PARKING SPACE

S2W
OFFICE S2W
1 T&B
S2
S2 S1
S2
S2 S2

PARKING SPACE
(BASEMENT) COMMERCIAL SPACE
(FIRST FLOOR)
SLOPE @ 2:13.5
RAMP UP

SLOPE @ 2:13.5
EARTH FILL RAMP UP

PARKING LIGHTING LAYOUT


SCALE: 1:100
FIRST FLOOR LIGHTING LAYOUT
SCALE: 1:100

PROFESSIONAL ELECTRICAL ENGINEER: CADD BY: REVISIONS : PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO:

THREE (3) STOREY RESIDENTIAL &


COMMERCIAL BUILDING WITH BASEMENT

PROJECT LOCATION:
DANIELLE SHAE DUCUSIN GALACGAC
AS SHOWN
E-1
PRC REG. NO. :
VALIDITY :
PTR NO. :
PLACED ISSUED : 11 23
TERRACE
TERRACE

S1 S1

LIVING S2 S2 S1
S2W
AREA
BEDROOM OFFICE
1 S1

S1

S1 S1 S1

S1
S2 4 S2
S2
S1
S2
KITCHEN

MASTER'S
BEDROOM TERRACE
DINING
AREA

S1
S1

TERRACE

SECOND FLOOR LIGHTING LAYOUT


SCALE: 1:100
THIRD FLOOR LIGHTING LAYOUT
SCALE: 1:100

PROFESSIONAL ELECTRICAL ENGINEER: CADD BY: REVISIONS : PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO:

THREE (3) STOREY RESIDENTIAL &


COMMERCIAL BUILDING WITH BASEMENT

PROJECT LOCATION:
DANIELLE SHAE DUCUSIN GALACGAC
AS SHOWN
E-2
PRC REG. NO. :
VALIDITY :
PTR NO. :
PLACED ISSUED : 12 23
7
PARKING SPACE

S2W

WATER
TANK

STORAGE
S1

PARKING SPACE
(BASEMENT)

SLOPE @ 2:13.5
RAMP UP
EARTH FILL

ROOF DECK LIGHTING LAYOUT


SCALE: 1:100
BASEMENT POWER LAYOUT
SCALE: 1:100

PROFESSIONAL ELECTRICAL ENGINEER: CADD BY: REVISIONS : PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO:

THREE (3) STOREY RESIDENTIAL &


COMMERCIAL BUILDING WITH BASEMENT

PROJECT LOCATION:
DANIELLE SHAE DUCUSIN GALACGAC
AS SHOWN
E-3
PRC REG. NO. :
VALIDITY :
PTR NO. :
PLACED ISSUED : 13 23
TERRACE

OFFICE S2W
T&B

ACU
BEDROOM 1
LIVING
AREA
COMMERCIAL
SPACE
WH
WH

OVEN
SLOPE @ 2:13.5

KITCHEN
(FIRST FLOOR) ACU

MASTER'S
BEDROOM DINING
AREA

REF
ACU

TERRACE
RAMP UP

FIRST FLOOR POWER LAYOUT


SCALE: 1:100
SECOND FLOOR POWER LAYOUT
SCALE: 1:100

PROFESSIONAL ELECTRICAL ENGINEER: CADD BY: REVISIONS : PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO:

THREE (3) STOREY RESIDENTIAL &


COMMERCIAL BUILDING WITH BASEMENT

PROJECT LOCATION:
DANIELLE SHAE DUCUSIN GALACGAC
AS SHOWN
E-4
PRC REG. NO. :
VALIDITY :
PTR NO. :
PLACED ISSUED : 14 23
TERRACE

S2W
S1

WATER
OFFICE S2 S1 TANK
S2W

STORAGE

ACU

TERRACE

ACU

THIRD FLOOR POWER LAYOUT


SCALE: 1:100
ROOF DECK POWER LAYOUT
SCALE: 1:100

PROFESSIONAL ELECTRICAL ENGINEER: CADD BY: REVISIONS : PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO:

THREE (3) STOREY RESIDENTIAL &


COMMERCIAL BUILDING WITH BASEMENT

PROJECT LOCATION:
DANIELLE SHAE DUCUSIN GALACGAC
AS SHOWN
E-5
PRC REG. NO. :
VALIDITY :
PTR NO. :
PLACED ISSUED : 15 23
23O V, SINGLE PHASE
60 HZ POWER SUPPLY

110 AT

1
Lighting Load Lighting Load
2
ELECTRICAL SYMBOLS:
20AT 20AT
PB
Lighting Load Lighting Load
3 20AT 4 PANEL BOARD
20AT
Lighting Load Lighting Load
WEATHERPROOF CONVINIENCE
5 30AT 6 OUTLET WP
30AT
Lighting Load C.O. AIR CONDITIONING UNIT
7 30AT 8 ACU
30AT
C.O. C.O. DUPLEX CONVINIENCE OUTLET
9 30AT 10
30AT SERVICE ENTRANCE
C.O. C.O.
11 12 (INDICATE THE NUMBER OF CONDUCTOR,
30AT 30AT
SIZE, TYPE AND VOLTAGE)
Water Heater Water Heater
13 30AT 14 SERVICE KILOWATT-HOUR METER M
30AT
ACU 1.5HP ACU 1.5HP
15 30AT 30AT 16 PIN LIGHT
ACU 1.5HP ACU 2.0HP CIRCUIT BREAKER
17 30AT 30AT 18 (INDICATE TYPE AND Kv SETTING)
ACU 2.0HP Refrigerator
19 20 GROUND
30AT 30AT

21
RANGE SPARE
20
SINGLE POLE SWITCH S
30AT 30AT DUPLEX SWITCH, 2 SINGLE POLE SWITCHES
ON ONE GANG SWITCH PLATE
S 2

CENTER LIGHT
FLORESCENT LAMP

GROUND WIRE

RISER DIAGRAM
SCALE: NTS

PROFESSIONAL ELECTRICAL ENGINEER: CADD BY: REVISIONS : PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO:

THREE (3) STOREY RESIDENTIAL &


COMMERCIAL BUILDING WITH BASEMENT

PROJECT LOCATION:
DANIELLE SHAE DUCUSIN GALACGAC
AS SHOWN
E-6
PRC REG. NO. :
VALIDITY :
PTR NO. :
PLACED ISSUED : 16 23
SCHEDULE OF LOAD
NO. NO.
BREAKER CONDUCT
DESCRIPTION OF VOLTS WIRE SIZE
WATTS AMPERES SIZE WIRE
OUTLET
1 Lighting Load 5 500 230 2.17 15A ELECTRICAL NOTES:
800 1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN
2 Lighting Load 8 230 3.47 15A
ACCORDANCE WITH THESE PLANS & SPECS, AND THE APPLICABLE
3 Lighting Load 29 2900 230 12.61 15A PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE, IT'S RULES & REGULATIONS, OF THE LOCAL
4 Lighting Load 22 2200 230 9.56 15A ENFORCING AUTHORITY & THE REQUIREMENTS OF THE LOCAL
POWER COMPANY. THE ELECTRICAL WORK SHALL BE UNDER THE
5 Lighting Load 16 1600 230 6.96 15A IMMEDIATE SUPERVISION OF A DULY LICENSED PROFESSIONAL
6 Lighting Load 21 2100 230 9.13 15A ELECTRICAL ENGINEER.

7 Lighting Load 4 400 230 1.74 15A 2. ALL WIRES SHALL BE COPPER & THERMOPLASTIC INSULATED TYPE
800 3.43 20A " THHN " UNLESS OTHERWISE INDICATED. USE PHELPS DODGE OR
8 Convenience Outlet 4 230 COLUMBIA BRAND.
9 Convenience Outlet 6 1200 230 6.22 20A
3. THE CONTRACTOR SHALL VERIFY & ORIENT THE ACTUAL LOCATION
10 Convenience Outlet 10 2000 230 8.70 20A OF SERVICE ENTRANCE FOR CONNECTION TO THE POWER SUPPLY.
11 Convenience Outlet 10 2000 230 8.70 20A
12 Convenience Outlet 2 400 230 1.74 20A 4. ALL FEEDERS & BRANCH CIRCUIT HOMERUNS SHALL BE INSTALLED
AS INDICATED ON THE PLANS. BRANCH CIRCUIT HOMERUN WIRES
13 Water Heater 1 3000 230 4.35 30A SHALL BE INSTALLED IN INDIVIDUAL HOMERUN CONDUITS.
14 Water Heater 1 3000 230 4.35 30A 5. ANY DISCREPANCY IN LOCATION & RATINGS OF EQUIPMENT AND/OR
APPARATUS TO BE INSTALLED SHALL BE VERIFIED WITH THE OWNER
15 ACU 1.5HP 1 ------- 230 12.00 30A ------- OR HIS AUTHORIZED REPRESENTATIVE, & CHANGES SHALL BE
16 ACU 1.5HP 1 ------- 230 12.00 30A ------- MADE ACCORDINGLY.

17 ACU 1.5HP 1 ------- 230 12.00 30A ------- 6. ALL MATERIALS & EQUIPMENT TO BE USED & INSTALLED SHALL BE
------- ------- BRAND NEW, OF THE APPROVED TYPE FOR THE LOCATION AND
18 ACU 2.0HP 1 230 12.00 30A PURPOSE INTENDED.
19 ACU 2.0HP 1 ------- 230 12.00 30A ------- 7. ALL POWER & CONVENIENCE OUTLETS SHALL BE GROUNDING TYPE.
20 Refrigerator 1 2500 230 4.35 30A
8. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS:
21 Range 1 3000 230
a. LIGHT SWITCHES - 1.40 M. ABOVE FINISH FLOOR LINE
21 SPARE ------- ------- ------- 30A ------- b. CONVENIENCE OUTLETS - 0.30 M. ABOVE FINISH FLOOR LINE
c. TELEPHONE OUTLETS - 0.30 M. ABOVE FINISH FLOOR LINE
d. PANELBOARDS & CABINETS - 1.40 M. ABOVE FINISH FLOOR LINE
TOTAL 28,400 220 146.53 110 AT 25mm dia. PVC e. CABLE TV OUTLET- 0.30 M. ABOVE FINISH FLOOR LINE

PROFESSIONAL ELECTRICAL ENGINEER: CADD BY: REVISIONS : PROJECT TITLE: PROJECT OWNER: SHEET CONTENT: SHEET NO:

THREE (3) STOREY RESIDENTIAL &


COMMERCIAL BUILDING WITH BASEMENT

PROJECT LOCATION:
DANIELLE SHAE DUCUSIN GALACGAC
AS SHOWN
E-7
PRC REG. NO. :
VALIDITY :
PTR NO. :
PLACED ISSUED : 17 23
TIN
: