Clinical Chemistry Family
> Intelligent solutions for small to large laboratories
> Broad product range from one source
> Validated applications and settings for arumamed
reagents
GL-640
PT. ARDIKHA UMRAN ABADI
Email: info@ardikha.co.id
Address: Jl. Bintara Vll No 100A RT006/
RW 003 Bintara, Bekasi - Jawa Barat
Range of Instruments
Suitable solutions for a wide range of laboratories
Arumamed GL-640
Automatic Chemistry Analyzer
>
For entry level up to
high throughput demands
4500 to 6000 tests / month
Assay Settings Arumamed GL-280
> Preprogrammed method database
> Validated for photometers,
analyzers and systems
3000 to 4500 tests / month
Reagents
>
Multipurpose and system reagents
>
Multiple kit sizes
>
Ready to use
Arumamed GL-220
>
Excellent stability
Control Material 1500 to 3000 tests / month
> Internal quality control
> Accuracy and precision testing
Arumamed GL-100
Semi-auto Chemistry Analyzer
>
Small laboratories Up to 500 tests / month
> Backup solution
GLENBIO BARCODED SYSTEM REAGENTS
STANDARD /
PRODUCT CATALOGUE CODE R1 R2
CALIBRATOR
A-1-ANTITRYPSIN GL6S109 2x45ml 1x19ml ---
ACE GL6S309 4x42ml --- ---
ACETAMINOPHEN GL6S509 3x44ml 3x22ml ---
ADA GL6S947 2x20ml 2x10ml 2 x (1x1ml)
ALBUMIN BCG GL6S307 5x47ml --- 1x5ml
ALP GL6S711 4x42ml 2x17ml ---
ALT GL6S702 4x42ml 2x17ml ---
AMYLASE GL6S103 4x42ml --- ---
AMMONIA GL6S1007 4x42ml 2x17ml ---
ASO GL6S408 2x21ml 1x17ml ---
AST GL6S703 4x42ml 2x17ml ---
BICARBONATE (CO2) GL6S1101 4x21ml --- ---
BILIRUBIN DIRECT GL6S205 5x42ml 2x21ml ---
BILIRUBIN TOTAL GL6S245 5x42ml 2x21ml ---
C3 GL6S807 5x42ml 2x21ml ---
C4 GL6S808 5x42ml 2x21ml ---
CALCIUM GL6S102 5x46ml --- 1x5ml
CERULOPLASMIN GL6S1102 2x20ml 2x5ml ---
CHOLESTEROL GL6S704 5x46ml --- 1x5ml
CHOLINESTERASE GL6S1001 4x42ml 2x17ml ---
CK-MB GL6S805 4x42ml 2x17ml ---
CK-NAC GL6S804 4x42ml 2x17ml ---
CREATININE JAFFE GL6S236 4x42ml 2x17ml 1x5ml
CREATININE ENZYMATIC GL6S226 4x42ml 4x21ml ---
CRP GL6S304 5x42ml 2x17ml ---
CYSTATIN C GL6S1103 4x20ml 2x8ml ---
FERRITIN GL6S502 2x42ml 2x30ml ---
FRUCTOSAMINE GL6S1002 4x42ml --- ---
GAMMA GT (GGT) GL6S705 4x42ml 2x17ml ---
GLUCOSE HEX GL6S706 4x42ml 2x17ml 1x5ml
GLUCOSE PAP GL6S716 5x42ml --- 1x5ml
HAPTOGLOBIN GL6S108 2x45ml 1x19ml ---
HbA1c GL6S2201 1x17ml 1x10ml ---
HBDH GL6S708 4x42ml 2x17ml ---
HDL CHOLESTEROL DIRECT GL6S612 2x45ml 2x15ml 1x1ml
HsCRP GL6S314 2x45ml 1x19ml ---
IgA GL6S606 5x42ml 2x21ml ---
IgG GL6S607 5x42ml 2x21ml ---
IgM GL6S608 5x42ml 2x21ml ---
IRON FERROZINE GL6S301 4x42ml 2x17ml ---
LACTATE GL6S1008 5x46ml --- ---
LDH (L-P) GL6S709 4x38ml 3x20ml ---
LDH (P-L) GL6S719 4x42ml 2x17ml ---
LDL CHOLESTEROL DIRECT GL6S605 2x45ml 2x15ml 1x1ml
LIPASE GL6S507 4x20ml 2x8ml ---
LITHIUM GL6S1106 2x20ml 2x10ml ---
Lp(a) GL6S409 2x45ml 1x19ml ---
MAGNESIUM GL6S207 5x47ml --- ---
MICROALBUMIN GL6S501 4x42ml 2x17ml 2 x (2x2ml)
PANCREATIC AMYLASE GL6S1009 4x42ml 2x17ml ---
STANDARD /
PRODUCT CATALOGUE CODE R1 R2
CALIBRATOR
PHOSPHORUS GL6S209 5x47ml --- ---
PREALBUMIN GL6S106 1x42ml 1x17ml ---
RF GL6S518 2x47ml 1x19ml ---
SALICYLATE GL6S506 4x42ml 2x17ml ---
TOTAL PROTEIN GL6S306 5x47ml --- 1x5ml
TRANSFERRIN GL6S305 2x45ml 1x19ml ---
TRIGLYCERIDES GL6S801 5x47ml --- 1x5ml
UREA GL6S802 5x42ml 2x21ml 1x5ml
URIC ACID GL6S803 4x42ml 2x17ml 1x5ml
URINARY PROTEIN GL6S303 5x42ml 4x21ml ---
ZINC GL6S505 4x42ml --- ---
E-LIMS
Laboratory Information Management System
Solution to improve your Laboratory with Designed to streamline clinical laboratory operations
• Fully Barcode System
• Multi User Client Workstation
• Multi Connection Interfacing Instrument
• Android Mobile Support Needed
GL-640
Auto Chemistry Analyze
GL-640
General information Reaction unit
Machine type Random access, open reagent & locked reagent Reaction
action tray 90 reaction cuvettes, new amorphous optical plastics reaction
Test speed 400 photometric tests/hour (Mono or double reagent) cups, perfect transmittance.
Test principle 640 test/hour with ISE Reaction volume 150μl-330μl
Test method Colorimetric method, turbidimetry Reaction time 10 minutes
1 point end, 2 point end, Fixed-Time, Kinetics Temperature Peltier pad incubation system, reaction temperature
Linear & nonlinear
Calibration type (37℃ ± 0.1 ℃)
Sample unit Optical system
Sample tray 120 sample potitions Light source Halogen lamp
Sample tube Micro cup & test tube & blood collection tube can be used. Wavelength 340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm;
( Φ 12 -13 )mm * ( 25 – 100 )mm 700nm(4 more options)
Sample volume 2-30μL, step by 0.1μL Absorbance range 0-4.0 Abs
Sample probe Liquid surface detection, timely tracking for liquid volume. Resolution 0.0001 Abs
Collision avoidance Operating system
Sample barcode Sample barcode reader Operation system Windows XP, Windows 7, Windows 8, Windows 10
Reagent unit Data processing Automatic calibration, test combination, effective time
Reagent tray 90 reagent positions , Non-stop cooling system with peltier management of reagents, serum index, whole process de-
pad inside, 24 hours 2℃-14℃, open system, could accept tection, linear expansion of enzyme, blank deduction,dirty
any reagent. cuvette memory , cross infection prevention, patient info-
Reagent volume 20-300μl, step by 1μl rmation memory and association input, automatic report
Reagent
agent needle Liquid surface detection, timely tracking for liquid volume audit, data fuzzy query, report statistics and printing, refe-
Collision avoidance. rence range grading, alarm information classification, user
Regent barcode Regent barcode reader operation privilege classification management.
Report
port printing 6 formats optional, support custom pattern
Working conditions
interface TCP/IP network interface
Power supply AC 220V, 50Hz;AC 110V,50/60Hz, 1000VA
Mixing system
Water consumption 15L/hour(maximum)
Mixer paddle-type mixing, effective reducing of carry-over
Dimension 1100mm * 765mm * 1150mm(L*W*H)
Weight 165Kg
GL-280
Auto Chemistry Analyzer
GL-280
General information Mixing system
Machine type Random access, open reagent & locked reagent Mixer paddle-type mixing, effective reducing of carry-over
Test speed Constant 200 tests/hour (Mono reagent or double reagent) Optical system
Test principle Colorimetric method, turbidimetry Light source Halogen lamp
Test method 1 point end, 2 point end, Fixed-Time, Kinetics Wavelength 340nm; 405nm; 450nm; 505nm; 546nm; 578nm;
Calibration type
Calibrat Linear & nonlinear 630nm; 700nm(4 more options)
Sample unit Absorbance range 0-4.0 Abs
Sample tray 40 sample positions Resolution 0.0001 Abs
Sample tube Micro cup & test tube & blood collection tube can be used.
Operating system
( Φ 12 -13 )mm * ( 25 – 100 )mm
Operation system Windows XP, Windows 7, Windows 8, Windows 10
Sample volume 2-30μL, step by 0.1μL
Data process
processing Automatic calibration, test combination, effective time
Sample probe Liquid surface detection, timely tracking for liquid volume.
management of reagents, serum index, whole process de-
Collision avoidance linear expansion of enzyme, blank deduction,dirty cuvette
Sample barcode Sample barcode reader memory , cross infection prevention, patient information
Reagent unit memory and association input, automatic report audit, data
Reagent tray 80 reagent positions (40 for R1 & 40 for R2), Non-stop cooling fuzzy query, report statistics and printing, reference range
grading, alarm information classification, user operation
system with peltier pad inside, 24 hours 2℃-14℃, open system,
privilege classification management.
could accept any reagent.
Report
port printing
printin 6 formats optional, surpport custom
Reagent volume 20-300μl, step by 1μl
pattern
Reagent
agent needle
ne Liquid surface detection, timely tracking for liquid volume.
interface TCP/IP network interface
Collision avoidance.
Regent barcode Regent barcode reader Working conditions
Power supply AC 220V, 50Hz;AC 110V,50/60Hz, 1000VA
Reaction unit
Water consumption 8 L/hour (maximum)
Reaction
action tray The reaction tray is single circle, with a total of 44
Dimension 745mm*540mm*530(L*W*H)
semi-permanent plastic cuvettes
Weight 50Kg
Reaction volume 150μl-330μl
Reaction time 10 minutes
Temperature Peltier pad incubation system, reaction temperature (37℃
± 0.1 ℃)
GL-220
Auto Chemistry Analyzer
General information
Machine type Random access, open reagent & locked reagent Reaction volume 150μl-330μl
Test speed Constant 150 tests/hour (Mono reagent or double reagent) Mixing system
Test principle Colorimetric method, turbidimetry Mixer paddle-type mixing, effective reducing of carry-over
Test method 1 point end, 2 point end, Fixed-Time, Kinetics
Optical system
Calibration type
Calibrat Linear & nonlinear
Light source Halogen lamp
Sample unit
Wavelength 340nm; 405nm; 450nm; 505nm; 546nm; 578nm;
Sample tray 40 sample positions
630nm; 700nm(4 more options)
Sample tube Micro cup & test tube & blood collection tube can be used.
Absorbance range 0-4.0 Abs
( Φ 12 -13 )mm * ( 25 – 100 )mm
Resolution 0.0001 Abs
Sample volume 2-30μL, step by 0.1μL
Operating system
Sample probe Liquid surface detection, timely tracking for liquid volume.
Operation system Windows XP, Windows 7, Windows 8, Windows 10
Collision avoidance
Data process
processing Automatic calibration, test combination, effective time
Sample barcode Sample barcode reader
management of reagents, serum index, whole process de-
Reagent unit
linear expansion of enzyme, blank deduction,dirty cuvette
Reagent tray 80 reagent positions (40 for R1 & 40 for R2), Non-stop cooling memory , cross infection prevention, patient information
system with peltier pad inside, 24 hours 2℃-14℃, open system, memory and association input, automatic report audit, data
could accept any reagent. fuzzy query, report statistics and printing, reference range
Reagent volume 20-300μl, step by 1μl grading, alarm information classification, user operation
Reagent
agent needle
ne privilege classification management.
Liquid surface detection, timely tracking for liquid volume.
Collision avoidance. Report
port printing
printin 6 formats optional, surpport custom
Regent barcode Regent barcode reader pattern
interface TCP/IP network interface
Reaction unit
Reaction
action tray 44 reaction cuvettes, new amorphous optical Working conditions
plastics reaction cups, perfect transmittance. Power supply AC 220V, 50Hz;AC 110V,50/60Hz, 1000VA
Reaction time Water consumption 6 L/hour (maximum)
10 minutes
Temperature Dimension 750mm*560mm*535(L*W*H)
Peltier pad incubation system, reaction temperature (37℃
Weight 50Kg
± 0.1 ℃)
GL-100
Semi-Auto Chemistry Analyzer
Test method 1 point end, 2 point end (Sample blank), Kinetics, Fixed-time, Coagulation
Optics 7 standard filters: 340nm, 405nm, 450nm, 505nm, 546nm, 578nm, 630nm. 2 more for optional.
Lamp house Long-life tungsten halogen lamp ( 6V/10W ) , auto-sleep function.
Display 7.0” TFT LCD with touch screen, 800*480 pixels.
Printer Build-in thermal printer, 57mm printer paper.
Temperature 25, 30, 37℃ and Room temperature. By means of Peltier elements.
Flow cell capacity & optical path 32μl, 10mm.
Resolution 0.0001 Abs.
Photometric range 0.0000-4.0000 Abs.
CPU ARM Cortex-A8,800MHz
Memory (Storage) 4 GB.
Interface Over 300 programs, 200000 results can be stored.
4 USB Hosts, 1 USB Slave, 1 Ethernet port.
USB port ( host ) for keyboard, mouse, printer, U disk, bar code reader etc.
USB port ( slave ) for PC connection(support PC software control function).
Operational environment Temperature: 10℃~30℃, Humidity: 30%~80%.
Power requirement Wide power supply AC 100-240V, 50/60 Hz.
Dimension 420*340*202mm (L *W*H )
Weight 4.45Kg
A-Lyte 500
Electrolyte Analyzer
Throughput Printer
100 Samples / Hour Built-in thermal printer, Support external printer
Parameters Interface
K, Na, Cl, iCa, tCa, Li, pH, Mg RS-232, LAN, USB
LIS Connectivity
Calibration
One-Point And Three-Points Data Storage
50.000 Results
Sample Types
Whole Blood, Serum, Urin (Diluted), Other Reagent Management
Closed system, real-time reagent volume display
Sample Volume
80uL Dimention
Device: 330x235x439
Auto Loader (Optional) Auto Loader: 245x230x125
32 Sample Potitions, includin 3 for QC,5 for STAT
Build in bar-code scanner Weight
Device: 7.5Kg
Electrolyte Reagents Auto Loader: 2.0 Kg
All-in-one reagent pack
Urin dilutor Other
3 level QC Working temprature: 15 - 30 C
Humidity: 20% - 80%
Display Power Supply: AC100 -240V , 50-60Hz, 200VA
7-inch color Touch screen
Combination
Performance
7
Mg