Project Name HDS Alternative Page 1/5

Customer Name Awan, Arslan Joint 1


Country United Kingdom 23-09-2024

Leviat Floor Joint Software, Version 1.0


The following calculation determines the capacity of Isedio ArmourJoint Adjustable based on "TR34.4" and "EC-
2"calculation method.While other products might have similar shape and properties their performance can vary so that this
calculation cannot be used to determine their capacity.

Solution

Selected result: 6MM Adjustable ARJO-6/150-200MM-5Dowel/3M

Input

Material

Concrete class C30/37

Soil k-value 0.05 N/mm3

Slab & Joint

Slab Thickness 170.00 mm

Length of the joint 3000.00 m

Total joint opening 20.00 mm

Leviat
President Way, President Park, Sheffield, S4 7UR, United Kingdom
info.isedio.uk@leviat.com
Leviat.com | Isedio.com
Project Name HDS Alternative Page 2/5
Customer Name Awan, Arslan Joint 1
Country United Kingdom 23-09-2024

Loads

Dead load gk 5.00 kN/m2 (γg = 1.35)

Live load qk 5.00 kN/m2 (γq = 1.5)

Point load type Single

Point load Qk 0.00 kN (γQ = 1.5)

Width of contact area WQ 200.00 mm

Distance btw. point loads XQ 500.00 mm

Forklift class #FL1 (γQ,dyn = 1.6, φ = 1.4)

Parallel to joint yes

Crossing the joint yes

Load cases

Vd(γg∙gk+γq∙qk+γQ∙Qk) 10.87 kN/m

Where

γg = partial load factor for permanent load

gk = permanent surface load

γq = partial load factor for live load

qk = live load

γQ = partial load factor for point load

Qk = point load

Vd(γg∙gk+γQ,dyn∙φ∙QFL,k) 16.52 kN/m

Where

γg = partial load factor for permanent load

gk = permanent surface load

γQ,dyn = partial load factor for dynamic load

QFL,k = forklift load

φ = dynamic magnification factor

Leviat
President Way, President Park, Sheffield, S4 7UR, United Kingdom
info.isedio.uk@leviat.com
Leviat.com | Isedio.com
Project Name HDS Alternative Page 3/5
Customer Name Awan, Arslan Joint 1
Country United Kingdom 23-09-2024

Calculation

Dowel Shear Capacity

Psh plate = A x 0.9 x 0.6 x pγ

Where

A = cross-sectional area of plate (mm2)

fyd = dowel steel design yield strength (N/mm2)

Where

A 900.00

Pγ 239.13

Psh plate 116.20 kN

Dowel Bearing/Bending Capacity

Pmax plate = 0.5[(b12+c1)0.5-b1]

Where

b1

c1 = 2k3fcdPb2tp2fyd

Where

b1 180000.00

c1 23243478260.87

Pmax plate 27.90 kN

Leviat
President Way, President Park, Sheffield, S4 7UR, United Kingdom
info.isedio.uk@leviat.com
Leviat.com | Isedio.com
Project Name HDS Alternative Page 4/5
Customer Name Awan, Arslan Joint 1
Country United Kingdom 23-09-2024

Punching shear capacity

vRd vmin x u1 x d

vmin = 0.035 x k1.5 x fck0.5

Where

fck = characteristic value of the concrete compressive

k = 1 + √(200/d) ≤ 2.0

Where

fck 30.00

k 2.00

vmin 0.54 kN

Where

d = effective depth taken as 0.75 times the distance

u1 = critical perimeter at 2.0d

Where

vmin 0.54

d 61.50

u1 646.42

Pshear cap 21.60 kN

Leviat
President Way, President Park, Sheffield, S4 7UR, United Kingdom
info.isedio.uk@leviat.com
Leviat.com | Isedio.com
Project Name HDS Alternative Page 5/5
Customer Name Awan, Arslan Joint 1
Country United Kingdom 23-09-2024

Calculation Summary

Spacing for single dowels 600.00 mm

Dowel Shear capacity 116.20 kN

Dowel Punching shear capacity 21.60 kN

Dowel Bearing / Bending capacity 27.90 kN

Governing capacity per linear meter 36.00 kN/m

Leviat
President Way, President Park, Sheffield, S4 7UR, United Kingdom
info.isedio.uk@leviat.com
Leviat.com | Isedio.com