ADEC Presentation - Motivline
ADEC Presentation - Motivline
Agenda
           1. Training Schedule
2. Motivline® System
Page 2 |
           Training Schedule
                   9:00 – 10:30   Class
                  10:30 – 10:45   Break
                  10:45 – 12:00   Class
                  12:00 – 1:00    Lunch
                   1:00 – 2:30    Class
                   2:30 – 2:45    Break
                   2:45 – 5:00    Class
Page 3 |
                        The Motivline® System
             Engines                 Applications
Page 4 |
           The Motivline® System
Page 5 |
                   The Motivline® System
Page 6 |
                                The Motivline® System
                                              ECU 7 Overview
LED (red)                                                                 Plug X1
- OFF (No Power Supply)
- ON (Normal Operation)                                        System Cable / Connection to Plant
- Flashing slow (Incorrect Data Set /MPS, APS)                               Side
- Flashing fast (Internal Error, e.g. defective RAM)             (CAN, A-IN/OUT, BIN-IN/OUT)
                                                                          Plug X2
                                                                          Sensor Harness
                                                               (e.g. Pressure, Temp., Speed Sensors,
                                                                        High Pressure Pump)
                                                                          Plug X3
                                                                         Power Supply
                                                                 (Main/Emergency Power Supply,
                                                                           Ignition)
                                                                             Plug X4
                                                                           Injector Harness
Page 7 |
                                  The Motivline® System
                                          ECU 7 DILA
The Diagnostic LAMP (DILA) signals the following codes:
            Time                  0 Sec   1 Sec   2 Sec   3 Sec   4 Sec
Normal Operation
No Firmware available
Application crashed
Page 8 |
                    The Motivline® System
                  ECU-7 Technical Information
Torque based engine management system
Contains 20 injector drivers
Supports:
Common Rail Injection
     Supports Pre, Post and Main Injection Strategies
     Only Main Injection is used
     42V Injection control - speeds up injector response time
PLD - Pump Line Düsenöffnung (Nozzle) Injection
Gas Injection
Allows for improved engine emission strategies and reduced fuel consumption
Page 9 |
                    The Motivline® System
               ECU-7 Technical Specifications
Steady state case temperature                     -40 to +75°C
Cyclic state case temperature                     -40 to 105°C
Vibration Rating                                  max 3.6 grms
Page 10 |
            The Motivline® System
              ECU 7 Input Channels
Page 11 |
             The Motivline® System
               ECU 7 Output Channels
Page 12 |
                   The Motivline® System
            ECU 7 Standard X4 Plant Channel Assignments
Page 13 |
                   The Motivline® System
            ECU 7 Standard X4 Plant Channel Assignments
Page 14 |
                The Motivline® System
        ECU 7 Standard X3 Engine Channel Assignments
Page 15 |
                The Motivline® System
        ECU 7 Standard X3 Engine Channel Assignments
Page 16 |
               The Motivline® System
                       ECU 7 X3 IGI Input
                                          Ignition Input
Disrupting IGI Triggers E –Stop Counter
                                      +
                                                     IGI
No data loss at emergency stop
                                                  ECU 7 power up
                                                  Ignition on = 24V
Page 17 |
                The Motivline® System
        ECU 7 Standard X2 Engine Channel Assignments
Page 18 |
                The Motivline® System
        ECU 7 Standard X2 Engine Channel Assignments
Page 19 |
                The Motivline® System
        ECU 7 Standard X2 Engine Channel Assignments
Page 20 |
                The Motivline® System
        ECU 7 Standard X2 Engine Channel Assignments
Page 21 |
                   The Motivline® System
            ECU 7 Standard X1 Plant Channel Assignments
Page 22 |
                   The Motivline® System
            ECU 7 Standard X1 Plant Channel Assignments
Page 23 |
                             The Motivline® System
                 SAM Standard Isolated Binary Inputs
B_IN
 B_IN11       Auxilary
               AuxilaryEngine
                        EngineProtection
                               Protection B_IN
                                           B_IN11
                                                11   Spare
                                                      Spare
B_IN
 B_IN22       Binary
               BinaryOutput
                      OutputTest          B_IN
                             Test          B_IN12
                                                12   Neutral
                                                      NeutralSaftey
                                                              SafteySwitch
                                                                     Switch
B_IN
 B_IN33       Test
               TestOver
                    Overspeed             B_IN
                         speed             B_IN13
                                                13   P-Diff.
                                                      P-Diff.Fuel
                                                              FuelPrefilter
                                                                   Prefilter
B_IN
 B_IN44       Reset
               ResetTrip
                      TripData           B_IN
                           Data           B_IN14
                                               14    Spare
                                                      Spare
B_IN
 B_IN55       Start
               StartInterlock
                     Interlock           B_IN
                                          B_IN15
                                               15    Spare
                                                      Spare                       Binary Input
B_IN
 B_IN66       Park
               ParkBreak
                    BreakInterlock
                          Interlock      B_IN
                                          B_IN16
                                               16    Disable
                                                      DisableHalf
                                                              HalfEngine
                                                                   Engine
B_IN
                                                                                  +24V switch
 B_IN77       Preheating
               PreheatingON
                          ON             B_IN
                                          B_IN17
                                               17    Spare
                                                      Spare
B_IN
 B_IN88       Burn
               BurnPreheating
                    PreheatingON
                               ON        B_IN                                  Each input uses an
B_IN                                      B_IN18
                                               18    Spare
                                                      Spare
 B_IN99       Spare
               Spare                                                              Optocoupler
                                         B_IN
                                          B_IN19
                                               19    Rating
                                                      RatingSwitch
                                                             Switch11
B_IN
 B_IN10
      10      Alarm
               AlarmReset
                     Reset
                                         B_IN
                                          B_IN20
                                               20    Rating
                                                      RatingSwitch
                                                             Switch22              >12V = ON
                                                                                   <9V = OFF
  Page 24 |
                        The Motivline® System
            SAM Standard Non-Isolated Binary Inputs
            P_IN
            P_IN11   Stop
                     StopButton
                          Button
            P_IN
            P_IN22   Disable
                     DisablePreheat
                             Preheat
            P_IN
            P_IN33   Start
                     StartButton
                           Button          Binary Input
            P_IN
            P_IN44   Spare
                     Spare                 +24V switch
            P_IN
            P_IN55   Spare
                     Spare
                                          No Isolation
            P_IN
            P_IN66   Manual
                     ManualFan
                            Fan11&&22ON
                                     ON
            P_IN
            P_IN77   Crank-No-Start
                      Crank-No-Start      >10V = CLOSED
Page 25 |
                      The Motivline® System
                  SAM Standard Voltage Outputs
                                V_OUT
                                V_OUT11   Engine
                                          EngineSpeed
                                                  Speed
                                V_OUT
                                V_OUT22   Coolant
                                          CoolantTemperature
                                                   Temperature
                                V_OUT
                                V_OUT33   Fan
                                           Fan11Demand
                                                DemandFeedback
                                                         Feedback
            Instrument Output
            U_Out = 0 – 10 V    V_OUT
                                V_OUT44   Lube
                                           LubeOil
                                                OilPressure
                                                   Pressure
                                V_OUT
                                V_OUT55   Spare
                                          Spare
              Scalable via
                DiaSys          V_OUT
                                V_OUT66   Spare
                                          Spare
                                V_OUT
                                V_OUT77   Fan
                                           Fan11Control
                                                Control
                                V_OUT
                                V_OUT88   Fan
                                           Fan22Control
                                                Control
Page 26 |
                      The Motivline® System
                   SAM Standard Analog Inputs
            A_IN1
            A_IN1 TT––Exhaust
                      ExhaustAABank
                               Bank
            A_IN2
            A_IN2 TT––Exhaust
                      ExhaustBBBank
                               Bank
            A_IN3
            A_IN3 Pressure
                   Pressure11
            A_IN4
            A_IN4 Pressure
                  Pressure22
            A_IN5
            A_IN5 P-Differential
                   P-DifferentialFuel
                                  FuelPrefilter
                                       Prefilter    Analog Inputs
            A_IN6
            A_IN6 Air
                  AirFilter
                      FilterRestriction
                            Restriction               0V – 10V
            A_IN7
            A_IN7 Fuel
                   FuelFilter
                        FilterRestriction
                              Restriction              0V – 5V
            A_IN8
            A_IN8 Auxilary
                   AuxilaryEngine
                             EngineProtection
                                     Protection       4 – 20mA
                                                   PT 100 / PT 1000
Page 27 |
                       The Motivline® System
            SAM Standard Binary Transistor Outputs
                                                           BT_OUT
                                                            BT_OUT10
                                                                   10 Preheat
                                                                       PreheatStatus
                                                                               Status
                          BT_OUT
                           BT_OUT11 Torque
                                     TorqueLimit
                                            Limit          BT_OUT
                                                            BT_OUT11
                                                                   11 T-Coolant
                                                                       T-CoolantAlarm
                                                                                 Alarm
                          BT_OUT
                           BT_OUT22 Speed
                                     SpeedWindow
                                           Window11        BT_OUT
                                                            BT_OUT12
                                                                   12 T-Charge
                                                                       T-ChargeAir
                                                                                AirAlarm
                                                                                    Alarm
                          BT_OUT
                           BT_OUT33 Speed
                                     SpeedWindow
                                           Window22        BT_OUT
                                                            BT_OUT13
                                                                   13 P-Coolant
                                                                       P-CoolantAlarm
                                                                                 Alarm
                          BT_OUT
                           BT_OUT44 Preheat
                                     PreheatON
                                             ON            BT_OUT
                                                            BT_OUT14
                                                                   14 P-Lube
                                                                       P-LubeOil
                                                                              OilAlarm
                                                                                  Alarm
                          BT_OUT
                           BT_OUT55 LO
                                     LOPreheat
                                         PreheatMode
                                                 ModeON
                                                      ON
   Binary Transistor                                       BT_OUT
                                                            BT_OUT15
                                                                   15 P-Crankcase
                                                                       P-CrankcaseAlarm
                                                                                    Alarm
                          BT_OUT
                           BT_OUT66 HI
                                     HIPreheat
                                        PreheatMode
                                                ModeON
                                                     ON
            Outputs                                       BT_OUT
                                                           BT_OUT16
                                                                  16 Override
                                                                      OverrideActive
                                                                                Active
                          BT_OUT 7   Spare
                           BT_OUT 7 Spare
  + 24 Volt Switched                                      BT_OUT
                                                           BT_OUT17
                                                                  17 Shutter
                                                                      Shutter11
                          BT_OUT 8   Overspeed  Alarm
                           BT_OUT 8 Overspeed Alarm       BT_OUT
                                                           BT_OUT18
                                                                  18 Shutter
                                                                      Shutter22
                          BT_OUT 9   Ready For Start Lamp
                           BT_OUT 9 Ready For Start Lamp BT_OUT 19 Engine Stop from
                          BT_OUT                           BT_OUT 19 Engine Stop from
                           BT_OUT10
                                  10 Preheat
                                      PreheatStatus
                                              StatusLamp
                                                     Lamp            Prot
                                                                      ProtMod.
                                                                           Mod.
                                                           BT_OUT
                                                            BT_OUT20
                                                                   20 Spare
                                                                       Spare
Page 28 |
                      The Motivline® System
            SAM Standard Binary Relay Outputs
                                 BR_OUT
                                 BR_OUT11 HT/LT
                                           HT/LTValve
                                                 ValveAfter
                                                       AfterFilter
                                                             Filter
                                 BR_OUT
                                 BR_OUT22 HT/LT
                                           HT/LTValve
                                                 ValveBefor
                                                       BeforFilter
                                                             Filter
              Binary Relay
                 Outputs         BR_OUT
                                 BR_OUT33 Preheat
                                           PreheatUnit
                                                  UnitON
                                                       ONValve
                                                           Valve
            + 24 Volt Switched   BR_OUT
                                 BR_OUT44 Spare
                                           Spare
Page 29 |
                      The Motivline® System
                   SAM Standard PWM Outputs
Page 30 |
              The Motivline® System
            SAM Standard Frequency Inputs
                  F_IN
                   F_IN11   Spare
                            Spare
                                    Frequency Input
                  F_IN
                   F_IN22   Spare
                            Spare
                                       5…500HZ
Page 31 |
            The Motivline® System
               Wiring Diagrams
Page 32 |
            The Motivline® System
               Plant.txt & OV List
Page 33 |
               The Motivline® System
                     SAM Monitoring
  Remote Diagnostic and Monitoring capabilities
 Page 34 |
             The Motivline® System
                SAM Ethernet Interface
                                                       Remote Location
                                                          Ethernet
                                   Telephone
                                      telephone   Router         Webpage
                                   Network or      Router         DiaSys
                                       network
                                   Internet
                                      Router
                                       Router
                        Ethernet
SAM
Page 35 |
            The Motivline® System
             SAM Webpage Feature
Page 36 |
                 The Motivline® System
                      SAM Life Data Function
Engine Life Data is
backed up on CF card                                     SAM
                            Backup Engine life data
Engine Hours
Load Profile
Fuel Consumption           Engine life data:         ADEC
                            • engine hours
Etc.                       • error log
                            • load profile
Page 37 |
               The Motivline® System
            SAM Field Data Handling Function
Process:
Page 38 |
            The Motivline® System
               SAM Replacement
Page 39 |
            The Motivline® System
                   Options
Page 40 |
                  The Motivline® System
                     Customer CAN Options
               CAN Connection Board CCB 2-03
                     Translates PCS/MCS 5 Bus to:
                                   J1939
                                  CAN Open
Page 41 |
                         The Motivline® System
                                 POM Option
Starter wiring left
Starter fuse
                                     Diagnostic lamp
                                                Not connected to PCS 5 Bus
                       Battery
                                               Own Bus similar to CAN Open
 Page 42 |
                The Motivline® System
                        Self-Diagnostics
Page 43 |
            The Motivline® System
                EMU 7 Option
                     Engine Monitoring Unit
                     Expansion device for ECU 7
                     Node 3 for C&I
Page 44 |
                    The Motivline® System
                              EMU 7 Option
Sensor Monitoring
      • T – Main Bearings
      • T – Splash Oil
      • Lube oil pressure (redundant)
      • Individual Exhaust Temperatures
Page 45 |
               The Motivline® System
                  MTU DIS 10-02 Option
640 x 480
5.7“ Display
               Node 4 for C&I
Page 46 |
                  The Motivline® System
             MTU CARe Remote Diagnostics Option
Works with all Governors Via:
PCS/MCS 5
J1939
                                         User
                                e.g. Service personal
Webserver
 Page 47 |
                 The Motivline® System
            MTU CARe Remote Diagnostics Option
Page 48 |
Additional ADEC Options
                          Dialogue Options
                              X00E50204804
                                IDD - 101
                                             5295305612
                                              COB 9 - 01
            5295308112
            COB 14 - 01
Page 50 |
                  Display Options
                         Sturdy EDM
MTU PN X00017829/S0001
Uses J1939
Page 51 |
                         Display Options
                            Murphy PV 101
Provides Backlighting and LED alarm lights
Language options:
English, Spanish, French, German and Italian
 Page 52 |
                Display Options
            Murphy PV 101 Connections
Page 53 |
               Display Options
            Murphy PV 101 Dimensions
Page 54 |
                       Display Options
                          Murphy PV 750
TECHNICAL SPECS                                NOT YET RELEASED
Display: 7”/178mm color transmissive TFT LCD       Replaces PV 1000
Backlighting: LED, 400-500 cd/mC
SD storage (optional)for:
Program updates, map and diagnostic data storage
CAN: 3 CAN ports according to CAN spec. 2.0B
Protocols Supported:
    • J1939
    • NMEA 2000 (GPS)
    • CANopen
    • Free Form CAN
 Page 55 |
             Display Options
            Murphy Gauge Options
Page 56 |
                           Display Options
                        Murphy Gauge Options
Page 57 |
                         RS485 Slave from PV 101 or 750
                              Display Options
                           Murphy Gauge Options
0-3000RPM
Page 59 |
            Display Options
            VDO Gauge Options
Page 60 |
            Display Options
            VDO Gauge Options
Page 61 |
            Display Options
            VDO Gauge Options
Temperature 0 – 120 C
Diameter=52mm
4-20mA
Page 62 |
            Display Options
            VDO Gauge Options
Page 63 |
                   Hardware / Software Kit
Page 65 |
            Interface Cable
Page 66 |
            DiaSys, Hardware Key and Translator
Page 67 |
            USB to RS232 Adapter
Page 68 |
                   Dongle Levels and Access
• Level 0                                  • Level 1b
Allows for viewing parameters and          Allows for viewing parameters and
selecting basic functions                  making major changes.
Level 0 is designed for final              Level 1b is designed for Service
customers                                  Engineers and Service Technicians
• Level 1a                                 • Level 1c
Allows for viewing parameters and          Allows for viewing parameters and
making minor changes                       making specific changes
Level 1a is designed for OEMs              Level 1b is designed for the Test
                                           Bench
                                 • Level 2 and 2+
            Allows for changing all parameters including EPA relavant
                Level 2 is designed for Development Engineers
Page 69 |       Level 2+ is designed for Development Engineers
            Thank You!
Page 70 |