Document No Issue Index

TAD1171VE
22294508 07
Important
This Technical Data Sheet and the corresponding Installation Instructions provide important information to ensure the installed
engine will operate according to the design specification in the Volvo Penta application for certification.

Requirements marked with are considered as critical for exhaust emissions compliance according to the design
specification in the Volvo Penta application for certification.

Failing to follow and meet these instructions and requirements when installing a certified engine in a piece of nonroad equipment
for use in the United States violates U.S. federal law (40 CFR 1068.105(b)), subject to fines or other penalities as described in the
Clean Air Act.

General
In-line four stroke diesel engine with direct injection. Rotation direction, counterclockwise viewed towards flywheel

Number of cylinders 6
Displacement, total liters 10,84
in3 661
Firing order 1-5-3-6-2-4
Bore mm 123
in 4,84
Stroke mm 152
in 5,98
Compression ratio 17,0:1
Wet weight Engine only (Estimated) kg 1072
(excl after treatment comp.) lb 2363
Power pac kg 1351
lb 2978

Performance rpm 1400 1800 2000 2100


IFN Power 265 kW without fan kW 256 265 265 265
hp 348 360 360 360
with fan kW 248 247 241 237
890 mm hp 337 336 328 322
Torque at: IFN Power 265 kW Nm 1746 1406 1265 1205
lbf ft 1288 1037 933 889
Max torque at engine rpm 1260 rpm Nm 1750
speed lbf ft 1291
Power tolerance % ±2
Mean piston speed m/s 7,1 9,1 10,1 10,6
ft/sec 23,3 29,9 33,2 34,9
Effective mean pressure at: IFN Power 265 kW MPa 2,02 1,63 1,47 1,40
psi 294 236 213 203
Max combustion pressure at: IFN Power 265 kW MPa 16 15 15 12
psi 2320 2175 2175 1740
Total mass moment of inertia, J (mR2) kgm² 1,034
(not including flywheel) lbft² 24,5
Friction Power kW 20 29 36 49
hp 27 39 49 67
Derating see Technical Diagrams

1 / 19
Document No Issue Index
TAD1171VE
22294508 07

Engine brake performance (only engines with VCB) rpm 1200 1500 1900 2200
Brake power: without fan kW 70 120 170 185
hp 95 163 231 252
Brake torque: without fan Nm 557 764 854 803
lbf ft 411 563 630 592
Engine speed range for VCB activation: rpm 1000-2200
Min engine speed with VCB still active: rpm 900
Min oil temperature for VCB activation: °C 55

Cold start performance


*Cold start limit temperature without starting aid °C -15
°F 5
with manifold heater 3 kW °C -25
°F -13
with manifold heater 3 kW and °C -35
block heater °F -31
*Specify oil and fuel quality T>-15°C Oil VDS3 or VDS4 15W/40
T<-15°C Oil VDS3 or VDS4 5W/40

Block heater type Make Power kW Engaged hours Cooling water temp
(-30°C) engine block
Self circulating Volvo 1,2 12 -1°C
30°F
* See also general section in the sales guide

Lubrication system
Lubricating oil consumption (average) Vol% 0,05

Oil system capacity including filters liter 37


US gal 9,77
Oil pan capacity: Max liter 32
(both variants) US gal 8,45
Min liter 27
US gal 7,00
Oil change intervals/specifications VDS3 h 1000
VDS4 h 1000
Engine angularity limits: front up ° 30
front down ° 30
side tilt ° 30
Oil pressure at rated speed kPa 350 - 600
psi 51 - 87
Lubrication oil temperature in sump: max °C 130
°F 266
Oil filter filtration efficiency 99% µ 38
(in accordance with ISO 4548-12) 50% µ 14
Oil filter micron size µ 40

2 / 19
Document No Issue Index
TAD1171VE
22294508 07
Fuel system
System supply flow at max. Speed liter/h 108
US gal/h 28,5
Fuel supply line max. restriction kPa 20
(measured at fuel inlet connection) psi 2,9
Fuel supply line max. pressure, during engine stand still kPa 16,5
(measured at fuel inlet connection and high tank/low tank positions) psi 2,4
Fuel supply line min. pressure, during engine stand still kPa -12,5
(measured at fuel inlet connection and high tank/low tank positions) psi -1,8
System return flow at max. Speed liter/h 30,0
US gal/h 7,9
Fuel return line max. restriction kPa 20
(measured at fuel return connection) psi 2,9
Max. allowable inlet fuel temp °C 60
(Measured at fuel inlet connection) °F 140
Prefilter / Water separator micron size µ 10
Governor type/make, standard Volvo/EMS2.3
Injection pump type/make
Specific UREA consumption in Nonroad Transient Cycle (NRTC) Vol% 5,0
Fuel to conform to Fuel equal to or better than EN590:2009 or
ASTM D975-09 and Max sulphur 15ppm

Intake and exhaust system rpm 1400 1800 2000 2100


Charge air consumption at: IFN Power 265 kW m³/min 18,7 21,1 22,2 23
(+25°C and 100kPa) cfm 660 745 784 812

See front page for important information


kPa 6
Max allowable air intake restriction including piping psi 0,9
Heat rejection to exhaust at: IFN Power 265 kW kW 178 222 242 246
BTU/min 10123 12625 13762 13990
Exhaust gas temperature after turbine at: IFN Power 265 kW °C 426 467 484 476
°F 799 873 903 889

See front page for important information

Max allowable back pressure in exhaust line (after turbine) kPa 17 18 18 18


Pipe dimension Ø: 125 mm psi 2,5 2,6 2,6 2,6

See front page for important information

Max allowable temperature drop between turbine and SCR muffler Δ°C 10 10 10 10
inlet. Δ°F 18 18 18 18
SCR muffler pressure drop kPa 12 11 10 10
(at exhaust gas flow and exhaust temp given) psi 1,7 1,6 1,5 1,5

Pre-catalyst pressure drop kPa N/A N/A N/A N/A


psi
Exhaust gas flow at:
(temp and pressure after turbine at the IFN Power 265 kW m³/min 40,2 47,6 51 52,6
corresponding power setting) cfm 1420 1681 1801 1858

3 / 19
Document No Issue Index
TAD1171VE
22294508 07
Cooling system rpm 1400 1800 2000 2100
Heat rejection radiation from engine at: IFN Power 265 kW kW 7 8 9 9
BTU/min 398 455 512 512
kW
BTU/min
kW
BTU/min
Heat rejection to coolant at: IFN Power 265 kW kW 113 130 140 150
BTU/min 6426 7393 7962 8530
kW
BTU/min
kW
BTU/min
Coolant Yellow Volvo Coolant Solution (VCS)
Radiator cooling system type Closed circuit
Standard radiator core area m² 0,8
foot² 8,61

foot²
Fan diameter 890mm mm 890
in 35,04
890mm mm 890
in 35,04
Fan power consumption 890mm kW 8,0 18,0 24,0 28,0
hp 11 24 33 38
890mm kW
hp
Fan drive ratio fan Ø890 1,01:1 ccw
Coolant capacity: engine liter 17
US gal 4,5
std. 0,8m² radiator with hoses liter 21
US gal 5,5
Coolant pump drive/ratio belt/1,41:1 cw
Coolant flow with standard system l/s 4,8 6,2 6,8 7,1
US gal/s 1,3 1,6 1,8 1,9
Minimum coolant flow l/s 2,1 2,5 2,5 2,7
US gal/s 0,6 0,7 0,7 0,7
Maximum outer circuit restriction incl. piping kPa 55,0
psi 8,0
Thermostat: start to open °C 82
°F 180
fully open °C 92
°F 198
Maximum static pressure head kPa 100
(expansion tank height + pressure cap setting) psi 14,5
Minimum static pressure head kPa 70
(expansion tank height + pressure cap setting) psi 10,2
Standard pressure cap setting kPa 75
psi 10,9
Maximum top tank temperature °C 107
°F 225
Recommended Draw down capacity.
The difference between min coolant level in the expansion tank and the lowest liter 2
level where the engine's coolant system still are functioning
US gal 0,5

4 / 19
Document No Issue Index
TAD1171VE
22294508 07
Charge air cooler system rpm 1400 1800 2000 2100
Heat rejection to charge air cooler IFN Power 265 kW kW 49 50 52 55
BTU/min 2787 2843 2957 3128
Charge air mass flow IFN Power 265 kW kg/s 0,37 0,42 0,44 0,46
IFN Power 265 kW

Charge air inlet temp. °C 174 165 164 169


(Charge air temp after turbo compressor) °F 345 329 327 336

See front page for important information


Max allowable Charge air outlet temp. °C 45 48 49 50
(Charge air temp after charge air cooler) °F 113 118 120 122

See front page for important information


kPa 12
Maximum pressure drop over charge air cooler incl. piping
psi 1,74
Charge air pressure kPa 204 179 171 172
(After charge air cooler) psi 29,59 25,96 24,80 24,95
Standard charge air cooler core area m² 0,8
foot² 8,61

Cooling performance: 0,8 m² radiator and 890 fan


Cooling air flow and maximum additional external restriction at different radiator air temperatures based on 107°C TTT
and 40% coolant. Valid at 1 atm.

Engine speed Engine


Air on temp Air flow External restriction
power
rpm hp °C °F m3/s ft3/s Pa psi
2100 265
(fix 1,01) 73 163 8,5 300,2 0 0,000
71 160 8 282,5 100 0,015
68 154 7,5 264,9 200 0,029

5 / 19
Document No Issue Index
TAD1171VE
22294508 07
Engine management system
Functionality Alternatives Default setting
Governor mode Isochronous
Droop Isochronous
Governor droop 10 127 Nm/rpm
Governor response Adjustable PI constants
Idle speed 600 900 rpm 700
If preheat is available, preheat will be
Request +
Preheating function Ignition Request active at ignition on if temp low or
temp
demanded by driver.
Ignition off stops engine Yes No No

Engine sensors and switch settings Engine protection action


Warning setting Alarm Optional
Parameter Unit Default
(Yellow) setting (Module or
Oil temp °C 125 130 Derate Shut down.
Oil pressure Low idle kPa 80 55,0 Shut down Shut down.
Rated speed kPa 300 275 Shut down Shut down.
Oil level Low level N/A Fault code only Fault code only
Piston cooling pressure
kPa Not avaliable on this engine
>1000 rpm
Coolant temp °C 105 107 Derate Shut down.
Coolant level N/A Low level Derate Shut down.
Fuel feed Low idle N/A Fault code only Fault code only
kPa See Fuel pressure limits
pressure Rated speed N/A Fault code only Fault code only
Water in fuel Alarm when closed N/A Fault code only Fault code only
EGR temp °C N/A N/A N/A N/A
Air filter pressure drop kPa 5 N/A Fault code only Fault code only
Altitude, above sea m N/A N/A Automatic derating, Automatic derating,
see section derating see section derating
Crank case pressure N/A Alarm at Shut down Shut down.
Charge air temp °C 120 125 Derate Shut down.
Charge air pressure kPa See Charge air pressure limits Derate Shut down.
SCR temp °C N/A N/A Automatic derating Automatic derating

Engine overspeed rpm 2400 N/A Fault code only Fault code only

Derated 0% to
Derated 100% to engine Forced idle after 5 Forced shut down
Derate parameters engine protection
protection map sec after 0 sec
map
Oil temp 130°C 132°C N/A N/A
Coolant temp 107°C 108°C N/A N/A
Charge air temp 125°C 126°C N/A N/A
EGR temp N/A N/A N/A N/A

Low oil pressure See Oil pressure limits N/A At alarm


Charge air pressure See Charge air pressure limits N/A N/A

6 / 19
Document No Issue Index
TAD1171VE
22294508 07
Electrical system
Voltage and type 24V
Alternator: output A 110/150
tacho output Hz/alternator rev. 6
drive ratio 5,25
Starter motor: type 90P55 / (105P70 ISS för start/stop)
output kW 5,5 / (7,0)
hp
Number of teeth on: flywheel 153
starter motor 11
Inlet manifold heater (at 20 V) kW 3
Power relay for the manifold heater A 1
Max wiring resistance main circuit mΩ 3

Conditions: Temperature °C 25 0 -15


(4 mΩ main circuit resistance@ Battery Ah / CCA 140/800 140/800 145 / 1050
Crank speed rpm 165 150 100
Crank current A 240 310 370
Starter input power during crank kW 5 6,1 6,3
Battery power during crank kW 5,3 6,5 6,8
Min battery @ 0°C Ah / CCA 140/800

7 / 19
Document No Issue Index
TAD1171VE
22294508 07
Power take off - Rear with Flywheel housing Standard rpm 1400 1800 2000 2100
Front end in line with crank shaft max:* Nm 1700 1370 1250 1200
(with a total added mass moment of inertia, J (mR2)≤0,05 kgm²) lbf ft 1254 1010 922 885
Front end belt pulley load. Direction of load viewed from max side kW 13 17 19 20
flywheel side: hp 18 23 26 27
Pulley diameter 201mm with distance 190mm from max down kW 13 17 19 20
main bearing 1 hp 18 23 26 27
max up kW 34 47 52 55
hp 46 64 71 75
Maximum torque on timing gear at rear PTO : * Nm 650
lbf ft 479
Speed ratio direction of rotation viewed from flywheel side 1,08:1/ ccw
Timing gear at compressor PTO max:* Nm 310
lbf ft 229
Speed ratio direction of rotation viewed from flywheel side 1,29:1 / ccw
Max allowed bending moment in flywheel housing Nm 7000
lbf ft 5163
Max. rear main bearing load N 3000
lbf 674,4

Power take off - Rear with Flywheel housing Twin PTO


Drive front LHS / RHS 1x11031509, 1" / 1x11031017, 7/8"
Drive rear 2x11031509, 1"
Pump flange 4xSAE B
Gear ratio engine / PTO 1:1,222
Max PTO power output: ** kW / rpm 135 / 2100
Torque used at max PTO power output: * Nm 616
lbf ft 454
Continous power output: *** kW 40,5
Torque used at 1200 rpm with allowed continuous power output Nm 322
lbf ft 237
Maximum torque on timing gear at rear PTO: * Nm 650
lbf ft 479
Speed ratio direction of rotation viewed from flywheel side 1,08:1/ ccw
Timing gear at compressor PTO max:* Nm 310
lbf ft 229
Speed ratio direction of rotation viewed from flywheel side 1,29:1 / ccw
Max allowed bending moment in flywheel housing Nm 7000
lbf ft 5163
Max. rear main bearing load N 3000
lbf 674,4
* Maximum allowed torque at individual PTO´s.
If more then one PTO output is used simultaniusly, calculations need to be performed to determine available maximum.
Available torque depends on application inertia.
** During maximum 5 seconds, 10 times/hour.
*** Maximum 20,25 kW per LHS PTO´s and RHS PTO´s. The difference in output load must not exceed 15 kW between
LHS PTO´s and RHS PTO´s.

8 / 19
Document No Issue Index
TAD1171VE
22294508 07

kW Power
300

250

200

150

100

50

0
0 500 1000 1500 2000 2500
rpm

IFN Power 265 kW

Nm Torque
2000
1800
1600
1400
1200
1000
800
600
400
200
0
0 500 1000 1500 2000 2500

rpm

IFN Power 265 kW

9 / 19
Document No Issue Index
TAD1171VE
22294508 07

Nm
Altitude derated Torque IFN Power 265
2000
1800
1600
1400
1200
1000
800
600
400
200
0
0 500 1000 1500 2000 2500
rpm

0m 1000m 1500m 2500m 3500 5000m

10 / 19
Document No Issue Index
TAD1171VE
22294508 07

Nm Engine protection map


1000
900
800
700
600
500
400
300
200
100
0
0 200 400 600 800 1000 1200 1400 1600

rpm

Max Torque Engine Protection Map R2

11 / 19
Document No Issue Index
TAD1171VE
22294508 07

g/kWh Smoke emission

0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
600 800 1000 1200 1400 1600 1800 2000 2200
rpm

IFN Power 265 kW

g/kWh
Fuel Consumption

230

225

220

215

210

205

200

195

190
600 800 1000 1200 1400 1600 1800 2000 2200

rpm

IFN Power 265 kW

12 / 19
Document No Issue Index
TAD1171VE
22294508 07

CAC P abs (kPa) Charge Air Pressure Limits

370

350

330

310

290

270

250
500 700 900 1100 1300 1500 1700 1900 2100 2300
rpm
Warning Level Alarm Level

Fuel P (kPa) Fuel Pressure Limits

350

300

250

200

150

100

50

0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
rpm
Warning Level

13 / 19
Document No Issue Index
TAD1171VE
22294508 07

Oil P abs (kPa) Oil Pressure Limits

350

300

250

200

150

100

50

0
0 500 1000 1500 2000 2500
rpm

Warning Level Alarm Level

14 / 19
Document No Issue Index
TAD1171VE
22294508 07

dB (A) Sound power level engine body


1/3 octave band analysis

120

110

100

90

80

70

60

50

40
20 31,5 50 80 125 200 315 500 800 1,25 2k 3,15 5k 8 12,5 20k

Frequency Hz
IFN Power
265 kW

dB(A) Sound power level


Total sound level at full load

124
122
120
118
116
114
112
110
108
106
104
102
100
98
96
0 500 1000 1500 2000 2500

rpm
IFN Power
265 kW

15 / 19
Document No Issue Index
TAD1171VE
22294508 07

Outer circuit
Outer circuit restriction versus coolant flow
restriction kPa
200
180
160
140
120
100
80
60
40
20
0
0 1 2 3 4 5 6 7 8 9 10

Outer circuit flow liter/s

Max outer circuit restriction Std. Cooling system restriction

1200 rpm Eng. speed 1500 rpm Eng. speed

1800 rpm Eng. speed 2200 rpm Eng. speed

2400 rpm Eng. speed 2600 rpm Eng. speed

dB (A) SCR Muffler transmission loss

60
55
50
45
40
35
30
25
20
15
10
31,5 63 125 250 500 1000

Frequency Hz

16 / 19
Document No Issue Index
TAD1171VE
22294508 07

Static Preassure kPa


HD-fan Ø 750mm Fan rpm=Fan ratio*Engine speed

3,000

2,500

2,000

1,500

1,000

0,500

0,000
0,0000 2,0000 4,0000 6,0000 8,0000 10,0000 12,0000
m³/s
2200 2000 1800 1600 1400 1200 fan rpm

HD-fan Ø 750mm
Fan rpm=Fan ratio*Engine speed
kW
35

30

25

20

15

10

0
0,0000 2,0000 4,0000 6,0000 8,0000 10,0000 12,0000 14,0000
m³/s
2200 2000 1800 1600 1400 1200

17 / 19
Document No Issue Index
TAD1171VE
22294508 07

Standard fan Ø 890mm Push 1,01:1


Static Preassure
kPa
4

3,5

2,5

1,5

0,5

0
0,0 2,0 4,0 6,0 8,0 10,0 12,0 14,0 16,0 18,0 20,0
m³/s
2200 2000 1800 1600 1400 1200

Standard fan Ø 890mm Push 1,01:1


kW
60,00

50,00

40,00

30,00

20,00

10,00

0,00
0,0 2,0 4,0 6,0 8,0 10,0 12,0 14,0 16,0 18,0 20,0
m³/s
2200 2000 1800 1600 1400 1200

18 / 19
Document No Issue Index
TAD1171VE
22294508 07
BSFC [g/kWh]

Fuel consumption [l/h]

19 / 19