Installation and Operation Manual
ECDIS EC1000
Supplement for Digitizer
            By Furuno Navintra Oy
APPLICATION FOR MANUAL REVISIONS
Upon receipt of this manual, please fill in the necessary data. It is important that the addressee be the end
user so that the operating personnel will receive all revisions to the manual.
EQUIPMENT NAME ..........................................................….........................……...........…….
SERIAL No ...................................................MODEL .....…….......................……........…..…...
MANUAL TITLE ............................................................…............................…….............…….
............................................ MANUAL PART NUMBER .…..........................…….........…...….
ISSUE INDEX .................................... REVISION INDEX .............................…….........…....…
PURCHASING AGENCY ............…................................................................…….........…...…
NAME OF USER .....................….....................................................................……........…...…
ADDRESS OF USER ............…...............................................................................….………..
                               ................................................................................................….……
                               ................................................................................................….……
                               ...............................................................................................………..
                               ATTN:......................................................................…..............….….
CHANGE RECORD
 RCS CODE/REV.                    DATE                 PURPOSE OF THE CHANGE                                      CHANGE
 INDEX                                                                                                            REQUESTED BY
 1.0                              16.06.2003           Initial release of Installation and
                                                       Operators Manual for ECDIS software
                                                       version 03.01, 03.03 and 04.00
2 · Contents
Contents
Operation with ECDIS                                                                                                                                                                 1
Introduction...........................................................................................................................................................................1
Basic operations ....................................................................................................................................................................2
How to activate Digitizer ......................................................................................................................................................2
How to make a route with digitizer.......................................................................................................................................2
How to make an User Chart with digitizer............................................................................................................................2
How to make a Pilot Data with digitizer ...............................................................................................................................2
How to make a Reference Target with digitizer....................................................................................................................2
Calibration of Digitizer .........................................................................................................................................................3
Introduction...........................................................................................................................................................................3
First time calibration of a new paper chart............................................................................................................................4
Calibration of already used paper chart.................................................................................................................................5
Installation                                                                                                                                                                         7
Introduction...........................................................................................................................................................................7
Configuration of Digitizer.....................................................................................................................................................8
Overview of the menu strip on Digitizer...............................................................................................................................8
Parameters Setup...................................................................................................................................................................9
Installation and Operation Manual                                                                                                                                Contents · 3
               This page is intentionally left blank
4 · Contents                                           Installation and Operation Manual
Operation with ECDIS
Introduction
Route, User Chart, Pilot Data and Reference Target position information can be defined in several ways:
    ·    Select button of ECDIS Control Panel and Cursor on Electronic Chart Area as source of Latitude and
         Longitude values
    ·    Manual entry as source of Latitude and Longitude values
    ·    Using Digitizer as source of Latitude and Longitude values
Possible objects for which position (Lat/Lon) can be transferred:
    ·    Waypoint of Route
    ·    Point, Line, Area, Symbol and Tidal of User Chart
    ·    Location of Pilot Data
    ·    Location of Reference Target
There are several buttons on Pointing device of Digitizer, but only button 0 is used to enter position. Only case when
any other buttons than 0 are used is when calibration of Digitizer is done (Buttons 1 and 2 of Pointing device of
Digitizer). Below is drawing of Pointing device of Digitizer.
 Button used                 0    1     2      3
 in normal operation
                            4     5     6      7
 Buttons used               8     9     A      B
 in calibration
                            C     D     E      F
                                            CalComp
Installation and Operation Manual                                                          Operation with ECDIS · 1
Basic operations
How to activate Digitizer
When you want to activate Digitizer to be used together with ECDIS you have to proceed as follows:
                                        1.   Press INITIAL SETTING on Control Panel of ECDIS.
                                        2.   Select Digitizer from the menu. A following window appears to upper
                                             right hand corner of ECDIS display:
                                        3.   Current Coordinates field displays position of Pointing Device on
                                             Digitizer. Use this field to find out if there is need for Calibration.
                                             Status (In proximity or Out of Proximity) indicates whether Pointing
                                             device is inside area where Digitizer can recognize it.
                                        4.   When this window is open, you can use digitizer as a source of
                                             Latitude and Longitude values.
                                        5.   Press Cancel button when you stop use of Digitizer.
How to make a route with digitizer
Route planning can be done with Digitizer. You have to have Digitizer Interface window open, which enables also
coordinates entry by Digitizer. Button 0 of Pointing device is used to enter Waypoint position from paper chart. See
also chapter “Route Planning” in Operators Manual of ECDIS.
How to make an User Chart with digitizer
User Chart planning can be done with Digitizer. You have to have Digitizer Interface window open, which enables also
coordinates entry by Digitizer. Button 0 of Pointing device is used to enter Point, Symbol, Line, Area or Tidal position
from paper chart. See also chapter “User Chart” in Operators Manual of ECDIS.
How to make a Pilot Data with digitizer
Route planning can be done with Digitizer. You have to have Digitizer Interface window open, which enables also
coordinates entry by Digitizer. Button 0 of Pointing device is used to enter Pilot Data position from paper chart. See
also chapter “Pilot Data” in Operators Manual of ECDIS.
How to make a Reference Target with digitizer
Route planning can be done with Digitizer. You have to have Digitizer Interface window open, which enables also
coordinates entry by Digitizer. Button 0 of Pointing device is used to enter Reference Target position from paper chart.
See also chapter “Reference Target” in Operators Manual of ECDIS.
2 · Operation with ECDIS                                                              Installation and Operation Manual
Calibration of Digitizer
Introduction
Calibration must be done to define orientation and scale of paper chart on Digitizer. Calibration is required when you
start digitizing using new paper chart or you have moved already calibrated paper chart. To check if calibration is
required, proceed as follows:
                                         1.   Press INITIAL SETTING on Control Panel of ECDIS.
                                         2.   Select Digitizer from the menu. A following window appears to upper
                                              right hand corner of ECDIS display:
                                         3.   Current Coordinates field displays position of Pointing Device on
                                              Digitizer. Use this field to find out if there is need for Calibration.
                                         4.   Press Calibrate button to start calibration.
Picture 1. Good position for selected calibration points.
Installation and Operation Manual                                                                Operation with ECDIS · 3
 Picture 2                                   Picture 3                                    Picture 4
Pictures 2-4 demonstrate what you have to fill in Digitizer Calibrate window. See chapters “First time calibration of a
new paper chart” and “Calibration of already used paper chart” to find detailed procedure of calibration.
First time calibration of a new paper chart
When you start digitizing with a new paper chart, you have to proceed as follows:
    1.   After you have pressed Calibrate button in Digitizer Interface window, a Digitizer Calibrate window appears
         see Picture 2.
    2.   Press Name button to give name for calibrated paper chart, see Picture 3
    3.   You have to specify suitable corner co-ordinates and mean latitude, see Picture 1 and Picture 3. You must also
         specify Datum (if known) or WGS84 shift (if known). If both of them are unknown, you must find out
         yourselves the required WGS84 shift. Typically either Datum or WGS84 shift are printed in a legend of the
         paper chart.
    4.   Enter value of Mean Latitude, see Picture 3. Typically it is printed in a legend of the paper chart.
    5.   Enter value of Upper right corner and Lower left corner, see Picture 3.
    6.   Press Save button to store entered value for later use.
    7.   Move Pointing device of Digitizer to defined Upper right corner and press button 2 on Pointing device.
         Then Move Pointing device of Digitizer to defined Lower left corner and press button 0 on Pointing device.
         Finally move Pointing device of Digitizer to Lower right corner and press button 1 on Pointing device
    8.   Check from Calculated values that Lat scale and Lon scale are about equal to scale of paper chart. Small
         differences are acceptable, because the size and shape of paper chart changes depending on surrounding
         circumstances, like humidity etc.
4 · Operation with ECDIS                                                              Installation and Operation Manual
    9.   Check from Current coordinates field that Lat and Lon values on are close enough values pointed on paper
         chart. If you have big discrepancy, continue in step 7.
    10. Digitizer is now calibrated, close Digitizer calibration window by pressing OK button.
Calibration of already used paper chart
When you start digitizing with already used paper chart, you have to proceed as follows:
    1.   After you have pressed Calibrate button in Digitizer Interface window, a Digitizer Calibrate window appears
         see Example 1.
    2.   Select desired chart from Paper chart id list box for recalibration.
    3.   Check that values of Datum or WGS84 shift, Mean Latitude, Upper right corner and Lower left corner
         are correctly entered.
    4.   Move Pointing device of Digitizer to defined Upper right corner and press button 2 on Pointing device.
         Then Move Pointing device of Digitizer to defined Lower left corner and press button 0 on Pointing device.
         Finally move Pointing device of Digitizer to Lower right corner and press button 1 on Pointing device
    5.   Check from Calculated values that Lat scale and Lon scale are about equal to scale of paper chart. Small
         differences are acceptable, because the size and shape of paper chart changes depending on surrounding
         circumstances, like humidity etc.
    6.   Check from Current coordinates field that Lat and Lon values on are close enough values pointed on paper
         chart. If you have big discrepancy, continue in step 4.
    7.   Digitizer is now calibrated, close Digitizer calibration window by pressing OK button.
Installation and Operation Manual                                                           Operation with ECDIS · 5
                           This page is intentionally left blank
6 · Operation with ECDIS                                           Installation and Operation Manual
Installation
Introduction
Calcomp DrawingBoard III can be connected to COM 2: port of ECDIS, see figure below. Through the serial line
Latitude and longitude value of pointing device is transferred to ECDIS.
                                                 COM2: port
                                                 for connection
Installation and Operation Manual                                                            Installation · 7
Configuration of Digitizer
Overview of the menu strip on Digitizer
There are several keys on Digitizer which is used to configure Digitizer. See figure below to find location of keys on
Digitizer.
        Digitizer
        POWER LED
        CONFIGURATION LED
            CONFIG/EXIT KEY
                                                                       SAVE       RESTORE
                                  CONFIGURATION KEYS (1-18)          KEYS (1-3)   KEYS (1-3)
              BANK KEYS (A-C)
The menu strip is composed of:
    ·    Config/Exit key
         The Config/Exit key turns configuration on and off.
    ·    3 Bank keys
         There are three Bank keys: A, B and C. Each bank has a different set of tablet options that are available
         through Configuration key combinations.
    ·    18 Configuration keys
         The keys numbered 1-18 can be used as Configuration keys. When the tablet is in configuration mode, they
         function as Configuration keys. These keys allow you to set specific tablet options by turning different
         combinations of Configuration keys ON or OFF
    ·    3 Save and 3 Restore keys
         The Save and Restore keys work hand in hand. They are used to save (or recall) a setup to (or from) one of
         three save areas. There are three pre-programmed setups that come with tablet. You cannot use any of them
         directly with ECDIS. You can overwrite them with setup used with ECDIS.
8 · Installation                                                                               Installation and Operation Manual
Parameters Setup
To get Calcomp DrawingBoard III to communicate with ECDIS, you must first configure settings of Calcomp
DrawingBoard III. This is done by turning certain combination of Configuration keys on or off. The set options are
available table below.
           1    2    3    4     5    6    7    8     9    10     11     12     13    14     15     16     17     18
 A         1    1    0    0     0    1    1    1     1    1      0      1      1     1      1      1      0      1
 B         0    0    1    0     0    1    0    0     0    1      1      1      1     1      0      0      1      0
 C         0    0    1    1     0    0    0    0     0    0      0      0      0     0      0      0      0      0
To set up tablet to operate with ECDIS, proceed as follows:
     1.   Switch power on. Turn on configuration mode by pressing button 0 on pointing device over the Config/Exit
          key. The configuration light will turn on and remain on while the tablet is in configuration mode.
     2.   Click on the Bank you need to work (A, B or C). Move pointing device over Bank key and press button 0 on
          pointing device.
     3.   Set the Configuration keys ON or OFF by placing the pointing tool over each key. You can change it’s status
          by pressing button 0 on pointing device. Key is ON (on table marked as 1) if power light is on. Key is OFF
          (on table marked as 0) if power light is off. Make setups as shown table above.
     4.   Repeat steps 2 and 3 for the remaining banks.
     5.   After you have completed your setup, you can save it by pressing button 0 on pointing device over Save key.
     6.   Turn off configuration mode by pressing button 0 on pointing device over the Config/Exit key.              The
          configuration light will turn off.
Installation and Operation Manual                                                                       Installation · 9