Manual Sonometro 2700
Manual Sonometro 2700
TABLE OF CONTENTS
MODEL 1700 PRECISION IMPULSE SOUND LEVEL METER
AND MODEL 2700 IMPULSE SOUND LEVEL METER
WITH THE OB-50, OB-100 AND OB-300
and 2700
B. Meter Controls . . . . . . . . . . . . . . . . . . . . . . . . 3
HOLD Button . . . . . . . . . . . . . . . . . . . . . . . . . 3
RESET Button . . . . . . . . . . . . . . . . . . . . . . . . 3
BATTERY Button . . . . . . . . . . . . . . . . . . . . . . . 3
Sound Level Meters RESPONSE Switch .
WEIGHTING Switch
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
4
MODE Switch . . . . . . . . . . . . . . . . . . . . . . . . . 4
dB RANGE Switch . . . . . . . . . . . . . . . . . . . . . . . 4
and POWER Switch . .
C. Overload Detection
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
4
D. Output Jacks . . . . . . . . . . . . . . . . . . . . . . . . . 4
DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Models OB-50 AC . . . . . . .
E. Internal Switches .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
5
and OB-100 Mic. Polarization
Display Time . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
5
Octave Band Filter
III. CHECKING THE METER INTEGRITY . . . . . . . . . . . . . . . . . . 6
and A. Battery Check . . . . . . . . . . . . . . . . . . . . . . . . .
B. Calibration . . . . . . . . . . . . . . . . . . . . . . . . . .
6
6
IV. GENERAL OPERATING CONSIDERATIONS . . . . . . . . . . . . . . . . 7
Model OB-300 A. Meter / Microphone Placement .
B. Background Noise . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
7
7
1/1 - 1/3 Octave Band Filter C. Wind Screen Effects . . . . . . . . . . . . . . . . . . . . . . 8
D. Chart Recording . . . . . . . . . . . . . . . . . . . . . . . . 8
V. TECHNICAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . 10
A. Principles of Operation . . . . . . . . . . . . . . . . . . . . 10
B. Microphone (model 1700) . . . . . . . . . . . . . . . . . . . . 11
C. Preamplifier Input Characteristics . . . . . . . . . . . . . . 12
D. Microphone (model 2700) . . . . . . . . . . . . . . . . . . . . 13
E. Microphone Preamp Extension Cables . . . . . . . . . . . . . . 14
F. Input Buffer Circuitry . . . . . . . . . . . . . . . . . . . . 15
G. Weighting Characteristics . . . . . . . . . . . . . . . . . . . 16
H. Internal Electrical Noise . . . . . . . . . . . . . . . . . . . 17
I. Tone Burst Response . . . . . . . . . . . . . . . . . . . . . . 18
Note: Due to the new ATEX Directive in Europe, all references in this document to "Ex"
or "EEx" for intrinsic safety approvals should be disregarded effective 7/1/03 within the VI. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . 21
member countries of the European Union (EU). At this time, this product is not approved
in accordance with the new ATEX Directive and is not sold for use in hazardous VII. ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
atmospheres or explosive zones by customers within the EU. Outside of the EU, all
references to intrinsic safety continue without change.
59-334 Rev D
4/97
I. INTRODUCTION TO THE MODELS 1700 AND 2700
The Quest Models 1700 and 2700 Impulse Sound Level Meters are general purpose
instruments designed for sound pressure level measurements with or without
the use of optional bandpass filters. The Model 1700 delivers Type 1
VIII. INTRODUCTION TO THE MODELS OB-50, OB-100 and OB-300. . . . . . . 24 accuracy, while the model 2700 provides Type 2 accuracy for general survey
work. Applications include laboratory, industrial, community and audiometric
IX. ABOUT THE FILTERS . . . . . . . . . . . . . . . . . . . . . . . . 24 measurement and analysis. Since the operation of the 1700 and 2700 are
A. Filter Controls . . . . . . . . . . . . . . . . . . . . . . . . 24 virtually identical, this manual will refer to the model 1700. Differences
B. Filter Connector . . . . . . . . . . . . . . . . . . . . . . . 25 between the two models will be detailed as appropriate.
X. OPERATING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . 25 The Model 1700 is a user-friendly hand held meter with an LCD display that
A. Operational Check . . . . . . . . . . . . . . . . . . . . . . . 26 provides a numerical and bar graph readout. It is housed in a tough
B. Taking a Measurement . . . . . . . . . . . . . . . . . . . . . 26 injection molded plastic case with internal shielding against external
AUTO Filter Operation . . . . . . . . . . . . . . . . . . . . 27 electromagnetic interference. The meter is operated with easy-to-use slide
switches and push buttons. Two output jacks are provided for connecting to
XI. TECHNICAL INFORMATION - OB-50 and OB-100 . . . . . . . . . . . . . 27 external peripherals such as chart recorders, oscilloscopes, tape recorders,
etc.
XII. SPECIFICATIONS - OB-50 and OB-100 . . . . . . . . . . . . . . . . 28
Plug in the Model OB-300 combination 1/3 - 1/1 Octave Filter Set and create
XIII. TECHNICAL INFORMATION - OB-300 . . . . . . . . . . . . . . . . . 28 a 1/3 or 1/1 octave band analyzer covering 33 bands from 12.5 Hz to 20 kHz.
The addition of the Model OB-100 Octave Filter
XIV. SPECIFICATIONS - OB-300 . . . . . . . . . . . . . . . . . . . . . 28 Set will create an octave band analyzer
covering 10 bands from 31.5 Hz to 16 kHz. The
XV. QUEST SERVICE AND WARRANTY POLICY . . . . . . . . . . . . . . . . . 30 Model OB-50 Octave Filter Set covers 9 bands
A. Service Policy . . . . . . . . . . . . . . . . . . . . . . . . 30 from 31.5 to 8kHz.
B. Warranty Policy . . . . . . . . . . . . . . . . . . . . . . . . 30
If sound measurements need to be made from a
distance, simply remove the microphone
preamplifier and insert an extension cable.
Cable distances of up to 100 feet can be
accommodated.
With the microphone and preamplifier removed,
the meter can accept other input devices such
as the Quest Model VI-90 Vibration Integrator.
The VA-508C Vibration Assembly, combined with
the Model 1700, provides a quick and precise
method of measuring and analyzing many types of
industrial vibration.
A. Assembling the Meter
1
to unscrew only the grid.
2. Never touch the diaphragm. 3. Electret (prepolarized) microphones should never be stored at high
temperatures, as long term degradation of the polarization charge
may occur. This results in a decrease in microphone sensitivity.
4. An electret microphone should be stored in its protective box when
not in use for long periods of time.
The LCD display contains both a numeric readout and a quasi-analog bar
indicator along with BAT (battery), HLD (hold), and OL (overload) indicators.
The rate at which the numeric display is updated depends upon the setting of
a switch which is located in the battery compartment. Either a one-second or
a one-quarter second display rate can be selected.
The bar indicator portion of the display will indicate the current SPL (Sound
Pressure Level), except when the BATTERY button is pressed. (See III. A.,
Battery Check). When using the bar indicator for SPL, the 0 to 60 range of
the bar indicator represents the range indicated by the setting of the Range
switch. If on the 80 to 140 range, for example, the bar indicator represents
80 to 140 dB.
The MODE switch selects either SPL or MAX for display. Sound levels are
shown to the nearest 0.1 dB.
2 3
B. Meter Controls WEIGHTING Switch
HOLD Button The WEIGHTING switch controls the frequency response of the meter.
Weightings A, B, C, or LINear (flat) may be selected. (See V. G.,
When the HOLD button is depressed, the current numeric value in the Weighting Characteristics for further information.)
display (either SPL or MAX) is frozen and the HLD annunciator appears in
the display. The last stored values of SPL and MAX can be viewed. MODE Switch
Simply use the MODE switch to select the value of interest. Pressing
HOLD will NOT stop the MAX value from updating if a higher value should The MODE switch selects either the instantaneous sound pressure level
occur. It simply saves the current value for viewing. (SPL) or the maximum sound pressure level (MAX).
HOLD is a toggle function. To exit the HOLD mode, simply press HOLD SPL - Sound Pressure Level will be displayed. (SPL is also
again. always shown in the display bar indicator.)
RESET Button MAX - The Maximum Sound Pressure Level obtained (starting from
the last time that the meter has been reset) is shown in
To reset the MAX value stored in the Model 1700, press the RESET button. the numeric display.
This will erase the MAX value prior to taking new readings. The
RESPONSE must be set to either SLOW, FAST, or IMP for the MAX reset to dB RANGE Switch
occur.
The displayed range of the Model 1700 is 60 dB and is switchable between
NOTE: Pressing RESET while the RESPONSE is set to PEAK only resets the following: 20-80 dB, 40-100 dB, 60-120 dB, or 80-140 dB.
PEAK. The MAX value is unaffected.
POWER Switch
BATTERY Button
This switch turns the power to the meter ON and OFF.
Pressing the BATTERY button will indicate relative battery strength in
the bar portion of the display. This button may be pressed at any time C. Overload Detection
without affecting the meter signal processing. (See III. A., Battery
Check) In the SPL mode, the overload indicator (OL) is displayed whenever the
incoming signal is of too high a level for the circuitry to accurately
RESPONSE Switch measure. It appears as OL in the upper right-hand corner of the display. If
the OL indicator is on, increase the setting of the dB RANGE switch until the
The RESPONSE switch controls the rate at which the meter responds to OL condition is removed causing OL to disappear.
changing input signals. Most sound measurements are done with the
response set to SLOW. The FAST response is generally used when D. Output Jacks
measuring short duration noises such as moving vehicles. PEAK is
generally used to capture very rapidly rising, extremely short duration All output jacks use a 3.5mm stereo plug. (See Figure 2)
signals (gun shots, etc.).
4 5
The functions of the output jacks are as follows:
III. CHECKING THE METER INTEGRITY
DC - The weighted and time averaged Sound Pressure Level (SPL) over the
selected 60 dB range is linearly represented by a 0 to 1 volt DC A. Battery Check
output. Zero volts is equal to the bottom of the range and 1 volt
is equal to full scale. This output is provided for connecting to At any time, the BATTERY push button can be pressed to get an indication of
a 0 to 1 volt full scale chart recorder or a data acquisition battery strength. The weaker of the two 9 volt batteries is shown on the bar
device that accepts DC voltages. (See IV. D., Chart Recording and indicator of the Model 1700's display. Good batteries will be indicated with
Figure 6, Chart Recording of SPL) the bar extending well beyond the indicating arrow (5 on the 0-60 scale). If
the bar falls below the indicating arrow, then BOTH ALKALINE batteries must
AC - This jack furnishes an amplified version of the AC signal from the be replaced. Because erroneous readings will occur if the battery check
microphone which is frequency weighted according to the WEIGHTING registers below the indicating arrow, it is good practice to perform a
switch setting. The full span of 60 dB is represented between 3.16 battery check before using the 1700. The stored MAX value and the AC and DC
millivolts and 3.16 volts RMS. outputs are NOT affected by performing a battery check.
There is an internal switch located in the battery compartment that is To check the calibration of the Model 1700, perform the following procedure
accessible to the user. (Refer to Figure 3) using a Quest Calibrator.
Mic. Polarization - The small ON/OFF switch on the right-hand side operates 1. Perform a battery check.
the 200 volt microphone polarization voltage which is
necessary for air-condenser microphones. (Model 1700 2. Turn the Calibrator ON and note the level specified on the label.
only) If the calibrator output is at a frequency other than 1kHz,
corrections to the calibration value may be necessary if
Display Time - The recessed dip switch controls the rate at which the calibrating with the meter set to A, B or C weighting.
display updates. The options are 1.0 second or 0.25
second. 3. If an adapter is needed to mate the microphone size to the
calibrator coupler, insert it fully into the calibrator.
4. Place the Calibrator (with adapter, if used) fully onto the
microphone.
5. Set the Model 1700 to LIN, SLOW or FAST, the SPL mode, and the 60-
120 range (if using a level of 94 dB).
6 7
IV. GENERAL OPERATING CONSIDERATIONS C. Wind Screen Effects
Before taking measurements with the Model 1700, there is a series of quick To prevent measurement errors due to noise caused by wind blowing across the
checks that should be performed. After switching the unit ON, the batteries microphone, the use of a windscreen is recommended. The wind screen will
should be checked (and replaced if needed). Although the Model 1700 will reduce wind effects and will also help protect the microphone under dusty,
maintain accurate calibration over a long period of time, the calibration oily, or humid conditions. Acoustic attenuation effects of the one-half inch
should be checked and the meter adjusted, if necessary, before each use. (WS-7) and the one inch (WS-3) windscreen are shown in Figure 5.
Set the RESPONSE, WEIGHTING, MODE, and dB RANGE switches as needed. Hold,
set, or tripod mount the meter in the desired location. If a MAX measurement D. Chart
is needed, reset the meter before taking the measurements. It is always a Recording
good idea to document all measurement conditions and meter settings for
possible future needs. The Model
1700 has a
A. Meter / Microphone Placement DC output
that is
Whenever possible, the meter should be tripod-mounted in an open area to linearly
minimize reflections from the body or other large reflective structures. related to
Avoid placement against a wall or in a corner. If reflections are of the 60 dB
concern, a microphone extension cable may be used for better microphone LCD analog
placement. b a r
movement
When using a random incidence or pressure microphone, point it approximately a s
70 degrees to the direction of the sound. If using a free-field microphone, follows:
point it directly at the noise source. Figure 5. Acoustic Effect of Windscreens
Refer to Figure 6, Chart Recording of SPL. Connect the Model 1700 to the
chart recorder input with proper polarity such that the pen is on the proper
side of the chart paper with respect to time and that the pen moves in the
proper direction with increasing dB level. Use a 1 kHz acoustic calibrator,
preferrably 94 dB, (dB level is specified on calibrator) to calibrate the
chart recorder as follows:
1. Turn the meter to ON. Set the meter RESPONSE to FAST, WEIGHTING to
A, MODE to SPL, and dB RANGE to 80-140.
8 9
2. Place the calibrator (with adapter, if used) fully onto the V. TECHNICAL INFORMATION
microphone - do not turn the calibrator on yet. The meter shall
read less than 80 dB which generates .00 volts DC out to the chart A. Principles of Operation
recorder. Adjust the zero control on the recorder so that the pen
represents a relative dB of 0. The Quest Model 1700 utilizes low noise, low power analog and digital
integrated circuitry to ensure long battery life, maximum stability, and
3. Turn the Calibrator ON to produce 94 dB (or the level specified on superior reliability over a wide range of environmental conditions. Figure
the label) at 1 kHz. Set the 1700 dB RANGE for the highest bar 7 is a block diagram of the Model 1700's internal circuit operations.
graph level without causing an overload. The recorder pen should
rise to the correct RELATIVE dB. (54 if the calibrator level is 94
dB and the dB RANGE is set to 40 to 100.) A small adjustment may
be needed. Use the zero adjust to do this.
4. Be sure to document all chart recorder settings and meter settings
when taking measurements.
Note that any range position can be set on the Model 1700 and the 60 dB
span of the meter range will always correspond to the full 60 dB range
on the chart recorder.
10 11
B. Microphone (model 1700) C .
Preamplifi
The Model 1700 is designed to accept either a half-inch or one-inch er Input
condenser microphone of either prepolarized (electret) or air-condenser type. Characteri
The prepolarized microphone does not require a polarization voltage. If the stics
air-condenser type is used, then the 200 volt microphone polarization voltage
must be turned on by a switch located in the battery compartment. (Sec II. The input
Figure 3., Internal Switches.) impedance
of the
CAUTION: Be careful not to turn on the 200 volt polarization switch if p r e a m p
a prepolarized (electret) microphone is attached. The affects
microphone may be damaged. both the
l o w
The microphone screws directly onto the preamp which, in turn, connects frequency
directly to the meter. The preamp converts the high output impedance of the response
microphone into a low output impedance. This allows the microphone to drive and the Figure 9. Typical Frequency Response - Model QE4170 Microphone
up to 100 feet of cable for remote operation. microphone
attenuatio
Typical microphones used on the 1700 include the following: n as shown in Figures 10 and 11. The approximate microphone capacitances for
the 1/2 inch and one inch microphones are 18pf and 60pf respectively. The
Model QE4146 1/2-inch free-field, prepolarized condenser preamp is removable by turning the black plastic collar below the preamp
(electret), 40 mv/Pa housing counter-clockwise when viewed from the top of the meter.
Model QE4170 1-inch pressure, 200 Volt polarization, 50 mv/Pa
Model QE4160 1/2-inch pressure, 200 Volt polarization, 50 mv/Pa
Model QE4150 1/2-inch free-field, 200 Volt polarization, 50 mv/Pa
Model QE4140 1/2-inch pressure, 200 Volt polarization, 16 mv/Pa
Typical microphone response curves for the Models QE4146 and QE4170 are shown
in Figures 8 and 9 respectively.
12 13
E. Microphone Preamp Extension Cables
D .
Microphone The microphone preamp converts the high output impedance of the microphone to
( m o d e l a low output impedance, thus allowing the insertion of an extension cable of
2700) up to 100 feet in length between the preamp and meter. Quest Technologies
offers the following lengths of remote cables:
T h e
model 2700
i s # 59-899 ICM-2 2 Ft. Remote Cable
designed # 59-733 ICM-10 10 Ft. Remote Cable
to accept # 59-734 ICM-50 50 Ft. Remote Cable.
a
prepolariz
e d The length of cable between the preamplifier and meter limits the high
(electret) frequency output capability of the preamplifer. Cable effects are shown in
microphone Figure 13.
, Model Figure 11. Microphone Output Attenuation Caused by Input
Q E 7 0 5 2 . Capacitance of Preamp
T h e
impedance of this microphone is 18pF. The microphone screws directly onto
the preamplifier, model 056-852. Typical response for the QE7052 is shown in
Figure 12.
14 15
F. Input Buffer Circuitry G. Weighting Characteristics
The high impedance input circuitry (1 Megohm in series with 0.1 MFD) will The weighting characteristics (frequency response) for A, B, C, and LINear
accept up to a 10 volt RMS signal. With the microphone and preamp removed, are shown in Figure 15. The "A" weighting response emulates the response of
other transducer devices (such as the Quest Model VI-90 Vibration Integrator) the human ear at low levels and is used for most industrial and community
can be interfaced to give a dB readout on the meter. noise measurements. "B" weighting is seldom used. "C" weighting is often
used for measuring noise reduction in hearing protectors and for other
Note that when interfacing other input devices to the Model 1700, the 200 scientific purposes. The "LINear" weighting has a flat frequency response
volt microphone polarization switch located inside of the battery compartment over the range of human hearing and is useful in many applications such as
should be turned OFF for safety. Only use pins 1 and 3 for the AC signal audiometric analysis. It is also normally used when taking octave band
input. NEVER connect to pins 2 and 4. measurements with the optional bandpass filters.
To remove the preamp, keep the preamp housing steady while unscrewing the
black plastic collar below the preamp housing. Turn in a counter-clockwise
direction when viewed from the meter top.
16 17
H. Internal Electrical Noise
Model QE7052, One-Half Inch Microphone:
The maximum measurable SPL of the 1700 Meter is 140 dB with a sinusoidal
input, or 120 dB if measuring a complex signal with a 20 dB crest factor. Octave Weighting Scale
With optional microphones the upper range can be extended past 150 dB. Band
A B C LIN
When used with either the OB-50, OB-100 or OB-300 filter (octave mode), the
specific minimum measurable SPL's when using either the Model QE4170 or the All Pass 35dB 37dB 40dB 48dB
Model QE4146 microphone are as shown in Figure 16. Figure 17 shows the same 31.5 and 63 10dB 25dB 37dB 37dB
information for the model 2700. The inherent noise level is typically at 125 and 250 21dB 27dB 31dB 31dB
least 5 dB below the RMS values shown in each table. 500 and 1K 24dB 25dB 25dB 25dB
2K and 4K 27dB 25dB 25dB 25dB
8K and 16K 29dB 27dB 27dB 30dB
Model QE4170, 1 Inch Microphone:
Figure 17. Minimum measurable SPL's for the Model 2700.
Octave Weighting Scale
Band
A B C LIN I. Tone Burst Response
All Pass 23dB 24dB 27dB 35dB Figures 18 through 22 are plots for each of the response settings of the
31.5 and 63 <0dB 10dB 20dB 22dB meter. They show how the meter responds to a given sinewave input of varied
125 and 250 6dB 12dB 16dB 16dB pulse duration.
500 and 1K 9dB 10dB 10dB 10dB
2K and 4K 11dB 9dB 9dB 10dB SLOW RESPONSE (1000 msec time constant) Figure 18.
8K and 16K 11dB 9dB 9dB 14dB Decay Rate = 4.35 dB per second
Figure 16. Minimum measurable SPL's for the Model 1700 using the Model
QE4170 and the Model QE4146 microphones.
18 19
Figure 21. IMPULSE Response
Figure 19. FAST Response
Figure 20.
PEAK Response
Figure 22.
IMPULSE
Response to
Repeated
Impulses
20 21
VI. SPECIFICATIONS DC Output: 0 to 1.00V DC; 60 dB span. Each 0.167V change equals 10 dB.
Connected equipment should be at least 10K ohms. The output can be shorted
Standards: Model 1700 : Type 1 ; Model 2700 : Type 2 without damaging the meter or changing the meter reading.
ANSI S1.4-1983, IEC 651-1979.
Frequency Range: 4 Hz (-3dB) to 50 kHz (-3dB) on linear weighting, meter
Display: 3-1/2 Digit Liquid Crystal Display with an additional Quasi-Analog only. (Subject to microphone limitations.)
60 dB indicator in 2 dB increments. Level display indicates to 0.1 dB
resolution. Indicators are included for Battery Check, Hold, and Overload Reference Range: 60 to 120 dB Range setting
Indication.
Reference SPL: 94 dB
Modes of Operation: Measures Sound Pressure Level (SPL) and Maximum Level
(MAX). Peak Level (PEAK) and Impulse Level (IMP) can also be measured. Reference Frequency: 1 kHz
Minimum Measurement: Model 1700 Meter only; With Model QE4146 Microphone -- Reference Direction: 0o when using a Free Field Microphone. Sound is
27 dBA. Model 2700 Meter only - 35dBA. Using Linear Weighting with an arriving from directly in front of the microphone diaphragm.
Octave Filter Set; See Figures 16 and 17. The minimum measurement varies
depending on the filter frequency selected. Detector: True RMS
Maximum Measurement: With Model QE4146 or QE7052 Microphone -- 120 dB with Detector Pulse Range: 63 dB
20 dB Crest Factor. (140 dB if measuring a sinusoidal signal.) Overload
indication will occur if upper range is exceeded. Optional microphones for Detector Measuring Range: From 0 dB to 40 dB on the painted scale (when
model 1700 will shift the measurement range upward. measuring a signal with a 20 dB Crest Factor). The extra 20 dB (40 to 60) on
top of the measuring range produces the 20 dB Crest Factor capability.
Frequency Weighting Networks: A, B, C, and Linear. When using a filter set,
any one of the weightings may be selected. Primary Indicator Range / Linearity Range: 60 dB (The range as indicated by
both the dB RANGE switch and the painted 60 dB scale.) Tested with a
Meter Response: Slow, Fast, Impulse, and Peak. (The Peak onset time sinusoidal signal input.
constant is less than 50 microseconds). Peak measurements may be made in
either A, B, C, or Linear Weighting. Level Linearity: Inside the Primary Indicator Range. It is tested on the
Reference Range (60 to 120 dB) with a sinusoidal input signal. Tolerance is
Microphones: Removable precision 1/2 inch prepolarized condenser (electret) +/- 0.7 dB referenced to 94 dB for model 1700, +/- 1.0 dB for model 2700.
microphone is standard. Optional 1/2 inch, one inch, and other microphones
are available for the model 1700 only. Overload Indication: OL appearing in the display indicates overload.
Preamplifier: Directly accepts 0.52" microphone, other sizes with proper Attenuator Accuracy: Referenced from the Reference Range and the Reference
adapter. Removable preamp will drive up to 100 feet of cable with negligible SPL (+34 dB on the painted meter scale).
signal loss.
Model 1700: Within 0.5 dB from 31.5 Hz to 8 kHz. Within 1.0
Model 1700: Preamplifier model 056-856. The input impedance dB from 20 Hz to 12.5 kHz.
is greater than 1 Gohm in parallel with 2 pF.
Model 2700: Within 0.7 dB from 31.5 Hz to 8 kHz.
Model 2700: Preamplifier model 056-852. The input impedance
is greater than 1 Gohm in parallel with 47 pF. Warm-up Time: 30 seconds.
Polarization (1700 only): Regulated 200 V DC within 2% for use with air- Accuracy: Model 1700 : Within 0.5 dB at 25oC; Model 2700 within 0.7 dB at
condenser microphones. The voltage must be switched off when using 25oC. Both models: Within 1.0 dB over the temperature range of -10oC to +50oC.
prepolarized (electret) condenser microphones.
Temperature Range: Operation Temperature Range: -10oC to +50oC. Accuracy
Meter Input: The input impedance is 1 Megohm in series with 0.1 MFD. The over the Operation Temperature is within +/- 0.5 dB. Storage Temperature
maximum sinusoidal input voltage is 10V RMS. Range (less batteries): -20oC to +60oC
Do not exceed the Storage Temperature Range because possible damage to the
AC Output: 3.16 V RMS at full scale (60 dB). (3.8 V RMS maximum) The output unit may result.
impedance is 3.2K ohms. Connected equipment should be at least 10K ohms.
The output can be shorted without damaging the meter or changing the meter
reading.
22 23
Operating Humidity: Over a range of 30 to 90% relative humidity, the VIII. INTRODUCTION TO THE MODELS OB-50, OB-100 and OB-300.
accuracy is within +/- 0.5 dB. Do not exceed 95% relative humidity because
possible damage to the unit may result. The Quest Models OB-50 and OB-100 Octave Filters and OB-300 1/3 - 1/1
Octave Filter are plug-in modules containing a bandpass filter with a
Effect of Magnetic Fields: A magnetic field of 1 Oersted (80A/m) at 60Hz selectable center frequency. The OB-50 and OB-100 meet the most stringent
produces a maximum reading of 40 dB on Linear Weighting. requirements of ANSI S1.11-1986 and IEC R225-1966 for octave band filters.
The OB-100 is a full octave bandwidth active filter with ten selectable
Effect of Electrostatic Fields: Negligible as long as the protection grid is center frequencies from 31.5 Hz to 16 kHz, while the OB-50 has nine bands
kept on the microphone. from 31.5Hz to 8kHz. The OB-300 meets the most stringent requirements of
ANSI S1.11-1986 and IEC R225-1966 for octave and third octave band filters.
Batteries: Two 9-volt alkaline batteries (NEDA 1604A) will provide The OB-300 is an active filter with 33 selectable center frequencies from
approximately 20 hours of continuous operation. (10 hours with optional 12.5 Hz to 20 kHz when in the 1/3 mode and 11 selectable center frequencies
filter set.) from 16 Hz to 16 kHz when in the 1/1 mode. The filters may be operated
manually, or the OB-100 and OB-300 can automatically step through each
Tripod Mount: A threaded insert on back of the meter accepts a standard consecutive band at a user selectable rate.
1/4-20 tripod mounting screw.
Primary uses include frequency analysis for product noise emission,
Size: 3.3 x 8.2 x 1.8 inches (84 x 208 x 47mm) not including the height of material acoustics, community noise, audiometer calibration and analysis of
the preamp. audiometric rooms.
Weight: 24 oz. (680g) including the preamp and batteries. IX. ABOUT THE FILTERS
A. Filter Controls
VII. ACCESSORIES
POWER Switch:
056-981 QC-10 Calibrator; 114dB at 1000 Hz output
ON/OFF (OB-50 only) -- Turns power on or off to the filter only.
056-982 QC-20 Calibrator; Selectable 94dB or 114dB at 250
Hz or 1000 Hz output OFF -- Disconnects the filter circuitry from the attached sound
level meter. With this switch in the off position, the filter does
Calibrator Microphone Adapters not use power from the meter batteries.
056-990 0.52" diameter MANUAL -- Filter frequency selection is performed with two push
056-988 1/4" diameter buttons (START Buttons - ª and «).
059-344 WS-7 Windscreen for 0.52" microphone (package of 3) AUTO -- Unit automatically cycles through the desired filter
frequencies while storing sample information for each frequency
058-115 WS-3 Windscreen for 1" microphone (package of 3) during the RUN mode. (Not on OB-50)
059-045 TP-1 Tripod (Larger - will not fit inside carrying case START (UP and DOWN Arrows)
059-046 TP-2 Tripod (Smaller - fits in carrying case) Allows the user to step through the different bandpass filters. The two
buttons allow manual frequency control (in MANUAL Mode) or frequency
Preamplifier Remote Cables direction control (in AUTO Mode). (Manual mode only on OB-50)
24 25
A. Operational Check
TIME (Not on OB-50)
The Model 1700 should be calibrated as outlined in the meter section of
A screwdriver adjustment controls the automatic cycle time of each the manual while the filter module is OFF. The filter has a fixed gain of
filter frequency from approximately 5 to 30 seconds. approximately 1 (0 dB) at each center frequency and requires no adjustment.
After the meter is calibrated, check the filter for proper operation as
MODE Switch (OB-300 only) follows:
Selects either the 1/3 octave filter set (33 frequencies) or the 1/1 1. Read the calibrator 1 kHz output level. Set the meter dB RANGE
octave filter set (11 frequencies). switch so that the calibrator level will indicate within the upper
20 dB of the meter display. Set the RESPONSE switch to FAST,
B. Filter Connector WEIGHTING switch to LIN and MODE switch to SPL. Turn the POWER
switch to ON.
The 30 pin connector on the top of the filter is used for connecting the
filter to the sound level meter. Figure 23 shows the pinout for the filter 2. Set the filter's switch to ON or MANUAL. If using an OB-300 set
connector. the MODE switch to 1/1. Then use the UP or DOWN arrow buttons on
the filter to select the 1 kHz filter.
26 27
4. Select the desired filter band by pressing the UP or DOWN arrow XII. SPECIFICATIONS - OB-50 and OB-100
buttons. Select the RANGE so that the display reads approximately
20dB below the top of the range. Standards: ANSI S1.11-1986, Order 3, Type 2, Sub-type C and IEC
R225-1966.
AUTO Filter Operation (OB-100 and OB-300)
Center Frequencies:
Set the meter for FAST response time to minimize its settling time after
the filter switches frequencies. Select the first frequency of interest. OB-50 : 9 frequencies from 31.5 Hz to 8 kHz.
(Be sure that the TIME adjustment is set to the desired filter cycle time.) OB-100: 10 frequencies from 31.5 Hz to 16 kHz.
Slide the filter POWER switch to AUTO. To start the sampling sequence Frequency Selection: Full manual control (both models) or automatic
and press the proper direction button. (The ª button causes the frequency to sequential stepping through each frequency (OB-100).
cycle to the next higher frequency, the « button causes the frequency to cycle
to the next lower frequency.) Allow a brief period of time after the Power Source: Sound Level Meter.
frequency changes to allow for measurement settling time.
Size: 3.3 x 2.8 x 1.8 inches (84 x 71 x 47mm)
XI. TECHNICAL INFORMATION - OB-50 and OB-100
Weight: 6 ounces (170 grams)
The OB-50 and OB-100 conform to ANSI S1.11-1986, Order 3, Type 2,
Sub-type C and IEC R225-1966. The normalized passband characteristic of a XIII. TECHNICAL INFORMATION - OB-300
typical octave filter response is depicted in Figure 24.
The OB-300 conforms to ANSI S1.11-1986, Order 3, Type 2, Sub-type C and
The OB-50 and OB-100 filter is flat within 0.5 dB in the passband, with IEC R225-1966. The normalized passband characteristics of both the 1/1 and
the 3 dB down points at approximately .707 fc and 1.414 fc where fc is the 1/3 filter responses are depicted in Figure 25.
center frequency of the band chosen. The fc/2 and 2fc frequencies are down
by approximately 21 dB with the decade points (fc/10 and 10fc) down by The 1/1 filters are flat within 0.5 dB in the passband, with the 3 dB
greater than 70 dB. down points at approximately 0.707 fc and 1.414 fc where fc is the center
frequency of the band chosen. The fc/2 and 2fc frequencies are down by
The block diagram of the filter is shown in Figure 26. approximately 21 dB with the decade points (fc/10 and 10fc) down by greater
than 70 dB.
The 1/3 filters are flat within 0.3 dB in the passband, with the 3 dB
down points at approximately 0.89 fc and 1.12 fc where fc is the center
frequency of the band chosen. The fc/2 and 2fc frequencies are down by
approximately 50 dB.
The block diagram of the OB-300 is shown in Figure 26.
XIV. SPECIFICATIONS - OB-300
Figure 24. Typical OB-50/OB-100 Filter Response Size: 3.3 x 4.2 x 1.8 inches (84 x 107 x 47mm)
28 29
XV. QUEST SERVICE AND WARRANTY POLICY
A. Service Policy
The Quest product you have purchased is one of the finest instruments
available. It is backed by our full one year warranty which seeks complete
customer satisfaction. This is your assurance that you can expect prompt
courteous service for your equipment from the entire Quest service
organization.
Should your Quest equipment need to be returned for repair or recalibration,
please contact the Service Department at 1(800)245-0779 (USA) or Fax
(414)567-4047 for a Return Authorization Number. The RA number is valid for
30 days, and must be shown on the shipping label and purchase order/cover
letter. If you are unable to return instruments in that time call for a new
RA number. Send it prepaid and properly packed in the original shipping
carton directly to Quest Technologies, 510 S. Worthington St., Oconomowoc, WI
53066 U.S.A.
B. Warranty Policy
30 31