Environmental Inspection
Environmental Inspection
Compliance Inspections
Last Updated
Project
Package
Compliance 79%
Number ofNumber of Observations 47
20
15
Number of Observations
10
At Risk
5 Safe
PP
E ng SDS ons age nets ent pills aste ater ater ater
epi ti r i m S
ke Sta Sto ab tain W mw e W e W
e C r t l
ous
ash g &
ble on Sto as tab
n a C W Po
H ew dli m ary
Ey an
lam d
lH F on
eria Sec
at
M
COMPLIANCE INSPECTION SHEET - VEHICLE SAFETY
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Seat Belts worn by ALL occupants 0 0 -
Eye protection worn by occupants where windows
0 0 -
are down in travelling vehicles
Stop signs adhered to with vehicles coming to a
0 0 -
complete stop
Vehicles giving way where required 0 0 -
Appropriate speed being observed 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Traffic Control signage in place and followed 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Head Protection worn correctly and where
0 0 -
required
Correct form of eye protection worn for the area 0 0 -
Double Eye Protection worn where required 0 0 -
Hearing Protection worn in designated areas 0 0 -
Correct form of hand protection worn for manual
tasks 0 0 -
Respiratory protection worn where dust, mist or
fumes are present 0 0 -
Footwear in good condition/correct type 0 0 -
Hi-vis vest worn around mobile equipment and
0 0 -
escort duties
Safety Harness appropriately worn at height 0 0 -
Correct lanyard selected for application and
0 0 -
attached for 100% hook up
Additional Protective clothing used where required
0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Ladder positioned 1:4 and appropriately secured
0 0 -
top and bottom
Ladder positioned to facilitate ease of access /
egress without obstruction. 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are appropriate warning signs and barricading
displayed where hazards are evident 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is the work area clean & free of excess trash &
0 0 -
debris?
Construction materials laid out safely and
0 0 -
accessible
Material / equipment laid out on gluts / dunnage
for ease of access 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Has the plant log book been completed by the
0 0 -
operator as part of the pre-start check
Are guards in position and in good condition 0 0 -
Has a spotter been provided where required 0 0 -
Have adequate precautions such as flagging,
cones or warning signs been erected to warn of 0 0 -
hazards.
Are flashing lights or reverse warning alarms
operable where fitted 0 0 -
Other 0 0 -
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Hoisting and Lifting Equipment(Chain falls and Come-a-longs)
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is equipment properly inspected?
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - LIFTING / RIGGING
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are the cranes inspected on a daily basis or before use? 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET -STA
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Has a STA been developed for the task and
readily accessible at the workface
0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are cylinders secured in the upright position and
separation distances maintained for bulk fuels 0 0 -
Date:
Inspection Team:
Area:
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Has the plant log book been completed 0 0 -
Is a copy of the operator’s manual maintained with the machine
0 0 -
Is the EWP free from defect likely to affect the integrity of the
machines operation 0 0 -
Are operating controls legible and safety devices in an operable
condition 0 0 -
Is the self closing mechanism on the gate in a functional
condition 0 0 -
Is the EWP being operated in a safe manner i.e. proximity to
adjacent services, pipe racks, line of fire 0 0 -
Are harnesses worn and tied off inside of the platform?
0 0 -
Has a spotter / escort been provided and is within sight of the
operation of the machine 0 0 -
Is the spotter competent in the operation of the machine and
familiar with the emergency ground controls 0 0 -
Have adequate precautions such as flagging, cones or warning
signs been erected to warn of hazards 0 0 -
Is a Permit displayed on the machine for exiting the platform in
an elevated position 0 0 -
Is there a fire extinguisher in the platform and is it in working
order? 0 0 -
Is equipment staged in non-congested/obstructed fashion?
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - POWER TOOLS
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are the correct guards fitted to portable
0 0 -
power tools
Handles fitted where required 0 0 -
Leads free from defect indicating, employee
inspected prior to use 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is basket equipped with a guardrail system (top
and mid rail and toe board) and enclosed 0 0 -
construction between the toe board and the mid
rail (solid or expanded 1/2" metal)?
Is access gates provided with restraining device to
prevent accidental opening? 0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - SCAFFOLDING
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is the scaff-tag appropriately displayed at the entry point
to the scaffold indicating its status for use
0 0 -
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - CONFINED SPACE
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is the Permit currently valid for the Confined Space. 0 0 -
Permit requirements complied with - access, gas monitoring,
isolation, housekeeping, ventilation etc. 0 0 -
Confined space entry procedure is attached to permit with any
additional JSA's (STA). MSDS's attached to permit and 0 0 -
complied with.
Communications in place, suitable and understood by
employees. 0 0 -
JSA accounts for daily conditions and change management
processes 0 0 -
Access - internal & external conducive to safe entry. 0 0 -
Pre-entry briefing was conducted and sign off completed 0 0 -
Emergency evacuation plan in place and understood by
employees. 0 0 -
Stand-by person identified, in position, understands his
responsibilities. 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Contractors MSDS Register is maintained at an
accessible location known to employees.
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - ELECTRICAL 1
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are Ground Fault Circuit Interrupters (GFCI's)
utilized while operating power tools? 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - ELECTRICAL 2
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is equipment properly grounded? 0 0 -
Do GFCI's have proper color code? 0 0 -
Are GFCI's inspected and logged properly by
Competent Person? 0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Emergency Equipment/Emergency Preparedness
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Do employees know where assembly points are?*
0 0 -
Do employees know how to report an emergency?
0 0 -
*
Do employees know what to do if they hear
0 0 -
evacuation alarm?*
Is fire extinguishing equipment (hoses,
connections, nozzles) and the water truck readily 0 0 -
available if required on permit or STA?
Do employees know what to do in the event of
0 0 -
severe weather?*
Do employee(s) know the location of the nearest
0 0 -
eyewash station?*
Do employee(s) know the location of the nearest
0 0 -
fire extinguisher?*
Are emergency telephone numbers posted inside
0 0 -
all field offices?
Has the Emergency Response Team been
notified of existing hazardous tasks (confined
space entry, work at heights, unique tasks, etc.) 0 0 -
that may require a response in the event of an
incident? (see permit)
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - EXCAVATIONS
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are daily pre-entry excavation inspections
completed by an Excavation Competent Person
when excavations over 1 meter in depth? 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - PORTABLE EYEWASH STATIONS
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is this eye wash station designed to wash the
eyes with copious quantities of water for at least
15 minutes? 1 liter rinse bottles or similar 0 0 -
containers are not emergency eyewash stations.
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - FALL PREVENTION AND PROTECTION
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are guard rail systems in place where required to
0 0 -
prevent fall exposure?
Are Employees connecting to the required
anchorage points within the aerial lifting devices 0 0 -
(JLGs)?
Are employees working on scaffold where fall
protection is required using personal fall arrest 0 0 -
systems?
Are employees working above 1.8 meters using
personal fall arrest systems to achieve 100% fall 0 0 -
protection?
Are employees fall arrest lanyards connected
(above the harness D ring) to limit free fall 0 0 -
distance?
Are inspections of personal fall arrest system
components (harness, lanyards, rope grabs, etc.)
conducted as required and color coded for current 0 0 -
quarter?
Are employees aware of the proper anchorages?*
0 0 -
Are hole covers secure and properly labeled? 0 0 -
Where barricades are used to prevent access to
fall hazards, are they located at least 2 meters
away from the fall hazard? Are they visible during 0 0 -
darkness(if applicable)?
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - FALL PREVENTION - WORKING AT HEIGHTS
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Does STA address hazards and mitigation for
0 0 -
employees working at heights?
Is there appropriate signage on ladders and/or
platforms to indicate fall protection requirements? 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - FIRE PREVENTION/PROTECTION
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are applicable Work Permits completed and a
0 0 -
copy at the area/unit?
Is fire protection equipment outlined in the
permit/STA card at the work area (within 0 0 -
7meters)?
Is fire protection equipment inspection completed
before work begins and are inspection tags/color 0 0 -
code current? *
Is work area where welding, cutting or burning is
occurring free of flammable and combustible
materials within 10 meters or physically 0 0 -
protected?
Are appropriate personnel trained in fire watch
duties(designated fire watches or area fire 0 0 -
monitors)?
Are employees assigned to operate fire protection
equipment trained to use the applicable 0 0 -
equipment? *
Are oxygen/fuel gas systems equipped with
approved backflow prevention valves, flash 0 0 -
arresters, and pressure relief device(s)?
Are compressed gas cylinders stored upright and
0 0 -
secured?
Are compressed gas cylinders capped securely
0 0 -
when not in use?
Are the applicable flammable materials (greater
than 50 liters) stored in an approved and labeled 0 0 -
flammable liquid cabinet?
Are offices equipped with the proper number of
0 0 -
fire extinguishers?
Are the areas (with in1 meter) around mounted
0 0 -
fire extinguishers clear of obstructions?
Are smoking areas kept clean and are butt cans
0 0 -
available?
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Forklifts/Front End Loaders/Dirt & Equipment
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are daily inspections complete? 0 0 -
Are there NO signs of fluid leaks? 0 0 -
Are operators trained and authorized by their
0 0 -
supervisor to operate the equipment?
Are forks/buckets lowered as much as possible
0 0 -
(visibility) when traveling?
Are items being transported secured on pallets or
0 0 -
secured from falling/spilling?
Are spotters used when backing or operating in
0 0 -
congested areas?
Are operators obeying posted speed limits and
0 0 -
traveling in a safe manner?
Is equipment being operated only on stable
0 0 -
surfaces?
Are operators paying full attention to the task (For
0 0 -
example: not on cell phone)?
Are operators using seat belts? 0 0 -
Are lights operational on equipment used during
0 0 -
periods of low light?
Are back ups alarms, lights and horn operational?
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - General Safe Work Practices-I
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are employees following site smoking policies and
disposing of smoking materials in the proper 0 0 -
receptacles?
Are eye wash stations located in appropriate
0 0 -
areas and maintained?
Are employees wearing long sleeve shirts and
0 0 -
long pants? Or are FRC's required?
Are defective tools removed from the work area
0 0 -
and tagged?
Do tools have required guards in place? 0 0 -
Are GFCIs in use? 0 0 -
Are cords and hoses kept out of the walkway and
0 0 -
off of the working surface?
Are excess flow valves in use on air-supplying
0 0 -
hoses exceeding 1/2"?
Is the work area adequately illuminated? 0 0 -
Are all protruding reinforcement steel guarded to
0 0 -
eliminate the hazard of impalement?
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - General Safe Work Practices-II
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are employees aware of MSDS "book" location?
0 0 -
Are containers properly labeled? 0 0 -
Does the STA address chemical hazards? 0 0 -
Has the supervisor discussed the chemical
0 0 -
hazards with the employees?
Are employees aware of location of area Work
0 0 -
Permit?
Have the employees identified the nearest eye
0 0 -
wash and/or safety shower on the STA card?
Have the employees identified the proper
0 0 -
assembly point on the STA?
Have the employees identified the nearest fire
0 0 -
extinguisher on the STA?
Have employee identified the proper emergency
0 0 -
contact numbers on the STA?
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - HAND INJURY PREVENTION
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are employee keeping hands and arms away from
pinch points when performing their task(s)? 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are discussions concerning Heat Stress
Prevention performed in morning safety meetings 0 0 -
and documented on the STA?
Do employees know the signs of Heat Cramps?*
0 0 -
Do employees know the signs of Heat
0 0 -
Exhaustion?*
Do employees know the signs of Heat Stroke?*
0 0 -
Do Supervisors plan work if feasible to make use
0 0 -
of shaded areas?
Are fans, tarps, or cool down stations available?
0 0 -
If swamp coolers are in use, are they maintained
0 0 -
properly?
Do employees have unobstructed access to water
0 0 -
coolers?
Is cool / fresh water available throughout the work
0 0 -
day?
Are water coolers sealed and dated properly? 0 0 -
If work/rest periods are implemented, are they
being followed? 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - LOCK OUT/TAG OUT
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are all employees given Lock-out/Tag-out
0 0 -
Awareness training in New Hire Orientation?
Are all authorized employees and supervisor
0 0 -
trained in the Lock Out/Tag Out procedure?*
Is LOTO permit filled out correctly? 0 0 -
Is group lock out implemented correctly? 0 0 -
Are blinds properly tagged and identified? 0 0 -
Are locks identifiable as "lockout" locks and not
0 0 -
used for other purposes?
Was isolation verified --"test"? 0 0 -
Are vents or bleeds in the appropriate position?
0 0 -
0 0 -
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Material Handling & Storage
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are manual handling tasks discussed on the
0 0 -
STA?
Do project personnel participate in stretching? 0 0 -
Are mechanical methods used when needed? 0 0 -
Are employees wearing the appropriate gloves
0 0 -
when handling materials?
Are employees using proper lifting techniques? 0 0 -
Are incompatible materials segregated and stored
separately? (example: oxidizers and petroleum 0 0 -
based products)
Are hazardous materials stored separately and
0 0 -
protected from the elements?
Are storage areas orderly and is there an walkway
0 0 -
for access?
Are stored materials/pallets securely stacked at a
0 0 -
safe height?
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Pipe Stands 3 and 4 Legged
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is equipment properly inspected before
0 0 -
use(ask employee(s))?
Are manufacturer's labels/tags/ markings
0 0 -
legible?
Do employees understand various load
limitations based on 3 legged and 4 0 0 -
legged pipe stands?
Is pipe stand locking ring in place and
0 0 -
holding?
Is stand on firm, level surface? 0 0 -
Are supports or legs free from damage or
0 0 -
bent legs?
Is the yoke free from grease? 0 0 -
Are 3 legged stands being used to
0 0 -
support pipe 8 inches or smaller?
When using pipe stands on scaffolding
are scaffold(s) designed for the load(see 0 0 -
scaffold request)?
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - RESPIRATORS
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are respirators being used proper for the
0 0 -
hazard(see JSA or STA)?
Are respirators stored properly when not in use?
0 0 -
Are respirators being worn properly? 0 0 -
Is employee knowledgeable of field fit test?* 0 0 -
Does employee have proper medical clearance to
0 0 -
wear a respirator?*
Does employee have training on respiratory
0 0 -
hazards?*
Is respirator clean? 0 0 -
Does STA address respiratory hazards? 0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Steel Erection
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are employees 100% tied-off when elevated 1.8
meters off the ground and/or leading edge that 0 0 -
has a fall greater than 1.8 meters?
Is the area barricaded properly with the
0 0 -
appropriate barricade tape when making lift?
Has all rigging equipment/material properly
0 0 -
inspected?
Are employees watching pinch point hazards
0 0 -
when connecting/setting steel?
Is crane cab and rigger sounding horns and
0 0 -
whistles when a lift is being made?
Do nylon chokers have softeners in place to
0 0 -
prevent cuts and frays on rigging?
Is structural steel being hot bolted properly? 0 0 -
When exiting a manlift- has it been noted on STA
and signed by safety/site 0 0 -
superintendent/Construction Manager?
Do personnel have tool secured
0 0 -
properly(lanyards/bolt bag/tool pouch)?
Do personnel have bolts and nuts secured
0 0 -
properly(bolt bag)?
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - TOOLS & EQUIPMENT
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are hand tools in good condition? 0 0 -
Are power(electric, air, fuel) tools in good
0 0 -
condition?
Are electrical tools inspected per the Project
0 0 -
Procedures (color coding or GFCI inspection)?
Are employees carrying and hoisting tools
0 0 -
properly?
Are tools/equipment guards and handles in place?
0 0 -
Are hoses, cords, and leads in good condition:
0 0 -
free of cuts, melting or abrasion?
Are proper securing methods used on material to
be cut, drilled, welded, etc.? (For example: 0 0 -
sawhorses, clamps, jack stands)
Are the correct tools used for the job task(s)? 0 0 -
Are pneumatic tools properly connected and
sized: hoses, whip checks, locking pins, excess 0 0 -
flow valves?
Are persons NOT cleaning themselves with
0 0 -
pneumatic tools?
Are pneumatic cleaning devices proper- 30 psi
0 0 -
max (not homemade)?
Are damaged or worn tools and equipment tagged
and removed from service? 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - VEHICLES AND EQUIPMENT
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are daily inspections complete and does audit of
0 0 -
equipment match daily inspection?
If items are noted as non-functioning, has
0 0 -
supervisor been informed?
Are there NO signs of fluid leaks? 0 0 -
Are operators trained and authorized by their
supervisor(or third party) to operate the 0 0 -
equipment?
Is the driver obeying traffic signs? 0 0 -
Does the driver allow pedestrians to have the
0 0 -
right-of way?
Are forks/buckets lowered as much as possible
0 0 -
(visibility) when traveling?
Are items being transported secured on pallets or
0 0 -
secured from falling/spilling?
Are spotters/flaggers used when backing or
0 0 -
operating in congested areas?
If a manlift or crane, are areas properly
0 0 -
barricaded?
Is equipment being operated only on stable
0 0 -
surfaces?
Are operators paying full attention to the task (For
0 0 -
example: not on cell phone)?
Are operators using seat belts? 0 0 -
Are employees operating vehicles and equipment
0 0 -
NOT passing on roadways?
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - WORK ACCESS AND EGRESS
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is emergency equipment NOT blocked (Fire
Extinguishers, Eye Washes or Other 0 0 -
_____________________)?
Does walking or working path have minimal or
0 0 -
free of materials ?
Are ladders clear of obstructions at top and
0 0 -
bottom?
Are materials stacked/stored to prevent tipping?
0 0 -
Is there minimal excess materials in work area
0 0 -
(scrap or new materials)?
Are cords, hoses, leads arranged out of
0 0 -
walking/working path?
Are people standing on appropriate work surfaces
(for example, no buckets, no beams, scaffold rails, 0 0 -
etc.)?
Are Laminated Crane mats free of loops or
0 0 -
protected/secured?
Are Hard Wood Crane mats' lifting openings
0 0 -
covered or filled with rock/dirt?
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Flammable Cabinets (ENVIRO)
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are flammable cabinets free of trash and debris?
0 0 -
Is there any standing water/spills at the bottom of
0 0 -
the flammable cabinets?
Is the flammable cabinet properly ventilated? 0 0 -
Are there any containers in the flammable cabinet
that can be taken to disposal? (i.e. empty 0 0 -
containers, out-of-date chemicals)
Is there easy access to flammable cabinets? 0 0 -
Are all containers in the flammable cabinets
0 0 -
properly labeled?
Is excess liquid in containers less than 50 liters?
0 0 -
(excluding aerosol cans)
Are flammable cabinets grounded? 0 0 -
Is there a fire extinguisher within 10 meters of
0 0 -
flammable cabinet?
Is flammable cabinet secured? 0 0 -
Are proper fire symbols or signage on flammable
0 0 -
cabinet?
Are hazard materials stored away from other
0 0 -
incompatible hazardous materials?
0 0 -
0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Secondary Containments (ENVIRO)
Date:
Inspection Team:
Area:
Total 4 1 80%
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Environmental/Spill Prevention (ENVIRO)
Date:
Inspection Team:
Area:
Total 6 3 67%
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Environmental - Waste (ENVIRO)
Date:
Inspection Team:
Area:
-
-
Total 7 3 70%
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
The Column OBSERVATION refers to the number of situations observed with the same characteristic at the same work area.
The column NON COMPLIANT refers to the number of non compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Stormwater
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Does portable (compressors, generators, light
plants) equipment have adequate spill 1 0 100%
containment beneath (or internal to) it?
Does secondary containment contain all supports
and filling points and is containment properly 1 0 100%
erected?
Are any holes located inside the secondary
1 0 100%
containment? Is equipment running?
Are chemical mixing areas performed inside
0 0 -
containments?
Is equipment properly positioned in containment
and are containments able to hold 20% more than
the capacity of the tank/drums? 0 0 -
1
Date: Nov. 12, 2024
2
Inspection Team: 3 Company: ARCC
4
Area: TSF Sanitary Tanks Area
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Is sanitary wastewater collected on a regular
2 0 100% collected regularly
basis?
Is there any level indication for sanitary waste
2 0 100% installed level measurement equipment for 2 tanks
tanks?
Are sanitary waste tanks located in any secondary
0 2 0% no secondary containment or bundwall around the tanks
containment?
Are sanitary waste tanks easily accessible for
2 1 67% only 1 access door, need to provide a 2nd access/egress
emptying purposes?
Is sanitary waste infrastructure (pipes, tanks etc)
regularly inspected for condition and leaks? 2 0 100% checklist provided
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Are water storage tanks easily inspected 0 0 -
Are water storage tanks regularly cleaned 0 0 -
Are piping, valves and connections easily
0 0 -
accessible for cleaning
Are piping, valves and connections regularly
0 0 -
inspected and cleaned
Are all inlets and openings to tanks constructed so
that no foreign material may enter & contaminate 0 0 -
water?
Are transfer hoses constructed of safe & easily
0 0 -
cleaned materials
Are transfer hoses clearly identified as to their use
0 0 -
Are caps and keeper chains fitted to all water
0 0 -
inlet, water outlet and hoses?
Are all hoses stored off the ground so there is no
0 0 -
contamination?
Are all water delivery trucks solely used for the
0 0 -
delivery of potable water?
Are all water dispensers inspected & cleaned
0 0 -
regularly
Are all water storage igloos sealed, time & date
0 0 -
marked
Is all potable water checked for quality in
0 0 -
accordance with RCER
Are all water storage tank are clearly mark of what
0 0 -
type of water filled?
Are water filters been inspected and changed 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Camp - Kitchen & Mess hall
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Cleanliness and Hygiene of all areas shall be
adequately maintained. Checklist and system for
monitoring are developed and used. 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The column “Non Compliant” refers to the
number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Camp - Laundry
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant% Compliant Observation Comment
Cleanliness and Hygiene of the area shall be
adequately maintained. Checklist and system for
monitoring are developed and used. 0 0 -
1
Date:
2
Inspection Team: 3
4
Area:
5
Observation Criteria: Satisfactory Non Compliant % Compliant Observation Comment
Potable water testing and analysis records
available for review. Potable water tanks
and hoses protected from contamination. 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - Camp - Fire Prevention
Date:
Inspection Team:
Area:
Observation Criteria: SatisfactorNon Compli% Compli Observation Comment
Fire management plan in place and posted
-
Emergency evacuation routes & muster points easily identifiable
-
Means of Egress_ Are signs conspicuously posted and well lit. -
Are exit doors clear of combustible or other hazardous material. Corridors and exits
unobstructed (no storage of files, furniture, etc.). Adequate lighting in corridors, exits -
and stairwells.
Emergency Contact Numbers are conspicuously posted.
-
Regular and routine inspection and maintenance of fire extinguishers. Appropriate
inspection tagging system shall be visible. -
Adequate clearance (3 feet) for all fire extinguisher and hoses. Fire equipment in
proper locations and undamaged. -
Is the hose in cabinet properly racked and in good condition? Is the fire water storage
tank to proper level? -
Regular, routine inspection, maintenance and testing of smoke detection systems and
-
smoke alarms.
Fire detection and alarm systems tested regularly
-
Heat-producing appliances well ventilated. Electrical equipment turned off when not in
use. Malfunctioning electrical equipment immediately reported or taken out service. -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Project Requirements at the same work area. The column “Non Compliant” refers to the
number of non-compliances found with the same characteristic at the same work area.
COMPLIANCE INSPECTION SHEET - EXTENDED HOURS-NIGHT W
1
2
Inspection Team: 3
4
5
Observation Criteria: Satisfactory Non Compliant % Compliant Obse
Has Permit to Work been signed and readily
accessible at the workface 0 0 -
Total 0 0 -
INSTRUCTIONS: The Column “SATISFACTORY” refers to the number of observations where the activity or condition was deemed to be in compliance with Pro
column “Non Compliant” refers to the number of non-compliances found with the same characteristic at the same work
HOURS-NIGHT WORK
Date:
Area:
Observation Comment
med to be in compliance with Project Requirements at the same work area. The
characteristic at the same work area.