0% found this document useful (0 votes)
49 views3 pages

Brochure AMH

Uploaded by

mileyhannah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views3 pages

Brochure AMH

Uploaded by

mileyhannah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

BI O MÉR I EUX

VIDAS®
ANTI-MÜLLERIAN HORMONE
On-hand testing for greater patient comfort
Did you know? VIDAS®
1/6 couples worldwide experience some form of infertility
Polycystic Ovary Syndrome (PCOS) affects 5-10% of women
(1)

Anti-Müllerian Hormone
of reproductive age (2)
On-hand quality testing for confident decisions
In 30 years, the success rate of IVF has increased
from 10% to above (3)
30% Reliability and robustness
Greater reliability through patented proprietary raw materials

Anti-Müllerian Hormone (AMH) testing ➔ Reliable results when compared with an existing automated method*
➔ Minimal impact of pre-analytical stage on test results:
for ovarian function assessment in women ≤ 8 hours at +18/+25°C ≤ 5 days at +2/+8°C ≤ 3 freezing-thawing cycles
in closed primary tube when aliquoted
AMH FEATURES ≤ 3 cycles
≤ 8 hours ≤ 5 days
Stable over the menstrual cycle Sensitive to conformational change

LH (mIU/mL) AMH (ng/mL)


in samples (5) ❄ ❄ ❄
35 FSH (mIU/mL) 6 More accurate than Antral Follicular Count
30 5 (AFC)
25
4
Inter-operator variation makes AFC subjective
VIDAS®: an easy-to-use

20
3
15 ● AMH provides quantitative objective results (6) VIDAS® COMMUNITY:
benchtop platform
2
10

0
1

0
A key test within the diagnostic work-up partnering over
30 000 users
-14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14
Days
Circulatory patterns of FSH, LH and AMH during the menstrual
● Just load & go
cycle of young healthy women (4)Day 0 = day of LH surge ● Limited calibration and maintenance
● Compact instrument: easily fits into your fertility center worldwide
or laboratory

24/7 availability for your patients’ comfort


A COMPLETE SOLUTION ON
YOUR VIDAS® INSTRUMENT
1 patient = 1 test for maximum flexibility
HORMONE SEROLOGY ● On-demand testing
ASSAYS PANELS ● Results during the consultation
CLINICAL APPLICATIONS AMH HEPATITIS ➔ Less patient stress
As an indicator of the ovarian follicle reserve, Detection of ovarian dysfunction ESTRADIOL HIV ➔ Immediate integration of AMH results
AMH is useful in different contexts all along (PCOS, Premature ovarian failure…): FSH TORC into the full diagnostic work-up
the reproductive lifespan: The use of AMH rather than Follicle Stimulating LH
➔ Treatment optimization
Personalization of infertility management Hormone (FSH) or Luteinizing Hormone (LH) HCG
(IVF/ART): provides direct, more accurate assessment PROLACTIN
➔ No unnecessary ovarian stimulation
Assessment of ovarian reserve for infertility of ovulation. PROGESTERONE
investigations Monitoring of ovarian damage(surgery, TESTOSTERONE
Help to select the best stimulation protocol gonadotoxic therapies) THYROID PANEL
➔ Adapt treatment First-choice marker to detect the decline of * See package insert
➔ Avoid unnecessary stimulation the ovarian reserve.
➔ Reduce risk of hyperstimulation syndrome
BI O MÉR I EUX

AVAILABLE ON
VIDAS® INSTRUMENTS:
VIDAS®, MINI VIDAS®
AND VIDAS® 3

VIDAS® AMH

Reference number 417011

Tests / kit 30

Time to result 35 min

Sample type Serum, Plasma (Li Hep)

Sample volume 200 µL


the BIOMÉRIEUX logo and VIDAS are used, pending and/or registered trademarks belonging to bioMérieux, or one of its subsidiaries or one of its companies.

Units ng/mL - pmol/L


Any other trademark is the property of its respective owner. / bioMérieux S.A. RCS Lyon 673 620 399 / Printed in France / thera/ RCS Lyon B 398 160 242
12-18/ 9316051 008/GB/B / Document and/or pictures not legally binding. Modifications by bioMérieux can be made without prior notice / BIOMÉRIEUX,

Measuring range 0.02 – 9.00 ng/mL

Calibration & Control frequency 28 days

REFERENCES
1. https://www.eshre.eu/Guidelines-and-legal/ART-fact-sheet
2. https://www.pcosfoundation.org/
3. https://www.sart.org/History_of_IVF/
4. La Marca et al Human Reproduction 2006
5. Rustamov O et al Human Reproduction 2012
6. Anderson RA et al Fertility and Sterility 2015

bioMérieux S.A. • 69280 Marcy l’Etoile • France • Tel.: + 33 (0)4 78 87 20 00 • Fax: +33 (0)4 78 87 20 90
www.biomerieux.com • www.biomerieux-diagnostics.com-

You might also like