LA-G2

Data Sheet

WWW.KALATEC.COM.BR
13 Other Models

12
Inquiry Table

11
03 Cable Connector

Definition
of Terms
09-10
Contents
Position Feedback
0A
0 72
V 22

80
5G
08
04
Configs. Overall Dimension
Load & Speed

07
Rear Mount. End

05 06
Chart of Load, Speed
and Current Front Mount. End
Definition of Terms

Stroke

ngth
Install. Le

Stainlesss Steel Rod

Zi-Ni Coated Mounting Ends

Aluminum Alloy Top Cap

Power/ Signal Cable

Waterproof Cable Connector

Aluminum Alloy Housing

Manual Override

Stroke How far the rod extends outwards from the body. The difference between fully extended length and fully
retracted length. [Customizable]

Install. Length The fully closed size. [Customizable]

Front Mount. End Optional.

Rear Mount. End Optional.

Mount. Holes Can be rotated by 90°.

Dynamic Force The max force that actuator is able to carry when it is moving.

Selflocking The max force that linear actuator is able to hold when it stops.

Weather Protection IP XX. The first digit: dust protection. The second digit: liquid protection. Please refer to [Table 1].

Duty Cycle Continous working time 'a', rest time 'b'. Duty cycle is a/(a+b)x100%. Please refer to [Table 1].

Speed Include free-load speed and full-load speed.

Hall Sensor Provide pulse signals. Displacement measurement is achieved through pulse counting, and the phase
difference of the waveform can be used to identify the rotation direction of motor. Check [Table 1] to see if it is
available.

Potentiometer Potentiometer is a three-terminal variable resistor with a rotating contact which is used to measure the
displacement of actuators. Check [Table 1] to see if it is available.

Manual Override Can be used to extend or retract the actuator without power for emergency. Check [Table 1] to see if it is
available.

3 13
Configs.

Color ■ Silver □ Black □Customized


Lead Screw ■Acme Screw ■ Ball Screw
Operation Mode □ Electrical ■ Electrical + Manual
Application ■Industrial □Furniture □Medical
Operational Temp. □5 to 40℃ □-10 to 65℃ ■-40 to 65℃
Operating Noise □≤45 dB □≤50 dB ■ ≤65 dB
Stroke Range ■50-600mm ■ 600-1,000mm
Dynamic Load □ ≤1,200N □ ≤2,000N □≤4,000N □ ≤7,000N ■ ≤12,000N □≤20,000N
Duty Cycle □10% □ 20% ■ 25%* □50% □ 100%
Motor Type ■Brushed DC □Stepper Motor □Brushless □Servo Motor
Overload Protection □None □ Clutch ■ Electronic □Thermistor
Weather Protection □IP20 □IP43 □IP54 □ IP65 ■IP66
Position Feedback ■None □ Endstop Signal ■ Hall Sensor ■ Potentiometer □ Encoder ■ Reed Switches
Input Voltage ■12VDC ■24VDC ■36VDC ■48VDC □ 110VAC □220VAC

* Don't exceed four minutes continuous working when with full load and 20℃. ■ Options for DJ805G □Other Models

[ Table 1 ]

Parameters
Fill in code:

② ① ③ ③
Max. Max. Reduction Pitch Speed±10% Max. Stroke Max. Stroke
Dynamic
Self-locking Ratio (mm/s) w/o Pot. with Pot.
Code Load

(N) (N) - (mm) Free Load Full Load (mm) (mm)

 ͳʹ,ͲͲͲ ͳͷ,ͲͲͲ Ͷ͵ǣͳ Ͷ ͸ǤͲ ͶǤͲ ͳ,ͲͲͲ ͳ͹6


 ͳͳ,ͲͲͲ ͳʹ,ͲͲͲ ͵ͳǣͳ Ͷ ͺǤͲ ͷǤʹ ͳ,ͲͲͲ ͳ͹6
 ͹,ͷͲͲ ͻ,ͲͲͲ ʹͳǣͳ Ͷ ͳʹǤͲ ͺǤͲ ͳ,ͲͲͲ ͳ͹6
 ͳͲ,ͲͲͲ ͳʹ,ͲͲͲ Ͷ͵ǣͳ ͺ ͳʹǤͲ ͹ǤͲ ͳ,ͲͲͲ ͵ͷ2
 ͹,ͲͲͲ ͺ,ͲͲͲ ͵ͳǣͳ ͺ ͳ͹ǤͲ ͻǤͷ ͳ,ͲͲͲ ͵ͷ2
ͷ,ͲͲͲ ͸,ͲͲͲ ʹͳǣͳ ͺ ʹͷǤͲ ͳͶǤͲ ͳ,ͲͲͲ ͵ͷ2
͸,ͷͲͲ ͺ,ͲͲͲ Ͷ͵ǣͳ ͳʹ ͳͺǤͷ ͳͳǤͲ ͳ,ͲͲͲ ͷ28
Ͷ,ͷͲͲ ͷ,ͷͲͲ ͵ͳǣͳ ͳʹ ʹͷǤͲ ͳ͵ǤͲ ͳ,ͲͲͲ ͷ28
͵,ʹͲͲ Ͷ,ͲͲͲ ʹͳǣͳ ͳʹ ͵͹ǤͲ ʹ͵ǤͲ ͳ,ͲͲͲ ͷ28

[ Table 2 ]

① Measurements are made with actuators in connection with stable power supplies and ambient temperature at 20°C.
② For example, when real load is 10000N, choosing code (D) is fine. Of course, you can also choose (B) or (A) which come with more
load buffer, higher safety factor and longer product service time.
③ There are many factors affecting the "customizable maximum stroke", such as load, speed, force direction, etc., so the real application
scenarios should be considered. If the parameters you required are not listed, please contact our sales engineers.

4 13
Charts Fill in code:

1 α 12v 2 α 24v
/ ,& '    
Ϯϰ͘Ϭ ϭϱ͘Ϭ

    
ϮϬ͘Ϭ ϭϮ͘ϱ
/ , & '
ϭϲ͘Ϭ ϭϬ͘Ϭ
Current (A)

Current (A)
ϭϮ͘Ϭ ϳ͘ϱ 7 20
20
V2
5 G
ϴ͘Ϭ ϱ͘Ϭ
80

ϰ͘Ϭ Ϯ͘ϱ

Ϭ͘Ϭ Ϭ͘Ϭ
Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ
Load (N) Load (N)

3 α 36v 4 α 48v

ϭϱ͘Ϭ ϲ͘Ϭ
/ , & '    

ϭϮ͘ϱ ϱ͘Ϭ

ϭϬ͘Ϭ A ϰ͘Ϭ A
7 20 7 20
20 20
Current (A)
Current (A)

ϳ͘ϱ / ,& V2 


'    ϯ͘Ϭ V2
G G
8 05 8 05
ϱ͘Ϭ Ϯ͘Ϭ

Ϯ͘ϱ ϭ͘Ϭ

Ϭ͘Ϭ Ϭ͘Ϭ
Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ

Load (N) Load (N)

ϰϮ͘Ϭ

ϯϱ͘Ϭ

Ϯϴ͘Ϭ
Speed (mm/s)

/
Ϯϭ͘Ϭ

ϭϰ͘Ϭ &
, '



ϳ͘Ϭ  

Ϭ͘Ϭ
Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ

Load (N)

* Measurements are made with actuators in connection with stable power supplies and ambient temperature at 20°C.

5 13
Front Mounting End

1. Please contact our sales team if none of the options below meet your requirements. Fill in code:

F01 F02 F03 F04


×

F05 F06 F07 F08

A
7 20
20
V2
5 G
80

F09

2. Start of Installation Length 3. Hole Direction Fill in code:

1 = 90° 2 = 0°

6 13
Rear Mounting End

1. Please contact our sales team if none of the options below meet your requirements. Fill in code:

27

R01 R02 R03 R04

27 28

R05 R06 R07

2. End of Installation Length 3. Hole Direction Fill in code:

1 = 90° 2 = 0°

7 13
Overall Dimension S= mm, L = mm

A. Mounting Ends VS Install. Length B . Stroke VS Install. Length

Rear Mount. Ends Stroke (S) Install. Length (L)


(mm) (mm)

R01, R02,
Front Mount. Ends 50 - 299 +0
R03, R04
R05, R06,
300 - 599 + 50
R07

≥ 600 + 100

[Table 4]
F01, F02,
F03, F04,
A≥ S+200 mm
F05, F06, (min. 315)
F07
How to calculate 'Install. Length' ?
S = Stroke, L = Install Length, L ≥ A + B

Example
A≥ S+250 mm Front Rear S A B L≥A+B
F08, F09 (min. 340) Mount. Mount. (mm) (mm) (mm) (mm)

F08 R01 50 340 +0 ≥340

[Table 3] [Table 5]

8 13
Signal Feedback Fill in code: 0 = None
1 = Hall Effect Sensor
2 = Potentiometer
3 = Reed Switches
1. Hall Effect Sensor

Option 'A' (Standard) Option 'B'


Dual-sensor, Monitor gear box Dual-sensor, Monitor motor rotation

Equivalent Equivalent
Gear Ratio (pulse/mm) Gear Ratio (pulse/mm)
Code Pitch Code Pitch
4 Pole Pairs 4 Pole Pairs
Actuator Sensor 1 Pole Pair Actuator 1 Pole Pair
(standard) (standard)
A 43.404:1 16:58 0.906 3.625 A 43.404:1 10.851 43.404
B 31.131:1 20:54 4 0.675 2.700 B 31.131:1 4 7.783 31.131
C 20.843:1 27:47 0.435 1.741 C 20.843:1 5.211 20.843
D 43.404:1 16:58 0.453 1.813 D 43.404:1 5.426 21.702
E 31.131:1 20:54 8 0.338 1.350 E 31.131:1 8 3.891 15.566
F 20.843:1 27:47 0.218 0.870 F 20.843:1 2.605 10.422
G 43.404:1 16:58 0.302 1.209 G 43.404:1 3.617 14.468
H 31.131:1 20:54 12 0.225 0.900 H 31.131:1 12 2.594 10.377
I 20.843:1 27:47 0.145 0.580 I 20.843:1 1.737 6.948

[Table 6] [Table 7]

Option 'A' (Standard) Option 'B'


Red
Red F01 100 5V to 15V
F01 100 5V to 15V S1 R12
4.7K
U01 1 V Yellow
1 2 Yellow
2 O 3
V H1 R11 1K Hall 1 G R11 Hall 1
C2 C1 1K
SS41
S2 R22
1
10u 0.1u
4 H2 3 White V 10K White
G 2 O 3
R21 1K Hall 2 G R21 Hall 2
TLE4966 Black 1K Black
SS41
GND 0V GND 0V

Option 'A' (Standard) Option 'B'

0A
0 72
V 22
G
05

9 13
2. Potentiometer

Signal Wires Internal Motor Wiring

Yellow Voltage In Red


M

Red Voltage Out


Black

White Ground COM NC NC COM

2 Red - Slider
Code Max. Stroke Resistance Value per mm 1 White - Home
3 Yellow - End
A, B, C 176 mm 0.0568 K¡
D, E, F 352 mm 0.0284 K¡
Connect 1+2, resistance value
G, H, I 528 mm 0.0189 K¡ increase, actuator extend.
* Start value 0.2~0.4K
[Table 8]

3. Reed switch
Standard N.O. contact. Optional N.C. contact.

10 13
Control & Connector Fill in code: 0 = 2-core bared wires
1 = Logic level control
2 = Go with SK control
S = Synchronized control
X = Custom

1 = Logic level control 2 = Go with SK523 control

Wiring Diagram

Color -
Pendant Remote
Blue, Red Extend (SK523)
Blue, Yellow Retract
HB

Blue
Red
Yellow

Red + Red +
Black - Black -

S = Synchronized control (2-4 actuators)

Channel 1 Channel 2 Channel 3 Channel 4

Junction Box
Red +
Pendant Remote
Black -
(SK523S)

11 13
Inquiry Table

RESET

Voltage 1 = 12V 2 = 24V 3 = 36V 4 = 48V

Load & Speed See [Table 2]

Stroke (mm) Please contact us if the stroke you required is out of range.

Install. Size (mm) See Table [3] and [4]

Front Mount. End F01 - F09 FX = Custom

Rear Mount. End R01 - R07 RX = Custom

Mount. Hole Direction Front 1 = 90° 2 = 0° Rear 1 = 90° 2 = 0°

Signal Feedback 0 = None 1 = Hall Sensor 2 = Potentiometer 3 = Reed Switches

Cable Length 1 = 600 mm 2 = 1000 mm 3 = 1500 mm 4 = 2000 mm X = Custom

Connector 0 = 2-core bared wires S = Synchronized control


1 = Logic level control
2 = Go with SK control X = Custom

Working Temperture 1 = -40℃ to 65℃

Working Frequency Estimated cycles work per day

Indoor or outdoor, end use (Understand your application could help facilitate a good solution.)
Application

End Use

Company
Your Contact Name
Tel. Email

12 13
 You may also be interested in...

Model Load Stroke Speed Install.Length Overall Size IP rate Application


(N) (mm) (mm/s) (mm) (mm)

LA-E29
(Track) 1,500 50-600 16-32 155 155 x 77.4 x L IP20 Furniture

Furniture
LA-L6 3,000 50-600 5.0-15 S+155 148.5 x 80 x L IP66 Medical Care

Furniture
LA-L9 6,000 50-600 5.0-32 S+150 156 x 83 x L IP66
Medical Care

Furniture
LA-L18 8,000 50-600 4.7-28 S+175 156 x 83 x L IP66
Medical Care

Furniture
LA-28 10,000 50-600 5.0-16 S+175 166 x 91 x x IP66
Medical Care

LA-Q 1,200 50-600 5.5-80 S+105 40 x 75 x L IP66 Industrial

LA-J 2,000 50-600 5.0-55 S+108 45 x 77.5 x L IP66 Industrial

Furniture
LA-J2 2,000 50-600 6-15 S+115 43 x 84.5 x L IP66 Medical Care
Industrial
Furniture
LA-J6 2,500 50-600 2.5-22 S+120 64.5 x 102 x L IP66 Medical Care
Industrial

LA-J6-P 1,000 50-600 25-50 S+140 64.5 x 102 x L IP66 Industrial

LA-33 4,000 50-600 5.5-35 S+200 76 x 151 x L IP66 Industrial

LA-33P 7,000 50-600 5.5-35 S+200 76 x 151 x L IP66 Industrial

LA-C 7,000 50-600 5.5-35 S+250 77 x 151 x L IP66 Industrial

* LA-G2 12,000 50-1,000 25-100 S+200 102 x 154 x L IP66 Industrial

LA-JL-01 20,000 50-1,000 5.5-35 S+600 N/A IP66 Industrial