constructive solutions

Technical Submittal

NITOPROOF 600
(Liquid applied single component elastomeric
waterproofing membrane)

Fosam Company Limited


Head Office
telephone: fax: email:
PO Box 11081
Jeddah – 21453 +966 (12) 637 5345 +966 (12) 637 5891 fosam@fosroc.com
Saudi Arabia
C.R. No. 31273
Paid up Capital: SR3,000,000
www.fosroc.com Registered Office: Industrial Area, Phase 4, Road No. 102, Street No. 82
constructive solutions

Technical Datasheet
Nitoproof 600 constructive solutions

Liquid applied single component elastomeric


waterproofing membrane

Uses
Nitoproof 600 is a low to medium viscosity grade
The high elasticity, excellent bond and low water permeability (approximately 600 poise) for roller, squeegee or spray
of Nitoproof 600 make it ideal for a wide range of application to horizontal and vertical surfaces.
water/vapour proofing applications such as foundations,
basements, tunnels, ground floors, suspended floors, car Nitoproof 600 HB is a high build grade (1000 poise minimum)
deck, bathroom and kitchen floors, roof terraces, balconies, for vertical surfaces, corner and edge detailing, cant
patios, bridges, precincts, inspection pits, water retaining formation and heavy applications.
structures (not potable water), sewage works, and inverted
roofs. The excellent chemical resistance of Nitoproof 600
makes it particularly suitable for tanking applications in areas Technical support
where aggressive ground water conditions prevail.
Fosroc offers a comprehensive range of high performance,
high quality repair, and maintenance and construction
Advantages products. In addition, Fosroc offers a technical support
package to specifiers, end-users and contractors, as well as
 One component; ready to apply direct from the can. on-site technical assistance in locations all over the world.

 Liquid application means details are simplified and there Properties


are no joints in the membrane.
Tack free time at 25oC: App. 2 hours
 Highly elastic, cures to give a permanently flexible Time to full cure at 25oC: App. 48 hours at 1.3 mm
resilient barrier over a wide range of temperatures. thickness

 Rapid installation; high build grade significantly reduces Cured membrane properties (at 14 day) at 25oC
time spent on preparatory works and detailing. Test Method Typical result
STD HB
 Excellent adhesion, can be applied to a wide range of Elongation (%) ASTM D412-83 800 535
substrates. Continuous adhesion prevents lateral Tensile strength
2
migration of water. (N/mm ) ASTM D412-83 1.9 2.0
Modulus at 100%
 Impervious - outstanding barrier properties ensure Elongation (N/mm2) ASTM D412-83 0.6 0.7
protection against corrosive soil conditions. Recovery from 200%
elongation (%) ASTM D412-83 95 95
Tear resistance (N) ASTM D624-73
 Thermally stable - irreversible chemical cure eliminates
Die B(ISO/R34) 9.0 12.0
melting and flow at high temperature.
Water vapour
transmission for
 Excellent resistance to oxidation and embrittlement. 1.3 mm film (g/m2/24 h) ASTM E96-80 9.7 9.9
Permeability: ASTM E96-80
 Available in two grades to meet all site requirements. (ng/m/PA/s)* 12
*ing = 10- kg 0.073 0.086
Shore ‘A’ hardness: ASTM D2240-86 30 39
 Mechanical damage to the membrane can be easily Aged hardness
repaired by spot application. (7 days at 70oC): ASTM D2240-86 37 44
Artificial weathering: No loss of
Standards compliance flexibility after
4000 hours
Nitoproof 600 meets the requirements of ASTM C836-84. exposure
Service temperature
o o
(continuous ambient): -40 C to 70 C
Description
Electrical properties
volume resistivity Standard HB
Nitoproof 600 single component pitch modified polyurethane 85 volts (ohm Cm): 42.6x10
9
42.6x109
cures by reaction with atmospheric moisture to give a tough 500 volts (ohm Cm): 42.6x10
9
42.6x10
9
elastomeric waterproof membrane. It is supplied in two
grades to meet all site application methods and
requirements.

Page 1
Nitoproof 600
Chemical properties Right angle bends

Nitoproof 600 grades are unaffected by a range of mild acids, All critical right angle bends must have a cant strip or coving
alkalis and water borne salts and is resistant to bio- details installed. This may be either performed or fabricated
deterioration. from Nitoproof 600 HB. If performed strip is used, it must be
bedded into a layer of Nitoproof 600 HB then given a
reinforcing pre-treatment by application of a 1.3 mm thick
Application instructions coat extending 150mm either side of the coving. Whilst still
wet, a 150mm wide strip of Nitoproof Scrim is embedded into
Preparation the Nitoproof 600 as reinforcement (ensure thorough
wetting). If Nitoproof 600 HB is used, it should be firmly
All surfaces to be waterproofed should be sound, clean and trowelled into the corner and formed into a 20mmx20mm
dry. triangular coving.

Concrete surfaces should have a light steel-trowel followed All other angles, joints, protrusions and stress points should
by a fine hair-broom or equivalent finish which is dry and free be pre-treated with a heavy application of Nitoproof 600 HB
of dust, oil and other contaminants. All high spots should be extending 50-100mm either side of the details.
removed.
Reinforcement with Nitoproof Scrim is recommended where
Moss and lichen must be removed physically followed by movement is possible.
treatment with fungicidal wash to kill any spores and inhibit
further growth. After treatment wash down thoroughly with Allow pre-treatment to cure overnight before general
clean water and allow to dry. application.

All metal surface should be made clean of paint, oils, rust and Application
other contaminants. Abrade to expose bright metal then wipe
clean with Fosroc Solvent 101* prior to priming. Nitoproof 600 should be applied by brush, trowel, roller,
squeegee or airless spray (two coat application for standard
Priming grade on vertical surfaces) at a minimum wet film thickness
2
of 1.3 mm (1.3 litre/m ). This is in addition to the preparatory
Priming is not normally required on good quality concrete work.
substrates. However, high absorbent surfaces such as
porous concrete, sand/cement and cement boards will The minimum application life (after opening the pack) is up to
require sealing to prevent absorption of Nitoproof 600. This 48 hours if stored in closed containers.
should be done using 1:1 mixture of Nitoproof 600 and
Fosroc Solvent 101. Use Nitoflor FC130 Clear as a primer for By use of the appropriate grade, the correct film thickness
bituminous surfaces and Fosroc Primer 4 for metal, glazed can be achieved in one pass. On a vertical surface using
and PVC surfaces. All metal and PVC surfaces should be standard grade, a film build of 1.3 mm is achievable in two
cleaned and abraded before priming. coats. Using HB grade, 1.3 mm is achievable in one coat. In
critical applications where surety of film thickness is
Movement joints paramount, two coats should be applied at right angles to
one another. Quantities per coat should be gauged to give
All expansion and movement joints should be sealed with the specified final film thickness.
Nitoseal 200 or Nitoseal 220 (or as per Fosroc representative
recommendations). When cured, Nitoseal Debonding Tape A short haired synthetic pile roller should be used if applying
should be applied to the top surface of the sealant and the by roller. For spray application, use a Graco King type pump
joint then over-coated with a 1.3 mm thick application of with 60:1 ratio at pressure 5.5 bar (80 psi), hose diameter
Nitoproof 600 extending 150mm each side of the tape. 13mm with a 10mm wip end. Tip size: 0.58mm - 0.84mm
Embed a 100 mm or 150 mm wide strip of Nitoproof Scrim, (23-33 thou).
then allow to cure before general application.
Nitoproof 600 HB should be applied by trowel or squeegee
Cracks (mainly vertical surface).

All shrinkage and non-moving structural cracks should be Where tiling above Nitoproof 600 is needed, a dust coat of
pre-treated with not less than a 1.3 mm coating of Nitoproof Nitoflor Anti-slip grains No. 3 can be applied while Nitoproof
600 extending 75mm either side of the crack. Allow to cure 600 is still wet, excess can be removed the following day.
overnight before general application.

constructive solutions Page 2


Nitoproof 600

constructive solutions Page 3


Nitoproof 600
Flood test
Storage
Prior to placement of protection, flood to a minimum depth of
50mm of water for 24 hours. Drains shall be plugged and
Shelf life
barriers placed to contain the water.
At least 9 months if stored in original unopened containers
Curing and protection
under normal warehouse conditions.
Nitoproof 600 membrane must be cured for a minimum of 24 Storage conditions
hours at 25oC before placing protection. Where damage to
the membrane is possible (by traffic, back-filling etc.) it o
Store in a cool dry place below 30 C.
should be protected by a cementitious screed or protection
boards. A dust coat of cement should be used to prevent
adhesion of the membrane to the boards. Where a bond Precautions
with the topping is not required, a separator sheet should be
used. Health and safety

All exposed areas of Nitoproof 600 should be coated with Some people are sensitive to resin systems. Gloves and a
Nitoproof Reflectacoat to ensure maximum resistance to barrier cream such as Kerodex Antisolvent, Rozalex
ultra-violet radiation. Antipaint or Debba-Wet-Work should be used when handling
these products. If contact with the resin occurs it must be
Cleaning removed before it hardens with a resin removing cream such
as Kerocleanse Standard Grade Skin cleanser or Rozaklens
Tools and equipment should be cleaned with Fosroc Solvent Industrial Skin cleanser. Follow by washing with soap and
101 immediately after use. Do not use the solvent for water. Do not use solvent. The use of goggles is
thinning except where a sealing coat is required. recommended but should accidental eye contamination
occur, wash thoroughly with plenty of water and seek
medical advice.
Limitations
For further information, refer to the Product Material Safety
Application should not commence if the temperature of the Data Sheet.
substrate is below 5oC.
Fire
Estimating
Nitoproof 600, Fosroc Primer 4, Nitoproof Reflectacoat and
Supply Fosroc Solvent 101 contain flammable solvents. Do not use
near an open flame or smoke during use.
Nitoproof 600: 20 litre pails
Nitoflor FC130 Clear: 5 kg pack Flash points
Nitoproof Reflectacoat: 5 and 25 litre containers o
Nitoproof Scrim: Nitoproof 600 & 600 HB: 45 C
100mm and 150mm width rolls o
Fosroc Primer 4: 10 C
Fosroc Primer 4: 1 litre packs o
Nitoproof Reflectacoat: 40 C
Fosroc Solvent 101: 5 and 25 litre containers o
Fosroc Solvent 101: 23 C
Coverage
For further information, refer to the Product Material Safety
Nitoproof 600: 2 Data Sheet.
1.3 litre/m (at 1.3 mm
thickness)
2
Nitoflor FC130 Clear: 5-7 m /litre
2
Fosroc Primer 4: 6-8 m /litre

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Telephone: +966 2 637 5345 Fax: +966 2 637 5891 email: fosam@fosroc.com
Head Office
Post Box 11081 Regional Offices
Jeddah Sales Office Tel: (02) 608 0999 Fax: (02) 638 0693 Yanbu Tel: (04) 322 4280 Fax: (04) 391 2980
Jeddah – 21453
Jeddah Showroom Tel: (02) 665 0187 Fax: (02) 667 4844 Makkah Tel: (02) 542 0869 Fax: (02) 542 0869
Saudi Arabia Riyadh Tel: (01) 482 9303 Fax: (01) 482 7562 Medinah Tel: (04) 855 0091 Fax: (04) 855 0047
Dammam Tel: (03) 864 0787 Fax: (03) 864 0758 Jubail Tel: (03) 362 3904 Fax: (03) 362 3875

www.fosroc.com Khamis Mushayt Tel: (07) 250 0469 Fax: (07) 250 0469 CSD Tel: (02) 608 0999 Fax: (02) 638 0693

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
Page 4 FO SA/NITOPROOF 600/10/04/12/C
constructive solutions

Material Safety
Datasheet
SAFETY DATA SHEET
1: IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY /
UNDERTAKING
Product Name: NITOPROOF 600 HB/S
Application: Elastomeric waterproofing memrane
Company: Fosam Company Limited
Address: Jeddah, Industrial Area, Phase 4, Road 414, Street 407, P.O. Box 11081, Jeddah
Telephone: (02) 637 5345 (4 Lines) Fax (02) 637 5891
2: COMPOSITION/INFORMATION ON INGREDIENTS
Composition: aromatic polyisocyanate, coal tar pitch, inert fillers, additives.
Hazardous Ingredient(s) Symbol Risk Phrases Other Information %
coal tar pitch T R46, 60, 61 Cas No:- - - - >50
cdiphenylmothane 4,4 Xn R20,36/37/38, 42 Cas No: 101-68-8 < 25
2toluene 2,4 di-isocyanate T R23,36/37/38, 42 Cas No: 584-84-9 < 0.25
All constituents of this product are listed in EINECS (European Inventory of Existing Commercial Chemical Substances)
or ELINCS (European List of New Chemical Substances) or are exempt.
Refer to Section 8 for Occupational Exposure Limits.
3: HAZARDS IDENTIFICATION
May cause cancer. Toxic, danger of serious damage to health
by prolonged exposure in contact with skin.
May cause sensitisatin by inhalation

TOXIC
4: FIRST AID MEASURES
Eyes: Irrigate immediately with copious quantities of water for several minutes.
Obtain medical attention urgently.
Skin: Wash immediately with copious quantities of water.
Hot contact - cool affected parts thoroughly under running water. Do NOT remove adhering material.
Cover burn with sterile dressing. Obtain medical attention immediately..
Inhalation: Remove from exposure, rest and keep warm and obtain medical attention urgently.
Ingestion: Wash out mouth with water and give sips of cold water to soothe the affected parts. Obtain medical
attention.

5: FIRE FIGHTING MEASURES


Suitable Extinguishing Media: Carbon dioxide, powder or foam.
Special Exposure Hazards: Toxic fumes. Chlorine compounds including hydrogen chloride. Nitrogen
compounds.
Special Protective Equipment: Self-contained breathing apparatus.
6: ACCIDENTAL RELEASE MEASURES
Personal Precautions: Wear rubber boots in addition to the recommended protective clothing.
Immediately issue NO SMOKING and NO NAKED FLAMES warnings.
Environmental Precautions: Prevent entry into drains, sewers and water courses.
Decontamination Procedures: Soak up with inert absorbent or contain and remove by best available means.
Dispose of as waste.

Issue No: 01 Date: 24.01.95 NITPROOF 600 HB/S Page: 1 of 4


7: HANDLING AND STORAGE
Handling: Maintain good standards of personal hygiene. Use only in well ventilated areas. Do not subject to
direct heat. Use only indirectly heated, oil-jacketted equipment. Care
should be taken to avoid contact with hot material. Avoid breathing fumes and vapours.
Storage: Store in cool, dry area. .
8: EXPOSURE CONTROLS/PERSONAL PROTECTION
Occupational Exposure Limits:- Hot material.
Substance 8 Hour TWA Source/Other Information
coal tar pitch volatiles. 14mgm-3 , Isocynates, all (as NCO) 0.02 mgm- (MEL) 0.07 MGM-3 EH40 Table 4
Engineering Control Measures: Use only in well ventilated areas. Local exhaust ventilatin is recommeded.
Personal Protective Equipment: A high standard of personal hygiene is essential. Avoid breathing vapours.
Avoid skin and eye contact. Wear heat resistant, impervious gloves. Face
shield. Change contaminated clothing immediately and clean before re-use.
Wash hands thoroughly after handling this product.
9: PHYSICAL AND CHEMICAL PROPERTIES
Physical State: Viscous liquid
Colour: Black.
Odour: Of pitch.
pH(concentrate): Not applicable (non-aqueous).

Flash Point (closed, °C): >100


EFlash point (closed, oC): > 100
Oxidising Properties: Not determined.
Relative Density (at 20°C): 1.3
Water Solubility: Insoluble

10: STABILITY AND REACTIVITY


Stability: Stable if used as directed.
Conditions to Avoid: Any source of ignition. Contaminatin with water
Materials to Avoid: Contaminatin by water. Oxides of caron, Sulphur compounds.
Hazardous Decomposition Products: Toxic fumes. Oxides of carbon. Sulphur compounds.
.
11: TOXICOLOGICAL INFORMATION
The following toxicological assessment is based on a knowledge of the toxicity of the product's components.
Health Effects
On Eyes: Irritating and may injure eye tissue if not removed promptly. Vapour causes irritation.
On Skin: May cause dermatitis and serious irreversible skin disorders on repeated or prolonged contact. Heated
material may cause burns.
By Inhalation: Low volatility makes inhalation unlikely at ambient temperatures. When heated emits fumes that
irritate the respiratory system.
By Ingestion: Low order of acute toxicity. May cause nausea, vomiting and diarrhoea.
Chronic: Repeated and prolonged contact, allied to poor personal hygiene practices may result in skin cancer.
This product contains quantities of polycyclic aromatic hydrocarbons (PCAs), some of which have
been shown by experimental studies to induce skin cancer. The inhalation of vapour, mist or fumes
over long periods may therefore be hazardous.

12: ECOLOGICAL INFORMATION


Environmental Assessment: When used and disposed of as intended, no adverse environmental effects are
foreseen.

Issue No: 01 Date: 24.01.95 NITOPROOF 600 HB/S Page: 2 of 4


Mobility: Solid. Insoluble in water.
Persistence and Degradability: Not readily biodegradable.
Bioaccumulative Potential: Not known.
Ecotoxicity: Expected to be ecotoxic to fish/daphnia/algae.
13: DISPOSAL CONSIDERATIONS
Disposal must be in accordance with local and national legislation.
Unused Product: Dispose of through an authorised waste contractor to a licensed site. Do not
empty into drains, sewers or water courses.
Used/Contaminated Product: As for Unused product.
Packaging: The method of disposal must be acceptable to the local authority.
14: TRANSPORT INFORMATION
UN Number: 3082
IMO: Class: 9 Packing Group: III Marine Pollutant: Yes
IATA/ICAO: Class: 9 Packing Group: III
ADR: Class: 9 Item: 11 (c)
Transport Name: Environmentally hazardous substance, liquid, nos (Coal Tar)
Hazchem/Kemler Code: 90
15: REGULATORY INFORMATION
Hazard Label Data:-
Named Ingredients: coal tar pitch, diphenylmethane 4,4 di-isocynate (isomers) toluene 2,6 di-isocyanate
UN Number: 3082
Symbol(s): T
Risk Phrases: May cause cancer.
Safety Phrases: Do not breathe vapour/spray.
Wear suitable protective clothing, gloves and eye/face protection.
Avoid exposure - obtain special instructions before use.
In case of accident or if you feel unwell, seek medical advice immediately (show the label
where possible).
Restricted to professional users.
EC Directives: Dangerous Substances Directive, 67/548/EEC and adaptations.
Dangerous Preparations Directive, 88/379/EEC.
Safety Data Sheets Directive, 91/155/EEC.
Carcinogens Directive, 90/394/EEC.
Statutory Instruments: Chemicals (Hazard Information and Packaging for Supply) (Amendment) Regs. 1996 (SI
1092).
Control of Substances Hazardous to Health Regs. 1994 (SI 3246).Environmental
Protection Act 1990.
Codes of Practice: Control of substances hazardous to health & control of carcinogenic substances (L5).
Waste Management. The Duty of Care.
Guidance Notes: Occupational skin diseases: health and safety precautions (EH 26).
Occupational exposure limits (EH 40).
The above publications are available from HMSO
16: OTHER INFORMATION
The data and advice given apply when the product is used for the stated application or applications. The product is not sold as suitable for any other
application. Use of the product for applications other than as stated in this sheet may give rise to risks not mentioned in this sheet. The product should
not be used other than for the stated application or applications without seeking advice from Fosroc Ltd.
If this product has been purchased for supply to a third party for use at work, it is the purchaser's duty to take all necessary steps to secure that any person
handling or using the product is provided with the information in this sheet.
It is the responsibility and duty of the employer to inform employees and others who may be affected of any hazards described in this sheet and of any
precautions which should be taken.
This sheet does not constitute or substitute for the users own assessment of workplace risk, as required by other health and safety legislation.
Further copies of this Safety Data Sheet may be obtained from Fosam Company Limited.

Issue No: 01 Date: 24.01.95 NITOPROOF 600 HB/S Page: 3 of 4


Date Printed: 04/01/1999 SDS Reference: 0849/NP600 HB/S

Issue No: 01 Date: 24.01.95 NITOPROOF 600 HB/S Page: 4 of 4


constructive solutions

Method Statement
method statement constructive solutions

Nitoproof 600
Section A : General Comments
Comments
High temperature working

It is suggested that, for temperatures above 350C, the following guidelines are adopted as
good working practice:

(i) Store unmixed materials in a cool (preferably temperature controlled) environment, avoiding
exposure to direct sunlight.
(ii) Keep equipment cool, arranging shade protection if necessary. It is especially important to
keep cool those surfaces of the equipment which will come into direct contact with the material
itself.
(iii) Try to avoid application during the hottest times of the day, arrange temporary shading as
necessary.
(iv) Make sufficient material, plant and labour available to ensure that application is a continuous
process.

Equipment
It is suggested that the following list of equipment is adopted as a minimum requirement.

Protective clothing : Protective overalls


: Good quality gloves, goggles and face mask

Preparation equipment : Stiff Wire Brush

Application equipment : Brush / trowel / squeegee / Graco spray

: Short hair synthetic pile roller

Application - points of note

Fosroc operates a policy to encourage the use, where possible, of approved or licensed applicators.
This ensures that repairs are completed satisfactorily so that the long term performance of the
materials is assured. For contractors who wish to apply the materials themselves Fosroc is also able
to offer technical assistance and training, either on-site or at its Training Centre in Jeddah.

Fosam Company Limited


Head Office telephone: fax: email:
PO Box 11081 +966 (2) 637 5345 +966 (2) 637 5891 fosam@fosroc.com
Jeddah – 21453
Saudi Arabia
Certificate number IND93024

www.fosroc.com
Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
constructive solutions

Section B : Application Method

1.0 Preparation

1.1 Clean all surfaces free of dust, laitance, foreign matter etc0., by stiff wire brushing. Oil and
grease should be cleaned using a chemical degreaser and wash with clean water and
allow to dry.

1.2 Remove all high spots from concrete surfaces and attain a light steeel-trowel followed by a
fine hair broom finish.

1.3 Remove moss and lichen manually and treat surface with a fungicide. Wash the surface
thoroughly with clean water and allow to dry.

1.4 Metal surfaces should be cleaned free of all paint, oils, rust and other contaminants. Abrade
the surface well to expose bright finish and wipe the surface with a cloth dipped in Fosroc
Solvent 102.

2.0 Priming

2.1 Normal sound & clean surfaces need not be primed.

2.2 Porous concrete substrates will have to be primed using a 1:1 mixture of Nitoproof 600 and
Fosroc Solvent 102.

2.3 Bituminous surfaces should be primed using Nitoprime 32.

3.0 Movement Joints

3.1 Seal all expansion and movement joints with Nitoseal 220 and allow to cure.
3.2 Apply Nitoseal Debonding Tape to the top surface of Nitoseal 220.

3.2 Overcoat the joint with 1.3 mm thick application of Nitoproof 600 which should extend 150
mm on each side of the debonding tape.

3.3 Allow the overcoating to cure before commencing general application.

4.0 Cracks

4.1 Treat all shrinkage and non-moving structural cracks with a 1.3 mm coating of Nitoproof 600
extending 75 mm on either side of the crack.

4.2 Allow the coating to cure overnight prior to commencing general application.

Page 2 of 4
constructive solutions

5.0 Right angle bends

5.1 Install a cant strip or coving detail on all right angle bends.

5.2 Form the cant strip or coving in either sand & cement or Plastijoint and it must be bedded into
a layer of Nitoproof 600. Follow it by a reinforcing pretreatment by application of a 1.3 mm
thick coat of Nitoproof 600 extending 150 mm on either side of the coving. Whilst wet,
embed a 150 mm wide strip of Nitoproof Scrim into the Nitoproof 600 as the reinforcement.

5.3 Allow the pretreatment to cure overnight prior to commencing general application.

6.0 Application

6.1 Apply Nitoproof 600 using a brush, trowel, squeegee or Graco spray pump.

6.2 The application of Nitoproof 600 should achieve the minimum d.f.t. as specified in the Data
Sheet.

6.3 On vertical surfaces, the film build of 1.3 mm is achievable in two coats. Apply the second
coat at right angle to the first.

7.0 Flood Test

7.1 Ensure that the membrane is fully cured before conducting the flood test.

7.2 Flood the surface to a minimum depth of 50 mm of water for a period of 24 hours.

8.0 Curing and Protection

8.1 Nitoproof 600 should be cured for a minimum of 24 hours before placing protection.

8.2 Apply a dust coat of cement on the cured membrane to prevent adhesion to the board.

8.3 Coat all exposed areas of Nitoproof 600 with Nitoproof Reflectacoat, to ensure maximum
resistance to UV radiation.

9.0 Cleaning

9.1 Clean all tools and equipment with Fosroc Solvent 102, immediately after use.

Page 3 of 4
constructive solutions

Section C : Approval and variations

This method statement is offered by Fosroc as a ‘standard proposal’ for the application of Nitoproof
600. It remains the responsibility of the Engineer to determine the correct method for any given
application.

Where alternative methods are to be used, these must be submitted to Fosroc for approval, in
writing, prior to commencement of any work. Fosroc will not accept responsibility or liability for
variations to the above method statement under any other condition.

Page 4 of 4
constructive solutions

Test Reports
constructive solutions

th
Date: 8 May 2013
Ref: W-0513-LEED-N600

To Whom It May Concern


Product:

Nitoproof 600 (Liquid applied single component elastomeric waterproofing membrane)

Nitoproof 600 is a single component pitch modified polyurethane cures by reaction with atmospheric moisture
to give a tough elastomeric waterproof membrane. It is supplied in two grades to meet all site application
methods and requirements.

Nitoproof 600 satisfies the LEED requirements for VOC limitations and can contribute to earn Indoor Air
Quality Credit 4.1: Low Emitting Materials, Adhesives & Sealants, which is intended to reduce quantity of
indoor contaminates that are odorous, potentially irritating and/or harmful to the comfort and well-being of
installers and occupants.

For credit, the following information is advised:

Product Name Volatile Organic Compound (VOC)

Fosroc Nitoproof 600 < 30 gr/liter

Please refer to MSDS of above-mentioned product for more details on health and safety.

For more information, please don’t hesitate to contact the undersigned.

Sincerely,

Saleh Alawi
Technical Services Manager
Fosam Company Limited (Saudi Fosroc)

® ®
“USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used with permission”

Fosam Company Limited


Head Office
telephone: em ail:
PO Box 11081
Jeddah – 21453 +966 (2) 637 5345 fosam@fosroc.com
Saudi Arabia
C.R. No. 31273 Certificate number IND 93024

Paid up Capital: SR3,000,000


www.fosroc.com Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
constructive solutions

Job References
Job References for Nitoproof 600 (Fosroc Saudi Arabia)
sorted by ascending Project Category and ascending Project Date
Main Contractor, Project
Project Category Project Title, (Client) Product Application Quantity Site Location (Subcontractor) Specifier/ Consultant Date
Building- Commercial- DOKAAE, (Saudi Binladin Pods Waterproofing 200 Pails Makkah Saudi Binladin Saudi United May-04
Hotel Group) Group, (Saudi Waterproofing
Binladin Group)
Building- Commercial- Al-Amoudi Building, (Al- Waterproofing 3000 Kgs Makkah Al-Amoudi Group Saudi Lab Aug-03
Shops Amoudi Group)
Building- Commercial- Ghornatah oasis, (GOSI) adhesive ,anchor and 10 pails Riyadh LATCO Al Omranyah Aug-11
Shops grout ,waterproofing
,repairing
Building- Commercial- IMPROVEMENT OF AL waterproofing 800 pails Jeddah SAUDI BIN LADEN, Dar Al Riyadh Jan-05
Stadia HAJJ TERMINAL, (King (HARAMAIN GATE)
Abdul Aziz International
Airport)
Building- Education- Home Ownership Phase 2, Grouting and Sealing 120 Packs North Dammam C.C.E., (N/A) Dar Al-Handasa Oct-05
School (Aramco - KJO)
Building- Education- Princess Noura University Waterproofing for the 10000 Kg Riyadh SBG-ABCD, Dar Al Handasa Jan-09
University For Women, (Ministry of precast Toilets (SACODECO)
Education)
Building- Housing- DOCTORS HOUSING WATER PROFFING 500 Yanbu AZMAEEL AL-RABIAH Oct-09
Houses PHASE 1, (Royal Kilogram(s) Contracting & CONSULTANTS
Comission) Construction CO.
Building- Industrial- Public Work - Hofuf, Sealant, Coating and 10 Units Hofuf Villa est Feb-08
Factory (Private) waterproofing
Building- Industrial- SCECO Repair Work, water proofing/grout 50 Hassa Abdul WahidAl SEC May-09
Power Station (SEC) Kilogram(s) Moalin Co
Building- Leisure- Olaya Twin Towers, (GOSI) WATER PROOFING 215 Packs Riyadh Nesma Contracting Zuhair Fayaz Consult Mar-11
Complex Co

12/18/2011 Page 1 of 1
constructive solutions

Approvals
constructive solutions

Case Histories
CASE STUDY : DAR AL QABLAH constructive solutions

• Projec : Dar Al Qablah Complex


Madinah

• Client : Executive Committee for


the development of the central region
in Medina

• Consultant : Zuhair Fayiz

• Contractor : Saudi Bin Ladin Group

• Sub Contractar: Al Ameel E.S.T

• Location : Central Area - Madinah


Saudi Arabia

• Products : Nitoflor TF10000


Nitoproof 600
• Execution :January, 2009
Date

PProject Background

This is new big Hotel in madinh and have many


Mechanical and service rooms need to heavy
duty epoxy resin floor screed system with high
compressive strength.
And also it have many small bathroom and the
specification of waterproofing system is
membrane but this system will made many
problem because the bathrooms have many
drainage pipe and the contact between the pipes
and the membrane it will very week on over lap
welding.
.
Fosroc Solutions
Fosroc has the solutions for all Problems through
wide range of our products .
We proposal about Mechanical and service room
Nitoflor TF10000 Heavy duty epoxy resin floor
screed.
Total quantity Of Nitoflor Tf10000 has been
used 2900 Pack/35 Kg
We proposal about small bathroom
Nitoproof 600 liquid applied single component
elastomeric waterproofing membrance
Total quantity of Nitoproof 600 has been used
700 Pail /25 Kg

Fosam Company Limited

Jeddah Sales Office telephone: fax: e-mail:


P.O. Box 11081 00 966 2 6920565 00 966 2 6823625 fosam@fosroc.com
Jeddah - 21453
C.R. No. 31273
Paid up Capital: SR3,000,000
www.fosroc.com Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
PROJECT Madinah Haram

*Applay Nitoflor TF10000 on floor after paint Nitoprime 31 * Nitoflor TF10000 Must Raked to required thicknees

*Apply the first coat from Nitofloor Fc145 * Apply the second coat from Nitofloor Fc145

• Bathroom after applied Nitoproof 600

Fosam Company Limited

Jeddah Sales Office telephone: fax: e-mail:


P.O. Box 11081 00 966 2 6920565 00 966 2 6823625 fosam@fosroc.com
Jeddah - 21453
C.R. No. 31273
Paid up Capital: SR3,000,000
www.fosroc.com Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407

You might also like