Agilent 11970 Series

Harmonic Mixers
Data Sheet

For use with the Agilent E4407B, 8560E/EC Series,


8566B, and 71000 Series Spectrum Analyzers

• Excellent frequency response


• Low conversion loss
• No bias or tuning adjustments
• High safe input level, 100 mW
• Amplitude calibrated
18 to 110 GHz
11970K, 11970A,
11970Q, 11970U,
11970V, 11970W

Exceptional performance This series of mixers has been designed for a local
The Agilent Technologies 11970 series harmonic oscillator frequency of 3 to 6.1 GHz. Accurate
mixers are general purpose mixers employing a absolute amplitude measurements can be made by
dual-diode design to achieve very flat frequency using the mixer’s conversion loss calibration chart.
response and low conversion loss. Each mixer is The SWR of the waveguide input is typically 2.2:1
calibrated across its full band: to further minimize measurement uncertainty. The
combination of high gain-compression level and low
11970K, 18 to 26.5 GHz conversion loss provides the maximum dynamic
11970A, 26.5 to 40 GHz range for measuring input signals.
11970Q, 33 to 50 GHz
11970U, 40 to 60 GHz
11970V, 50 to 75 GHz
11970W, 75 to 110 GHz
Easy to use Rugged
The excellent frequency response and low conver- The rugged Agilent 11970 Series Mixers will sur-
sion loss are achieved without external dc bias or vive input levels up to 100 milliwatts (+20 dBm)
tuning stubs. Since bias and tuning stubs are not with no damage to the mixer diodes. They will
required, manual operation is simplified, and the withstand shocks up to 30 G’s and the vibration
complexity of hardware and software for automatic required by MIL-STD 28800C, Type III, Class 3
systems is greatly reduced. The repeatability of tests.
amplitude measurements is also enhanced. The
dual-diode design of the mixers further simplifies Frequency extension for the Agilent E4407B,
measurements by suppressing the odd-order har-
monics by more than 20 dB, which makes identifi-
8560E/EC Series, 8566B, and 71000 Series
cation of the mixing products easier. spectrum analyzers
The 11970 Series Harmonic Mixers are fully com-
patible with the Agilent E4407B, 8560E/EC Series,
8566B, and 71000 Series Spectrum Analyzers.
Accurate frequency and amplitude measurements
are made directly from the spectrum analyzer’s
display after calibration using the mixer’s calibra-
tion chart. The 11975A Microwatt Power Amplifier
can be used with the 8566B Spectrum Analyzer to
provide the necessary LO power of 14 to 18 dBm to
the mixers. The 11975A has internal power leveling
to achieve maximum measurement accuracy.

Figure 1. A conversion loss chart is attached to each mixer.

Agilent E4407B Spectrum Analyzer Agilent 8566B Spectrum Analyzer


Extended Frequency E4407B ESA-E Series Extended Frequency 8566B Spectrum Analyzer

Agilent 8560E/EC Series Spectrum Analyzer Agilent 71000 Series Spectrum Analyzer
Extended Frequency 8560E/EC Series Extended Frequency 71000 Series Spectrum Analyzer

2
Specifications
IF range DC to 1300 MHz
LO amplitude range +14 to +18 dBm1
Calibration accuracy
(with IF of 321.4 MHz)
11970A/Q/U ±2.0 dB with LO amplitude range of +14.5 to +16 dBm;
±3.0 dB with LO amplitude range of +16 to +18 dBm

11970V/W ±2.6 dB with LO amplitude range of +14.5 to +16 dBm;


±3.2 dB with LO amplitude range of +16 to +18 dBm
Typical RF input SWR
11970A/Q/U <2.2:1
11970V/W <2.6:1
Bias requirements None
Typical odd-order
suppression
11970A/Q/U >20 dB
11970V/W >15 dB
Maximum CW RF
input level +20 dBm (100 mW)
Maximum peak
pulse power +24 dBm (250 mW) with <1 m sec
pulse (average power +20 dBm)

Specifications describe the device’s warranted performance over the temperature range 0 to 55˚ C
(except where noted).
Supplemental characteristics are typical, but non-warranted, performance parameters intended to provide
information useful in applying the device. These are denoted as “typical,” “nominal,” or “approximately.”

Frequency LO Maximum Spectrum analyzer Frequency Typical gain


Agilent model range harmonic conversion noise (dBm) response compression
number (GHz) number loss (dB) 1 kHz BW (dB) (dBm)

11970K 18–26.5 6– 24 –105 ±1.9 –3


11970A 26.5–40 8– 26 –102 ±1.9 –5
11970Q 33–50 10– 28 –101 ±1.9 –7
11970U 40–60 10– 28 –101 ±1.9 –7
11970V 50–75 14– 40 –92 ±2.1 –3
11970W 75–110 18– 46 –85 ±3.0 –1

Agilent model
number Flange Weight X Y Z

11970K UG-595/U 0.17 kg 36 mm 51 mm 90 mm


WR-42 0.36 lb 1.4 in 2.0 in 3.5 in
11970A UG-599/U 0.14 kg 36 mm 51 mm 71 mm
WR-28 0.32 lb 1.4 in 2.0 in 2.8 in
11970Q UG-383/U 0.14 kg 36 mm 51 mm 76 mm
WR-22 0.32 lb 1.4 in 2.0 in 3.0 in
11970U UG-383/U-M 0.14 kg 36 mm 51 mm 76 mm
WR-19 0.32 lb 1.4 in 2.0 in 3.0 in
11970V UG-385/U 0.14 kg 36 mm 51 mm 76 mm
WR-15 0.32 lb 1.4 in 2.0 in 3.0 in
11970W UG-387/U 0.14 kg 36 mm 51 mm 76 mm
WR-10 0.32 lb 1.4 in 2.0 in 3.0 in

1. The Agilent 11975A amplifier (2 to 8 GHz) or a similar amplifier can be used to provide sufficient LO power (14 to 18 dBm) to the mixers.
An LO power of between 14.5 to 16 dBm at the mixer’s LO input is necessary to achieve the given frequency response and spectrum
analyzer amplitude accuracy specifications. When LO power varies between 14 to 18 dBm at the mixer’s LO input, add ±1 dB to the
frequency response and spectrum analyzer amplitude accuracy specification. 3
Ordering information Agilent Technologies’ Test and Measurement Support, Services, and Assistance
Agilent Technologies aims to maximize the value you receive, while minimizing your
risk and problems. We strive to ensure that you get the test and measurement
11970K 18 to 26.5 GHz mixer capabilities you paid for and obtain the support you need. Our extensive support
11970A 26.5 to 40 GHz mixer resources and services can help you choose the right Agilent products for your
11970Q 33 to 50 GHz mixer applications and apply them successfully. Every instrument and system we sell has a
global warranty. Support is available for at least five years beyond the production life
11970U 40 to 60 GHz mixer of the product. Two concepts underlie Agilent’s overall support policy: “Our Promise”
11970V 50 to 75 GHz mixer and “Your Advantage.”
11970W 75 to 110 GHz mixer Our Promise
Options: Our Promise means your Agilent test and measurement equipment will meet its
advertised performance and functionality. When you are choosing new equipment,
11970X-009 Mixer connection kit containing three we will help you with product information, including realistic performance specifica-
1-meter SMA cables, wrench, and allen tions and practical recommendations from experienced test engineers. When you
driver. Note: X = K, A, Q, U, V or W use Agilent equipment, we can verify that it works properly, help with product
operation, and provide basic measurement assistance for the use of specified
11970X-C01 Improved EMC radiated susceptibility. capabilities, at no extra cost upon request. Many self-help tools are available.
Note: X = K, A, Q, U, V or W
Your Advantage
11975A 2 to 8 GHz amplifier (for use with the Your Advantage means that Agilent offers a wide range of additional expert test and
8566B) measurement services, which you can purchase according to your unique technical
and business needs. Solve problems efficiently and gain a competitive edge by
contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs,
Warranty and service and on-site education and training, as well as design, system integration, project
management, and other professional engineering services. Experienced Agilent
engineers and technicians worldwide can help you maximize your productivity,
For warranty and service of 5 years, please order 60 months optimize the return on investment of your Agilent instruments and systems, and
of R-51B (quantity = 60). Standard warranty is 12 months. obtain dependable measurement accuracy for the life of those products.

By internet, phone, or fax, get assistance with all your


R-51B Return-to-Agilent warranty and test and measurement needs.

service plan Online assistance:


www.agilent.com/find/assist
Agilent Email Updates Phone or Fax
Japan:
(tel) (81) 426 56 7832
United States:
www.agilent.com/find/emailupdates (fax) (81) 426 56 7840
(tel) 1 800 452 4844
Get the latest information on the
Korea:
products and applications you select. Canada:
(tel) (82 2) 2004 5004
(tel) 1 877 894 4414
(fax) (82 2) 2004 5115
(fax) (905) 282 6495
Taiwan:
China:
(tel) 080 004 7866
(tel) 800 810 0189
(fax) (886 2) 2545 6723
(fax) 1 0800 650 0121
Other Asia Pacific Countries:
Europe:
(tel) (65) 375 8100
(tel) (31 20) 547 2323
(fax) (65) 836 0252
(fax) (31 20) 547 2390
Email: tm_asia@agilent.com
Latin America:
(tel) (305) 269 7500
(fax) (305) 269 7599

Product specifications and descriptions in this document


subject to change without notice.

© Agilent Technologies, Inc. 2002


Printed in USA, March 21, 2002
5968-1445E

You might also like