0 1 2 3 4 5 6 7 8 9

ALL
A

Schneider Electric

The technical information contained in this document is the exclusive property os Schneider-electric abd can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off
B

Company / customer
Project description RM AirSet
Job number
C

Commission

Manufacturer (company) Schneider Electric

www.schneider-electric.com
D

Project name RMU-12-3F-IBI


Make
E

Created on 4/4/2024 by ALL Checked by Approved by

Modified on by SRV991759 Number of pages 6


F

1-2-GC1
Date 4/4/2024 Schneider Electric Description CS =
Ed. SRV991759 +
Appr RM AirSet Page 0-1-CS1
Modification Date Name Original Replacement of Replaced by Page 6
0 1 2 3 4 5 6 7 8 9

Electrical characteristics :
A

Rated voltage (Ur / kV) - - - - - - - - - - - - - - - - - - - - - - - - - - 12 kV


Rated service voltage (Us / kV) - - - - - - - - - - - - - - - - - - - - - - 10 kV

The technical information contained in this document is the exclusive property os Schneider-electric abd can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off
Rated insulation level
Power frequency withstand voltage 50Hz - 1mn (Ud / rms kV) - - 28 kV
Lightning impulse withstand voltage 1,2/50 μs (Up / kV peak) - - 75 kV
Rated normal current and maximum short time withstand current
B

Short time withstand current ( Ik / kA - tk / s) - - - - - - - - - - - - - 20 kA / 1s


Short circuit making current at 50Hz ( Ip / peak value kA) - - - - - 50 kA
Busbar rated current - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - 630 A
Rated frequency - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 50 Hz
Internal arc classification
Internal arc current ( Ik / kA - tk / s) - - - - - - - - - - - - - - - - - - - 20 kA / 1s
Internal arc classification (IAC) - - - - - - - - - - - - - - - - - - - - - - - AFLR
C

Earth circuit short time withstand duration - - - - - - - - - - - - - - - 1s

Switchboard information:
Applicable standard - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IEC
D

Product - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - RM AirSeT
Cubicle information - - - - - - - - - - - - - - - - - - - - - - - - - - - - - (01) I B I DE (Double Extensible)
E
F

0-1-CS1 1-3-SLD1
Date 4/4/2024 Schneider Electric Description GC =
Ed. SRV991759 +
Appr RM AirSet Page 1-2-GC1
Modification Date Name Original Replacement of Replaced by Page 6
0 1 2 3 4 5 6 7 8 9

10 kV ; 3~ 50 Hz; 630 A; 20 kA
A

1s

The technical information contained in this document is the exclusive property os Schneider-electric abd can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off
630A 630A 630A
B
C

VPIS V2 VPIS V2 VPIS V2


D

1 Cable/Phase x Single Core 1 Cable/Phase x Single Core 1 Cable/Phase x Single Core


Note:
M=Motor
F2=Closing coil
F11=Opening coil
F4=Undervoltage opening coil

Function number 1 2 3
E

Function I 630A B 630A I 630A


PLATE LABEL

Cubicle DE-I B I
F

1-2-GC1 1-4-FV1
Date 4/4/2024 Schneider Electric Description SLD =
Ed. SRV991759 +
Appr RM AirSet Page 1-3-SLD1
Modification Date Name Original Replacement of Replaced by Page 6
F E D C B A

Modification
0

1-3-SLD1

Date
Name
1625

Cubicle
Cubicle No.
1

Ed.
20

Date

Appr
Original
RM AirSeT
Air

4/4/2024
SRV991759
1
1120

DE-I B I
RM AirSeT
Air
2

°C

-25

20

40

60

RM AirSeT

RM AirSet
Air

20

Replacement of
3

Replaced by
4

Schneider Electric
5

Description FV
6
7
8

+
=
9

Page
Page
1-5-FI1

The technical information contained in this document is the exclusive property os Schneider-electric abd can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off
6
1-4-FV1
F E D C B A

Modification
1-4-FV1
0

Date
Name
Cubicle
Cubicle No.
1

Ed.
Date

Appr
Original
4/4/2024
SRV991759
1

1120
DE-I B I
2

RM AirSet
Replacement of
3

Replaced by
4

Schneider Electric
5

Description FI
6
7
8

+
=
9

Page
Page
1-7-CCV1

The technical information contained in this document is the exclusive property os Schneider-electric abd can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off
6
1-5-FI1
0 1 2 3 4 5 6 7 8 9

TOP VIEW EXTENSION EXAMPLES


A

LE Left extension RE Right extension


LE : Left extensible RE : Right extensible

The technical information contained in this document is the exclusive property os Schneider-electric abd can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off
SIDE VIEW

780
B

1120
20 20

Front view 1120 : NE


1120 + 20 : LE / RE
1120 + 40 : DE (Double Extensible)
C

FI EXTENSION EXAMPLES

FLOOR IMPACT LE Left extension RE Right extension


AND GROUND FIXING

1078 378 42 1078 42 378


21 Ø13 x 6
(Foundation Holes)
D

407
780

243

243 407
56 74
56

420 1120 420


E

3 FUNCTION
F

1-5-FI1
Date 4/4/2024 Schneider Electric Description CCV =
Ed. SRV991759 +
Appr RM AirSet Page 1-7-CCV1
Modification Date Name Original Replacement of Replaced by Page 6