R&S®RTM The R&S®RTM models with 200 MHz, 350 MHz, 500 MHz
or 1 GHz bandwidth offer a maximum sampling rate
of 5 Gsample/s and a maximum memory depth of
Digital Oscilloscope 20 Msample. As a result, they can display signals accu-
rately, right down to the details, as well as provide high
time resolution, even for long sequences.
At a glance Besides the common measurement and analysis tools,
R&S®RTM oscilloscopes have special features that help
users to achieve the desired results quickly during de-
Ease of use combined with fast and reliable results bugging and signal analysis. At the push of a button, the
is precisely what users get with the R&S®RTM QuickMeas function graphically displays the key mea-
surement values for the signal that is currently active
bench oscilloscope. While other oscilloscopes are
and updates them continuously. Functions such as mask
still booting up, the R&S®RTM is already displaying tests and video triggers are supplied as standard with the
signals that would otherwise be lost in the noise, R&S®RTM.
and evaluating results. All on one screen with two
displays, with lightning fast functions. As a true scope of the art, the R&S®RTM meets the in-
creased demands on bench oscilloscopes for the develop-
ment, production and servicing of embedded hardware,
providing time, frequency, protocol and logic analysis, plus
a digital voltmeter in a single box:
❙❙ Time analysis: high sensitivity of 1 mV/div to detect
signals that would otherwise be lost in the noise
❙❙ Frequency analysis: reliable fault detection with
integrated FFT and spectrum analysis with spectrogram
option
❙❙ Logic analysis: 20 Msample with 5 Gsample/s for detailed
analysis of digital signals
❙❙ Protocol analysis: simple triggering and decoding of
serial buses
❙❙ Digital voltmeter/frequency counter: key signal
parameters at a glance
RTM_bro_en_3606-8066-12_v0602.indd 2 15.11.2016 13:42:43
R&S®RTM Results-oriented: fast and precise
❙❙ Fast time to results: turn on, measure and done
❙❙ Signal details at the push of a button: QuickMeas
Digital Oscilloscope ❙❙ Settings in seconds: mask test
❙❙ Focus on details: search and navigation
❙❙ Integrated: FFT analysis
Benefits and ❙❙ In focus: digital voltmeter and frequency counter
▷▷ page 4
key features Accurate: down to the mV
❙❙ 1 mV/div: full measurement bandwidth
❙❙ Frontends: low noise and low crosstalk
❙❙ Deep memory: long sequences at high resolutions
❙❙ To the point: comprehensive triggering capabilities
▷▷ page 8
Usability: smart concepts
❙❙ Easy orientation: color-coded controls
❙❙ Two displays instead of one: VirtualScreen
❙❙ Error-tolerant: undo/redo function
❙❙ Remote control, data exchange: diverse interfaces
❙❙ Multilingual: choice of nine languages
Extensible: more application power
❙❙ Logic analysis: fast and precise testing of embedded
designs
❙❙ Serial protocols: easy triggering and decoding
❙❙ Segmented memory: 460 Msample with history function
❙❙ Power analysis: current and voltage in detail
❙❙ Spectrum analysis: quickly identifying interactions
between time and frequency
▷▷ page 12
Probes: excellent contacting
▷▷ page 22
Accessories: for rack installation and transport
▷▷ page 25
Models
Base unit Bandwidth Channels Max. sampling Max. acquisition memory Mixed signal option (MSO;
rate with R&S®RTM-B1 option)
analog digital
(with R&S®RTM-B1)
R&S®RTM2022 200 MHz 2 16 5 Gsample/s 20 Msample, 400 MHz,
R&S®RTM2024 200 MHz 4 460 Msample segmented 5 Gsample/s (max.),
memory (optional) 20 Msample (max.)
R&S®RTM2032 350 MHz 2
R&S®RTM2034 350 MHz 4
R&S®RTM2052 500 MHz 2
R&S®RTM2054 500 MHz 4
R&S®RTM2102 1 GHz 2
R&S®RTM2104 1 GHz 4
Rohde & Schwarz R&S®RTM Digital Oscilloscope 3
RTM_bro_en_3606-8066-12_v0602.indd 3 15.11.2016 13:42:43
Results-oriented: Fast time to results: turn on, measure and done
Optimized for fast results, the R&S®RTM starts up within
only a few seconds. The most important measurement
fast and precise results for an active signal can be obtained at the push
of a button (QuickMeas function), enabling fast signal
characterization.
R&S®RTM oscilloscopes provide a decisive edge Signal details at the push of a button: QuickMeas
when performing everyday measurement tasks, The QuickMeas function offered by the R&S®RTM oscillo-
scopes is unique. At the push of a button, it displays the
delivering more comprehensive results, faster.
key measurement values for a currently active signal (see
Measurement tools such as QuickMeas, mask test table). The signal is also graphically displayed with contin-
and math functions are supplied as standard. uously updated auxiliary lines and markers.
In addition to the QuickMeas results, the oscilloscopes
also provide customary automatic measurement functions
such as measurement of peak-to-peak voltage and signal
frequency. The results are presented in tabular form, with
statistical evaluation if desired.
QuickMeas: key results at the push of a button
Measurement Display
value
Vp+ positive peak voltage graphic display directly on
Vp– negative peak voltage the waveform
tr rise time
tf fall time
Mean mean voltage
Vpp peak-to-peak voltage tabular display on the bot-
RMS RMS value tom right of the screen
T time
f frequency
QuickMeas: automatic measurement and graphical display at the push of a button.
RTM_bro_en_3606-8066-12_v0602.indd 4 15.11.2016 13:42:44
Measurement results in detail: cursor functions Settings in seconds: mask test
The R&S®RTM offers additional functions beyond the stan- Mask tests quickly reveal whether a specific signal lies
dard horizontal and vertical cursor measurements. Users within defined tolerance limits and use statistical pass/fail
can easily apply measurements such as mean voltage, evaluation to assess the quality and stability of a device
RMS value and a pulse counter to a specific section of the under test. Signal anomalies and unexpected results are
signal. At the push of a button, the “Set to Wave” function easy to identify by stopping the measurement if the mask
automatically assigns the cursors to the corresponding is violated.
signals, eliminating the need for manual positioning.
The mask test function is a standard feature in R&S®RTM
oscilloscopes. It is easy to use and can be flexibly config-
ured. A new mask can be created from a reference signal
with just a few keystrokes. Existing masks can be loaded
from the internal memory or from a USB flash drive. If an
active mask is violated, various actions can be taken to en-
sure the optimum response.
Mask test functions
Evaluation total number of acquired waveforms
number of successful and faulty sweeps
(absolute/percentage)
total test duration
Actions acoustic signal
stop acquisition
screenshot
print
save waveform
output pulse
Mask test: mask definition from a reference signal.
Special cursor measurement: using three cursors to determine the duty cycle of a pulsed signal.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 5
RTM_bro_en_3606-8066-12_v0602.indd 5 15.11.2016 13:42:44
Focus on details: search and navigation Integrated: FFT analysis
The sampling rate of up to 5 Gsample/s enables R&S®RTM The FFT function has a dedicated button and enables us-
oscilloscopes to achieve a high time resolution. The mem- ers to detect and analyze faults within a signal's spectrum.
ory depth of up to 20 Msample makes it possible to ac- R&S®RTM oscilloscopes simultaneously provide a spectral
quire long signal sequences, e.g. 4 ms at a sampling rate display of the signal and a time domain window for check-
of 5 Gsample/s. ing the sampling interval. The Autoset button is extremely
convenient: when it is pressed, the instrument automati-
The search and navigation function helps users to man- cally selects the amplitude and frequency scaling that opti-
age even long records, enabling them to detect and mark mally matches the measured signal.
events within seconds. Users can search for simple signal
characteristics such as edge and pulse width, complex The R&S®RTM-K18 option (see page 20) turns the
bit sequences and decoded serial buses. A table lists the R&S®RTM into a spectrum analyzer with spectrogram
matching events and can be used to navigate from one function.
event to another. Separate from the search function, users
can set eight event markers on the signal and easily navi-
gate through them using the Next and Prev buttons on the
R&S®RTM oscilloscopes. For detailed analysis, the zoom
function can be used to enlarge the signal up to 200 000:1.
Search and navigation
Types edge
pulse width
peak
rise time
fall time
runt
clock data
pattern
protocol contents
Display diagram, table
Markers up to 32
Navigation marker quick-select button
rotary knob in table
FFT analysis: fast identification of harmonics at the output voltage of a
DC/DC converter.
RTM_bro_en_3606-8066-12_v0602.indd 6 15.11.2016 13:42:44
In focus: digital voltmeter and frequency counter Easy comparisons: four reference waveforms
With the R&S®RTM-K32 option, any channel can be used When analyzing faults, it is useful to compare the wave-
as a three-digit digital voltmeter (DVM) and as a seven- forms against a reference. The R&S®RTM provides up to
digit frequency counter. The measurement is performed four reference waveforms that can be generated at the
regardless of the oscilloscope status, i.e. it will update press of a button. The waveforms can be scaled, stored in-
even if the acquisition was stopped. ternally or externally and reloaded.
More than a calculator: math functions
Math functions tailored to everyday problems help solve
measurement problems quickly. For example, with just a
few keystrokes users can square the voltage waveform
and divide it by the resistance in order to directly display
power over time. In addition to basic arithmetic opera-
tions, advanced functions such as derivatives and digital
filters are available. The results can also be used as argu-
ments for other math functions.
Digital voltmeter modes
AC RMS
DC
AC + DC RMS
Crest factor
Peak+
Peak-
Peak-to-peak
Math functions
Functions +, –, *, /
max./min.
square (²), square root (√)
absolute value
pos./neg. waveform
inversion
reciprocal
log10, ln
derivation, integration
cycle, frequency
pos./neg. duty cycle
pos./neg. pulse width
Digital filters lowpass/highpass
Digital voltmeter and frequency counter.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 7
RTM_bro_en_3606-8066-12_v0602.indd 7 15.11.2016 13:42:45
Accurate: down to 1 mV/div: full measurement bandwidth
With their input sensitivity of up to 1 mV/div, R&S®RTM
oscilloscopes offer high vertical resolution. Other oscillo-
the mV scopes attain such high input sensitivity only by employ-
ing software-based zooming or by limiting the bandwidth.
The R&S®RTM shows a signal's real sampling points over
the full measurement bandwidth, even at 1 mV/div. This
Rohde & Schwarz has many years of experience high measurement accuracy is particularly beneficial when
developing precision test and measurement measuring small signal amplitudes.
equipment and has brought this expertise to bear in
Frontends: low noise and low crosstalk
the R&S®RTM oscilloscopes. Users benefit from top The accuracy of a signal displayed on the screen greatly
accuracy and excellent analysis capabilities thanks depends on the oscilloscope's inherent noise. R&S®RTM
to deep memory and a powerful trigger system. oscilloscopes have low-noise frontends and A/D convert-
ers, enabling them to measure precisely, even at the small-
est vertical resolutions.
This precision is retained even when additional channels
are used. The R&S®RTM has an excellent channel-to-
channel isolation of > 50 dB up to 500 MHz, which en-
sures that the signal from one channel has the lowest pos-
sible influence on signals from the other channels.
Acquisition period as a function of sampling rate and memory depth
10 ksample 1 Msample 10 Msample 20 Msample
5 Gsample/s 2 μs 200 μs 2000 μs 4000 μs
2.5 Gsample/s 4 μs 400 μs 4000 μs 8000 μs
RMS: 82.46 µV Vpp: 560.00 µV
Extremely low inherent noise, even for a vertical input sensitivity of 1 mV/div at full bandwidth and
full resolution.
RTM_bro_en_3606-8066-12_v0602.indd 8 15.11.2016 13:42:45
Deep memory: long sequences at high resolutions
The more details an oscilloscope can show, the higher the
probability of detecting signal faults and important events.
The oscilloscope must have a high time resolution, i.e. a
high sampling rate. In addition, many applications require
long acquisition periods, for instance for analyzing tran-
sients or serial protocols. This is where R&S®RTM oscillo-
scopes excel. They offer a deep memory of 20 Msample
at a time resolution of up to 200 ps (5 Gsample/s sampling
rate). When combined with the R&S®RTM-K15 history and
Trigger types segmented memory option, the memory is expanded to
Edge rising, falling, both
460 Msample.
LF, RF suppression, lowpass
hysteresis: automatic, small, medium, large
To the point: comprehensive triggering capabilities
Pulse time: >, <, =, ≠
Precise triggering ensures a stable signal display on the
interval: inside, outside
screen and fast isolation of signal events of interest.
polarity: positive, negative
R&S®RTM oscilloscopes offer many standard trigger ca-
Rise time polarity: rising, falling, both
pabilities, including pulse width, runt and video triggers.
level: upper, lower
Capabilities include complex trigger conditions with logical
time: >, <, =, ≠
linking of analog and digital channels. Serial protocol trig-
Runt level: upper, lower
gers are optionally available.
polarity: positive, negative
Video PAL, PAL-M, NTSC, SECAM, SDTV 576i,
Dedicated buttons allow fast switching between the Auto
HDTV 720p, HDTV 1080p, HDTV 1080i
and Normal triggers as well as selection of the trigger
signal: positive, negative
edge and source. The rotary knob for trigger level offers
lines
additional operating convenience: a single press sets the
frames: odd, even, all
trigger level to 50 % of the signal amplitude.
Logic pattern over analog and digital channels
duration: >, <, =, ≠
interval: inside, outside, timeout
Protocol (optional) content
error
B trigger edge
Complex sequences are found quickly using the pattern trigger.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 9
RTM_bro_en_3606-8066-12_v0602.indd 9 15.11.2016 13:42:45
Overview of the R&S®RTM oscilloscope
Control elements
LAN interface for remote control or for accessing the instrument via a web browser Extensive cursor-based All instruments
comes as standard. A GPIB interface is available as an option. measurement functions can be e xtended
The DVI output controls a monitor or a data projector. to 1 GHz
Preset to return to default
Brilliant 8.4" XGA color
display
One-touch documentation:
easily save screenshots and
measurements
Help: context-sensitive and
always available
Knob for setting the
intensity of the waveforms
❙❙ Menus with flat structure
for fast access
❙❙ Fluent in different
languages such as
German, English, French,
Spanish, Russian,
simplified and traditional
Chinese, Korean and
Japanese
Quickly ready for use
thanks to fast booting
10
RTM_bro_en_3606-8066-12_v0602.indd 10 15.11.2016 13:42:46
Key measurement results Multilevel undo/redo function Fast access to logic and
at the push of a button to easily restore previous protocol analysis
settings
Direct access to frequently
required analysis functions
Easy search and navigation
between signal events
❙❙ USB port for data ex-
change, documentation
or firmware updates
❙❙ Additional device and
USB host ports on the
rear side
Color-coded controls
indicate the currently
selected channel
❙❙ Scrollable screen content History function for analysis ❙❙ Probe interface supports all Rohde & Schwarz probes
❙❙ VirtualScreen extends screen of 460 Msample deep ❙❙ Digital voltmeter and frequency counter can be activated
to 20 divisions for straightfor- segmented memory on every channel
ward display of all signals ❙❙ Spectrum analysis and spectrogram on every channel
Rohde & Schwarz R&S®RTM Digital Oscilloscope 11
RTM_bro_en_3606-8066-12_v0602.indd 11 15.11.2016 13:42:47
Extensible: more Adaptable: software options on demand
The base unit includes the complete functionality of an
advanced oscilloscope but is extensible in steps. For ex-
application power ample, analysis options are available for serial buses and
power electronics. The R&S®RTM keeps pace with the
challenges that are sure to arise in any company.
Investments in test and measurement equipment Simple and free of charge: firmware updates
are subject to one all-important rule: the equipment The instrument firmware is updated using a USB storage
device. Free updates can be downloaded from the Internet
must be capable of growing with user requirements.
at www.rohde-schwarz.com.
Rohde & Schwarz has optimized the R&S®RTM to
meet this demand. Higher bandwidth: upgrade including calibration
All R&S®RTM oscilloscope models can be upgraded to
Availability without interruption: adaptable higher bandwidths as needed. The upgrade option in-
hardware cludes complete testing and calibration of the instrument
With R&S®RTM oscilloscopes, there is no need to return by Rohde & Schwarz at one of its service centers.
instruments for upgrades. Hardware options can be en-
abled with a keycode (e.g. logic analysis) or simply in- Secure erase
stalled on site (e.g. GPIB interface), yielding the following The secure erase function protects sensitive data. This
benefits: central function removes all user data and settings, includ-
❙❙ Quick and easy installation of new options ing device setups and reference waveforms.
❙❙ Instrument immediately ready for continued use
❙❙ No additional installation costs
❙❙ No additional expense for alignment or recalibration after
installation of options
Options
Bandwidth upgrade 200 MHz to 350 MHz R&S®RTM-B201
200 MHz to 500 MHz R&S®RTM-B202
200 MHz to 1 GHz R&S®RTM-B203
350 MHz to 500 MHz R&S®RTM-B200
350 MHz to 1 GHz R&S®RTM-B204
500 MHz to 1 GHz R&S®RTM-B205
Logic analysis (MSO) R&S®RTM-B1
GPIB Interface R&S®RTM-B10
Serial triggering and I²C/SPI R&S®RTM-K1
decoding
UART/RS-232/RS-422/ R&S®RTM-K2
RS-485
CAN/LIN R&S®RTM-K3
I²S/LJ/RJ/TDM R&S®RTM-K5
MIL-STD-1553 R&S®RTM-K6
ARINC 429 R&S®RTM-K7
History and segmented R&S®RTM-K15
memory
Spectrum analysis and R&S®RTM-K18
spectrogram
Power analysis R&S®RTM-K31
R&S®RTM oscilloscopes: prepared for logic analysis. Installation is a sim-
Digital voltmeter (DVM) R&S®RTM-K32
ple on-site process without shipping back the instrument.
12
RTM_bro_en_3606-8066-12_v0602.indd 12 15.11.2016 13:42:49
Logic analysis: fast Precision measurement: up to 5 Gsample/s
sampling rate
The R&S®RTM oscilloscopes' sampling rate of up to
and precise testing 5 Gsample/s makes it possible to accurately measure the
timing of logic signals. Since the signals can be precisely
time-referenced to one another, timing and clock errors
of embedded can be detected with greater ease, e.g. on serial or parallel
bus signals. R&S®RTM oscilloscopes use the high sam-
pling rate over the entire acquisition time, ensuring high
designs time resolution even for long acquisition periods.
Deep memory: acquire long signal sequences
Logic signals are stored in the R&S®RTM with up to
The R&S®RTM-B1 option turns the R&S®RTM into an 20 Msample, or even up to 460 Msample when combined
easy-to-use mixed signal oscilloscope (MSO) with 16 with the R&S®RTM-K15 option. This long acquisition peri-
ods in combination with the high sampling rate makes it
digital channels.
easy to detect timing errors even far from the trigger point.
The different memory depths for the digital and analog
channels eliminate the need to restrict the acquisition peri-
ods for digital channels.
Better overview: VirtualScreen
Superimposed displays of logic and analog signals
Logic analysis features are hard to read and make analysis more difficult. The
Channels 16 divided over two logic probes
VirtualScreen of the R&S®RTM oscilloscopes uses a differ-
Acquisition memory 10 Msample with two logic probes;
ent approach. It doubles the usable screen area for clear
20 Msample with one logic probe
display of the channels with no overlapping. Math, refer-
Sampling rate 2.5 Gsample/s with two logic probes;
ence and logic signals can be displayed above or below
5 Gsample with one logic probe
the analog channels.
Input impedance 100 kΩ ± 2 % || ≈ 4 pF (meas.) at the probe
tip
Everything at a glance: activity display
Max. input frequency 400 MHz (meas.)
The R&S®RTM oscilloscopes' activity display provides a
Max. input voltage ±40 V (Vp)
clear overview of the current status of all logic channels
Min. input signal 500 mV (Vpp) (meas.)
(high, low, toggle), regardless of the trigger settings. Users
deviation
can see the status of all logic signals at a glance.
Activity display: status information for the digi-
tal signals independent of acquisition and instru-
ment settings.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 13
RTM_bro_en_3606-8066-12_v0602.indd 13 15.11.2016 13:42:50
Serial protocols: Tools for protocol analysis: triggering and
decoding options
Serial bus signals include control, address and clock infor-
easy triggering and mation in addition to the user data. Consequently, addi-
tional software support is typically required for debugging
systems that use serial data buses. Isolating protocol-
decoding specific events becomes easier if the oscilloscope can trig-
ger on the content of the serial protocol that is being used
and display the decoded message.
❙❙ Hardware-implemented decoding for finding errors The R&S®RTM provides versatile tools for protocol-specific
fast triggering and decoding of serial interfaces. Extensive
❙❙ Direct triggering on protocol contents and error trigger capabilities help acquire relevant events. Because
states decoding is hardware-implemented, the R&S®RTM enables
❙❙ Simultaneous decoding and display of up to four smooth operation while quickly isolating faults.
protocols
❙❙ Deep memory of up to 460 Msample
(R&S®RTM-K15)
❙❙ Display as a color-coded message or in table format
(ASCII, binary, octal, decimal, hexadecimal)
❙❙ Powerful search and navigation over the entire
memory
❙❙ Easy configuration using adaptive wizards
Decoded hexadecimal I2C message.
14
RTM_bro_en_3606-8066-12_v0602.indd 14 15.11.2016 13:42:50
Everything at a glance: clear display Intuitive: search and navigation
Decoded protocols can be displayed in all conventional The different tools for protocol analysis are tightly inte-
formats, including hex and ASCII. The different sections of grated. The search function can be used to quickly find
the message (address, data, start, etc.) are color-coded to protocol-specific content segments, making navigation be-
make analysis easier. Label lists can be loaded to simplify tween segments possible. For example, when a row in the
and speed up interpretation. IDs and addresses in the data decoding table is selected, the corresponding data is also
stream are designated with easily understood aliases such highlighted on the displayed waveform.
as “Engine Speed” instead of in hex format. A tabular list-
ing of the decoded data is provided in addition to the usual Multiple protocols in parallel: not a problem
honeycomb diagram. Errors often result from the interaction of multiple influenc-
ing factors. The R&S®RTM decodes and displays up to four
Complete communications instead of snippets: buses in parallel, making it possible to immediately identify
deep memory unwanted interactions. The R&S®RTM VirtualScreen pro-
The deep memory of the R&S®RTM makes it possible to vides a clear overview at all times.
acquire meaningful communications segments and helps
users quickly understand the DUT behavior in context. The
detailed display of the decoding is adjusted automatically
depending on the zoom factor. The decoded data can also
be displayed in tabular form, keeping everything clear.
Options for triggering and decoding
Application Serial standard Option
Embedded I2C/SPI R&S®RTM-K1
UART/RS-232/RS-422/RS-485 R&S®RTM-K2
Automotive CAN/LIN R&S®RTM-K3
Audio I S/LJ/RJ/TDM
2
R&S®RTM-K5
Aerospace and defense MIL-STD-1553 R&S®RTM-K6
ARINC 429 R&S®RTM-K7
Communicative popup windows: intuitive display of setting
options for error states in the MIL-STD-1553 protocol.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 15
RTM_bro_en_3606-8066-12_v0602.indd 15 15.11.2016 13:42:50
Segmented Long acquisition periods with 460 Msample
memory
The deep, segmented memory provided by the
memory: R&S®RTM-K15 option can be used for analyzing signal se-
quences over a long observation period with no signal-free
gaps. For example, protocol-based signals such as I2C or
460 Msample with SPI in embedded designs can be acquired over several
seconds or minutes. Thanks to the variable segment size
from 10 ksample to 20 Msample, the 460 Msample mem-
history function ory is optimally utilized; up to 45 000 cohesive individual
recordings are possible.
This feature will be appreciated by physics researchers
❙❙ 460 Msample segmented acquisition memory who are monitoring pulsed lasers as well as developers of
❙❙ Acquisition of up to 45 000 individual segments pulsed radar systems. When combined with the mixed sig-
❙❙ Short blind time: < 5 µs nal option or serial bus analysis options, the R&S®RTM-K15
❙❙ Acquisition of both analog and digital signals as option is ideal for debugging embedded designs.
well as serial bus protocols in the segmented
memory
❙❙ Access to all analysis tools (e.g. mask test or
QuickMeas)
❙❙ Exact timestamp for all acquisitions
Easy selection of segment length.
16
RTM_bro_en_3606-8066-12_v0602.indd 16 15.11.2016 13:42:50
Apply all oscilloscope functions to past events No detail missed thanks to minimum blind time
By pressing the History key, all previous acquisitions up to In the ultra-segmented mode, the minimum blind time is
the maximum segmented memory depth of 460 Msample less than 5 µs. Serial protocol and pulse sequences can be
are available for further analysis. recorded practically without interruptions. In history mode,
users can easily navigate – either manually or automatical-
All analysis tools are available in history mode, including ly – through all recorded segments, and reconstruct the
mask test, QuickMeas function and FFT analysis. The his- history thanks to very exact timestamps.
tory function can also be used with the digital channels of
the MSO option, and be combined with all serial bus anal-
ysis options as well as the R&S®RTM-K18 spectrum analy-
sis and spectrogram option.
A segmented memory of 460 Msample makes it possible to record and analyze burst signals with up
to 45 000 segments.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 17
RTM_bro_en_3606-8066-12_v0602.indd 17 15.11.2016 13:42:51
Power analysis: Specialized measurement functions for
characterizing power electronics
Analysis tools support verification and debugging during
current and voltage the development of current and voltage supply circuits.
The R&S®RTM-K31 power analysis option facilitates the
analysis of the turn on/turn off behavior, the internal trans-
in detail fer function of the overall circuit, the safe operating area
(SOA), the output signal quality and any loss.
Measurement functions of the R&S®RTM-K31 option
❙❙ Analysis of input and output as well as the transfer Measurement Measurement functions
function of switched-mode power supplies Input current harmonics EN 61000-3-2
❙❙ Measurement wizard for fast results class A, B, C, D
❙❙ Simple and fast documentation MIL-STD-1399
❙❙ Analysis of harmonic current in line with RTCA DO-160
conventional EN, MIL and RTCA standards inrush current
power quality
power consumption
Power converter modulation analysis
control
slew rate
dynamic on-resistance
Power path safe operating area (SOA mask editor)
turn on/turn off
switching loss
power efficiency
Output output ripple
transient response
output spectrum
The online help facilitates quick and easy testing.
18
RTM_bro_en_3606-8066-12_v0602.indd 18 15.11.2016 13:42:51
Graphical support for error-free operation Easy, clear documentation of power analysis
When users select a measurement function, graphics Each result can be added to the test report simply by
guide them through the test setup. Detailed illustrations pressing a button. The test report documents the current
show the correct contacting of probes and current probes. setup and configuration. The R&S®Oscilloscope Report
The oscilloscope configures itself automatically based on Creator – available free of charge on the Rohde & Schwarz
the selected measurement function and delivers quick website – is used to generate a report. Users can define
results. For a detailed analysis or for documentation pur- the level of detail for the report and customize the layout,
poses, the measurement results are available in .csv file for example, by adding a company logo. The output for-
format. mat is .pdf.
Standards for limiting the harmonic current Extensive accessories for contacting and delay
Depending on the application, different standards for lim- compensation
iting the harmonic current must be met when developing A wide range of passive and active probes permits mea-
switched-mode power supplies. The R&S®RTM-K31 option surements in common voltage and current ranges. The
supports the user during testing of all conventional stan- R&S®RT-ZF20 deskew fixture for power measurements
dards: EN 61000-3-2 classes A, B, C, D, MIL-STD-1399 and can be used to time-synchronize the measurement signals
RTCA DO-160. from the current and voltage probes. The R&S®RTM-K31
power analysis option automatically deskews the current
probe and voltage probe signals at the push of a button.
Extensive result documentation.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 19
RTM_bro_en_3606-8066-12_v0602.indd 19 15.11.2016 13:42:51
Spectrum analysis: Fast and independent: separate signal paths for
time and frequency
Difficult-to-find faults often result from the interaction
quickly identifying between time and frequency signals. The R&S®RTM-K18
spectrum analysis and spectrogram option makes it easy
to find such errors quickly. The analysis range is from DC
interactions to the instrument bandwidth (max. 1 GHz). Implementa-
tion in separate signal paths allows independent setting of
time and frequency parameters. Like a spectrum analyzer,
between time and parameters such as center frequency and resolution band-
width can be adapted to the specific measurement task
at hand and the optimum time domain settings can be se-
frequency lected. The hardware-implemented digital downconverter
(DDC) reduces the spectrum to the components relevant
for analysis, ensuring optimum performance and the fast-
est multi-domain analysis in this oscilloscope class.
❙❙ From DC to the instrument bandwidth
❙❙ Independent, simultaneous time and frequency Parallel operation: correlation between frequency
analysis and time
❙❙ High sensitivity and wide dynamic range for reliable Advanced electronics is based on the seamless interaction
detection of interference between protocol-based interfaces, digital, analog and
❙❙ Development over time in spectrogram frequency components. Simultaneous analysis of all com-
❙❙ Can be combined with history function and ponents, for example with the R&S®RTM-K18 option, is a
460 Msample segmented memory must. The broadband spectrum is obtained from a single
❙❙ Automatic and manual peak markers recording using fast Fourier transformation (FFT). Time,
❙❙ Trace types: normal, mean value, max. hold and frequency and protocol information originates from the
min. hold same recording, and time references can be quickly rec-
ognized. Measurement windows help users select specific
areas of the recording, simplifying the acquisition of fre-
quency switching operations, for example.
Two-path architecture for independent, simultaneous setting of time and spectrum analysis
parameters
Selected
channel
Spectrum analysis path
Digital downconverter
MUX
(DDC)
Memory
Time
signal
Channels decimation
1 to 4 trigger
Time signal path
20
RTM_bro_en_3606-8066-12_v0602.indd 20 15.11.2016 13:42:51
Spectrogram: display of frequency over time
A spectrogram displays the frequency over time in ad-
dition to the current spectrum. The magnitude can be
color-coded for easy interpretation. Thanks to the high
FFT rate, even fast frequency changes can be displayed.
Together with the R&S®RTM-K15 history and segmented
memory option, the spectrogram marker shows the time
of the acquisition and makes it possible to load the corre-
sponding time and frequency waveforms onto the screen.
All R&S®RTM tools are available for analyzing the loaded
waveforms.
Markers: down to the μs
Markers can be automatically positioned on the frequency
peaks for fast analysis. An adaptable threshold defines the
peaks. Parameters such as excursion and maximum peak
width can be adjusted for in-depth analysis. Results can be
compiled in a table (absolute or relative to a specific refer-
ence marker). Selectable delta measurements make it easy
to adjust the distances between signal peaks.
Test signal from three different perspectives: time domain (top), spectrogram (center) and frequency
domain (bottom).
Rohde & Schwarz R&S®RTM Digital Oscilloscope 21
RTM_bro_en_3606-8066-12_v0602.indd 21 15.11.2016 13:42:52
Probes: excellent The R&S®RTM probe family
Passive probes are suited for general measurements on
low-frequency signals with less stringent accuracy require-
contacting ments. The R&S®RTM comes with one R&S®RTM‑ZP10
passive probe (500 MHz bandwidth) per oscilloscope
channel. The R&S®RT‑ZH10/-ZH11 passive high-voltage
probes are used for voltages over 400 V.
High-quality active and passive probes complete the
R&S®RTM oscilloscopes. They measure with high Active probes are used whenever the load on the device
under test must be low, or when the measurement signal
accuracy, are reliable and easy to use.
contains high-frequency components that must not be
distorted. Even signals in the kilohertz range can contain
high-frequency components of well over 100 MHz on their
edges. For these applications, Rohde & Schwarz has a fam-
ily of high-quality active probes. Due to their bandwidth,
the R&S®RT-ZS10E and R&S®RT-ZS10 single-ended probes
are suitable for R&S®RTM oscilloscopes. The two differ
only in the functions they provide. The R&S®RT-ZS10E of-
fers solid basic functionality and an attractive price/perfor-
mance ratio, while the R&S®RT-ZS10 has more extensive
accessories as well as some useful extras such as an inte-
grated voltmeter and a micro button on the probe tip for
instrument control.
The R&S®RT-ZD10 und R&S®RT-ZD20 probes are ideal for
differential measurements; they also integrate a voltme-
ter and a micro button for instrument control. For differ-
ential high-voltage measurements (up to 100 MHz), the
R&S®RT-ZD01 probe is the best choice.
Two current probes with external power supply, the
R&S®RT-ZC10 up to 150 A (RMS) and the R&S®RT-ZC20 up
to 30 A (RMS) as well as the R&S®RT-ZC20B current probe
that receives power directly from the oscilloscope are
available for current measurements.
High signal fidelity due to excellent specifications
Besides bandwidth, the crucial parameters for probes are
input impedance and dynamic range. With their high in-
put impedance, the active probes put only a minimal load
on a signal source. The very large vertical dynamic range
prevents signal distortion, especially at high frequencies.
Measurements are not interrupted for compensation pro-
cesses because the probes' offset and gain errors are near-
ly independent of temperature (e.g. zero drift < 90 μV/°C
for the R&S®RT-ZS10/-Z10E probes).
▷▷ For more information, see the product brochure:
Digital oscilloscopes from Rohde & Schwarz, Probes and
accessories (PD 3606.8866.12).
Practical design: micro button for convenient instrument control. Diverse
probe tips and ground cables are included as standard accessories.
22
RTM_bro_en_3606-8066-12_v0602.indd 22 15.11.2016 13:42:52
Micro button for convenient instrument control R&S®ProbeMeter: integrated voltmeter for precise
The situation is all too familiar. The user has carefully po- DC measurements
sitioned the probes on the device under test and now Is the supply voltage correct? Is DC voltage superim-
wants to start the measurements – but does not have a posed? These questions from everyday practice are
hand free. The micro button on the active probes from answered by the active probes' integrated voltmeter
Rohde & Schwarz eliminates this problem. The micro but- (R&S®ProbeMeter). It always shows the DC value of a
ton is situated on the probe tip, and different functions measurement signal with the full dynamic range – regard-
such as Run/Stop, Autoset or Adjust Offset can be as- less of the other instrument settings. The following advan-
signed to this button. tages simplify everyday measurement tasks:
❙ Fast verification of supply voltages and signal levels
without changing the oscilloscope settings
❙ Automatic compensation of the DC component for AC
measurements with optimal dynamic range
❙ DC value of a measurement signal as a reference for
Menu for configuring trigger level setting
the micro button. ❙ Significantly higher DC measurement accuracy
compared to a traditional oscilloscope channel
❙ DC common mode and differential voltage on the
R&S®RT-ZD10
R&S®ProbeMeter: high DC measurement accuracy regardless of instru-
ment settings.
Selection of probes
R&S®RT-ZC20B current probe (100 MHz, 30 A (RMS)). R&S®RT-ZD01 high-voltage differential probe (100 MHz, 1 kV (RMS)).
R&S®RT-ZS10.
Rohde & Schwarz active probes. R&S®RT-ZD10/20.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 23
RTM_bro_en_3606-8066-12_v0602.indd 23 15.11.2016 13:42:55
Probe Bandwidth Attenuation Input Input Dynamic range Extras
factor impedance capacitance
Passive probes
R&S®RTM-ZP10 500 MHz 10:1 10 MΩ ≈ 10 pF 400 V (RMS)
Active broadband probes
Single-ended
R&S®RT-ZS10E 1.0 GHz 10:1 1 MΩ 0.8 pF ±8 V
R&S®RT-ZS10 1.0 GHz 10:1 1 MΩ 0.8 pF ±8 V 1)
R&S®RT-ZS20 1.5 GHz 10:1 1 MΩ 0.8 pF ±8 V 1)
Differential
R&S®RT-ZD10 1.0 GHz 10:1/100:1 1 MΩ 0.6 pF/1.3 pF ±5 V/60 V DC, 1)
42.4 V AC (peak)
R&S®RT-ZD20 1.5 GHz 10:1 1 MΩ 0.6 pF ±5 V 1)
High-voltage probes
Single-ended
R&S®RT-ZH10 400 MHz 100:1 50 MΩ 7.5 pF 1 kV (RMS)
R&S®RT-ZH11 400 MHz 1000:1 50 MΩ 7.5 pF 1 kV (RMS)
Differential
R&S®RT-ZD01 100 MHz 100:1/1000:1 8 MΩ 3.5 pF ±140 V/±1400 V
1)
R&S®ProbeMeter and micro button for instrument control.
Probe Bandwidth Max. current Rise time Sensitivity error Max. input Extras
(RMS/peak) voltage
Current probes
R&S®RT-ZC05B 2 MHz 500 A/±700 A 175 ns ±1 % up to 500 A (RMS) 600 V (CAT II), 2)
300 V (CAT III)
R&S®RT-ZC10 10 MHz 150 A/±300 A 35 ns ±1 % up to 150 A (RMS) 600 V (CAT II), 3)
R&S®RT-ZC10B 300 V (CAT III) 2)
R&S®RT-ZC20 100 MHz 30 A/±50 A 3.5 ns ±1 % up to 30 A (RMS) 300 V (CAT I) 3)
R&S®RT-ZC20B 100 MHz 30 A/±50 A 3.5 ns ±1 % up to 30 A (RMS) 300 V (CAT I) 2)
EMC near-field probes
R&S®HZ-14 9 kHz to 1 GHz – – – – 4)
R&S®HZ-15 30 MHz to 3 GHz – – – – 5)
2)
Rohde & Schwarz probe interface for probe detection and power supply.
3)
External power supply r equired, e.g. R&S®RT-ZA13.
4)
Passive and active E and H near-field probe for EMC debugging.
5)
E and H near-field probe for EMC debugging, 20 dB gain with R&S®HZ-16.
24
RTM_bro_en_3606-8066-12_v0602.indd 24 15.11.2016 13:42:55
Accessories: for Safely stowed away
Thanks to an extensive selection of storage and transpor-
tation accessories, the R&S®RTM is always fully protected
rack installation and and easy to transport. The R&S®RTM-Z3 soft carrying bag
provides ample space for the oscilloscope, probes and
cables.
transport Easy integration
The R&S®ZZA-RTM rackmount kit permits easy installation
in only four height units, e.g. for testing directly on the
production line.
Accessories
Front cover R&S®RTM-Z1
Soft carrying bag R&S®RTM-Z3
Transit case R&S®RTM-Z4
Rackmount kit R&S®ZZA-RTM
Rohde & Schwarz R&S®RTM Digital Oscilloscope 25
RTM_bro_en_3606-8066-12_v0602.indd 25 15.11.2016 13:42:58
Universal: numerous Electronics development
Oscilloscopes are used for a variety of tasks in the devel-
opment of embedded designs, ranging from putting hard-
functions for many ware into operation to QM acceptance testing, certification
and servicing. All these tasks require an oscilloscope with
intelligent measurement functions that can deliver precise
applications results based on intuitive operation. The R&S®RTM oscillo-
scopes were developed to perform these tasks and fulfill
the related requirements. For example, the QuickMeas
function yields first results only a few seconds after pow-
A bench oscilloscope should be fast and easy to er-on. Logic and protocol analysis enable more in-depth
use and deliver reliable results. It should handle signal analysis for debugging embedded designs.
diverse applications from time analysis to FFT, from
Production
logic analysis to protocol analysis. This is where the Quality testing of electrical signals should be based on a
R&S®RTM excels. tolerance test with pass/fail results. The mask test is the
tool of choice for this application. The tester only needs to
connect the device under test to the oscilloscope and re-
cord the measurement result. Since the mask test is inte-
grated into the R&S®RTM, no additional costs are incurred.
Education
To successfully teach students the theoretical and practical
aspects of working with oscilloscopes, an ease-of-use con-
cept combined with state-of-the-art technology is highly
beneficial. The R&S®RTM oscilloscopes are perfect for ev-
eryday use at universities and colleges due to the diverse
manual settings and rugged design. The password-pro-
tected education mode can be used to disable automatic
functions such as Autoset. Data and programming in-
terfaces are already included, for instance for seamless
MATLAB® integration. In addition, a complete portfolio of
software and hardware options and probes is available for
measuring signals in research labs.
Service
Service technicians must rapidly identify faulty modules.
The R&S®RTM oscilloscopes support them with compre-
hensive measurement functions and straightforward oper-
ation. Their lightweight, compact design facilitates work at
customer sites, for instance in a switching cabinet.
R&S®RTM oscilloscopes: suitable for all tests and measurements.
26
RTM_bro_en_3606-8066-12_v0602.indd 26 15.11.2016 13:42:59
Specifications in brief
Specifications in brief
Vertical system
Number of channels R&S®RTM2022/2032/2052/2102 2
R&S®RTM2024/2034/2054/2104 4
Bandwidth (–3 dB) at 50 Ω R&S®RTM2022/2024, R&S®RTM2032/2034, 200 MHz, 350 MHz, 500 MHz, 1 GHz
R&S®RTM2052/2054, R&S®RTM2102/2104
Rise time (calculated) R&S®RTM2032/2034, R&S®RTM2022/2024, 1 ns, 1,75 ns, 700 ps, 350 ps
R&S®RTM2052/2054, R&S®RTM2102/2104
Input impedance 50 Ω ± 1.5 %, 1 MΩ ± 1 %
input sensitivity max. bandwidth in all ranges 50 Ω: 1 mV/div to 2 V/div,
1 MΩ: 1 mV/div to 10 V/div
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5 °C after self-alignment
input sensitivity > 5 mV/div ±1.5 %
input sensitivity ≤ 5 mV/div ±2 %
Resolution 8 bit, up to 16 bit with high resolution decimation
Acquisition system
Maximum realtime sampling rate 2.5 Gsample/s; 5 Gsample/s, interleaved
Acquisition memory 10 Msample; 20 Msample, interleaved;
with R&S®RTM-K15 option: 460 Msample segment-
ed memory
Decimation algorithms combination of decimation mode and waveform sample, peak detect, high resolution
arithmetics possible
Waveform arithmetics off, envelope, average, smooth, filter
Horizontal system
Timebase range R&S®RTM202x/RTM203x/RTM205x selectable between 1 ns/div and 500 s/div
R&S®RTM210x selectable between 0.5 ns/div and 500 s/div
Timebase accuracy ±3.5 ppm
Channel deskew ±100 ns
Trigger system
Trigger types edge, width, video (PAL, SECAM, PAL-M, SDTV,
HDTV), pattern, runt, slew rate, B trigger;
optional: I2C, SPI, UART/RS-232/RS-422/RS-485,
CAN/LIN, MIL-STD-1553, ARINC 429
Trigger level ±10 div from center of screen
Analysis and measurement functions
QuickMeas at the push of a button, internal measurement peak-to-peak voltage, pos. peak, neg. peak, rise
values are written directly onto the waveform and time, fall time, mean value, RMS value, time,
updated continuously frequency
Automated measurements 31 measurement functions
Cursor measurements 14 measurement functions
Waveform mathematics 20 measurement functions
MSO option
Digital channels 16 (2 logic probes)
Input impedance 100 kΩ || 4 pF
Sampling rate 2 logic probes connected, 2.5 Gsample/s per channel,
1 logic probe connected 5 Gsample/s per channel
Acquisition memory 2 logic probes connected, 10 Msample per channel,
1 logic probe connected 20 Msample per channel
General data
Dimensions W×H×D 403 mm × 189 mm × 142 mm
(15.87 in × 7.44 in × 5.59 in)
Weight 4.1 kg (9.04 lb)
Screen 8.4" XGA TFT color display (1024 × 768 pixel)
Interfaces 2 × USB host, USB device, LAN, GPIB (optional),
DVI-D for external monitor
For data sheet, see PD 3606.8066.22 and www.rohde-schwarz.com.
Rohde & Schwarz R&S®RTM Digital Oscilloscope 27
RTM_bro_en_3606-8066-12_v0602.indd 27 15.11.2016 13:42:59
Ordering information
Designation Type Order No
Base unit (including standard accessories: per channel: 500 MHz passive probe (10:1), compact manual, CD-ROM (with operating and service manual),
power cord)
Digital Oscilloscope
Digital Oscilloscope, 200 MHz, 2 channels R&S®RTM2022 5710.0999.22
Digital Oscilloscope, 200 MHz, 4 channels R&S®RTM2024 5710.0999.24
Digital Oscilloscope, 350 MHz, 2 channels R&S®RTM2032 5710.0999.32
Digital Oscilloscope, 350 MHz, 4 channels R&S®RTM2034 5710.0999.34
Digital Oscilloscope, 500 MHz, 2 channels R&S®RTM2052 5710.0999.52
Digital Oscilloscope, 500 MHz, 4 channels R&S®RTM2054 5710.0999.54
Digital Oscilloscope, 1 GHz, 2 channels R&S®RTM2102 5710.0999.02
Digital Oscilloscope, 1 GHz, 4 channels R&S®RTM2104 5710.0999.04
Hardware options
Mixed Signal Option, 400 MHz R&S®RTM-B1 5710.0901.02
GPIB Interface R&S®RTM-B10 1305.0014.02
Bandwidth upgrade 1)
Bandwidth Upgrade from 200 MHz to 350 MHz R&S®RTM-B201 1326.0665.02
Bandwidth Upgrade from 200 MHz to 500 MHz R&S®RTM-B202 1326.0671.02
Bandwidth Upgrade from 350 MHz to 500 MHz R&S®RTM-B200 5710.0918.02
Bandwidth Upgrade from 200 MHz to 1 GHz R&S®RTM-B203 1326.0688.02
Bandwidth Upgrade from 350 MHz to 1 GHz R&S®RTM-B204 1326.0694.02
Bandwidth Upgrade from 500 MHz to 1 GHz R&S®RTM-B205 1326.0707.02
Software options
Application Package (-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K32) R&S®RTM-PK1 1326.2745.02
I C/SPI Serial Triggering and Decoding
2
R&S®RTM-K1 5710.1443.02
UART/RS-232/RS-422/RS-485 Serial Triggering and Decoding R&S®RTM-K2 5710.1450.02
CAN/LIN Serial Triggering and Decoding R&S®RTM-K3 5710.1466.02
I2S/LJ/RJ/TDM Serial Triggering and Decoding R&S®RTM-K5 5710.0882.02
MIL-STD-1553 Serial Triggering and Decoding R&S®RTM-K6 1317.6835.02
ARINC 429 Serial Triggering and Decoding R&S®RTM-K7 1317.6841.02
History and Segmented Memory R&S®RTM-K15 5710.0899.02
Spectrum Analysis and Spectrogram R&S®RTM-K18 1326.0959.02
Power Analysis R&S®RTM-K31 1317.5745.02
Digital Voltmeter (DVM) R&S®RTM-K32 1326.0907.02
Probes
500 MHz, passive, 10:1, 10 MΩ || 9.5 pF, max. 400 V R&S®RTM-ZP10 1409.7708.02
400 MHz, passive, high-voltage, 100:1, 50 MΩ || 7.5 pF, 1 kV (RMS) R&S®RT-ZH10 1409.7720.02
400 MHz, passive, high-voltage, 1000:1, 50 MΩ || 7.5 pF, 1 kV (RMS) R&S®RT-ZH11 1409.7737.02
1.0 GHz, active, 1 MΩ || 0.8 pF R&S®RT-ZS10E 1418.7007.02
1.0 GHz, active, 1 MΩ || 0.8 pF, R&S®ProbeMeter, micro button R&S®RT-ZS10 1410.4080.02
1.5 GHz, active, 1 MΩ || 0.8 pF, R&S®ProbeMeter, micro button R&S®RT-ZS20 1410.3502.02
100 MHz, high-voltage, active, differential, 8 MΩ || 3.5 pF, 1 kV (RMS) (CAT III) R&S®RT-ZD01 1422.0703.02
1.0 GHz, active, differential, 1 MΩ || 0.6 pF, R&S®ProbeMeter, micro button, R&S®RT-ZD10 1410.4715.02
including 10:1 external attenuator, 1.3 pF, 60 V DC, 42.4 V AC (peak)
1.5 GHz, active, differential, 1 MΩ || 0.6 pF, R&S®ProbeMeter, micro button R&S®RT-ZD20 1410.4409.02
10 MHz, current, AC/DC, 0.01 V/A, 150 A (RMS), BNC R&S®RT-ZC10 1409.7750K02
100 MHz, current, AC/DC, 0.1 V/A, 30 A (RMS), BNC R&S®RT-ZC20 1409.7766K02
120 MHz, AC/DC, 1 V/A, 5 A (RMS) R&S®RT-ZC30 1409.7772K02
2 MHz, current, AC/DC, 0.01 V/A, 500 A (RMS) R&S®RT-ZC05B 1409.8204.02
10 MHz, current, AC/DC, 0.01 V/A, 150 A (RMS), Rohde & Schwarz probe R&S®RT-ZC10B 1409.8210.02
interface
50 MHz, AC/DC, 0.1 V/A, 30 A (RMS), Rohde & Schwarz probe interface R&S®RT-ZC15B 1409.8227.02
100 MHz, current, AC/DC, 0.1 V/A, 30 A (RMS), Rohde & Schwarz probe R&S®RT-ZC20B 1409.8233.02
interface
28
RTM_bro_en_3606-8066-12_v0602.indd 28 15.11.2016 13:42:59
Designation Type Order No
Probe Set for E and H Near-Field Measurements, 9 kHz to 1 GHz R&S®HZ-14 1026.7744.03
Compact Probe Set for E and H Near-Field Measurements, 30 MHz to 3 GHz R&S®HZ-15 1147.2736.02
Probe accessories
Accessory Set for R&S®RTM-ZP10 passive probe R&S®RT-ZA1 1409.7566.02
Spare Accessory Set for R&S®RT-ZS10/10E R&S®RT-ZA2 1416.0405.02
Pin Set for R&S®RT-ZS10/10E R&S®RT-ZA3 1416.0411.02
Mini Clips R&S®RT-ZA4 1416.0428.02
Micro Clips R&S®RT-ZA5 1416.0434.02
Lead Set R&S®RT-ZA6 1416.0440.02
Pin Set for R&S®RT-ZD20 R&S®RT-ZA7 1417.0609.02
N-Type Adapter for R&S®RT-Zxx oscilloscope probes R&S®RT-ZA9 1417.0909.02
Power Supply for R&S®RT-ZC10/20 probes R&S®RT-ZA13 1409.7789.02
External Attenuator, 10:1, 2.0 GHz, 70 V DC, 46 V AC (peak) R&S®RT-ZA15 1410.4744.02
Deskew Fixture for power measurements R&S®RT-ZF20 1800.0004.02
3 GHz, 20 dB Preamplifier, 100 V to 230 V Power Adapter, for R&S®HZ-15 R&S®HZ-16 1147.2720.02
Accessories
Front Cover R&S®RTM-Z1 1305.0272.02
Soft Carrying Bag for R&S®RTM oscilloscopes and accessories R&S®RTM-Z3 1305.0289.02
Transit Case R&S®RTM-Z4 1317.4210.02
Rackmount Kit R&S®ZZA-RTM 1304.8292.00
1)
The bandwidth upgrade is performed at a Rohde & Schwarz service center, where the oscilloscope will also be calibrated.
Warranty
Base unit 3 years
All other items 1 year
Options
Extended Warranty, one year R&S®WE1 Please contact your local
Extended Warranty, two years R&S®WE2 Rohde & Schwarz sales office.
Extended Warranty with Calibration Coverage, one year R&S®CW1
Extended Warranty with Calibration Coverage, two years R&S®CW2
Your local Rohde & Schwarz expert will help you determine the optimum solution for your requirements.
To find your nearest Rohde & Schwarz representative, visit
www.sales.rohde-schwarz.com
Rohde & Schwarz R&S®RTM Digital Oscilloscope 29
RTM_bro_en_3606-8066-12_v0602.indd 29 15.11.2016 13:42:59
Oscilloscope portfolio
R&S® family RTH1000 HMO1002 HMO1202 HMO Compact HMO3000
Vertical
Bandwidth 60/100/200/350/500 MHz 50/70/100 MHz 100/200/300 MHz 70/100/150/200 MHz 300/400/500 MHz (upgradeable)
(upgradeable) (upgradeable) (upgradeable)
Number of channels 2 plus DMM/4 2 4 2/4
V/div 1 MΩ 2 mV to 100 V 1 mV to 10 V 1 mV to 10 V 1 mV to 5 V
V/div 50 Ω – – 1 mV to 10 V 1 mV to 10 V 1 mV to 5 V
(150 MHz and 200 MHz)
Horizontal
Sampling rate 1.25 Gsample/s per channel 500 Msample/s 1 Gsample/s per 1 Gsample/s per channel; 2 Gsample/s per channel;
(4-channel model); per channel channel 2 Gsample/s (2 channels 4 Gsample/s (2 channels cascaded)
2.5 Gsample/s per channel 1 Gsample/s 2 Gsample/s cascaded)
(2-channel model); (2 channels (2 channels
5 Gsample/s (all channels cascaded) cascaded)
cascaded)
Max. memory 125 ksample (4-channel model); 500 ksample; 1 Msample; 1 Msample; 4 Msample;
(per channel/1 channel 250 ksample (2-channel model); 1 Msample 2 Msample 2 Msample 8 Msample
active) 500 ksample
Segmented memory option – – option
Acquisition rate 50 000 waveforms/s 10 000 waveforms/s 2000 waveforms/s 5000 waveforms/s
(200 000 waveforms/s in
segmented memory mode 1))
Trigger
Options advanced, digital trigger elementary (five trigger types) basic (six trigger types) basic (nine trigger types)
(14 trigger types) 1)
Mixed signal option
No. of digital channels 1) 8 16
Sampling rate of digital 1.25 Gsample/s 500 Msample/s 1 Gsample/s 1 Gsample/s 1 Gsample/s
channels
Max. memory of digital 125 ksample 500 ksample 1 Msample 1 Msample 2 Msample
channels
Analysis
Cursor meas. types 3 11 13 12
Stand. meas. functions 35 31
Mask test elementary (tolerance mask around the signal)
Mathematics elementary basic (math on math)
Serial protocols trigger- I C, SPI, UART/RS-232
2
I C, SPI, UART/RS-232, CAN/LIN
2
ing and decoding 1)
Display functions data logger – – –
Applications 1) 999 count DVM (4-channel – – –
model); 10 000 count DMM
(2-channel model)
Compliance testing 1) – – – –
Display and operation
Size and resolution 7", color, 800 × 480 pixel 6.5", color, 640 × 480 pixel 6.5", color, 640 × 480 pixel 6.5", color, 640 × 480 pixel
Operation optimized for touchscreen oper- optimized for fast button operation
ation, parallel button operation
General data
Size (W × H × D) 201 mm × 293 mm × 74 mm 285 mm × 175 mm × 140 mm 285 mm × 175 mm × 140 mm 285 mm × 175 mm × 220 mm
(15.87 in × 7.44 in × 5.59 in) (15.87 in × 7.44 in × 5.59 in) (15.87 in × 7.44 in × 5.59 in) (15.87 in × 7.44 in × 5.59 in)
Weight 2.4 kg (5.3 lb) 2.5 kg (5.5 lb) 2.5 kg (5.5 lb) 3.6 kg (7.9 lb)
Battery lithium-ion, > 4 h – – –
1)
Requires an option.
30
RTM_bro_en_3606-8066-12_v0602.indd 30 15.11.2016 13:43:05
RTM2000 RTE1000 RTO2000
ble) 200/350/500 MHz/1 GHz (upgradeable) 200/350/500 MHz/1/1.5/2 GHz 600 MHz/1/2/3/4 GHz (upgradeable)
(upgradeable)
2/4 2/4 2/4 (only 4 channels in 4 GHz model)
1 mV to 10 V 500 µV to 10 V 1 mV to 10 V (500 µV to 10 V in HD mode 1))
1 mV to 2 V 500 µV to 5 V 1 mV to 5 V (500 µV to 5 V in HD mode 1))
2.5 Gsample/s per channel; 5 Gsample/s per channel 10 Gsample/s per channel;
caded) 5 Gsample/s (2 channels cascaded) 20 Gsample/s (2 channels cascaded in 4 GHz model)
10 Msample; 20 Msample standard: 10 Msample/40 Msample; standard: 50 Msample/200 Msample;
(460 Msample in segmented memory max. upgrade: 50 Msample/200 Msample max. upgrade: 1 Gsample/2 Gsample
mode 1))
option standard standard
12 500 waveforms/s 1 000 000 waveforms/s 1 000 000 waveforms/s
(200 000 waveforms/s in segmented (2 000 000 waveforms/s in (3 000 000 waveforms/s in ultra-segmented memory mode)
memory mode 1)) ultra-segmented memory mode)
basic (seven trigger types) advanced, digital trigger (13 trigger types) advanced, digital trigger (14 trigger types), zone trigger 1)
16 16 16
2.5 Gsample/s 5 Gsample/s 5 Gsample/s
10 Msample; 20 Msample 100 Msample 200 Msample
14 3 3
31 47 47
elementary (tolerance mask around the advanced (freely configurable, hardware-based)
signal)
basic (math on math) advanced (formula editor) advanced (formula editor)
I C, SPI, UART/RS-232, CAN/LIN, I S,
2 2
I C, SPI, UART/RS-232, CAN/LIN, I S,
2 2
I2C, SPI, UART/RS-232, CAN/LIN, I2S, MIL-STD-1553,
MIL-STD-1553, ARINC 429 MIL-STD-1553, ARINC 429, FlexRay™, ARINC 429, FlexRay™, CAN FD, MIPI RFFE, USB 2.0/HSIC,
CAN FD, USB 2.0/HSIC, Ethernet, MDIO, 8b 10b, Ethernet, Manchester, NRZ, SENT, MIPI D-PHY,
Manchester, NRZ, SENT, SpaceWire MIPI M-PHY, SpaceWire
track 1) histogram, trend, track 1) histogram, trend, track 1)
power, digital voltmeter (DVM), spectrum power, 16-bit high definition power, 16-bit high definition, jitter, clock data recovery,
analysis and spectrogram I/Q data, RF analysis
– – USB 2.0, 10/100/1000BASE-T Ethernet, 10GBASE-T Ethernet,
Broad-R Reach® Ethernet, MIPI D-PHY, eMMC
8.4", color, 1024 × 768 pixel 10.4", color, 1024 × 768 pixel 12.1", color, 1280 × 800 pixel
optimized for fast button operation optimized for touchscreen operation,
parallel button operation
m 403 mm × 189 mm × 142 mm 427 mm × 249 mm × 204 mm 427 mm × 249 mm × 204 mm
(15.87 in × 7.44 in × 5.59 in) (16.81 in × 9.8 in × 8.03 in) (16.81 in × 9.8 in × 8.03 in)
4.9 kg (10.8 lb) 8.6 kg (19.0 lb) 9.6 kg (21.2 lb)
– – –
Rohde & Schwarz R&S®RTM Digital Oscilloscope 31
RTM_bro_en_3606-8066-12_v0602.indd 31 15.11.2016 13:43:16
About Rohde & Schwarz
Service that adds value The Rohde & Schwarz electronics group offers innovative
❙ Worldwide solutions in the following business fields: test and mea-
❙ Local and personalized surement, broadcast and media, secure communications,
❙ Customized and flexible
cybersecurity, radiomonitoring and radiolocation. Founded
❙ Uncompromising quality
❙ Long-term dependability more than 80 years ago, the independent company which
is headquartered in Munich, Germany, has an extensive
sales and service network with locations in more than
70 countries.
Sustainable product design
❙❙ Environmental compatibility and eco-footprint
❙❙ Energy efficiency and low emissions
❙❙ Longevity and optimized total cost of ownership
Certified Quality Management Certified Environmental Management
ISO 9001 ISO 14001
Rohde & Schwarz GmbH & Co. KG
www.rohde-schwarz.com
Rohde & Schwarz training
www.training.rohde-schwarz.com
Regional contact
❙❙ Europe, Africa, Middle East | +49 89 4129 12345
customersupport@rohde-schwarz.com
❙❙ North America | 1 888 TEST RSA (1 888 837 87 72)
customer.support@rsa.rohde-schwarz.com
❙❙ Latin America | +1 410 910 79 88
customersupport.la@rohde-schwarz.com
❙❙ Asia Pacific | +65 65 13 04 88
customersupport.asia@rohde-schwarz.com
❙❙ China | +86 800 810 82 28 | +86 400 650 58 96
customersupport.china@rohde-schwarz.com
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG
3606.8066.12 06.02 PDP 1 en
Trade names are trademarks of the owners
PD 3606.8066.12 | Version 06.02 | November 2016 (sk)
R&S®RTM Digital Oscilloscope
Data without tolerance limits is not binding | Subject to change
© 2013 - 2016 Rohde & Schwarz GmbH & Co. KG | 81671 Munich, Germany
3606806612
RTM_bro_en_3606-8066-12_v0602.indd 32 15.11.2016 13:43:16