GPS for System Clock Synchronization


Yes G
No 0
Front Functional Modules (Select Eight with 6U and Two with 3U)
Distance Line Protection Relay D

Current Differential Line Protection Relay C

Current Differential Line Protection Relay - Breaker and a Half B & X (uses two slots) Consumes two rear slots in corresponding slot number

Power Line Carrier FSK or On/Off (50 Ohms) w/CLI Meter P5 & 0 (uses two slots) Consumes two rear slots in corresponding slot number

Power Line Carrier FSK or On/Off (75 Ohms) w/CLI Meter P7 & 0 (uses two slots) Consumes two rear slots in corresponding slot number

TX Only Power Line Carrier FSK (50 Ohms) T5 & 0 (uses two slots) Consumes two rear slots in corresponding slot number

TX Only Power Line Carrier FSK (75 Ohms) T7 & 0 (uses two slots) Consumes two rear slots in corresponding slot number

RX Only Power Line Carrier FSK (50/75 Ohms) w/CLI Meter PR & 0 (uses two slots) Consumes two rear slots in corresponding slot number

Power Line Carrier FSK or On/Off - No Hybrid (50 Ohms) w/CLI Meter PN & 0 (uses two slots) Consumes two rear slots in corresponding slot number

Power Line Carrier for External Power Amp PX & 0 (uses two slots) Consumes two rear slots in corresponding slot number

Standard Digital Teleprotection TP

RFL® 9745 Compatable Digital Teleprotection 97

Metering Module M

96-Bit Digital Teleprotection 96

Empty 0

Rear I/O Terminal Block Type


Screw S

Commpression C
Rear I/O Modules (Select Ten with 6U and Four with 3U )
Occupied Slot Based On Front Module Selection X

Empty 0

Ethernet Teleprotection Module - Fiber w/ x2 100Base-FX SFP ET

Ethernet Teleprotection Module - Electrical EE

8 Channel Telemetry Module TM

Audio Tone Teleprotection


Audio Tone Teleprotection with 16-bit Status and Data I/O AU

Digital Communications Modules and Discrete I/O With Discrete I/O >> None Input Red. Input SS Out Relay Out Latch Out Relay Form C

T1 (DB15/RJ48) T0 TI TD TS TR TL TC

E1 (DB15/RJ48) N0 NI ND NS NR NL NC

E1 (BNC 50 or 75 ohm) E0 EI ED ES ER EL EC

Multiprotocol (RS-449, V.35, X.21) M0 MI MD MS MR ML MC

G.703 (DB15) G0 GI GD GS GR GL GC

Dual RS-232 (for pass-thru only) A0 AI AD AS AR AL AC

Short Haul Fiber C37.94, 820nm LED Mulitmode (ST) H0 HI HD HS HR HL HC

Short Haul Fiber C37.94, 820nm LED Singlemode (ST) B0 BI BD BS BR BL BC

Long Haul Fiber, 1300nm LED Singlemode/Multimode (ST) F0 FI FD FS FR FL FC

Long Haul Fiber, 1300nm LASER Singlemode (ST) 30 3I 3D 3S 3R 3L 3C

Long Haul Fiber, 1550nm LASER Singlemode (ST) 50 5I 5D 5S 5R 5L 5C

Discrete I/O Units


6 Inputs IE

6 Redundant Inputs DE

6 Solid State Outputs SE

6 Relay Outputs RE

2 Latching Relay Outputs and 2 Relay Outputs LE

3 Relay Outputs Form C CE

12 Inputs II

12 Redundant Inputs DD

12 Solid State Outputs SS

12 Relay Outputs RR

4 Latching Relay Outputs and 4 Relay Outputs LL

6 Relay Outputs Form C CC

6 Solid State Outputs and 6 Relay Outputs SR

6 Relay Outputs and 3 Relay Outputs Form C SC

6 Solid State Outputs and 6 Inputs SI

6 Relay Outputs and 6 Inputs RI

2 Latching Relay Outputs and 2 Relay Outputs and 6 Inputs LI

2 Latching Relay Outputs and 2 Relay Outputs and 6 Solid Sate Outputs LS

2 Latching Relay Outputs and 2 Relay Outputs and 6 Relay Outputs LR

Current Limiting Output


None 0
48 Vdc CL48
125 Vdc CL125
System Firmware
Standard (Current Released Version) - Blank selection
Version 10.1.0.7263 1
Version 10.2.0.8348 2
Version 10.4.0.9524 3
Effective: 5/9/22