RFL® GARD 8000® 3U - Ordering Information
Front Slots 4 - 3                                                  Rear Slots 1 through 4
                                                                                                                 /-Select 2 Functions-\                          /----------------------------Select 4 I/O----------------------------\
      Product Smart Number >>        GARD          3U
                                                                                                                     Front Slot 4
                                                                                                                                         Front Slot 3
                                                                                                                                                                    Rear Slot 1
                                                                                                                                                                                        Rear Slot 2
                                                                                                                                                                                                            Rear Slot 3
                                                                                                                                                                                                                                Rear Slot 4
Front Panel Touch Screen Display
None                                                     0
Yes                                                     TSD
Yes with Stylus Tether                                  TSDT
Front Panel Test Switch
None                                                              0
With Audio Tone Test Jacks                                        TA
Standard                                                          TD
Primary Power Supply Voltage Input
24 VDC                                                                  24
48 VDC                                                                  48
125 VDC or 120 VAC                                                     125
250 VDC                                                                250
Redundant Power Supply Voltage Input
None                                                                            0
24 VDC                                                                         24
48 VDC                                                                         48
125 VDC or 120 VAC                                                             125
250 VDC                                                                        250
Power Supply Interface
With Multiprotocol (RS-449, V.35, X.21) Digital I/O                                  MP
With Multiprotocol (RS-449, V.35, X.21) Digital I/O & No Power Switch                MN
With G.703 Digital I/O                                                               G7
With Double Pole Switched Battery Output                                             DP
With Multiprotocol (RS-449, V.35, X.21) Digital I/O & Ext PLC Amp Sw Battery         SP
Front System Display Module
With Standard Digital Teleprotection Functionality                                        TP
With 96-Bit Digital Teleprotection Functionality                                          96
With RFL® 9745 Compatable Digital Teleprotection Functionality                            97
Without Digital Teleprotection Functionality                                              No
Redundant Controller
No                                                                                              0
System I/O Ethernet Port Type
Electrical                                                                                           E
Fiber Optic                                                                                          F
GPS for System Clock Synchronization
Yes                                                                                                       G
No                                                                                                         0
Front Functional Modules (Select Eight with 6U and Two with 3U)
Distance Line Protection Relay                                                                                                      D
Current Differential Line Protection Relay                                                                                          C
Current Differential Line Protection Relay - Breaker and a Half                                                  B & X (uses two slots)                           Consumes two rear slots in corresponding slot number
Power Line Carrier FSK or On/Off (50 Ohms) w/CLI Meter                                                           P5 & 0 (uses two slots)                          Consumes two rear slots in corresponding slot number
Power Line Carrier FSK or On/Off (75 Ohms) w/CLI Meter                                                           P7 & 0 (uses two slots)                          Consumes two rear slots in corresponding slot number
TX Only Power Line Carrier FSK (50 Ohms)                                                                         T5 & 0 (uses two slots)                          Consumes two rear slots in corresponding slot number
TX Only Power Line Carrier FSK (75 Ohms)                                                                         T7 & 0 (uses two slots)                          Consumes two rear slots in corresponding slot number
RX Only Power Line Carrier FSK (50/75 Ohms) w/CLI Meter                                                          PR & 0 (uses two slots)                          Consumes two rear slots in corresponding slot number
Power Line Carrier FSK or On/Off - No Hybrid (50 Ohms) w/CLI Meter                                               PN & 0 (uses two slots)                          Consumes two rear slots in corresponding slot number
Power Line Carrier for External Power Amp                                                                        PX & 0 (uses two slots)                          Consumes two rear slots in corresponding slot number
Standard Digital Teleprotection                                                                                                     TP
RFL® 9745 Compatable Digital Teleprotection                                                                                         97
Metering Module                                                                                                                     M
96-Bit Digital Teleprotection                                                                                                       96
Empty                                                                                                                               0
Rear I/O Terminal Block Type
Screw                                                                                                                                                        S
Commpression                                                                                                                                                 C
Rear I/O Modules (Select Ten with 6U and Four with 3U )
Occupied Slot Based On Front Module Selection                                                                                                                                          X
Empty                                                                                                                                                                                  0
Ethernet Teleprotection Module - Fiber w/ x2 100Base-FX SFP                                                                                                                            ET
Ethernet Teleprotection Module - Electrical                                                                                                                                           EE
8 Channel Telemetry Module                                                                                                                                                            TM
Audio Tone Teleprotection
Audio Tone Teleprotection with 16-bit Status and Data I/O                                                                                                                             AU
Digital Communications Modules and Discrete I/O                                      With Discrete I/O >> None      Input                Red. Input              SS Out            Relay Out           Latch Out          Relay Form C
T1 (DB15/RJ48)                                                                                            T0                TI                          TD         TS                  TR                  TL                  TC
E1 (DB15/RJ48)                                                                                            N0               NI                           ND         NS                  NR                  NL                  NC
E1 (BNC 50 or 75 ohm)                                                                                     E0               EI                           ED         ES                  ER                  EL                  EC
Multiprotocol (RS-449, V.35, X.21)                                                                        M0              MI                            MD         MS                  MR                  ML                  MC
G.703 (DB15)                                                                                              G0              GI                            GD         GS                  GR                  GL                  GC
Dual RS-232 (for pass-thru only)                                                                          A0               AI                           AD         AS                  AR                  AL                  AC
Short Haul Fiber C37.94, 820nm LED Mulitmode (ST)                                                         H0               HI                           HD         HS                  HR                  HL                  HC
Short Haul Fiber C37.94, 820nm LED Singlemode (ST)                                                        B0               BI                           BD         BS                  BR                  BL                  BC
Long Haul Fiber, 1300nm LED Singlemode/Multimode (ST)                                                     F0                FI                          FD         FS                  FR                  FL                  FC
Long Haul Fiber, 1300nm LASER Singlemode (ST)                                                             30                3I                          3D         3S                  3R                  3L                  3C
Long Haul Fiber, 1550nm LASER Singlemode (ST)                                                             50                5I                          5D         5S                  5R                  5L                  5C
Discrete I/O Units
6 Inputs                                                                                                                                                                               IE
6 Redundant Inputs                                                                                                                                                                    DE
6 Solid State Outputs                                                                                                                                                                 SE
6 Relay Outputs                                                                                                                                                                       RE
2 Latching Relay Outputs and 2 Relay Outputs                                                                                                                                           LE
3 Relay Outputs Form C                                                                                                                                                                CE
12 Inputs                                                                                                                                                                               II
12 Redundant Inputs                                                                                                                                                                   DD
12 Solid State Outputs                                                                                                                                                                SS
12 Relay Outputs                                                                                                                                                                      RR
4 Latching Relay Outputs and 4 Relay Outputs                                                                                                                                           LL
6 Relay Outputs Form C                                                                                                                                                                CC
6 Solid State Outputs and 6 Relay Outputs                                                                                                                                             SR
6 Relay Outputs and 3 Relay Outputs Form C                                                                                                                                            SC
6 Solid State Outputs and 6 Inputs                                                                                                                                                     SI
6 Relay Outputs and 6 Inputs                                                                                                                                                           RI
2 Latching Relay Outputs and 2 Relay Outputs and 6 Inputs                                                                                                                              LI
2 Latching Relay Outputs and 2 Relay Outputs and 6 Solid Sate Outputs                                                                                                                  LS
2 Latching Relay Outputs and 2 Relay Outputs and 6 Relay Outputs                                                                                                                      LR
Current Limiting Output
None                                                                                                                                                                                                                                            0
48 Vdc                                                                                                                                                                                                                                        CL48
125 Vdc                                                                                                                                                                                                                                       CL125
System Firmware
Standard (Current Released Version) - Blank selection
Version 10.1.0.7263                                                                                                                                                                                                                                   1
Version 10.2.0.8348                                                                                                                                                                                                                                   2
Version 10.4.0.9524                                                                                                                                                                                                                                   3
                                                                                                                                                                                                                          Effective: 5/9/22