Growatt8000~10500MTLP-S

· Maximum efficiency of 97.8%

· Compact design

· 3 MPP tracker

· Integrated DC switch

· UL1741 SA, CA Rule21 compliant

www.ginverter.com
Datasheet 8000MTLP-S 9000MTLP-S 10500MTLP-S

Input data (DC)


Max. recommended PV
power(for module STC) 9600W 10800W 12000W
Max. DC voltage 600V 600V 600V
Start voltage 140V 140V 140V
DC rated voltage 360V 360V 360V
MPP voltage range 110-500V 110-500V 110-500V
No. of MPP trackers 3 3 3

No. of PV strings per MPP trackers 1/1/2 1/1/2 1/1/2


Max. input current per MPP trackers 12.5A/12.5A/25A 12.5A/12.5A/25A 12.5A/12.5A/25A
Max. short-circuit current per 32A 32A 32A
MPP trackers

Output data (AC)


AC nominal power 8000W 9000W 10000W
Max. AC apparent power 8000VA 9900VA 10000VA
Nominal AC voltage 220V 220V 220V/230V
AC voltage range 184V~276V 184V~276V 184V~276V
AC grid frequency 60Hz 60Hz 50Hz/60Hz
AC grid frequency range 55~65Hz 55~65Hz 45~65Hz
Max. output current 36.2A 40.9A 45.7A

Power factor(@nominal power) >0.99 >0.99 >0.99

Adjustable power factor 0.8leading~0.8lagging 0.8leading~0.8lagging 0.8leading~0.8lagging

THDi <3% <3% <3%


AC grid connection type L/N/PE L1/L2/N/PE L/N/PE L1/L2/N/PE L/N/PE L1/L2/N/PE

Efficiency
Max.efficiency 98.1% 98.1% 98.1%
Euro-eta 97.6% 97.6% 97.6%

Protection Devices
DC reverse-polarity protection yes yes yes
DC switch yes yes yes
DC Surge protection Type II Type II Type II
Insulation resistance monitoring yes yes yes
AC surge protection Type III Type III Type III
AC short-circuit protection yes yes yes
Ground fault monitoring yes yes yes
Grid monitoring yes yes yes

Anti-islanding protection yes yes yes

Residual-current monitoring unit yes yes yes

AFCI protection opt opt opt

General Data
Dimensions (W / H / D) 355*620*260mm 355*620*260mm 355*620*260mm

Weight 28kg 28kg 28kg


Operating temperature range –25 °C ... +60 °C(>45°C derating) –25 °C ... +60 °C(>45°C derating) –25 °C ... +60 °C(>45°C derating)
Noise emission (typical) ≤ 35 dB(A) ≤ 35 dB(A) ≤ 35 dB(A)
Altitude 4000m 4000m 4000m
Internal consumption at night <1W <1W <1W
Topology Transformerless Transformerless Transformerless
Cooling Nature Convection Nature Convection Nature Convection
Electronics protection degree IP65 IP65 IP65

Relative humidity 0~100% 0~100% 0~100%


DC connection H4/MC4(optional) H4/MC4(optional) H4/MC4(optional)

AC connection Cable gland+OT terminal Cable gland+OT terminal Cable gland+OT terminal

Features
Display LCD LCD LCD
Interfaces: RS485/WIFI/GPRS/4G/RF yes/opt/opt/opt/opt yes/opt/opt/opt/opt yes/opt/opt/opt/opt
Warranty: 5 years/10 years yes/opt yes/opt yes/opt

NBR16149, NBR16150, INMETRO, EN61000-6-2, EN61000-6-3, IEEE1547, FCC, IEC/EN62109-1, IEC/EN62109-2, UL1741

GROWATT NEW ENERGY TECHNOLOGY Co.,LTD A: No.28 Guangmming Road, Longteng Community, Shiyan, Baoan District, Shenzhen, P.R.China.
T: + 86 755 2747 1900 F: + 86 755 2749 1460 E: info@ginverter.com