T Tad1171ve
T Tad1171ve
TAD1171VE
22294508 07
Important
This Technical Data Sheet and the corresponding Installation Instructions provide important information to ensure the installed
engine will operate according to the design specification in the Volvo Penta application for certification.
Requirements marked with are considered as critical for exhaust emissions compliance according to the design
specification in the Volvo Penta application for certification.
Failing to follow and meet these instructions and requirements when installing a certified engine in a piece of nonroad equipment
for use in the United States violates U.S. federal law (40 CFR 1068.105(b)), subject to fines or other penalities as described in the
Clean Air Act.
General
In-line four stroke diesel engine with direct injection. Rotation direction, counterclockwise viewed towards flywheel
Number of cylinders 6
Displacement, total liters 10,84
in3 661
Firing order 1-5-3-6-2-4
Bore mm 123
in 4,84
Stroke mm 152
in 5,98
Compression ratio 17,0:1
Wet weight Engine only (Estimated) kg 1072
(excl after treatment comp.) lb 2363
Power pac kg 1351
lb 2978
1 / 19
Document No Issue Index
TAD1171VE
22294508 07
Engine brake performance (only engines with VCB) rpm 1200 1500 1900 2200
Brake power: without fan kW 70 120 170 185
hp 95 163 231 252
Brake torque: without fan Nm 557 764 854 803
lbf ft 411 563 630 592
Engine speed range for VCB activation: rpm 1000-2200
Min engine speed with VCB still active: rpm 900
Min oil temperature for VCB activation: °C 55
Block heater type Make Power kW Engaged hours Cooling water temp
(-30°C) engine block
Self circulating Volvo 1,2 12 -1°C
30°F
* See also general section in the sales guide
Lubrication system
Lubricating oil consumption (average) Vol% 0,05
2 / 19
Document No Issue Index
TAD1171VE
22294508 07
Fuel system
System supply flow at max. Speed liter/h 108
US gal/h 28,5
Fuel supply line max. restriction kPa 20
(measured at fuel inlet connection) psi 2,9
Fuel supply line max. pressure, during engine stand still kPa 16,5
(measured at fuel inlet connection and high tank/low tank positions) psi 2,4
Fuel supply line min. pressure, during engine stand still kPa -12,5
(measured at fuel inlet connection and high tank/low tank positions) psi -1,8
System return flow at max. Speed liter/h 30,0
US gal/h 7,9
Fuel return line max. restriction kPa 20
(measured at fuel return connection) psi 2,9
Max. allowable inlet fuel temp °C 60
(Measured at fuel inlet connection) °F 140
Prefilter / Water separator micron size µ 10
Governor type/make, standard Volvo/EMS2.3
Injection pump type/make
Specific UREA consumption in Nonroad Transient Cycle (NRTC) Vol% 5,0
Fuel to conform to Fuel equal to or better than EN590:2009 or
ASTM D975-09 and Max sulphur 15ppm
Max allowable temperature drop between turbine and SCR muffler Δ°C 10 10 10 10
inlet. Δ°F 18 18 18 18
SCR muffler pressure drop kPa 12 11 10 10
(at exhaust gas flow and exhaust temp given) psi 1,7 1,6 1,5 1,5
3 / 19
Document No Issue Index
TAD1171VE
22294508 07
Cooling system rpm 1400 1800 2000 2100
Heat rejection radiation from engine at: IFN Power 265 kW kW 7 8 9 9
BTU/min 398 455 512 512
kW
BTU/min
kW
BTU/min
Heat rejection to coolant at: IFN Power 265 kW kW 113 130 140 150
BTU/min 6426 7393 7962 8530
kW
BTU/min
kW
BTU/min
Coolant Yellow Volvo Coolant Solution (VCS)
Radiator cooling system type Closed circuit
Standard radiator core area m² 0,8
foot² 8,61
m²
foot²
Fan diameter 890mm mm 890
in 35,04
890mm mm 890
in 35,04
Fan power consumption 890mm kW 8,0 18,0 24,0 28,0
hp 11 24 33 38
890mm kW
hp
Fan drive ratio fan Ø890 1,01:1 ccw
Coolant capacity: engine liter 17
US gal 4,5
std. 0,8m² radiator with hoses liter 21
US gal 5,5
Coolant pump drive/ratio belt/1,41:1 cw
Coolant flow with standard system l/s 4,8 6,2 6,8 7,1
US gal/s 1,3 1,6 1,8 1,9
Minimum coolant flow l/s 2,1 2,5 2,5 2,7
US gal/s 0,6 0,7 0,7 0,7
Maximum outer circuit restriction incl. piping kPa 55,0
psi 8,0
Thermostat: start to open °C 82
°F 180
fully open °C 92
°F 198
Maximum static pressure head kPa 100
(expansion tank height + pressure cap setting) psi 14,5
Minimum static pressure head kPa 70
(expansion tank height + pressure cap setting) psi 10,2
Standard pressure cap setting kPa 75
psi 10,9
Maximum top tank temperature °C 107
°F 225
Recommended Draw down capacity.
The difference between min coolant level in the expansion tank and the lowest liter 2
level where the engine's coolant system still are functioning
US gal 0,5
4 / 19
Document No Issue Index
TAD1171VE
22294508 07
Charge air cooler system rpm 1400 1800 2000 2100
Heat rejection to charge air cooler IFN Power 265 kW kW 49 50 52 55
BTU/min 2787 2843 2957 3128
Charge air mass flow IFN Power 265 kW kg/s 0,37 0,42 0,44 0,46
IFN Power 265 kW
5 / 19
Document No Issue Index
TAD1171VE
22294508 07
Engine management system
Functionality Alternatives Default setting
Governor mode Isochronous
Droop Isochronous
Governor droop 10 127 Nm/rpm
Governor response Adjustable PI constants
Idle speed 600 900 rpm 700
If preheat is available, preheat will be
Request +
Preheating function Ignition Request active at ignition on if temp low or
temp
demanded by driver.
Ignition off stops engine Yes No No
Engine overspeed rpm 2400 N/A Fault code only Fault code only
Derated 0% to
Derated 100% to engine Forced idle after 5 Forced shut down
Derate parameters engine protection
protection map sec after 0 sec
map
Oil temp 130°C 132°C N/A N/A
Coolant temp 107°C 108°C N/A N/A
Charge air temp 125°C 126°C N/A N/A
EGR temp N/A N/A N/A N/A
6 / 19
Document No Issue Index
TAD1171VE
22294508 07
Electrical system
Voltage and type 24V
Alternator: output A 110/150
tacho output Hz/alternator rev. 6
drive ratio 5,25
Starter motor: type 90P55 / (105P70 ISS för start/stop)
output kW 5,5 / (7,0)
hp
Number of teeth on: flywheel 153
starter motor 11
Inlet manifold heater (at 20 V) kW 3
Power relay for the manifold heater A 1
Max wiring resistance main circuit mΩ 3
7 / 19
Document No Issue Index
TAD1171VE
22294508 07
Power take off - Rear with Flywheel housing Standard rpm 1400 1800 2000 2100
Front end in line with crank shaft max:* Nm 1700 1370 1250 1200
(with a total added mass moment of inertia, J (mR2)≤0,05 kgm²) lbf ft 1254 1010 922 885
Front end belt pulley load. Direction of load viewed from max side kW 13 17 19 20
flywheel side: hp 18 23 26 27
Pulley diameter 201mm with distance 190mm from max down kW 13 17 19 20
main bearing 1 hp 18 23 26 27
max up kW 34 47 52 55
hp 46 64 71 75
Maximum torque on timing gear at rear PTO : * Nm 650
lbf ft 479
Speed ratio direction of rotation viewed from flywheel side 1,08:1/ ccw
Timing gear at compressor PTO max:* Nm 310
lbf ft 229
Speed ratio direction of rotation viewed from flywheel side 1,29:1 / ccw
Max allowed bending moment in flywheel housing Nm 7000
lbf ft 5163
Max. rear main bearing load N 3000
lbf 674,4
8 / 19
Document No Issue Index
TAD1171VE
22294508 07
kW Power
300
250
200
150
100
50
0
0 500 1000 1500 2000 2500
rpm
Nm Torque
2000
1800
1600
1400
1200
1000
800
600
400
200
0
0 500 1000 1500 2000 2500
rpm
9 / 19
Document No Issue Index
TAD1171VE
22294508 07
Nm
Altitude derated Torque IFN Power 265
2000
1800
1600
1400
1200
1000
800
600
400
200
0
0 500 1000 1500 2000 2500
rpm
10 / 19
Document No Issue Index
TAD1171VE
22294508 07
rpm
11 / 19
Document No Issue Index
TAD1171VE
22294508 07
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
600 800 1000 1200 1400 1600 1800 2000 2200
rpm
g/kWh
Fuel Consumption
230
225
220
215
210
205
200
195
190
600 800 1000 1200 1400 1600 1800 2000 2200
rpm
12 / 19
Document No Issue Index
TAD1171VE
22294508 07
370
350
330
310
290
270
250
500 700 900 1100 1300 1500 1700 1900 2100 2300
rpm
Warning Level Alarm Level
350
300
250
200
150
100
50
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
rpm
Warning Level
13 / 19
Document No Issue Index
TAD1171VE
22294508 07
350
300
250
200
150
100
50
0
0 500 1000 1500 2000 2500
rpm
14 / 19
Document No Issue Index
TAD1171VE
22294508 07
120
110
100
90
80
70
60
50
40
20 31,5 50 80 125 200 315 500 800 1,25 2k 3,15 5k 8 12,5 20k
Frequency Hz
IFN Power
265 kW
124
122
120
118
116
114
112
110
108
106
104
102
100
98
96
0 500 1000 1500 2000 2500
rpm
IFN Power
265 kW
15 / 19
Document No Issue Index
TAD1171VE
22294508 07
Outer circuit
Outer circuit restriction versus coolant flow
restriction kPa
200
180
160
140
120
100
80
60
40
20
0
0 1 2 3 4 5 6 7 8 9 10
60
55
50
45
40
35
30
25
20
15
10
31,5 63 125 250 500 1000
Frequency Hz
16 / 19
Document No Issue Index
TAD1171VE
22294508 07
3,000
2,500
2,000
1,500
1,000
0,500
0,000
0,0000 2,0000 4,0000 6,0000 8,0000 10,0000 12,0000
m³/s
2200 2000 1800 1600 1400 1200 fan rpm
HD-fan Ø 750mm
Fan rpm=Fan ratio*Engine speed
kW
35
30
25
20
15
10
0
0,0000 2,0000 4,0000 6,0000 8,0000 10,0000 12,0000 14,0000
m³/s
2200 2000 1800 1600 1400 1200
17 / 19
Document No Issue Index
TAD1171VE
22294508 07
3,5
2,5
1,5
0,5
0
0,0 2,0 4,0 6,0 8,0 10,0 12,0 14,0 16,0 18,0 20,0
m³/s
2200 2000 1800 1600 1400 1200
50,00
40,00
30,00
20,00
10,00
0,00
0,0 2,0 4,0 6,0 8,0 10,0 12,0 14,0 16,0 18,0 20,0
m³/s
2200 2000 1800 1600 1400 1200
18 / 19
Document No Issue Index
TAD1171VE
22294508 07
BSFC [g/kWh]
19 / 19