Owner's Manual Ver. 1.

1 / October 2018

© Mytek 2018

For news, driver updates, technical support, tips and further product
information please visit our website:
mytekdigital.com

Technical support issues are handled via our online support ticketing
system. Please enter details of the ticket in the support/download
section on Mytek website.

148 India St.


Brooklyn, NY 11222

tel. +1 (347) 384-2687


User’s Manual 3

Contents
1. Introduction............................................................................................4

2. Package Content......................................................................................4

3. Features..................................................................................................4

4. Before You Begin.....................................................................................4

5. Quick Start..............................................................................................5

6. Card Instalation.......................................................................................5

7. Connecting Clock Signal Line...................................................................8


7.1 Single Converter................................................................................8
8. Master 8x192 ADDA converter front panel...............................................8

9. Input Connection.....................................................................................8

10. Signal Routing.......................................................................................8

11. Windows installation and configuration.................................................9


11.1 Windows – USB 2.0 driver installation..................................................9
11.2 Windows – Mytek Control Panel installation process............................. 10
12. USB2 CLASS2 DIO CARD OSX installation............................................. 11
12.1 OSX – USB 2.0 driver installation...................................................... 11
12.2 OSX – Mytek Control Panel installation............................................... 11
13. Firmware update Windows and OS X.................................................... 12

14. Mainboard firmware update................................................................. 13

15. Specifications....................................................................................... 14
4 Mytek USB2 Class2

1. Introduction
The Mytek USB2 CLASS2 Card is an optional card that is installed into the rear expansion slots of
the Mytek 8X192 ADDA converter. With this card installed the Mytek 8X192 ADDA can be directly
connected to a MAC OS, Linux or Windows computer via USB. The card may be installed by the user
as described further in the manual.

All the best,


The Mytek Digital Team

2. Package Content
• The USB2 CLASS2 expansion card

• EEPROM chip for 8x192 mainboard

3. Features
The extension card offers option of connecting 8x192 ADDA via the USB interface and using this
converter as the audio interface for Windows, Linux and Mac OS.

4. Before You Begin


Before connecting the USB2 CLASS2 card please check if the most current firmware (version 6.3 or
later) is installed in the 8X192 converter. To verify the version, locate the firmware chip (8 pin DIP chip
in a socket near the aluminum heat sink) on the main converter board or contact Mytek if you require
assistance.

In the support section of the Mytek website at: www.mytekdigital.com/download_library you will find
current detailed information about firmware versions and most current firmware and driver update
instructions. If necessary contact Mytek and request appropriate firmware.
User’s Manual 5

5. Quick Start

Remember to turn off and disconnect power and to disconnect


signal cables while working with the top cover removed.

1. Installation of USB2 CLASS2 card


Remove the top cover from the converter, unscrew the DIOCARD1 or DIOCARD2 slot plate
and install the USB card using the existing screws in either slot. If there is a Protools DIO card
installed it will work in slot 1 only. All other DIO cards including USB will work in either slot.
The card must be installed with the components facing up. Double check that all connector pins
match up with the pins of the connector on the main converter board properly. Pin mismatch
may damage the card or converter. Follow detailed installation instructions further below.

2. Driver Installation
Drivers should be installed before the first connection of the converter to the computer. Most
current drivers are available in the download library at www.mytekdigital.com.

3. Connecting the card to the computer


Turn off the ADDA 8x192 converter before plugging in the USB cable. The computer can be left
turned on. After making the connections, the converter can be powered on.

4. Configuration
On first power up of the converters, each converter should be recognized by the computer and
have the driver installed automatically. Further configuration of inputs and outputs is done in
your DAW software.

6. Card Instalation
The DIO USB2 CLASS2 card can be installed in either the DIOCARD1 or DIOCARD2 slot. The card can
be installed together with any other card available for the 8x192 converter. If Protools DIO card is
installed it will work in slot 1 only. All other DIO cards including USB2 CLASS2 will work in either slot.

Before installing the card, check if the converter’s


firmware supports DIO USB2 CLASS2 card (version 6.3 or
later). If not, contact Mytek and request current version.

DIO CARD #2 DIO CARD #1

8x192 ADDA converter rear panel


6 Mytek USB2 Class2

WARNING!
Remember to follow basic safety rules on electronic device handling while opening
the converter:
• Keep your hands dry,
• If floor is carpeted ground spray surroundings with water mist and ground
your wrist to the chassis before unpacking and handling the DIO card.
• Turn off power and detach power and signal cables while working with the top
cover removed.

To install the USB card:


1.Check if the power cord and all signal and clock 4.Unscrew the cover plate of the selected slot on
lines are disconnected. the rear panel.
2. Remove the top cover.

5. Partially insert the card from the back of


3. Locate the DIOCARD1 or DIOCARD2 expansion converter.
slot on the mainboard.
User’s Manual 7

6. Connect the card ribbon cable to the elected After boot up (which takes approx 20 sec) the
slot connector on the mainboard. Double check converter will switch to regular mode, and USB
all pin alignment. Card (DIOCARD1 or DIOCARD2) can now be
selected as signal source for DAC. Typically
“analog” would be selected as ADC source (see
converter manual).

7.Gently push the card inside and secure it with


four screws

8.Attach converter top cover.

9.Connect power and signal lines.

10.Turn the converter on.


8 Mytek USB2 Class2

7. Connecting Clock Signal Line


7.1 Single Converter
If a single converter is used in the system, using it’s internal clock will provide the best performance
(regardless of what a clock dealer will tell you.) If external clock is used for systemic reasons SAMPLE
RATE must be set to EXT. by pressing and holding EXT CLOCK SOURCE switch.

Attention! In a system with multiple units, double check that the


configuration of clock signal lines, synchronization sources and
sampling frequencies of all converters in the system are correct.

8. Master 8x192 ADDA converter front panel

Check if the selected sampling frequency of the converter (FS) matches the sampling frequency in
Control Panel

Correct clock configuration is necessary for the proper operation of the converters and for the best
sound quality. Make the 1st Mytek in the chain the clock master for the whole studio. There is no
benefit of using a dedicated clock. Clocking off the Mytek’s internal clock generator produces superior
results because the clock and the clock line current drivers are the best in the industry.

Changing external synchronization source while the program is running may result in improper
operation of converters and loud cracks in the analog section.

9. Input Connection
There s one USB port on USB card which should be used for computer connection.

10. Signal Routing


ADDA8x192 converter provides the system with 8 input and 8 output channels. If more than two
channels are used, audio software which understands multichannel I/O must be used.
User’s Manual 9

11. Windows installation and configuration


Note that for proper operation it is necessary to install the USB2 driver (Windows only) and Mytek
Control application. Both these have separate installers.

11.1 Windows – USB 2.0 driver installation


To simplify installation it is recommended to first install the drivers before the unit is connected to the
computer. The latest drivers are available at mytekdigital.com

1. Locate the MytekUSB2Drv.v4.xx.x.zip file 5. Setup.exe will now install the Mytek Driver.This
and extract the contents of the archive by right process may take a few minutes.
clicking on the zip archive icon and selecting
„Extract Here”.
6. Upon completion of „Setup.exe” press the
„Next” button.

2. Installation works automatically by a double-


click on MytekUSB2Drv.v4.xx.x.exe file.
3. Once the Setup.exe opens click „Next”.

7. To complete installation of the driver simply


click the „Finish” button.

4. Choose the location of installation.Default


location is „C:\Program Files\Mytek Digital\Mytek
USB 2.0 Driver”.We recommend leaving this as it
is.If you wish to customize the install choosethe
location by selecting browse. Click „Install”.

8. Connect the 8x192 ADDA to USB 2.0 port in


your computer.
10 Mytek USB2 Class2

11.2 Windows – Mytek Control Panel installation process


1. Locate the MytekControl.zip file and extract 4. To complete installation of the driver simply
the content by right clicking on the zip archive click the „Finish” button.
icon and selecting "Extract Here".

2. To install The Mytek Control double click the


extracted Windows Installer Package file. When
MytekControl Setup Wizard appears click „Next”
then accept license and click „Next” again. 5. Confirm installation by launching the
MytekControl application. Installation was
successful if the MytekControl application shows
the USB2 CLASS2 DIO CARD with serial number
and permits access to all options.

3. All options should be choosen in „Custom Setup”


menu. To confirm the installation of each option
select „Will be installed on local hard drive” then
click „Next” and „Install” to begin the installation.
User’s Manual 11

11.3 Windows – setting the USB2 CLASS2 DIO CARD as


playback device.
1. To set the USB2 CLASS2 DIO CARD as your 2. Right-click „Speakers USB2 CLASS2 DIO CARD”
default Windows playback device find the speaker and choose „Set as Default Device”.
icon (Sound Settings) in the notification area
(lower right corner of your screen) and right-
click. Choose "Playback devices" from the context
menu.
+

Note! – pro audio (DAW) applications (Cubase, Samplitude,


Reaper etc.) or proffesional media players (Jriver etc.) use ASIO
drivers and need to be configured different way. Please check
our „Software Setup Guide” shown on our web site:

mytekdigital.com

12. USB2 CLASS2 DIO CARD OSX installation


12.1 OSX – USB 2.0 driver installation
The USB2 CLASS2 DIO CARD custom designed USB2 controller supports driverless operation on
MAC. It means that no extra drivers are required. Driverless operation basically means „plug and
play”. The USB2 CLASS2 DIO CARD will automatically show up in your computer’s list of supported
audio devices as „USB2 CLASS2 DIO CARD”. Simply choose that as your default audio playback device
and the system will work.

12.2 OSX – Mytek Control Panel installation.

To install the Mytek Control Panel


simply drag and drop Mytek
application file (located in Mytek_
ControlPanel_v.1.xx.dmg file) to
„Applications” system folder. Follow
the link to downlad the latest
varsiion of the Mytek Control Panel
application.
12 Mytek USB2 Class2

13. Firmware update Windows and OS X

The current revision of the USB2


CARD2 DIO CARD firmware is shown
in the MytekControl „General” tab.

• The firmware can be updated by using USB2 port and Mytek Control Panel application. It requires
already installed USB2 driver (PC only) and Mytek Control Panel application. To download the
current firmware as well as drivers please visit mytekdigital.com
• It is recommended to turn off any powered speakers / power amps connected to the USB2
CLASS2 DIO CARD before proceeding with the firmware update.

Follow the steps below to update the firmware:


1. Download the latest firmware (*.mfb) file from mytekdigital.com
2. Click „Load firmware file” button and browse to the new firmware file then click „Open”.
3. Press the „Update” button to confirm uploading the firmware file to device's memory.
4. Confirm your choice by clicking „Yes” when warning dialog appears. A progress bar will indicate
when the flash process is finished.
5. When the update is finished the the CARD will reset and start in sleep mode. To switch it on press
the knob once. Once the CARD has been restarted the firmware update is complete. A reboot of
the computer is not necessary.

When the update fails:


1. Disconnect power cord.
2. Press and hold the BOOT MODE button and connect the power cord again.
3. The CARD runs in Bootloader mode. The 8x192 will not detect USB DIO Card
4. The update process should then be tried again.
5. To restore to standard mode turn the device off and on again.
User’s Manual 13

14. Mainboard firmware update


This update might be necessary to bring the converter’s main board up to date to allow its operation
with the firewire card.
Generally installed main board firmware should be of rev. 6.3 or greater. Contact Mytek via email to
obtain current firmware chip.

Remember to follow basic safety rules about handling of


electronic device while opening the converter: keep your hands
dry,remember to turn off power and disconnect power and signal
cables while working with the top cover removed
To perform firmware update of 8X192 ADDA 4. Gently remove old memory chip. To avoid
converter: damaging memory pins, remove the chip
1. Check if the power cord and signal and clock vertically. Retain old memory chip.
lines are disconnected.
2. Remove the top cover.

5. Carefully insert new memory chip in the


socket. The chip slot (pin1) should be matching
the socket slot ie must be facing back of the unit.
3. Locate the memory socket on the converter If necessary gently manually bend pins inward,
main board. to match the holes in the slot. During installation
check correct chip orientation.
14 Mytek USB2 Class2

6. Mount the top cover back.


15. Specifications
Technical Specification
DIGITAL
• Computer Audio I/O: USB 2.0, Audio Class
2, data stream up to 480Mb/s; 8 channels
in x 8 channels out, PCM up to 192kHz.

GENERAL
• Firmware: upgradable via Mytek Control
Panel, updates available online.

7.Attach power cord and other cabling.


8.Turn on the converter.

For about 2 seconds no LED should be lit on


the converter’s front panel, as new software is
copied from memory to the main board chips.
Then, all LEDs should turn on momentarily for
about 10-20sec, and subsequently the unit
should begin normal operation.
Check Mytek webpage for information on the
latest firmware versions.
www.mytekdigital.com
User’s Manual 15

Important Safety Information


• Read, keep and follow these instructions.
• Connect all your devices before powering the unit.
• Do not expose this device to moisture, rain and liquid of any kind.
• Clean only with dry cloth.
• If any form of liquid or a forin object enter the device switch it off and unplug it from the power
source. Do not operate device until the foreign object is removed or the liquid has completly
dried. If doubt please contact Mytek Digital.
• Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding-type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
• Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.
• Only use attachments/accessories specified by the manufacturer.
• When a cart is used, use caution when moving the cart/apparatus combination to avoid injury
from tip-over.
• Unplug this apparatus during lightning storms or when unused for long periods of time.
• Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
16 Mytek USB2 Class2

Warning
Excessive sound pressure from speakers and headphones can cause hearing loss. In order to use this
product safely, avoid prolonged listening at excessive sound pressure levels.
For the customers in the U.S.A.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved in this manual could void
your authority to operate this equipment.
All interface cables used to connect peripherals must be shielded in order to comply with the limits for
a digital device pursuant to Subpart B of Part 15 of FCC Rules.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This product with the CE marking complies with the EMC Directive issued by the Commission of the
European Community. Compliance with this directive implies conformity to the following European
standards:
• EN55103-1 : Electromagnetic Interference (Emission)
• EN55103-2 : Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following Electromagnetic Environments: E1 (residential),
E2 (commercial and light industrial), E3 (urban outdoors), E4 (controlled EMC environment, ex. TV
studio).

Information on Disposal for Users of Waste


Electrical & Electronic Equipment(private households).

The Wheelie Bin symbol on the products and/or accompanying documents


means that used electrical and electronic products should not be mixed
with general household waste. Disposing of this product correctly will help
save valuable resources and prevent any potential negative effects on
human health and the environment.
To properly dispose harmful substances and recycle the product, the
user is obliged to return it at the point of collection of electrical and
electronic equipment waste. For more information please contact your
local authorities, waste disposal units or retailer.

You might also like