S Series Sockets

SY / SM
SH / SR

Various terminal styles available such as


standard teminals, finger-safe types and
Push-in types.

• See website for details on approvals and standards.

Front Wiring Rear Wiring


Model No. of Poles Styles Page Model No. of Poles Styles Page

SY Standard SY
Slim Solder
2, 4 H-058 2, 4 H-064
cost-performance PC board
Finger-safe

SU SM
Solder
2 ,4 Push-in H-058 2 H-064
PC board

SM Standard SH
Slim Solder
2 H-058 1, 2, 3, 4 H-065
cost-performance PC board
Finger-safe

SH Standard SR
Slim Solder
1, 2, 3 4 H-059 2, 3 H-065
cost-performance Wire-warp
Finger-safe

SR
Standard
2, 3 H-059
Finger-safe

H-057 For
Formore
moreinformation,
information,visit
visithttp://apac.idec.com
http://eu.idec.com
S Series Relay Sockets

Relays & Sockets


Front Wiring Sockets
Package Quantity: 1
Part No. Rated Insulation IDEC Applicable
Mounting No. of Terminal Screw Recommended
Shape Style Color (Ordering Part Approvals Voltage/ Relays/Timers
Style Poles Applicable Wire Tightening Torque
No.) Rated Current (example)
APEM

Switches &
M3 UL,CSA, 250V RY2S Pilot Lights
2 Standard Black SY2S-05B 0.6 to 1.0N·m
2mm2max. TUV 7A RY22S
Control Boxes

Emergency
Stop Switches
M3 UL,CSA, 250V RY2S Enabling
2 Finger-safe Black SY2S-05C 0.6 to 1.0N·m
2mm2max. TUV, CE 7A RY22S Switches

Safety Products
RY4S
RY42S Explosion Proof
M3 UL,CSA, 250V
4 Standard Black SY4S-05B 0.6 to 1.0N·m RU4S
2mm2max. TUV 7A
RU42S Terminal Blocks
GT5Y-4
Relays & Sockets
RY4S
SY / SN RY42S Circuit
250V Protectors
RU4S
7A
RU42S Power Supplies
M3 UL,CSA,
4 Finger-safe Black SY4S-05C 0.6 to 1.0N·m GT5Y-4
2mm2max. TUV, CE
LED Illumination
250V RM2S
7A RU2S
Controllers
(UL,10A) GT5Y
Operator
Interfaces
M3 UL,CSA, 300V
4 Standard Black SN4S-05D 0.8N·m Sensors
2.5mm2max. CE 6A RU4S
RU42S
AUTO-ID
RY4S
RY42S
M3 UL,c-UL 250V GT5Y-4
4 Finger-safe Black SY4S-05DF 0.6 to 1.0N·m
1.25 mm2 (2mm2max.) CE 6A

Relays
Solid wire / stranded wire
0.14 to 1.5mm2, Sockets
AWG26 to 16 300V AC/DC RU2S
2 Push-in Black SU2S-21L — c-UL, CE
12A GT5Y-2 DIN Rail
Stranded wire with ferrule
Products
(without insulated cover)
SU 0.5 to 1.5mm2,
AWG20 to 16
RU4S
Stranded wire with ferrule 300V AC/DC
4 Push-in Black SU4S-21L (with insulated cover) — c-UL, CE RU42S
8A
0.14 to 1.0mm2, GT5Y-4 SJ
AWG26 to 18
DF

M3 UL,CSA, 250V SU
2 Standard Black SM2S-05B 0.6 to 1.0N·m
2mm2max. TUV 7A
S

250V
M3 UL,CSA,
2 Finger-safe Black SM2S-05C 0.6 to 1.0N·m 7A
2mm2max. TUV,CE
(UL,TÜV 10A)
RM2S
SM / SN RU2S
GT5Y-2
M3 UL,CSA, 250V
2 Standard Black SN2S-05D 0.8N·m
2.5mm2max. CE 10A

M3
SM2S- UL,c-UL 250V
2 Finger-safe Black 1.25 mm2 0.6 to 1.0N·m
05DF CE 10A
(2mm2max.)

Download
Download
catalogs
catalogs
and CAD
and CAD
fromfrom
http://eu.idec.com/downloads
http://apac.idec.com H-058
Relays & Sockets
S Series Relay Sockets

 Package Quantity: 1
Rated Insulation IDEC Applicable
Mounting No. of Part No. Terminal Screw Recommended
Shape Style Color Approvals Voltage/ Relays/Timers
Style Poles (Ordering Part No.) Applicable Wire Tightening Torque
Rated Current (example)

M3.5 1.0 to 1.3N·m 250V


UL, CSA,
1 Standard Black SH1B-05B (coil teminal: M3) (M3 screw: 10A
TUV
2mm2max. 0.6 to1.0N·m) (coil teminal 7A)

APEM RH1B

Switches & M3.5 1.0 to 1.3N·m 250V


UL, CSA,
Pilot Lights 1 Finger-safe Black SH1B-05C (coil terminal: M3) (M3 screw: 10A
TUV, CE
2mm2max. 0.6 to 1.0N·m) (coil teminal 7A)
Control Boxes

Emergency
Stop Switches
Enabling M3.5 UL, CSA, 250V
2 Standard Black SH2B-05B 1.0 to 1.3N·m
Switches 2mm2max. TUV 10A
Safety Products

Explosion Proof
M3.5 UL, CSA, 250V
2 Finger-safe Black SH2B-05C 1.0 to 1.3N·m RH2B
Terminal Blocks 2mm2max. TUV, CE 10A

Relays & Sockets

Circuit
Protectors Slim, cost- M3.5 250V
SH 2 Black SH2B-05D 1.0 to 1.3N·m UL, c-UL
performance 2mm2max. 10A
Power Supplies

LED Illumination

Controllers M3.5 UL, CSA, 250V


3 Standard Black SH3B-05B 1.0 to 1.3N·m
2mm2max. TUV 10A
Operator
Interfaces
RH3B
Sensors
M3.5 UL, CSA, 250V
AUTO-ID 3 Finger-safe Black SH3B-05C 1.0 to 1.3N·m
2mm2max. TUV, CE 10A

M3.5 UL, CSA, 250V


Relays 4 Standard Black SH4B-05B 1.0 to 1.3N·m
2mm2max. TUV 10A
Sockets
RH4B
DIN Rail
Products M3.5 UL, CSA, 250V
4 Finger-safe Black SH4B-05C 1.0 to 1.3N·m
2mm2max. TUV, CE 10A

SJ
M3.5 UL, CSA, 250V RR2P
2 Standard Black SR2P-05B 1.0 to 1.3N·m
DF 2mm2max. TUV 10A GT5P

SU

S RR2P
SR M3.5 UL, CSA, 250V
2 Standard Black SR2P-06B 1.0 to 1.3N·m GT3 (8 Pin)
(8 pin) 2mm2max. TUV 10A
GT5P

M3.5 UL, CSA, 250V RR2P


2 Finger-safe Black SR2P-05C 1.0 to 1.3N·m
2mm2max. TUV, CE 10A GT5P

M3.5 UL, CSA, 250V RR3P, RR3PA


3 Standard Black SR3P-05B 1.0 to 1.3N·m
2mm2max. TUV 10A GT3 (11 Pin)

SR M3.5 UL, CSA, 250V RR3P, RR3PA


3 Standard Black SR3P-06B 1.0 to 1.3N·m
(11 pin) 2mm2max. TUV 10A GT3 (11 Pin)

M3.5 UL, CSA, 250V RR3P, RR3PA


3 Finger-safe Black SR3P-05C 1.0 to 1.3N·m
2mm2max. TUV, CE 10A GT3 (11 Pin)

H-059 For
Formore
moreinformation,
information,visit
visithttp://apac.idec.com
http://eu.idec.com
S Series Relay Sockets

Relays & Sockets


 Package Quantity: 1
Part No. Recommended Rated Insulation IDEC Applicable
Mounting No. of Terminal Screw
Shape Style Color (Ordering Part Tightening Approvals Voltage/ Relays/Timers
Style Poles Applicable Wire
No.) Torque Rated Current (example)
Black SJ1S-05B UL, 250V
1 Standard M3 2mm2max 0.6 to 1.0N·m
White SJ1S-05BW CSA 12A

Black SJ1S-07L UL,


250V
1 Finger-safe M3 2mm2max 0.6 to 1.0N·m CSA,
White SJ1S-07LW 12A APEM
CE
RJ1S
Solid wire / stranded wire Switches &
0.14 to 1.5mm2, AWG26 to 16 Pilot Lights
Stranded wire with ferrule (with insulated cover) c-UL, 300V AC/DC
1 Push-in Black SJ1S-21L 0.5 to 1.5mm2, AWG20 to 16 – Control Boxes
CE 12A
Stranded wire with ferrule (with insulated cover) Emergency
0.14 to 1.0mm2, AWG26 to 18 Stop Switches
SJ Enabling
Black SJ2S-05B UL, 250V Switches
2 Standard M3 2mm2max 0.6 to 1.0N·m
White SJ2S-05BW CSA 8A
Safety Products
Black SJ2S-07L UL,
250V Explosion Proof
2 Finger-safe M3 2mm2max 0.6 to 1.0N·m CSA,
White SJ2S-07LW 8A
CE
RJ2S Terminal Blocks
Solid wire / stranded wire
0.14 to 1.5mm2, AWG26 to 16
Relays & Sockets
Stranded wire with ferrule (with insulated cover) c-UL, 300V AC/DC
2 Push-in Black SJ2S-21L 0.5 to 1.5mm2, AWG20 to 16 –
CE 8A Circuit
Stranded wire with ferrule (with insulated cover) Protectors
0.14 to 1.0mm2, AWG26 to 18
Power Supplies
UL,
DIN rail 250V RF1V-2A2B,
4 Black SF1V-4-07L 0.7 to 1.65mm2 0.5 to 0.8N·m CSA, LED Illumination
mount 6A RF1V-3A1B
TUV, CE
SF1V
UL, RF1V-4A2B, Controllers
DIN rail 250V
6 Black SF1V-6-07L 0.7 to 1.65mm2 0.5 to 0.8N·m CSA, RF1V-5A1B, Operator
mount 6A
TUV, CE RF1V-3A3B Interfaces

• See SJ series pages of the catalog for SJ Series dimensions. •See E-189 for SF1V dimensions Sensors

AUTO-ID
Accessories
Applicable Hold-down Springs
IDEC Applicable Relays/ Leaf Spring (2 pcs) Relays
Front Wiring Socket
Timers (example) SFA-202 SFA-101 SFA-203 SFA-502 SFA-503 SFA-511
Sockets
SY2S-05B, SY2S-05C RY2S, RY22S  
DIN Rail
RU4S, RU42S   Products
SY4S-05B
SY4S-05C RY4S, RY42S  
GT5Y-4 
RU4S, RU42S 
SN4S-05D
SY4S-05DF RY4S, RY42S  SJ
GT5Y-4 
DF
RU2S  
SM2S-05B
SM2S-05C RM2S   SU
GT5Y-2 
S
RU2S 
SN2S-05D
SM2S-05DF RM2S 
GT5Y-2 
RU2S  
SU2S-11L RM2S  
GT5Y-2 
RU4S, RU42S  
SU4S-11L RY4S, RY42S  
GT5Y-4 
SH1B-05B, SH1B-05C RH1B  
SH2B-05B, SH2B-05C RH2B  
SH2B-05D RH2B 
SH3B-05B, SH3B-05C RH3B  
SH4B-05B, SH4B-05C RH4B  
SR2P-05B, SR2P-05C GT5P 
GT3 (8 pin) 
SR2P-06B
GT5P 
SR3P-05B, SR3P-05C GT3 (11 pin) 
SR3P-06B GT3 (11 pin) 

Download
Download
catalogs
catalogs
and CAD
and CAD
fromfrom
http://eu.idec.com/downloads
http://apac.idec.com H-060
Relays & Sockets
S Series Relay Sockets

Accessories
 When ordering, specify the Ordering No.
Style Shape Part No. Ordering No. Package Quantity

SFA-202 SFA-202PN20 20 (10 pairs)

APEM
20
Switches & SFA-101 SFA-101PN20
(10 pairs)
Pilot Lights

Control Boxes
20
Emergency SFA-203 SFA-203PN20
Stop Switches (10 pairs)
Enabling Wire Spring
Switches
For Relays 20
Safety Products SFA-502 SFA-502PN20 (10 pairs)
Stainless
Explosion Proof
20
Terminal Blocks SFA-503 SFA-503PN20 (10 pairs)
Stainless
Relays & Sockets

Circuit For Timer 20


Protectors SFA-511 SFA-511PN20 (10 pairs)
Power Supplies Stainless

LED Illumination • Two Leaf springs are used for one relay.

Controllers

Operator Dimensions All dimensions in mm


Interfaces

Sensors (1) SY / SN
AUTO-ID
SY2S-05B SY2S-05C
When using When using
17 BAA/BAP: 28.5 BAA/BAP: 32.5 2-ø4.2 Mounting Holes
Terminal 17.2 (or M4 Tapped Holes)
6 DIN Rail 25 Terminal
DIN Rail (BAA/BAP)
18 Arrangement 6
M3 Terminal (BAA/BAP) M3 Terminal Arrangement
Screw 2-ø4.2 Mounting Holes 8 5 Screw 8 5
8 5
16
(or M4 Tapped Holes) 4 1
44 14

ø5 4 1
Relays
4 1

42 12
Ring crimping
4.2

terminals cannot be used.


62

45

64

46

Sockets 16
4.2

5.9max.
3.2min.

14 13 14 13
DIN Rail 4max. 4.8min. A2

14
A1

13

12 9
2

41 11

12 9
Products ø3.2min. 12 9

16 14.5
(Top View)
2

16 18.2 (Top View)


1.6

20 25 5.9max.
20 29 4max. 5.8min.

SJ
SY4S-05B SY4S-05C
When using When using
30 BAA/BAP: 28.5 BAA/BAP: 32.5 2-ø4.2 Mounting Holes
DF (or M4 Tapped Holes)
DIN Rail (BAA/BAP)

6 18 Terminal
Arrangement 30 25
0.7

DIN Rail (BAA/BAP) Terminal


M3 Terminal 6 M3 Terminal
SU Screw 2-ø4.2 Mounting Holes 8 7 6 5 Arrangement
8 7 6 5

4 3 2 1 Screw 26
4 3 2 1 (or M4 Tapped Holes) 8 7 6 5

S ø5.5 18 4 3 2 1
Ring crimping
62

45

4.2

26 terminals cannot be used.


4.2

46
64

1 1

4max. 4.8min.
4 3
5.9max.
3.2min.

1 1 1
9
14 13
2 1 0

12 11 10 9
ø3.2min.
18.5
2.0

(Top View)
3

26 25 5.9max.
18.2 (Top View)
26
1.6

29 4max. 5.8min.

• See DF relay socket pages of the product catalog for SN4S-05D, SY4S-05DF dimensions.

H-061 For
Formore
moreinformation,
information,visit
visithttp://apac.idec.com
http://eu.idec.com
S Series Relay Sockets

Relays & Sockets


Dimensions All dimensions in mm

(2) SU 43 Terminal Arrangement 43 Terminal Arrangement

SU2S-21L (12)41 (9)11


SU4S-21L (12)41 (11)31 (10)21 (9)11

(8)44 (5)14
(4)42 (1)12 (8)44 (7)34 (6)24 (5)14
(4)42 (3)32 (2)22 (1)12

102

102
APEM

(14)A2 (13)A1
Switches &
(14)A2 (13)A1
Jumper Port Pilot Lights
• For specifications, • For specifications, Jumper Port
(Top View) (Top View)
see SU series Push-in pages see SU series Push-in pages Control Boxes
of the product catalaog. of the product catalaog.
Emergency
Stop Switches
Enabling
Switches
31 31
(3) SM / SN Safety Products

SM2S-05B When using SM2S-05C When using Explosion Proof


30 BAA/BAP: 28.5 BAA/BAP: 32.5

DIN Rail (BAA/BAP)


30 2-ø4.2 Mounting Holes
6 18 Terminal M3 (or M4 Tapped Holes) Terminal Blocks
6 25 Terminal
Arrangement Terminal
0.7

M3 Terminal Arrangement
DIN Rail (BAA/BAP) Screw
Screw 8 5
8 7 6 5 ø5.5 26
8 5 Relays & Sockets
4 3 2 1
2-ø4.2 Mounting Holes 4 1 18 4 1
(or M4 Tapped Holes) Circuit
Ring crimping

4.2
terminals cannot be used. Protectors
62

45

64

46
26

5.9max.
3.2min.
Power Supplies
4.2

1 1
4 3

14 13 14 13
1
2
1
1
1
0
9
4max. 4.8min. 12 9
12 9 LED Illumination

2
18.5 ø3.2min. (Top View)
(Top View) 18.2
3

26
1.6

26 25 5.9max. 29 4max. 5.8min. Controllers

• See DF series pages of the product catalog for SM2S-05DF, SN2S-05D dimensions. Operator
Interfaces
(4) SH Sensors
SH1B-05B
When using AUTO-ID
BAA/BAP: 28.5
17
Terminal
8 M3.5 Terminal 18 Arrangement
Screw DIN Rail (BAA/BAP)
5
2-ø4.2 Mounting Holes 1
4.2

(or M4 Tapped Holes)


Relays
67

47

16 Sockets
M3 Terminal 14 13
Screw 9 DIN Rail
16 14.5 5.5min. 4.8min. Products
2.5

20 25 4.5max. 4max. (Top View)

ø3.6min. ø3.2min.
7.9max. 5.9max.

(For terminals 1, 5, and 9) (For terminals 13 and 14) SJ

SH1B-05C SH2B-05B DF
When using Terminal When using
17 BAA/BAP: 33 2-ø4.2 Mounting Holes BAA/BAP: 28.5
7 (or M4 Tapped Holes) Arrangement
M3.5 Terminal 25 SU
Screw 5 22 25 Terminal
5
8 M3.5 Terminal 14.5 Arrangement
ø5 DIN Rail 16
1
DIN Rail (BAA/BAP)
1
14

(BAA/BAP) Screw 8 5
S
12
2-ø4.2 Mounting Holes
4 1
(or M4 Tapped Holes)
4.2

4.2
48
69

67
47
67
5.9max.
3.2min.
6.9max.
3.6min.

14 13

9
26
A A

4.5max. 5.5min.
2 1
1 1

(Top View) 14 13
4 3
11

9
ø3.6min. 12 9

18.7 4.5max. 6.5min. 4max. 5.8min. 26 7.9max. (Top View)


2.5

2.5

16
1.7

20 29.5 30
(For terminals 1, 5, and 9) (For terminals 13 and 14)

SH2B-05C SH2B-05D
When using Terminal
22 28
BAA/BAP: 33 2-ø4.2 Mounting Holes 2-M3 or M4 Arrangement
7 M3.5 Terminal (or M4 Tapped Holes) Terminal 1.8 6.7 2.2 19.5 (or 4.5 Mounting Holes)
25
8 5
Screw DIN Rail Arrangement 4 1
44 14

ø5 (BAA/BAP) 8 5 4 4 1
8 5
26
4 1

42 12
4.2

4 1 8 5
68 ±0.3
35.3
68
78
69

49

Ring crimping
terminals cannot be used. SH2B−05D
A2 A1

1
14 13
2 9
M3.5
6.9max.
3.6min.

41 11
1 1
14 13 4 3
Terminal
12 9

26 18.7
12 9
Screw 19 ±0.2
6

8 4.3max. 5.8min. 12 9
1.7

30 4.5
29.5 (Top View) 30
19 6.6max. 14 13
ø3.6min.
4.5max. 6.5min.
(Top View)

Download
Download
catalogs
catalogs
and CAD
and CAD
fromfrom
http://eu.idec.com/downloads
http://apac.idec.com H-062
Relays & Sockets
S Series Relay Sockets

Dimensions All dimensions in mm

SH3B-05B SH3B-05C
When using When using 2-ø4.2 Mounting Holes

DIN Rail (BAA/BAP)


32 BAA/BAP: 28.5 BAA/BAP: 33 (or M4 Tapped Holes)
32 M3.5
M3.5 Terminal
8 18 7 Terminal Screw 25 Terminal
Terminal Screw DIN Rail (BAA/BAP) Arrangement
8 6 5
Arrangement
2-ø4.2 Mounting Holes 8 6 5 44 24 14

ø5 8 6 5
(or M4 Tapped Holes) 4 2 1
4 2 1
36
42 22 12
4 2 1
4.2

4.2
Ring crimping

49
69
67

47
APEM
36 terminals cannot be used.
Switches &
A2 A1

4.5max. 5.5min. 14 13

6.9max.
3.6min.
14 13

14 13
Pilot Lights
41 21 11

12 10 9 12 10 9

12 10 9
(Top View) 36 18.7

1.7
Control Boxes 36 14.5 7.9max. (Top View)
2.5

40
40 25 ø3.6min. 29.5
Emergency
Stop Switches 4.5max. 6.5min.
Enabling
Switches
SH4B-05B SH4B-05C
Safety Products When using When using
50 BAA/BAP: 28.5 BAA/BAP: 33
42 2-ø4.2 Mounting Holes
42 Terminal (or M4 Tapped Holes)
8 18 DIN Rail (BAA/BAP) 7 25
Explosion Proof Arrangement
DIN Rail
2-ø4.2 Mounting Holes Terminal
8 7 6 5 8 7 6 5
(BAA/BAP)
(or M4 Tapped Holes) Arrangement
Terminal Blocks
44 34 24 14

ø5
4.2

4 3 2 1
46
4 3 2 1

42 32 22 12 8 7 6 5

4.2
4 3 2 1
67

Ring crimping
47

Relays & Sockets

69
46

49
terminals cannot be used.
14 13
Circuit
2.5

4.5max. 5.5min.

6.9max.
3.6min.
A2 A1

Protectors M3.5 ø3.6min.


12 11 10 9 14 13
14 13
Terminal (Top View)
41 31 21 11

Power Supplies Screw 14.5 7.9max.


12 11 10 9
12 11 10 9

25 18.7 (Top View)


46
1.7

LED Illumination 29.5


50 4.5max. 6.5min.

Controllers

Operator
(5) SR
Interfaces SR2P-05B SR2P-06B
When using
Sensors BAA/BAP: 32 40 When using
8 BAA/BAP: 25.5 Terminal
36 DIN Rail (BAA/BAP) Arrangement
AUTO-ID 27 DIN Rail (BAA/BAP) Terminal
8 M3.5 Terminal 2-ø4.2 Mounting Holes 6 5 4 3
M3.5 Terminal 16.5 Arrangement (or M4 Tapped Holes)
2-ø4.2 Mounting Holes Screw
Screw 5 4
(or M4 Tapped Holes)
ø25
60

6 3
33
ø25
52

33

52

29 M4.2 Terminal
7 8 1 2
Relays 7 2 Screw 5max. 5min.
8 1
18 (Top View)
33
1

M4.2 Terminal 4.5max. 5min. ø3.6min.


Sockets 29 Screw 28.5 (Top View) 22
3
3

7.9max.
DIN Rail 7.9max.
Products ø3.6min.

SR2P-05C SR3P-05B
SJ 36 When using 42
When using
7 BAA/BAP: 33.5 M3.5 BAA/BAP: 32.5
Terminal 8 Terminal Terminal
DF Screw DIN Rail (BAA/BAP)
Arrangement
Arrangement 2-ø4.2 Mounting Holes
DIN Rail 2-ø4.2 Mounting Holes 7 6 5
5 4 ø5 (BAA/BAP) (or M4 Tapped Holes) 5 4 (or M4 Tapped Holes)
SU 6 3
8 4
6 3
ø27
33
52

S 29 34
58

ø4 9 3
.2
6.9max.
3.6min.

7 2
7 2
Ring crimping 8 1 4.5max. 5min. 10 11 1 2
terminals cannot be used. M4.2
8 1
(Top View) 34 Terminal 16.5 ø3.6min. (Top View)
3

Screw
20 7.9max.
29 21.5
2.2

28.5
30 4.5max. 6min.

SR3P-06B SR3P-05C
59 When using 42 When using
M3.5 BAA/BAP: 25.5 BAA/BAP: 33.5
8 Terminal Terminal 7
DIN Rail (BAA/BAP) Arrangement DIN Rail (BAA/BAP)
Screw
Terminal
2-ø4.2 Mounting Holes 8 7 6 5 4
Arrangement
ø5

7 6 5 2-ø4.2 Mounting Holes


(or M4 Tapped Holes) (or M4 Tapped Holes) 7 6 5
8 4
ø27

8 4
60

33
58

ø4. 34
2
M4.2
Terminal 9 10 11 1 2 3
9 3 Ring crimping 9 3
1 1
Screw 18 0 1 1 2 terminals cannot be used. 10 11 1 2
(Top View)
1

33 (Top View)
2.2

22 5max. 5min. 34 21.5


30
6.9max.
3.6min.

ø3.6min.
7.9max.

4.5max. 6min.

H-063 For
Formore
moreinformation,
information,visit
visithttp://apac.idec.com
http://eu.idec.com
S Series Relay Sockets

Relays & Sockets


Rear Wiring Sockets

Package Quantity: 1
Rated Insulation IDEC Applicable
Mounting No. of Part No.
Shape Style Color Approvals Voltage/ Relays/Timers
Style Poles (Ordering Part No.)
Rated Current (example)

250V APEM
2 Solder Terminal Black SY2S-51 UL, CSA
7A
Switches &
RY2S Pilot Lights
RY22S
Control Boxes
250V
2 PC Board Terminal Black SY2S-61 UL, CSA Emergency
7A
Stop Switches
Enabling
Switches
250V Safety Products
SY 4 Solder Terminal Black SY4S-51 UL, CSA RY4S
7A (*1)
RY42S Explosion Proof
RU4S
RU42S Terminal Blocks
250V GT5Y
4 PC Board Terminal Black SY4S-61 UL, CSA
7A (*1) Relays & Sockets

Circuit
Protectors
RY4S
250V RY42S Power Supplies
4 PC Board Terminal Black SY4S-62 UL, CSA
7A (*1) RU4S
RU42S LED Illumination

Controllers
250V
2 Solder Terminal Black SM2S-51 UL, CSA Operator
10A Interfaces
RM2S
RU2S Sensors
GT5Y-2
250V AUTO-ID
SM 2 PC Board Terminal Black SM2S-61 UL, CSA
10A

250V RM2S
2 PC Board Terminal Black SM2S-62 UL, CSA Relays
10A RU2S
Sockets

DIN Rail
250V RF1V-2A2B Products
4 PC Board Terminal Black SF1V-4-61 UL, CSA, TUV, CE
6A RF1V-3A1B

SF1V
RF1V-4A2B SJ
250V
6 PC Board Terminal Black SF1V-6-61 UL, CSA, TUV, CE RF1V-5A1B
6A
RF1V-3A3B DF

SU
*1) When using 2 poles and 4-pole sockets together, the UL rated current is 10A.
• See SF1V relay socket pages of the Product Catalog (E-189) for dimensions. S

Download
Download
catalogs
catalogs
and CAD
and CAD
fromfrom
http://eu.idec.com/downloads
http://apac.idec.com H-064
Relays & Sockets
S Series Relay Sockets

 Package Quantity: 1
Rated Insulation IDEC Applicable
Mounting No. of Part No.
Shape Style Color Approvals Voltage/ Relays/Timers
Style Poles (Ordering Part No.)
Rated Current (example)

250V
1 Solder Terminal Black SH1B-51 UL, CSA 10A
(coil terminal 7A)
RH1B
APEM
250V
Switches & 1 PC Board Terminal Black SH1B-62 UL, CSA 10A
Pilot Lights
coil terminal 7A)
Control Boxes

Emergency
Stop Switches 250V
2 Solder Terminal Black SH2B-51 UL, CSA
Enabling 10A
Switches
RH2B
Safety Products
250V
Explosion Proof 2 PC Board Terminal Black SH2B-62 UL, CSA
10A
Terminal Blocks SH
Relays & Sockets 250V
3 Solder Terminal Black SH3B-51 UL, CSA
Circuit 10A
Protectors
RH3B
Power Supplies
250V
LED Illumination 3 PC Board Terminal Black SH3B-62 UL, CSA
10A
Controllers

Operator
Interfaces 250V
4 Solder Terminal Black SH4B-51 UL, CSA
10A
Sensors
RH4B
AUTO-ID
250V
4 PC Board Terminal Black SH4B-62 UL, CSA
10A

Relays
250V RR2P
2 Solder Terminal Black SR2P-511 UL, CSA
Sockets 10A GT5P
DIN Rail
Products
SR 250V RR2P
2 Solder Terminal Black SR6P-S08 —
(8 pin) 10A GT3 (8 pin)

SJ

Rear Wiring Screw 250V RR2P


DF 2 Black SR6P-M08G —
Terminal 10A GT3 (8 pin)
SU

S
250V RR3P, RR3PA
3 Solder Terminal Black SR3P-511 UL, CSA
10A GT3 (11 pin)

SR 250V
3 Solder Terminal Black SR6P-S11 — GT3 (11 pin)
(11 pin) 10A

Rear Wiring Screw 250V RR3P, RR3PA


3 Black SR6P-M11G —
Terminal 5A GT3 (11 pin)

H-065 For
Formore
moreinformation,
information,visit
visithttp://apac.idec.com
http://eu.idec.com
S Series Relay Sockets

Relays & Sockets


Accessories
Sockets and Applicable Hold-down Springs
IDEC Applicable Relays/ Wire Spring Leaf Spring (2 pcs) Leaf Spring
Front Wiring Socket
Timers (example) SY4S-51F1 SFA-302 SFA-301 SFA-402 SFA-504
SY2S-51
SY2S-61
RY2S, RY22S   
RU4S, RU42S    APEM
SY4S-51
SY4S-61
RY4S, RY42S    Switches &
GT5Y-4  Pilot Lights
RU4S, RU42S   Control Boxes
SY4S-62
RY4S, RY42S   Emergency
RM2S    Stop Switches
SM2S-51 Enabling
SM2S-61
RU2S   
Switches
GT5Y-2 
Safety Products
RM2S  
SM2S-62
RU2S   Explosion Proof
SH1B-51
SH1B-62
RH1B    Terminal Blocks

SH2B-51 RH2B    Relays & Sockets


SH2B-62 RH2B   Circuit
SH3B-51 Protectors
SH3B-62
RH3B   
Power Supplies
SH4B-51
SH4B-62
RH4B  (2pcs)   LED Illumination

SR2P-511 (8 pin) GT3 (8 pin) Controllers


SR3P-511 (11 pin) GT3 (11 pin)

Operator
Interfaces
• For close mounting of rear mount sockets, use wire springs or SFA-302 leaf springs.
Sensors

AUTO-ID
Hold-down Springs When ordering, specify the Ordering No.

Style Shape Part No. Ordering No. Package Quantity

Relays

Wire Springs SY4S-51F1 SY4S-51F1PN10 10 Sockets

DIN Rail
Products

20
SFA-302 SFA-302PN20
(10 pairs)
SJ

DF

20 SU
SFA-301 SFA-301PN20
(10 pairs)
S

Leaf Springs

SFA-402 SFA-402PN10 10

SFA-504 SFA-504PN10 10

• Two Leaf springs are used for one relay. (One leaf spring is used for SFA-402 and SFA-504)

Download
Download
catalogs
catalogs
and CAD
and CAD
fromfrom
http://eu.idec.com/downloads
http://apac.idec.com H-066
Relays & Sockets
S Series Relay Sockets

Dimensions All dimensions in mm

(1) SY
SY2S-51 (Solder Terminal) SY2S-61 (PC Board Terminal)
Panel Thickness: Terminal Terminal 4.4 ±0.1 13.6min.
[18(n−1)+12.4] +0.5

10.4
1 to 2 Arrangement 0
Arrangement

4.1
1 4 1 4

25.6 +0.2

14.2min.∗ 16.8 ±0.1


5 8 5 8

25.4
0

9
31
25.4
9 12 9 12
31

APEM 13 14 13 14

0.3
0.3

18 3 (Bottom View) N: No. of sockets 18 3 (Bottom View)


Switches &

5.4min.∗
Pilot Lights 11 mounted 11 8-ø2 holes
18.7 15
Control Boxes
∗10.4 min. when using 1.5 (Tolerance 0.1)
Emergency 2.4 hold-down springs
12.2
Stop Switches 12.2 ∗19.2 min. when using hold-down springs
Enabling
Switches

Safety Products
SY4S-51 (Solder Terminal) SY4S-61 (PC Board Terminal)
Panel Thickness: Terminal [27(n−1)+21.4] +0.5
0 13.2 13.8min.
Explosion Proof 1 to 2 Arrangement Terminal 8.8

10.4
Arrangement 4.4

4.1
25.6 +0.2

1 2 3 4
0

Terminal Blocks 5 6 7 8 1 2 3 4
25.4
31

9 10 11 12 5 6 7 8

25.4

9
31

14.2min.∗ 16.8
13 14 9 10 11 12
Relays & Sockets 13 14
0.3

27 3 N: No. of sockets mounted


(Bottom View)
5.4min.∗

0.3
27 3 (Bottom View)
Circuit 11
11 14-ø2 holes
Protectors 18.7
15
Power Supplies ∗10.4 min. when using hold-down springs
2.4 (Tolerance 0.1)
1.5
21.2
LED Illumination 21.2
∗19.2 min. when using hold-down springs
Controllers

Operator SY4S-62 (PC Board Terminal)


Interfaces 13.2 8.2 min.∗∗
8.8
Sensors 4.4
Terminal
Arrangement
4.1

AUTO-ID
1 2 3 4
10.4

5 6 7 8
9
16.8
0.3
29

9 10 11 12
13 14

21.2 3 (Bottom View)


Relays 14-ø2 holes
12.2 min.∗

11
Sockets 15 (Tolerance 0.1)

DIN Rail
Products 1.5 ∗17.2 min. when using hold-down springs
∗∗13.2 min. when using hold-down springs

SJ (2) SM
SM2S-51 (Solder Terminal) SM2S-61 (PC Board Terminal)
DF
Panel Thickness: Terminal [27(n−1)+21.4] +0.5
0 Terminal 13.2 13.8min.
SU 1 to 2 Arrangement Arrangement
10.4
25.4
31

4.1

1 4 1 4
25.6 +0.2
0

S 5 8 5 8
9
14.2min.∗ 16.8
25.4
31

9 12
0.3

9 12 27 3
13 14 13 14
11
0.3

3 N: No. of sockets mounted


5.4min.∗

27 (Bottom View) 15 (Bottom View) 8-ø2 holes


11
18.7 1.5
∗10.4 min. when using hold-down springs (Tolerance 0.1)
21.2
2.4
∗19.2 min. when using hold-down springs
21.2

SM2S-62 (PC Board Terminal)


Terminal 13.2 8.2 min.∗∗
Arrangement
4.1

1 4
10.4

5 8
9
16.8
29

0.3

9 12
13 14
21.2 3 (Bottom View)
12.2 min.∗

8-ø2 holes
11
15 (Tolerance 0.1)

1.5 ∗17.2 min. when using hold-down springs


∗∗13.2 min. when using hold-down springs

H-067 For
Formore
moreinformation,
information,visit
visithttp://apac.idec.com
http://eu.idec.com
S Series Relay Sockets

Relays & Sockets


Dimensions
(3) SH
SH1B-51 (Solder Terminal) SH1B-62 (PC Board Terminal)
Panel Thickness: Terminal [18(n−1)+12.4] +0.5
0 3-ø2.4 holes 6.8 18min.
Terminal

6.95
1 to 2 Arrangement 4.4
Arrangement

25.4

4.7
31
1

25.6 +0.2
1

0
5
25.4

5
31

31min.∗ 11.85
0.3
9 APEM
13 14 18 3
13 14
0.3

5.95
N: No. of sockets mounted 11

5.4min.∗
18 3 (Bottom View) Switches &
15 (Bottom View) 2-ø2 holes
11 Pilot Lights
18.7 2 (Tolerance 0.1)
Control Boxes
3.5 ∗10.4 min. when using hold-down springs 1.5
2.4 12.2 ∗36 min. when using hold-down springs Emergency
12.2 Stop Switches
Enabling
Switches
SH2B-51 (Solder Terminal) SH2B-62 (PC Board Terminal) Safety Products
Panel Thickness: Terminal [27(n−1)+21.4] +0.5
0 2.85 21.5min
1 to 2 Explosion Proof
Arrangement Terminal 15.5

5.65
Arrangement 10

4.7
1 4
25.6 +0.2

Terminal Blocks
0

5 8
25.4

1 4

0.3
31

9 12 5 8

25.4

29min.* 12.5
29
13 14 9 12 Relays & Sockets
0.3

3 13 14
(Bottom View) N: No. of sockets mounted
5.4min.*

27 3

6.6
11 21.2 (Bottom View) Circuit
11 8-ø2.4 holes Protectors
18.7 15
(Tolerance 0.1) Power Supplies
*10.4 min. when using hold-down springs
3.5
*34 min. when using hold-down springs
2 LED Illumination
21.2

Controllers
SH3B-51 (Solder Terminal) SH3B-62 (PC Board Terminal) Operator
Interfaces
Panel Thickness: Terminal [36(n−1)+30.4] +0.5
0 36min.
1 to 2 Arrangement 7.35 21.3
Terminal Sensors
Arrangement 10 10
25.6 +0.2

1 2 4

4.7
0

5 6 8 AUTO-ID
25.4

1 2 4
31

9 10 12 5 6 8
25.4

6.65
31min.∗ 12.5
31

13 14 9 10 12
0.3

36 3 (Bottom View) N: No. of sockets mounted 13 14


5.4min.∗

6.6
0.3

11 36 3 (Bottom View) 8-ø2.4 holes


11
18.7
∗10.4 min. when using hold-down springs 15 (Tolerance 0.1) Relays
3.5
2 ∗36 min. when using hold-down springs
30.2 Sockets
30.2
DIN Rail
Products

SH4B-51 (Solder Terminal) SH4B-62 (PC Board Terminal)


Panel Thickness: Terminal [45(n−1)+39.4] +0.5
0 6.85 45min.
1 to 2 Arrangement 31.3
Terminal SJ
6.65

Arrangement 10 10 10
1 2 3 4
25.6 +0.2

4.7
0

5 6 7 8
25.4

1 2 3 4 DF
31

9 10 11 12
5 6 7 8
25.4

31min.∗ 12.5
31

13 14 9 10 11 12
0.3

45 3 (Bottom View) N: No. of sockets 13 14 SU


5.4min.∗

mounted
6.6
0.3

11 45 3 (Bottom View) 14-ø2.4 holes


18.7 11 S
15 (Tolerance 0.1)
∗10.4 min. when using hold-down springs
3.5
∗36 min. when using hold-down springs
39.2 2
39.2

(4) SR
SR2P-511 (Solder Terminal) SR3P-511 (Solder Terminal)
Terminal Arrangement Terminal Arrangement 2-ø3.5 Mounting Holes
Surface
Surface

2-ø3.5 Mounting Holes


Panel

4.2
Panel

4.2 (or M3 Tapped Holes) (or M3 Tapped Holes)


6
6

4 5 5 6 7
3 6 4 8
3 9
2 7
0
38

2 10
50

38
ø29

ø3
38
50

38

1 11
ø3

1 8

(Bottom View) 2.5 10 11 (Bottom View)


34 2.5 10 11 34
2.5 2.5

• See GT3 timer pages of the Product Catalog for SR6P-S08, • S ee GT3 timer pages of the Product Catalog for SR6P-S11,
SR6P-M08G dimensions. SR6P-M11G dimensions.

Download
Download
catalogs
catalogs
and CAD
and CAD
fromfrom
http://eu.idec.com/downloads
http://apac.idec.com H-068
Relays & Sockets
S Series Relay Sockets

Accessories
When ordering, specify the Ordering No.
Package
Name Shape Specifications Part No. Ordering No. Remarks
Quantity

Aluminum
DIN Rail BAA1000 BAA1000PN10 10 See H-071 for DIN rail products
Weight: Approx. 200g
APEM
BNL5 BNL5PN10 10
Switches &
Pilot Lights End Clip Zinc-plated steel
See H-071 for DIN rail products
(*1) Weight: Approx. 15g
Control Boxes
BNL6 BNL6PN10 10
Emergency
Stop Switches
Enabling
Switches DIN Rail Thickness: 5 mm
Spacer Plastic (black) SA-406B SA-406B 1 Used for adjusting spacing between
Safety Products
(*2) sockets mounted on a DIN rail
Explosion Proof

Terminal Blocks *1) When mounting the end clip (BNL5 or BNL6) on to a DIN rail, make sure that it is positioned first so that socket does not deform in shape.
*2) By using the spacer (No. SA-406B) to a DIN rail, the spacing between sockets can be adjusted in 5mm increments.
Relays & Sockets

Circuit
Protectors

Power Supplies Installation of End Clip and DIN Rail Spacer


LED Illumination DIN Rail
(BAA)

Controllers

Operator
Interfaces

Sensors

AUTO-ID

End Clip
BNL5 Spacer
SA-406B
Relays

Sockets

DIN Rail
Application Example of End Clip and DIN Rail Spacer
Products Use DIN rail spacers for adding space between adjoining sockets to prevent
miswiring and identify wiring groups.

SJ

DF

SU

S
10mm 10mm
(Two Spacers) (Two Spacers)
5mm
(One Spacer)

H-069 For
Formore
moreinformation,
information,visit
visithttp://apac.idec.com
http://eu.idec.com
S Series Relay Sockets

Relays & Sockets


Instructions
Collective Mounting of Panel Mount Sockets Soldering
The SY, SM, and SH series panel mount sockets are designed to mount When soldering, use a soldering iron of 60W (350°C), and quickly
in panel cut-outs collectively. These sockets can be mounted in the complete soldering within approximately 3 seconds. Sn-Ag-Cu is
same panel cut-out due to the standardized size. recommended for lead-free soldering. Ensure to keep the solder away
Mounting into Panel Cut-out from the socket as much as possible. Do not apply external force by
bending the terminal or pulling the wire.
To mount, insert the sockets with mounting springs facing top and APEM
bottom edges of the panel cut-out. Push the mounting spring using a Switches &
screwdriver until the mounting spring clicks into the panel. Pilot Lights

Control Boxes

Emergency
Stop Switches
Enabling
Push Panel Switches

Spring Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit
A (Total width of the sockets mounted)
Protectors
+0
L=A-5.6 – 0.5
Power Supplies

LED Illumination

Controllers

Operator
Interfaces
SY2S-51 SY4S-51 SM2S-51 SH1B-51 SY4S-51
SY4S-51 SY2S-51 SH1B-51 SH2B-51 Sensors

AUTO-ID
A
L= 18 + 27 + 27 + 18 + 27 + 18 + 18 + 27 + 27
+0
– 5.6 = 201.4 – 0.5
Relays

Socket Width Sockets


Socket Width DIN Rail
SY2S-51 18mm Products
SY4S-51
27mm
SM2S-51
SH1B-51 18mm
SJ
SH2B-51 27mm
SH3B-51 36mm DF
SH4B-51 45mm
SU

SEUEN01A_H S April 2021

Download
Download
catalogs
catalogs
and CAD
and CAD
fromfrom
http://eu.idec.com/downloads
http://apac.idec.com H-070
Ordering Terms and Conditions
Thank you for using IDEC Products.
By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read
and agree to the terms and conditions before placing your order.

1. Notes on contents of Catalogs 3. Inspections


(1) Rated values, performance values, and specification values of IDEC products We ask that you implement inspections for IDEC products you purchase without
listed in this Catalog are values acquired under respective conditions in delay, as well as thoroughly keep in mind management/maintenance regarding
independent testing, and do not guarantee values gained in combined handling of the product before and during the inspection.
conditions.
Also, durability varies depending on the usage environment and usage
4. Warranty
conditions. (1) Warranty period
(2) Reference data and reference values listed in Catalogs are for reference The warranty period for IDEC products shall be one (1) year after purchase or
purposes only, and do not guarantee that the product will always operate delivery to the specified location. However, this shall not apply in cases where
appropriately in that range. there is a different specification in the Catalogs or there is another agreement
(3) The specifications / appearance and accessories of IDEC products listed in in place between you and IDEC.
Catalogs are subject to change or termination of sales without notice, for (2) Warranty scope
improvement or other reasons. Should a failure occur in an IDEC product during the above warranty period
(4) The content of Catalogs is subject to change without notice. for reasons attributable to IDEC, then IDEC shall replace or repair that
product, free of charge, at the purchase location / delivery location of the
2. Note on applications product, or an IDEC service base. However, failures caused by the following
(1) If using IDEC products in combination with other products, confirm the reasons shall be deemed outside the scope of this warranty.
applicable laws / regulations and standards. i. The product was handled or used deviating from the conditions /
Also, confirm that IDEC products are compatible with your systems, machines, environment listed in the Catalogs
devices, and the like by using under the actual conditions. IDEC shall bear no
ii. The failure was caused by reasons other than an IDEC product
liability whatsoever regarding the compatibility with IDEC products.
iii. Modification or repair was performed by a party other than IDEC
(2) The usage examples and application examples listed in Catalogs are for
reference purposes only. Therefore, when introducing a product, confirm the iv. The failure was caused by a software program of a party other than
performance and safety of the instruments, devices, and the like before use. IDEC
Furthermore, regarding these examples, IDEC does not grant license to use v. The product was used outside of its original purpose
IDEC products to you, and IDEC offers no warranties regarding the ownership vi. Replacement of maintenance parts, installation of accessories, or the like
of intellectual property rights or non-infringement upon the intellectual was not performed properly in accordance with the user’s manual and
property rights of third parties. Catalogs
(3) When using IDEC products, be cautious when implementing the following. vii. The failure could not have been predicted with the scientific and
i. Use of IDEC products with sufficient allowance for rating and technical standards at the time when the product was shipped from
performance IDEC
ii. Safety
 design, including redundant design and malfunction prevention viii. The failure was due to other causes not attributable to IDEC (including
design that prevents other danger and damage even in the event that an cases of force majeure such as natural disasters and other disasters)
IDEC product fails Furthermore, the warranty described here refers to a warranty on the IDEC
iii. Wiring
 and installation that ensures the IDEC product used in your product as a unit, and damages induced by the failure of an IDEC product are
system, machine, device, or the like can perform and function according excluded from this warranty.
to its specifications 5. Limitation of liability
(4) Continuing to use an IDEC product even after the performance has The warranty listed in this Agreement is the full and complete warranty for IDEC
deteriorated can result in abnormal heat, smoke, fires, and the like due to products, and IDEC shall bear no liability whatsoever regarding special damages,
insulation deterioration or the like. Perform periodic maintenance for IDEC indirect damages, incidental damages, or passive damages that occurred due to an
products and the systems, machines, devices, and the like in which they are IDEC product.
used.
(5) IDEC products are developed and manufactured as general-purpose products 6. Service scope
for general industrial products. They are not intended for use in the following The prices of IDEC products do not include the cost of services, such as dispatching
applications, and in the event that you use an IDEC product for these technicians. Therefore, separate fees are required in the following cases.
applications, unless otherwise agreed upon between you and IDEC, IDEC shall (1) Instructions for installation / adjustment and accompaniment at test operation
provide no guarantees whatsoever regarding IDEC products. (including creating application software and testing operation, etc.)
i. Use  in applications that require a high degree of safety, including nuclear (2) Maintenance inspections, adjustments, and repairs
power control equipment, transportation equipment (railroads / airplanes (3) Technical instructions and technical training
/ ships / vehicles / vehicle instruments, etc.), equipment for use in outer (4) Product tests or inspections specified by you
space, elevating equipment, medical instruments, safety devices, or
any other equipment, instruments, or the like that could endanger life or The above content assumes transactions and usage within your region. Please
human health consult with an IDEC sales representative regarding transactions and usage outside
ii. Use
 in applications that require a high degree of reliability, such as of your region. Also, IDEC provides no guarantees whatsoever regarding IDEC
provision systems for gas / waterworks / electricity, etc., systems that products sold outside your region.
operate continuously for 24 hours, and settlement systems
iii. Use
 in applications where the product may be handled or used deviating
from the specifications or conditions / environment listed in the Catalogs,
such as equipment used outdoors or applications in environments
subject to chemical pollution or electromagnetic interference
If you would like to use IDEC products in the above applications, be sure
to consult with an IDEC sales representative.

Head Office
www.idec.com
6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan
USA IDEC Corporation Tel: +1-408-747-0550 opencontact@idec.com Hong Kong IDEC Izumi (H.K.) Co., Ltd. Tel: +852-2803-8989 info@hk.idec.com
Germany APEM GmbH Tel: +49-40-25 30 54-0 service@eu.idec.com China IDEC (Shanghai) Corporation Tel: +86-21-6135-1515 idec@cn.idec.com
Singapore IDEC Izumi Asia Pte. Ltd. Tel: +65-6746-1155 info@sg.idec.com Beijing Branch Tel: +86-10-6581-6131 idec@cn.idec.com
Thailand IDEC Asia (Thailand) Co., Ltd Tel: +66-2-392-9765 sales@th.idec.com Guangzhou Branch Tel: +86-20-8362-2394 idec@cn.idec.com
India IDEC Controls India Private Limited Tel: +91-80679-35328 info_india@idec.com Japan IDEC Corporation Tel: +81-6-6398-2527 jp_marketing@idec.com
Taiwan IDEC Taiwan Corporation Tel: +886-2-2577-6938 service@tw.idec.com

Specifications and other descriptions in this brochure are subject to change without notice.

You might also like