0% found this document useful (0 votes)
36 views2 pages

9369 Techdata

Uploaded by

pejmanp
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views2 pages

9369 Techdata

Uploaded by

pejmanp
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product: 9369

High Perform Instr, 3 Pr #18 Str TC, PVC Ins E2, IS, PVC Jkt, PLTC

Product Description
High Performance Instrumentation, 3 Pair 18AWG (19x30) Tinned Copper, PVC Insulation E2 Color Code, Individual Beldfoil® Shield, PVC Outer Jacket, PLTC

Technical Specifications

Product Overview

Suitable Applications: Instrumentation, Sensors, Valves, Positioners, 4-20mA, 0-10V

Construction Details

Conductor

Element No. of Elements Size Stranding Material

Pair(s) 3 18 AWG 19x30 TC - Tinned Copper

Insulation

Element Material Nom. Thickness Nom. Insulation Diameter Color Code

Pair(s) PVC - Polyvinyl Chloride 0.019 in (0.48 mm) 0.082 in (2.1 mm) ICEA Chart E2

Inner Shield

Element Shield Type Material Coverage Drainwire Type Notes

Pair(s) Tape Bi-Laminate (Alum+Poly) 100% 20 AWG (19x32) TC each pair

Outer Jacket

Separator Material Nom. Thickness Nom. Diameter Ripcord

PP - Polypropylene Tape PVC - Polyvinyl Chloride 0.053 in (1.3 mm) 0.456 in (11.6 mm) Yes

Overall Cable Diameter (Nominal): 0.456 in (11.6 mm)

Electrical Characteristics

Electricals

Nom. Conductor
Element Nom. Inner Shield DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Shield Max. Current
DCR

Pair(s) 7.2 Ohm/1000ft 8.18 Ohm/1000ft (26.8 Ohm/km) 57 pF/ft (190 pF/m) 102 pF/ft (335 pF/m) 3.5 Amps per Conductor at 25ºC

Voltage

UL Voltage Rating

300 V (PLTC, CMG)

Mechanical Characteristics

Temperature

UL Temperature Operating

105°C -30°C to +105°C

Table Notes: AWM 80°C

Bend Radius

Stationary Min. Installation Min.


4.5 in (110 mm) 4.5 in (110 mm)

Max. Pull Tension: 163 lbs (73.9 kg)

Bulk Cable Weight: 105 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial

Flammability / Reaction to Fire: UL 1685 UL Loading, FT4, T-29-520, IEEE 1202

NEC / UL Compliance: Article 725, Article 727, Article 800, CMG, ITC, PLTC

AWM Compliance: AWM 2464

CEC / C(UL) Compliance: CMG

European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)

APAC Compliance: China RoHS II (GB/T 26572-2011)

History

Update and Revision: Revision Number: 0.576 Revision Date: 04-14-2023

Part Numbers

Variants

Item # Color UPC Footnote

9369 0601000 Chrome 612825239635 C

9369 0602500 Chrome 612825239642 Z

9369 060500 Chrome 612825239659 C

9369 0605000 Chrome 612825239666 C Z

© 2023 Belden, Inc


All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.

You might also like