APPROVAL SHEET
承 认 书
Customer
客户名称
Part NO.
产品型号
Mode: Transmissive type .Normally white.
Product type
TFT LCD Module
产品内容
LCD Module: Graphic 1024RGB*600Dot-matrix
Remarks □APPROVAL FOR SEPCIFICATIONS ONLY
备注栏 ■APPROVAL FOR SEPCIFICATIONS AND SAMPLE
Signature by Customer:
客户确认签章
Approved by
Issued by Checked by
PD QA
Page 1 of 13 Rev. A0 2016-12-16
1. PHYSICAL DATA
Item Contents Unit
LCD type TFT TRANSMISSIVE ---
Viewing direction 6 o’clock
Module size (W×H×T) 210.7× 126.4 × 3.5 mm
3
Active area(W×H) 196.61×114.15 mm2
Number of dots(W×H) 1024*RGB* × 600 dots
Pixel Pitch(W×H)) 0.192×0.192 mm
Colors 16M ---
Backlight Type 24 white leds 9.6V /160mA ---
Interface Type RGB ---
2. BLOCK DIAGRAM
VDD GATE DRIVER
GND
AVDD
SOURCE DRIVER
VGH
VGL
VCOM
LCD PANEL 9"
MODE
R0~R7
G0~G7
B0~B7
DCLK
DISP
HSYNC
VSYNC
DE
U/D
L/R
LED+
WHITE LED BACKLIGHT
LED-
Page 2 of 13 Rev. A0 2016-12-16
NO. Pin name NO. Pin name
1 A1 33 R2
2 A2 34 R1
3 K1 35 R0
4 K2 36 GND
5 GND 37 DCLK
6 VCOM 38 GND
7 DVDD 39 L/R
8 MODE 40 U/D
9 DE 41 VGH
10 VS 42 VGL
Page 3 of 13
11 HS 43 AVDD
12 B7 44 RESET
BOE 13 B6 45 NC
14 B5 46 VCOM
TFT 9 INCH
1024*RGB*600
15 B4 47 DITHB
3.Mechanical dimension
Rev. A0
16 B3 48 GND
LCD AA
CENTER
17 B2 49 NC
18 B1 50 NC
19 B0
20 G7
21 G6
22 G5
23 G4
2016-12-16
AK 24 G3
25 G2
26 G1
50 1
1 50
27 G0
28 R7
29 R6
30 R5
31 R4
32 R3
* Unspecified Tolerances is: ±0.2
Back light circuit diagram:
Note:
LCD TYPE 9 inch TFT Transmissive
DISPLAY MODE Normally white
VIEW DIRECTION 6 O'clock
3x8=24 leds
OPERATING TEMP. -20°C ~ 70°C
STORAGE TEMP. -30°C ~ 80°C
BACK LIGHT 24 White leds
BL voltage/current 9.6V / 160mA
ALL MATERIALS MUST BE ROHS COMPLIAN
4. Pin Descriptions
Pin No. Symbol Functional
1 LED A LED Anode
2 LED A LED Anode
3 LED K LED Cathode
4 LED K LED Cathode
5 GND Digital Ground
6 VCOM For external VCOM DC input
7 DVDD Digital Power
DE/SYNC mode select
8 MODE MODE=H: DE mode( normally pull high)
MODE=L: HSD/VSD mode
9 DE Data enable signal
10 VSYNC Vertical sync input.Negative polarity
11 HSYNC Horizontal sync input.Negative polarity
12~19 B7~B0 Blue data Input
20~27 G7~G0 Green data Input
28~35 R7~R0 Red data Input
36 GND Digital Ground
37 DCLK Clock input
38 GND Digital Ground
Source right or left sequence control
39 L/R SHLR=H: right shift, Left → Right
SHLR=L: left right, Right → Left
Gate up or down scan control
40 U/D UPDN=H: up shift, Down → Up
UPDN=L: down shift, Up → Down
41 VGH Positive Power for TFT
42 VGL Negative Power for TFT
43 AVDD Analog Power
Global reset pin.Active low to enter reset state
44 RSTB Suggest to connecting with an RC reset circuit for stability.
Normally pull high.(RC circuit :R=10KΩ,C=1uF))
45 NC Not connect
46 VCOM For external VCOM DC input
47 DITHB Dithering setting
48 GND Digital Ground
49 NC Not connect
50 NC Not connect
Page 4 of 13 Rev. A0 2016-12-16
5. ABSOLUTE MAXIMUM RATINGS
5.1 (GND=AGND=0V)
Parameter Symbol Min Max Unit
Power supply1 VDD -0.6 +3.6 V
Power supply2 Avdd -0.5 +13.5 V
Operating temperature TOPR -20 70 ℃
Storage temperature TSTG -30 80 ℃
5.2 Input driver voltage for LCD
parameter Typ Unit remark
VGH 18 V
VGL -6 V
Temperature:25 ℃ ±2
AVDD 9.6 V
VCOM 3.75 V
Vcom 仅供参考,按客户主板实际情况作微调至不闪
6. Timing characteristics
Page 5 of 13 Rev. A0 2016-12-16
7. RGB MODE DATA INPUT
Page 6 of 13 Rev. A0 2016-12-16
8. Resolution 1024x600
9. Backlight Characteristic
Item Symbol Min Typical Max Unit
LED module Forward voltage VLED B B -- 9.6 --- V
LED module current ILED
B B -- 160 -- mA
L/G Surface Luminance ★1 LS B B -- tbd -- mcd
LCM Surface brightness uniform ★2 LD B B 80 -- -- %
★ 1 Test condition is:
(a) Center point on active area.
(b)Best Contrast.
Page 7 of 13 Rev. A0 2016-12-16
★2 Uniform measure condition:
(1)Measure 9 point. Measure location show below;
(2)Uniform=(Min. brightness /Max. brightness)*100%
(3)Best Contrast.
10.Electro-optical Characteristics
Symbol
Parameter Condition Min. Max. Remark
Typ. Unit
φ3 60 70 Deg.
Hor.
φ9 60 70 Deg.
Viewing angle range CR≥10 Note 3
φ12 40 50 Deg.
Ver.
φ6 60 70 Deg.
Color gamut(C light) 60 %
Luminance Contrast ratio T(%) φ0° 500 Note 4
Temp=25°
Response Time TRT 25 ms Note 2
C
●For panel only
●Electro-Optical Characteristics Test Method
Page 8 of 13 Rev. A0 2016-12-16
.Note2.Definition of Optical Response Time:
.Note3.Definition of Viewing Angleθandφ:
Page 9 of 13 Rev. A0 2016-12-16
Note4.Definition of Contrast ratio (CR):
11. Reliability
11.1 Mtbf
The LCD module shall be designed to meet a minimum MTBF value of 50000 hours with normal
11.2 Test condition
NO. ITEM CONDITION CRITERION
1 High Temperature Non-Operating Test 80℃*240Hrs 。 No Defect Of
2 Low Temperature Non-Operating Test -30℃*240Hrs Operational
3 High Temperature/Humidity Non Operating Test 60℃*90%RH*240Hrs Function In Room
4 High Temperature Operating Test 70℃*240Hrs Temperature Are
5 Low Temperature Operating Test -20℃*240Hrs Allowable
。 IDD of LCM in
Pre-and
-20 ℃ (30Min) Q70 ℃ (30Min)
6 Thermal Shock Test Post-Test Should
*10CYCLES
Follow
Specification
Notes:
1. Judgments should be made after exposure in room temperature for two hours.
2. The distill water is used for the high temperature/humidity test.
3. The sample above is individually for every reliability tests condition.
12. Inspection standards
1.AQL(Acceptable Quality Level
AQL of major and minor defect.
MAJOR DEFECT MINOR DEFECT
AQL 0.65 1.5
Page 10 of 13 Rev. A0 2016-12-16
2. Basic conditions for inspection
The LCM face to us, in normal environment, the lux is 1000±200.(Darkroom’s lux: 100±50),About an
angle of incidence 30,a distance of 30 cm with an angle of 45 degree to check the products without
uncovering the film!
(As shown below)
3.Inspection item and criteria
3.1 LCD appearance defect(View area)
NO Defect item Criteria Remark
Specification Allowable note1:L: Length, W: Width
W≦0.03mm disregard note2: disregard if out of AA
Fiber、glass
0.03mm<W≦0.05mm;
cratch、polarizer 2
1 L≦3.0mm
scratch/folded
0.05mm<W≦0.1mm;
(minor defect) 1
L≦3.0mm
W>0.1mm;L>3.0mm 0
φ≦0.2mm disregard note1: φ=(L+W)/2,L:Length,
Polarizer bubble、
0.2mm<φ≦0.3mm 2 W :Width
2 concave and convex
0.3mm<φ≦0.5mm 1 note2:disregard if out of AA
(minor defect)
0.5mm<φ 0
φ≦0.15mm disregard note2:disregard if out of AA
Black dots、dirty dots、 0.15mm<φ≦0.25mm 2
3 impurities、eye winker 0.25mm<φ≦0.3mm 1
(minor defect)
0.3mm<φ 0
φ≦0.1mm disregard note1: φ=(L+W)/2,L=Length,
Polarizer prick 0.1mm<φ≦0.25mm 3 W=Width
4
(minor defect) note2:the distance between two
φ>0.25mm 0
dots>5mm
Page 11 of 13 Rev. A0 2016-12-16
3.2Electrical criteria
NO Defect item Criteria Remark
1 No display No display
(major defect) 【Reject】
2 Missing line Missing line
(major defect) 【Reject】
3 Seg-com light and dark Seg-com light and dark ND filter 2% test
(major defect) 【Reject】
4 No display in immobility No display in immobility
(major defect) 【Reject】
5 Flicker of Pattern Flicker of Pattern
(major defect) 【Reject】
6 Mura ND filter 2%test
(major defect)
7 Over current Over current
(major defect) 【Reject】
8 Voltage out of specification Voltage out of
(major defect) specification
【Reject】
9 Pattern blur, error code Pattern blur, error code
(major defect) 【Reject】
10 Dark light, Flicker Dark light, Flicker
(major defect) 【Reject】
11 Black/white dots 、 Dirty Specification Allowable Note1:disregard if out of AA
dots、eye winker φ≦0.15mm disregard
(major defect) 0.15mm<φ≦0.25mm 2
0.25mm<φ≦0.3mm 1
0.3mm<φ 0
12 Fiber、glass crutch、Polarizer W≦0.03mm disregard Note1:L: Length, W: Width
scratch/folded 0.03mm<W≦0.0.05mm Note2: disregard if out of AA
2
(major defect) L≤3.0mm
0.05mm<W≦0.1mm
1
L≤3.0mm
W>0.1mm;L>3.0mm 0
Page 12 of 13 Rev. A0 2016-12-16
13.Precautions for using LCD modules.
13.1 Safety
(1)Do mot swallow any liquid crystal ,even if there is no proof that liquid crystal is poisonous.
(2)If the LCD panel breaks, be careful not to get liquid crystal to touch your skin.
(3)If skin is exposed to liquid crystal, wash the area thoroughly with alcohol or soap.
13.2 Storag Conditions
(4)Store the panel or module in a dark place where the temperature is 23±5℃and the humidity is below 45
±20%RH.
(5)Store in anti-static electricity container.
(6)Store in clean environment, free from dust, active gas, and solvent.
(7)Do not place the module near organics solvents or corrosive gases.
(8) )Do not crush, shake, or jolt the module.
13.3Handling Precautions
(9)Avoid static electricity, which can damage the CMOS LSI.
(10)The polarizing plate of the display is very fragile, please handle if very carefully.
(11)Do not give external shock.
(12)DO mot apply excessive force on the surface.
(13)Bo not wipe the polarizing plate with a dry cloth, as it may easily scratch the surface
of plate.
(14)Do not use ketonics solvent & Aromatic solvent, use with a soft cloth soaked with a
cleaning naphtha solvent.
(15)Do not operate it above the absolute maximum rating.
(16)Do not remove the panel or frame from the module.
13.4 Warranty
The period is within twelve months since the date of shipping out under normal using and storage
conditions.
Page 13 of 13 Rev. A0 2016-12-16