25W Single Output Switching Power Supply EPS-25 series
User’s Manual
■ Features :
Universal AC input / Full range
High efficiency up to 90%
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
3"×2" compact size
LED indicator for power on
No load power consumption<0.3W
3 years warranty
■ GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx Bauar t gepruft
Sicherheit
egel ma ge
od o s
be wac g
SPECIFICATION
www. tuv.com
ID 2000000000
UL62368-1 BS EN/EN62368-1 GB4943.1 TPTC004 IEC62368-1
MODEL EPS-25-3.3 EPS-25-5 EPS-25-7.5 EPS-25-12 EPS-25-15 EPS-25-24 EPS-25-27 EPS-25-36 EPS-25-48
DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 27V 36V 48V
RATED CURRENT 5A 5A 3.4A 2.1A 1.7A 1.05A 0.95A 0.7A 0.53A
CURRENT RANGE 0 ~ 5.5A 0 ~ 5.5A 0 ~ 3.74A 0 ~ 2.34A 0 ~ 1.87A 0 ~ 1.17A 0 ~ 1.05A 0 ~ 0.78A 0 ~ 0.59A
RATED POWER 16.5W 25W 25.5W 25.2W 25.5W 25.2W 25.65W 25.2W 25.44W
PEAK LOAD(10sec.) Note.6 18.15W 27.5W 28.05W 28.08W 28.05W 28.08W 28.35W 28.08W 28.32W
RIPPLE & NOISE (max.) Note.2 60mVp-p 60mVp-p 80mVp-p 100mVp-p 100mVp-p 180mVp-p 180mVp-p 200mVp-p 240mVp-p
OUTPUT
VOLTAGE ADJ. RANGE 3.1 ~ 3.6V 4.75 ~ 5.5V 7.13 ~ 8.25V 10.8 ~ 13.5V 13.5 ~ 16.5V 21.6 ~ 27V 24.3 ~ 29.7V 32.4 ~ 39.6V 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 50ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 79% 81% 83% 86% 87% 88% 89% 89% 90%
INPUT
AC CURRENT (Typ.) 0.6A/115VAC 0.4A/230VAC
INRUSH CURRENT (Typ.) COLD START 35A/230VAC
LEAKAGE CURRENT <1mA/240VAC
115 ~ 170% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION 3.7 ~ 4.6V 5.6 ~ 6.75V 8.63~ 10.5V 14 ~ 17V 17.25 ~ 20.25V 27.6 ~ 32.4V 31.05 ~ 36.45V 39.7 ~ 46.8V 53.3 ~ 64.8V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP. -30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
OPERATING ALTITUDE Note.8 2000 meters
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, CCC GB4943.1,EAC TP TC 004 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
(Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, GB9254.1 Class B,GB17625 Class A,EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020
MTBF 3830.1K hrs min. Telcordia SR-332 (Bellcore) ; 655.4K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 76.2*50.8*24mm (L*W*H)
PACKING 0.081Kg; 120pcs/10.7Kg/0.94CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
NOTE
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
6. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
7. EPS-25-15/24/27/36/48 without Hs1.
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:EPS-25-SPEC 2024-01-26
25W Single Output Switching Power Supply EPS-25 series
Mechanical Specification Unit:mm
76.2
3.175
69.85
3.175
FS1
AC FUSE
T2A/250V HS1
LED
3
44.45
2
50.8
1 CN2
CN1 1
2
SVR1
4-ψ3.2
24
3 max.
AC Input Connector (CN1) : JST B3P-VH or equivalent DC Output Connector (CN2) : JST B2P-VH or equivalent
Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal
1 AC/N 1 -V JST VHR JST SVH-21T-P1.1
JST VHR JST SVH-21T-P1.1 or equivalent or equivalent
2 No Pin or equivalent or equivalent 2 +V
3 AC/L
HS1(Note.7) must have safety isolation distance with system case.
: Grounding required
Block Diagram
fosc : 100KHz
EMI FILTER POWER RECTIFIERS +V
I/P & &
SWITCHING -V
RECTIFIER FILTER
DETECTION
FG
CIRCUIT
O.L.P. CONTROL
O.V.P.
Output Derating Static Characteristics
100
100
90
80
80
60 70
50
LOAD (%)
LOAD (%)
60
40
50
20
40
-30 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 95 100 115 120 140 160 180 200 220 240 264
AMBIENT TEMPERATURE (℃) INPUT VOLTAGE (V) 60Hz
File Name:EPS-25-SPEC 2024-01-26