SINGLE SPLIT SPECIFICATION
CEILING CONCEALED DUCT
COMMERCIAL
STANDARD INVERTER (R410A) STANDARD INVERTER (R410A)
MID / HIGH STATIC PRESSURE UU18W UU24W MID / HIGH STATIC PRESSURE UU36W UU42W
- CM18 / CM24 / UM30 UU30W - UM36 / UM42 / UM48 / UM60 UU48W
UU60W
LG participates in the ECP programme for EUROVENT AC program. LG participates in the ECP programme for EUROVENT AC program.
Check ongoing validity of certification Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com
INDOOR CM18 N14 CM24 N14 UM30 N14 INDOOR UM36 N24 UM42 N24 UM48 N34 UM60 N34
Cooling Min / Nom / Max kW 1.8 / 5.0 / 6.0 2.8 / 6.8 / 7.5 3.2 / 7.8 / 8.8 Cooling Min / Nom / Max kW 4.0 / 10.0 / 11.0 5.0 / 12.1 / 13.2 5.6 / 14.0 / 15.4 5.9 / 14.8 / 16.3
Capacity Capacity
Heating Min / Nom / Max kW 2.2 / 6.0 / 7.2 3.2 / 7.5 / 8.3 3.6 / 9.0 / 9.9 Heating Min / Nom / Max kW 4.5 / 11.2 / 12.3 5.6 / 14.0 / 15.0 6.6 / 15.8 / 18.2 6.8 / 16.8 / 18.7
Low Temperature Capacity Heating -7°C Max kW 5.4 7.2 8.1 Low Temperature Capacity Heating -7°C Max kW 10.0 12.5 14.8 15.2
Cooling Nom kW 1.46 2.07 2.41 Cooling Nom kW 3.12 3.76 4.10 4.53
Power Input (Set) Power Input (Set)
Heating Nom kW 1.66 2.34 2.62 Heating Nom kW 3.19 3.86 4.39 4.79
Power Input (Indoor) Min / Max (Nom ESP) W 90 / 160 100 / 180 160 / 240 Power Input (Indoor) Min / Max (Nom ESP) W 200 / 360 230 / 380 220 / 340 300 / 430
Running Current Cooling / Heating Nom A 6.5 / 7.6 9.1 / 10.3 10.1 / 10.7 Running Current Cooling / Heating Nom A 13.6 / 13.9 16.6 / 17.2 17.3 / 18.5 19.1 / 20.2
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50
EER 3.41 3.11 3.51 EER 3.21 3.22 3.41 3.31
COP 3.61 3.21 3.70 COP 3.51 3.63 3.60 3.51
SEER 6.10 6.10 6.10 SEER 5.11 5.10 5.20 5.10
SCOP 4.25 3.90 4.00 SCOP 3.81 3.58 3.65 3.65
Pdesign (@ -10°C) kW 4.1 6.0 6.5 Pdesign (@ -10°C) kW 7.8 11.5 12.0 12.0
Seasonal Energy Label Cooling / Heating (A++ to E Scale) A++ / A+ A++ / A A++ / A+ Seasonal Energy Label Cooling / Heating A / A (A++ to E Scale) - - -
Annual Energy Consumption Cooling / Heating kWh 287 / 1,383 390 / 2,154 448 / 2,275 Annual Energy Consumption Cooling / Heating kWh 685 / 2,866 - - -
Liquid mm (inch) Ø6.35 (1/4) Ø9.52 (3/8) Ø9.52 (3/8) Liquid mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8)
Piping Connection Gas mm (inch) Ø12.7 (1/2) Ø15.88 (5/8) Ø15.88 (5/8) Piping Connection Gas mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
Drain O.D. / I.D. mm 32 / 25 32 / 25 32 / 25 Drain O.D. / I.D. mm 32 / 25 32 / 25 32 / 25 32 / 25
Air Flow Rate High / Medium / Low m³/min 16.5 / 14.5 / 13.0 18.0 / 16.5 / 14.5 22.0 / 20.0 / 18.0 Air Flow Rate High / Medium / Low m³/min 32.0 / 28.0 / 24.0 38.0 / 33.0 / 28.0 40.0 / 34.0 / 28.0 50.0 / 45.0 / 40.0
Sound Pressure Cooling High / Medium / Low dBA 34 / 32 / 30 35 / 34 / 32 37 / 35 / 34 Sound Pressure Cooling High / Medium / Low dBA 36 / 34 / 33 38 / 36 / 34 40 / 38 / 36 42 / 40 / 38
Sound Power Cooling Max dBA 59 60 62 Sound Power Cooling Max dBA 60 62 65 66
Dehumidification Rate l/h 2.0 2.5 2.8 Dehumidification Rate l/h 3.2 3.6 4.5 5.0
Dimensions Body WxHxD mm 900 x 270 x 700 900 x 270 x 700 900 x 270 x 700 Dimensions Body WxHxD mm 1,250 x 270 x 700 1,250 x 270 x 700 1,250 x 360 x 700 1,250 x 360 x 700
Net Weight Body kg 23.8 24.2 25.3 Net Weight Body kg 35.0 37.0 42.5 42.5
External Static Pressure Min ~ Max mmAq (Pa) 2.5~15 (25~147) 2.5~15 (25~147) 2.5~15 (25~147) External Static Pressure Min ~ Max mmAq (Pa) 4~15 (39~147) 5~15 (49~147) 5~15 (49~147) 5~15 (49~147)
OUTDOOR UU18W UE4 UU24W U44 UU30W U44 OUTDOOR UU36W UO2 UU42W U32 UU48W U32 UU60W U32
Compressor Type Twin Rotary Twin Rotary Twin Rotary Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin Rotary
Airflow Rate Nom m³/min 50 58 58 Airflow Rate Nom m³/min 90 110 110 110
Cooling Nom dBA 47 48 48 Cooling Nom dBA 53 52 52 52
Sound Pressure Sound Pressure
Heating Nom dBA 52 52 52 Heating Nom dBA 54 54 54 54
Sound Power Cooling Max dBA 63 67 68 Sound Power Cooling Max dBA 66 67 68 71
Dimensions WxHxD mm 870 x 655 x 320 950 x 834 x 330 950 x 834 x 330 Dimensions WxHxD mm 950 x 1,170 x 330 950 x 1,380 x 330 950 x 1,380 x 330 950 x 1,380 x 330
Net Weight kg 44.6 56.1 58.0 Net Weight kg 81.0 92.0 92.0 92.0
Type - R410A R410A R410A Type - R410A R410A R410A R410A
Charge g 1,300 2,000 2,000 Charge g 2,800 3,400 3,400 3,400
Refrigerant Additional Charge g/m 20 40 40 Refrigerant Additional Charge g/m 40 40 40 40
GWP - 2087.5 2087.5 2087.5 GWP - 2087.5 2087.5 2087.5 2087.5
TCO2eq - 2.7 4.2 4.2 TCO2eq - 5.8 7.1 7.1 7.1
Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 Cooling Min ~ Max °C DB -15 ~ 48 -15 ~ 48 -15 ~ 48 -15 ~ 48
Operation Range (Outdoor) Operation Range (Outdoor)
Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18 -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50
Power Supply Cable No. x mm² 3C x 2.5 3C x 2.5 3C x 2.5 Power Supply Cable No. x mm² 3C x 5.0 3C x 5.0 3C x 5.0 3C x 5.0
Transmission Cable No. x mm² 4C x 0.75 4C x 0.75 4C x 0.75 Transmission Cable No. x mm² 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75
Circuit Breaker A 20 25 25 Circuit Breaker A 40 40 40 40
Piping Length Total Min ~ Max m 5 ~ 30 5 ~ 50 5 ~ 50 Piping Length Total Min ~ Max m 5 ~ 50 5 ~ 75 5 ~ 75 5 ~ 75
Piping Elevation Difference IDU - ODU Max m 30 30 30 Piping Elevation Difference IDU - ODU Max m 30 30 30 30
Liquid mm (inch) Ø6.35 (1/4) Ø9.52 (3/8) Ø9.52 (3/8) Liquid mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8)
Piping Connection Piping Connection
Gas mm (inch) Ø12.7 (1/2) Ø15.88 (5/8) Ø15.88 (5/8) Gas mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
Note : 1. Due to our policy of innovation some specifications may be changed without notification. Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Definition of Power Input Nominal conditions – Performance tested under EN14511 2. Definition of Power Input Nominal conditions – Performance tested under EN14511
3. Capacities are based on the following conditions: 3. Capacities are based on the following conditions:
Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB Cooling : - Indoor Temperature 27°C DB / 19°C WB - Outdoor Temperature 35°C DB / 24°C WB Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB
4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition 4. Annual energy consumption : based on average use of 350 running hours in cooling and 1,400 hours in heating per year at seasonal condition
5. This product contains fluorinated greenhouse gases (R410A) 5. This product contains fluorinated greenhouse gases (R410A)
200 201