DATA SHEET
3 Phase Squirrel Cage Induction Motor
Customer : AMAN INTERNATIONAL BBL Ref No : 10168206/10 Quantity : 1 Nos
Consultant : -- Tag Nos :
--
Project : --
Product Type : Inverter Operated IE3 Efficiency Flameproof Motor
Output (kW)/Poles : 15 / 2P Frame Size : 160M
Voltage (V) : 415 +/- 10% Area Classification : Hazardous Area
Frequency (Hz) : 50 +/- 5% Type of Ex Protection : Ex db
Duty : S1 (Continuous) Gas group / Temp. Class : IIA,IIB / T3
Altitude (m) : < 1000 Approving Authority : PESO
Amb Temp/ Temp Rise : 50°C / 75K Enclosure / Cooling Type : TEFC / IC411
Insulation Class : F Location-Indoor/Outdoor : Outdoor
Temp. Rise Class on DOL : B Mounting : B5
Rated Current (Amps) : 26.1 Degree of protection : IP55
Rated Speed (RPM) : 2945 T Box Position from DE : TOP
Rated Torque (kgm) : 4.96 Type of coupling : Direct
Service Factor (SF) : 1.00 Type of Bearing (DE/NDE) : Ball / Ball
SF Current (Amps) : -- DE / NDE Bearing : 6209 2Z C3 / 6209 2Z C3
Efficiency & Power factor : Lubrication : Lithium soap base grease
% Full Load % Efficiency Power Factor Connection / No. of terminals : Delta / 6
100% 91.9 IE3 0.87 Cable Size : 3.5C x 25 SQMM
75% 91.9 0.84 Main T.Box ET Size : 2XM25X1.5P
50% 90.0 0.77 Weight in kg (Approx) : 164
Locked Rotor Current (% Full Load) : 650% Direction of rotation : Bidirectional
Locked Rotor Torque (% Full Load) : 230% Paint Type : Acid Alkali Proof(Epoxy)
Breakdown Torque (% Full Load) : 280% Paint Shade : 632
L.R. Withstand Time Hot/Cold (sec) : 8 / 16 Noise level (dBA) : As per IS12065
Application : Other - Variable Torque Vibration level (mm/sec) : As per IS12075
Type of Load Torque : Variable Torque Brake Type : N.A.
Method of starting : VFD Braking Torque : N.A.
Speed Variation on VFD : 50-100% Brake release time (ms) : N.A.
Rotor GD2 (kgm2) : 0.217 Brake application time (ms) : N.A. (AC Side interruption)
Load RPM : Customer to Furnish Accessories :
Load GD2 (kgm2) : Customer to Furnish , , , PTC 3Nos. (1/phase), ,
Starting time (sec) : 0.5 Load GD2=Motor GD2 0.8 0.4
No. of consecutive starts : 2 Hot / 3 Cold
Additional data 1 :
Additional data 2 :
Applicable Standards : IS/IEC60079-1,IS12615, IS1231, IS2223, IS12065, IS12075
Remarks : Sealing box
18.11.2023
Notes
1) All performance values are subject to IS15999-1 tolerances, unless otherwise specified. 18.11.2023
2) Performance values are at rated voltage and rated frequency condition and for DOL starting condition.
3) Motor GD2 = Load GD2 assumed wherever not mentioned.
4) Where starting time is more than 10 seconds, provision of heavy duty relays is mandatory.
5) Application check not made in absence of load details, customer has to ensure motor suitability at his end
6)Unused cable entry must be filled with suitably certified stopping plugs.
Notes for VFD Motors
1) Motors suitable to run on VFD supply are designed with an insulation system suitable for withstanding voltage of 1.56 kV (peak phase to phase)
and rise time > = 0.5 micro sec.
2) The customer / his system integrator have to ensure that the voltage at motor terminals shall not exceed above limit by properly selecting cable
length and using suitable filters / choke.
3) Switching frequency should not exceed 5.0 kHz.
4) Electrical balance shield cable suitable for VFD operation should be used.
5) Temperature rise by resistance method with VFD supply will be limited to class F.
0 JNS TAG 09.10.2023
Rev No. Prepared By Checked By Date
PERFORMANCE CURVES
3 Phase Squirrel Cage Induction Motor
Customer : AMAN INTERNATIONAL BBL Ref No.: 10168206/10 Quantity : 1 Nos
Consultant : -- Tag Nos. :
--
Project : --
Output (kW)/Poles : 15 / 2P Frame : 160M
Torque & Current Vs Speed Curve
Current Vs Speed at 110% V Current Vs Speed at 100% V
Current Vs Speed at 80% V Torque Vs Speed at 110% V
Torque Vs Speed at 100% V Torque Vs Speed at 80% V
800%
Current in % of FL current & Torque in % of FL torque
700%
600%
500%
400%
300%
200%
100%
0%
0% 20% 40% 60% 80% 100%
% Synchronous speed
/
0 JNS TAG 09.10.2023
18.11.2023 Rev No. Prepared By Checked By Date
18.11.2023
PERFORMANCE CURVES
3 Phase Squirrel Cage Induction Motor
Customer : AMAN INTERNATIONAL BBL Ref No.: 10168206/10 Quantity : 1 Nos
Consultant : -- Tag Nos. :
--
Project : --
Output (kW)/Poles : 15 / 2P Frame : 160M
Efficiency, Power Factor Vs Output Curve
Efficiency Power Factor
100 1.00
90 0.90
80 0.80
Efficiency in %
Power Factor
70 0.70
60 0.60
50 0.50
40 0.40
0% 25% 50% 75% 100%
Output in % of FL
18.11.2023
/
18.11.2023
0 JNS TAG 09.10.2023
Rev No. Prepared By Checked By Date
PERFORMANCE CURVES
3 Phase Squirrel Cage Induction Motor
Customer : AMAN INTERNATIONAL BBL Ref No.: 10168206/10 Quantity : 1 Nos
Consultant : -- Tag Nos. :
--
Project : --
Output (kW)/Poles : 15 / 2P Frame : 160M
Thermal Withstand Time, Starting Time
Vs Current Curve
Cold Condition Hot Condition Starting Time at 80% V
Starting time at 100% V Starting Time at 110%V
At 80% V At 100% V At 110% V
10000
1000
Time in seconds
100
25
16
13
10
13
8 7
1 0.8
0.5
0.4
0
0 100 200 300 400 500 600 700 800
Current in % age of Full Load
/
18.11.2023
0 JNS TAG 09.10.2023
Rev No. Prepared By Checked By Date
18.11.2023
18.11.2023
18.11.2023
SECTION 'A-A'
U2
W1
A
V1 A
M10 FOR JACKING
V2
W2
U1 FILL WITH
COMPOUND
18.11.2023
18.11.2023
TERMINAL BOX ARRANGEMENT
TBAD18LC01
AIROLI, NAVI MUMBAI
Ammeter shall be suitable for
4-20mA Input signal
Peso certificate shall be submitted
18.11.2023
18.11.2023
Page 1 of 3
Government of India
Ministry of Commerce & Industry
Petroleum & Explosives Safety Organisation (PESO)
5th Floor, A-Block, CGO Complex, Seminary Hills,
Nagpur - 440006
E-mail : explosives@explosives.gov.in
Phone/Fax No : 0712 -2510248, Fax-2510577
Approval No : A/P/HQ/MH/104/6532 (P482126) Dated : 01/09/2020
To,
M/s. BHARAT BIJLEE LIMITED,
PlotNo,2,
MIDC,THANE-BELAPUR ROAD,AIROLI,NAVI MUMBAI,
Thane,
Taluka: Thane,
District: THANE,
State: Maharashtra,
PIN: 400708
Sub : Approval of Flame Proof Type 3 Phase Squirrel Cage Induction Motors under Petroleum Rules 2002- Regarding.
Sir(s),
Please refer to your letter No. OIN546519 dated 14/08/2020 on the subject.
The following Ex electrical equipment(s) manufactured by you according to IS/IEC 60079-0 : 2011, IS/IEC 60079-1 :
2014, standards and covered under Central Institute of Mining and Fuel Research Test reports mentioned below
is/are approved for use in Zone 1 of Gas IIB hazardous areas coming under the the Petroleum Rules, 2002
administered by this Organization.
Equipment Test Agency
Sr. No Safety Drawing no
Description reference Certificate
Protection Name Certificate No.
Number Date
FLP 3
Phase
Squirrel
Central 99243
Cage AC
Institute Sheet 1-4
Induction Ex d IIB T6
1 P482126/1 of Mining IN/CIMFR/TR20/H03 14/05/2020 Rev k, 96004
Motor Gb
and Fuel Rev
Frame Size
Research a
MJ80 (IEC
Frame size
80)
FLP 3
Phase
Squirrel
Central 80105
Cage AC
Institute Sheet 1-4
Induction Ex d IIB T5
2 P482126/2 of Mining IN/CIMFR/TR20/754 05/03/2020 Rev g, 71047
Motor Gb
and Fuel Rev
Frame Size
Research a
MJ90 (IEC
Frame size
90L)
18.11.2023
18.11.2023
https://online.peso.gov.in/PesoOnline/onlineApplicaton/OflnPrintLetter.aspx?lType=A... 02-Sep-20
Page 2 of 3
FLP 3
Phase
P482126/3 IN/CIMFR/TR20/736 04/03/2020
Squirrel Central 85202
Cage AC Institute Sheet 1-5
3 Induction Ex d IIb T5 of Mining Rev f,
Motor Gb and Fuel 71047 Rev
Frame Size Research b
MJ100 (IEC
Frame size
100L)
FLP 3
Phase
Squirrel
Central 99012
Cage AC
Institute Sheet 1-4
Induction Ex d IIB T5
4 P482126/4 of Mining IN/CIMFR/TR20/764 06/03/2020 Rev f, 71047
Motor Gb
and Fuel Rev
Frame Size
Research b
MJ112 (IEC
Frame size
112M)
FLP 3
Phase
Squirrel
Central 97015
Cage AC
Institute Sheet 1-5
Induction Ex d IIB T5
5 P482126/5 of Mining IN/CIMFR/TR20/H02 13/05/2020 Rev d, 71047
Motor Gb
and Fuel Rev
Frame Size
Research b
MJ160 (IEC
Frame size
160M/L) 18.11.2023
FLP 3 18.11.2023
Phase
Squirrel
Central 84115
Cage AC
Institute Sheet 1-5
Induction Ex d IIB T5
6 P482126/6 of Mining IN/CIMFR/TR20/H05 14/05/2020 Rev e, 71047
Motor Gb
and Fuel Rev
Frame Size
Research b
MJ180 (IEC
Frame size
180L)
FLP 3
Phase
Squirel
Central D315L001
Cage AC
Institute Sheet 1-5 Rev
Induction Ex d IIB T4
7 P482126/7 of Mining IN/CIMFR/TR20/765 06/03/2020 d, D315SM11
Motor Gb
and Fuel Rev b
Frame Size
Research
MJ315L
(IEC Frame
size 315L)
FLP 3
Phase
Squirrel
Cage AC Central D315SM01
Induction Institute Sheet 1-5 Rev
Ex d IIB T4
8 Motor frame P482126/8 of Mining IN/CIMFR/TR20/H04 14/05/2020 d, D315SM11
Gb
Size and Fuel Rev b
MJ315S/M Research
(IEC Frame
size
315S/M)
This Approval is granted subject to observance of the following conditions:-
https://online.peso.gov.in/PesoOnline/onlineApplicaton/OflnPrintLetter.aspx?lType=A... 02-Sep-20
Page 3 of 3
1)he design and construction of the equipment shall be strictly in accordance with description, condition and drawings as
mentioned in the Test Reports referred to above.
2)he equipment shall be used only with approved type of accessories and associated apparatus.
3) Each equipment shall be marked either by raised lettering cast integrally or by plate attached
permanently to the main structure to indicate conspicuously:-
(a) Name of the manufacturer
(b) Name and number by which the equipment is identified.
(c) Number & date of the test report of the Central Institute of Mining and Fuel Research applicable
to the equipment.
(d) Equipment reference number of this letter by which use of apparatus is approved.
(e) BIS approval number.
(f) Protection level.
4) A certificate to the effect that the equipment has been manufactured strictly in accordance with the drawing referred to
in the Test report and is identical with the one tested and certified at Testing agency shall be furnished with each
equipment.
5) The customer shall be supplied with a copy of this letter, an extract of the conditions and maintenence schedule, if any,
recommended by Central Institute of Mining and Fuel Research and copy of instructions booklet detailing operation &
maintenance of the equipment so as to maintain its safe characterestics.
6) The IS/IEC 60079-17 and IS/IEC 60079-19 shall be followed for maintenance and repair of overhaul of the subject
equipments.
Conditions of the Approval:-
The approval for above motors is subject to validity of BIS License No. CM/L-0366749.
This approval also covers the permissible variations as approved under the Central Institute of
Mining and Fuel Research test reports referred above. This approval is liable to be cancelled if any of
the conditions of the approval is violated or not complied with . The approval may also be amended or
withdrawn at any time, if considered necessary in the interest of safety.
The field performance report from actual users/your customers of the subject equipment may
please be collected and furnished to this office for verification and record on annual basis.
The Approval is Valid upto 31/12/2024
Yours faithfully,
(Ninad Dattaram Gawade)
Dy. Controller of Explosives
For Chief Controller of Explosives
Nagpur
Copy to :
1. Jt. Chief Controller of Explosives, West Circle, MUMBAI
for Chief Controller of Explosives
Nagpur
(For more information regarding status,fees and other details please visit our website http://peso.gov.in)
This is System Generated document. Signature is not required.
18.11.2023
18.11.2023
https://online.peso.gov.in/PesoOnline/onlineApplicaton/OflnPrintLetter.aspx?lType=A... 02-Sep-20