GINLONG TECHNOLOGIES CO.,LTD.

S5-GC(50-60)K

Solis Three Phase Grid-Tied Inverters

Efficient Safe
• Max. efficiency 98.7% • IP66, C5 Anti-Corrosion Level
• String current up to 16A • Intelligent fan-cooling
• 5/6 MPPT design, supports multiple • Globally recognised branded componentry for
orientation system design longer life
• Night time PID recovery function, increases • AFCI protection, proactively reduces fire risk
overall system yield (optional)

Smart Economic
• Night SVG function • Supports GPRS/WiFi communication with less
• Supports export power control wiring and reduced installation costs
• Intelligent string monitoring, smart I-V • DC side supports "Y" connector
curve scan • 10/12 string inputs allow for 150%+ DC oversizing
• Scan to register on SolisCloud, supports
remote upgrade and control

Models:
S5-GC50K / S5-GC60K

360º View
www.solisinverters.com

DATASHEET S5-GC(50-60)K

Models 50K 60K


Input DC
Recommended max. PV power 75 kW 90 kW
Max. input voltage 1100 V
Rated voltage 600 V
Start-up voltage 195 V
MPPT voltage range 180 - 1000 V
Max. input current 5 × 32 A 6 × 32 A
Max. short circuit current 5 × 40 A 6 × 40 A
MPPT number / Max. input strings number 5 / 10 6 / 12
Output AC
Rated output power 50 kW 60 kW
Max. apparent output power 55 kVA 66 kVA
Max. output power 55 kW 66 kW
Rated grid voltage 3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated grid frequency 50 Hz / 60 Hz
Rated grid output current 76.0 A / 72.2 A 91.2 A / 86.6 A
Max. output current 83.6 A 100.3 A
Power factor > 0.99 (0.8 leading - 0.8 lagging)
THDi < 3%
DC injection current < 0.5% In
Efficiency
Max. efficiency 98.7%
EU efficiency 98.3%
Protection
DC reverse-polarity protection Yes
Short circuit protection Yes
Output over current protection Yes
Insulation resistance monitoring Yes
Residual current detection Yes
Surge protection DC Type II / AC Type II
Grid monitoring Yes
Anti-islanding protection Yes
Temperature protection Yes
Strings monitoring Yes
I/V Curve scanning Yes
Multi peak scan Yes
Integrated AFCI 2.0 Optional
Integrated PID recovery Optional (1)
Integrated DC switch Yes
General Data
Dimensions (W*H*D) 691 × 578 × 338 mm
Weight 53.7 kg
Topology Transformerless
Self-consumption (night) <1W
Operating ambient temperature range - 25 ~ +60°C
Relative humidity 0 - 100%
Ingress protection IP66
Noise emission (typical) < 55 dB(A)
Cooling concept Intelligent fan-cooling
Max. operation altitude 4000 m
Grid connection standard IEC 61683, IEC 60068, IEC 61727, IEC 62116, EN 50530, IS 16169/IS 16221(BIS)
Safety / EMC standard IEC 62109-1/-2, IEC 61000-6-1/-2/-3/-4
Features
DC connection MC4 connector
AC connection OT terminal (max. 70 mm²)
Display LCD
Communication RS485, USB, Optional: S3-WiFi-ST, S3-GRPS-ST

(1) Due to the similar functional logic, when the night time PID-Recovery function is integrated, the night time var compensation function
can not be used. Also, the negative grounding option is not available for inverters with night time PID-Recovery function.