152 RENR2696-03

Troubleshooting Section

g01308607
Illustration 90
Schematic for the fuel injection pump (70 pin MIC)

Test Step 1. Check the Battery Voltage Test Step 2. Inspect the Electrical
Connectors and Wiring
A. Measure no-load battery voltage at the battery
terminals.

Expected Result:

The battery voltage should be no less than 11.0 volts


for a 12 volt system.

The battery voltage should be no less than 22.0 volts


for a 24 volt system.

Results:

• OK – Proceed to Test Step 2.


g01312677
• Not OK – The battery voltage is below normal. Illustration 91
Pin locations on the 31 pin MIC
Repair: Recharge the batteries or replace the (3) Fuel pump power control
batteries. Use the electronic service tool to clear (4) Fuel pump battery -
any logged diagnostic codes and then verify that (8) Fuel pump battery +
the repairs have eliminated the fault.

STOP.