03 Cable Connector
Definition
of Terms
09-10
Contents
Position Feedback
0A
0 72
V 22
80
5G
08
04
Configs. Overall Dimension
Load & Speed
07
Rear Mount. End
05 06
Chart of Load, Speed
and Current Front Mount. End
Definition of Terms
Stroke
ngth
Install. Le
Manual Override
Stroke How far the rod extends outwards from the body. The difference between fully extended length and fully
retracted length. [Customizable]
Dynamic Force The max force that actuator is able to carry when it is moving.
Selflocking The max force that linear actuator is able to hold when it stops.
Weather Protection IP XX. The first digit: dust protection. The second digit: liquid protection. Please refer to [Table 1].
Duty Cycle Continous working time 'a', rest time 'b'. Duty cycle is a/(a+b)x100%. Please refer to [Table 1].
Hall Sensor Provide pulse signals. Displacement measurement is achieved through pulse counting, and the phase
difference of the waveform can be used to identify the rotation direction of motor. Check [Table 1] to see if it is
available.
Potentiometer Potentiometer is a three-terminal variable resistor with a rotating contact which is used to measure the
displacement of actuators. Check [Table 1] to see if it is available.
Manual Override Can be used to extend or retract the actuator without power for emergency. Check [Table 1] to see if it is
available.
3 13
Configs.
* Don't exceed four minutes continuous working when with full load and 20℃. ■ Options for DJ805G □Other Models
[ Table 1 ]
Parameters
Fill in code:
② ① ③ ③
Max. Max. Reduction Pitch Speed±10% Max. Stroke Max. Stroke
Dynamic
Self-locking Ratio (mm/s) w/o Pot. with Pot.
Code Load
[ Table 2 ]
① Measurements are made with actuators in connection with stable power supplies and ambient temperature at 20°C.
② For example, when real load is 10000N, choosing code (D) is fine. Of course, you can also choose (B) or (A) which come with more
load buffer, higher safety factor and longer product service time.
③ There are many factors affecting the "customizable maximum stroke", such as load, speed, force direction, etc., so the real application
scenarios should be considered. If the parameters you required are not listed, please contact our sales engineers.
4 13
Charts Fill in code:
1 α 12v 2 α 24v
/ ,& '
Ϯϰ͘Ϭ ϭϱ͘Ϭ
ϮϬ͘Ϭ ϭϮ͘ϱ
/ , & '
ϭϲ͘Ϭ ϭϬ͘Ϭ
Current (A)
Current (A)
ϭϮ͘Ϭ ϳ͘ϱ 7 20
20
V2
5 G
ϴ͘Ϭ ϱ͘Ϭ
80
ϰ͘Ϭ Ϯ͘ϱ
Ϭ͘Ϭ Ϭ͘Ϭ
Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ
Load (N) Load (N)
3 α 36v 4 α 48v
ϭϱ͘Ϭ ϲ͘Ϭ
/ , & '
ϭϮ͘ϱ ϱ͘Ϭ
ϭϬ͘Ϭ A ϰ͘Ϭ A
7 20 7 20
20 20
Current (A)
Current (A)
Ϯ͘ϱ ϭ͘Ϭ
Ϭ͘Ϭ Ϭ͘Ϭ
Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ
ϰϮ͘Ϭ
ϯϱ͘Ϭ
Ϯϴ͘Ϭ
Speed (mm/s)
/
Ϯϭ͘Ϭ
ϭϰ͘Ϭ &
, '
ϳ͘Ϭ
Ϭ͘Ϭ
Ϭ Ϯ͕ϬϬϬ ϰ͕ϬϬϬ ϲ͕ϬϬϬ ϴ͕ϬϬϬ ϭϬ͕ϬϬϬ ϭϮ͕ϬϬϬ
Load (N)
* Measurements are made with actuators in connection with stable power supplies and ambient temperature at 20°C.
5 13
Front Mounting End
1. Please contact our sales team if none of the options below meet your requirements. Fill in code:
A
7 20
20
V2
5 G
80
F09
1 = 90° 2 = 0°
6 13
Rear Mounting End
1. Please contact our sales team if none of the options below meet your requirements. Fill in code:
27
27 28
1 = 90° 2 = 0°
7 13
Overall Dimension S= mm, L = mm
R01, R02,
Front Mount. Ends 50 - 299 +0
R03, R04
R05, R06,
300 - 599 + 50
R07
≥ 600 + 100
[Table 4]
F01, F02,
F03, F04,
A≥ S+200 mm
F05, F06, (min. 315)
F07
How to calculate 'Install. Length' ?
S = Stroke, L = Install Length, L ≥ A + B
Example
A≥ S+250 mm Front Rear S A B L≥A+B
F08, F09 (min. 340) Mount. Mount. (mm) (mm) (mm) (mm)
[Table 3] [Table 5]
8 13
Signal Feedback Fill in code: 0 = None
1 = Hall Effect Sensor
2 = Potentiometer
3 = Reed Switches
1. Hall Effect Sensor
Equivalent Equivalent
Gear Ratio (pulse/mm) Gear Ratio (pulse/mm)
Code Pitch Code Pitch
4 Pole Pairs 4 Pole Pairs
Actuator Sensor 1 Pole Pair Actuator 1 Pole Pair
(standard) (standard)
A 43.404:1 16:58 0.906 3.625 A 43.404:1 10.851 43.404
B 31.131:1 20:54 4 0.675 2.700 B 31.131:1 4 7.783 31.131
C 20.843:1 27:47 0.435 1.741 C 20.843:1 5.211 20.843
D 43.404:1 16:58 0.453 1.813 D 43.404:1 5.426 21.702
E 31.131:1 20:54 8 0.338 1.350 E 31.131:1 8 3.891 15.566
F 20.843:1 27:47 0.218 0.870 F 20.843:1 2.605 10.422
G 43.404:1 16:58 0.302 1.209 G 43.404:1 3.617 14.468
H 31.131:1 20:54 12 0.225 0.900 H 31.131:1 12 2.594 10.377
I 20.843:1 27:47 0.145 0.580 I 20.843:1 1.737 6.948
[Table 6] [Table 7]
0A
0 72
V 22
G
05
9 13
2. Potentiometer
2 Red - Slider
Code Max. Stroke Resistance Value per mm 1 White - Home
3 Yellow - End
A, B, C 176 mm 0.0568 K¡
D, E, F 352 mm 0.0284 K¡
Connect 1+2, resistance value
G, H, I 528 mm 0.0189 K¡ increase, actuator extend.
* Start value 0.2~0.4K
[Table 8]
3. Reed switch
Standard N.O. contact. Optional N.C. contact.
10 13
Control & Connector Fill in code: 0 = 2-core bared wires
1 = Logic level control
2 = Go with SK control
S = Synchronized control
X = Custom
Wiring Diagram
Color -
Pendant Remote
Blue, Red Extend (SK523)
Blue, Yellow Retract
HB
Blue
Red
Yellow
Red + Red +
Black - Black -
Junction Box
Red +
Pendant Remote
Black -
(SK523S)
11 13
Inquiry Table
RESET
Stroke (mm) Please contact us if the stroke you required is out of range.
Indoor or outdoor, end use (Understand your application could help facilitate a good solution.)
Application
End Use
Company
Your Contact Name
Tel. Email
12 13
You may also be interested in...
LA-E29
(Track) 1,500 50-600 16-32 155 155 x 77.4 x L IP20 Furniture
Furniture
LA-L6 3,000 50-600 5.0-15 S+155 148.5 x 80 x L IP66 Medical Care
Furniture
LA-L9 6,000 50-600 5.0-32 S+150 156 x 83 x L IP66
Medical Care
Furniture
LA-L18 8,000 50-600 4.7-28 S+175 156 x 83 x L IP66
Medical Care
Furniture
LA-28 10,000 50-600 5.0-16 S+175 166 x 91 x x IP66
Medical Care
Furniture
LA-J2 2,000 50-600 6-15 S+115 43 x 84.5 x L IP66 Medical Care
Industrial
Furniture
LA-J6 2,500 50-600 2.5-22 S+120 64.5 x 102 x L IP66 Medical Care
Industrial
WWW.KALATEC.COM.BR