Data sheet 6AV7260-.....-....

SIMATIC IPC677D (Panel PC), 2x10/100/1000 Mbit/s Ethernet; 4x USB V3.0, 1x


serial (COM1); Watchdog, temperature and Fan monitoring; RAID controller
onboard

Installation type/mounting
Mounting For horizontal and vertical mounting
Design Panel PC, built-in unit
maximum permissible installation angle +/- 20°
Supply voltage
Type of supply voltage 100/240 V AC (autorange); 24 V DC
Line frequency
● Rated value 50 Hz Yes
● Rated value 60 Hz Yes
Mains buffering
● Mains/voltage failure stored energy time 10 ms
Processor
Processor type Celeron G1820TE (2C/2T, 2.2 GHz, 2 MB Cache); Core i3-4330TE (2C/4T, 2.4
GHz, 4 MB Cache); Xeon E3-1268L v3 (4C/8T, 2.3 (3.3) GHz, 8 MB Cache,
AMT)
Chipset Intel DH82C226 PCH
Graphic
Graphics controller Intel HD graphics controller P4600 GT2 (Xeon, Core i3); Intel HD graphics
controller (Celeron)
Drives
Optical drives DVD±R±RW combi-drive, optional
Hard disk 3.5" SATA ≥ 500 GB, optional: 3.5" SATA ≥ 1 TB; RAID1 2x 2.5" SATA ≥ 320
GB; solid-state drive (SSD) ≥ 240 GB; all hard disk drives within the enclosure
are vibration-damped; RAID1 2x 2.5" SATA ≥ 320 GB byte in removable drive
bay
SSD Yes; ≥ 240 GB optional
Memory
Type of memory DDR3-1600 DIMM
Main memory 2 / 4 / 8 / 16 GB; ECC optional
Capacity of main memory, max. 16 Gbyte
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 2 Mbyte; 128 KB can be stored in the buffer time; optional
Hardware configuration
Slots
● free slots 2x PCI; optional: 1x PCI & 1x PCIe (x16); 2x PCIe (x4, x16); with card retainer
● Number of PCI slots 2
● Number of PCI slots 2
Interfaces
PROFIBUS/MPI Optionally onboard, isolated, max. 12 Mbit/s, compatible with CP 5622
Number of industrial Ethernet interfaces 2; 2x RJ45 (independent)
Number of PROFINET interfaces 3; Optional

6AV7260......... Subject to change without notice


9/11/2023
Page 1/3 © Copyright Siemens
USB port 4x USB 3.0
Connection for keyboard/mouse USB / USB
serial interface 1x COM1 (RS 232), optional: 1x COM2 (RS 232)
parallel interface optional LPT1
Video interfaces
● Graphics interface 1x DisplayPort and 1x DVI-I; 1x VGA via adapter cable (optional)
Industrial Ethernet
● Industrial Ethernet interface onboard, 2x 10 / 100 / 1 000 Mbit, RJ45
— 100 Mbps Yes
— 1000 Mbps Yes
Interrupts/diagnostics/status information
Bus diagnostics Yes
Integrated Functions
Monitoring functions
● Temperature monitoring Yes
● Watchdog Yes
● Status LEDs Yes
● Fan Yes
● Monitoring function via network Optional
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of static ±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC
electricity 61000-4-2
Interference immunity against high-frequency electromagnetic fields
● Interference immunity against high frequency radiation 10 V/m for 80 - 1 000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3
V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz,
80% AM acc. to IEC 61000-4-6
Interference immunity to cable-borne interference
● Interference immunity on supply cables ±2 kV acc. to IEC 61000-4-4, burst; ±1 kV acc. to IEC 61000-4-5, surge
symmetric; ±2 kV acc. to IEC 61000-4-5, surge asymmetric
● Interference immunity on signal cables >30m ±2 kV acc. to IEC 61000-4-5, surge, length > 30 m
● Interference immunity on signal cables < 30m ±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4;
burst; length > 3 m
Interference immunity against voltage surge
● asymmetric interference ±2 kV acc. to IEC 61000-4-5, surge asymmetric
● symmetric interference ±1 kV acc. to IEC 61000-4-5, surge symmetric
Interference immunity to magnetic fields
● Interference immunity to magnetic fields at 50 Hz 100 A/m; to IEC 61000-4-8
Emission of conducted and non-conducted interference
● Interference emission via line/AC current cables EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A
Degree and class of protection
IP degree of protection IP20
IP (at the front) IP65
IP (rear) IP20
Standards, approvals, certificates
CE mark Yes
UL approval Yes
● UL 508 Yes
cULus Yes
RCM (formerly C-TICK) Yes
KC approval Yes
FCC Yes
EMC CE, EN 61000-6-4:2007, EN 61000-6-2:2005
Ambient conditions
Ambient temperature during operation
● min. 5 °C
● max. 45 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Relative humidity Tested according to IEC 60068-2-78, IEC 60068-2-30: 5% to 80% at 25 °C (no

6AV7260......... Subject to change without notice


9/11/2023
Page 2/3 © Copyright Siemens
condensation)
Vibrations
● Vibration resistance during operation acc. to IEC 60068- tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to
2-6 500 Hz 9.8 m/s² (1 g)
Shock testing
● Shock load during operation Tested to DIN IEC 60068-2-29: 50 m/s² (5 g), 30 ms, 100 shocks
Operating systems
pre-installed operating system Windows 7 Ultimate, 32-bit/64-bit, MUI; Windows Embedded Standard 7 P, 32-
bit, MUI; Windows 10 Enterprise 2015 or 2016 LTSB, 64-bit, MUI
without operating system Yes
pre-installed operating system
● Windows 7 Yes; Ultimate 32 bit or 64 bit
● Windows 10 Enterprise Yes; Windows 10 Enterprise 2015 or 2016 LTSB, 64-bit, MUI
Software
SIMATIC Software Optional package with SIMATIC WinCC or WinAC RTX