1 EC-TYPE EXAMINATION CERTIFICATE

2 Equipment or Protective systems intended for use in Potentially


Explosive Atmospheres - Directive 94/9/EC
3 EC-Type Examination Certificate No: FM09ATEX0024X
4 Equipment or protective system: 2600T Pressure transmitter, Model 266
(Type Reference and Name)

5 Name of Applicant: ABB SpA

6 Address of Applicant: Via Statale 113


Lenno (Como) 22016
Italy
7 This equipment or protective system and any acceptable variation thereto is specified in the schedule to this
certificate and documents therein referred to.

8 FM Approvals Ltd, notified body number 1725 in accordance with Article 9 of Directive 94/9/EC of 23 March
1994, certifies that this equipment has been found to comply with the Essential Health and Safety Requirements
relating to the design and construction of equipment intended for use in potentially explosive atmospheres given
in Annex II to the Directive.

The examination and test results are recorded in confidential report number:

3030281EC dated 23rd July 2009

9 Compliance with the Essential Health and Safety Requirements, with the exception of those identified in item 15
of the schedule to this certificate, has been assessed by compliance with the following documents:

EN 60079-0: 2006, EN 60079-11:2007, EN 60079-26:2004, EN 60079-27: 2006, EN 61241-0: 2006,


EN61241-11:2006, and EN 60529: 1991 + A1: 2000
10 If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to special
conditions for safe use specified in the schedule to this certificate.

11 This EC-Type Examination certificate relates only to the design, examination and tests of the specified
equipment or protective system in accordance to the directive 94/9/EC. Further requirements of the Directive
apply to the manufacturing process and supply of this equipment or protective system. These are not covered by
this certificate.

12 The marking of the equipment or protective system shall include:


II 1 G Ex ia IIC T* Entity (For communication option 1, 7, 8, H, L, T); IP67
II 1 G Ex ia IIC T* FISCO (For communication option 2, 3, F, P); IP67
II 1/2 G Ex ia IIC T* Entity (For communication option 1, 7, 8, H, L, T); IP67
II 1/2 G Ex ia IIC T* FISCO (For communication option 2, 3, F, P); IP67

II 1 D Ex iaD 20 T85°C: IP67


II 1/2 D Ex iaD 21 T85°C: IP67

* See Description of Equipment or Protective System for the temperature class

Digitally signed by Mick Gower


DN: cn=Mick Gower, o=FM Approvals, ou,
email=mick.gower@fmapprovals.com,
c=GB
Date: 2012.10.19 11:14:51 +01'00'

Mick Gower
Certification Manager, FM Approvals Ltd.

Issue date: 19th October 2012

THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: atex@fmapprovals.com www.fmapprovals.com

F ATEX 020 (May/12) Page 1 of 7


SCHEDULE
to EC-Type Examination Certificate No. FM09ATEX0024X

13 Description of Equipment or Protective System:

The 2600T Pressure transmitter, Model 266 consists of an aluminium alloy or stainless steel housing
with an internal partition which separates the enclosure into a terminal compartment and an
electronics compartment. RF leadthroughs are fitted in the partition wall. The terminal compartment
is fitted with a flat threaded cover and the electronics compartment is fitted with a window cover
having a cemented-in flat glass window. The housing is also provided with a threaded opening on
the electronics side to accommodate a pressure sensor (primary) which can be of gauge or
differential design and having various sensor types. All joints are sealed using ‘O’ rings and all
threaded joints are locked against removal.

The enclosure body has 2 threaded conduit entries and the threads are either M20 x 1.5 or ½ inch
NPT.

The various options are as follows:

266bcdefgh1h2imnoqrstu 2600T Series Pressure Transmitter model 266.


Ex ia IIC T* - DH3173; Entity (For communication option 1, 7, 8, H, L, T); IP67
Ex ia IIC T* - DH3173; Entity (For communication option 1, 7, 8, H, L, T); IP67
Ex iaD T85°C - DH3173; IP67
Ex iaD T85°C - DH3173:IP67

Electrical parameters
*HART/Entity
Ui = 30 Vdc Ci = 5 nF Li = 10 uH
Ui = 30 Vdc Ci = 17 nF Li = 10 uH when option u = YE

T Class Minimum Maximum Imax Power


Ambient Ambient mA W
°C °C
T4 -50°C +85°C 100 0.75
T4 -50°C +70°C 160 1
T5 -50°C +40°C 100 1.75
T6 -50°C +40°C 50 0.4

*Profibus/Fieldbus
Ui = 17.5V Ii = 360 mA Pi = 2.5 W Ci = 5nF Li = 10 uH
T Class Minimum Ambient Maximum
°C Ambient
°C
T4 -50°C +85°C
T5 -50°C +40°C
T6 -50°C +40°C

THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: atex@fmapprovals.com www.fmapprovals.com

F ATEX 020 (May/12) Page 2 of 7


SCHEDULE
to EC-Type Examination Certificate No. FM09ATEX0024X

*FISCO
Ui = 17.5V Ii = 380 mA Pi = 5.32 W Ci = 5nF Li = 10 uH
T Class Minimum Ambient Maximum
°C Ambient
°C
T4 -50°C +85°C
T5 -50°C +40°C
T6 -50°C +40°C

b = measure type and construction: A, C, D, G, H, J, M, N, P, R, or V.


c = application: D**, H, L, R**, S or V.
d = performance: H, T.
e = upper range limits: A, B, C, D, E, F, G, H, L, M, N, P, Q, R, S, U, V or Z.
f = static pressure range: 1, 2, 3, 4, C, H, M, S, W, Y, or Z.
g = transducer diaphragm material and fill fluid : 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F, G, H, I,
J, K, L, M, N, P, Q, R, S, T, V, W, Y, or Z.
h1 = differential process flanges material & connection : 1, 2, 3, A, B, C, D, E, F, G, H, L, M, P, Q,
R, S, T, U, V, Z, Y or W.
h2 = gauge connection material and type : 1, 2, 3, A, B, C, D, E, F, H, K, M, N, P, Q, R, S, T, U,
V, or Y.
i = gasket: 5, 6, 8 or N.
m (only for 266 DLH and 266 DHH) = high pressure side process flange standard rating – size :
A, B, D, E, M, N, or L.
n (only for 266 DLH and 266 DHH) = high pressure side process flange material-form-finish : A,
D, G, or L.
o (only for 266 DLH and 266 DHH) = low pressure side diaphragm material and fill fluid : 4, 5, A,
B, C, D, F, H, K, L, M, P, Q, S, or T.
q (only for 266 DLH) = low pressure side seal type and capillary length : 1, 2, 3, 4, 5, 6, 7, 8, M,
N, Q, S, T, U, V, or Z.
r = bolts and gasket: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, C, N, R, T, or S.
s = electronic housing: A, B, E, G, J, K, S, T, W, or Z.
t = communication: 1, 2, 3, 7, 8, F, H, L, P, or T. (If t = F, P, H, L or T then u = blank)
u = Options: Blank, or A1, A4, A5, A6, A7, A8, A9, B1, B2, B3, B4, B5, C1, C3, C4, C5, C6, C9,
CC, CG, CT, D2, E1, E7, EN, EW, H1, H3, H4, I1, I2, L1, L3, L5, L9, M1, M2, M3, M4, M5, M6,
M7, M8, M9, MA, MB, N1, N2, N3, N4, N5, N6, P1, P2, P3, P4, P5, R1, S2, T1, T2, T3, T4, T5,
T6, T7, T8, T9, TA, TB, U1, U2, U3, U4, U5, U6, U7, U8 V1, V2, V3, V4, V5, V6, V7, V8, V9, VA,
VB, VC, YA, YB, YC, YD, YE or Z1.

** Note 1:If on option “c” is D or R denotes remote seal elements.


Code of remote seal :
S6 for 600TEN series
S26 for 2600T series

THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: atex@fmapprovals.com www.fmapprovals.com

F ATEX 020 (May/12) Page 3 of 7


SCHEDULE
to EC-Type Examination Certificate No. FM09ATEX0024X

266bcdefgh1h2imnoqrstu 2600T Series Pressure Transmitter model 266 (multivariable).


Ex ia IIC T* - DH3173; Entity ; IP67
Ex ia IIC T* - DH3173; Entity ; IP67
Ex iaD T85°C - DH3173; IP67
Ex iaD T85°C - DH3173:IP67

Electrical parameters
*HART/Entity
Ui = 30 Vdc Ci = 13 nF Li = 10 uH

T Class Minimum Maximum Imax Power


Ambient Ambient mA W
°C °C
T4 -50°C +85°C 100 0.75
T4 -50°C +70°C 160 1
T5 -50°C +40°C 100 1.75
T6 -50°C +40°C 50 0.4
b = measure type and construction: A, C, D, G, H, J, M, N, P, R, or V.
c = application: D**, H, L, R**, S or V.
d = performance: H, T.
e = upper range limits: A, B, C, D, E, F, G, H, L, M, N, P, Q, R, S, U, V or Z.
f = static pressure range: 1, 2, 3, 4, C, H, M, S, W, Y, or Z.
g = transducer diaphragm material and fill fluid : 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F, G, H, I,
J, K, L, M, N, P, Q, R, S, T, V, W, Y, or Z.
h1 = differential process flanges material & connection : 1, 2, 3, A, B, C, D, E, F, G, H, L, M, P, Q,
R, S, T, U, V, or Z.
h2 = gauge connection material and type : 1, 2, 3, A, B, C, D, E, F, H, K, M, N, P, Q, R, S, T, U,
V, or Y.
i = gasket: 5, 6, 8 or N.
m (only for 266 DLH and 266 DHH) = high pressure side process flange standard rating – size :
A, B, D, E, M, N, or L.
n (only for 266 DLH and 266 DHH) = high pressure side process flange material-form-finish : A,
D, G, or L.
o (only for 266 DLH and 266 DHH) = low pressure side diaphragm material and fill fluid : 4, 5, A,
B, C, D, F, H, K, L, M, P, Q, S, or T.
q (only for 266 DLH) = low pressure side seal type and capillary length : 1, 2, 3, 4, 5, 6, 7, 8, M,
N, Q, S, T, U, V, or Z.
r = bolts and gasket: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, C, N, R, T, or S.
s = electronic housing: A, B, E, G, J, K, S, T, W, or Z.
t = communication: 1, 8, H, or T. (If t = H, or T then u = blank)
u = Options: Blank, or A1, A4, A5, A6, A7, A8, A9, B1, B2, B3, B4, B5, C1, C3, C4, C5, C6, C9,
CC, CG, CT, E1, E7, EN, EW, H1, H3, H4, I1, I2, L1, L3, M1, M2, M3, M4, M5, M6, M7, M8, M9,
MA, MB, N1, N2, N3, N4, N5, N6, P1, P2, P3, P4, P5, S2, T1, T2, T3, T4, T5, T6, T7, T8, T9, TA,
TB, U1, U2, U3, U4, U5, U6, U7, U8 V1, V2, V3, V4, V5, V6, V7, V8, V9, VA, VB, VC, YA, YB,
YC, YD, or Z1.
** Note 1:If on option “c” is D or R denotes remote seal elements.
Code of remote seal :
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: atex@fmapprovals.com www.fmapprovals.com

F ATEX 020 (May/12) Page 4 of 7


SCHEDULE
to EC-Type Examination Certificate No. FM09ATEX0024X

S6 for 600TEN series


S26 for 2600T series
266bcdefgh1h2imnoqrstu 2600T Series Pressure Transmitter model 266. (L5 display
option)
Ex ia IIC T* Entity (For communication option 1, 8, H, T); IP67
Ex ia IIC T* FISCO (For communication option 2, 3, F, P); IP67
Ex ia IIC T* Entity (For communication option 1, 8, H, T); IP67
Ex ia IIC T* FISCO (For communication option 2, 3, F, P); IP67
Ex iaD T85°C: IP67
Ex iaD T85°C: IP67
Electrical ratings;

Entity/HART Version
Ui = 30Vdc Ci = 5 nF Li = 10 uH
Ui = 30 Vdc Ci = 17 nF Li = 10 uH when option u = YE

Minimum Maximum
Temperature Temperature Imax Power
ambient ambient
Class - Gas Class - Dust mA W
°C °C
T4 T135°C -50°C +60°C 100 0.75
T4 T135°C -50°C +60°C 160 1
T5 T100°C -50°C +56°C 100 1.75
T6 T85°C -50°C +44°C 50 0.4

Profibus version
Ui = 17.5 Vdc Ii = 360mA Pi = 2.52W Ci = 5 nF Li = 10 uH
Temperature Class Temperature Class minimum ambient maximum ambient
- Gas - Dust °C °C
T4 T135°C -50°C +60°C
T5 T100°C -50°C +56°C
T6 T85°C -50°C +44°C

FISCO Version
Ui = 17.5 Vdc Ii = 380mA Pi = 5.32 W Ci = 5 nF Li = 10 uH
Temperature Class Temperature Class minimum ambient maximum ambient
- Gas - Dust °C °C
T4 T135°C -50°C +60°C
T5 T100°C -50°C +56°C
T6 T85°C -50°C +44°C

b = measure type and construction: A, C, D, G, H, J, M, N, P, R, or V.


c = application: D**, H, L, R**, S or V.
d = performance: H, T.
e = upper range limits: A, B, C, D, E, F, G, H, L, M, N, P, Q, R, S, U, V or Z.
f = static pressure range: 1, 2, 3, 4, C, H, M, S, W, Y, or Z.
g = transducer diaphragm material and fill fluid : 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F,
G, H, I, J, K, L, M, N, P, Q, R, S, T, V, W, Y, or Z.
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: atex@fmapprovals.com www.fmapprovals.com

F ATEX 020 (May/12) Page 5 of 7


SCHEDULE
to EC-Type Examination Certificate No. FM09ATEX0024X

h1 = differential process flanges material & connection : 1, 2, 3, A, B, C, D, E, F, G, H, L,


M, P, Q, R, S, T, U, V, or Z.
h2 = gauge connection material and type : 1, 2, 3, A, B, C, D, E, F, H, K, M, N, P, Q, R, S,
T, U, V, or Y.
i = gasket: 5, 6, 8 or N.
m (only for 266 DLH and 266 DHH) = high pressure side process flange standard rating –
size : A, B, D, E, M, N, or L.
n (only for 266 DLH and 266 DHH) = high pressure side process flange material-form-
finish : A, D, G, or L.
o (only for 266 DLH and 266 DHH) = low pressure side diaphragm material and fill fluid :
4, 5, A, B, C, D, F, H, K, L, M, P, Q, S, or T.
q (only for 266 DLH) = low pressure side seal type and capillary length : 1, 2, 3, 4, 5, 6, 7,
8, M, N, Q, S, T, U, V, or Z.
r = bolts and gasket: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, C, N, R, T or S.
s = electronic housing: A, B, E, G, J, K, S, T, W, or Z.
t = communication: 1, 2, 3, 8, F, H, P, or T. (If t = F, P, H, or T then u = blank)
u = Options: Blank, or A1, A4, A5, A6, A7, A8, A9, B1, B2, B3, B4, B5, C1, C3, C4, C5,
C6, C9, CT, E1, E7, EN, EW, H1, H3, H4, I1, I2, L5, M1, M2, M3, M4, M5, M6, M7, M8,
M9, MA, MB, N1, N2, N3, N4, N5, N6, P1, P2, P3, P4, P5, S2, T1, T2, T3, T4, T5, T6, T7,
T8, T9, TA, TB, U1, U2, U3, U4, U5, U6, U7, U8 V1, V2, V3, V4, V5, V6, V7, V8, V9, VA,
VB, VC, YA, YB, YC, YD, YE or Z1.

** Note 1: If option “c” is ‘D’ or ‘R’ this denotes remote seal elements.
Code of remote seal :
S6 for 600TEN series
S26 for 2600T series

14 Special Conditions for Safe Use:


1. 1. When the manufacturer of the equipment has not identified the type of protection on the label, the user
shall, on installation, mark the label with the type of protection used.

15 Essential Health and Safety Requirements:


The relevant EHSRs that have not been addressed by the standards listed in this certificate have been identified
and assessed in the confidential report identified in item 8.

16 Test and Assessment Procedure and Conditions:


This EC-Type Examination Certificate is the result of testing of a sample of the product submitted, in
accordance with the provisions of the relevant specific standard(s), and assessment of supporting
documentation. It does not imply an assessment of the whole production.

Whilst this certificate may be used in support of a manufacturer’s claim for CE Marking, FM Approvals Ltd
accepts no responsibility for the compliance of the equipment against all applicable Directives in all
applications.

This Certificate has been issued in accordance with FM Approvals Ltd’s ATEX Certification Scheme.

17 Schedule Drawings

THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: atex@fmapprovals.com www.fmapprovals.com

F ATEX 020 (May/12) Page 6 of 7


SCHEDULE
to EC-Type Examination Certificate No. FM09ATEX0024X

A list of the significant parts of the technical documentation is annexed to this certificate and a copy has
been kept by the Notified Body.

18 Certificate History
Details of the supplements to this certificate are described below:

Date Description

24th July, 2009 Original Issue.


Supplement 1:
Report Reference: 3030281EC Supplement 1 – 18th March, 2010.
Description of the Change:
1) Changes to the layout for Front End
18th March, 2010 2) Changes on Hart communication board
3) Changes on FF and PA communication board
4) Addition of alternative self adhesive label
5) Removal of Ceramic Isolator in the inductive type pressure sensors

Supplement 2:
th Report Reference: 3030281EC Supplement 2 – 18th January, 2012.
14 May, 2010
Description of the Change:
1) Addition of HMI Type B Touch Key display option L5
Supplement 3:
Report Reference: 3030281EC Supplement 3 – 18 January 2012.
Description of the Change:
30th January 2012 1) Improvement of communication board FF.
2) New sensor for gauge type for ovp 1379 Bar single seal.
3) New second front end for the multivariable version.
4) Replacement of capacitive sensor type with new piezo type.
Supplement 4:
Report Reference: 3030274rev120211 – 14th February, 2012.
Description of the Change:
20th February, 2012 Addition of descriptive drawings for the 1000 Bar versions of the transmitter when
configured as;
1) 1575 Bar for connection type F250C or
2) 1350 Bar for connection type 1/4 - 18 NPT.
Supplement 5:
Report Reference: 3030274rev110203 – 31st May, 2012, 3030274rev120801 – 31st
May, 2012 and 3030274rev120203 – 31st May, 2012.
Description of the Change:
8th June, 2012 1) Modification of the 266 Fieldbus Foundation communication board.
2) Replacement of the capacitive transducer with a new piezo type for low pressure
ranges.
3) Modification of the 266 Multivariable version, with Hart protocol communication.
4) Addition of Extended EMC terminal board option.
Supplement 6:
Report Reference: 3030274rev120116 – 8th October 2012
Description of the Change:
18th October 2012
1) Improvement of model 266 (only inductive type with Hart protocol communication)
2) Modification to nameplate
3) Optional component part for D3 on HART terminal Board.

THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: atex@fmapprovals.com www.fmapprovals.com

F ATEX 020 (May/12) Page 7 of 7


Blueprint Report
ABB SpA (Frmly ABB SACE SpA) (1000002443)
Class No 3610

ABB SpA (Frmly ABB SACE SpA) (1000002443)


Class No 3610
Original Project I.D. 3030281
Certificate I.D. FM09ATEX0024X
Drawing No. Revision Level Drawing Title Last Report Electronic Drawing
0489-702-3-C 1 bare board second front end FM09ATEX0024X Yes (pdf)
0489703-4-C R01 0 bare board second front end FM09ATEX0024X Yes (pdf)
0489703-4-C R02 0 bare board second front end FM09ATEX0024X Yes (pdf)
0489703-4-C R03 0 bare board second front end FM09ATEX0024X Yes (pdf)
0489703-4-C R04 0 bare board second front end FM09ATEX0024X Yes (pdf)
0489703 4 front end p-capacitive type "PCB" FM09ATEX0024X Yes (pdf)
0489707 R02 4 front end p-capacitive type "PCB" FM09ATEX0024X Yes (pdf)
0489707 R03 4 front end p-capacitive type "PCB" FM09ATEX0024X Yes (pdf)
0489707 R04 4 front end p-capacitive type "PCB" FM09ATEX0024X Yes (pdf)
2-6259-3 BS 1 board assembled second front end top FM09ATEX0024X Yes (pdf)
2-6259-3 LS 1 board assembled second front end bottom FM09ATEX0024X Yes (pdf)
2-6259-P1 1 second front end board FM09ATEX0024X Yes (pdf)
2-9185 X1 1 primary transducer P-capacitive FM09ATEX0024X Yes (pdf)
2-9186 X2 3 primary transducer P-piezo 120203 Yes (pdf)
2-9187 X2 1 primary transducer DP-piezo FM09ATEX0024X Yes (pdf)
2-9188 X2 1 primary transducer DP-piezo- HP FM09ATEX0024X Yes (pdf)
3KXP001001U0011 7 Connection board schematic 120116 Yes (pdf)
3KXP001001U0021 5 Connection board Hart “layout” 120116 Yes (pdf)
3KXP001001U0030 d Connection board Hart “BOM”reed 120116 Yes (pdf)
3KXP001001U0031 2 Connection board reed 120116 Yes (pdf)
3KXP001001U0040 d Connec. board Hart “BOM” push 120116 Yes (pdf)
3KXP001001U0041 2 Connection board push 120116 Yes (pdf)
3KXP001001U0060 a Assy Con.board Hart “BOM” reed s 120116 Yes (pdf)
3KXP001001U0090 a Assy Con.board Hart “BOM” push s 120116 Yes (pdf)
3KXP001001U0091 2011-11-17 Ass conn board 120116 Yes (pdf)
480701-2-D 7 front end dp-piezoresistive type "PCB" Supplement 1 Yes (pdf)
480706-2-C 6 front end dp-piezoresistive HP type "PCB" Supplement 1 Yes (pdf)
489700X1 2 Bare Board Common HMI Type B Supplement 2 Yes (pdf)
489705-2-C 6 front end p-piezoresistive type "PCB" Supplement 1 Yes (pdf)
489707 6 front end p-capacitive type "PCB" Supplement 1 Yes (pdf)
632782 1 Label Common HMI Type B Supplement 2 Yes (pdf)

19/10/2012 Page 1 of 4
9280300X1 P1 3 Common HMI Type B with Touch Key Schematic Supplement 2 Yes (pdf)
9280300X1 3 Board Assembled – Common HMI Type B Supplement 2 Yes (pdf)
9280300 24.11.08 Parts List Supplement 2 Yes (pdf)
9280301 2 7 front end dp-piezoresistive type "circuit diagram" Supplement 1 Yes (pdf)
9280301 DP F front end dp-piezoresistive type "part list" Supplement 1 Yes (pub_html)
9280304 3 Common HMI Type B with Touch Key Assembly Supplement 2 Yes (pdf)
9280305 2 6 front end p-piezoresistive type "circuit diagram" Supplement 1 Yes (pdf)
9280305 3 E front end p-piezoresistive type "part list" Supplement 1 Yes (pub_html)
9280306 2 6 front end dp-piezoresistive HP type "circuit diagram" Supplement 1 Yes (pdf)
9280306 DP E front end dp-piezoresistive HP type "part list" Supplement 1 Yes (pub_html)
9280309 2 P1 6 front end p-capacitive type "circuit diagram" Supplement 1 Yes (pdf)
9280309 P CAP E front end p-capacitive type "part list" Supplement 1 Yes (pub_html)
AU 3062 4 front end inductive type "part list" Supplement 3 Yes (pdf)
AU 3063 0 mile2 terminal block hart standard version "part list" FM09ATEX0024X Yes (pdf)
AU 3066 0 mile2 terminal block FF and PA standard version "part list" FM09ATEX0024X Yes (pdf)
AU 3067 0 mile2 terminal block hart standard version + surge "part list" FM09ATEX0024X Yes (pdf)
AU 3068 0 mile2 terminal block FF and PA standard version + surge "part list" FM09ATEX0024X Yes (pdf)
AU 3069 0 mile2 terminal block hart multivariable "part list" FM09ATEX0024X Yes (pdf)
AU 3069 2 mile2 terminal block hart multivariable "part list" 120203 Yes (pdf)
AU 3070 0 mile2 terminal block FF multivariable "part list" FM09ATEX0024X Yes (pdf)
AU 3071 0 mile2 UFTE pressure type FF "part list" FM09ATEX0024X Yes (pdf)
AU 3071 2 mile2 UFTE pressure type FF "part list" 120203 Yes (pdf)
AU 3072 2 mile2 communication board pressure type FF compensed "part list" Supplement 3 Yes (pdf)
AU 3072 3 mile2 communication board pressure type FF compensed "part list" 120203 Yes (pdf)
AU 3073 0 mile2 UHTE pressure type Hart "part list" FM09ATEX0024X Yes (pdf)
AU 3074 0 mile2 communication board pressure type Hart compensed "part list" FM09ATEX0024X Yes (pdf)
AU 3077_2 0 Parts list 266MV : Second Front End Supplement 3 Yes (pdf)
AU 3080 0 mile2 terminal block hart + surge multivariable "part list" FM09ATEX0024X Yes (pdf)
AU 3081 0 mile2 terminal block FF + surge multivariable "part list" FM09ATEX0024X Yes (pdf)
AU 3087 1 mile2 communication board pressure type FF uncompensed "part list" Supplement 3 Yes (pdf)
AU 3087 2 mile2 communication board pressure type FF uncompensed "part list" 120203 Yes (pdf)
AU 3088 0 mile2 communication board pressure type Hart uncompensed "part list" FM09ATEX0024X Yes (pdf)
AU 3097 0 mile2 communication board pressure type PA uncompensed "part list" FM09ATEX0024X Yes (pdf)
AU 3098 0 mile2 communication board pressure type PA compensed "part list" FM09ATEX0024X Yes (pdf)
AU3077 2 266MV Second Front End 120302 Yes (pdf)
AU3110 0 Ext. UHTE : Multivariable - Not Compensated - 120302 Yes (pdf)
AU3111 0 Multivariable Communication Board –Pressure Type- 120302 Yes (pdf)
AU3128 0 Multivariable round Board 120302 Yes (pdf)
AU3159 0 Sensor board “BOM” 120116 Yes (pdf)
AU3166 1 Terminal block for extended EMC 120302 Yes (pdf)
AU3167 0 Indicator HMI “BOM” 120116 Yes (pdf)
DH 0013 2 2600T Series primary transducer differential Tx inductive type Supplement 3 Yes (pdf)

19/10/2012 Page 2 of 4
DH 0014 2 2600T Series primary transducer gauge Tx inductive type Supplement 3 Yes (pdf)
DH 3114 0 mile2 communication board pressure type Hart "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3115 0 front end inductive type "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3116 0 front end inductive type "PCB" FM09ATEX0024X Yes (pdf)
DH 3119 0 mile2 terminal block hart multivariable "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3119 1 mile2 terminal block hart multivariable "circuit diagram" 120203 Yes (pdf)
DH 3130 2 2600T series pressure transmitter barrell Supplement 1 Yes (pdf)
DH 3131 0 mile2 terminal block hart + surge multivariable "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3132 1 mile2 terminal block hart + surge multivariable "PCB" FM09ATEX0024X Yes (pdf)
DH 3133 0 mile2 terminal block FF + surge multivariable "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3134 1 mile2 terminal block FF + surge multivariable "PCB" FM09ATEX0024X Yes (pdf)
DH 3139 2 mile2 terminal block hart multivariable "PCB" FM09ATEX0024X Yes (pdf)
DH 3139 3 mile2 terminal block hart multivariable "PCB" 120203 Yes (pdf)
DH 3142 0 mile2 terminal block hart standard version "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3143 1 mile2 terminal block hart standard version "PCB" FM09ATEX0024X Yes (pdf)
DH 3144 0 mile2 terminal block hart standard version + surge "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3145 1 mile2 terminal block hart standard version + surge "PCB" FM09ATEX0024X Yes (pdf)
DH 3146 0 mile2 terminal block FF and PA standard version + surge "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3147 2 mile2 terminal block FF and PA standard version + surge "PCB" FM09ATEX0024X Yes (pdf)
DH 3148 0 mile2 communication board pressure type FF and PA "circuit diagram" FM09ATEX0024X Yes (pdf)
DH 3149 1 mile2 communication board pressure type FF and PA "PCB" FM09ATEX0024X Yes (pdf)
DH 3151 1 mile2 communication board pressure type Hart "PCB" FM09ATEX0024X Yes (pdf)
DH 3168 5 266 safety plates 120203 Yes (pdf)
DH 3168 6 266 safety plates 120116 Yes (pdf)
DH 3169 2 2600T series pressure transmitter P-DIN Supplement 3 Yes (pdf)
DH 3170 2 2600T series pressure transmitter DP-DIN Supplement 1 Yes (pdf)
DH 3173 0 control drawing FM09ATEX0024X Yes (pdf)
DH 3173 2 control drawing 120203 Yes (pdf)
DH 3182 11-May-10 ATEX Safety Plate for L5 option Supplement 2 Yes (pdf)
DH 3190 0 2600T SERIES PRIMARY TRANSDUCER , GAUGE Tx STRAIN GAUGE type 11-Feb-12 Yes (pdf)
DH 3191 0 2600T SERIES 266 Interface Board 1000 Bar “Circuit Diagram” 11-Feb-12 Yes (pdf)
DH 3192 0 2600T SERIES 266 Interface Board 1000 Bar PCB 11-Feb-12 Yes (pdf)
DH 3193 0 Second front end multivariable Supplement 3 Yes (pdf)
DH 3193 1 Second front end multivariable 120203 Yes (pdf)
DH 3194 0 2600T Series – 266 MV Second Front End Supplement 3 Yes (pdf)
DH 3194 2 2600T Series – 266 MV Second Front End 120203 Yes (pdf)
DH0013_2_1 24/04/12 2600T Series Primary Transducer Gauge Tx Inductive Type (Front end covered by potting) (Flameproof Device for automatic insertion) 120302 Yes (pdf)
DH0013_2_2 24/04/12 2600T Series Primary Transducer Gauge Tx Inductive Type (Front end covered by plastic protection) (Flameproof Device for automatic insertion) 120302 Yes (pdf)
DH3084 2 Indicator HMI “schematic” 120116 Yes (pdf)
DH3091 2 Indicator HMI “layout” 120116 Yes (pdf)
DH3198 04/07/11 2600T Series Primary Transducer Gauge Tx Inductive Type (Front end covered by potting) (Standard Flameproof Device) 120302 Yes (pdf)
DH3199 04/07/11 2600T Series Primary Transducer Gauge Tx Inductive Type (Front end covered by potting) (Flameproof Device for automatic insertion) 120302 Yes (pdf)

19/10/2012 Page 3 of 4
DH3200 04/07/11 2600T Series Primary Transducer Gauge Tx Inductive Type (Front end covered by plastic protection) (Standard Flameproof Device) 120302 Yes (pdf)
DH3201 04/07/11 2600T Series Primary Transducer Gauge Tx Inductive Type (Front end covered by plastic protection) (Flameproof Device for automatic insertion) 120302 Yes (pdf)
DH3212 1 MILE 2 Series: Terminal block for extended EMC 120302 Yes (pdf)
DH3213 1 Terminal block for extended EMC 120302 Yes (pdf)
DH3214 2 Sensor board “layout” 120116 Yes (pdf)
dh3215 0 Sensor board “circuit diagram” 120116 Yes (pdf)