PACSystems* RX3i CEP Carrier

Important Product Information


GFK-2884G IC695CEP001 & IC694CEE001
October 2016
The PACSystems* RX3i Carrier IC695CEP001 interfaces
a remote node, consisting of one RX3i I/O module, to a
PROFINET I/O Local Area Network (LAN).
The optional RX3i Expansion Carrier IC694CEE001
attaches to the RX3i CEP001 Carrier and provides the
ability to add one additional RX3i IC694 I/O module to
the remote node.
The RX3i CEP001 Carrier functions as a PROFINET IO-
Device. The RX3i CEP001 Carrier’s main Remote I/O
functions include:
• Scanning all the modules within the remote node
(input and output scan)
• Publishing data on the PROFINET network to a
PROFINET IO-Controller at a user-specified
production period
• Receiving data from a PROFINET IO-Controller on
the PROFINET network at a customer-specified
production period
• Managing PROFINET communication and module
configuration between a PROFINET IO-Controller
and modules within the remote node
• Managing the state of the I/O when
communications is lost
• Publishing fault information (alarms, diagnostics,
and such) to the PROFINET IO-Controller
• Provides power to the CEE001 Expansion Carrier

The insertion and removal of I/O modules is the same as in an RX3i Universal Backplane. Refer to the
PACSystems RX3i System Manual (GFK-2314).
The RX3i CEP001 Carrier provides two RJ-45 Ethernet receptacles. It supports 10/100BASE-TX Ethernet
standard interface.

Features
• Full programming and configuration services for all supported RX3i I/O modules using Proficy
Machine Edition (refer to the section Supported I/O Modules.)
• Supports daisy-chain/line, star, or ring (redundant media) network topologies
• Two switched Ethernet ports, two eight-conductor RJ-45 shielded-twisted pair 10/100 Mbps copper
interfaces
• USB port for field updates of firmware using WinLoader
• Supports hot-standby CPU redundancy using PROFINET I/O (requires RX3i CEP001 2.01 GSDML V2.3 or
later)
• Supports HART ® pass through using PROFINET
Note: The USB port is for firmware upgrades only. It is not intended for permanent connection.

®HART is a registered trademark of the HART Communication Foundation of Austin, Texas USA. Any use of the term
HART hereafter in this document, or any document referenced by this document, implies the registered trademark.
© 2014-2016 by General Electric Company. All Rights Reserved.
* Indicates a trademark of General Electric Company and/or its subsidiaries. All other trademarks are the property of
their respective owners.
2 PACSystems* RX3i CEP Carrier
GFK-2884G IC695CEP001 & IC694CEE001
Note: The CEP001 Carrier requires a user-supplied +24 Vdc power source.

Ordering Information
IC695CEP001 RX3i CEP001 Carrier with RJ-45 copper Ethernet interface
IC694CEE001 RX3i CEE001 Expansion Carrier

Specifications
Note: For product standards, general operating specifications, and installation requirements, refer to the
PACSystems RX3i System Manual (GFK-2314).
PROFINET support PROFINET Version 2.3 Class A IO-Device
CPU320/CPU315 Primary Firmware Release 8.95 or later
CPU320/CPU315 Boot Firmware Release 5.10 or later
CPE310/CPE305 Primary Firmware Release 8.95 or later
RX3i Controller version
CPE310/CPE305 Boot Firmware Release 7. 10 or later
required
CRU320 Primary Firmware Release 8.95
CRU320 Boot Firmware Release 5.10 or later
IC695PNC001 PROFINET IO-controller with firmware version 2.26 or later
RXi Controller version RXi Controller, ICRXICTL000, with firmware version 7.80 or later is compatible with CEP001
required up to version 2.01, but is not compatible with CEP001 version 2.30.
Proficy Machine Edition
Version 8.6 with SIM 3 or later
version required
IC695CEP001: 5.25W (0.22 A) at 24 Vdc with or without Expansion Carrier (IC694CEE001)
Power requirements 1
DC power supply input range: 19.2 to 30 Vdc
Module dimensions 177.2 x 51 x 35 mm (6.98” x 2.01” x 1.38”). Same for CEP001 and CEE001.
Operating temperature 0°C to 60°C (32°F to 140°F) maximum surrounding air temperature
Number of Ethernet port IC695CEP001: Two RJ-45 10/100Base-TX receptacles
connectors IC694CEE001: None
IC695CEP001: One Micro-B connector. USB 2.0 compliant running at full-speed (12 MHz)
USB connector (for in device mode
firmware upgrades)
IC694CEE001: None
PNS status and control
32 input status bits and 32 output control bits
bits
I/O data update on the
Configurable: 1ms, 2ms, 4ms, 8ms, 16ms, 32ms, 64ms, 128ms, 256ms and 512ms
PROFINET LAN
Number of IP addresses One; supports Classless Inter-Domain Routing (CIDR)
Number of MAC Three; one per external port and one internal. External MAC addresses are only used for
addresses specialized Ethernet protocols such as MRP or LLDP.
IC695CEP001: One
Number of I/O modules per station
IC695CEP001 with IC694CEE001: Two
I/O station maximum
limits 1024 bytes total
I/O data per station 512 bytes of input data
512 bytes of output data
Configured using Proficy Machine Edition when used with a PACSystems RX3i PROFINET
Configuration Controller module as part of an RX3i High-speed I/O LAN system.
V2.3 GSDML file available for import into 3rd-Party tools.

1 Value does not include the power consumption of the installed I/O modules. When calculating the total power
requirements, add the power consumption of the I/O modules according to the I/O module datasheet.
For public disclosure
PACSystems* RX3i CEP Carrier 3
IC695CEP001 & IC694CEE001 GFK-2884G

Installation Location
This product is intended for use with the RX3i system. Its components are considered open equipment
(having live electrical parts that may be accessible to users) and must be installed in an ultimate enclosure
that is manufactured to provide safety. At a minimum, the enclosure shall provide a degree of protection
against solid objects as small as 12mm (fingers, for example). This equates to a NEMA/UL Type 1
enclosure or an IEC60529 IP20 rating providing at least a pollution degree 2 environment. For details
about installing RX3i rack systems, refer to the PACSystems RX3i System Manual (GFK-2314).

Installation in Hazardous Areas


The following information is for products bearing the UL marking for Hazardous Areas or ATEX marking for
explosive atmospheres:

CLASS 1 DIVISION 2 GROUPS ABCD


• This equipment is an open-type device and is meant to be installed in an enclosure suitable for
the environment that is only accessible with the use of a tool.
• Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or nonhazardous
locations only.
• Warning – EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR
CLASS I, DIVISION 2.
• Warning – WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING
MODULES.

ATEX Zone 2
This module must be mounted in an enclosure certified in accordance with EN60079-15 for use in Zone 2,
Group IIC and rated IP54. The enclosure shall only be able to be opened with the use of a tool.

For public disclosure


4 PACSystems* RX3i CEP Carrier
GFK-2884G IC695CEP001 & IC694CEE001

Normal Operation of Individual LEDs

Power LEDs
The RX3i CEP001 Carrier has two Power LEDs, PWR1 and PWR2 that indicate whether the power is applied
and is within range corresponding to the two power sources.
Green, ON Power is applied at the minimum specified level
OFF Power supply does not have power or has failed

OK LED
The OK LED indicates whether the CEP001 Carrier is able to perform normal operation.
Green, ON RX3i CEP001 is OK
Amber, ON Either the RX3i CEP001 Carrier or I/O module has a fault
Amber, blink pattern Fatal error- flashes once between error codes
Fast blinking CEP001 has no valid MAC addresses
OFF CEP001 has an unrecoverable fault

Connect LED
The CONN LED indicates the status of PROFINET connections.
Green, ON At least one PROFINET connection (AR) exists with an IO-Controller
Amber, blink pattern Fatal error- flashes once between error codes blinked on the OK LED
Amber, blink in 1Hz No device name configured
OFF No PROFINET connection (AR) exists

Port LEDs
The RX3i CEP001 has two Port LEDs, PRT1 and PRT2 that indicate link speed, link connection and link
activity corresponding to the two external Ethernet ports.
Green, ON Link connected, 100 Mbps
Green, blinking Port active, 100 Mbps
Amber, ON Link connected, 10 Mbps
Amber, blinking Port active, 10 Mbps
Amber, blink pattern Fatal error - flashes once between error codes blinked on the OK LED
OFF Associated Ethernet port is not connected to an active link (can be disabled
by configuration)
Note: Multiple LEDs can blink in patterns that indicate special conditions, such as a request for module
identification. Refer to PACSystems RX3i PROFINET Scanner IC695CEP001 User Manual (GFK-2883).

Power LED (IC694CEE001)


The RX3i Expansion Carrier CEE001 has one PWR LED to indicate whether the power provided by the RX3i
CEP001 Carrier is within range.
Green, ON OK
Amber, ON Power 24Vdc and/or 5Vdc is not in specified range
OFF No power

For public disclosure


PACSystems* RX3i CEP Carrier 5
IC695CEP001 & IC694CEE001 GFK-2884G

Quick Start

Carrier Installation Requirements


The CEP001 Carrier and optional Expansion Carrier CEE001
can be mounted on a DIN-rail or on a panel.
Adequate installation space is required for:
• Clearance for communications port cables.
• Power wiring.
• Operating the DIN latch.
The RX3i CEP001 Carrier with an I/O module attached requires
an enclosure with minimum depth of 165 mm.
Rated thermal specifications are based on a clearance of
5.1 cm (2”) above and below the equipment and 2.54 cm (1”) to
the left of the RX3i CEP001 Carrier.

Connecting the CEE001 Expansion Carrier to the CEP001 Carrier

 To connect the CEE001 Expansion Carrier to the CEP001 Carrier


1. Open the connector cap on the RX3i CEP001 Carrier.
2. Slide and install the RX3i CEE001 Expansion Carrier along the guide slots on the RX3i CEP001 Carrier.
3. When the Expansion Carrier is aligned with the CEP001 Carrier, engage the expansion connectors.
4. Close the connector cap.
5. Secure the Expansion Carrier to the DIN rail or panel. Refer to the sections Installing an RX3i CEP001
Carrier on a DIN-rail or Panel Mounting.
6. Connect the grounding hole on the CEE001 to the panel or enclosure as described in the section
Grounding.

For public disclosure


6 PACSystems* RX3i CEP Carrier
GFK-2884G IC695CEP001 & IC694CEE001

Installing an RX3i CEP001 Carrier on a DIN-rail


The carrier mounts on a standard EN 50022,
35 x 7.5 mm DIN-rail. Conductive (unpainted) finish is
required for proper grounding.
For best resistance to vibration, the DIN-rail should be
installed horizontally on a panel using screws spaced
approximately 15 cm (6”) apart.

 To install an RX3i CEP001 Carrier on a DIN-rail


1. With a small flathead screwdriver, pull out the two DIN-rail latches and stand the carrier on the DIN-
rail.
2. Push in the two DIN-rail latches so that the latches hold the DIN-rail.

Panel Mounting
For applications requiring maximum or long term resistance to mechanical vibration and shock, the
panel-mounting method is strongly recommended. A minimum panel thickness of 2.4 mm (.093”) is
required. The mounting diagram below applies to both the CEP001 Carrier and CEE001 Expansion Carrier.
Note 1: Tolerances on all dimensions are ±0.2 mm (0.078”) non-cumulative.
Note 2: Apply 1.1 to1.4 Nm (10 to12 in/lbs) of torque to M3.5 (#6-32) steel screws threaded into tapped
holes in the panel.

For public disclosure


PACSystems* RX3i CEP Carrier 7
IC695CEP001 & IC694CEE001 GFK-2884G

Grounding

All CEP001 Carriers in a system must be grounded to minimize electrical shock hazard.
Failure to do so can result in severe personal injury.
Warning

The RX3i CEP001 Carrier and CEE001 Expansion Carrier each provide two grounding connection contacts:
• Grounding clips at the back of the carrier, which require DIN-rail installation
• Grounding screw hole at bottom-left of the carrier
Note: When the Carrier is mounted on a DIN-rail, the grounding clips on the back of the Carrier do not
provide an adequate ground connection. The Carrier’s metal back must also be grounded using a
separate conductor.
Ground each Carrier to the panel or enclosure using a minimum AWG #12 (3.3 mm2) wire with ring
terminals. Use an M3 screw, star lock washer and a flat washer to connect the wire at the Carrier’s
grounding hole. Connect the other end of the ground wire to a tapped hole in the grounded mounting
panel or enclosure, using a machine screw, star lock washer and flat washer. Alternately, if the panel has
a ground stud, use a nut and star lock washer for each wire on the ground stud to ensure adequate
grounding. Where connections are made to a painted panel, the paint should be removed so clean, bare
metal is exposed at the connection point. Terminals and hardware used should be rated to work with the
aluminum carrier material.
Note: The star lock washer method is suitable for a shield ground, but not suitable for a safety ground.

AWG #12 larger wire


2

Screw, star lock washer,


flat washer, ring terminal,
installed in tapped hole.
Paint removed from panel here

For public disclosure


8 PACSystems* RX3i CEP Carrier
GFK-2884G IC695CEP001 & IC694CEE001

Installing Modules on the Carrier


The insertion and removal of I/O modules is the same as in an RX3i Universal Backplane. For details, refer
to GFK-2314, PACSystems RX3i System Manual.

Do not install a Power Supply module on the CEP001 or CEE001 Carrier. Attempting to do so
could damage the module and/or the Carrier.
Caution

Unsupported Modules

If an unsupported module is inserted in the CEP001 or CEE001 Carrier, the module will not
be recognized correctly and could cause damage to the Carrier or the module.
Caution

When an unsupported I/O module is inserted into either the RX3i CEP001 Carrier or RX3i CEE001
Expansion Carrier, no alarm is reported to indicate this.
For the latest updated list of supported I/O modules, refer to the section Supported I/O Modules.
Some unsupported I/O modules have the same Distinguishing Class (for example, IC694MDL740 has the
same Distinguishing Class as IC694MDL742).

For public disclosure


PACSystems* RX3i CEP Carrier 9
IC695CEP001 & IC694CEE001 GFK-2884G

Connecting Power Supplies


You will need:
Note: Two power supplies are required if using redundant power supplies.
 One 24 Vdc power supply which provides a low voltage/limited current (LVLC) power source. (For
example, the combination of an isolated DC supply and a fuse, listed 30 Vdc minimum and 3 A
maximum, connected in series with the input.)
 Power cord with 28 to16 AWG / 0.08 to1.32 mm2 wires
 Ferrules for 28 to16 AWG wires (optional)
 Frame ground wire, 28 to16 AWG
 Input power terminal block; provided (Dinkle part number 0156-2B-B3269806BK)
 Small flathead screwdriver (jeweler’s size 14)
Note: For CE Mark purposes, input power lines to the CEP001 Carrier should be limited 30 m (98 ft)
or less.
Note: Before inserting the wires into the power connector terminal block, use a small flathead
screwdriver to press the spring on the terminal block.
 To connect the power supply
1. Using the power cord, attach the power supply to the power terminal block as displayed in the
following figure.
Recommended wire stripping length is 6 to7 mm (0.25”).
2. If using redundant power supplies, connect the second power supply to the input power
terminal block.
3. Insert the input power terminal block into the Input Power connector.
Note: There are no user-serviceable fuses in the CEP001 Carrier.

PWR1: 24VDC+ GND FGND

PWR2: 24VDC+ GND FGND

Connecting Power to RX3i CEP001 Carrier

For public disclosure


10 PACSystems* RX3i CEP Carrier
GFK-2884G IC695CEP001 & IC694CEE001

Adding a Redundant Power Supply


 To add a redundant power supply to a system that is already in operation
1. Remove power from the primary power supply to the RX3i CEP001 carrier
2. Remove the power terminal block from the carrier.
3. Without disturbing the primary power supply input lines, connect the redundant power supply
input lines to the power terminal block.
4. Insert the power terminal block into the Input Power connector.
5. Apply power to the redundant power supply. The PWR2 LED on the RX3i CEP001 carrier should
turn on.
6. Apply power to the primary power supply. The PWR1 LED on the CEP001 Carrier should turn on.
Note: For the procedure to swap a redundant power supply, refer to PACSystems RX3i PROFINET
Scanner IC695CEP001 User Manual, GFK-2883.

Connecting the CEP001 to the PROFINET Network


The two external RJ-45 Ethernet ports, which provide 10/100 Mbps copper interfaces, are on the bottom
of the CEP001 Carrier.

Devices connected to the RX3i CEP001 ports should have Ethernet Auto-negotiation enabled. The RX3i
CEP001 Carriers and other participating devices can be connected in a daisy-chain/line, or star topology.

Do not connect both ports on the Ethernet interface, directly or indirectly, to the same device
so as to form a circular network unless Media Redundancy is enabled with one node actively
set up as the Media Redundancy Manager.
Caution

For public disclosure


PACSystems* RX3i CEP Carrier 11
IC695CEP001 & IC694CEE001 GFK-2884G

Supported Network Media Types and Distances


PROFINET I/O over-wired infrastructure must be 100Mbps full-duplex or faster. The hardware is capable of
operating at 10Mbps but should not be used for PROFINET.
Core Modal
Connector Wavelength Maximum
Media Type Media Type Size Bandwidth
Type (nm) Distance
(μm) (MHz – Km)
10/100BASE-TX RJ-45 - CAT5/CAT5e/CAT6 - - 100 m (328 ft)

Assigning an I/O Device Name to the CEP001


Before attempting to connect to or configure the CEP001, the I/O Device Name must be set with a
Discovery and Configuration Protocol (DCP) tool.

Configuring the CEP001/CEE001 Node and Resident I/O Modules on a PROFINET Network
Proficy Machine Edition is the primary tool used to configure an RX3i PROFINET network. The GSDML file
for the RX3i CEP001 is included with Proficy Machine Edition, or may be downloaded from the support
website at http://support.ge-ip.com. To obtain the GSDML for import into a 3rd-Party tool, contact GE.

Supported I/O Modules


The following table indicates the minimum CEP001 firmware version required for compatibility with the
listed I/O modules and whether the module can be installed in the RX3i Expansion Carrier CEE001.
Earliest
Distin- CEE001 3
Catalog CEP001
Module Description guishing Comp-
Number Compatible
Classes 2 atible
Version
Discrete Input Modules
IC693MDL230 8 Circuit Input 120 Vac Isolated 8 in 2.30 Y
IC693MDL231 8 Circuit Input 240 Vac Isolated 8 in 2.50 Y
IC693MDL240 16 Circuit Input 120 Vac 16 in 2.30 Y
IC693MDL241 16 Circuit Input 24 Vac / Vdc 16 in 2.50 Y
IC693MDL260 32 Circuit Input 120 Vac, Input Filtering Off 32 in 2.50 Y
IC693MDL260 32 Circuit Input 120 Vac, Input Filtering On 32 in/32 out 2.50 Y
IC693MDL632 8 Circuit Input 125 Vdc Positive / Negative Logic 8 in 2.30 Y
IC693MDL634 8 Circuit Input 24 Vdc Positive / Negative Logic 8 in 2.50 Y
IC693MDL635 16 Circuit Input 125 Vdc Positive / Negative Logic 16 in 2.30 Y
IC693MDL645 16 Circuit Input 24 Vdc Positive / Negative Logic 16 in 2.40 Y
IC693MDL648 16 Circuit Input 48 Vdc Positive / Negative Logic Fast 16 in 2.30 Y
IC693MDL654 32 Circuit Input 5/12 Vdc Positive / Negative Logic 32 in 2.50 Y
IC693MDL655 32 Circuit Input 24 Vdc Positive / Negative Logic Fast 32 in 2.50 Y
32 Circuit Input 24 Vdc Positive / Negative Logic, Input
IC693MDL660 32 in 2.30 Y
Filtering Off
32 Circuit Input 24 Vdc Positive / Negative Logic, Input
IC693MDL660 32 in/32 out 2.30 Y
Filtering On
IC694MDL230 8 Circuit Input 120 Vac Isolated 8 in 2.30 Y
IC694MDL231 8 Circuit Input 240 Vac Isolated 8 in 2.50 Y

2 The RX3i CEP Carrier and the RX3i CEP Expansion Carrier currently does not support fault reporting or “Interrupts”
from this module.
3 The RX3i CEP Carrier and the RX3i CEP Expansion Carrier currently does not support all HART features in this module.

HART® Pass Through or Remote Get HART Device Information COMMREQ support only (no HART variables in IO
Data). HART-compatible CPU and PNC001 versions are required.
The RX3i CEP Carrier and the RX3i CEP Expansion Carrier cannot distinguish between modules within the same
Distinguishing Class type. This means that any module physically present that is within the same class as the one
configured will not alert the user with a System Configuration Mismatch fault on the Controller Fault Table. Refer to
GFK-2222 Chapter 3 for CPU operation during System Configuration Mismatch faults.

For public disclosure


12 PACSystems* RX3i CEP Carrier
GFK-2884G IC695CEP001 & IC694CEE001
Earliest
Distin- CEE001 3
Catalog CEP001
Module Description guishing Comp-
Number Compatible
Classes 2 atible
Version
IC694MDL240 16 Circuit Input 120 Vac 16 in 2.30 Y
IC694MDL241 16 Circuit Input 24 Vac / Vdc 16 in 2.50 Y
IC694MDL250 16 Circuit Input 120 Vac Isolated None 1.00 Y
IC694MDL260 32 Circuit Input 120 Vac None 2.50 Y
IC694MDL632 8 Circuit Input 125 Vdc Positive / Negative Logic 8 in 2.30 Y
IC694MDL634 8 Circuit Input 24 Vdc Positive / Negative Logic 8 in 2.50 Y
IC694MDL635 16 Circuit Input 125 Vdc Positive / Negative Logic 16 in 2.30 Y
IC694MDL645 16 Circuit Input 24 Vdc Positive / Negative Logic 16 in 2.40 Y
IC694MDL646 16 Circuit Input 24 Vdc Positive / Negative Logic Fast 16 in 1.00 Y
IC694MDL648 48 Vdc Input Pos/Neg Fast (16 Points) 16 in 2.30 Y
IC694MDL654 32 Circuit Input 5/12 Vdc Positive / Negative Logic 32 in 2.50 Y
IC694MDL655 32 Circuit Input 24 Vdc Positive / Negative Logic Fast 32 in 2.50 Y
IC694MDL658 32 Circuit Input 48 Vdc Positive / Negative Logic Fast 32 in 2.50 Y
IC694MDL660 32 Circuit Input 24 Vdc Positive / Negative Logic None 2.30 Y
IC695MDL664 16 Circuit Input with diagnostic None 1.00 N
Discrete Output Modules
IC693MDL310 12 Circuit Output 120 Vac 0.5A 16 out 2.50 Y
IC693MDL330 8 Circuit Output 120/240 Vac 2A 8 out 2.40 Y
IC693MDL340 16 Circuit Output 120 Vac 0.5A 16 out 2.50 Y
IC693MDL350 16 Circuit Output 120/240 Vac Isolated 16 out 2.50 Y
IC693MDL390 5 Circuit Output 120/240 Vac 2A Isolated 8 out 2.30 Y
IC693MDL732 8 Circuit Output 12/24 Vdc 0.5A Positive 8 out 2.50 Y
IC693MDL734 6 Circuit Output 125 Vdc 1A Positive/Negative 8 out 2.50 Y
IC693MDL740 16 Circuit Output 12/24 Vdc 0.5A Positive 16 out 2.50 Y
IC693MDL741 16 Circuit Output 12/24 Vdc 0.5A Negative 16 out 2.50 Y
IC693MDL752 32 Circuit Output 5/24 Vdc 0.5A Negative 32 out 2.50 Y
IC693MDL753 32 Circuit Output 12/24 Vdc 0.5A Positive 32 out 2.50 Y
IC693MDL754 32 Circuit Output 24 Vdc 0.75A Positive, Diagnostics Off 32 out 2.30 Y
IC693MDL754 32 Circuit Output 24 Vdc 0.75A Positive, Diagnostics On 32 in/32 out 2.30 Y
IC693MDL930 8 Circuit Output 4A Relay Isolated 8 out 2.30 Y
IC693MDL931 8 Circuit Output Relay Form BC Isolated 8 out 2.50 Y
IC693MDL940 16 Circuit Output 2A Relay 16 out 2.30 Y
IC694MDL310 12 Circuit Output 120 Vac 0.5A 16 out 2.50 Y
IC694MDL330 8 Circuit Output 120/240 Vac 2A 8 out 2.40 Y
IC694MDL340 16 Circuit Output 120 Vac 0.5A 16 out 2.50 Y
IC694MDL350 16 Circuit Output 120/240 Vac Isolated None 2.50 Y
IC694MDL390 5 Circuit Output 120/240 Vac 2A Isolated None 2.30 Y
IC693MDL732 8 Circuit Output 12/24 Vdc 2A Positive 8 out 2.50 Y
IC693MDL734 6 Circuit Output 125 Vdc 1A Positive/Negative 8 out 2.50 Y
IC694MDL740 16 Circuit Output 12/24 Vdc 0.5A Positive 16 out 2.50 Y
IC694MDL741 16 Circuit Output 12/24 Vdc 1A Negative 16 out 2.50 Y
IC694MDL742 16 Circuit Output 12/24 Vdc 1A Positive 16 out 1.00 Y
IC694MDL752 32 Circuit Output 5/24 Vdc 0.5A Negative 32 out 2.50 Y
IC694MDL753 32 Circuit Output 12/24 Vdc 0.5A Positive 32 out 2.50 Y
IC694MDL754 32 Circuit Output with ESCP None 2.30 Y
IC694MDL916 16 Circuit Output 4A Relay None 1.00 Y
IC694MDL930 8 Circuit Output 4A Relay Isolated 8 out 2.30 Y
IC694MDL931 8 Circuit Output Relay Form BC Isolated 8 out 2.50 Y
IC694MDL940 16 Circuit Output 2A Relay 16 out 2.30 Y
IC695MDL765 16 Circuit Smart Output 24/125 Vdc 2A Positive Logic None 1.00 N
Mixed Discrete Input/Output Modules
IC693MDR390 8 Circuit Mixed 24 Vdc Input / Relay Output 8 in/8 out 2.40 Y
IC693MAR590 8 Circuit Mixed 120 Vac Input / Relay Output 8 in/8 out 2.30 Y
IC694MDR390 8 Circuit Mixed 24Vdc Input/Relay Output 8 in/8 out 2.40 Y

For public disclosure


PACSystems* RX3i CEP Carrier 13
IC695CEP001 & IC694CEE001 GFK-2884G
Earliest
Distin- CEE001 3
Catalog CEP001
Module Description guishing Comp-
Number Compatible
Classes 2 atible
Version
Analog Input Modules
IC693ALG222 16 Point Analog Voltage Input ALG IN 16 2.50 Y
IC693ALG223 16 Point Analog Current Input ALG IN 16 2.50 Y
IC694ALG222 16 Point Analog Voltage Input ALG IN 16 2.50 Y
IC694ALG223 16 Point Analog Current Input ALG IN 16 2.50 Y
IC695ALG112 12 Point Isolated Analog Current/Voltage Input None 2.01 N
IC695ALG600 8 point Universal Analog Input Module None 2.01 N
IC695ALG616 16 Point Analog Current / Voltage Input2 None 1.00 N
16 Point Analog Current / Voltage Input (HART
IC695ALG626 None 1.00 4 N
Support)2,3
Analog Output Modules
IC693ALG392 8 Point Analog Current / Voltage Output ALG OUT 8 2.50 Y
IC694ALG392 8 Point Analog Current / Voltage Output ALG OUT 8 2.50 Y
IC695ALG704 4 Point Analog Current / Voltage Output None 2.50 N
IC695ALG708 8 Point Analog Current / Voltage Output None 2.50 N
8 Point Analog Current / Voltage Output (HART
IC695ALG728 None 1.004 N
Support)2,3
IC695ALG808 8 Point Isolated Analog Current / Voltage Output 2 None 1.00 N
Analog Mixed Modules
ALG IN 4,
IC693ALG442 4 Input / 2 Output, Current / Voltage 2.30 Y
ALG OUT 2
ALG IN 4,
IC694ALG442 4 Input / 2 Output, Current / Voltage 2.30 Y
ALG OUT 2
Thermocouple Input Modules
IC695ALG312 12 Point Isolated Thermocouple Input None 2.50 N
High-speed Counter Modules
High-Speed Counter Module, 1.5MHz, 16 Inputs,
IC695HSC308 None 2.40 N
14 Outputs
Specialty Modules
IC694PSM001 Power Sync and Measurement Module None 2.01 Y

4 The RX3i CEP001 Carrier and the RX3i CEE001 Expansion Carrier do not support Interrupts from this module.
The RX3i CEP001 Carrier does not support HART features which are logic-driven. HART data obtained via HART Pass
Through is available.
RX3i CEP001 version 2.30 is required for HART Pass Through functionality. Refer to additional Compatibility
information below.
For public disclosure
14 PACSystems* RX3i CEP Carrier
GFK-2884G IC695CEP001 & IC694CEE001

Important Product Information

Release History
Firmware
Version Date Comments
Release
Added support for the Remote Get HART Device Information
COMMREQ. Information from a HART device connected to an RX3i
IC695CEP001-AAAG 2.60 Oct 2016 Analog Module in an IC695CEP001 RX3i CEP Carrier may be read
into the user application using the Remote Get HART Device
Information COMMREQ.
Added support for additional I/O Modules (refer to the section
IC695CEP001-AAAF 2.50 Dec 2015
Supported I/O Modules)
Added support for additional I/O Modules (refer to the section
IC695CEP001-AAAE 2.40 June 2015
Supported I/O Modules)
Added support for additional I/O Modules (refer to the section
IC695CEP001-AAAD 2.30 June 2015
Supported I/O Modules) and for HART pass through functionality.
Added Hot-standby CPU redundancy using PROFINET I/O and
IC695CEP001-AAAC 2.01 Nov 2014 support for additional RX3i I/O modules: IC695ALG112,
IC695ALG600, and IC694PSM001
IC695CEP001-AAAA 1.00 Jan 2014 Initial release

Upgrades
Upgrade kit: 41G1897-MS10-000-A5.zip is available at http://support.ge-ip.com.

Compatibility
The PROFINET Scanner modules require the CPU firmware and programming software versions listed in
the following table.
Proficy Machine Edition Proficy Machine Edition version 8.6 SIM 3 or later
PACSystems RX3i CPU,
CPU320/CPU315 Primary Firmware Release 8.95 or later
CPU320/CPU315 Boot Firmware Release 5.10 or later
RX3i CPU Version CPE310/CPE305 Primary Firmware Release 8.95 or later
CPE310/CPE305 Boot Firmware Release 7. 10 or later
CRU320 Primary Firmware Release 8.95
CRU320 Boot Firmware Release 5.10 or later
PACSystems RX3i PROFINET IO-Controller, IC695PNC001, with firmware version 2.26
RX3i PNC Version
or later
Effective with IC695CEP001 Firmware version 2.30, the PACSystems RXi Distributed
RXi Controller Version I/O Controller, ICRXICTL000, is no longer compatible with IC695CEP001. ICRXICTL000
with firmware version 7.80 or later may be used with CEP001 version 2.01 or earlier.
For a complete list of modules supported by the current firmware release, refer to the
RX3i I/O Modules
section, Supported I/O Modules, above.
HART Pass Through entails usage of PC-based applications, RX3i Analog modules
with HART functionality and (optionally) supporting PROFINET products. HART Pass
HART Pass Through
Through operation is described in the PACSystems HART Pass Through User Manual,
GFK-2929.

Problems Resolved in This Release


Feature Description
None Release provides support for additional I/O modules only.

For public disclosure


PACSystems* RX3i CEP Carrier 15
IC695CEP001 & IC694CEE001 GFK-2884G

New Features and Enhancements


Feature Description
Release 2.60 adds support for the Remote Get HART Device Information COMMREQ.
Support for COMMREQ 1 - Information from a HART device connected to an RX3i Analog Module in an
Remote Get HART Device IC695CEP001 RX3i CEP Carrier may be read into the user application using the
Information Remote Get HART Device Information COMMREQ.
Note: When upgrading for HART functionality, the CPU and PNC001 must also be
upgraded.
Power supply connector The power supply connectors have been changed to increase the robustness of the
changed contacts among the plug and the socket

Restrictions and Open Issues


Restriction / Issue Description
When configuring RX3i CEP001 under PROFINET HSB redundancy, if you pull the I/O
Pulling and plugging a module installed on an RX3i CEP001 while switching the current primary/backup CPU
module during HSB roll role, then plug the I/O module back in and switch the primary/backup CPU role back,
switch can make the I/O the I/O module might be lost.
module not able to be
It is not suggested to pull/plug an I/O module during PROFINET HSB redundancy roll
recognized.
switch. To recover, cycle power to the RX3i.
Whenever fault reporting is configured for an I/O module, and a fault occurs and is
Module diagnosis alarms are
subsequently resolved, the fault might not be reported via the PROFINET diagnosis
not stable, especially when
appears / diagnosis disappears alarm sequence. This situation is more likely to be
multiple diagnoses appear at
encountered when multiple alarms occur in rapid succession. Refer to Diagnosis
same time.
Disappears alarms may be out of sequence with Diagnosis Appears alarms below.
The RX3i CEP001 GSDML does not have the attribute InterfaceSubmoduleItem/
ApplicationRelations/@StartupMode. The default is Legacy according to the GSDML
When supporting PROFINET
specification. This setting does not matter for simplex. However, for PROFINET System
System Redundancy, set
Redundancy the StartupMode needs to be set to Advanced. Refer to Protocol (IEC
StartupMode to Advanced
61158-6-10) in IO APDU Substitutions. The SRInfoBlock required for System
Redundancy is only available in IODConnect.Req with StartupMode:=1.
Hot swap of ALG626 module
Whenever the IC695ALG626 module is hot swapped while online with sixteen HART
while Online with attached
devices attached to it, the IC695CEP001 may enter a blink trap1-2. To recover, cycle
HART device causes CEP
power to the CEP001.
blink trap 1-2.
CEP does not detect the ALG312 module, when it is hot inserted. This can be observed
in the Profinet Controller, where "Addition of IO Module" is not reported and ALG312
module OK LED keeps blinking.
IC695ALG312 module is not
detected after hot insertion
To overcome this, CEP should be power cycled. After the power cycle CEP properly
detects ALG312 module and “Addition of IO Module” is reported with LED become
solid green.

For public disclosure


16 PACSystems* RX3i CEP Carrier
GFK-2884G IC695CEP001 & IC694CEE001

Operational Notes
Note Description
HART pass through feature If used specifically for HART Pass Through, the supporting RX3i PROFINET Controller
for IC695ALG626, (PNC001) and PROFINET Scanner (PNS001 or CEP001) must also contain HART-
IC695ALG628 5 & compatible firmware:
IC695ALG728 modules IC695PNC001-AK Firmware Release 2.30
IC695PNS001-ABAH Firmware Release 2.30
IC695CEP001-AAAD Firmware Release 2.30.
Whenever an unsupported I/O module is inserted into either the RX3i CEP001 Carrier
or RX3i CEE001 Expansion Carrier, no alarm is reported to indicate this.
No alarm report when For a list of supported I/O modules, refer to the section, Supported I/O Modules.
inserting an unsupported I/O Some unsupported I/O modules have the same Distinguishing Class (for example,
module IC694MDL740 has the same Distinguishing Class as IC694MDL742). If an unsupported
module is inserted in the CEP001 or CEE001 Carrier, the module will not be
recognized correctly.
If, while using WinLoader, power is lost to the RX3i CEP001 Carrier during a firmware
Wait time is too long to enter
update, a delay of more than 50 seconds might be required before the RX3i CEP001
download mode
Carrier can enter the firmware update mode again.
When connecting the USB cable to the RX3i CEP001 Carrier, you may receive a
warning for installing a driver that has not passed Windows® Logo testing.
USB port drivers Each RX3i CEP001 Carrier is recognized as a separate Windows device with separate
installation, as each has a unique serial number. This is normal operation for this
release.
If the network parameters (IP Address, subnet mask, and gateway IP) assigned by the
DCP tool are different from the configuration in the IO-Controller and the
Network parameters for IO-Controller is configured to assign IP settings to devices, when the I/O Controller
IO-devices assigns its IP settings, the settings previously stored from the DCP tool are lost. On a
reset, the IO-Device is set to factory default values (0.0.0.0/0.0.0.0/0.0.0.0) as
prescribed by the PROFINET specification.
The RX3i CEP001 Carrier and RX3i CEE001 Expansion Carrier ignore all extra
No Extra Module alarms equipment. No Extra I/O Module faults or Loss of I/O Module faults are generated for
unconfigured modules.
For RX3i Intelligent modules Diagnosis Disappears alarms are generated by cyclically
polling diagnostic data. These alarms may be slower than Diagnosis Appears alarms
from the same module, which are generated by an interrupt.
Example: When re-applying field power, new channel alarms such as Hi/Low alarms
may occur before the Loss of Field Power alarm clears.
Diagnosis Disappears alarms
Affected modules are:
may be out of sequence with
Diagnosis Appears alarms IC695MDL664
IC695MDL765
IC695ALG616
IC695ALG626
IC695ALG728
IC695ALG808
RXi Support RXi Controller do not support for RX3i CEP Rel. 2.30
CEP001 fails to show
attached I/O module in If there is no hardware configuration in the controller, and the PROFINET network is
PROFINET network scan subsequently scanned, the scan may show no I/O module present in CEP001, even
when hardware when an I/O module is physically present.
configuration is absent
Whenever an I/O module attached to CEP001 is physically changed, and the
Generic I/O module hardware configuration is not updated, the I/O module may show as a Generic IO
module in a subsequent PROFINET network scan.

5 If used, IC695ALG628 must be installed in the RX3i CPU Rack. At time of publication, it is not supported by PROFINET
scanners IC695PNS001 or IC695CEP001. Refer to IPIs for IC695PNS001 or IC695CEP001 for future updates.
For public disclosure
PACSystems* RX3i CEP Carrier 17
IC695CEP001 & IC694CEE001 GFK-2884G

Note Description
GE Device Essentials software (v 01.04.00) may stop responding when trying to view
View live data for more than live data for more than 30 number of HART devices simultaneously.
30 devices simultaneously Recommended to view HART data for less than 30 devices simultaneously. (Not to
include into IPI)

Additional Information
Manuals can be downloaded from the support website at http://support.ge-ip.com.
PACSystems RX3i PROFINET Scanner IC695CEP001 User Manual GFK-2883
PACSystems RX3i PROFINET Controller User Manual GFK-2571
PACSystems RX3i PROFINET Controller Command Line Interface Manual GFK-2572
PACSystems RX7i & RX3i CPU Reference Manual GFK-2222
PACSystems RX7i & RX3i CPU Programmer’s Reference Manual GFK-2950
PACSystems RX3i System Manual GFK-2314
PACSystems RX3i HART Pass Through User’s Manual GFK-2929