NOTA

1 2 3 4 5 6 7

1a 2a 6a 6b 6c
LEGEND
CODE DESCRIPTION

1 TIGER

2 KIAP

3 FLAVOURS OF THE EAST


X Z
Ø200 Ø200 Ø200 Ø200 Ø200
4 FRATELLI'S (ARTISANAL FRESH PASTA)
rwdp rwdp rwdp rwdp rwdp

A Ø200
rwdp 5 HUNGRY BELLIES
Ø150
rwdp

6 THE BAO GUYS

7 LUSHBOWL
A1
8 R&D BURGER

A2 9 COOPER BY W1
SERVICE
LANE 10 44 & HETAM

11 LEEN'S (MIDDLE EAST KITCHEN)


FFL. +39.50
A3

made good to architect's instruction.


12 SOUTHERN ROCK SEAFOOD

Existing window to be maintained &


TAJUK PROJEK
A4 Ø150
13 HEJAU CADANGAN MENGUBAH SUAI JALAN
rwdp
STRACHAN, SENTUL WEST,
A5 14 TACO KING
51100 KUALA LUMPUR,
15 NOLABEL CUISINES WILAYAH PERSEKUTUAN KUALA LUMPUR
16 RED RED BOTAK HEAD
TANDATANGAN PEMILIK TANAH & BANGUNAN
B

w W
FFL. +39.65

Y FFL. +39.55 Y
B1
B2
EXISTING WAREHOUSE 1

EXISTING WAREHOUSE 3

TAJUK LUKISAN
LAYOUT PLAN
SERVICE LANE

B3
B4 GROUND FLOOR PLAN

Ø150
rwdp
B5
TANDATANGAN ARKITEK

B7

Ø150
rwdp
Ø200
C 500 rwdp

Ø200 Ø200 Ø200 Ø200


rwdp rwdp rwdp rwdp

X Z MAIN ENTRANCE

FF 01
GENERAL NOTE FOR CONSTRUCTION
UiTM Cawangan Selangor
1. ALL WORKS TO BE CARRIED OUT MUST BE INACCORDANCE TO B.B REQUIREMENTS Kampus Puncak Alam
2. ANY DISCREPANCY BETWEEN ARCHITECTURAL AND ENGINEERING Bandar Puncak Alam,
DRAWING MUST BE BROUGHT TO THE ATTENTION OF THE RBD IMMEDIATELY
42300 Puncak Alam,
AND INSTRUCTION MUST BE OBTAINED FROM THE RBD BEFORE PROCEEDING FURTHER
3. NO DIMENSION ARE TO BE SCALED FROM THE DRAWING. ANY MISSING DIMENSION Selangor
MUST BE OBTAINED FROM THE RBD CONCERNED
4. ALL STEEL AND R.C STRUCTURAL WORK TO BE CONSTRUCTED TO ENGINEER'S DETAIL
AND SPECIFICATION UNLESS STATED OTHERWISE FAKULTI
LOADING

5. NO VARIATION OF COSTS WILL BE ALLOWED DUE TO WORKS COMPLETED AND


BAY

KOLEJ PENGAJIAN ALAM BINA


SUBSEQUENTLY ASKED TO BE DEMOLISHED AS A RESULT OF THE DISCEPANCY BETWEEN
ARCHITECTURAL AND ENGINEERING DRAWING
6. SITE TO BE DEMARCATED AND CHECKED BEFORE ANY WORKS COMMENCES
7. ALL SANITARY LAYOUT PLAN SHALL BE SUBMITTED TO LOCAL AUTORITIES BEFORE WORKS
JABATAN
COMMENCES
8. ALL CULVERTS SHALL BE CONSTRUCTED TO THE APPROVAL OF THE LOCAL AUTHORITIES JABATAN SENI BINA DALAMAN
9. ALL BRICKWALL TO BE REINFORCED WITH 'EXMET' OR EQUIVELENT AT EVERY 4TH COURSES
10. ALL DIMENSIONS ARE TO BE CHACKED AND VARIFIED ON THE SITE BEFORE
COMMENCEMENT OF ANY WORKS AUTHORITIES BEFORE CARRYING OUT ANY PLUMBING WORKS
11. ALL APPROVED J.B.A PLUMBERS MUST THEIR NAMES AND APPLICATION FROM TO LOCAL KURSUS
12. REINFORCED CONCRETE LINTOL SHALL BE PROVIDED OVER ALL DOOR. WINDOWS AND
OPENING WHERE NECESSARY INA 521 - REKA BENTUK DALAMAN
13. ANTI CORROSIVE PAINT TO ALL IRONWORKS UNLESS OTHER WISE STATED SPECIFICALLY.

Studio Part 4,
CALCULATION OF PARKING SPACE : 46.4 sq.m. (500 SQ) = 1 LOT
Bangunan Alam Bina,
UiTM Cawangan Selangor,
TOTAL NET FLOOR AREA OF ONE BUILDING FLOOR (26' X 65') : 934.81 sq.m. - 10% SERVICE AREA = 841 sq.m. Kampus Puncak Alam,
TOTAL NET FLOOR AREA OF ONE BUILDING FLOOR (26' X 75') : 1038.90 sq.m. - 10% SERVICE AREA = 934 sq.m. 42300 Puncak Alam,
TOTAL NET FLOOR AREA OF ONE BUILDING FLOOR (22' X 75') : 2028.06 sq.m. - 10% SERVICE AREA = 1826 sq.m. Selangor
TOTAL NET FLOOR AREA OF ONE BUILDING FLOOR (22' X 65') : 2018.74 sq.m. - 10% SERVICE AREA = 1817 sq.m
TOTAL NET FLOOR AREA OF ONE BUILDING FLOOR (22' X 80') : 1964.08 sq.m. - 10% SERVICE AREA = 1768 sq.m.
TOTAL NET FLOOR AREA OF ONE BUILDING FLOOR (22' X 88' MIN) : 1964.08 sq.m. - 10% SERVICE AREA = 1768 sq.m.
DILUKIS OLEH : IRFAN & HAFIZ
TOTAL NET FLOOR AREA OF THE ENTIRE FLOOR OF A BUILDING : 9948.67 sq.m.
MENTIONED ABOVE (NOT INCLUDING 10% OF SERVICE SPACE SUCH AS STAIRS,
DISEMAK OLEH :
N TOILET, A/C LEDGE, REFUSE COMPARTMENT)

GROUND FLOOR PLAN CALCULATION OF PARKING SPACE


NECESSARY PARKING SPACE
:
:
46.64 sq.m. (500KP) = 1 LOT
89.54 sq.m. (NET AREA NOT
INCLUDING SERVICE AREA) / 46.4 sq.m.
TARIKH : 3 NOVEMBER 2022

SCALE 1:200 SCALE : 1 : 200


TOTAL PARKING SLOTS REQUIRED = 193 LOT
TOTAL PARKING SLOTS PROVIDED = 169 LOT
NO LUKISAN :
AP247/4A/INA521/2022/LP01