OPzV SERIES-TUBULAR GEL

P-TITLE (2V200Ah)
4OPzV200

CHARACTERISTICS
Item Specifications
Rated Voltage P-RV
2V
Nominal Capacity (25℃) C10,1.80V/cell P-1080
200Ah
Length 103mm P-LENGTH
(4.06inches)
Width P-WIDTH
206mm (8.11inches)
Dimension
Container Height P-HEIGHT
355mm (14.0inches)
Total Height 390mm P-THEIGHT
(15.4inches)
Approx Weight P-GWEIGHT
18.8kg (41.4lbs)
Terminal P-TER
T7-A(M8)
Container Material ABS (UL94 HB or V-0 optional)
Short-circuit current P-SC
1600A
Internal Resistance (25℃) P-IR
Approx 1 mΩ (Fully charged)
Discharge -20~55℃ (-4~131°F)
Operating Temp. Range Charge 0~40℃ (32~104°F)
Storage -20~50℃ (-4~122°F)
Nominal Operating Temp. Range 25±3℃ (77±5°F)
Max.Charging Current (25℃) 0.25C
Standby Use Cycle Use
390±2

Charge voltage (25℃)


372.7±2
355±2

2.23-2.27V/cell 2.40-2.45V/cell
Temp. Coeffcient -3mV/cell/℃ -5mV/cell/℃
40℃ (104°F) 106%
Effect of temp. to Capacity 25℃ (77°F) 100%
0℃ (32°F) 86%
∅18
Self Discharge ≤3% per month at 25°C (77°F)
15.7
2
9.7
103±1

M8

108±1
206±1

T7-A

DISCHARGE TABLE
Constant Current Discharge (Amperes) at 25°C (77°F)
F.V/Time 1h 2h 3h 5h 8h 10h 24h 48h 72h 100h 120h
P-A85
1.85V/cell A851
89.4 A852
60.4 A853
46.4 A855
31.9 A858
22.2 A8510
18.7 A8524
8.90 A8548
4.65 A8572
3.35 A85100
2.54 A85120
2.19
P-A80
1.80V/cell A801
100.2 A802
66.2 A803
50.5 A805
34.4 A808
23.8 A8010
20.0 A8024
9.21 A8048
4.83 A8072
3.47 A80100
2.60 A80120
2.25
P-A75
1.75V/cell A751
104.2 A752
68.5 A753
51.6 A755
35.1 A758
24.2 A7510
20.3 A7524
9.27 A7548
4.94 A7572
3.56 A75100
2.65 A75120
2.28
P-A70
1.70V/cell A701
108.7 A702
70.2 A703
52.6 A705
35.6 A708
24.5 A7010
20.5 A7024
9.42 A7048
5.04 A7072
3.60 A70100
2.69 A70120
2.31
P-A67
1.67V/cell A671
111.6 A672
71.4 A673
53.6 A675
36.2 A678
24.8 A6710
20.8 A6724
9.50 A6748
5.09 A6772
3.63 A67100
2.74 A67120
2.34
P-A60
1.60V/cell A601
113.3 A602
72.5 A603
54.2 A605
36.5 A608
25.0 A6010
20.9 A6024
9.58 A6048
5.15 A6072
3.65 A60100
2.77 A60120
2.37

Constant Power Discharge (Watts/cell) at 25°C (77°F)

F.V/Time 1h 2h 3h 5h 8h 10h 24h 48h 72h 100h 120h


P-B85
1.85V/cell B851
172.5 B852
117.4 B853
90.5 B855
62.3 B858
44.1 B8510
37.3 B8524
17.8 B8548
9.32 B8572
6.72 B85100
5.10 B85120
4.40
P-B80
1.80V/cell B801
193.0 B802
128.4 B803
98.0 B805
66.9 B808
47.1 B8010
39.7 B8024
18.4 B8048
9.66 B8072
6.96 B80100
5.22 B80120
4.52
P-B75
1.75V/cell B751
199.3 B752
131.2 B753
99.7 B755
68.1 B758
47.8 B7510
40.3 B7524
18.5 B7548
9.87 B7572
7.13 B75100
5.32 B75120
4.59
P-B70
1.70V/cell B701
206.1 B702
134.1 B703
101.4 B705
69.2 B708
48.3 B7010
40.7 B7024
18.8 B7048
10.1 B7072
7.20 B70100
5.39 B70120
4.64
P-B67
1.67V/cell B671
210.1 B672
136.4 B673
103.1 B675
69.8 B678
48.8 B6710
41.0 B6724
18.9 B6748
10.1 B6772
7.25 B67100
5.48 B67120
4.70
P-B60
1.60V/cell B601
212.4 B602
137.6 B603
103.7 B605
70.3 B608
49.0 B6010
41.3 B6024
19.0 B6048
10.2 B6072
7.29 B60100
5.53 B60120
4.74
OPzV SERIES-TUBULAR GEL
P-TITLE (2V200Ah)
4OPzV200

APPLICATIONS GENERAL FEATURES STANDARDS

• Float charging applications: • 20 year design life (20℃) • Compliance with IEC 60896,
communication center, telecom • Strong Lead-calcium alloy tubular plate IEC 61427, DIN 40742 standards
basestation, UPS, power station, technology - for longer life in the toughest
electric substation conditions • UL, CE Approved
• Solar and wind energy storage system • Gelled electrolyte for superior thermal
management, long float life • Manufactured in Leoch®IATF 16949,
• Off-grid and bad-grid hybrid sites
ISO 45001, ISO 9001 and ISO 14001
• Proof against deep discharge - greater certified production facilities
long-term energy delivery
• Exceptional cycling performance - 2500+
cycles at 60% Depth of Discharge

Charge Voltage vs Ambient Temperature Curve Temperature Effects in Relation to Capacity


2.50
120
2.45 10HR
Сycle charge voltage
for max. 16 hours 100
2.40
3HR
80
Charge voltage (V/cell)

Capacity(%)

2.35
1HR

2.30 60

2.25 40
Standby voltage +/- 1%
2.20 20

2.15
-20 -10 0 10 20 30 40 50 (℃)
2.10 -4 14 32 50 68 86 104 122 (°F)
-20 -10 0 10 20 30 40 50 (℃)
-4 14 32 50 68 86 104 122 (°F) Battery Temperature
Battery Temperature

Cycle life Self Discharge Characteristics

8000
120
7000

100
Available capacity / %

6000
Number of Cycles

5000 80

4000 60
10℃
30℃ 20℃
3000 40℃
40
2000
20
1000

0 0 5 10 15 20 25
0% 10% 20% 30% 40% 50% 60% 70% 80%

DOD(%) Storage time (months)

Leoch International Technology Ltd. Leoch Batteries Pte Ltd Leoch Battery Corporation Leoch Europe S.A.
www.leoch.com www.leoch.sg www.leochamericas.com www.leoch.eu

Data above is recommended and the picture is only for battery effect display, Leoch reserve the final right of explanation.
© LEOCH. All rights reserved.Trademarks and logos are the property of LEOCH and its affiliates unless otherwise
noted.Subject to revisions without prior notice. E&OE. P-VERSION
Publication No.:LB-4OPzV200-PD-EN-V2.0-20240130

You might also like