PROJECT NAME:
CONCRETING WORK INSPECTION CHECKLIST
 INSPECTION DATE : 22/1/24
 PACKAGE NO       : C03&C09(N2&H2)
 CONTRACTOR       : OCS YES Construction
 LOCATION          : Ext. Road 1                        DRAWING NO : FEK2-LAY-ANC-01-SSTR-170-06
 LEVEL/GRIDLINE    : Level 1
                                                               1st Inspection       2nd Inspection     Remark /
Item                       Description                       Yes      No     N/A   Yes    No     N/A   Non-Conformance
  1     Formwork
    a. A 50mm thick lean concrete layer has been in
    b. Setting out / control points for alignment,
        position
    c. Transfer level, drop, step down
    d. Dimension (width & depth/height)
    e. Top level of concrete marking
    f. Tightness of form joints (to prevent grout loss)
    g. Construction joints (level, verticality & position)
    h. Marking/fixing for opening and sleeve (type,
        size
        and position)
     i. Cleanliness of form
     j. Mould oil (if applicable)
  2     Reinforcement Bar
    a. Size and location of spacer as specified
    b. Minimum concrete cover is secured
    c. Condition of reinforcement bar (Securely tied,
        free
    d. Main bar (diameter, number, position, spacing,                                                  Lap length for beam and column
        top                                                                                            52 times bar diameter (min
                                                                                                       600mm)
        hook, lap length, anchorage length)
    e. Link (diameter, number, spacing, hook, cover,
        welding point, penetration rebar)
    f. Starter Bar ( diameter,number,length)
      g. BRC (size, number, position, spacing, lap
         length,
      h. Additional rebars/ trimmer bars / anti crack
         bars for
  3     Others
   a. Position, spacing and rigidity of props /
      scaffoldings
   b. Treatment of existing construction joints (free
      from laitance, exposed aggregate)
   c. Application of waterproofing addmixtures /
      material
   d. Install cast in plate, hook. (If any)
   e. M&E services checked
 REMARK / NON-CONFORMANCE
 Inspected by :                               Inspected and                             Checked and Approved by :
                                              Approved by :
 Name :                                          Name :                                  Name :
 Designation :                                   Designation :                           Designation :
 Date :                                          Date :                                  Date :
* This section is applicable for mock up inspection by consultant only and will be crossed out for daily basis inspection.