0% found this document useful (0 votes)
35 views3 pages

Combined File

Uploaded by

Rohit Singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views3 pages

Combined File

Uploaded by

Rohit Singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Legend

Total Builtup Area in Total Net FSI Area in


Block Name Floor Name Sq.m. Sq.m.

PROPOSED PLAN FOR THE HOUSE OF SH. Others


FLOOR-GROUND 244.4192 244.0476

NORTH SIDE - PROPERTY OF MELA RAM LINCON GOYAL S/O SH. KAUSHAL KUMAR AT FLOOR01 134.0359 134.0359

78'-0"
WARD NO. 6, GALI NO. 3, MODEL TOWN KURALI, Grand Total 378.4551 378.0835

TO ROPAR
TEHSIL KHARAR, DISTT. S.A.S. NAGAR (PB.) Floor Space Index 0.72

REAR OPEN BELOW TO M.C. Plot Coverage 47%


10'-0"

10'-0"
3.0480

OFFICE
KHASRA NO. 58//19/3/1(1-12), 4/2(1-6) Applicant Name LINCON GOYAL

C.CONC. STREET
C.CONC. STREET
Gali no. 3, Ward no. 6, Model Town, Kurali, Tehsil Kharar, Distt.
Proposed Address
S.A.S. Nagar

AMRIK
SINGH
H/O
BANSAL
DETAIL OF AREA

C.CONC. STREET
HOSPITAL
TERRACE MEDICAL
C.CONC. STREET

18'-0" WIDE
CIVIL
STORE

C.C.
18'-0" WIDE
13'-6"

13'-6"
TOTAL PLOT AREA = 5616 SQ.FT. OR 624.00 SQ.YDS. OR 521.93 SQ. MTR.

H/O KRISHAN
N.H.--21

LAL PANDIT
C.CONC. STREET
C.CONC. STREET C.CONC. STREET PROP. COVD. AREA ON G.F. = 2800.60 SQ. FT. OR 260.22 SQ. MTR.

18'-0" WIDE
18'-0" WIDE 18'-0" WIDE
PROP. COVD. AREA ON F.F. = 1442.66 SQ. FT. OR 134.07 SQ. MTR.

EAST SIDE - HOUSE OF SUSHIL KUMAR


TOTAL COVD. AREA = 4242.66 SQ. FT. OR 294.29 SQ. MTR.
WEST SIDE - 16'-6" WIDE STREET

0.0000 0.0000

BOUNDARY WALL = 262.25 RFT. OR 79.95 MTR

ROAD
10'-9"

ED
15'-5"

C.CONC. STREET
COVERED

MATTEL
18'-0" WIDE ALLOWED COVERAGE 50% 49.86%
FRONT SETBACK

OF RAJ
KUMAR
HOUSE
6.17M 6.17M

HOUSE HOUSE
EXIST. EXIST.
EXIST. HOUSES REAR/SIDE SETBACK 3M (CLAUSE 4.13)
72'-0"

3.05M

MATTELED ROAD
OPEN SPACE 50% 50.14%

30'-0' WIDE

MATTELED ROAD
PLOT
TERRACE HEIGHT 15M 7.695 M OR 25'-2"

30'-0' WIDE
PUCCA ROAD
11'-6"

40'-0' WIDE
F.A.R. 1:2.00 1: 0.755

PLOT

HOUSE
EXIST.

EXIST. HOUSE
EXIST. HOUSES
DETAIL OF JOINERY

TO US STAND
12'-10"

EXIST. HOUSES
EXIST. H/O EXIST. H/O

KURALI
EXIST. H/O
TERRACE LOVELY AGG. DR.RAJIV AMANDEEP EXIST. HOUSES
D = 4'-0" x 10'-0" W2 = 6'-0" x 6'-0"
C.PAWER STREET 30'-0' WIDE C.PAWER STREET 30'-0' WIDE C.PAWER STREET 20'-0' WIDE
D1 = 4'-0" x 7'-6" W3 = 10'-0" x 8'-0"
.
.
D2 = 3'-6" x 7'-6" W4 = 2'-6" x 4'-9"

EXIST. H/O
HOUSE
D3 = 3'-4" x 7'-6" W5 = 12'-0" x 10'-0"

HOUSES
EXIST.

JARNAIL

EXIST.
SINGH
OF HARISH KUMAR
HOUSE
WCN = 6'-1021" x 4'-9"

HOUSE
D4 = 2'-6" x 7'-6"

20'-0" W. KATCHA RASTA


EXIST.
V = 6'-0" x 3'-6"

K UNION

C.CONC STREET 18'-0"WIDE

C.CONC. ST.
PLOTS
0 5' 10' 20'
V1 = 3'-0" x 3'-6" MAIN GATE = 10'-0" WIDE

11'-0' WIDE
HOUSE
EXIST.
26'-3"

.
. W = 9'-621" x 6'-0"

TO TRUC
LOCATION PLAN : NTS
HOUSE

SITE
20'-3"

FRONT OPEN BELOW OF SUSHIL


20'-0" W. KAT. RASTA
11' W1 = 9'-0" x 6'-0"
EXIST. HOUSES
6.1722

KUMAR

HOUSE
EXIST.
.
1 PLINTH LEVEL 0.45M ABOVE N.G. LVL. 0.6M ABOVE N.G. LVL.
C.CONC STREET 18'-0"WIDE 2 MIN. VENTILATION (% OF FLOOR AREA) 20% 36.81%
3 MIN. AREA OF 1 HABITABLE ROOM 9.5 SQ. M 12.85 SQ. M
MAIN GATE
EXIST. HOUSES 4 BATHING MIN. AREA 1.8 SQ. M -NA-
EXIST. HOUSES
5 BATHING MIN. WIDTH 1.2 M -NA-
SOUTH SIDE - 18'-0" WIDE STREET 6 W.C. MIN. AREA 1.1 SQ. M 2.23 SQ. M
7 W.C. MIN. WIDTH 1.2 M 1.21 M

SITE PLAN LOCATION PLAN 8 KITCHEN MIN. AREA 5 SQ. M 15.61 SQ. M
9 KITCHEN MIN. WIDTH 1.8 M 3.66 M
10 MM PLASTER
INSIDE-OUT
10 TOILET MIN. AREA 2.8 SQ. M 3.90 SQ. M

9" BRICK WALL


11 TOILET MIN. WIDTH 1.2 M 1.83 M
10"2'-6"

10"2'-6"
12 STAIRCASE MIN. WIDTH 0.9 M 1.07 M
P. LVL. 13 STAIRCASE MIN. TREAD 0.25 M 0.254 M
WATER PROOFING 14 STAIRCASE MAX. RISER 0.175M 0.175M

2'
1-12" TH. TILE TARRACING N.G. LVL. 15 MIN. HEADROOM BELOW LANDING 2.20 M -NA-
10'-6"

10'-6"

3" TH. MUD PLASTER

6" 6" 6" 6" 6" 6"


9"
2 COATS OF HOT BITU.
4-12"TH. R.C.C. SLAB
1"
1'-12 12MM PLASTERING 16 MIN. COURTYARD LEVEL 150 MM ABOVE N.G. LVL. -NA-
1'-6"
(1:5)
HEIGHT OF PARAPET WALL 1.0 M 1.0 M

3'
1'-1021"
6" P.C.C BEDDING 17
2'-3"

18 RAIN WATER HARVESTING APPLICABLE PROVIDED


10"

10"

3'
25'-2"

25'-2"

19 FIRE N.O.C. -NA- -NA-


20 AREA OF PARKING 1 ECS/100 SQ.M. 9.24 ECS PROVIDED
11'-0"

11'-0"

21 MIN. WIDTH OF CAR PARKING 2.5 M 2.5 M


10MM PLASTERING
(1:6)

P.LVL. +2'-0" P.LVL. +2'-0"


2'-0"

2'-0"

N.G.LVL. 00 N.G.LVL. 00

1-12" TH. FLOOR FINISHING


FOUNDATION DETAIL
3" TH. C. CONC.
9" BRICK WALL
FRONT ELEVATION SECTION - XX' 3" TH. BRICK BALLASET
2'-7-12"TH. EARTH FILLING

9" 17'-0" 9" 13'-0" 9" 11'-121" 421" 4'-0" 9" 17'-0" 9" 11'-0" 9"
78'-0" MODERN BUILDING DESIGNERS
OFF. OPP. M.C. OFFICE KURALI.
4 X Ø16MM
REAR YARD REAR YARD 9" ISI REBARS
10'-0"

10'-0"

10'-0" WIDE BELOW


N.G. LVL. +2'-0" 9" 17'-421" 9" 7'-0" 9"
PROJECTION 3'-0" WIDE 6" DISTANT
BINDING REBAR

G.T. C W C V C W3 C V G.T. P. LVL.


C W3 W3
KHURRA
C V
KHURRA

C
9"
9"

9"

D1 C

2'
TOILET' TOILET N.G. LVL.
PASSAGE 4' W.

TOILET TERRACE
11'-1-12" X 6'-3" 11' X 6' BED ROOM 7' X 6'-7-12"
N.G. LVL. +13'-10"
BED ROOM D4 BED ROOM 17'-4-12" X12'
12'-0"

12'-0"
12'-0"

M20 CONCRETE
17'-0" X 12'-0" STORE/DRESSER 17'-0" X 12'-0"

3'-6"
D4

4'
13' X12' PROJECTION 3'-0" WIDE
DRESSER 6" DOUBLE NET
POOJA
11' X5'-7-12" DRESSER P.C.C BEDDING
8' X 5'
D2

6"
7' X5'-0"
C C C
D2
9"
9"

9"

C D3 D2 C C C D2
W2 W2 C
8'-121"
UP
TERRACE

3'
PROJECTION 3'-0" WIDE DRAWING ROOM OPEN YARD
10'-9"

W2 OPEN YARD BELOW


LIVING ROOM 16' X 8'-1-12" LIVING ROOM 3" 9" 3"

3"
W5
41'-9"
14'-9"

14'-9"

GREEN LAWN/OPEN YARD 38'-1-1/2" X14'-9" 38'-1-1/2" X14'-9" 6" DOUBLE NET

3" 9"
3'
13'-6" X14'-9" W5 N.G. LVL. +2'-0" P.C.C BEDDING
N.G. LVL. +13'-10"
DN UP
72'-0"

72'-0"

A D ENTRY STEPS
N.G. LVL. +2'-0"
C C C C FOUNDATION DETAIL
X D2 C
X'
9"

D2
9"

C D4 C C D2 D2
C C
W3
9" X 9" RC.C. COLUMN

Varinder
PORCH
W4 14' X11'-6" TERRACE
V1 TOILET
PD. ROOM
4'X6' V1 TOILET N.G. LVL. +13'-10" Digitally signed by Varinder Jain
17'-6"

7'X6' KIT.ST. N.G. LVL. +1'-0" 7'X6'


OPEN
4'-6"X 7'-6" D4 BED ROOM OPEN STORE OOM DN: c=IN, o=Personal,
12'-0"

12'-0"

BED ROOM DUCT


DINNING 18'-9" X12'
DUCT
14'-0" X 9'-0"
D4
16'-2.5" X12' 12'-8-1/2" X 12'
KITCHEN
14'-6" X 12'-0"
C D4
TERRACE 2.5.4.20=5abab144953b5935bea8b7cec0b
DRESSER
G.T.
DRESSER
N.G. LVL. +13'-10" KHURRA
fdf5e33415c8b669ca9bbd206f6ea15c5edd
7' X5'-7-12" 7' X5'-7-12"
b, postalCode=160020, st=CHANDIGARH,

Jain
W2
C
D3 serialNumber=0ed11a9af332408146b2f22
9"

9"

D3 I.C.

9ec472326ccdc3d67e4c97a49de07c5ca80f
C C C C W C KHURRA
W W1 WCN CAST R.C.C SLABS
G.T.
PROJECTION 3'-0" WIDE RECHARGE BORE HOLE PIT
OPEN PARKING
RAIN R.C.C PRECAST SAND 52960, cn=Varinder Jain
WATER COLLECTION TANK
PROJECTION 3'-0" WIDE
PIT
OPEN TO SKY Date: 2021.07.09 09:41:16 +05'30'
9" 7'-0" 9" 18'-9" 9" 10'-3" 9" 14'-0" 9"
SOHEEN SURFACE OF ONOLID
4'-3" 9" 7'-0" 9" 16'-221" 421" 12'-821" 9" 14'-6" 9" 4'-6" 9" 14'-9"
UPPER FOR NON OF
20'-3"

20'-3"

CAST IRON PIPE


FRONT GREEN G.I. & PVC PIPES
FRONT GREEN LAWN/OPEN YARD
LAWN/OPEN YARD BELOW UNDER GROUND BORE5'-6'
N.G. LVL. +1'-0"
BELOW THE SAND SHLATA
GROUND SAND SHLATA
SOILING WATER
MAIN GATE
RECHARGE BORE HOLE PIT

78'-0"

GROUND FLOOR PLAN FIRST FLOOR PLAN RAIN WATER RECHARGE PIT
Building Permit/Sanction

File/B.A. No. PB/SAS/KURAL/87586 Dated 08-07-2021

To: LINCON GOYAL, Kurali

Subject: Sanction u/s 262(1) of PMC Act,1976/PM Act,1911.

Dear Sir or Madam,

With reference to your application dated 08-06-2021. for the grant of sanction to erect/re-erect/add
to/alteration in the building to carry out the development specified in the said application relating to Plot/Site
No. 00 Ward no. 06 situated in/at Gali no. 3, Ward no. 6, Model Town, Kurali, Tehsil Kharar, Distt. S.A.S.
Nagar. I have to state that the Authority subject to the following conditions and corrections done in the plans
has sanctioned the same on 08-07-2021.

The plans are valid up to three year

1. The construction will be undertaken as per sanctioned plan only and no deviation from the bye-laws will be
permitted without prior sanction. Any deviation done against the bye-laws is liable to be demolished and the
supervising Architect/Professional engaged on the job will run the risk of being black listed.

2. Violation of building bye-laws will not be compounded.

3. It will be the duty of the owner of the plot and the Architect/Professional preparing the plans to ensure that
the sanctioned plans are as per prevalent Master Plan/Zonal Plan/Building Bye-laws. If any infringement of
bye-laws remain unnoticed, the concerned Authority reserves the right to amend the plans as and when
infringement come to the notice and concerned Authority will stand indemnified against any claim on this
account.

4. A notice in writing shall be sent to Authority before commencement of the construction of the building as
per bye-laws. Similar notice will be sent to Authority when the building has reached up to plinth level.

5. The owner shall not occupy or permit to occupy the building or use or permit to use the building or any part
thereof affected by any such work until occupancy certificate is issued by the concerned Authority.

6. Concerned Authority will stand indemnified and kept harmless from all proceedings in court and before
other authorities of all expenses /claims which the concerned Authority may incur or become liable to pay as
a result or in consequences of the sanction accorded by it to these building plans.

8. The doors and window leaves shall be fixed in such a way that they shall not, when open project on any
street.

9. The owner will not convert the house into more dwelling units on each floor then the sanctioned.

10. The building shall not be constructed within minimum distance as specified in Indian Electricity Rules
from voltage lines running on side of the site.

11. The land left open as a consequence of the enforcement of the setback rule shall form part of the public
street.

12. The owner shall ensure that the public areas like road, parks and other public opens spaces are not used
for stacking the building materials or machineries to avoid public inconvenience and nuisance.

13. The sanction will be void if auxiliary conditions mentioned above and other conditions whatsoever
imposed are not complied. 14. The owner will use the premises for the use, which has been sanctioned.

15. The owner will not proceed with the construction without having the supervision of an
Architect/Professional as the case may be. If he\she changes his Architect/Professional, he\she shall inform
the Authority about the appointment of new Architect/Professional within 48 hours, with a proper certificate
from him.

Yours Faithfully.

Varinder Digitally signed by Varinder Jain


DN: c=IN, o=Personal,
2.5.4.20=5abab144953b5935bea8b7cec0bfdf5e33415c8b66
9ca9bbd206f6ea15c5eddb, postalCode=160020,

Jain
st=CHANDIGARH,
serialNumber=0ed11a9af332408146b2f229ec472326ccdc3d
67e4c97a49de07c5ca80f52960, cn=Varinder Jain
Date: 2021.07.09 09:43:22 +05'30'

Encl: A set of sanctioned plan.

You might also like