Kodak NexPress S2100/S2500/S3000 digital production color

pressesInstallation Instructions for the THERMAL VENT KIT

Digital Production Systems

Installation Instructions for the


THERMAL VENT KIT

Edition: April 29, 2005


Available as PDF file only
Publication ID: A11M36
kn.0003413/00
ABC

Imprint/Company Address © 2008 Kodak. All rights reserved. Eastman Kodak Company
No part of this book may be repro- 2600 Manitou Road
duced without prior written permis- Rochester, New York 14653
sion. USA
www.kodak.com
Contact address for European
countries:
Eastman Kodak SA
c/o Kodak GmbH
Hedelfinger Str. 60
D-70327 Stuttgart
Germany
. ...........................................................
Kodak, NexPress, Digimaster and marks or registered trademarks of
NexPert are trademarks of Kodak. the corresponding manufacturers
Other company names, product and fall within the regulations
names and trademarks not expressly regarding the protection of trade-
mentioned in this manual are trade- marks.
. ............................................................
Important notice: cerning application of our products
We are dedicated to improving and is not legally binding as it does not
enhancing our products. Conse- constitute a written contract of fea-
quently, the information in this tures.
manual is subject to change without If any problems occur with the prod-
notice. uct described in this manual, please
Kodak assumes no responsibility for contact the Kodak agency which is
information and description as far responsible for you.
as third-party products are con- Available as PDF file only
cerned. Publication ID: A11M36
The information contained in this Edition: April 29, 2005
manual about performance and Internal ID: kn.0003413/00
speed as well as technical data con- Printed in USA.
1 Introduction

Important Safety Information


This equipment includes parts and assemblies sensitive to damage from
electrostatic discharge. Use caution to prevent damage during all service
procedures.

Pay attention to the following symbols to ensure your safety when working with the
product.

CAUTION: HIGH VOLTAGE, AVOID CONTACT


ATTENTION: EVITER LE CONTACT, HAUTE TENSION
VORSICHT: HOCHSPANNUNG, BERUEHRUNG VERMEIDEN
<01-001>

PRECAUCIÓN: ALTA TENSIÓN, EVITAR EL CONTACTO


ATTENZIONE: ALTA TENSIONE, NON TOCCARE
CUIDADO: ALTA-TENSÃO, EVITE CONTATO
LET OP: HOOGSPANNING, NIET AANRAKEN
ADVARSEL: HØJSPÆNDING, UNDGÅ BERØRING
VARNING: HÖGSPÄNNING, RÖR EJ
ADVARSEL: HØYSPENNING, UNNGÅ KONTAKT
C053_0052BC_EG
Table of Contents
Preparation ..............................................................................................................2
Installation Procedure .................................................................................2
Air Flow Specification ............................................................................................2
Physical Dimensions ...................................................................................2
Thermal Vent Kit Parts ...........................................................................................3
Parts ............................................................................................................3
Installation ..............................................................................................................4
Thermal Vent Kit ........................................................................................4
Process ECS ............................................................................................................5

4/29/05 INSTALLATION INSTRUCTIONS for the THERMAL VENT KIT 1


Preparation

Preparation
Installation Procedure
The SOCKET-OUTLET shall be installed near the equipment and shall be easily
accessible.

Air Flow Specification

Do not connect the equipment to the WALL OUTLET before the


configuration is completed

Air Flow 420 - 450 CFM (Cubic Feet/Minute)


Exhausted BTU/Hour Approximately 17,000 BTU/Hour (at full run) vented through an 8-in. HOSE.
Exhaust Hose Connection Connect the Exhaust Hose to a negative pressure source.
Diameter of Exhaust Hose 20.32 cm (8 in.)
Exhaust Hose Length 3.04 m (10 ft.)

Physical Dimensions
Width 61 cm (24 in.)
Depth 35.5 cm (14 in.)
Height: 56 cm (22 in.)

2 INSTALLATION INSTRUCTIONS for the THERMAL VENT KIT 4/29/05


Thermal Vent Kit Parts

Thermal Vent Kit Parts


Parts
 FRU No. Description Quantity
D3404 Vent Kit Ay 1
D3405 Process ECS Plate 1
D3406 Paper Supply ECS Plate 1
D3407 8-Inch Exhaust Hose, 10 ft. 1
G1114 Screw - Mach, 8-32 X 3/8, Torx 6
G3100 Nut - Keps, No. 8 - 32 6

D3406
G3100

D3407

G1114

D3405

D3404
C053_1031DCA D3402 D3403
C053_1031DC

4/29/05 INSTALLATION INSTRUCTIONS for the THERMAL VENT KIT 3


Installation

Installation
Thermal Vent Kit

Paper Supply ECS

WARNING
Communication Lines Must
Be Disconnected BEFORE
You Service This Equipment.

<01-009> C053_0053AC

1. Remove the 4 SCREWS and the EXHAUST PLATE.


2. Use the 6 SCREWS and 6 NUTS to install the PLATE to the EXHAUST PLATE
3. Install the EXHAUST PLATE into the PAPER SUPPLY ECS DOOR

It may be necessary to use the 6 NUTS G3100 with the 6 SCREWS G1114.

PLATE

PAPER SUPPLY
ECS DOOR

G1114
6 SCREWS

4 SCREWS

EXHAUST
C053_0243HCA
C053_0243HA
PLATE

4 INSTALLATION INSTRUCTIONS for the THERMAL VENT KIT 4/29/05


Process ECS

Process ECS
1. Remove the 4 SCREWS and the EXISTING EXHAUST PLATE from the PRO-
CESS ECS DOOR.
2. Use the 2 SCREWS to install the new EXHAUST PLATE into the PROCESS ECS
AY.
a. Remove the FILTER HOLDER D3109.
b. Disconnect:
–CONNECTOR D3121J1
–CONNECTOR D3122P2
c. Loosen the 4 SCREWS and remove the ECS BLOWER HOUSING AY D3127
d. Remove the CABLE TIE to provide access to the HARNESS D3217J4
e. Use a CABLE TIE to hold the remaining HARNESSES onto the TIE MOUNT.
f. Install the CONNNECTOR D3217J4 into the cut-out of the FRAME.
g. Install the ECS BLOWER HOUSING AY and tighten the 4 SCREWS.
h. Connect:
–CONNECTOR D3122P2
–CONNECTOR D3121J1
i. Install the FILTER HOLDER.

4/29/05 INSTALLATION INSTRUCTIONS for the THERMAL VENT KIT 5


3. Move the FAN AY portion of the THERMAL VENT KIT into the opening of the
PROCESS ECS AY.
4. Use the CASTORS to level the FAN AY.
5. Install the CONNECTOR D3402P1for the FAN AY to CONNECTOR D3217J4.
6. Install the 2 SCREWS to fasten the FAN AY in position.
7. Install the EXHAUST HOSE.

2 SCREWS

NEW EXHAUST
PROCESS PLATE
ECS AY
D3217J4
CONNECTOR EXHAUST
HOSE
FAN AY

4 SCREWS

CASTOR

OLD
EXHAUST D3402P1
PLATE CONNECTOR
C053_0244HCA
C053_0244HA
2 SCREWS
Printing Safety-Relevant and Customer Documentation

Printing Safety-Relevant and Customer Documentation


IMPORTANT: It is a safety regulation that all safety-relevant documents be
printed in both English and the appropriate local language for the customer.

Print the following documentation and leave it with the customer:


• Safety Information for Digital Production Systems (A14M96)
• Digital production system User Guide (W821)

4/29/05 7
Eastman Kodak Company
2600 Manitou Road
Rochester, New York 14653
USA

© Kodak 2008. All rights reserved.


TM: Kodak, NexPress, and NexPert

To learn more about solutions from Kodak, visit graphics.kodak.com

Subject to technical change without notice.

You might also like