APD25BD-6
25 kVA / 20kW
                                                                                                                                         POWERED by BAUDOUIN
  DIESEL GENERATING SET 480/277V,380/220V,220/127V- 60 Hz
                                 MODEL                                                                                         APD25BD-6
                                                                      kVA                                                                 25
                                     Standby
      Power                                                            kW                                                                 20
      Pf. 0.8                                                         kVA                                                                 23
                                        Prime
                                                                       kW                                                                18.4
Standby: Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046.
Prime: Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hours period. In accordance with ISO 8528, ISO 3046.
✓ High quality, reliable and complete power unit
✓ Compact design
✓ Easy start and maintenance possibility
✓ Every generating set is subject to a comprehensive test program which includes full load testing, checking and provision of all
  control and safety shut down functions testing
✓ Fully engineered with a wide range of options and accessories: Canopy, sound proof canopy and off-road trailer
                Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
                                                                                                                                                                         www.aksapowergen.com
    ENGINE
                                                                     BAUDOUIN
Model                                                                                                    4M06G2D0/S
Engine Power Output                                                  kWm                                        25
at rated rpm                                                         HP                                        33.5
Aspiration and Cooling                                                                                        Natural
Total Displacement                                                   Litre                                      2.3
No. of Cylinders and Build                                                                                   4 - Inline
Engine Speed                                                         rpm                                       1800
Bore and Stroke                                                 mm×mm                                         89 × 92
Compression Ratio                                                                                             17.5:1
Governor                                                                                                     Electronic
Fuel Consumption at full load                                        L/hr                                       6.5
Fuel Tank Capacity                                                   Litre                                      60
Oil Capacity                                                         Litre                                     11.5
Coolant Capacity                                                     Litre                                      8.6
Radiator Cooling Air                                             m³/min                                         74
Air Intake – Engine                                              m³/min                                        1.44
Exhaust Gas Flow                                                 m³/min                                        5.64
✓   Heavy duty diesel engine                                                 ✓   Cooling radiator and fan
✓   Four stroke, water cooled, natural                                       ✓   Starter battery (with lead acid) including Rack and Cables
✓   Direct injection fuel system                                             ✓   Flexible fuel connection hoses and manual oil sump drain valve
✓   Electronic Governor system                                               ✓   Industrial capacity exhaust silencer and steel bellows
✓   12Vdc starter and charge alternator                                      ✓   Jacket water heater(at automatic models)
✓   Replaceable fuel filter, oil filter and dry element air filter           ✓   Operation manuals and circuit diagram documents
    ALTERNATOR
Design                                                                       Brushless single bearing, revolving field
Stator                                                                       2/3 pitch
Rotor                                                                        Single bearing, flexible disc
Insulation System                                                            Class H
Standard Temperature Rise                                                    125 - 163°C Continuous
Exciter Type                                                                 Self Excited
Phase Rotation                                                               A (U), B (V), C (W)
Alternator Cooling                                                           Direct drive centrifugal blower fan
AC Waveform Total Harmonic Distortion                                        No load < 1.5%. Non distorting balanced linear load < 5%
Telephone Influence Factor (TIF)                                             <50 per NEMA MG1-22.43
Telephone Harmonic Factor (THF)                                              <2%
✓   Brushless, single bearing system, flexible disc, 4 poles                 ✓ Impregnation with tropicalized epoxy varnish
✓   Insulation class H                                                       ✓ Solid state Automatic Voltage Regulator
✓   Standard degree of protection IP22 (*IP23 is available.)                 ✓ Stator winding with 2/3 pitch for improved harmonics
✓   Self-exciting and self-regulating
                                                                                                                                  www.aksapowergen.com
 CONTROL SYSTEM
Control supervision and protection panel is mounted on the genset base frame.
The control panel is equipped as follows:
1. Auto Mains Failure Control Panel
  Panel equipments:
✓ Control with AMF module
✓ Static battery charger
✓ Emergency stop push button
                                                                                                            DSE 6120
a) Generating set control module DSE6120 features:                               c) Alarms:
✓ The module is used to monitor main supply and                                  ✓   Over and Under Speed
  starts and stops of a standby generating set                                   ✓   Low and High Battery Volt.
✓ Micro-processor based design                                                   ✓   Start and Stop Failure
✓ Automatic control of main and generator contactors                             ✓   Charge fail
✓ Monitors engine performance and AC power output LED                            ✓   Over Current
  alarm indication                                                               ✓   Under / Over Generator Voltage
✓ Front panel configuration of timers and alarm trip points                      ✓   Low Oil Pressure
✓ 4 configurable analogue/digital inputs, 8 configurable digital inputs          ✓   Emergency stop
✓ 6 configurable DC outputs                                                      ✓   High engine temperature
✓ Easy push button control                                                       d) LED indications
  STOP/RESET - MANUAL - AUTO - TEST - START                                      ✓   Mains available
b) Metering via LCD display:                                                     ✓   Generator available
✓   Generator Volts (L-L / L-N)                                                  ✓   Mains on load
✓   Generator Kva                                                                ✓   Generator on load
✓   Generator kW
✓   Generator Cos (Φ)
✓   Engine oil pressure (Psi-Bar)
✓   Generator Ampere (L1,L2,L3)
✓   Engine temperature (℃ & ℉)
✓   Generator Frequency (Hz)
✓   Plant battery volts
✓   Engine hours run
✓   Mains Volts (Ph-Ph / Ph-N)
2. Power Outlet Terminal Board Mounted on the Gen-set Base Frame
 OPTIONAL EQUIPMENTS
Diesel Engine                                      Panel                                Accessories
✓ Oil heater                                       ✓   Charge ammeter                   ✓   Bulk fuel tank
Alternator                                         ✓   Transfer Switch 3Pole            ✓   Automatic filling system
✓ 3/4 Pole Output Circuit Breaker                  ✓   Transfer Switch 4 Pole           ✓   Fuel-water separator filter
✓ Anti-condensation Heater                         ✓   Earth Fault ,single set          ✓   Low fuel level alarm
                                                                                        ✓   Residential silencer
                                                                                        ✓   Enclosure or sound proof canopy
                                                                                        ✓   Trailer
                                                                                        ✓   Manual oil drain pump
                                                                                        ✓   Tool kit for maintenance
                                                                                                                 www.aksapowergen.com
CHASSIS
✓   The complete gen-set is mounted as whole on a heavy-duty fabricated, steel base frame
✓   Anti-vibration pads are fixed between the engine/alternator feet and the base frame
✓   Base frame design incorporates an integral fuel tank (Up to 1000 kVA)
✓   The generating set can be lifted or carefully pushed / pulled by the base frame
✓   Dial type fuel gauge and drain plug on the fuel tank
✓   Forklift pockets within base frame (up to 500kVA)
DIMENSIONS
                                                        OPEN TYPE
DIMENSIONS (L×W×H)                                          mm                           1696×892×1003
DRY WEIGHT                                                  kg                                525
                                         SOUND ATTENUATED TYPE
DIMENSIONS (L×W×H)                                          mm                           1980×950×1205
DRY WEIGHT                                                  kg                                655
CANOPY
✓   All canopy parts are designed with modular principles        ✓   Exhaust silencer is protected against environment influences
✓   Without welding assembly                                     ✓   Thermally insulated engine exhaust system
✓   Doors on each side                                           ✓   Emergency stop push button is installed outside of the canopy
✓   All metal canopy parts are painted by electrostatic          ✓   Easy lifting and moving
    polyester powder paint                                       ✓   Easy maintenance and operation
                                                     Aksa Power Generation
                      Ruzgarlibahce Mahallesi - Özalp Cikmazi No:10 34805 Kavacik Beykoz - Istanbul / Turkey
                                   Tel:+90 212 444 46 30      E-mail: aksa@aksapowergen.com
                                                    www.aksapowergen.com
                                 Aksa Power Generation is a member of              www.aksa.com.tr