OUTPUT MODULE

ENGINEERED CATALOG
NUMBER
NOZZLES 1167

N80-053 THRU N80-066


Marine Suppression Systems LIQUID LEVEL
Architect and Engineer Specification FM - 3002238
INDICATOR
INDICAT
USCG - 162.161/2/0

DESCRIPTION

The function of the Fike Engineered Discharge Nozzle, in a Nozzle orifice drilling must be done at the Fike factory, or
fire extinguishing system, is to distribute the Clean Agent in other FM approved nozzle drill station, only after “As-Built”
a uniform, predetermined pattern and concentration. The calculations of the installed piping system(s) have been per-
nozzles are designed to complete the discharge of Clean formed, using the Fike Flow Calculation computer program.
Agent in 10 seconds, or less, when installed within the de-
sign limitations of the Fike Design, Installation & Mainte- The Fike Discharge Nozzle used shall be Factory Mutual
nance Manual, P/N 06-210 and the Fike Flow Calculation (FM) approved.
computer program.
ARCHITECTS SPECIFICATIONS
Fike Engineered Discharge Nozzles are available in sizes
of 3/8" (10mm) thru 2" (50mm). Each nozzle is available in The nozzle used to disperse Clean Agent shall be a Fike
180 and 360 degree discharge patterns. Series 80. The nozzle shall be available in 3/8" (10mm) thru
2" (50mm) sizes. Each size shall be available in both 180
The Discharge Nozzle size refers to the size of Schedule and 360 degree dispersion patterns. The nozzle used shall
40 or 80 steel pipe to which it can be connected. The nozzle have pipe threads that correspond to the nozzle size. All
discharge orifices are drilled perpendicular to the center line nozzles shall have an orifice size determined by an FM
of the threads and discharge on a horizontal axis. approved flow calculation program. All nozzle orifice drilling
shall be performed by the manufacturer or an FM approved
Nozzle orifices are available in a wide range of sizes to pro- nozzle drilling facility.
vide accurate Clean Agent flow results. All nozzles have
been tested for their ability to discharge the Clean Agent
under extreme conditions.

February, 2000
New Issue

704 S. 10th St. • P.O. Box 610 • Blue Springs, MO 64013-0610 U.S.A. • (816) 229-3405 • Fax (816) 229-4615 • E-mail fpssales@fike.com
Radius = 36' - 6" Radius = 23' - 1"
(11.1m) (7.04m)

Ceiling Ht. = 12" to 16-0' Ceiling Ht. = 12" to 16-0'


(30.5cm to 4.88m) (30.5cm to 4.88m)

NOZZLE SIZE 180O NOZZLE 360O NOZZLE


(NPT ) (mm) PART NUMBER PART NUMBER

3/8" (10) N80-060 N80-052

1/2" (15) N80-061 N80-053

3/4" (20) N80-062 N80-054

1" (25) N80-063 N80-055

1 1/4" (32) N80-064 N80-056

1 1/2" (40) N80-065 N80-057

2" (50) N80-066 N80-058

NOTES:

a. The maximum allowable area coverage includes any area within the radius distance from the nozzle ("R" dimension)
to the most extreme wall or corner.

b. Nozzles should be located on center line of hazard area.

c. When working with ceiling heights exceeding the values tabulated above, the hazard volume must be
broken down into vertically stacked hazard volumes, with heights less than the maximums shown in the
table.

It is imperative that unusual applications of this nature be handled by experienced design engineers
and, in most cases, operational tests should be performed before the system is put into service.

d. Dimensions and nozzle data shown are taken from the FM approved Design, Installation & Maintenance
Manual - P/N 06-210.

e. 180 and 360 degree nozzles may be placed a maximum of 1 foot (305mm) down from the ceiling, and 180 degree
nozzles may be placed a maximum of 1 foot (305mm) from the wall.

FORM NO. D1167 Copyright © 2000 by Fike Corporation All rights reserved PRINTED IN U.S.A.