CA NO.

CWE / BPL / B / OF 2024-25

NAME OF WORK: CONSTRUCTION OF LAB (7M X 10.6M) AT PM SHRI KENDRIYA VIDYALAYA BAIRAGARH UNDER GE BHOPAL

SCHEDULE 'A' PART - II (EXCAVATION AND EARTH WORKS)

Unit

Period of
completio
Sl Description of item of work No of Rate per Unit (Rs) Amount (Rs)

Drawings

Remarks
Ref to
No Units
required

1 2 3 4 5 6 7 8 9
1.00 Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil Sqm 50.00 73.10 3655.00
complete all as specified and directed.
2.00 M&L for Moorum filling in bottom, brought from outside MD land with any lead, including spreading, Cum 11.70 1240.10 14509.17
levelling, watering & well ramming, in layers not exc 15 cm each complete all as specified and directed.

3.00 M&L for hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in Cum 7.50 2070.80 15531.00
layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.

4.00 Excavation in trenches not exceeding 1.5 Mtr in depth and not exceeding 1.5 mtr wide for laying of cable Cum 52.00 675.00 35100.00
complete all as specified and directed.
5.00 Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or Cum 8.00 529.35 4234.80
not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier
holes, etc and getting out in in any type of soil complete all as specified and directed. .

6.00 Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in Cum 33.00 185.00 6105.00
layers not exceeding 25cm each complete all as specified and directed.

7.00 M&L for returning , filling in including spreading, leveling and well ramming in layers not exc 25 cm thick Cum 6.00 139.10 834.60
complete all as specified and directed.
8.00 M&L for Removal of excavated material not exceeding 50 mtr and deposited where directed at a level Cum 19.00 320.40 6087.60
not exceeding 1.5 mtr above the starting point complete all as specified and directed.
9.00 Removing excavated material exc. 500 m but n exc. 1.5 km and depositing where directed at a level n Cum 2.00 364.80 729.60
exc 1.5 mtr above starting point.
10.00 Removing excavated materials (soil) to a distance exc. 1.50 km and deposting where directed, at a Cum 7.50 623.40 4675.50
level n.exc. 1.5m above the starting point complete all as specified.

Total of Sch 'A' Part-II c/o to BOQ 91462.27


CA NO. CWE / BPL / B / OF 2024-25
SCHEDULE ‘A’ PART – III (INTERNAL ELECTRIFICATION WORKS)
Notes:-
(i) The complete wiring installation shall be carried out in accordance and conformity with IS:732:1989 "Code of practise for electrical wiring(latest version)"
(ii) All screws, fasteners, bolts, nuts & washers etc shall be of cadmium plated, the cost of which is deemed to be included in the unit rate.
(iii) The complete wiring installation shall be tested on completion as specified in particular specifications.

Drg No.

Remarks
completio
Period of
Srl No. Description of works Unit Nos of Rate per Unit (Rs) Amount (Rs)
Units
reqd

1 2 3 4 5 6 7 8 9
1.00 S&F Modular switch, one way, 6 Amp 230, 1 module complete all as specified and directed. Each 23.00 260.50 5991.50
2.00 Supply and fixing modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete Each 1.00 392.20 392.20
all as specified and directed.
3.00 S&F ceiling rose, 6A, 240V, surface type, PVC/polycarbonate isolated body complete all as specified Each 18.00 65.70 1182.60
and as directed.
4.00 S&F of modular socket 6Amp, 2/3 pin combined 2 module complete all as specified and directed. Each 3.00 340.54 1021.62
5.00 S & F modular metal flush box of 6 module complete all as specified and directed. Each 4.00 284.10 1136.40
6.00 S & F modular metal flush box of 4 module complete all as specified and directed. Each 1.00 213.40 213.40
7.00 S & F modular metal flush box of 3 module complete all as specified and directed. Each 1.00 179.80 179.80
8.00 S & F modular white cover plate of 6 module complete all as specified and directed. Each 6.00 309.60 1857.60
9.00 S & F modular white cover plate of 4 module complete all as specified and directed. Each 1.00 247.10 247.10
10.00 S & F modular white cover plate of 3 module complete all as specified and directed. Each 1.00 217.70 217.70
11.00 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and Each 2.00 3548.59 7097.18
frame and louvers all as specified and directed.
12.00 Supply and fixing 5 star rated BLDC (Brush less direct current motor) ceiling fan 230 volts, single phase Each 6.00 2649.47 15896.82
of 1200mm sweep double ball bearing type with minimum air delivery 210 CMM & service value shall not
be less than 6.0 B.E.E including blade, down rod and canopy cover etc and including connecting with 3
core flexible copper conductor cable of size 0.50 sqmm and including writing of MES No with black
synthetic enamel paint complete all as specified and as directed.
13.00 S&F sheet metal enclosure for SPN DB ( single pole and neutral) single door type surface mounted Each 1 1578.70 1578.70
concealed in wall 8 ways, 240 Volts, IP 43,ISI marked 200 amps bus bar dust and vermin proof
suitable for incorporation MCBs and isolators etc complete all as specified and directed.
NOTE:- MCB shall be measured and paid separately.
14.00 S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 6 to 32 amps Each 6 294.00 1764.00
including connection with suitable size aluminium / copper lugs complete all as specified and directed.

15.00 S & F in repairs MCB SPN suitable for 240 volts, AC supply 32 Amps, C Curve, with over load and Each 1 851.20 851.20
short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
CA NO. CWE / BPL / B / OF 2024-25
SCHEDULE ‘A’ PART – IV (INTERNAL WATER SUPPLY WORKS)

Drg No.

Remarks
Period of
completi
Srl No. Description of works Unit Nos of Rate per Unit (Rs) Amount (Rs)
Units
reqd

1 2 3 4 5 6 7 8 9
1.00 S & F of 25mm bore dia tubes medium grade galvanised, with all necessary fitting and fixed complete RM 20.00 196.00 3920.00
to walls and ceilings or laid in floors complete all as specified.

2.00 S & F of 20mm bor dia tubes medium grade galvanised, with all necessary fitting and fixed complete to RM 15.00 169.00 2535.00
walls and ceilings or laid in floors complete all as specified.

3.00 S & F of 15mm bor dia tubes medium grade galvanised, with all necessary fitting and fixed complete to RM 10.00 143.00 1430.00
walls and ceilings or laid in floors complete all as specified.

4.00 S&F,15 mm bore bib tap, cast copper alloy fancy type, screwed down screwed for iron pipe or for brass Each 4.00 607.57 2430.28
ferrule complete all as specified and as directed.

5.00 S&F for ISI Marked 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and Each 1.00 427.06 427.06
high density plastic ball screwes for iron pipe complete all as specified and directed.

6.00 S & F of 20mm Gate Valves (gun metal, with iron wheel) screwed both ends for iron pipes and fixed Each 1.00 540.11 540.11
complete all as specified and as directed.

Total of Sch 'A' Part-IV c/o to BOQ 11282.45


CA NO. CWE / BPL / B / OF 2024-25 SCHEDULE ‘A’ PART – V (EXTERNAL ELECTRIFICATION WORKS)

Unit

Period of
completi
Drawings
Sl Description of item of work No of Rate per Unit (Rs) Amount (Rs)

Remarks
Ref to
No Units
required

1 2 3 4 5 6 7 8 9
1.00 Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy RM 120.00 143.61 17233.20
duty cable with aluminium conductor of size 10 sqmm, 2 core, 1100 volts grade, laid in trenches,
passing through pipes/ducts, etc including taking out old unserveciable cable, any type complete all as
specified and directed.

2.00 M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in Cum 8.00 1974.30 15794.40
trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and
directed. [Note:-
Compacted/punned thickness shall be measured & paid]

3.00 Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x Each 400.00 44.20 17680.00
150mm x 40mm complete all as specified and directed.

4.00 S&F 40mm GI tubing light grade( as per IS -1239), with all fittings as required for passing through RM 30.00 399.50 11985.00
cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl
nut,bolt and washer including taking down old rusted pipe complete all as specified and directed.

Total of Sch 'A' Part-V c/o to BOQ 62692.60


CA NO. CWE / BPL / B / OF 2024-25
SCHEDULE ‘A’ PART – VI (EXTERNAL WATER SUPPLY WORKS)

Drg No.

Remarks
Period of
completi
Srl No. Description of works Unit Nos of Rate per Unit (Rs) Amount (Rs)
Units
reqd

1 2 3 4 5 6 7 8 9
1.00 S&F in position Rotational moulded polyethylene water storage tanks, 3 layers, (cylindrical vertical with Each 1.00 4219.60 4219.60
closed top) of capacity 500 litres hoisted and fixed in position all as specified and directed.

2.00 Supply and laying GI tubing medium grade(as per IS 1239), inclusive of all fittings of size 25 mm RM 80.00 184.60 14768.00
including provision of tapping to main water pipeline , including laying down in trenches complete all as
specified and directed .

3.00 Supply and laying GI tubing medium grade( as per IS 1239), inclusive of all fittings of size 20 mm RM 20.00 158.60 3172.00
including provision of tapping to main water pipeline , including laying down in trenches complete all as
specified and directed .

4.00 Supply and fixing. Gun metal, globe or gate valves (ISI Marked) with iron wheel head, screwed both end 1174.48
for iron pipe and fixed of size 25mm bore including all fittings complete all as specified and directed.
Each 2.00 587.24

5.00 Supply and fixing. Gun metal, globe or gate valves (ISI Marked) with iron wheel head, screwed both end 540.11
for iron pipe and fixed of size 20mm bore including all fittings complete all as specified and directed.
Each 1.00 540.11

Total of Sch 'A' Part-VI c/o to BOQ 23874.19


CA NO. CWE / BPL / B / OF 2024-25 SCHEDULE ‘A’ PART-VII (PATH WORKS)

Unit

Period
of
Sl Description of item of work No of Rate per Unit (Rs) Amount (Rs)

Drawing

Remark
Ref to
No Units

s
required

1 2 3 4 5 6 7 8 9
1.00 M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) 100 mm thick as in sub base Sqm 50.00 533.00 26650.00
concrete complete all as specified and directed.

2.00 M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS Sqm 50.00 955.00 47750.00
15658 -2006 of 80 mm thickness, M-40 grade with grey cement and pigment for path etc complete all as
specified and directed.

3.00 M&L for sand filling under floors or in foundations including watering and consolidation for sand Cum 2.50 1974.30 4935.75
cushioning for paver block complete all as specified and directed.

4.00 M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span , Cum 4.00 9259.40 37037.60
cills, steps, seismic and other similar bands, coping, kneelers, apex stones, bed plates, kerbs and the
like including weathering, slightly rounded or chemfered angle and throating, complete all as specified
and directed.

Total of Sch 'A' Part-VII c/o to BOQ 116373.35


CA NO. CWE / BPL / B / OF 2024-25 SCHEDULE ‘A’ PART – VIII (SEWAGE DISPOSAL WORKS)

Unit

Period of
completi
Drawings
Sl Description of item of work No of Rate per Unit (Rs) Amount (Rs)

Remarks
Ref to
No Units
required

1 2 3 4 5 6 7 8 9
1.00 M&L for concrete bed to drain pipes 150 mm dia incl packing under, and haunching against the sides of RM 28.00 455.02 12740.56
pipes after they are laid and tested in 1:4:8 type D2 (using 40 mm graded stone aggregate) complete
all as specified and directed.
2.00 M&L for 150 mm dia RCC NP2 drain pipes laid in trenches and jointed as specified complete all as RM 30.00 364.00 10920.00
specified and directed.
3.00 M&L for fly ash brick work with modular bricks straight or curved on plan exc 6 m mean radius, built in Cum 0.85 5731.64 4871.89
CM 1:6 complete all as specified and directed.
4.00 M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span , Cum 0.10 9259.40 925.94
cills, steps, seismic and other similar bands, coping, kneelers, apex stones, bed plates, kerbs and the
like including weathering, slightly rounded or chemfered angle and throating, complete all as specified
and directed.
5.00 M&L for precast cement concrete type B1 (20 mm graded aggregates) as in cover slab for manholes etc Cum 0.20 11053.80 2210.76
set in CM 1:4 complete all as specified and directed.

6.00 M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation , filling, sub Cum 0.25 5483.10 1370.78
base and mass concrete complete all as specified and directed.
7.00 M&L Mild steel TMT bars 6 to 8 mm dia bars, cut to length, bent to shape required, including cranking, Kg 55.00 82.60 4543.00
bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire
(annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.

8.00 M&L 15 mm thick rendering in CM 1:4 on brick/concrete surfaces of walls including finishing the Sqm 5.50 304.24 1673.32
surfaces even and smooth (without using extra cement) incl mixing WPC complete all as specified and
directed.
Note: WPC will be measured and paid separately

9.00 Cutting into existing manholes/septic tanks for connecting new drains, making good to pipes and Each 1.00 1120.00 1120.00
rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section ) in cement pipe
concrete 1:2:4 type B1 smooth finished, and reforming benching as required dia 150 mm complete all as
specified and directed.

10.00 Supply only liquid water proofing compound complete all as specified and directed. Ltr 0.50 261.50 130.75