PRODUCT DATASHEET
LCF12-50JFN
1/2" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable
CELLFLEX® 1/2" low loss flexible cable; flame retardant/ halogen free jacket
FEATURES / BENEFITS
• Low Attenuation
The low attenuation of CELLFLEX® coaxial cable results in highly efficient signal transferin your
RF system.
• Complete Shielding
The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that
minimizes system interference.
• Low VSWR
Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise.
• Outstanding Intermodulation Performance
CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS
factory.
• High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized
dielectric
materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
• Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas,
wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment
interconnects.
• Meets or Exceeds: IEC 60754-1, -2; IEC 60332-1-1, -2;IEC 61034-1, -2; IEC 60332-3-24
(formerly IEC 60332-3-C)
Technical features
APPLICATIONS
OEM jumpers, Main feed transitions to equipment, GPS lines, Riser-rated In-Building, CPR
Applications
classified cable
STRUCTURE
Cable Type Foam-Dielectric, Corrugated
Size 1/2
Inner Conductor Diameter mm (in) 4.8 (0.19)
Inner Conductor Material Copper-Clad Aluminum Wire
Dielectric Diameter mm (in) 11.3 (0.44)
Dielectric Material Foam Polyethylene
Outer Conductor Diameter mm (in) 13.8 (0.54)
Outer Conductor Material Corrugated Copper
Jacket Diameter mm (in) 15.8 (0.62)
Jacket Material Black Polyethylene, Metalhydroxite Filling
TESTING AND ENVIRONMENTAL
Fire Performance Flame Retardant, LS0H
Meets/Exceeds: IEC 60754-1, -2; IEC 60332-1-1, -2;
Flame Retardant Jacket IEC 61034-1, -2; IEC 60332-3-24 (formerly IEC 60332-3-C);
Specifications UL 1581; UL 1666; NFPA 130; NEC type CATVR; EN45545-2(GER production);
CPR: https://www.rfsworld.com/searchengine/construction-products-regulation-cpr
Installation Temperature °C(°F) -25 to 60 (-13 to 140)
Storage Temperature °C (°F) -70 to 85 (-94 to 185)
Operation Temperature °C(°F) -50 to 85 (-58 to 185)
LCF12-50JFN REV : W REV DATE : 15 Dec 2023 www.rfsworld.com
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at Page 1 of 3
time of ordering
PRODUCT DATASHEET
LCF12-50JFN
1/2" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable
ELECTRICAL SPECIFICATIONS
Impedance Ω 50 +/- 1
Maximum Frequency GHz 8.8
Velocity % 87
Capacitance pF/m (pF/ft) 76 (23.2)
Inductance uH/m (uH/ft) 0.19 (0.058)
Peak Power Rating kW 38
RF Peak Voltage Volts 1950
Jacket Spark Volt RMS 8000
Ω/1000 m
Inner Conductor dc Resistance 1.62 (0.5)
(Ω/1000 ft)
Ω/1000 m
Outer Conductor dc Resistance 3.55 (1.08)
(Ω/1000 ft)
Return Loss (VSWR) Performance Standard or Premium
Min. Return Loss (Max. VSWR) dB (VSWR) Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies
Phase Stabilized Phase stabilized and phase matched cables and assemblies are available upon request.
Temperature & Power Standard
MECHANICAL SPECIFICATIONS
Cable Weight, Nominal kg/m (lb/ft) 0.201 (0.135)
Minimum Bending Radius, Single
mm (in) 70 (3)
Bend
Minimum Bending Radius,
mm (in) 125 (5)
Repeated Bends
Bending Moment Nm (lb-ft) 6.5 (4.79)
Tensile Strength N (lb) 1050 (236)
Recommended / Maximum
m (ft) 0.6 / 1 (2 / 3.25)
Clamp Spacing
LCF12-50JFN REV : W REV DATE : 15 Dec 2023 www.rfsworld.com
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at Page 2 of 3
time of ordering
PRODUCT DATASHEET
LCF12-50JFN
1/2" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable
ATTENUATION @ 20°C (68°F) AND POWER RATING @ 40°C (104°F)
Frequency, MHz dB per 100m dB per 100ft Power, kW
1 0.21 0.07 35.30
100 2.18 0.66 3.45
200 3.12 0.95 2.41
450 4.77 1.45 1.57
700 6.03 1.84 1.24
800 6.48 1.98 1.16
900 6.91 2.10 1.09
1800 10.10 3.07 0.75
2000 10.70 3.26 0.70
2200 11.30 3.44 0.67
2400 11.80 3.61 0.63
2700 12.70 3.86 0.59
3000 13.40 4.09 0.56
3500 14.70 4.47 0.51
4000 15.80 4.83 0.47
5000 18 5.50 0.42
6000 20.70 6.30 0.37
7000 22 6.70 0.34
8800 25.20 7.69 0.30
External Document Links Notes
• LCF12-50JFNTC: TC cables (temperature cycled) are cables that are
aged in order to reduce hysteresis effects. Available upon request.
• Europe ordering code:
LCF12-50JFN-1-50: LCF12-50JFN, 50m length, Carton
LCF12-50JFN-1-100: LCF12-50JFN, 100m length, Carton
LCF12-50JFN-1-240: LCF12-50JFN, 240m length, Drum 06-042-X
LCF12-50JFN-1-500: LCF12-50JFN, 500m length, Drum 08-053-X
LCF12-50JFN REV : W REV DATE : 15 Dec 2023 www.rfsworld.com
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at Page 3 of 3
time of ordering