IOTAFLOW Profile NEW
IOTAFLOW Profile NEW
IOT/AMR |
CALIBRATION
Our Lean Journey- Continuously Improving….
Pursuit Of Calm And Efficiency From
At IOTAFLOW, we prioritize efficiency and
State Of Chaos And Fighting Fires
continuous improvement in our operations. A
quest to avoid firefighting with timely delivery
and quality of the products lead us to discover
2SL. Our commitment to lean principles began
in October 2021. Since then our implementation
efforts encompass comprehensive training
programs on reducing 8 wastes, implementation
of the 2 Second Lean philosophy, utilization of
Kanban Cards for inventory control, adoption
of the Supermarket Concept, and implementation
of the One-Piece Flow methodology.
2
10 PARTNERS, 1 VISION: Precision in Flow Measurement
Hover over the Partner Logo to navigate to their website.
Germany
United Kingdom
Czech
Discover our
partners
Canada Poland with single scan
Russia
France
Japan
Switzerland India
Welcome to IOTAFLOW! Where the essence of our name reflects our commitment to precision Flow Measurement Solutions. Derived from "IOTA", meaning minuscule or minute,
we embody this concept by crafting flow meters with an iota of error. The word "FLOW" underscores our unwavering dedication to designing instruments for everything that could
flows be it Air, Water, Oil, Gas, Steam, or Chemicals. Yes, we have it all.
At IOTAFLOW, we reject the notion of a one-size-fits-all approach. Instead, we embrace a vision where our customers receive bespoke technological solutions without compromise.
To achieve this, we've forged strategic partnerships with ten domain leaders across Europe, Canada, and Japan. These collaborations empower us to offer a diverse range of
cutting-edge technologies without the need to push any particular product & / or technology.
A significant milestone in our journey came in 2019 when we entered into a technical collaboration agreement with renowned European companies like Aflowt & Vzljot. These
partnerships have enabled us to manufacture and distribute their high-quality products (MID & OIML Certified) across India and neighbouring regions, marking a new chapter
in our story of growth and innovation.
3
WATER METER
R
Hydraulic part material: Brass Maximum pipeline pressure, MPa / bar: 2.5 / 25 Four Track)
Installation: Return flow/forward flow horizontal/ Fluid temperature range, °С: 50°С/130°С Clamp-on PEA Accuracy, %, with flowrate range from
vertical (For Hot Water)
E
1:100: -
Protection: IP65 (IP68 optional) Ambient temperature range, °С: 5 - 65°С Single-beam sounding ±2 | Two-beam sounding ±1 |
End Connection: Threaded (ANSI Flanged Optional) Protection: IP67 (IP68 optional) Four-beam sounding ±0.5
Display: LCD, 8 digits + icons, Units: m3 End Connection: ASME/ANSI B16. 5 Class 150,
T
Flow velocity range 0.1-20 m/s
Interfaces: Pulse, M-BUS, Wireless M-BUS, RS485, Tri-Clover, Fluid temperature range: - 30- (+160) °С, Ambient
Optical, RF ultra narrow band PN16 temperature for transmitter, 0 – (+50)°С Maximum
In- Built LoraWAN optional
A
Compliance: ISO 4064 pipeline pressure: 2.5/25 MPa/bar
Power supply: Battery Operated 3,6 V, Lithium, Interfaces: Pulse, RS485, Analog 4-20mA (Optional) Transmitter/transducers protection IP54/IP68
12 years In- Built LoraWAN optional Measurement data logging,
W
Date history in EEPROM memory: 60 Months, Power supply: Battery Operated 3,6 V, Lithium, number of records: -Hourly log 1440 - Daily log 60 -
184 Days, 1488 hours 12 years, Power Operated (Optional) Monthly log -Programmable 14400 -Batching 512
*AMR Enabled Measurement data logging, Power supply: 24VDC, Power consumption: <12W
Suitable Applications: Domestic, Residential/ number of records: - 1440 Hourly log- 460 Transmitter weight: <3 kg,
Commercial Buildings. Daily log- 48 Transmitter dimensions: 250x132x90 mm.
Monthly log
*For AMR details Refer (Page no.13) CE, MID Certified.
4
CLAMP-ON PORTABLE AREA VELOCITY
(FIXED) (CLAMP-ON) (DOPPLER
ULTRASONIC ULTRASONIC EFFECT)
1500 SERIES AV5500 SERIES
Nominal diameter of the pipeline, Principle, Transit Time, CE approved *Ideal for Open Channels &
DN 15-6000 Pipe Range: 13mm ID to 10,000mm OD Partially Filled Pipes
Principle, Transit Time Transducer Operating Temp: -20°C to +135°C Measures flow Velocity and Level simultaneously
V206 Probe (For difficult Applications) Sensor cable - 7.6 m / 25 ft submersible, shielded
R
(Optional Hi-Temp -20°C to +200°C)
Measuring Channels: 1 to 4 (Single Track | Dual Track Display shows flow rate, total flow, signal and battery 3-coaxial pairs
| Four Track) level Flow rate range: 0.1 to 20 ft/sec and reverse flow to-5
E
Clamp-on PEA Accuracy, %, with flowrate range from Non-invasive sensing ft/sec
1:100: - Language options: English, French, German, Spanish Accuracy: Velocity- ± 2% of reading or ± 0.04 ft/sec
Single-beam sounding ±2 | Two-beam sounding ±1 | Carrying case: IP67 Rated (whichever is greater)
T
Four-beam sounding ±0.5 Battery or mains operation (Battery Life 14 Hours, Accuracy: Level - ± 0.25% of reading or ± 0.08’’
Flow velocity range 0.1-20 m/s 2.5 Hours charging time) (whichever is greater)
Fluid temperature range: - 30- (+160) °С, Ambient Accuracy: +/-0.5% to +/-3% dependent on flow and Enclosure: watertight, NEMA4X (IP66) polycarbonate
A
temperature for transmitter, 0 – (+50)°С Maximum pipe size Totalizer: 14 Digit
pipeline pressure: 2.5/25 MPa/bar Turn Down Ratio: 100:1. Calibration: built-in 5-key programmer
Transmitter/transducers protection IP54/IP68 Data Communications: USB, supports most USB 2.0 Outputs – three isolated 4-20mA/0-5V, Flow, Level
W
Measurement data logging, BOM drives. and Velocity
number of records: -Hourly log 1440 - Daily log 60 - Output: 3 x Pulse Output, 4-20mA Output 2 control relays - 5 amp, SPDT - programmable for
Monthly log -Programmable 14400 -Batching 512 Data Logging: 100,000,000 data points. 12 named flow proportional pulse output, flow and/or level
Power supply: 24VDC, Power consumption: <12W sites. alarm
Transmitter weight: <3 kg, Download via USB to CSV file and export to Excel. Datalogger: 128 Megabyte storage capacity
Transmitter dimensions: 250x132x90 mm. Temperature Sensors: Clamp-on PT100 Class B 4 wire, (6.5 million points)
range 0°C – 200°C (32°F – 392°F), resolution 0.1°C Power input - 100-240VAC 50/60Hz, 10 VA maximum
(0.18°F). Minimum delta T is 0.3°C (Optional). CE, UL/SCA/EN 61010-1
Pl Note*- Portable Doppler Effect (D550 Series) also
available.
5
ELECTROMAGNETIC CX/VN/VNS MULTIJET &
FLOW METER COMPACT WOLTMANN
(EMF STANDARD) ELECTROMAGNETIC WATER METERS,
FLOW METERS AQUA-RE SERIES
R
Features: Built-in flow rate recording & controlling
Liner Material: Teflon, PFA, F46, Neoprene, Body: Brass or Stainless Steel
function
Polyurethane. Accuracy: Class B as per ISO 4064 suitable for Cold Water
Design: Compact, easy to install
(50°C) /Hot water ( 90°C & 130°C versions)
E
Electrode Type: General type, Scraper type and Model-Specific Applications:
Display parameters: flow rate / total / reset-able total
Replaceable type. VNS: Designed for Sodium Hypochlorite and Caustic Relay output on flow rate
Electrode Material: SS316, Hastelloy B, Hastelloy C, Soda measurement. Outputs: Pulse output for AMR communication
T
Titanium, Tantalum, Platinum-iridium, stainless steel CX: Ideal for coolant water in die-casting, injection Analog (4 ~ 20 Ma) output, 24 VDC input (In digital
covered with tungsten. molding, and welding machines. Option) In built battery (life 1.5 ~ 2 years) (Optional)
Ambient Temperature:- 25°C~+60°C WOLTMANN
A
Medium Electrical conductivity: ≥5.0 s/cm, Turbine Mechanical water Meter with Magnetic
Measuring Range: 500:1, flow rate 10m/s Transmission
• Structure Type: Integral type, Remote type, Pipe Range: DN50 - Dn500 Removable mechanism, 360°
W
Submersible type, Ex Proof type. Rotatable
Protection Class: IP68 Dustproof and submersible for Accuracy: Class B as per ISO 4064 suitable for Cold
long (only for remote type) Water (50°C) /Hot water ( 90°C & 130°C versions)
• Ex-proof Mark: Exd II BT4 Body: Cast Iron or Stainless Steel with an epoxy outer
CE, MID Certified coating
Suitable Applications: Slurries, Chemicals (Acids & Display parameters: flow rate / total / reset-able total
Alkalis), Raw/Sewage Water, etc. Relay output on flow rate
*Insertion Electromagnetic available for pipes Dn200 Outputs: Pulse output for AMR communication Analog
and above. (4 ~ 20 Ma) output, 24 VDC input (In digital Option) In
built battery (life 1.5 ~ 2 years) (Optional).
6
POSITIVE DISPLACEMENT OIL METERS
Pipe Range: DN4 - DN80 Pipe Range: DN10 - DN200 Pipe Range: DN5 - DN10
Outputs: Pulse, Analog 4-20 mA High Temperature & High viscosity Connection R1/4 - R1/2
continuous for remote monitoring Applications Max Pressure: 5 bar
External power supply Battery Back-up option Higher Accuracy, 0.5% or 0.2%. Max Temp.: 70 deg C
Flange (DIN, ANSI, JIS), threaded ends Standard Viscosity up to 5,000 cP (centipoise = MPa.s) Output: Voltage pulses / Open collector - pl choose
Accuracy: 0.5 % to 1 % Size of wide flow ranges 0.04-340 M3/h while ordering
Independent of viscosity and Temperature, with 0.5 meter long cable
L
(18-37,396GPM).
Mechanical display with Resettable Totalizer Wide range of working environment: (-20)~(+280) °C Pulse value: 0.46 ml/pulse
No Straight run required Available in Cast Iron, Cast Steel, and Stainless Steel. Applied voltage range: 3 - 24 VDC
I
Temperature ranges 130 and 180°C Options include LC display, transmitter, and MCU Power consumption: 0.2 VA or less
Nominal Pressure PN 16, 25 and 40 Bar flow process controller. MOC: case and rotor: PPS, O ring - NBR and Shaft -
Suitable Applications: Heating fuel Extra light / Light, SS304
O
Medium, Heavy naphtha diesel petrol and other Application: Adblue Dispensing or DEF Flow Meters
Lubricating liquids (Oils). for diesel cars, Urea Dispensing
Weak acid/weak alkaline, Cool/hot water, kerosene,
light oil, heavy oil
7
AIR FLOW METERS
R
Built-In Temp. & Pressure compensation Analogue outputs for temperature and flow rate:
Power Supply: External 24VDC±10% 0... 10
Output: 4-20mA (±0.5%FS) / RS485 V/4... 20 mA (protected against short circuits)/ Pulse
I
Measurable Fluids: Compressed Air, Nitrogen Operating temperature: 20...+120°C (350°C
Certifications: RoHS, CE, UKCA. High temp Optional)
A
ATEX category II 3G Ex nA ic IIC T4 Gc (On request)
Measurable Fluids: Compressed Air, Nitrogen,
Oxygen, Biogas, Natural Gas & other Speciality
CONICAL SHAPED
Gasses.
FLOW METER
8
STEAM FLOW METERS
Insertion VFM
Pipe Range: DN20 - DN800 with Insert
Pipe Range: DN350 - DN2000
Mechanism
Accuracy: ± 1% FS (0.5% FS Optional) Built-In Temp. & Pressure compensation (Option
Fluid temperature: < 250°C (High temp < 350 °C With Insertion Mechanism for Uninterrupted Standard
Optional)
M
Maintenance Insertion
Operating Pressure: Upto 16 Bar (40 Bar on request) Type VFM
Power Supply: 24VDC ± 10%
Built-In Temp. & Pressure compensation (Option) Operating Pressure: 16 Bar
Power Supply: External 24VDC±10% Output: Pulse, 4-20mA / RS485 / HART (On request)
A
Output: 4-20mA / RS485 / HART (On request) Display Protection: IP65, IP68, Flameproof
Display Protection: IP65, IP68, Flameproof (CMRI Certified) (On request)
(CMRI Certified) (On request)
E
Measurable Fluids: Steam, Air, Liquids & other
Measurable Fluids: Steam, Air, Liquids & other Aggressive Gasses
Aggressive Gasses
T
Certifications: IBR Approved.
S
9
FUEL GAS FLOW METERS
S
Operation temperature range: Options for built-in or external GSM/3G modems, Accuracy: ±1.5%
- gas temperature -10°C up to +60°C Protection: IP66 Elcor: MID Certified Gas Volume Corrector (Optional)
- ambient temperature -10°C up to +60°C Explosion-proof: 1Ex ib IIB T4 Gb X HIGHLIGHTS
A
Type Examination Certificate FTZÚ 15 ATEX 0172X Measurable Gasses: Natural & Fuel Gases High accuracy and stability of measurement
Marking of equipment Ex II -/2G IIB T4 Built-in Temperature, Pressure & Gas correction, Embedded modem 2G/3G/4G/NB
No straight Run required No need of external corrector. Robust design
G
Oil Free Maintenance Modular technology
Elcor: MID Certified Gas Volume Corrector (Optional). MID and ATEX approved
Long battery life
Designed for the future
upgrades
Tamper proof.
10
GAS FLOW METERS
UF-BIOSONIC CONICAL
(ULTRASONIC SHAPED FLOW
FLOW METER
MEASUREMENT
FOR BIOGAS)
S
Communication: RS485/4 ~ 20mA End Fittings: Flanged, threaded, hub or weld-end
VORTEX FLOW METER
Protection: Ip65. standard; Others on request.
RTD:
A
• Sensor Type: PT-100, thin film
• Range: -58° to 752° F (-50° to 400° C) For complete Vortex Flow Meter details,
Manifold: Configuration: 3-Valve please navigate to page 9 for all this
G
dP Transmitter: insights!
• Housing Material: F30 Aluminum
• Membrane Material: 316L
• Enclosure Rating: NEMA 4X/6P, IP66/67
• Electrical Connections: NPT1/2 thread
Flow Computer: • Output: 4-20 mA, Isolated Pulse
Pressure Range:Up to 1500 psi (100 bar)
Temperature Range: up to 1,600 °F (870°C)
Applications: Biogas, Coke Oven gas, Coal Bed
Methane (CBM), Gas Mixtures, Air (with Dust), Steam.
11
ROTAMETERS (ALL FLUIDS)
R
Material: Aluminum alloy case with Pipe Range: DN6 - DN 100 Meter Type: Glass Tube Rotameter
E
paint. Float Material: PTFE / SS 316 / Metal Tube Rotameter / Gauge
Body wetted parts: in SS316, PTFE lined, plastic. Media: Air, Water, Oil, Gas & Solvents Carrier Ring/Orifice Flange: SS-316/ SS-304/ MS/ PP
Others on request. Indication via magnetic coupling
T
Mounting: In-Line / Panel Mounted with Needle Valve Bypass Line: SS-316/ SS-304/ MS / PVC
(no sealed) End Connection: Screwed / Flanged Type of Tapping: On Flange, D and D/2, corner
Connection types: Flange type, Trip Clamp & Sanitary Operating Temp: 70℃ Connection: Top & Boom Flanged or Threaded / Rear
E
(others on request) Operating Pressure: 10 Bar Installaon: Vercal Upward & Downward / Horizontal
Temperature: 200℃ ( 300 ℃ Option) Mounting Accuracy: Bottom to Top : +2% on FSD Left to Right & Right to Left
Housing protection: IP65/IP67 or Explosion Proof, Range ability: 7:1 to 5:1
Measuring Tube Float Scale: Laser Engraved on Body
M
CLASS I, GROUPS B, C &D; CLASS II, GROUPS E, F, & Accessories: Hi - Low Flow Switch
Connection Flange: PP / MS / SS 304 / SS 316
G; NEMA 4, 7, 9 Accuracy: ±2% on Full Scale
Accuracy: ±2% FS, (±1.6 F.S Option)
A
Max pressure: 40 kg/cm2 (standard) (Option: up to
100 kg/cm²)
Option: Switch available (Micro Switch: 3A/250VAC,
T
5A/30VDC, 0.4/125VDC), Adjustable inductive alarm
switch, 4 - 20 mA two wires analog output available
O
R
12
IOTAFLOW (I/O SENSE) IOT SYSTEM
The ultimate solution for industrial monitoring
4G/WiFi/Ethernet
Connectivity
Integrated automation
and supervisory control of water supply
and sanitation facilities as per Statutory
guidelines (CGWA)
Monitoring Cloud
Application Software Consumption at the subscriber (household
metering)
Gateway
Metering Devices
4G/GPRS/GSM
Module / LoraWan
Communication
13
Service Support
We are pleased to inform you that IOTAFLOW offers Installation, Commissioning & AMC services to ensure the seamless integration and operation of your flow
measurement instruments.
Our expert team will work closely with you to meet your unique requirements and provide long-term, reliable service for your equipment. For any queries or to schedule a
consultation, feel free to reach out to us.