4 - 8mm O/D tube
5⁄ 32", 1⁄ 4", 5⁄ 16"
O/D tube
● Straight adaptor with shut off valve
● O/D tube to male BSP and NPTF threads
● 10 bar maximum operating pressure
● -20° to +80 Celsius operating temperature
● Connection for 4, 6, 8mm
5/32, 1/4, 5/16 diameter tube
Technical Data
Operating Medium:
Compressed Air
Max Operating Pressure:
10 bar
Ordering Information
Operating Temperature: To order, quote appropriate product number
-20°C to +80°C from the tables on the following pages.
Tube Sizes:
4, 6, 8mm O/D
5⁄ 32, 1⁄ 4, 5⁄ 16 O/D
Tube Types:
Nylon 11 or 12, polyurethane (95 shore A) and
PTFE.
Tubing should conform to
DIN 73378 metric nylon
NFE 49-100 metric PU
BS 5049 Part 4 1976 inch nylon
Materials:
Body Nickel plated brass
‘O’ Rings Buna N
Collet Nickel plated brass
Spring Cold drawn stainless steel
Plunger Brass or plastic
Thread sealant Precoat 5
Our policy is one of continuous research and development. We therefore reserve the right
06/98 to amend, without notice, the specifications given in this document. N/AL 9.11.005.01
Self Sealing Fitting
Metric tube to BSPT
C
Product A B C D G
G number O/D thread A/F
tube BSPT
101240418 4 1⁄8" 25,5 11 8,6
101240618 6 1⁄8" 27,5 11 8,6
A
B
101240628 6 1⁄4" 27,5 14 11,1
101240828 8 1⁄4" 32,7 14 11,1
D
Self Sealing Fitting
Inch tube to NPTF
C Product A B C D G
G number O/D thread A/F
tube NPTF
124240218 5⁄32" 1⁄8" 25,5 11 9,5
124240418 1⁄4" 1⁄8" 27,6 11 9,5
A
124240428 1⁄4" 1⁄4" 27,6 14 14,3
124240528 5⁄16" 1⁄4" 32,7 14 14,3
D
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can
exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not
within published specifications, consult Norgren.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to con-
sider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or dam-
age to equipment in the event of such failure.
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot
be adequately provided.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products
where applicable.
Our policy is one of continuous research and development. We therefore reserve the right
N/AL 9.11.005.02 to amend, without notice, the specifications given in this document. 06/98