Life Safety System Specialists: Kentec Electronics LTD
Life Safety System Specialists: Kentec Electronics LTD
Life Safety
System
2014 - 2015 Specialists
Contents
Introduction 3 32 Sigma Matrix
Conventional Fire Alarm Mimic Display System
Taktis 6 36 Sigma XT
Analogue Addressable Control Equipment Extinguishant Control Panel
Syncro 20 50 Elite
Analogue Addressable 2-4 Loop Control Panels Analogue Add. Fire Control Panels & Repeaters UL/ FM Approved
For almost 30 years Kentec has evolved into one of the World’s leading At Kentec we believe that the quality of our products should be
life safety control system manufacturers. The Kentec name has become paramount; rigorous testing procedures are employed at every stage of
synonymous with World class products, great service and excellent the manufacturing process to ensure that all equipment is supplied to the
support. Based in the UK, Kentec is a truly global supplier, exporting highest standards. For this reason we are confident in offering an industry
control equipment to over 80 countries Worldwide, and in many different leading 3 years warranty on all product that we supply. We also understand
languages. that service is a key part of how a manufacturer’s quality is judged. To this
end we have invested extensively not only in our manufacturing facilities
At the heart of our success is our philosophy of in-house manufacturing but in our support team including technical support and training.
and investment. 2013 will see further investment in plant, machinery and
processes at our Dartford based facility. Our focus is on customer service As part of our customer care Kentec offers first rate technical support
and we pride ourselves on quick turnaround and our ability to react quickly facilities and a dedicated team of highly trained personnel provide direct
to customer requirements and market trends. telephone assistance; this is backed up by regular technical e-mail bulletins.
We also have a team of dedicated trainers who provide our customers with
Kentec offers the most comprehensive range of conventional, analogue product training both onsite or offsite, UK and overseas.
addressable fire detection and extinguishant control panels available. Our
custom build service is also highly regarded in the industry and utilises Kentec’s products are tested and approved to international standards such
our expertise in control panel technology to design and build high quality as EN54, EN12094, UL and FM.
product to exacting customer specifications. Marine products are now
an important part of our product portfolio. In 2013 we will be introducing Kentec achieved ‘Investors in people’ accreditation in 2004. Our
the all new “Taktis” product range. Taktis will become one of the most management systems are ISO 9001:2008 approved and our policy for
comprehensive and dynamic products within the industry with its focus on environmental awareness was officially recognized in 2007 when we
added value and advanced technology. gained our ISO 14001 certification from BSI. In 2008 Kentec was proud to
be awarded the Royal Warrant of Appointment by Her Majesty The Queen.
MANAGEMENT
SYSTEMS
Certificate No. FM 32987 Certificate No. EMS 518118 Certificate No.360 KM 73505
BS EN ISO 9001: 2008 BS EN ISO 14001:2004 BS EN ISO 9001:2008 KM 96761
3
18
Our In-house Facilities
4
Our printing department deploys state of the art digital
printing with the centre piece being our OCE Arizona
digital UV large format printer. The Arizona printer
has revolutionised the department offering increased
capacity, consistency and quality.
5
18
Taktis Analogue Addressable Control Equipment
6
Taktis Overview
Not only do the products and services offered under the Taktis brand provide Taktis “Bridge” Network Card (connect Taktis to your existing Syncro network)
solutions to the most technically challenging applications in life safety, Taktis will
deliver added value, market advantage and a competitive edge to your business. By taking advantage of the unique user interface it is possible to further customise the
control panel so it can meet specific alternative requirements such as local regional
The modular nature of the Taktis system allows all field wiring to be connected to variances, alternative additional functionality or corporate livery. Although this level
a passive mother board enabling addition, re-configuration or replacement of all of customisation is not generally a user feature, the architecture of the Taktis control
electronic hardware without the need to disconnect any field wiring. system makes customisation almost limitless.
This modularity also allows each panel to be customised with addressable loop
detection circuits, conventional detection circuits, relay cards, additional sounder
outputs or programmable I/O modules as required.
7
Taktis Fire Analogue Addressable Taktis Features
2-16 Loop Control Panels Compliant with EN54-2, EN54-4 and EN54-13
8
Taktis Overview Compatible Equipment & Extras
All panels are available with either a 5.25A, 24V power supply capable of charging up to 26Ah batteries
or a 10.25A, 24V power supply capable of charging up to 45Ah batteries. Taktis Fire can be supplied with
one of a range of remote power supply units making the control panel smaller and easier to install.
Up to 500 milliamps is available for each detection loop allowing for a generous quantity of loop powered
devices.
The four sounder circuits are each capable of supplying up to 2.5A at 24V to audio and audio visual
Selection of I/O boards
devices.
The addition of a Taktis Media Gateway communications device configured to report to the Virtual
Resource servers and subscription to one or more Virtual Resource browser based software modules,
allows systems to be managed remotely and from any location in a simple and efficient manner.
Taktis Media Gateway also provides the interface between control systems and other products
and utilities such as PC graphics, Voyage Data Recorder and a growing number of third party Taktis
compatible products.
Configurable serial ports will allow connection to BMS systems using LonWorks, Modbus or BACnet
protocols. VR Taktis Media Gateway
Taktis fire systems are scalable with Taktis Net Enhanced High Speed Networking. This allows up to
128 panels to be connected together as a fully fault tolerant networked system with rapid inter panel
communications and up to 1.2km of standard two core fire resistant cabling between nodes.
Each panel can be configured to display all or any events from any other panel allowing master/slave,
multiple master/slave or peer to peer configuration.
Sophisticated network analysis tools provide the ability to identify connection problems instantly and the
commissioning mode allows individual panels to be prevented from transmitting events to the network
while maintaining communications.
Taktis Network Card
Adding a Taktis “Bridge” Network Card to your Taktis Panel or Taktis Network provides an interface
between existing Syncro and Taktis Control Systems providing backward compatibility and a unique
upgrade path.
Connections Via:
Configurable functionality
Configurable languages
10
Taktis Vision Overview Compatible Equipment & Extras
Based on an all new hardware and software platform, the large, full colour graphical display with touch
screen functionality, delivers information on the status of the fire alarm system to single or multiple
locations.
Taktis Vision repeaters can be configured to offer full display and control to replicate the functionality of
the fire control panel or to operate as a simple, display only device for applications where access to control
the fire alarm system would be inappropriate.
Taktis Network Card
For other annunciation and control applications, Taktis Vision can be configured to provide customisable
switches and indications for a host of fire system ancillary functions.
Taktis Vision may be connected to the fire control panels’ fault tolerant, ancillary RS485 bus or to the fire
alarm panel fault tolerant network using standard, fire rated cable offering flexibility in system wiring.
Available in several standard formats, Taktis Vision can be mounted directly onto a wall, be recessed
using our quick-fix adaptor frame or fully flush mounted. Special enclosure finishes and colours are also
available to match existing decor.
11
Taktis Virtual Resource A Comprehensive Suite Taktis VR Features
of Software Based Tools Unique Life Safety management utility
More to come…
More VR applications will be added to the list providing users
with further enhancement to their value and revenue streams
12
Taktis VR Overview VR Vault
With Virtual Resource, Installers and Service providers are able to offer market leading Site details can be imported from VR Access or added and set up manually to create
functionality through remote management and provide improved service at lower cost and customer records.
greater efficiency.
Service frequency and device activation list schedules can be set and resources allocated
The remote management features offered by Virtual Resource can result in reduced fault including, travelling time and estimated time to complete the service providing essential
call outs, improved servicing regimes, more effective maintenance, reduction of unwanted data for planning service engineer’s activities. Service engineers can view and print their
alarms and improved overall service to the end user. work schedules including site specific notes and previous service records directly from the
system if required.
Whether you are a Service provider, building owner or facilities manager, change the way
you think about managing your Fire Detection System. Taktis VR you can reduce costs, add VR Print
value and improve service integrity by employing the latest communication and analytical
technologies. Designed to replace panel mounted printers which are inherently difficult to manage and
provide very limited information. VR Print provides a secure method of storing and recalling
VR Access the control system events via any web browser. The user can simply view the systems
events on line, print PDF reports or download the data in formats such as csv for further
Gain access to data from all of your systems, assess performance, check status and make data analysis.
decisions based on facts, not assumptions.
VR Access allows a Virtual Resource enabled fire system to periodically report its status to
the secure servers and allows a VR Access subscriber to view the latest status report via
any web enabled device.
13
Taktis Configure Loop Explorer 2 (LE2) Taktis LE2 Features
Configuration Software Based on the industry leading Loop Explorer
Time manager
Group Manager
Powerful templates
Language support
14
Taktis LE2 Overview
Additional logical operators for NOT and TIME functions for use in cause and effects and
the inclusion of “groups” (collections of devices not necessarily in the same zone) increase
the power and flexibility of LE2 to far beyond what was achievable with its forerunner and
most other products currently on the market.
15
Taktis Network Diagram
High Integrity Configurable Network
Cloud Servers
GSM
IP Media Gateway
Dial-Up
Taktis Fire
2 - 8 Loop Analogue
Addressable Control Panel
24V DC
IO Cards
K772 K791 K792 K793
16 Channel 8 Way 8 Way Conventional 4 Way
I/O Board Relay Board Zone Board Sounder Board
RS485 bus
Taktis Fire
2 - 8 Loop Analogue
Addressable Control Panel
Taktis Vision
Up to 128 Panels/ Configurable Fire Alarm
Repeaters can be Repeater
added to the network.
Loop 1
Taktis Fire 240 devices (Argus Vega) or
2 - 16 Loop Analogue 127 devices (Hochiki).
Addressable Control Panel
17
18
Syncro AS Analogue Addressable Syncro AS Features
1-2 Loop Control Panels 16 zonal LED indicators
5 programmable inputs
3 programmable relays
3A power supply
18
Syncro AS Overview Compatible Equipment & Extras
Syncro AS fully supports all devices from the leading, open protocol detector manufacturers and can be
supplied with Apollo (S90/XP95 /Discovery), Argus Vega or Hochiki ESP loop drivers, all capable of
providing up to 400 milliamps of loop current for the most demanding applications.
An integral 3 Amp power supply and temperature compensated battery charger provides ample power for the
two, 1 Amp rated standard sounder outputs, loop powered sounders and other devices.
Syncro AS is also available as a Lite version offering a very cost effective solution for smaller standalone
installations requiring only one detection loop.
Selection of I/O boards See website
The Lite version does not support the following:
Second loop, Printer output, Networking and connection of I/O boards or the View repeater.
Connectivity
Syncro AS connects seamlessly to other Syncro AS, or Syncro multi-loop panels and repeaters via the fully
fault tolerant and robust Syncro network. The Syncro AS supports all Syncro serial bus peripherals such as
View repeaters, 16 channel I/O boards, Relay boards, Sounder boards and Conventional Zone boards to
provide an additional 512, fully programmable points. 16 zonal LED indicators are provided as standard and the
panel will support up to 500 network wide software zones as per Syncro multi-loop panels.
OpenConnect BMS Communication Interface See DS66
Powerful Software
Programming, including powerful cause and effect functionality can be achieved using the intuitive Loop
Explorer configuration utility familiar to Syncro panel users. The new Loop Explorer 2 will also support all of
the Syncro AS product family.
The Guide graphics system or a modem for remote system interrogation by telephone lines may also be
connected to Syncro AS panels via the RS232 serial connection.
Ease of Installation
The elegant and simple construction of the panel enables the chassis to be completely dismantled by Syncro Net Network Card See DS23
removing just two screws. The outer cover can also be detached by removing two hinge pins making first
fix installation very simple and enabling the sensitive electronic parts to be stored safely for re-fitting at the
commissioning stage.
Housed in the same installer-friendly and attractively styled enclosure as the popular Sigma CP
(Conventional) and Sigma XT (extinguishant) range of fire control panels, Syncro AS combines compact and
practical styling with the programming power and connectivity normally associated with much larger systems.
19
Syncro Analogue Addressable Syncro Features
2-4 Loop Control Panels 2 or 4 loop versions as standard (for 6-8
loop versions see DS57)
Network up to 64 panels/repeaters
20
Syncro Overview Compatible Equipment & Extras
With proven and mature software at its heart, the Syncro range benefits from many years of development
and refinement to provide a fire alarm control panel range of outstanding robustness, versatility and flexibility.
Syncro multi-loop fire panels have a large clear display, context sensitive help screens, easy navigation
menus, versatile configuration options and simple controls all enhanced by the power and flexibility that
comes from compatibility with other components of the multi-loop Syncro system and peripherals.
Syncro fire panels fully support all devices from the leading, open protocol detector manufacturers and can
Syncro AS See Pg. 18/ DS47
be supplied with Apollo (S90/XP95 /Discovery), Argus Vega or Hochiki ESP loop drivers, all capable of
providing up to 400 milliamps of loop current for the most demanding applications.
An integral 5.25 Amp power supply and temperature compensated battery charger provides ample power for
The 4 standard sounder outputs, loop powered sounders and fully loaded loops of devices.
Connectivity
Syncro fire panels connect seamlessly to Syncro AS fire panels or other Syncro multi-loop panels and
repeaters via the fully fault tolerant and robust Syncro network. The network topology can be configured for
either a fully secure “loop” or as an “open ended” network for replacing older systems and using existing
cabling. Selection of I/O boards See website
The Syncro range supports a selection of serial bus peripherals such as View repeaters, 16 channel I/O
boards, Relay boards, Sounder boards and Conventional Zone boards to provide an additional 512, fully
programmable points. 0, 16, 48 or 96 zonal LED indicators can be provided as standard and the panel will
support up to 500 network wide software zones.
Powerful Software
The long established Loop Explorer configuration utility can be used to configure the Syncro range. With
the all new Loop Explorer 2 offering a simpler and more intuitive programming configuration tool capable of
realising the largest and most complex fire alarm systems with ease. OpenConnect BMS Communication Interface See DS66
The Guide graphics system or a modem for remote system interrogation by telephone lines may also be
connected to Syncro panels via the RS232 serial connection. All of the above combined with a host of
different language options (including those with Cyrillic characters) produce an outstanding and competitive,
world class fire alarm control panel range.
Ease of Installation
The elegant and simple construction of the Syncro panel range with full mechanical protection of all internal
electronics, ensures ease of installation and protection of the vital parts during installation.
Housed in installer-friendly and attractively styled enclosures, Syncro fire panels combine compact and
practical styling with powerful programming and connectivity to realise the largest of systems.
Syncro Net Network Card See DS23 21
Syncro Repeaters Analogue Addressable
Fire Control Panel Repeaters
Syncro View
Syncro Ident
22
Syncro Response Syncro Focus & Focus +
The 5 inbuilt programmable relays, I/O board serial bus and auxiliary 24V DC supply Primary indication is provided by the full graphic LCD with additional indications for
allow the Syncro Response repeater to provide additional system inputs and outputs power, fire, fault and disablement conditions provided by discrete LEDs.
to complement those provided by Syncro fire alarm control panels.
Controls are kept to a minimum with only two navigation buttons and a silence buzzer
Syncro Response repeaters can be provided with 0, 16, 48 or 96 zonal fire indicators button on the Syncro Focus and additional Silence Alarm, Reset and Re-sound alarm
and with an optional printer. A single 16 channel I/O card, 8 way relay card, 6 way buttons on the Focus+.
sounder card or 4 way conventional detection zone card can be fitted inside the
Syncro Response and a maximum of 32 I/O boards in total can be connected to the Ideal for additional building entrances, security desks or nurses stations this unit
serial I/O bus connection. provides an economical and more compact alternative to a full function, Syncro
Response repeater panel.
All Syncro Response repeaters are supplied with a Syncro network card pre-installed
for direct connection to a fault tolerant Syncro network. Syncro Focus connects directly to a fault tolerant Syncro network and can also be
used as a network booster to extend cable runs beyond the specified lengths as
required.
Ideal for locations where a control and indication point smaller than a full fire alarm Requiring only a low current 24V power supply and a 2 core data connection to
control panel is required, the Syncro VIEW is available in either a 24V DC powered the fire panel, Syncro Ident panels can be installed quickly and easily to provide
option (which can be powered via an additional 2 cores from the Syncro control panel supplementary information on the status of the fire alarm system with the minimum
auxiliary 24V DC supply) or a 230V powered option with local battery back up. of cost and effort.
23
Syncro Matrix Intelligent Fire Alarm Syncro Matrix Features
Mimic Display System Up to 504 LED’s can be controlled from any
Syncro or Syncro AS panel
24
Syncro Matrix Overview Enclosure Size Options
The Syncro Matrix system uses flexible, fibre optic light guides to illuminate areas on a floor plan, laid over
a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be
moved, removed or added on site without the need for any wiring.
185
303
Syncro Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power
on, Fire, Fault and Disablement and optional controls are for Alarm silence, Buzzer silence, Lamp test and
Reset.
M2 385mm W x 310mm H x 90mm D
Housed in attractive, slimline enclosures to match Syncro and Syncro AS fire alarm panels and with high
quality, full colour or monochrome floor plans, Syncro Matrix provide a clear, geographical indication of fire
alarm or other system activation enabling speedy identification of the source of an alarm or other event.
Configuration
The Syncro Matrix has a default configuration of zonal fire for the first 24 indicators but all indicators can 225
be configured to operate upon any event type and at point, zone or group level via Kentec’s powerful and 400
Indicators may also be configured to flash or illuminate steadily upon activation. This flexibility allows Syncro
Matrix mimics to be used for many other applications other than as a standard fire alarm indicator panel. S3 500mm W x 355mm H x 117mm D
Future Proofing
The Syncro Matrix is ideal for buildings such as hospitals where the building layout may evolve over a period
of time.
400
303
As the building changes, so too can Syncro Matrix, with very little cost or disruption. Modifying the mimic
is very straightforward and can be carried out on site without the need for any wiring or special tools. The
positions of the indicators can be freely moved anywhere on the grid and new indicators can be added using
kits of lenses and light pipes which are available. Additional mimic PCB’s are also available in kit form to
enable the capacity of the mimic to be increased as required.
M3 385mm W x 520mm H x 110mm D
Custom Solutions
Where the requirements of the installation exceed the standard range of Syncro Matrix panels, completely
515
bespoke solutions are available. 400
The enclosure size, mimic viewing area, colour and finish can all be tailored for the individual requirements of
the site, including the option of surface or flush construction.
Up to 32 mimic PCB’s can be connected to a single Syncro AS, Syncro or Syncro Response panel giving a
total of 504 LED’s that can be individually configured via the standard loop explorer configuration software.
To increase the flexibility of this product further, the LED extension boards are available in with yellow or green
indicators fitted.
S4 500mm W x 650mm H x 137mm D 25
Syncro Network Diagram Supports all
Syncro I/O
modules.
RS485
Up to 16 GUIDE An RS232 to RS485 The GUIDE dongle is fitted to Full function repeater
Repeaters may be data converter is the RS232 serial interface inside panels are loopless,
connected to a GUIDE supplied with the GUIDE the Syncro or Syncro Response they come with a choice of
system via a LAN (Local system. Panel. It converts data to RS485 and 0, 16, 48 or 96 zone
Area Network) must be fitted for the system to work. indicators.
K555
Network Card
Required
I/O
Syncro
Loop 1
Analogue Addressable
Control Panel
K555
I/O
Loop 1 Loop 2
Network Card
Required
(if fitted)
Syncro View
Local LCD Repeater
Syncro AS
Analogue Addressable RS232 24V DC or
Control Panel 230V AC
K556
Modem Card Syncro Ident
Programmable LED
The Syncro system is
compatible with Apollo,
Indication Panels
Argus Vega and Hochiki
protocols. Panels of any of
the above protocols can be 24V DC or
used on the same network. 230V AC
Syncro Focus +
Network LCD Repeater The Syncro network A mixture of up to 32
can be interrogated devices (including
remotely by using the K556 Syncro View, Ident and
modem module (normally Matrix) can be fitted to each
fitted inside panel) panel on the RS485 serial Syncro Matrix
connected via the telephone. interface. The maximum
number of Syncro View Fire Alarm Mimic
24V DC or panels on a single RS485 Display System
serial interface is 15.
230V AC
24V DC or 27
18
230V AC
Sigma CP Conventional Fire Alarm Control Panels Sigma CP Features
Fully certified to BS EN54-2 and BS EN54-4
Installer friendly
28
Sigma CP Overview Compatible Equipment & Extras
Sigma CP is available with two, four or eight detection zones in standard or installation saving, “two wire”
versions. The extensive range of configuration features available ensure suitability for new installations or
panel replacements on older systems.
Configuration options are stored in non-volatile memory and are easily accessed via an intuitive user interface
which allows the configuration data to be viewed and changed simply and easily.
Sigma CP control panels are compatible with most standard, conventional detectors, call points and
sounders and are also compatible with “two wire” detector bases from Apollo and Hochiki.
Sigma CP-R Repeater Panel See DS39
An integral three Amp power supply and temperature compensated battery charger provides ample power
for the two, 0.5 Amp rated standard sounder outputs, zonal sounder outputs on “two wire” versions and an
auxiliary 24V supply output.
Powerful Features
The simple and intuitive programming interface on Sigma CP panels allows simple configuration of many
parameters by entering simple codes which are listed on the inner door look up table and in the operation and
maintenance manual. Configurable options include sounder delays, short circuit triggering of zones, non-
latching zones, silent zones, I.S. barrier compatible zones and system disablements.
Sigma CP control panels have a dedicated; two wire serial bus for connection of repeater panels, Ancillary
relay boards or zonal sounder extension boards. Up to seven units may be connected to the serial bus which
can be up to 1200 metres in length. All units connected to the serial bus are fully monitored and the control
panel will announce a fault condition showing the address and type of any units that fail or are disconnected
after the panel has been configured to recognize them.
“Two wire” versions of Sigma CP can have detectors, call points and standard, polarized sounders connected
to the same two core cable, greatly reducing installation time and cost on some installations.
These “two wire” versions also provide the capability of zonal sounders which may be configured as zonal
alarm (sounders operate only in the zone of activation), common alarm (all sounders in all zones operate) or Sigma Sounder - Sounder Controller Units See DS48
two-stage alarm (sounders are continuous in the zone of activation and pulsing in all other zones).
Ease of Installation
The elegant and simple construction of the panel enables the chassis to be completely dismantled by
removing just two screws. The outer cover can also be detached by removing two hinge pins making first
fix installation very simple and enabling the sensitive electronic parts to be stored safely for re-fitting at the
commissioning stage.
Sigma CP panels combine compact and practical styling with the programming power and connectivity
required for the most complex and demanding conventional fire alarm system installations.
29
Sigma CP-A Conventional Fire Alarm Control Panels Sigma CP-A Features
AlarmSense Compatible 2-wire Fully compliant with BS EN54-2 and BS EN54-4
Installer friendly
30
Sigma CP-A Overview Compatible Equipment & Extras
The AlarmSense® system enables all detection and sounder devices in a given zone to be wired to the same
pair of cables thus greatly reducing the cabling and installation requirements and hence costs.
The AlarmSense® range of devices includes smoke and heat detectors, call points, base sounders, base
sounder/beacons and relay units – all wired to the same pair of cables.
Having sounders and sounder beacons installed on the same cabling as detectors and call points allows
all systems to be configured for common, zonal or two stage alarm by simply setting one of the panels
Sigma CP-R Repeater Panel See DS39
configuration options.
Selection of the AlarmSense® local alarm feature at sounder or sounder beacon bases invokes the
alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student
accommodation or nursing homes. When sounder or sounder beacon bases are selected for local alarm
mode, alarms are restricted such that only the sounder connected to the activated detector will operate
initially. The panel will attempt to reset the activated detector after a time delay and if successful no further
alarms are sounded. If the detector re-activates after being reset, a general alarm will sound throughout the
premises.
Activation of a second detector or a call point will sound the general alarm immediately.
Sigma CP Ancillary PCB See page 39
The alarm verification feature of the Sigma CP-A control panel greatly reduces the risk of unwanted alarms or
call outs while still providing secure, high quality fire protection throughout the premises.
All control panels have an integral, 3 Amp mains powered battery charger and power supply capable of
providing power to the most demanding of applications.
Ease of Installation
The elegant and simple construction of the panel enables the chassis to be completely dismantled by
removing just two screws. The outer cover can also be detached by removing two hinge pins making first
fix installation very simple and enabling the sensitive electronic parts to be stored safely for re-fitting at the
commissioning stage. Sigma Sounder - Sounder Controller Units See DS48
31
Sigma Matrix Conventional Fire Alarm Sigma Matrix Features
Mimic Display System Up to 320 LED’s can be controlled
32
Sigma Matrix Overview Standard Enclosure Size Options
The Sigma Matrix system uses flexible, fibre optic light guides to illuminate areas on a floor plan, laid over
a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be
moved, removed or added on site without the need for any wiring.
185
303
Sigma Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power on,
Fire, Fault and Disablement and optional controls are for Alarm silence, Buzzer silence, Lamp test and Reset.
Housed in attractive, slimline enclosures to match and with high quality, full colour or monochrome floor
M2 385mm W x 310mm H x 90mm D
plans, Sigma Matrix provides a clear, geographical indication of fire alarm or other system activation enabling
speedy identification of the source of an alarm or other event.
Future Proofing
The Sigma Matrix is ideal for buildings such as hospitals where the building layout may evolve over a period
of time. 225
400
As the building changes, so too can Sigma Matrix, with very little cost or disruption. Modifying the mimic
is very straightforward and can be carried out on site without the need for any wiring or special tools. The
positions of the indicators can be freely moved anywhere on the grid and new indicators can be added using
kits of lenses and light pipes which are available. Additional mimic PCB’s are also available in kit form to S3 500mm W x 355mm H x 117mm D
enable the capacity of the mimic to be increased as required.
Custom Solutions
Where the requirements of the installation exceed the standard range of Sigma Matrix panels, completely 400
303
bespoke solutions are available.
The enclosure size, mimic viewing area, colour and finish can all be tailored for the individual requirements of
the site, including the option of surface or flush construction.
515
400
Zone 2
230V AC
34
Conventional Fire Detection
Ancillary Board Ancillary Board
Sigma CP-R
Repeater Panel
230V AC
Sigma CP-R
Plant Controls Repeater Panel
Sigma Matrix
Fire Alarm Mimic
Display System
35
18
Sigma XT Extinguishant Control Panel Sigma XT Features
Approved to EN12094-1, EN54-2 and EN54-4
36
Sigma XT Overview Compatible Equipment & Extras
With three detection zones as standard, extinguishant release can be configured to activate from any
combination of detection zone inputs to allow (among other combinations) any two from three type
activations such as would be required for detection in ceiling void, room and floor void applications.
The extensive configuration options of the Sigma XT allow the functionality of the system to be extensively
modified while still complying with the requirements of the controlling standards for the equipment.
Sigma Si Status Units See DS41
The panel contains a large LED display to enable easy configuration and control which also displays the time
remaining until extinguishant release for added user safety.
The countdown timer is duplicated on up to seven remote status units to provide local indication of the
extinguishant system status. With all of the electronics mounted on a single, easily removable, steel plate
Sigma XT panels are both robust and easy to install.
Connectivity
To compliment the Sigma XT control panel there is a range of system status units.
Up to seven status units can be connected on a serial bus and require just two cores for data and two cores Sigma Si Hold Off Switch See DS41
for power. Once connected, status units are supervised and the Sigma XT control panel will indicate a fault
condition should any unit become disconnected.
Ease of Installation
The elegant and simple construction of the panel enables the chassis to be completely dismantled by
removing just two screws. The outer cover can also be detached by removing two hinge pins making first
fix installation very simple and enabling the sensitive electronic parts to be stored safely for re-fitting at the
commissioning stage.
37
Sigma XT+ Extinguishant Control Panel Sigma XT+ Features
Multi-Area Approved to EN12094-1, EN54-2 and EN54-4
2, 4 or 8 detection zones
1 to 4 extinguishant areas
38
Sigma XT+ Overview Compatible Equipment & Extras
The fire detection section connects to the extinguishant control modules via a serial link which allows secure,
bi-directional transfer of data between the two. Sigma XT+ modules may be mounted remotely in separate
enclosures and connected to Sigma CP panels via this serial interface to provide central fire detection and
control with distributed extinguishing systems.
Sigma XT+ modules may also be mounted separately from fire detection and control equipment and
activated by addressable output modules or volt free contacts from other systems via two monitored
activation inputs. Sigma Si Status Units See DS41
The fire detection part of the system has all of the benefits of the popular Sigma CP range with its many,
easily accessed configuration options and compatibility with a wide range of detection devices.
The Sigma XT+ extinguishing modules set a new benchmark for extinguishing control panels. Each module
is controlled by its own powerful microcontroller bringing unparalleled intelligence and versatility to multi area
extinguishing systems for the first time.
Sigma XT+ modules have inputs and outputs to cover all system requirements including individual, monitored
first and second stage alarms and dual extinguishing outputs. The extinguishing outputs can be configured
to operate together or as main and reserve for essential back up following a discharge. They can also be
individually calibrated to provide true open and short circuit monitoring through pyrotechnic actuators or a Sigma Si Hold Off Switch See DS41
wide range of solenoids.
Connectivity
In addition to Sigma XT+ extinguishing modules, up to seven Sigma CP ancillary boards providing zonal and
common relay outputs and seven Sigma CP sounder boards, each providing an additional eight, monitored
sounder circuits can be connected to the Sigma CP RS485 serial bus at up to 1200 metres from the control
equipment.
Also, up to seven Sigma XT ancillary boards and seven Sigma Si status units can be connected to each
Sigma XT+ module to provide remote status indication, control and additional outputs as required at up to
1200 metres from the control equipment. This flexibility ensures that any system configuration can be realised Sigma Si Ancillary PCB See DS75
with a minimum of cabling.
Ease of Installation
The simple construction of Sigma XT+ control panels utilises removable bridge plates for mounting all
electronic assemblies. These bridge plates bring the terminals to the front of the enclosure providing easy
access to all wiring terminals.
The outer door may be removed to further improve access by withdrawing the easily accessible hinge pins.
This ensures clear access for wiring and protection of the electronic assemblies during installation.
Multiple knockouts in the top, bottom and back and sides of the enclosures provide ample options for cable
entries. 39
Sigma Si Extinguishant Status & Ancillary Units
40
Sigma Si Features Sigma Si Overview Hold Off Overview
Detailed indication of the status of the control panel All models provide high brightness, LED indication of The unit has a durable, shrouded push button to
Manual Only, Automatic and Manual, Hold operated, prevent accidental operation and a simple 2 wire
Monitored data connection Disabled, Imminent and Released conditions. Models connection to Sigma XT, Sigma XT+ or Sigma Si
are also available with zonal fire indicators and a status units is required.
Countdown timer shows time remaining until release
common fault indicator.
Manual only and Automatic & Manual mode Sigma Si Hold off units are fitted with normally open
select keyswitch option For systems where local control of the Automatic/ and normally closed contacts to allow operation with
Manual mode and or a Manual extinguishant release monitored and unmonitored systems
Four wire connection (data and power) control are required, units are available with these
41
Syncro XT+ Extinguishant Control Panel Syncro XT+ Features
Multi-Area Addressable Complies with EN12094-1, EN54-2 and EN54-4
16 detection zones
ING
COM ON Up to 4 extinguishant areas
SO
Dual extinguishant outputs for each area
(configurable as Main/Reserve)
42
Syncro XT+ Overview Compatible Equipment & Extras
Up to 16 zones of addressable detection over 1 or 2 loops ensure every detector is able to contribute to
extinguishant release.
Up to 4 extinguishing areas and 2 releasing outputs per area can be controlled via simple coincidence
detection or via more complex cause and effects configured by the Loop Explorer configuration programme.
Syncro XT+ allows extinguishing systems to take full advantage of the more sophisticated detection
techniques provided by modern fire detectors as well as the other benefits of analogue addressable systems
Sigma Si Status Units See DS41
such as control of loop connected sounders, beacons and input/output modules.
With the addition of a Syncro network card, Syncro XT+ control panels can be networked to provide scalable
extinguishing systems for all sizes of installation.
Stand alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals
from remote fire detection control panels or addressable modules.
Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop
Explorer Configuration Programme.
All extinguishant areas may have up to 7, serially connected Sigma Si status indication and control units or
Syncro Si Status Units See DS79
ancillary relay boards connected via a simple 4 core cable.
43
Sigma XT Network Diagram
Manual Release
Door Interlock
Detection Zone 3
Detection Zone 2
Detection Zone 1
Sigma XT - EN12094-1
Approved Control Unit
44
Extinguishant System Control
Addressable
House Fire Alarm
4 Core
Hold Off Unit BMS
Interface
2 Core
2 Core
Door Interlock
45
18
PSU Power Supplies
46
K25000 Power supplies Overview Power Supply Units
Power Supplies
The K25000 range of 24V DC power supplies are designed to meet the exacting requirements of fire detection
and alarm systems and fire protection systems.
All models charge sealed lead acid batteries using sophisticated, temperature compensated charging and
monitoring techniques to keep the batteries in the best possible condition.
Over depletion of batteries is prevented by a low battery voltage disconnection function which removes the load
from the batteries when their terminal voltage reduces to a level which would damage them.
A low battery voltage fault warning is given when the batteries reach the minimum terminal voltage recommended
by the battery manufacturers.
A high series resistance in the battery supply circuit which would allow the power supply output voltage to fall S2014 - 2.5A PSU See DS19
outside of the specified range is indicated as a fault condition.
K25000 power supplies can be fitted with an optional dual output board to provide redundant power paths for fire
alarm applications and are available in a range of enclosures to accommodate different battery sizes.
Onboard LED indicators are provided to indicate the status of the unit and an onboard header is available to
extend status signals to other systems volt free relay contact that operates upon any fault condition or total
power failure.
Enclosures are designed to match both Sigma and Syncro fire panel ranges and are constructed from 1.2mm mild
steel and are finished with epoxy powder coating.
Unboxed or caged power supplies for incorporation into other equipment are available as follows:
47
Miscellaneous Items
Warning Signs Remote DocBox Audio Visual 1 Way Remote 4 Way Tamper Resistant
Indicator Unit Relay Board Indicator Unit Relay Board Vision Window
48
Warning Signs Relay Boards
Miscellaneous Items
Powered by a nominal 24V DC supply, the illuminated warning signs employ the very latest in Easy to fit and wire for additional control functions or to expand the capability of existing relay
LED technology to provide a high reliability, high brightness, audio/ visual warning indication unit to outputs, these simple boards contains either one or four 24V DC relays, which can be used for
supplement mandatory alarm warnings. any extra low voltage switching applications.
The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due Each relay has two changeover contacts, and an LED indicator to show when the coil is
to the unique “power boost” circuitry employed. This ensures that even with a system running on energised.
depleted batteries, all signs remain at full intensity.
The coils of the relays are commoned to the positive supply and the relays can be operated
A range of standard text signs are available and fully customised text and languages are easily individually by switching a negative to the numbered coil inputs.
accommodated. The large display panel is backlight with high intensity white LEDs to provide a high
The contacts are suitable for switching a maximum of 30V DC and 2 Amps. The current
contrast indication in a range of different colours.
consumption of the unit when operated from a 24V supply is approximately 25mA per relay.
A split level function allows the top and bottom halves of the sign to be illuminated independently via
separate inputs or by reversing the supply voltage allowing two stage messages to be displayed if
required.
The internal buzzer can be enabled or disabled via configuration switches and it can be silenced via a
two wire remote input.
The enclosure is slimline and attractively finished in a durable, neutral epoxy powder coat.
50
Elite Elite RS
SLC loop communications uses standard twisted pair cabling, shielded cable is not Available with one or two detection loops capable of hosting up to 600 devices.
necessary.
Elite RS uses leading edge microprocessor based electronics to provide a flexible
The panel may be configured with various communication cards; Communications control system with high reliability and integrity.
options support central station monitoring, Virtual Panel, and networking.
Suitable for all small to medium sized fire detection systems, Elite RS control panels
The Panel can be configured as a stand alone panel with just a few devices for a can be expanded and networked to become part of much larger systems if the need
small building, it can also operate as the building system and can be part of a network arises, therefore providing a future proof solution for any installation.
with a total of 64 nodes serving a multiple building campus or a very large facility.
With its large graphical display and ergonomic button and indicator layout, the
Auto Learn capability provides a convenient method to troubleshoot new Elite RS control panel is simple and straightforward to understand for installers,
installations before final programming is loaded. commissioning engineers and end users alike.
eMatrix eView
The eMatrix system uses flexible, optic light guides to illuminate areas on a floor plan, Designed and manufactured to the highest standards in a quality controlled
laid over a high resolution grid. This unique system dispenses completely with wiring environment the eView fire alarm annunciator provides a simple and convenient
and enables indicators to be moved, removed or added on site without the need for method of extending the controls and indications of the Elite fire alarm control panel
any wiring. to other locations.
All indicators can be configured to operate upon any event type and at point, zone The large, graphic liquid crystal display and high brightness LED indicators duplicate
or group level via the powerful and intuitive Loop Explorer configuration or ESP the indications on the Elite fire alarm control panel at up to 15 additional locations via a
Discovery. eMatrix can be supplied with or without LEDs and controls. Optional LEDs simple, two-wire serial data connection.
indicate Power on, Fire, Trouble and Disablement and optional controls are for Alarm
silence, Buzzer silence, Lamp test and Reset. The eView is powered by 24V DC (which can be via an additional 2 conductors from
the control panel or local 24V DC listed supply).
Housed in attractive, slimline enclosures to match Elite fire alarm panels and with high
quality, full colour or monochrome floor plans, eMatrix provides a clear, geographical eView is housed in a small enclosure which is styled similarly to the Elite control panel
indication of fire alarm activation enabling speedy identification of the source of an and is ideal for installations where a large control panel would be detrimental to décor
alarm. such as entrance halls.
51
Sigma A-CP Conventional Control Panel Sigma A-CP Features
UL Approved UL864 approved
Optional DACT
Compact enclosure
52
Sigma A-CP Overview Compatible Equipment & Extras
With 2, 4 or 8 initiating circuits all panels can be extensively configured via a simple front panel operated
programming method.
The low standby power requirements and cost effective small batteries allow the panel to be mounted in
a small discrete enclosure which is available in standard red or optionally in an attractive grey colour.
A simple programming method using just 3 front panel buttons allows an extensive list of configuration
options to be set and reviewed.
Single board construction which allows easy removal of all electronic parts by removing just 2 screws Sigma A-CP Ancillary Board See DS78
and ample provision of cable entry knockouts simplify installation.
4 Amp notification appliance power and built in selectable sync protocols provide ample power and
control for a wide range of standard notification appliances.
The built in RS485 communications bus provides the facility to connect 4 wire annunciators or ancillary
relay boards to provide further indication and control options throughout a premises.
The optional DACT allows dual line reporting to central stations and provides a 500 event history buffer.
53
Sigma A-XT Extinguishant Control Panel Sigma A-XT Features
UL/ FM Approved UL864 and FM listed
54
Sigma A-XT Overview Compatible Equipment & Extras
With three initiation circuits as standard, release can be configured to activate from any combination of
detection zone inputs to allow (among other combinations) any two from three type activations such as
would be required for detection in ceiling void, room and floor void applications.
The extensive configuration options of the Sigma A-XT allow the functionality of the system to be
extensively modified.
Sigma A-Si Status Units See DS73
The panel contains a large LED display to enable easy configuration and control which also displays the time
remaining until release for added user safety.
The countdown timer is duplicated on up to seven remote status units to provide local indication of the
system status.
With all of the electronics mounted on a single, easily removable, steel plate Sigma A-XT panels are both
robust and easy to install.
Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is
available in standard red or optional grey.
Sigma A-Si Hold Off Switch See DS73
55
Sigma A-Si Extinguishant Status & Ancillary Units
UL/ FM Approved
56
Sigma A-Si Features Sigma A-Si Overview Hold Off Overview
Easy access to terminals All units contain a large, LED display which shows The board provides volt free normally open contacts
a countdown of the time remaining until release in allowing control of sub-systems and plant remotely
Remote Auto/Manual door interlock input (supervised) seconds. from the main panel over a two wire data bus.
57
Syncro ASM Marine & Offshore Analogue Addressable Syncro ASM Features
1-2 Loop Control Panel 16 zonal LED indicators
5 programmable inputs
3 programmable relays
3A power supply
58
Syncro ASM Overview Compatible Equipment & Extras
Compatible with marine approved devices manufactured by Apollo Fire Detectors and Hochiki, Syncro
ASM provides a cost effective and scalable solution for all marine fire alarm systems.
Up to 64 Syncro ASM control panels may be networked to provide integrated control and indication of
over 16000 fire alarm points.
The optional Voyage Data Recorder interface outputs standard NMEA 0183 protocol and can be fitted
inside any control panel on the network.
Apollo Detectors & Devices See Kentec website
Suitable for all small to medium sized vessels, Syncro ASM control panels can be expanded and
networked to become part of much larger systems if the need arises, therefore providing a future proof
solution for any vessel.
With its large graphical display and ergonomic button and indicator layout, the Syncro ASM control panel is
simple and straightforward to understand for installers, commissioning engineers and end users alike.
59
Custom Custom Engineered Solutions Facilties
Expert design advice
Documentation
Electrical engineering
Electronic engineering
Metal finishing
Wire looming
Technical support
60
Custom Engineered Solutions
From the initial One of the key areas of our business is the design
design process and manufacture of bespoke equipment. Kentec
has considerable expertise in this field with over
25 years experience, so you can be certain that all
To sheet metal
fabrication custom engineered product will be designed and built
in accordance with your exact requirements and our
strict ISO 9001 approved quality procedures.
61
Custom Custom Engineered Solutions Applications
Smoke Damper Control Panels
62
Custom Engineered Solutions
Choose your
Finish
Choose your
Colour
Choose your
Specification
63
Kentec Electronics Ltd.