Doc. No.

: FM/CUM/QAQC/REC04

INSPECTION REPORT Effec. Date : 1 Februari 2018


(LAPORAN HASIL INSPEKSI) Revision : 0

Customer : PT. CLARIANT KUJANG CATALYST Report No. : 26/04/IR/18


Equipment Name : Tray stainless 430 So / Po No. : 02580
Item Serial : : 1
Quantity
Drawing No. : CUM18-02580-CKC-00 Page : 1
Request for Inspection

RECEIVING MATERIAL FIT- UP SANDBLASTING & PAINT HYDROTEST PACKING / DELIVERY

CUTTING/MARKING WELDING BALANCING HARDNESS TEST

BENDING ROLLING ASSEMBLY DIMENSI / FINAL CHECK RUNNING TEST


RESULT OF INSPECTION : Requested by :

(HASIL DARI INSPEKSI)

Dimension
No Item Description Tolerance Result Remarks
Drawing Actual
1 A Side Length 1 900 898 Accepted
2 B Wide Length 1 900 899 Accepted
3 C Wide Length 2 900 900 Accepted
4 D Wide Length 3 900 899 Accepted
5 E Length Leg 50 50 Accepted

PREPARED INSPECTED BY REVIEWED / APPROVED BY RESULT QTY.

ACC

REPAIR

REJECT

HOLD
(…………………………………….) (………………………………...)