Panel Builder
Panel Builder
Panel Builder
With effect from January 25th, 2022
se.com/in
Price List Contents
EasyPact CVS:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
EasyPact CVS Switch Disconnector Version. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Moulded Case Circuit Breakers:
ComPact NSX & NSXm:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
MCCB with Integrated Earth Leakage Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MCCB for Motor Protection:
GV4LE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
GV4PE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Accessories for GV4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Auxiliary Contact Blocks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ComPact NSX:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
MCCBs for Distribution Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Circuit Breakers for Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
MCCB with Integrated Earth Leakage Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Unique Modular Ground Fault Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
ComPact NS:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
EasyPact EZC:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Low MCCBs for Distribution Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Voltage Ground Fault / Earth Leakage Protection:
Vigirex - Earth Leakage Protection Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Products Switch Disonnector:
ComPact- INS & INV Switch Disconnectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Switch Disonnector fuse units - range overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
FuPact Switch Disconnector and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Air Circuit Breakers:
MasterPact MTZ:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Overview of MicroLogic X Trip Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
MasterPact NT/NW:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
MicroLogic Trip system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
ATS Kit range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
EasyPact MVS:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
ET/ETA/ETV Trip System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Draw-out type Circuit breakers and Switch Disconnectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Fixed type Circuit breakers and Switch Disconnectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
EasyPact SPS:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Draw-out type Circuit breakers and Switch disconnector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Fixed type Circuit breaker and Switch disconnector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
ASCO:
Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Series 7000/300, Automatic Transfer Switch (ASCO). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Series 230, Automatic Transfer Switch (ASCO). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
WOTPC, Automatic transfer switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Price List Contents
EasyPact TVS:
EasyPact TVS Power Contactors (3 Pole). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
EasyPact TVS Power Contactors (4 Pole). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
EasyPact TVS Contactor Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
EasyPact TVS Thermal Overload Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
EasyPact TVS Circuit Breaker for Motor Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
TeSys Control:
TeSys K Control Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
TeSys K Power Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
TeSys K Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
TeSys Deca Control Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEW
90
TeSys Deca Power Contactors (3 Pole). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEW
90
TeSys Deca Power Contactors (4 Pole). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEW 91
TeSys Deca Green. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEW 92
TeSys Deca Green Electric Coil Contactor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEW 93
TeSys Deca Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEW 94
TeSys Giga Power Contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEW 101
TeSys F Power Contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Switching TeSys F - Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TeSys Special Purpose Contactor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
and TeSys H Ultra compact. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
TeSys Protect:
Controlling TeSys Overload Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
TeSys Electronic Over Current Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Products TeSys Power:
TeSys Motor Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
GV4LE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
GV4PE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Accessories for GV4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Auxilary Contact Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Circuit Breakers for Motor Protection Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
TeSys Switches:
TeSys Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
TeSys Active:
TeSys island. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
TeSys U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
TeSys T - iMCC Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
TeSys Starters:
Enclosed Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Selection Table:
Type 2 Co-ordination Charts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 to 137
Type 2 Co-ordination chart with TeSys Giga range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEW 138 to 142
Type 2 Recommended Selection Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 to 149
Phaseo:
Phaseo Power Supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Phaseo Transformers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Altivar:
Altivar Variable Frequency Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Altistart
Industrial Altistart Soft Starters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Zelio Logic:
Automation Zelio Plug-in-Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Zelio SSR / Electronic Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Products Harmony:
Harmony Control & Signalling Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
Signalling:
Signalling Control Stations & Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Signalling Illuminated Beacons and Indicator Banks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Signalling Monolethic Tower Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Price List Contents
Osisense
Osisense Photoelectric Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Osisense Pressure Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Osisense Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Osisense Inductive Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Industrial Osisense Application Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Osisense Cable Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Automation Magelis:
Magelis Industrial PC and Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
Products Magelis RACK IPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Magelis Basic HMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Vijeo:
Vijeo XD EcoStruxure™ Operator Terminal Expert. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Vijeo Designer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Flexible Payments
Express Delivery
Explore more at
shop.schneider-electric.co.in
Green Premium
TM
se.com/in 8
Protect uptime and business countinuity
From Preventive to Predictive Maintenance
Main Busbar
joint
Function unit
Schneider Electric LV switchboard Thermal Monitoring minimizes downtime and increases safety while reducing
insurance premiums related to fire risks
Given such risks, keeping critical equipment up and running is a priority in buildings and facilities worldwide. The
objectives are three-fold:
• Maintain operational uptime and business continuity
• Reduce operational expenses and total cost of ownership
• Protect building occupants and electrical distribution equipment
The Thermal Monitoring design combines a robust and proven architecture, standardized modules, and Schneider
Electric devices. Permanently installed sensors on busbar connections, cable compartments, and breaker contacts
provide continuous monitoring to perform predictive maintenance.
While IR inspections may miss critical conditions that happen between scheduled scans, Thermal Monitoring not
only detects potential hazards but immediately sends alerts to operations and maintenance teams, allowing them to
respond before any unsafe or damaging conditions occur.
(1) European Fire Academy
connection
24/7 local
condition monitoring
ENABLED ENABLED+
se.com/in 9
Improve safety with early detection
of cable overheating
Electrical fires can generate huge losses in commercial buildings from the loss of business continuity, business
opportunity costs, assets, and production loss. These losses can be so significant that they can even destroy companies.
Mechanism Frequency
Poor connections Most
Arcing across a carbonized path
Arcing in air
Excessive thermal insulation
Overload
Ejection of hot particles
Dielectric breakdown in solid or liquid insulators
Miscellaneous phenomena Least
Typical connection issues in LV electrical assemblies
A thermographic image of a cable
connection on a MCCB showing how a
The equipment inside LV switchgear and panelboards is susceptible to a range
loose connection causes the connection
of fire risks, as defined by the IEC 63054 standard. Of these risks, poor point and cable to overheat.
connections are the most frequent.
Detection of abnormal heating Loose cable connections can contribute to thermal runaway.
PowerLogic HeatTag sensors identify potential problems before they get out of control.
HeatTag is a Smart Sensor for Early Detection of Overheating wire connections or cables.
HeatTag helps preventing electrical cabinets from being damaged, by analyzing gas and
particles in the air and sending alerts before any smoke or insulator browning
HeatTag™ smart
insulation decomposition
detection (IDD) device
IDD device
PowerLogic™ HeatTag
Switchboard condition analysis:
• Analyzes gases and micro-particles
emitted by overheating cable
• 3 level of alerts depending on severity
• Measures ambiant temperature and
hygrometry
• Provides switchboard air quality index
se.com/in 10
EcoStruxure™ Facility Expert
Designed to keep you in touch with your equipment
se.com/in 11
Product Selector
-Select Schneider products through digital tool
Product selector is an online software tool embedded in Schneider website or in distributor´s website to help selecting the right product
with its accessories. Product Selector aims at providing a fast, secure and smart way of selecting products. It includes the selection of
the basic frame, control unit, accessories and Digital Modules. Compared with the traditional way of filling up order forms or specifying
customer functions, it brings the following benefits:
Easy access: no login, direct access on Schneider's website or on the website of distributor
Reliable: The compatibility between the main product and the accessories is constantly tested
Wide coverage: more than 130 Schneider ranges are available (MasterPact)
se.com/in 12
Future of Power Distribution
Stay connected and avoid downtime - The MasterPact MTZ Contribute to a better world - with Green Premium MasterPact
app and EcoStruxure software conveniently bring energy MTZ circuit breakers you can enhance sustabinability.
data, circuit breaker control, and more directly to your
smartphone.
Access new energy-saving capabilities - Acertified Class Keep your electrical system online even in harsh
1 power meter gives you precise power measurements for environments - MasterPact MTZ circuit breakers give you
greater efficiency. proven reliability by going beyond standards.
Customize Micrologic X control unit anytime - Digital Simplify your switchboard operation - MasterPact MTZ circuit
modules make it easy to upgrade and tailor your system. breakers are adaptable to different systems because of their
digital capabilities.
se.com/in 13
EasyPact ™
CVS
Molded-case circuit breakers and
switch-disconnectors from 16 to 630A
se.com/in
se.com/in 14
EasyPact CVS
Easy Choice for Quality and Value
• EasyPact CVS MCCBs upto 630A is the easy choice for all your most common electrical distribution applications
• Encapsulated double break roto technique ensures outstanding current limiting capability
• High electrical / mechanical endurance for enhanced service life
• Single accessory reference for different functions – on/off, trip and fault trip – improves shop floor efficiency
• Separate electrical fault indication for ease of fault diagnosis
• Class 2 front face, Locking in off position, Suitable for Isolation
• Only two frame sizes
Range Details:
• Breaking capacity 25kA to 50kA, Ics = 100% Icu
• TMD, MA, Microprocessor trip units (LS0I protection 400 & 630A)
• Microprocessor trip units (LSIG protection 25A to 630A)
• 3P & 4P versions available
• Common accessories upto 630A
se.com/in 15
EasyPact CVS 100 BS Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 100 BS Overload Setting (Ir) 0.8 - 1 x In
20A LV510931 LV510951
12120
25A LV510932 LV510952
32A LV510933 LV510953 10390
40A LV510934 LV510954
25kA* 7680 12120
50A LV510935 LV510955
63A LV510936 LV510956
80A LV510937 LV510957 10390
100A LV510938 LV510958
Accessories
CVS100BS Unit MRP
Description
Reference [`]
Auxiliary contacts (changeover) Multifunction
Auxiliary Switch 1 C/O EZAUX10
1110
Alarm Switch 1 C/O EZAUX01
Alarm - Auxiliary Switch EZAUX11 1645
Spreaders
Spreaders *(Set Of 3) 3P EZASPDR3P 440
Spreaders *(Set Of 4) 4P EZASPDR4P 590
Rotary Handle
Direct Rotary handle EZAROTDS 1565
Extended Rotary handle EZAROTE 2310
Shunt Release
AC
100-130 V EZASHT100AC
2370
200-277 V EZASHT200AC
380-480 V EZASHT380AC 2700
DC
24 V EZASHT024DC
2370
48 V EZASHT048DC
* Ics = 17kA
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 16
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 100 to 630A Overload Setting (Ir) 0.7 - 1 x In
16A LV510300 LV510310
25A LV510301 LV510311
32A LV510302 LV510312
40A LV510303 LV510313
8180 11320
50A LV510304 LV510314
25kA 63A LV510305 LV510315
80A LV510306 LV510316
100A LV510307 LV510317
125A LV516302 12040 LV516312 14600
160A LV516303 15710 LV516313 18650
200A LV525302 20810 LV525312 25760
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
25kA 250A LV525303 24230 LV525313 29500
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 100 to 630A Overload Setting (Ir) 0.7 - 1 x In
16A LV510330 LV510340
25A LV510331 LV510341
32A LV510332 LV510342
40A LV510333 LV510343
11140 13910
50A LV510334 LV510344
36kA 63A LV510335 LV510345
80A LV510336 LV510346
100A LV510337 LV510347
125A LV516332 12380 LV516342 15290
160A LV516333 16390 LV516343 19420
200A LV525332 23600 LV525342 29110
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
250A LV525333 26180 LV525343 32250
320A LV540305 33730 LV540308 41850
36kA 400A LV540306 33920 LV540309 42210
500A LV563305 38640 LV563308 48700
630A** LV563306 43780 LV563309 53450
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
16A LV510470 LV510480
25A LV510471 LV510481
32A LV510472 LV510482
40A LV510473 LV510483
15120 18590
50A LV510474 LV510484
50kA 63A LV510475 LV510485
80A LV510476 LV510486
100A LV510477 LV510487
125A LV516462 19660 LV516467 21520
160A LV516463 21280 LV516468 25330
200A LV525452 27540 LV525457 34600
Breaking Capacity Rated Current Three Pole Unit MRP Four Pole Unit MRP
as per IEC 60947-2 Reference [`] Reference [`]
250A LV525453 29600 LV525458 36480
320A LV540315 36710 LV540318 45170
50kA 400A LV540316 36990 LV540319 46000
500A LV563315 42880 LV563318 53850
630A** LV563316 45740 LV563319 57310
Note:
* *630A @ 300C & 600A @ 400 C for TMD630A MCCB
For details
Details on
on non standard
stockable andreferences, technical
non-stockable status,parameters, accessories,
technical parameter, compatibility,
please stockableCare
Contact Customer and Centre
non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 17
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Ics Three Pole Unit MRP Four Pole Unit MRP
Rated Current
as per IEC 60947-2 Reference [`] Reference [`]
EasyPact CVS 400 to 630A
400A LV540505 40980 LV540506 51060
36 kA
630A LV563505 45040 LV563506 59770
400A LV540510 44980 LV540511 58230
50 kA
630A LV563510 48970 LV563511 64050
Magnetic
Current Rating 2.5 6.3 12.5 25 50 100 150 220 320 500
setting
CVS 100 6....14 x In
CVS 160/250 9....14 x In
Im = In x ...
CVS 400 6....13 x In
CVS 630 6....13 x In
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 18
EasyPact CVS Moulded Case Circuit Breakers for
Distribution Network
se.com/in 19
EasyPact CVS Accessories for EasyPact CVS
Indication contacts Voltage Release Padlocking accessory Direct Rotary Handle Extended Rotary Handle
Voltage Releases
Shunt Release Unit MRP Undervoltage Unit MRP
Description
Reference [`] Reference [`]
AC
24 V 50/60 Hz LV429384 LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386 LV429406 3695
3020
220-240 V 50/60 Hz LV429387 LV429407
380-415 V 50 Hz LV429388 LV429408
525 V 50 Hz LV429389 LV429409 4320
DC
12 V LV429382 LV429402
3695
24 V LV429390 LV429410
3020
30 V LV429391 LV429411 4320
48 V LV429392 LV429412 3695
60 V LV429383 3450 LV429403 4320
125 V LV429393 LV429413
3020 3695
250 V LV429394 LV429414
Rotary Handles
100/160/250A Unit MRP 400/630A Unit MRP
Description
Reference [`] Reference [`]
Direct rotary handle
Standard black handle LV429337 1470 LV432597 2205
Extended rotary handle
Standard extended rotary handle LV429338_IN 2030 LV432598_IN 3600
Installation Accessories
100/160/250A Unit MRP 400/630A Unit MRP
Description
Reference [`] Reference [`]
Spreaders & Phase Barriers
Spreaders (Set of 3) 3P LV431563 710 32492 1590
Spreaders (Set of 4) 4P LV431564 940 32493 2030
Phase Barriers (Set of 6) * LV432570 950
Interlocking
For Breaker with Rotary Handle LV429369 10905 LV432621
13730
For Breaker with Toggle LV429354 13060 LV432614
Mechanical Interlocking with Base Plate 29349** - 32609** -
Locking of Rotary Handle
Locking Device LV429344 700 LV432604 950
Ronis Keylock (1 Lock + 1 Key set) 41940 4770 41940 4770
Ronis Keylock (2 Locks + 1 Key set) 41950 8835 41950 8835
Profalux Keylock (1 Lock + 1 Key set) 42888 8050 42888 8050
Profalux Keylock (2 Locks + 1 Key set) 42878 9185 42878 9185
* supplied as standard with spreaders
** Mechanical Interlocking with Base Plate to be ordered with Safety trip interlock (LV429270 for 29349 and LV432520 for 32609)
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 20
EasyPact CVS Accessories for EasyPact CVS
Unit MRP
Description Reference
[`]
Mechanical interlocking for circuit breakers
With toggles 100A to 250A LV429354 13060
With rotary handles 100A -250A LV429369 10905
With toggles 400A to 630A LV432614
13730
With rotary handles 400A to 630A LV432621
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 21
ComPacT
NSX & NSXm
Molded-Case Circuit Breakers
And Switch-Disconnectors
From 16 To 630 A - Up To 690 V
se.com/in
se.com/in 22
ComPact NSXm & NSX
New New
ComPact Design Wireless Auxiliary Contact
se.com/in 23
ComPact NSXm & NSX
For example, ComPacT NSX & NSXm contribute to 3 LEED™ points in the
Building Product Disclosure and Optimization section:
Green
Premium
TM
ComPacT NSX range is now enriched with the new ComPacT NSXm,
designed according to the EcoDesign Way™ by Schneider. It now
features new space saving frame size for reduced resource
consumption, and more.
New Packaging
• The ComPacT range comes in plastic-less packaging: not only
to reduce our carbon footprint, but it also means less waste in
the workshop
• Simplified instruction sheets included in all packaging
• 100% recycled carton
• Scan QR codes for access to digital documentation
• This product is REACH and RoHS compliant
se.com/in 24
ComPact NSXm & NSX
Application Overview
The ComPacT NSX and NSXm circuit breakers and swith-disconnectors are the best choice for all standards
and specific applications.
> ComPacT INS/INV [a] > FuPacT [a] > Substitution and Technical Guide
ComPacT NSX High Performances [b]
> ComPacT NSX, ComPacT INS/INV, > Transfer PacT > Complementary technical information
MasterPact NW DC - DC PV - DC EP [c] (Source-changeover systems) [d]
se.com/in 25
ComPact NSXm & NSX
We understand any change in commercial references will be an adjustement, but in the long run we believe
this change is needed, and will make your life easier.
...
Each breaker is equipped with a QR code that allows you to get the
latest information on your breaker.
se.com/in 26
ComPact NSXm Moulded Case Circuit Breakers
se.com/in 27
ComPact NSXm MCCB with Integrated
Earth Leakage Protection
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 28
ComPact NSXm Switch Disconnector
pact
Com
6559 act
LV42 Comp
et
4P frame
559
Res
40°C
LV426
OFF
Cat.A
-2
IEC/EN60947
8kV
Uimp 40°C
50/60Hz Ics(kA) Cat.A
Ui 8kV Icu(kA) 100 IEC/EN60947-2 Uimp
8kV
Ue(V)
100 70 50/60Hz Ics(kA)
240 70 65 Ui 8kV Icu(kA) 100
65 100 70
415 30 Ue(V)
70
240 65
440 30 22 65
415 30
500 22 6 440 30 22
525 10 500 22 6
525 10
690
690
2
GB14048. GB14048.2
AB1 AB1 HIC
NEMA HIC NEMA 100
100 65
65 240 25
240 25 480
600Y/347
480
Trip
600Y/347
Ø 4.
On
..8
Trip
MN Off
Ø 4...8
250V
4P frame
Reset
~/=
t
se
Re
pact
Com
6559
LV42
40°C
Cat.A
47-2 8kV
50/60Hz Uimp
IEC/EN609 Ics(kA)
100
Ui 8kV Icu(kA) 100 70
Ue(V) 240 70 65
415 65 30
440 30 22 On
500 22 6
525 10
Ø 4...8
690
Trip
8.2 AB1 HIC
GB1404 NEMA
100
65
Ø 4.
25
240
480
600Y/347
..8
Trip
Off
Ø 4...8
Reset
Terminal spreaders OF or SD auxiliary MN or MX voltage Direct rotary handle Side Rotary handle Extended rotary handle
contact standard releases standard
NSXm Accessories
Auxiliary contacts (changeover) Voltage Releases
Unit MRP Shunt Release Unit MRP Under Voltage Unit MRP
Description Reference Description
[`] Reference [`] Reference [`]
Standard OF or SD LV426950 1080 AC
Rotary Handles 24 V 50/60 Hz LV426841 2565 LV426801 3630
48 V 50/60 Hz LV426842 3100 LV426802
Unit MRP
Description Reference 110-130 V 50/60 Hz LV426843 2565 LV426803
[`] 3335
220-240 V 50/60 Hz LV426844 2690 LV426804
Direct rotary handle
380-415 V 50 Hz LV426846 2565 LV426806
LV426930/
Standard black handle 1385 DC
LV426930T
Extended rotary handle 24 V LV426841 2565 LV426801 3630
Standard extended rotary LV426932/ 48 V LV426842 3100 LV426802
2200 3335
black handle LV426932T 125 V LV426843 2565 LV426803
Side rotary handle 250 V LV426844 2690 LV426815 4030
Standard side rotary black LV426935/
3520
handle LV426935T
Spreader Links
Unit MRP
Description Reference
[`]
Spreaders & Phase Barriers
Spreaders (Set of 3) 3P LV426940 810
Spreaders (Set of 4) 4P LV426941 1100
Everlink Accessories
Unit MRP
Description Reference
[`]
Everlink Connectors
EverLink connector with control
LV426970 990
wire terminal for 3P (Set of 3)
EverLink connector with control
LV426971 1290
wire terminal for 4P(Set of 4)
se.com/in 29
TeSys Power Circuit Breakers for Motor Protection
GV4LE
• IEC/EN 60947-1, IEC/EN 60947-2, CCC, EAC
• Can be used with class 5, 10 or 20 relay
• Short Circuit Protection with an adjustable pick-up Ii = 6 to 14 In.
• From 0.25 - 55kW
Note: For Everlink termination please order after removing the 6 at the end Eg. GV4LE115N
GV4PE
• IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60497-4-1,
CCC, EAC, CSA
• Overload or thermal protection
• Short time delay protection
• Short circuit protection
• Fixed Ground fault protection
• Phase unbalance or phase loss
• Front indications through LED
• Variable Trip class : Trip Class 10/ Trip Class 20
Note: For Everlink version please order after removing the 6 at the end. Eg. GV4PE115N
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation,
accessories, andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 30
TeSys Power Circuit Breakers for Motor Protection
Unit MRP
Description Mounting Voltage References
[`]
220-240 VAC 50 Hz, 208-240 VAC 60 Hz,
Mx Shunt Trip Internal, Plug-In GV4AS287 3465
277 VAC 60 Hz
Mn Under Voltage Release Internal, Plug-In 440-480 VAC 60 Hz GV4AU486 5125
Unit MRP
Description Maximum Number Mounting Type of Contacts Reference
[`]
Auxiliary Contact Block 2 (1 Each For OF or SD) Internal Plug-In NO + NC GV4AE11 1220
Rotary Handles
Unit MRP
Description Type Degree of Protection Reference
[`]
Direct Mounting Rotary Handle BLACK IP40 GV4ADN01 1815
BLACK IP54 GV4APN01
RED HANDLE ON 2695
Front Extended Rotary Handle (Min Shaft Length 214Mm/Max IP54 GV4APN02
YELLOW BEZEL
Shaft Length 627Mm)
RED HANDLE ON
IP65 GV4APN04 2835
YELLOW BEZEL
Connection Accessories
Description Reference
Spreader 3-pole (To increase pitch to 35mm) (1 pce) LV426940
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation,
accessories, andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 31
Moulded Case Circuit Breaker
se.com/compact-nsx
se.com/in 32
ComPact NSX
• Ethernet based communication system for monitoring, control, alarm notification for
energy, asset and network management
• Built-in energy metering with combined accuracy class of 2% for precise
measurement
• Wireless auxiliary Contacts accelerates overall wiring time: status communication is
done very simply and commissioned wirelessly
• Intelligent discrimination for continuity of service and enhanced discrimination by
cascading
• Patented reflex tripping, independent of other protection functions, ensures ultra fast
tripping in the event of very high short circuit
• Encapsulated roto-active double break contact system limits fault current for extended
system life
• Best in class electrical life (30k cycles for NSX 100 @ 440 V) reduces operational expenditure
• High performance => Ics = Icu = 100kA @ 690V AC
Range Details:
• 16A to 630A in two frames sizes
• Breaking capacity up to 200kA @ 415V
• TMD and Electronic based trip unit
• Available in Fixed, Plug-in and Draw out type versions
se.com/in 33
ComPact NSX Moulded Case Circuit Breakers for
Distribution Network
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 34
ComPact NSX Moulded Case Circuit Breakers for
Distribution Network
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 35
ComPact NSX Moulded Case Circuit Breakers for
Distribution Network
NSX Micrologic 6E
Protection
• Ics = 100% Icu as per IEC 60947-2
• Breaking Capacity enhancement upto 150kA with a higher capacity
upstream (Cascading)
• External Neutral CT required for highly un-balanced TP-N system
(* has to be ordered at extra price)
• Adjustable neutral protection - N, N/2,OFF and oversized neutral
(standard feature) for 4 Pole MCCB.
• Adjustable overload from Ir 0.4 to 1 x In and tr = 0.5 to 16 s
• Adjustable short circuit from Isd 1.5 to 10 x Ir and tsd I2t ON/OFF 0.1 to 0.4s
• Adjustable earth fault 0.4 to 1 x In (for In=40A) & 0.2 to 1 x In (for In>40A)
and tg I2t ON/OFF 0.1 to 0.4s
• Instantaneous protection Ii 1.5 x In to 15 x In (40 - 160A), 12 x In (250 to
400A)and 11 x In (630A)
• Zone Selective Interlocking (ZSI) as standard
Breaking Capacity Icu Three Pole Unit MRP Four Pole Unit MRP
Rated Current
as per IEC 60947-2 Reference [`] Reference [`]
100A C10F36E100 C10F46E100
160A C16F36E160 C16F46E160
36kA 250A C25F36E250 C25F46E250
400A C40F36E400 C40F46E400
630A C63F36E630 C63F46E630
100A C10N36E100 C10N46E100
160A C16N36E160 C16N46E160
50kA 250A C25N36E250 On Request C25N46E250 On Request
400A C40N36E400 C40N46E400
630A C63N36E630 C63N46E630
100A C10H36E100 C10H46E100
160A C16H36E160 C16H46E160
70kA 250A C25H36E250 C25H46E250
400A C40H36E400 C40H46E400
630A C63H36E630 C63H46E630
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 36
ComPact NSX Circuit Breakers for Motor Protection
Breaking Capacity Icu Three Pole Unit MRP Four Pole Unit MRP
Rated Current
as per IEC 60947-2 Reference [`] Reference [`]
400A C40F3TM400D 46940 C40F4TM400D 53290
36kA 500A C63F3TM500D 56300 C63F4TM500D 68820
600A C63F3TM600D 59460 C63F4TM600D 71980
400A C40S3TM400D 67020 C40S4TM400D 81630
100kA 500A C63S3TM500D 73180 C63S4TM500D 88270
600A C63S3TM600D 73180 C63S4TM600D 88270
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 37
ComPact NSX MCCB with Integrated Earth
Leakage Protection
Breaking Capacity Icu Three Pole Unit MRP Four Pole Unit MRP
Rated Current
as per IEC 60947-2 Reference [`] Reference [`]
40A C10B34V040 39240 C10B44V040 44010
100A C10B34V100 39240 C10B44V100 44010
25kA
160A C16B34V160 41550 C16B44V160 50060
250A C25B34V250 47610 C25B44V250 56990
40A C10F34V040 39240 C10F44V040 45160
100A C10F34V100 39240 C10F44V100 45160
160A C16F34V160 42850 C16F44V160 50930
36kA
250A C25F34V250 48040 C25F44V250 58850
400A C40F34V400 66640 C40F44V400 75010
570A C63F34V570 76450 C63F44V570 89140
40A C10N34V040 42850 C10N44V040 48620
100A C10N34V100 42850 C10N44V100 48620
160A C16N34V160 48620 C16N44V160 51930
50kA
250A C25N34V250 51790 C25N44V250 60300
400A C40N34V400 68380 C40N44V400 82790
570A C63N34V570 76740 C63N44V570 94910
40A C10H34V040 47310 C10H44V040 54390
100A C10H34V100 47310 C10H44V100 54390
160A C16H34V160 58140 C16H44V160 64620
70kA
250A C25H34V250 59290 C25H44V250 90150
400A C40H34V400 87700 C40H44V400 109480
570A C63H34V570 90290 C63H44V570 120000
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 38
ComPact NSX Accessories
Indication contacts SDTAM remote SDx remote Voltage Release Motor Mechanism
indication relay indication relay
module module
Unit MRP
Description Reference
[`]
Auxiliary contacts (changeover) Multifunction
OF or SD or SDE or SDV 29450 1050
OF or SD or SDE or SDV low level 29452 1220
SDE adaptor for trip unit TM or MA or Micrologic 2 $$ LV429451 895
SDX 2-PROGRAMMABLE CONTACTS FOR MICROLOGIC
SDx module 24/415 V AC/DC LV429532 15315
SDTAM contactor tripping module for Micrologic 2- M/6 E-M
SDTAM 24/415 V AC/DC overload fault indication LV429424 15880
Voltage Releases
Shunt Release Unit MRP Undervoltage Unit MRP
Description
Reference [`] Reference [`]
AC
24 V 50/60 Hz LV429384 LV429404
48 V 50/60 Hz LV429385 LV429405
110-130 V 50/60 Hz LV429386 LV429406 3695
3020
220-240 V 50/60 Hz LV429387 LV429407
380-415 V 50 Hz LV429388 LV429408
525 V 50 Hz LV429389 LV429409 4320
DC
12 V LV429382 LV429402
3695
24 V LV429390 LV429410
3020
30 V LV429391 LV429411 4320
48 V LV429392 LV429412 3695
60 V LV429383 3450 LV429403 4320
125 V LV429393 LV429413
3020 3695
250 V LV429394 LV429414
Installation Accessories
100/160/250A Unit MRP 400/630A Unit MRP
Description
Reference [`] Reference [`]
Spreaders & Phase Barrier
Spreaders (Set of 3) 3P LV431563 710 32492 1590
Spreaders (Set of 4) 4P LV431564 940 32493 2030
Phase Barrier (Set of 6) * - LV432570 950
Interlocking
For Breaker with Rotary Handle LV429369 10905 LV432621
13730
For Breaker with Toggle LV429354 13060 LV432614
Mechanical Interlocking with Base Plate 29349** - 32609** -
Locking of Rotary Handle
Locking Device LV429344 700 LV432604 950
Ronis Keylock (1 Lock + 1 Key set) 41940 4770 41940 4770
Ronis Keylock (2 Locks + 1 Key set) 41950 8835 41950 8835
Profalux Keylock (1 Lock + 1 Key set) 42888 8050 42888 8050
Profalux Keylock (2 Locks + 1 Key set) 42878 9185 42878 9185
* supplied as standard with spreader
** Mechanical Interlocking with Base Plate to be ordered with Safety trip interlock (LV429270 for 29349 and LV432520 for 32609)
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 39
ComPact NSX Accessories
FDM121: Front Display Test Battery Power Supply ModuleB SCM: Breaker Status and
Module Control Module
Motor Mechanism
100/160A Unit MRP 250A Unit MRP 400/630A Unit MRP
Type Voltage
Reference [`] Reference [`] Reference [`]
Motor Mechanism Modules with SDE Adaptor (1)
48-60 V LV429440 LV431548 LV432639
110-130 V LV429433 LV431540 LV432640
AC
220-240 V LV429434 28440 LV431541 31430 LV432641 45680
50/60 Hz
380-415 V LV429435 LV431542 LV432642
440-480 V LV429435 LV431542 LV432647
24-30 V LV429436 LV431543 LV432643
48-60 V LV429437 LV431544 LV432644
DC 38765 42035 55550
110-130 V LV429438 LV431545 LV432645
250 V LV429439 LV431546 LV432646
(1) With every Motor Mechanism, please order 1 no. auxiliary contact additionally. For other voltages of motor mechanism please consult Customer Care.
Unit MRP
Description Reference
[`]
ULP Display Module
Switchboard front display module FDM121 TRV00121 16030
ULP Wiring Accessories
NSX cord L = 0.35 m LV434200 3705
NSX cord L = 1.3 m LV434201 3800
5 RJ45/RJ45 MALE Cord L = 1m TRV00810 3505
10 Stacking connectors for COM interface TRV00217 5460
ULP Communication Module
IFM MODBUS Interface Module LV434000 12740
BSCM ( Breaker Status and Control Module) LV434205 11940
Power Supply Modules
External power supply module 24 V DC-1 A OVC IV
200-240 V AC LV454444 19060
Pocket battery for Micrologic NSX100-630 LV434206 23315
Maintenance Module for advanced configuration and testing, contact our nearest Sales office.
ULP = Universal Logic Plug
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 40
ComPact NSX Accessories
Direct Rotary Handle Extended Rotary Handle Plug in Base Draw-Out Chassis Kit
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 41
Unique Modular Ground Fault Protection
Note: Kindly order one no. Shunt trip coil along with one Ground Fault Protection Module for CVS100 to 630.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 42
ComPact NS
Molded case circuit breakers and switch-disconnectors
from 630b to 3200 A
Compact is an integral part of EcoStruxure™ Power – Schneider’s open, interoperable, IoT-enabled system
architecture. Through this platform, we deliver enhanced value around safety, reliability, efficiency, sustainability,
and connectivity for our customers. We leverage technologies in IoT, mobility, sensing, cloud, analytics, and
cybersecurity to deliver Innovation at Every Level. This includes Connected Products, Edge Control, and Apps,
Analytics & Services. EcoStruxure has been deployed in 450,000+ installations, with the support of 9,000 system
integrators, connecting over 1 billion devices.
Offering proven performance, flexibility and reliability, the Compact NS sets the standard in most applications:
buildings, windturbine, solar, genset, data center, healthcare, marine and infrastructure and decrease your energy
consumption thanks to very low power dissipation.
Equipped with the Micrologic control units, Compact NS630b to 3200 A circuit breakers offer built-in power and
energy metering in addition to electrical measurement and analysis functions.
The communication option makes it possible to control power consumption, simplify maintenance and improve
operating comfort.
A wide range of optimized auxiliaries and accessories is available to meet the needs of protection of AC
installations, generator protection, motor protection, switch-disconnectors, source changeover switch function and
specific offers available for DC applications up to 1000 V.
se.com/in 43
ComPact NS
Standards
Compact NS circuit breakers and auxiliaries comply with:
• IEC/EN 60947-1: General rules
• IEC/EN 60947-2: Circuit-breakers
• IEC/EN 60947-3: Switch-disconnectors
• IEC/EN 60947-4-1: Contactors and motor-starters
• IEC/EN 60947-5-1: Control circuit devices
se.com/in 44
ComPact NS
Micrologic E
Micrologic P
For Product reference number and prices, please contact nearest sales office
se.com/in 45
EasyPact EZC
With just three sizes of circuit breakers, Schneider Electric’s EasyPact EZC system is the simple, universal solution, particularly
Range Details:
• Global MCCB offer from 15A to 600A
• Breaking capacity upto 50kA @ 415 V AC
• 1P, 2P, 3P and 4P versions available
• EZC AC version is suitable for DC applications upto 250V DC (15A to 250A breaking capacity up to 30kA)
Breaking capacity
DB402889_1
Icu kA at 400/415V AC
50
EZC400H EZC630H
36
EZC250H EZCV250H EZC400N EZC630N
30
EZC100H
25
EZC250N EZCV250N
18
15 EZC250F
EZC100N
10
EZC100F
7.5
EZC100B
se.com/in 46
EasyPact EZC Moulded Case Circuit Breakers for
Distribution Network
Unit MRP
BREAKING CAPACITY ICU AS PER IEC 60947-2 Rated Current Three Pole Reference
[`]
16A EZC100F3016
20A EZC100F3020
25A EZC100F3025
32A EZC100F3032
“10 kA @ 415V AC
40A EZC100F3040 3490
5kA @ 250V DC (2pole in series)”
50A EZC100F3050
63A EZC100F3063
80A EZC100F3080
100A EZC100F3100
125A EZC250F3125 8955
150A EZC250F3150 9015
“18 kA @ 415V AC
160A EZC250F3160 10220
5kA @ 250V DC (2pole in series)”
175A EZC250F3175
12555
200A EZC250F3200
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
“18 kA @ 415V AC
250A EZC250F3250 14680
5kA @ 250V DC (2pole in series)”
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Single Pole
[`]
16A EZC100N1016 3220
20A EZC100N1020 2825
25A EZC100N1025
3220
32A EZC100N1032
"18 kA @ 240V AC
40A EZC100N1040
5kA @ 125V DC " 2825
50A EZC100N1050
63A EZC100N1063
3220
80A EZC100N1080
100A EZC100N1100 2825
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Two Pole Reference
[`]
16A EZC100H2016
20A EZC100H2020
25A EZC100H2025
32A EZC100H2032
“50 kA @ 240V AC
40A EZC100H2040 4595
10kA @ 250V DC (2pole in series)”
50A EZC100H2050
63A EZC100H2063
80A EZC100H2080
100A EZC100H2100
125A EZC250H2125 9470
150A EZC250H2150 11155
“85 kA @ 240V AC
160A EZC250H2160 12740
30kA @ 250V DC (2pole in series)”
175A EZC250H2175
13430
200A EZC250H2200
Unit MRP
Breaking Capacity Icu as per IEC 60947-2 Rated Current Three Pole Reference
[`]
“85 kA @ 240V AC
250A EZC250H2250 13820
30kA @ 250V DC (2pole in series)”
Note:
• Contact customer care for 1P(up to 100A) and 2P (up to 250A) requirements.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 47
EasyPact EZC Moulded Case Circuit Breakers for
Distribution Network
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
15A EZC100H3015 EZC100H4015
20A EZC100H3020 EZC100H4020
25A EZC100H3025 EZC100H4025
32A EZC100H3032 EZC100H4032
“30 kA @ 415V AC
40A EZC100H3040 6300 EZC100H4040 8730
10kA @ 250V DC (2pole in series)”
50A EZC100H3050 EZC100H4050
63A EZC100H3063 EZC100H4063
80A EZC100H3080 EZC100H4080
100A EZC100H3100 EZC100H4100
125A EZC250N3125 9175 EZC250N4125 12655
“25 kA @ 415V AC
160A EZC250N3160 11120 EZC250N4160 14885
20kA @ 250V DC (2pole in series)”
200A EZC250N3200 13195 EZC250N4200 16645
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
"25 kA @ 415V AC
250A EZC250N3250 15080 EZC250N4250 19505
20kA @ 250V DC (2pole in series)"
Breaking Capacity Icu as per Rated Current Three Pole Reference Unit MRP Four Pole Unit MRP
IEC 60947-2 [`] Reference [`]
125A EZC250H3125 9370 EZC250H4125 12630
"36 kA @ 415V AC
160A EZC250H3160 12270 EZC250H4160 15440
30kA @ 250V DC (2pole in series)"
200A EZC250H3200 15240 EZC250H4200 20590
Breaking Capacity Icu as per Rated Current Three Pole Unit MRP Four Pole Unit MRP
IEC 60947-2 Reference [`] Reference [`]
“36 kA @ 415V AC
250A EZC250H3250 17040 EZC250H4250 23010
30kA @ 250V DC (2pole in series)”
320A EZC400H3320N 25730 EZC400H4320N 29680
400A EZC400H3400N 26550 EZC400H4400N 35540
“50 kA @ 415V AC“
500A EZC630H3500N 35150 EZC630H4500N 45685
600A EZC630H3600N 36630 EZC630H4600N 47750
Note:
• Contact customer care for 1P(up to 100A) and 2P (up to 250A) requirements
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 48
EasyPact EZC Accessories
Unit MRP
Description EZC 400/600 Reference
[`]
Auxiliary Contacts
OF or SD or SDE 29450 1050
Spreaders
Spreaders (Set of 3) 3P 32492 1590
Spreaders (Set of 4) 4P 32493 2030
Phase Barriers (Set of 6) LV432570 950
Rotary Handle
Direct Rotary handle LV432597 2205
Extended Rotary handle LV432598 3600
Shunt Release
AC 220-240 V 50/60 Hz LV429387 2100
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 49
Vigirex Earth Leakage Protection Relay
Vigirex Relays
Vigirex Relays along with Vigirex Sensors, may be may be used to add external Earth Leakage Protection to Circuit Breakers
• Sensitivity Adjustments from 30mA to 30A and time delay settings from (0-4.5 seconds)
• Closed Toroid up to 630A (30 to 300mm in diameter), Split Toroid up to 250A (46 to 110mm in diameter) or
• Rectangular sensor up to 3200A
• 400Hz Distribution System
Note: For further details, please contact our nearest Sales Office.
Din rail mount Unit MRP Front panel mount Unit MRP
Type Control Voltage
Reference [`] Reference [`]
RH10 with local manual fault reset 220/240VAC 56130 56230 16555
15075
Sensitivity=0.03A 380/415VAC 56140 56240 23415
RH99 with local manual fault reset 220/240VAC 56173 22770 56273 24655
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC 56174 25110 56274 25885
RH197P with local manual or automatic fault reset 220/240VAC - 56507* 27870
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC - 56508* 63850
RH197P with local manual or automatic fault reset 220/240VAC - 56512** 61420
Sensitivity = 0.03- 30A & time delay= 0-4.5s 380/415VAC - 56513** 29550
Vigirex Sensors
Note: For vigirex relay with monitoring and communication facility, contact nearest sales office.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 50
ComPact- INS & INV Switch Disconnectors
For Low Voltage Circuit Control and Isolation - Incomers for Distribution Boards
• Conforms to IEC 60947-3/IS 13947 - 3
• Rated operational voltages 500V/690V
• Range 40A to 2500A
• Rated operational current @ AC 23A
• No deration upto 60° C
• Positive contact indication
• Common accessories with ComPact NSX/single auxillary contact
• Making capacity enhanced with ComPact NSX upstream
Unit MRP
Pole Description Rated Operational Current Reference
[`]
Interpact Range of Switch Disconnectors
40 A AC-23A 28900 6300
63 A AC-23A 28902 7610
100 A AC-23A 28908 8980
125 A AC-23A 28910 9790
160 A AC-23A 28912 10900
3-Pole
200 A AC-23A 31102 18950
250 A AC-23A 31106 20010
320 A AC-23A 31108 32590
400 A AC-23A 31110 36720
630 A AC-23A 31114 37780
40 A AC-23A 28901 7040
63 A AC-23A 28903 8330
100 A AC-23A 28909 9790
125 A AC-23A 28911 10910
160 A AC-23A 28913 12050
4-Pole
200 A AC-23A 31103 21160
250 A AC-23A 31107 22220
320 A AC-23A 31109 37750
400 A AC-23A 31111 38990
630 A AC-23A 31115 43700
lnterpact Changeover Systems (Complete Assembly)
100 A AC-23A 31140 60970
160 A AC-23A 31144 66360
200 A AC-23A 31142 72980
3-Pole 250 A AC-23A 31146 75010
320 A AC-23A 31148 124040
400 A AC-23A 31150 132430
630 A AC-23A 31154 134720
100 A AC-23A 31141 69540
160 A AC-23A 31145 76050
200 A AC-23A 31143 86120
4-Pole 250 A AC-23A 31147 89110
320 A AC-23A 31149 135290
400 A AC-23A 31151 139680
630 A AC-23A 31155 159900
Unit MRP
Description Reference
[`]
Accessories
Optional front extended rotary handle INS 250 - black handle (Switch Disconnector) LV431050 5605
Optional front extended rotary handle INS 320..630 - black handle (Switch Disconnector) 31052 7915
Optional front extended rotary handle INS 40..160 - black handle (Switch Disconnector) LV428941 2850
6 phase separators - INS100..160 28959 1250
6 phase separators - INS250 29329 1370
6 phase separators - INS400..630 LV432570 950
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 51
SDF Switch Disconnector Fuse units
se.com/in 52
FuPact Switch Disconnector Fuse units
• Complete Range from 32 to 630A in TP, TP+N & FP version suitable for
DIN/BS fuses.
• 4 breaks and 8 arcing points
• IP20 Fuse Protection Cover is standard
• Higher Mechanical and Electrical life.
Without Enclosure
Rated Operational DIN Type Unit MRP
Poles Description
Current Reference [`]
32 A 3P + N NX032TPNDI 3320
63 A 3P + N NX063TPNDI 4400
80 A 3P + N NX080TPNDI 8310
3P NX100TPXDI 9250
100 A
3P + N NX100TPNDI 9520
3P NX125TPXDI 10800
125 A
3P + N NX125TPNDI 11680
160 A 3P + N NX160TPNDI 12740
200A 3P + N NX200TPNDI 16360
3P NX250TPXDI 19280
250 A 3P + N NX250TPNDI 19670
4P NX250FPXDI 23570
315 A 3P + N NX315TPNDI 24360
400 A 3P + N NX400TPNDI 33330
3P NX630TPXDI 47830
630 A
3P + N NX630TPNDI 48480
Accessories/Spares
Reference Unit MRP
Description
[`]
NX032/NX063/NX080
Auxiliary contact for FuPact NXAA11 710
Handle operating mechanism (HOM) NX032...NX080 NXR1 640
NX100/NX125/NX160
Auxiliary contact for FuPact NXBA11 825
Fuse holder DIN for BS type NX100...NX160 NXHB21 315
Handle operating mechanism NX100...NX160 NXR2 1205
NX200
Auxiliary contact for FuPact NXBA11 825
Fuse holder for BS type NX200 NXHB22 330
Fuse holder for DIN NX200 NXHD22 375
Handle operating mechanism NX200 NXR2 1205
NX250/315/400
Auxiliary contact for FuPact NXBA11 825
Handle operating mechanism for NX250...NX400 NXR3 1245
NX630
Auxiliary contact for FuPact NXBA11 825
Note: For other versions please contact our nearest Sales Office.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 53
Future of Power Distribution
MasterPact MTZ
LV Circuit Breakers & Switch Disconnector
from 630A to 6300A
se.com/in 54
Built on the legendary performance and reliability of
the MasterPact range.
MasterPact MTZ circuit breakers prepare you for the future of power distribution with smart connectivity, remote
monitoring, and easy customization via digital modules.
• Intuitive EcoStruxure Power Device App smartphone • Seamless integration with building and energy
app for easy operation and maintenance management systems with EcoStruxure architectures
• Precise Class 1 power meter built in for energy- • Designed and tested to applicable standards for
saving capabilities ANSI, UL, and IEC
• Easy customization with digital modules • Low migration cost from MasterPact NT/NW
• Intuitive MicroLogicTM X control unit to MasterPact MTZ
• Easy installation using established architectures
se.com/in 55
MasterPact MTZ
MySE
Order your MasterPact MTZ online
EcoStruxure Power
BUILD AND Commision software
Commission and upgrade
COMMISSION easily with protection setting
and factory-acceptance test.
CUSTOMIZE OK
OR UPGRADE
GoDigital store
Purchase additional digital modules
for even more visibility and efficiency
over the MasterPact MTZ circuit
breaker life cycle.
se.com/in 56
MasterPact MTZ
Measurement Maintenance
Energy management is & Diagnostics
the challenge of present Optimal continuity of ser-
& future generations. vices as well as extended
To meet this requirement life of equipment is one of
MicroLogic X incorporates customers main concerns.
all the measuring functions For that purpose Micro-
of a power meter including Logic X integrates new
Energy Class 1 accuracy extended diagnosis and
third-party certified. assistance to maintenance.
PB116185_35-Copie
Protection
Improvement of the relia-
bility of MicroLogic X,
dual settings and additio-
nal facilities increase the
performance and the
flexibility of low voltage
systems of protection.
se.com/in 57
The Benchmark for Power Circuit Breakers around the world
MasterPact NT/NW
LV power circuit breakers 630 to 6300 A
se.com/in 58
MasterPact NT and NW
Ethernet ready MasterPact NT and NW breakers, setting the standard for performance, safety, connectivity and
built-in metering; all in optimized frame sizes
• Ethernet based monitoring, control, alarm notification for energy, asset and network management
• Built-in energy metering with combined accuracy class of 2% for improved energy efficiency
• MasterPact is suitable for heavy duty applications
Range Details:
• 630A to 6300A
• Breaking Capacity upto 150kA
• Fixed, Draw out type
• Flexible terminal orientation enables horizontal or vertical alignment changes in the field*
se.com/in 59
Micrologic Trip System Overview of functions
ATS Kit
Suitable for MasterPact NT/ NW ACB
This Kit comprises of :
• Adaptation fixture & set of two cables for mechanical interlocking
• IVE unit for Electrical Interlocking
• ACP control Plate
• UA/BA controller
*Note: For ATS with MasterPact NT/NW ACB, order 2 nos. of ACB’s with ready to close PF contact + 1 no. ATS Kit
se.com/in 60
The easy choice for reliable performance
EasyPact MVS
LV power circuit breakers and switch
disconnectors from 800 to 4000 A
se.com/in 61
EasyPact MVS
Range Details:
• Single frame for 800A to 4000A
• Fixed, Draw out type
• Entire Range Icu=Ics=Icw=50kA / 65kA for 1sec @440V
• Suitability for applications up to 690 V
• Flexible terminal orientation enables horizontal or vertical alignment changes in the field (except for 4000A)
se.com/in 62
ET/ETA/ETV Trip System
Voltage Metering
ZSI
Features
% Loading Bar Graph for each
phase
Thermal Memory
2 (L, I) 2L 2A 2V
Protection
6 (L,S,I,G) 6G 6A 6V
Unit MRP
Material Description Reference
[`]
EasyPact MVS Communication module .... EasyCom MVS21430 15620
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 63
EasyPact MVS Draw-out type Circuit breakers and
Switch Disconnectors 800-4000A
Draw-out ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚C
• Zone Selective Interlocking
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• Icu=Ics=Icw(1sec) = 50kA @ 440V AC
Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit (without display)
3P 3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating Unit MRP Unit MRP Unit MRP Unit MRP
Draw-Out Manual Electrical Manual Electrical
In (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 MVS08N3MW6L 247050 MVS08N3NW6L 318280 MVS08N4MW6L 310090 MVS08N4NW6L 381320
1000 MVS10N3MW6L 259540 MVS10N3NW6L 330770 MVS10N4MW6L 324870 MVS10N4NW6L 396100
1250 MVS12N3MW6L 288980 MVS12N3NW6L 360210 MVS12N4MW6L 359820 MVS12N4NW6L 431050
1600 MVS16N3MW6L 328440 MVS16N3NW6L 399670 MVS16N4MW6L 400750 MVS16N4NW6L 471980
2000 MVS20N3MW6L 441270 MVS20N3NW6L 512500 MVS20N4MW6L 541920 MVS20N4NW6L 613150
2500 MVS25N3MW6L 545530 MVS25N3NW6L 616760 MVS25N4MW6L 662920 MVS25N4NW6L 734150
3200 MVS32N3MW6L 659570 MVS32N3NW6L 730800 MVS32N4MW6L 808730 MVS32N4NW6L 879960
4000 MVS40N3MW6L 806680 MVS40N3NW6L 877910 MVS40N4MW6L 1036300 MVS40N4NW6L 1107530
Switch Disconnector version Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
Reduce `19300
(without trip unit) switch disconnector reference replace 6L by 0D i.e MVS08N3MW0D
ACB with ET6A trip unit Example : ACB reference with ET6G trip unit - MVS08N3MW6L. For
Add `9200
(LCD display with Current Metering) ACB reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MW6A
Note:
All draw-out type circuit breakers will be supplied with:
(i) Top and Bottom horizontal terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX)
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.
• The product label on all electrical operated breakers may have different reference number than above printed however both
references will have same functionalities. For example
- MVS08N3NW6L can be represented as MVS08N3EW6L
- MVS08N3NF6L can be represented as MVS08N3EF6L
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 64
EasyPact MVS Draw-out type Circuit breakers and
Switch Disconnectors 800-4000A
Draw-out ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚C
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• ET2L provides Overload & Short-circuit protections
• Icu=Ics=Icw(1sec) = 50kA @ 440V AC
Draw-out Type circuit breaker with Microprocessor based ET2L Trip Unit (without display)
3P 3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating Unit MRP Unit MRP Unit MRP Unit MRP
Draw-Out Manual Electrical Manual Electrical
In (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 MVS08N3MW2L 239650 MVS08N3NW2L 310880 MVS08N4MW2L 302690 MVS08N4NW2L 373920
1000 MVS10N3MW2L 252140 MVS10N3NW2L 323370 MVS10N4MW2L 317470 MVS10N4NW2L 388700
1250 MVS12N3MW2L 281580 MVS12N3NW2L 352810 MVS12N4MW2L 352420 MVS12N4NW2L 423650
1600 MVS16N3MW2L 321040 MVS16N3NW2L 392270 MVS16N4MW2L 393350 MVS16N4NW2L 464580
2000 MVS20N3MW2L 433870 MVS20N3NW2L 505100 MVS20N4MW2L 534520 MVS20N4NW2L 605750
2500 MVS25N3MW2L 538130 MVS25N3NW2L 609360 MVS25N4MW2L 655520 MVS25N4NW2L 726750
3200 MVS32N3MW2L 652170 MVS32N3NW2L 723400 MVS32N4MW2L 801330 MVS32N4NW2L 872560
4000 MVS40N3MW2L 799280 MVS40N3NW2L 870510 MVS40N4MW2L 1028900 MVS40N4NW2L 1100130
ACB with ET2A trip unit (LCD display with Example : ACB reference with ET2L trip unit - MVS08N3MW2L. For ACB
Add `4600
Current Metering) reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MW2A
AC* Same Philosophy for 3 Pole/ 4 Pole and Manual/ Electrical References
Note:
All draw-out type circuit breakers will be supplied with:
(i) Top and Bottom horizontal terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
• All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) & shunt release (MX).
• External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price.
• Any other accessories are optional at extra price.
• The product label on all electrical operated breakers may have different reference number than above printed however both
references will have same functionalities. For example
- MVS08N3NW6L can be represented as MVS08N3EW6L
- MVS08N3NF6L can be represented as MVS08N3EF6L
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 65
EasyPact MVS Fixed type Circuit breakers & Switch
Disconnectors 800-4000A
Fixed ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50˚ C
• Zone Selective Interlocking
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• Icu=Ics=Icw(1sec) =50kA @ 440V AC
Fixed Type circuit breaker with Microprocessor based ET6G Trip Unit (without display)
Rating 3P Fix Manual Unit MRP 3P Fix Electrical Unit MRP 4P Fix Manual Unit MRP 4P Fix Electrical Unit MRP
in (A) Reference [`] Reference [`] Reference [`] Reference [`]
800 MVS08N3MF6L 184220 MVS08N3NF6L 255450 MVS08N4MF6L 234220 MVS08N4NF6L 305450
1000 MVS10N3MF6L 201660 MVS10N3NF6L 272890 MVS10N4MF6L 254380 MVS10N4NF6L 325610
1250 MVS12N3MF6L 231780 MVS12N3NF6L 303010 MVS12N4MF6L 289580 MVS12N4NF6L 360810
1600 MVS16N3MF6L 257280 MVS16N3NF6L 328510 MVS16N4MF6L 332570 MVS16N4NF6L 403800
2000 MVS20N3MF6L 332250 MVS20N3NF6L 403480 MVS20N4MF6L 434210 MVS20N4NF6L 505440
2500 MVS25N3MF6L 405060 MVS25N3NF6L 476290 MVS25N4MF6L 511740 MVS25N4NF6L 582970
3200 MVS32N3MF6L 579820 MVS32N3NF6L 651050 MVS32N4MF6L 715390 MVS32N4NF6L 786620
4000 MVS40N3MF6L 714030 MVS40N3NF6L 785260 MVS40N4MF6L 895170 MVS40N4NF6L 966400
Switch Disconnector version Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For
Reduce `19300
(without trip unit) switch disconnector reference replace 6L by 0D i.e MVS08N3MF0D
ACB with ET6A trip unit (LCD display Example : ACB reference with ET6G trip unit - MVS08N3MF6L. For ACB
Add `9200
with Current Metering) reference with ET6A trip unit replace 6L by 6A i.e MVS08N3MF6A
Note:
All Fix type circuit breakers will be supplied with:
(i) horizontal / vertical terminal
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 4 C/O contacts.
(iv) door sealing frame- Escutcheon (CDP).
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 66
EasyPact MVS Fixed type Circuit breakers & Switch
Disconnectors 800-4000A
Fixed ACB
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• No derating up to 50° C
• Fully rated neutral with inbuilt protection
• Pre trip alarm & individual fault indicating LEDs
• Icu=Ics=Icw(1sec) =50kA @ 440V AC
Fixed Type circuit breaker with Microprocessor based ET2L Trip Unit (without display)
Rating in 3P Fix Manual Unit MRP 3P Fix Electrical Unit MRP 4P Fix Manual Unit MRP 4P Fix Electrical Unit MRP
(A) Reference [`] Reference [`] Reference [`] Reference [`]
800 MVS08N3MF2L 176820 MVS08N3NF2L 248050 MVS08N4MF2L 226820 MVS08N4NF2L 298050
1000 MVS10N3MF2L 194260 MVS10N3NF2L 265490 MVS10N4MF2L 246980 MVS10N4NF2L 318210
1250 MVS12N3MF2L 224380 MVS12N3NF2L 295610 MVS12N4MF2L 282180 MVS12N4NF2L 353410
1600 MVS16N3MF2L 249880 MVS16N3NF2L 321110 MVS16N4MF2L 325170 MVS16N4NF2L 396400
2000 MVS20N3MF2L 324850 MVS20N3NF2L 396080 MVS20N4MF2L 426810 MVS20N4NF2L 498040
2500 MVS25N3MF2L 397660 MVS25N3NF2L 468890 MVS25N4MF2L 504340 MVS25N4NF2L 575570
3200 MVS32N3MF2L 572420 MVS32N3NF2L 643650 MVS32N4MF2L 707990 MVS32N4NF2L 779220
4000 MVS40N3MF2L 706630 MVS40N3NF2L 777860 MVS40N4MF2L 887770 MVS40N4NF2L 959000
ACB with ET2A trip unit (LCD display Example : ACB reference with ET2L trip unit - MVS08N3MF2L. For ACB
Add `4600
with Current Metering) reference with ET2A trip unit replace 2L by 2A i.e MVS08N3MF2A
Note:
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 67
EasyPact MVS Accessories
Unit MRP
Component Specification Reference
[`]
Gear Motor (MCH)
100/130 V 47893
AC 50/60 Hz 200/240 V 47894
380/415 V 47896
24/30 V 47888 55230
48/60 V 47889
DC
100/125 V 47890
200/250 V 47891
Closing Release (XF)
24/30 V DC 33659
48/60 V DC 33660
AC 50/60 Hz DC 100/130 V AC/DC MVS15511 8040
200/250 V AC/DC MVS15512
380/480 V AC MVS15513
Opening Release (MX)
24/30 V DC, 24 V AC 33659
8040
48/60 V DC, 48 V AC 33660
AC 50/60 Hz DC 100/130 V AC/DC 33661 7980
200/250 V AC/DC 33662
8040
380/480 V AC 33664
Terminal Block
For drawout circuit breaker 47849 300
Under Voltage Release (MN)
24/30 V DC, 24 V AC 33668
48/60 V DC, 48 V AC 33669
AC 50/60 Hz DC 100/130 V AC/DC 33670 8040
200/250 V AC/DC 33671
380/480 V AC 33673
MN Delay Unit
48/60 V AC/DC 33680
100/130 V AC/DC 33681
Rr (adjustable) 11690
200/250 V AC/DC 33682
AC 50/60 Hz DC
380/480 V AC/DC 33683
100/130 V AC/DC 33684
R (non-adjustable) 10890
200/250 V AC/DC 33685
ON/OFF Indication Contacts (Additional OF contact)
1 additional block of 4 contacts 47887 7090
Door Interlock (VPECD)/1 part
On right hand side of chassis 47914 3860
Operation Counter
Operation Counter CDM 48535 10960
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 68
EasyPact SPS
800-1600A
ET2.0 ET6G
Trip System Trip System
se.com/in 69
EasyPact SPS Draw-out type Circuit breakers and
Switch Disconnectors 800-1600A
• All EasyPact SPS Air Circuit Breakers are equipped with terminal adaptors
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• Fully rated neutral with inbuilt protection
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• ET2B provides Overload & Short-circuit protections
• Short circuit breaking capacity 50kA @ 440V AC
Draw-out Type circuit breaker with Microprocessor based ET6G Trip Unit
3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit MRP Unit MRP Unit MRP Unit MRP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW6L 203250 SPS08F3PEW6L 255130 SPS08F4PMW6L 254870 SPS08F4PEW6L 306760
1000 SPS10F3PMW6L 212960 SPS10F3PEW6L 264850 SPS10F4PMW6L 269620 SPS10F4PEW6L 321510
1250 SPS12F3PMW6L 238200 SPS12F3PEW6L 290080 SPS12F4PMW6L 303800 SPS12F4PEW6L 355680
1600 SPS16F3PMW6L 268710 SPS16F3PEW6L 320600 SPS16F4PMW6L 343880 SPS16F4PEW6L 395770
Draw-out Type circuit breaker with Microprocessor based ET2B Trip Unit
3P Draw-Out 4P Draw-Out 4P Draw-Out
Rating 3P Draw-Out Unit MRP Unit MRP Unit MRP Unit MRP
Electrical Manual Electrical
in (A) Manual Reference [`] [`] [`] [`]
Reference Reference Reference
800 SPS08F3PMW2B 200940 SPS08F3PEW2B 252830 SPS08F4PMW2B 252570 SPS08F4PEW2B 304450
1000 SPS10F3PMW2B 210660 SPS10F3PEW2B 262530 SPS10F4PMW2B 267320 SPS10F4PEW2B 319190
1250 SPS12F3PMW2B 235890 SPS12F3PEW2B 287780 SPS12F4PMW2B 301500 SPS12F4PEW2B 353380
1600 SPS16F3PMW2B 266410 SPS16F3PEW2B 318290 SPS16F4PMW2B 341580 SPS16F4PEW2B 393460
Note:
All draw-out type circuit breakers will be supplied with:
(i) Vertical-vertical terminations.
(ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 2 C/O contacts.
(iv) Safety shutters on Chassis & door sealing frame- Escutcheon (CDP).
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 70
EasyPact SPS Fixed type Circuit breakers and
Switch Disconnectors 800-1600A
• All EasyPact SPS Air Circuit Breakers are equipped with terminal adaptors
• Conforms to IS/ IEC 60947-2 & 3
• Microprocessor based ET trip systems with thermal memory
• Fully rated neutral with inbuilt protection
• ET6L provides Overload, Short-circuit, Instantaneous & Earth-fault protections
• ET2B provides Overload & Short-circuit protections
• Short circuit breaking capacity 50kA @ 440V AC
Fixed Type circuit breaker with Microprocessor based ET6G Trip Unit
3P 3P 4P 4P
Rating Unit MRP Unit MRP Unit MRP Unit MRP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF6L 156120 SPS08F3PEF6L 208010 SPS08F4PMF6L 189810 SPS08F4PEF6L 241700
1000 SPS10F3PMF6L 164370 SPS10F3PEF6L 216250 SPS10F4PMF6L 203800 SPS10F4PEF6L 255680
1250 SPS12F3PMF6L 189510 SPS12F3PEF6L 241400 SPS12F4PMF6L 236440 SPS12F4PEF6L 288330
1600 SPS16F3PMF6L 219450 SPS16F3PEF6L 271340 SPS16F4PMF6L 270300 SPS16F4PEF6L 322180
Fixed Type circuit breaker with Microprocessor based ET2B Trip Unit
3P 3P 4P 4P
Rating Unit MRP Unit MRP Unit MRP Unit MRP
Fixed Manual Fixed Electrical Fixed Manual Fixed Electrical
in (A) [`] [`] [`] [`]
Reference Reference Reference Reference
800 SPS08F3PMF2B 153820 SPS08F3PEF2B 205700 SPS08F4PMF2B 187510 SPS08F4PEF2B 239380
1000 SPS10F3PMF2B 162060 SPS10F3PEF2B 213950 SPS10F4PMF2B 201490 SPS10F4PEF2B 253380
1250 SPS12F3PMF2B 187210 SPS12F3PEF2B 239100 SPS12F4PMF2B 234130 SPS12F4PEF2B 286020
1600 SPS16F3PMF2B 217140 SPS16F3PEF2B 269030 SPS16F4PMF2B 268000 SPS16F4PEF2B 319870
Note: All Fixed type circuit breakers will be supplied with: (i) Vertical-vertical terminations. (ii) 1 No. Electrical fault indication Contact (SDE).
(iii) 1 No. Auxiliary contact block (OF) with 2 C/O contacts.
All switch disconnectors are without protection | All electrical operated breakers are supplied with motor mechanism (MCH), closing coil (XF) and shunt release
(MX). | External Neutral CT required for highly un-balanced TP-N system has to be ordered at extra price. | Any other accessories are optional at extra price.
Accessories
Unit MRP
Pole Description Rated Operational Current Reference
[`]
Gear Motor (MCH)
100/130 V 33176
AC 50/60 Hz 200/240 V 33177
277/415 V 33179
24/30 V 33185 55230
48/60 V 33186
DC
100/125 V 33187
200/250 V 33188
Terminal Block
For Fixed circuit breaker 47074 350
For Drawout circuit breaker 33098 335
ON/OFF Indication contacts (OF) 1Part
Changeover contact 6A 240V 47076 1430
Ready to close contact
Changeover contact 5A 240V 47080 3660
Door interlock (VPECD)/1 part
Right side of chassis 33172 5430
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 71
The 7000 SERIES Automatic Transfer Bypass-Isolation Switch is
intended for critical applications where continuous power is required
Allows bypass-isolation without load interruption
Primary transfer switch can be inspected, tested, and maintained
without interrupting power to the load
Transfer switch and bypass transfer switch have identical electrical ratings
Range: 150 to 4000 amps
Draw-out design allows for easy transfer switch maintenance
Open Transition (OTTS), Closed Transition (CTTS) and Delayed Transition
(DTTS) Designs
se.com/in 72
Series 7000/300, Automatic Transfer Switch (ASCO)
7000/300 Series Power Transfer Switches are available in open and enclosed variants,
ranging from 30 to 4000 amps (LV) & 1200 to 3000A (MV) with wide range of accessories.
All switching configurations (OTTS, DTTS, CTTS) are available with optional integrated
bypass-isolation switch.
Confirming to UL 1008 Engine Start/Stop, AMF Logic & Time Delay Setting
Fast & Consistent Transfer (Less than 100ms) Programmable Daily/Weekly Engine Exerciser
Single Solenoid True Double throw Design 4 Line LCD + LED Display
High Withstanding & Closing-On Fault Currents (WCR) 99 Events Log & Diagnostics with Date/Time
Neutral Overlap to eliminate Voltage Transients Statistical ATS System Monitoring Information
In-Phase Monitor to avoid Motor Inrush current Communication Compatible (Modbus/Ethernet)
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 73
Series 230, Automatic Transfer Switch (ASCO)
Unit MRP
Frame Rating(Amp) Controller Type Reference Poles
[[`]
C300
16 A2ADTLB30016KB 39150
32 A2ADTLB30032KB 40020
A2ADTL 4P
Unit Unit
Rating
Frame Controller Type Reference MRP Controller Type Reference MRP Poles
(Amp)
[[`] [[`]
100 C1000 B2ADTLB30100KD 57420 C2000 B2ADTLB30100KE 92220
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 74
WOTPC, Automatic transfer switch
Rating (amps) Poles Reference Unit MRP [`] Poles Reference Unit MRP [`]
*above references are with vertical termination, for horizontal terminal please contact customer care
WOTPC Accessories:
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 75
Launching soon
Advanced transfer switch to maximize
se.com/in
se.com/in 76
Launching soon
Transfer switching Equipment
se.com/in
se.com/in 77
EasyPact TVS
The Easy choice for simplicity and flexibility
l 3 Pole and 4 Pole Power Contactor New
l Control Relays A2L certified
upto 50A
l Thermal Overload Relay for HVAC
applications
l Circuit Breaker for Motor Protection
l Accessories
se.com/in 78
EasyPact TVS
[Ie] Rated Operational Current Motor Power at 415V, 3Ph, 50Hz Auxiliary Contacts Unit MRP
Frame Reference
AC-1 AC-3 HP kW NO NC [`]
- 1 LC1E0601*
20 6 3 2.2 1190
1 - LC1E0610*
- 1 LC1E0901*
25 9 5.5 4 1220
1 - LC1E0910*
- 1 LC1E1201*
FRAME-1 25 12 7.5 5.5 1390
1 - LC1E1210*
- 1 LC1E1801*
32 18 12 9 1605
1 - LC1E1810*
- 1 LC1E2501*
36 25 15 11 2190
1 - LC1E2510*
- 1 LC1E3201*
50 32 20 15 4585
1 - LC1E3210*
- 1 LC1E3801*
FRAME-2 50 38 25 18.5 5420
1 - LC1E3810*
- 1 LC1E40B01**
50 40 29 22 5780
1 - LC1E40B10**
60 40 29 22 1 1 LC1E40* 7180
FRAME-3 70 50 34 25/30 1 1 LC1E50* 8730
80 65 50 37 1 1 LC1E65* 11830
[Ie] Rated Operational Current Motor Power at 415V, 3Ph, 50Hz Auxiliary Contacts Unit MRP
Frame Reference
AC-1 AC-3 HP kW NO NC [`]
110 80 60 45 1 1 LC1E80* 15380
FRAME-4
120 95 60 45 1 1 LC1E95* 18440
150 120 75 55 1 1 LC1E120* 21965
FRAME-5
200 160 120 90 1 1 LC1E160* 29005
250 200 150 110 - - LC1E200* 39920
FRAME-6
300 250 175 132 - - LC1E250* 52610
320 300 215 160 - - LC1E300* 62980
FRAME-7
500 400 295 220 - - LC1E400* 78600
FRAME-8 700 500 375 280 - - LC1E500* 110710
FRAME-9 1000 630 500 375 - - LC1E630* 157180
* Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
se.com/in 79
EasyPact TVS
* Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
4 Pole Contactors
LC1E0600*…. LC1E1800* LAEX1T**
LC1E2500*…. LC1E3800* LAEX2T**
LC1E4000*…..LC1E9500* LAEX4T**
Control Contactors
CAE* LAEX12**
LC1E0600*…9500* 50/60 Hz B7 F7 - -
LC1E0600*…9500* 50 Hz/ Wide Band - - M5WB N5WB
Control relay CAE 50 Hz B5 F5 M5 N5
Note:
For non standard voltages (Except 110 and 220 V AC) please consult Customer Care for prices
* Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 80
EasyPact TVS
Unit MRP
Description For Use with Coil Voltage Reference
[`]
LC1E06...E95 24..48V AC LAERCE 1460
Surge suppressor*
LC1E06...E95 110..240V AC LAERCU 885
*For higher rating contactors, contact nearest sales office
Unit MRP
Description For Use with Reference
[`]
LC1E06..E65 & LC1E0600*..E3800* LAEM1 790
LC1E80/E95 & LC1E4000*…LC1E9500* LAEM4 2570
Mechanical Interlock
LC1E120..E160 LAEM5 4795
LC1E200/E250 LAEM6 4885
*Reference to be completed by adding coil voltage
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 81
EasyPact TVS
Unit MRP
Thermal Protection Adjustment Range For Use with Contactor Reference
[`]
LRE
0.25...0.4 E06...E38 LRE03
0.4...0.63 E06...E38 LRE04
0.63...1 E06...E38 LRE05
1...1.6 E06...E38 LRE06
1.6...2.5 E06...E38 LRE07
2025
2.5...4 E06...E38 LRE08
4...6 E06...E38 LRE10
5.5...8 E09...E38 LRE12
7...10 E09...E38 LRE14
9...13 E12...E38 LRE16
12...18 E18...E38 LRE21 2240
16...24 E25...E38 LRE22 2590
23...32 E25...E38 LRE32 3465
30...38 E38 LRE35 3900
17...25 E40...E95 LRE322
23...32 E40...E95 LRE353
4405
30...40 E40...E95 LRE355
37...50 E50...E95 LRE357
48...65 E65...E95 LRE359 5775
Unit MRP
Thermal Protection Adjustment Range For Use with Contactor Reference
[`]
LRE
55...70 E80...E95 LRE361 6845
63...80 E80...E95 LRE363
7145
80...104 E95 LRE365
51...81 E120...E300 LRE480
62...99 E120...E300 LRE481
84...135 E120...E300 LRE482
13380
124...198 E160...E300 LRE483
146...234 E200...E300 LRE484
174...279 E250...E300 LRE485
208...333 E300 LRE486 14580
258…414 E300…E400 LRE487 17735
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 82
EasyPact TVS
Unit MRP
Description Mounting Range Reference
[`]
Electric Trips
110…115V 50Hz GZ1AU115
Undervoltage 220…240V 50Hz GZ1AU225
RH Side Mounted 380…400V 50Hz GZ1AU385 On Request
110…115V 50Hz GZ1AS115
Shunt trip
220…240V 50Hz GZ1AS225
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 83
TeSys
> Control > Protect > Power > Active
NEW
se.com/in 84
Start smart. Run smart.
With TeSys motor controls.
Stay smart with the world's best-selling motor control solutions from
the inventor of the world's first contactor - Schneider Electric™.
For almost a century, TeSys motor controls have driven the industry with
innovations in motor protection, monitoring, and control.
It started with the introduction of the industry's first BAR Wherever you are and anywhere your projects come
contactor in 1924, and today, the legacy of innovation is together, you can trust Schneider Electric and TeSys
built into every TeSys motor control device. contactors, circuit breakers, relays, and switches for
Best-in-class safety and reliability, plug-and-play unmatched reliability, complete compatibility with
architecture, and flexible functionality mean TeSys motor international standards, and the robust support of the
control solutions can meet your requirements across a wide Schneider Electric global supply network.
range of applications, from the most common to the most Start smart, run smart and stay smart with TeSys motor
advanced. controls.
1st BAR 1st Enclosed 1st Modular TeSys D 1st Modular GV3 MSP TeSys D TeSys TeSys TeSys
Contactor Motor Starter Contactor Contactor 3 in 1 with EverLink Green Island Giga Deca
Motor Starter
1924 1935 1973 2000 2004 2008 2016 2019 2021 2021
se.com/in 85
Superior safety for all industries
TeSys motor controls come with all of the isolation, protection and emergency handling you need to comply with
international codes. High-contrast covers identify safety-critical devices to prevent inadvertent manual operation. Every
TeSys contactor is both mechanically linked and equipped with mirror contacts for safety applications and wherever
auxiliary contact state reliability is critical.
Packaging Oil and Gas Water and Wastewater Food and Beverage
Keep pace with the most Keep your employees and Optimize the treatment and Serve your customers with
demanding, high-end assets safe and improve delivery of safer water by environmentally friendly
packing applications with uptime in onshore and reducing energy usage and products to improve
our solutions offshore applications: lowering operating costs. sustainability, efficiency, and
pipeline operations: flexibility, allowing you to
LNG and natural gas adapt to changing customer
processing: and refining and habits.
petrochemical applications.
Scan or click on
the QR code
se.com/in 86
TeSys Range
NEW
TeSys K Series
The essential line for motors up to 7.5kW/16A direct on
TeSys K series of Motor Starters
se.com/in 87
TeSys Control
TeSys K
Control Relays - K Model (AC & DC Control)
• Conformance IEC, UL, CSA, CE Marking
• Inbuilt 4 auxiliary contacts
• 10A thermal rating
• Available with AC (50/60Hz Dual frequency), DC & DC low consumption coil
options
[Ie] Rated
Motor Power Unit MRP DC Control Unit MRP
Operational Auxiliary Contacts AC Control Reference
(kW) [`] Reference(5) [`]
Current (A)
1NC LC1K0601* LP1K0601**
6 3 1355 2095
1NO LC1K0610* LP1K0610**
1NC LC1K0901* LP1K0901**
9 5.5 1415 2280
1NO LC1K0910* LP1K0910**
1NC LC1K1201* LP1K1201**
12 7.5 1600 2645
1NO LC1K1210* LP1K1210**
1NC LC1K1601* - -
16 10 1890
1NO LC1K1610* - -
(5) For low consumption offer, please contact regional sales office
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 88
TeSys Control
TeSys K
Accessories - K Model
Unit MRP
Description Mounting Contacts Reference
[`]
2NC LA1KN02 660
1NO + 1NC LA1KN11 605
2NO LA1KN20 660
4NC LA1KN04
Auxiliary contact block Front
1NO + 3NC LA1KN13
2NO + 2NC LA1KN22 1025
3NO + 1NC LA1KN31
4NO LA1KN40
Unit MRP
Description Control Voltage Range Reference
[`]
24..48V AC/DC 1..30S LA2KT2E(1)
On Delay Electronic Timer 3350
110..240V AC 1..30S LA2KT2UA(1)
Unit MRP
Description Coil Voltage Reference
[`]
Surge Suppressor - RC Ciruit 220..250V AC LA4KA1U*
Surge Suppressor - Varistor 130..250V AC/DC LA4KE1UG* 1045
Surge Suppressor - Varistor 50..129V AC/DC LA4KE1FC*
* Lot size 5
(1) Front mounted with common point changeover contact
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 89
TeSys Control
TeSys Deca NEW
The next-generation TeSys Deca series motor starters offer a reliable and robust solution for a faster machine
time-to-market. It has a new modern look & feel and is designed to meet the requirements of Electro domestic
applications. Ease of operation and reliability is guaranteed with the new multi-standard screws. Digital
customer experience is enhanced with a QR embedded from product to packaging.
* Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 90
TeSys Control
TeSys Deca NEW
* Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
Type Voltage 24V DC Low consumption 24-60V AC/DC 48-130V AC/DC 100-250V AC/DC
TeSys Deca Green# LC1D40A-80A, LC1DT60A-DT80A BBE BNE EHE KUE
Note: Please contact Customer Care for 4 Pole AC coil contactor details
For Non standard coil voltage prices please contact customer care
(1) For current rating and ref please contact Customer Care
(2) Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 91
TeSys Deca Green
The Revolutionary Electronic Coil Contactor
10X Reduction Only 3 references to cover the complete voltage range for
in references AC and DC
High uptime thanks to wide band coil with high resistance Scan to see TeSys
SEMIF47 to voltage surges/SEMIF47 conform Deca Green under
voltage performance.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 92
TeSys Control
TeSys Deca NEW
* Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 93
TeSys Control
TeSys Deca NEW
Unit MRP
Description For use with Reference
[`]
Power connection accessories
Terminal block For supply to one or more GV2 G busbar sets GV1G09 2130
GV2G245
Set of 63A busbars for 2 contactors LC1D09…D18 or D25…D38 GV2G245 1865
parallelling of contactors 4 contactors LC1D09…D18 or D25…D38 GV2G445 2935
Set of 115A busbars for 2 contactors LC1D40A…D80A GV3G264 3350
parallelling of contactors 3 contactors LC1D40A…D80A GV3G364(1) 1790
For circuit breakers GV3P** & GV3L** and contactors LC1 D40A…
Set of S-shape busbars GV3S 1340
D65A
**Not applicable for GV3P/GV3L 73A and 80A
GV1G09
Unit MRP
Description For use with Reference
[`]
LC1D09 to D38(1) LAD9V2 745
Mechanical interlock
LC1D40A to D65A(1) LAD4CM 1515
LC1D80 and D95 ( for AC control voltage) LA9D4002 3315
LC1D80 and D95 (for DC control voltage)(2) LA9D8002 4935
LC1D115 and D150(2) LA9D11502 5005
(1) With this set of busbars, any one contactor can be supplied directly by its EverLink® double cage power terminal block.
The other two contactors are supplied by the busbar set. The 115A limitation is therefore applied to these two contactors.
(2) With electrical interlock GV3S
Unit MRP
Description For use with Reference
[`]
Power Connection for Reversing
Kit Comprising : LAD9V5 +
LC1D09 to D38 1385
1. A set of parallel bars LAD9V6
2. A set of reverser bars. LC1D40A to D80A LA9D65A69 3220
LC1D80 and D95 ( for AC control voltage) LA9D8069 6890
LC1D80 and D95 (for DC control voltage) LA9D8069 6890
LC1D115 and D150 LA9D11569 11460
LA9 D8069
Unit MRP
Description For use with Reference
[`]
Reversing Kit
Kit Comprising :
1. A mechanical interlock LAD 9V2 with electrical interlocking LAD 9V1 LC1D09 to D38 LAD9R1V 1545
2. A set of power connections LAD 9V5 (parallel) and LAD 9V6 (reversing).
Kit Comprising :
1. A mechanical interlock LAD 9V2 without electrical interlocking LC1D09 to D38 LAD9R1 1410
2. A set of power connections LAD 9V5 (parallel) and LAD 9V6 (reversing).
Kit Comprising : LAD9R1
1. A mechanical interlock LAD 4CM LC1D40A to D80A LAD9R3 3675
2. A set of power connections LA9 D65A69.
Unit MRP
Description For use with Reference
[`]
Star Delta Kit
Time delay contact block LAD S2 (LC1D09…D80), LC1D09 and D12 LAD91217 5810
Power circuit connections (LC1D09…D80),
LC1D18 to D32 LAD93217 7470
Hardware required for fixing the contactors onto the mounting plate
(LC1D80) LC1D40A and D50A LAD9SD3 15100
LC1D80 LA9D8017 16765 LAD9R3
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 94
TeSys Control
TeSys Deca NEW
Unit MRP
Description Time Delay Range Timer Type Reference
[`]
On delay timer(1) (2) 15...30 s on delay LA4DT2U
5140
On delay timer(1) (2) 0.1...2 s on delay LA4DT0U
On delay timer (1) (2)
25...500 s on delay LA4DT4U 5760
Relay interface module - 24V DC(1) (2) - - LA4DFB 4735
(1) For LC1 D09...38A (3P, AC coils only) add mounting adaptor LAD4BB and for LC1 D40A...65A (3P, AC coils only), add mounting adaptor LAD4BB3.
(2) For LC1D80...150 (3P), direct mounting, for 100-250V AC Coils only.
Unit MRP
Description For use with Reference
[`]
TeSys Deca Model Mechanical Latch Blocks
LC1D09...D38 (a or c)
LC1DT20...DT40 (a or c)
LAD6K10* 6180
LC1D40A...D65A (3P a or c)
LC1DT60A and DT80A (4P a or c)
Front, Clip-on LC1D80...D150 (3P a)
LC1D80 and D115 (3 P c)
LC1D80 (4 P a) LA6DK20* 6450
LC1D80 and D115 (4 P a)
LP1D80 and LC1D115 (4 P c)
* Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
AC Coils
CAD, LC1-D09...D38, DT20..40 LXD1*
LC1D40A, D50A, D65A & LC1DT60A, DT80A LXD3*
D80 & D95 (3P & 4P) LX1D6*
LC1-D115,D150 LX1D8*
DC Coils
LC1-D80-D95 LX4D7**
LC1-D115, D150 LX4D8**
* Reference to be completed by adding coil voltage code and recommended to check availability with Customer Care team
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 95
TeSys Control
TeSys Deca NEW
Accessories
Unit MRP
Description For use With Contacts Reference
[`]
Add On Blocks
1NO + 1NC LADN11
500
2NO LADN20
2NC LADN02 725
LC1D09 …LC1D150 2NO + 2NC LADN22 900
Front Mounted
Additional instantaneous & LC1F* 4NC LADN04 1205
auxiliarycontact blocks 4NO LADN40
1NO + 3NC LADN13 900
3NO + 1NC LADN31
LC1D80..LC1D95 1NO LADN10
Front Mounted 405
& LC1F 1NC LADN01
Unit MRP
Description Contacts Reference
[`]
Add On Blocks
Additional instantaneous Side 1NO + 1NC LAD8N11
1740
auxiliary contact blocks Mounted (1) 2NO LAD8N20
1NO + 1NC 0.1..3s LADT0
1NO + 1NC 0.1..30s LADT2 3595
ON delay
Pneumatic 1NO + 1NC 10..180s LADT4
timer blocks 1NO + 1NC 1..30s (2) LADS2 3835
front mounted 1NO + 1NC 0.1 ..3s LADR0
OFF delay 1NO + 1NC 0.1 ..30s LADR2 3595
1NO + 1NC 10..180s LADR4
(1) Suitable for mounting on TeSys Deca range AC Coil Contactors and Control Relays only
(2) With Switching time of 40 ms between opening of the NC contact and closing of the NO contact recommended for Star - Delta Starters
Accessories compatibility
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 96
TeSys Control
TeSys Deca NEW
Accessories
Unit MRP
Description For use with Reference
[`]
For Contactor D115/150
Contacts set - 3P LC1D115 LA5D1158031 20240
Contacts set - 3P LC1D150 LA5D150803 20980
Contacts set - 4P LC1D1150046 LA5D115804 27900
Unit MRP
Product Compatibility Fixing Control Circuit Voltage Suppressor Type Reference
[`]
Coil Suppressor Modules
LC1D12...D25 (4P) 110...240V AC RC Circuit AC LA4DA1U 1585
LC1D12...D25 (4P) 12...250V DC Diode DC LA4DC1U 1775
24...48V AC Varistor AC/DC LAD4VE
LC1D09...D38, LC2D09...D38, 1535
24...48V AC 400Hz RC Circuit AC LAD4RCE
LC1DT20...DT40, LC2DT20...DT40 (3P)
50...127V AC 200Hz RC Circuit AC LAD4RCG 1390
110...240V AC 100Hz RC Circuit AC LAD4RCU
CAD 1535
110….250V AC Varistor AC/DC LAD4VU
Screw
24...250V DC Diode DC LA4DC3U 1585
110...250V AC Varistor AC/DC LA4DE2U
1515
24...48V AC 400Hz RC Circuit AC LA4DA2E
LC1D80, LC1D95, LC2D80, LC2D95 (3P)
50...127V AC 200Hz RC Circuit AC LA4DA2G 2390
LC2D80 (4P), LC1D40008, LC1D65008
110...240V AC 100Hz RC Circuit AC LA4DA2U 1585
380...415V AC 150Hz RC Circuit AC LA4DA2N 2390
24...48V DC Varistor AC/DC LA4DE3E 1585
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 97
TeSys Control
TeSys Deca NEW
Built in Safety
TeSys Ultra motor starters are certified according to IEC 60947-4-1 for safety applicarions thanks to integrated mirror contact
Unit MRP
Description For use with Reference
[`]
Red Cover (For safety chain indication) LC1D09…D65A and DT20 .. DT80A LAD9ET1S 715
Auxiliary Contact block with red front face- for
2NO + 2NC LADN22S 1020
safety chain indication
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 98
New TeSys Giga
Contactors and Relays
Futuristic ready…
New generation of high power contactors..115-800 A (AC-3)
Advanced contact wear diagnostic for predictive maintenance
Modular design for easy maintenance and short down times
Compact design for less installation space consumption
Less product references for easier selection and reduced inventory
Right choice for a wide range of demanding applications!!
se.com/in/TeSys
se.com/in 99
TeSys Control
TeSys Giga NEW
A comprehensive range of TeSys Giga Contactors that are available in ‘Advanced’ and ‘Standard’ versions, in 3 sizes,
covering several ratings.
A common range of auxiliary contacts and accessories, enabling high flexibility and simplicity.
(1) 630A and 800A (AC-3) and 1050A (AC-1) contactors shall be launched in Q2 2022.
se.com/in 100
TeSys Control
TeSys Giga NEW
[Ie] Rated Motor Power (Long Life) AC-3 Standard version Unit MRP Advanced version Unit MRP
Operational Current AC-1 kW HP A Reference [`] Reference [`]
250 59 80 115 LC1G115***N 28000 LC1G115***A
275 80 110 150 LC1G150***N 35700 LC1G150***A
305 100 135 185 LC1G185***N 44245 LC1G185***A
330 110 150 225 LC1G225***N 47610 LC1G225***A
On Request
385 140 190 265 LC1G265***N 57970 LC1G265***A
440 180 245 330 LC1G330***N 70105 LC1G330***A
550 220 300 400 LC1G400***N 84730 LC1G400***A
700 280 380 500 LC1G500***N 117540 LC1G500***A
(1) 630A and 800A (AC-3) and 1050A (AC-1) contactors shall be launched in Q2 2022.
Unit MRP
Mechanical interlock between contactors(1) Reference
[`]
For Use With Contactor
Between Identical contactor frames LA9G970 2273
Between LC1G(265-500) and LC1G(185-225) LA9G971 2273
LC1G630 to LC1G800 and LC1G265 to LC1G500 LA9G972 on request*
(1) Maximum 3 auxiliary contacts can be installed between 2 contactors with mechanical interlock kit.
* to be launched in Q2 2022
se.com/in 101
TeSys Control
TeSys F
TeSys F Power Contactors (3 Pole AC/DC Control)
• Conformity to International Standards – IEC, UL, CSA, CE
• High electrical life
• Type 2 Co-ordination Charts available (upon request)
• Common accessories as TeSys Deca
• Rating : 115 - 2600A, AC/DC Coils, special Hoisting application coils
• Shock Proof version and Magnetic latching contactor available
Note:
• Contactor reference does not include coil. Contactor coil & aux. contacts to be ordered separately.(Coil includes 1NO contact)
• Please select coils from table on next page (Page-103).
Note:
• Contactor reference does not include coil. Contactor coil & aux. contacts to be ordered separately.(Coil includes 1NO contact)
• Power terminals may be protected by the addition of shrouds, to be ordered separately.
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation
accessories, ,andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 102
TeSys Control
TeSys F
TeSys F Coils
Unit MRP DC Coil Unit MRP
Product Compatibility AC Coil Reference
[`] Reference(2) [`]
LC1F115, LC1F150 LX9FF* LX4FF**
LC1F185, LC1F225 LX9FG* LX4FG**
LC1F265, LC1F330 LX1FH* LX4FH**
LC1F400 LX1FJ* LX4FJ**
LC1F500 LX1FK* On Request LX4FK** On Request
LC1F630 LX1FL* LX4FL**
LC1F800 (1)
LX4F8**
LC1F1000, LC1F1700, LC1F2100 LX1FK*(3)
LC1F2600 LX1FL*(3)
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation
accessories, ,andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 103
TeSys Control
TeSys F
Accessories - TeSys Deca and TeSys F
Unit MRP
Description Contacts Reference
[`]
Add On Blocks
Additional instantaneous Side 1NO + 1NC LAD8N11
1740
auxiliary contact blocks Mounted (1) 2NO LAD8N20
1NO + 1NC 0.1..3s LADT0
1NO + 1NC 0.1..30s LADT2 3595
ON delay
Pneumatic 1NO + 1NC 10..180s LADT4
timer blocks 1NO + 1NC 1..30s (2) LADS2 3835
front mounted 1NO + 1NC 0.1 ..3s LADR0
OFF delay 1NO + 1NC 0.1 ..30s LADR2 3595
1NO + 1NC 10 ..180s LADR4
(1) Suitable for mounting on D Model range AC Coil Contactors and Control Relays only
(2) With Switching time of 40 ms between opening of the NC contact and closing of the NO contact recommended for Star - Delta Starters
* Suitable for 80A, 95A & Model F contactors only
Unit MRP
For Use With TeSys F Contactors Reference
[`]
Mechanical Interlocks (1) - Horizontally Mounted
LC1F115, LC1F150, LC1F1154, LC1F1504 LA9FF970
LC1F185, LC1F1854, LC1F225, LC1F2254 LA9FG970
On Request
LC1F265, LC1F330, LC1F400, LC1F500, LC1F2654, LC1F3304, LC1F4004, LC1F5004 LA9FJ970
LC1F630, LC1F6304, LC1F800 LA9FL970
(1) For assembly of 3/4 pole 2 contactors of identical rating. To obtain electrical interlocking, please order 2 contact blocks LADN11
All power connections are to be made by the user.
Main Contact Sets*
LC1F115, LC1F150 LA5FF431
LC1F185, LC1F225 LA5FG431
LC1F265 LA5FH431
LC1F330, LC1F400 LA5F400803 On Request
LC1F500 LA5F500803
LC1F630 LA5F630803
LC1F800 LA5F800803
* For 3 Pole contactor (per pole: 2 fixed contacts and 1 moving contact, 2 deflectors, 1 backplate, fixing screws & washers.)
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation
accessories, ,andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 104
TeSys Special Purpose Contactor
# Contactor recommended upto 6 steps. For over 6 steps it is recommended to use chokes
* Reference to be completed by adding coil voltage code
LC1DFK....DWK, 50/60Hz F7 M7
Note:
(1) For non standard coil voltage (including F7) prices please consult customer care.
(2) It is recommended to check availability with Customer Care team.
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation
accessories, ,andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 105
TeSys H - Ultra Compact Hybrid Motor Starters
22.5 mm
Up to 75 %
of space reduction
• Ultra-compact 22.5 mm starter
PB114721_R
Long electrical
durability
• Suitable for high demanding
application
Easy Easy
Design to integrate
• Wide range setting motor • Direct mounting installation
protection on DIN rail
It is recommended to check with Customer care team for selection, recommendation ,and availability of stockable and non stockable references
se.com/in 106
TeSys Protection Range
TeSys has the most rugged and reliable solution to manage motors
Please find a quick range overview below
GV2ME GV4PEM LRD LR9F LR9G EOCR TeSys Ultra TeSys T TeSys Island
Short circuit
Causes of overheating
Slight overload
Locked rotor
Abnormal temperature
With Probes
rise
Voltage variation
(Derived)
Causes of phase
variation
Phase reversal
Phase losses
Phase imbalance
se.com/in 107
Protection Relays for
Motor Safety
se.com/in/TeSys
se.com/in 108
TeSys Protect
TeSys K, TeSys Deca, TeSys F, TeSys Giga
Thermal Overload Relays - Tesys K Series Electronic Overload Relay - TeSys Deca Series
(Direct Mounting)
• Conformance to IEC, UL, CSA, CE • Conformance to IEC, UL, CSA
• Range : 0.1A to 16A • Range : 0.1A to 32A
• Direct & Independent mounting • 5:1 Adjustment range
• Trip class 10A
• High Operating Temperature
• Field selectable tripping class : 5,10, 20 & 30
• Type 1 & Type 2 Co-ordination chart available
Thermal Protection For Use Unit MRP Unit MRP
For Use With Current Range For Use With Reference*
Adjustment With [`] [`]
0.11...0.16 LR2K0301 0.1....0.5 LR9D01 10680
0.16...0.23 LR2K0302 0.4....2.0 LC1D09 - 38A Direct LR9D02
10965
0.23...0.36 LR2K0303 1.6....8.0 Mounting LR9D08
0.36...0.54 LR2K0304 6.4....32 LR9D32 12265
0.54...0.8 LR2K0305
*Note: For LR9D01 to LR9D32 - Terminal Block for Clip on Mounting
0.8...1.2 LR2K0306 LAD7B205.
2340
1.2...1.8 LC1K, LP1K, LP4K, LR2K0307
1.8...2.6 LP2K, LC2K LR2K0308
2.6...3.7 LR2K0310 Electronic Overload Relay - TeSys F Series
3.7...5.5 LR2K0312
5.5...8 LR2K0314 • Conformity to International Standards - IEC,
8...11.5 LR2K0316 UL, CSA
10...14 LR2K0321 • Direct mounting on contactors is possible
12...16 LR2K0322 2380 upto 630A
*Note: Terminal Block for Clip-on Mounting LA7K0064 • Higher operating temperature
• Tripping class 10
Thermal Overload Relays - TeSys Deca Series
Unit MRP
• Conformance to IEC, UL, CSA Thermal Protection Adjustment Range Reference*
[`]
• Range : 0.1A to 104A LRD Model (Direct Mounting)
• Higher operating temperature 90...150 LR9F5369
• Tripping class 10A & 20 available
132...220 LR9F5371
• Direct mounting on contactor is possible
200...330 LR9F7375 On Request
upto 95A
300...500 LR9F7379
380...630 LR9F7381
Thermal Protection Unit MRP
For Use With Reference*
Adjustment Range [`]
NEW
LRD Model (Direct Mounting) Electronic Overload Relay - TeSys Giga Series
0.1...0.16 LRD01
0.16...0.25 LRD02 • Wide range of protection with only 4
0.25...0.4 LRD03 references (28A to 630A)
0.4...0.63 LRD04 • Switchable protection against ground fault
0.63...1 LRD05 and phase imbalance
2350
1...1.6 LRD06
GV2L03, LE03, • ON status and overload alarm signaling by
1.6...2.5 LRD07
LC1D09...LC1D38 LED
2.5...4 LRD08
4...6 LRD10 • Direct mouting of relay with contactors
5.5...8 LRD12
saving in panel space and installation time
7...10 LRD14 • Selectable Trip class from 5E to class 30E to
2640
9...13 LRD16 suit different application needs
12...18 LRD21
GV2L22, 2720 Unit MRP
16...24 LRD22 Thermal Protection Adjustment Range Reference
LC1D25...D38 [`]
LC1D25...LC1D38, 28…115 A LR9G115 18000
23...32 LRD32
LC1D32 4370 57…225 A LR9G225 21000
30...38 LC1D32, LC1D38 LRD35
125…500 A LR9G500 24700
LC1D40A...D65a LRD332
23...32 160…630 A LR9G630* on request
LC1D80...LC1D95 LRD3353
30...40 LC1D40A...D65a LRD340
4840 *To be launched in Q2 2022
30...40 LC1D80...LC1D95 LRD3355
*Note:
LC1D40A...D65a LRD350 6635
37...50 • For LRD01...LRD35 - Terminal Block for clip-on Mounting LAD7B106
LC1D80...LC1D95 LRD3357 7935
• For LRD33** - Terminal Block for clip-on Mounting LA7D3064
48...65 LC1D40A...D65a LRD365 8515
• For LRD332, LRD340, LRD350 & LRD365 - Connection block for separate
62…80 LC1D80A LRD380 8880 mounting LAD96560
48...65 LC1D80...LC1D95 LRD3359 8515 • The LRD relays can be used for AC or DC current up to 104A
63...80 LC1D80...LC1D95 LRD3363 9240 • For long starting, Class 20 relays are available on request.
80...104 LC1D80, LC1D95 LRD3365 11405 • Device for remote tripping and electrical reset is available on request.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 109
Advanced
Motor Protection
High performance protection
for your application
EOLR EOCR
Electronic Overload Relay Electronic Over Current Relay
• Precise Overload Protection • Compact and Robust
• Wide operating Range 5:1 • Advanced current protections
• Higher Operating Temperature • Suitable for 1-phase and 3-phase applications
• Selectable Trip Class • Suitable for motors upto 400A
• Pass-through CT for electrical isolation
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMALse.com/in/TeSys
STOCK ITEMS W.E.F. January 25, 2022
se.com/in 110
TeSys Protect
EOLR, EOCR
EOLR Protection Relay Selection Table
Note: For LR9D01 to LR9D32 - Terminal Block for Clip on Mounting * - over current based protection Possible solution
LAD7B205.
# - with SSD Ideal solution
$ - upto 38 Amps
Analog EOCR
• Compact
• Protection against over current/phase loss/locked rotor (phase
loss/locked rotor operates by over current)
• Manual (instant)/electrical reset
• NVR (No Volt Release) function / Fail Safe
• Suitable for single-phase / 3-phase motors
• LED (operation display and active current display)
5 0.5-6A For 60A or higher, combine 05 Type 5 0.5-6A For 60A or higher, combine 05Type
Current Current
1 30 3.0-30A and an external CT (secondary 5A) 1 30 3.0-30A and an external CT (secondary 5A)
Setting Range Setting Range
60 5.0-60A for use 60 5.0-60A for use
Note: For a CT combination type, please write an accessory code from the Note: For a CT combination type, please write an accessory code from the
CT Order Codes separately. CT Order Codes separately.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 111
TeSys Protect
EOCR
• Micro-controller unit based
NEW
• Real time processing / High precision
Digital EOCR • Protections : Over current, Under current, Phase loss, Phase
reversal, Stall, Jam, Current Imbalance, Earth fault (3MZ2/
FMZ2/3BZ2/FBZ2)
• Current Rating - 0.5 to 400A
• Bar graph indication of a load current to the current setting.
• Ancillary functions : Fail safe, Accumulated running hour, 3 faults
records & limitation of auto-restart.
• Individual phase I-THD monitoring
• Suitable low Frequency Operation
• Communication capable RS485 (Optional)
EOCR Accessories
ZCT - Ground Fault Protection ZCT - Ground Fault Protection
Unit MRP 3CT H1 100 Z
Reference Description
[`]
1
ZCT-035-Z ZCT EP 35 mm 6130
ZCT-080-Z ZCT EP 80 mm 8295 Unit MRP
Reference Description
[`]
ZCT-120-Z ZCT EP 120 mm 13650
H1-100-Z Square 3CT 100:5 4905
HH-150-Z Square 3CT 150:5 6075
Display Cable for FDM2/FMZ2/FBZ2 1 CT ratio H2-200-Z Square 3CT 200:5 6730
Unit MRP H3-300-Z Square 3CT 300:5 7050
Reference Description
[`] H4-400-Z Square 3CT 400:5 8295
CABLE-RJ45-001Q CABLE 1M 2230
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 112
TeSys Power
Circuit breakers for Motor protection
se.com/in 113
TeSys Power
Circuit Breakers for Motor Protection
Magnetic Circuit Breaker Thermal Magnetic Circuit Breaker
• Conformance to IEC 60947 -1,-2,-4 • Conformance to IEC 60947 -1,-2,-4,
• Magnetic circuit breakers range from conformity to International Standards
- UL, CSA, CE
0.1-80 Amps
• Thermal magnetic circuit breakers range
• High Breaking capacity up to 100kA from 0.1-220 Amps
• Wide range of accessories • High Breaking capacity up to 100kA
• Wide range of accessories
• S-shaped busbar for side-by-side
connection with 40 - 65A Contactor
Thermal
Breaking Motor Power Magnetic Breaking Motor Power
AC-3** Unit MRP AC-3** Protection Unit MRP
Capacity at Protection Reference Capacity at Reference
[`] Adjustment [`]
415V 50Hz kW HP Rating (A) 415V 50Hz kW HP Range
With Rocker Lever Control (Economy)* With Push Button Control (Economy)
0.09 - 0.4 GV2LE03 - - 0.1 - 0.16 GV2ME01
0.18 - 0.63 GV2LE04 0.06 - 0.16 - 0.25 GV2ME02 5235
0.37 0.5 1 GV2LE05 0.09 - 0.25 - 0.40 GV2ME03
0.55 - 1.6 GV2LE06 0.18 - 0.40 - 0.63 GV2ME04
100kA 5565
1.1 1.5 2.5 GV2LE07 4875 0.37 0.5 0.63 - 1.0 GV2ME05
100kA
1.5 2 4 GV2LE08 0.55 0.75 1.0 - 1.6 GV2ME06
5690
2.2 3 6.3 GV2LE10 0.75 1 1.6 - 2.5 GV2ME07
3 5.5 10 GV2LE14 1.1 2 2.5 - 4 GV2ME08
5.5 7.5 14 GV2LE16 2.2 3 4 - 6.3 GV2ME10 5885
15kA 7.5 10 18 GV2LE20 3 5.5 6 - 10 GV2ME14
5660
11 15 25 GV2LE22 5.5 7.5 9 - 14 GV2ME16 6600
10kA 15 20 32 GV2LE32 9615 7.5 10 13 - 18 GV2ME20 7100
15kA(1)
With Rotary Handle Control* 9 12.5 17 - 23 GV2ME21 7580
0.09 - 0.4 GV2L03 11 15 20 - 25 GV2ME22 7580
0.18 - 0.63 GV2L04 10kA(1) 15 20 24 - 32 GV2ME32 12280
0.37 0.5 1 GV2L05 With Rotary Handle Control
0.55 - 1.6 GV2L06 - - 0.1 - 0.16 GV2P01
100kA
1.1 1.5 2.5 GV2L07 0.06 - 0.16 - 0.25 GV2P02 5095
1.1 2 4 GV2L08 0.09 - 0.25 - 0.40 GV2P03
5595
2.2 3 6.3 GV2L10 0.18 - 0.40 - 0.63 GV2P04
4 5.5 10 GV2L14 0.37 0.5 0.63 - 1.0 GV2P05
5840
5.5 7.5 14 GV2L16 100kA 0.55 0.75 1.0 - 1.6 GV2P06
7.5 10 18 GV2L20 0.75 1 1.6 - 2.5 GV2P07
11 15 25 GV2L22 1.1 2 2.5 - 4 GV2P08
6020
15 20 32 GV2L32 2.2 3 4 - 6.3 GV2P10
50kA
18.5 25 40 GV3L40 15775 3 5.5 6 - 10 GV2P14 6420
22 29 50 GV3L50 16145 5.5 7.5 9 - 14 GV2P16 7885
30 40 65 GV3L65 16495 7.5 10 13 - 18 GV2P20
37 50 73 GV3L73 18650 50kA(2) 9 12.5 17 - 23 GV2P21 9105
With Toggle Control 11 15 20 - 25 GV2P22
37 50 80 GV4LE80N6 35kA(2) 15 20 24 - 32 GV2P32 15340
15525
55 74 115 GV4LE115N6 18.5 30...40 GV3P40 17925
75 101 150 LV430832 22 37...50 GV3P50 22225
50kA 50kA
110 147 220 LV431752 30 48...65 GV3P65 22795
On Request
160 214 320 LV432749 37 62…73 GV3P73 23300
200 268 500 LV432949 With Toggle Control
* Conforming to IEC 60947-2-3-4 37 49.58 40…80 GV4PE80N6
50kA 20125
** 50/60Hz - 415V 55 73.7 65…115 GV4PE115N6
• GV2-L with the TeSys Deca contactor and LRD overload relay provides
Type 2 Co-ordination
With Direct Rotary Handle
75 101 70…150 GV5P150H 42085
** 50/60Hz - 415V 110 147 100...220 GV5P220H 49095
70kA
(1) With GV1-L3 current limiter, breaking capacity can be increased to 100kA. 160 214 160...320 GV6P320H 63125
Combination of the GV2-M with the TeSys Deca provides Type 2 Co-
ordination. 200 268 250...500 GV6P500H 86970
(2) With GV1-L3 current limiter, breaking capacity can be increased to 100kA.
Combination of the GV2-P with the TeSys Deca providesType 2 Co-ordination.
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation,
accessories, andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 114
TeSys Power
Circuit Breakers for Motor Protection
GV4LE
• IEC/EN 60947-1, IEC/EN 60947-2, CCC, EAC
• Can be used with class 5, 10 or 20 relay
• Short Circuit Protection with an adjustable pick-up Ii = 6 to 14 In.
• From 0.25 - 55kW
Note: For Everlink termination please order after removing the 6 at the end Eg. GV4LE115N
GV4PE
• IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60497-4-1,
CCC, EAC, CSA
• Overload or thermal protection
• Short time delay protection
• Short circuit protection
• Fixed Ground fault protection
• Phase unbalance or phase loss
• Front indications through LED
• Variable Trip class : Trip Class 10/ Trip Class 20
Note: For Everlink version please order after removing the 6 at the end. Eg. GV4PE115N
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation,
accessories, andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 115
TeSys Power
Circuit Breakers for Motor Protection
Accessories for GV4
MX Shunt Trip
• Trips the circuit breaker when the control voltage rises above 70% of rated
voltage
• Shunt trip 110..130V AC is suitable.. etc for ground fault protection when
combined with a Class I ground fault sensing element
Unit MRP
Description Mounting Voltage References
[`]
220-240 VAC 50 Hz, 208-240 VAC 60 Hz,
Mx Shunt Trip Internal, Plug-In GV4AS287 3465
277 VAC 60 Hz
Mn Under Voltage Release Internal, Plug-In 440-480 VAC 60 Hz GV4AU486 5125
Unit MRP
Description Maximum Number Mounting Type of Contacts Reference
[`]
Auxiliary Contact Block 2 (1 Each For OF or SD) Internal Plug-In NO + NC GV4AE11 1220
Rotary Handles
Unit MRP
Description Type Degree of Protection Reference
[`]
Direct Mounting Rotary Handle BLACK IP40 GV4ADN01 1815
BLACK IP54 GV4APN01
RED HANDLE ON 2695
Front Extended Rotary Handle (Min Shaft Length 214Mm/Max IP54 GV4APN02
YELLOW BEZEL
Shaft Length 627Mm)
RED HANDLE ON
IP65 GV4APN04 2835
YELLOW BEZEL
Connection Accessories
Description Reference
Spreader 3-pole (To increase pitch to 35mm) (1 pce) LV426940
It
Foris Itdetails
recommended
is recommendedto check
to check
on non standard withwith
Customer
Customer
references, carecare
team
technical team
for selection,
for selection,
parameters, recommendation,
recommendation
accessories, and,and
compatibility, availability
availability
stockable of non
and stockable
of stockable
andand
stockable nonnon
stockable
status stockable
please references
references
contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 116
TeSys Power
Circuit Breakers for Motor Protection
Accessories for Motor Circuit Breakers Accessories for Motor Circuit Breakers
Unit MRP Unit MRP
Description Reference Description Reference
[`] [`]
For GV2 For GV2-P/GV2-L
Front contact NO or NC(1) GVAE1 1070 External operator - IP54, Black GV2APN01 3780
GVAE11 1315 External operator - IP54, Yellow/Red GV2APN02 6965
Front contact NO + NC
GVAE20 1450 Visible isolation block - for motor circuit
GV2AK00 3165
breaker GV2
GVAN11
Side contact NO + NC 1585 For GV3P/GV3L
GVAN20
Auxiliary Contacts
Fault signalling contact + 1NO contact (2) GVAD1010
2065 Front contact: 1 NO (fault) + 1NC (Auxiliary) GVAED011 1365
Fault signalling contact + 1NC contact (2) GVAD1001
Front contact: 1 NO (fault) + 1NO (Auxiliary) GVAED101 1500
Short circuit signalling contact block 1 C/O GVAM11 1970
Busbar
Under 110 ... 115V 50Hz GVAU115 4175
3-pole, 3 tap, 64 mm pitch GV3G364 1790
voltage 220 ... 240V 50Hz GVAU225
S-shape bus bar GV3S 1340
trip 380 ... 400V 50Hz GVAU385
External Operator
110 ... 115V 50Hz GVAS115 3770
IP54, Black GV3APN01 4515
Shunt trip 220 ... 240V 50Hz GVAS225
IP54, Yellow/Red GV3APN02 4330
380 ... 400V 50Hz GVAS385
Note: All other accessories are same as of GV2.
Additive limiter for increasing breaking
GV1L3 6085 Busbars GV3G364 and GV3S are not compatible with GV3*73 and GV3*80.
capacity to100kA for GV2ME and GV2P.
Connection block - GV2 with contactor
GV2AF3 740
LC1-D09..D38
Operating Unit MRP
Connection block - LS1 D32 or GV2 with Description Reference
Contactor LC1-K or LP1-K
GV2AF01 800 Voltage [`]
GV2MP02 3165 For GV5 and GV6
Empty enclosure for GV2ME - plastic Auxiliary contact - 1 OC - GV7AE11 2840
GV2MC02 3475
Clip-on connector - upto
(1) Choice of NC or NO contact operation depending on which way round - GV7AC021 1170
150 A - 1.5..95 mm2
the reversible block is mounted. Clip-on connector- upto
(2) The GV-AD is always mounted next to the circuit breaker. - GV7AC022 1245
220 A - 1.5..185 mm2
Front rotary handle GV7AP03 4880
GV7AP GV7R - black -
handle (2) GV7AP01 8490
Busbars Padlocking device - 1..3
No. of Unit MRP padlocks Ø 5..8mm - GV7V01 1155
Connection Pitch Reference shank(3)
Tapoff Points [`]
Terminal shields IP405(1) - GV7AC01 3020
For GV2
45 mm
2 GV2G245 1865 For GV5 and GV6
4 GV2G445 2935 200...240 V AC
Shunt release GV7AS207 6450
2 GV2G254 1885 50/60 Hz
200...240 V AC
3 GV2G354 2120 Under Voltage release GV7AU207 6660
54 mm 50/60 Hz
4 GV2G454 2655
(1) Terminal shields cannot be used together with spreaders.
5 GV2G554 2875 (2) For mounting direct rotary handle on enclosure door.
72 mm 4 GV2G472 3250 This accessory makes it possible to open the door If the device is closed and
prevents the device from being closed if the door is open.
(3) For Circuit breaker not fitted with a rotary handle
Unit MRP
Description Reference
[`]
Accessories for Busbars
Terminal block - to supply one or more
GV2G05 4075
3-pole busbar GV2
Protective end covers for unused busbar
GV1G10 720
outlets
Terminal block for connection from top GV1G09 2130
It
Foris details
recommended to check references,
on non standard with Customer care team
technical for selection,
parameters, recommendation,
accessories, andstockable
compatibility, availability of non
and stockable and status
stockable non stockable references
please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 117
TeSys
Accessories compatibility
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 118
TeSys
Accessories compatibility
GV3 G264
GV3 G364
GV AM11
GV3 P
GV AM11
GV3 L
GV AE11, GV AE20,
GV AED 101, GV AED 011
GV AE1
GV AE1
GV3 APN02
GV2 V03
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 119
TeSys GV4 Overview
k
in
rl
ve
E
m
m
link
0
2
1
GV4G Ever
eredLin k logy
6
Event techno
Pat
5
7
8
ON
SDx
JAM
T UNB
1
TAM LS
Txxs GF
T95%
SDTAM
8 10
6 12
4 14
2 15
1 OFF
2
T JAMUNB
TAM LS
SDx
Txxs GF
T95%
9
MX
250V
~/=
10 25A
S li=17
CLAS L3
SD
>95%
>XXA
ALARM
20 L2
READY
t
4 6
Ir(A)2
8 L1
1 i
10
Ii
Ir Isd
14
15
12 MN
250V
OF
10 TeSys
11
5
9659
link LAD
Ever
With
d)
(Rigi
9
mm² Cu
5S ..70
EM11
1 x 1,5.....95 Cu
1 x 1,5...
GV4P 8kV d)
Uimp
(Rigi
mm² Cu
..70
1 x 1,5.....95 Cu
Ui 800V
5A 1 x 1,5... e
In:11 g torqu
Ics(k
A) enin
A) er tight
Pow
11
Icu(k 120 N.m
) 120 100
Ue(V 5
40 100 70
220/2 mm² 9
15 70 30
380/4
O
30 18 y10
440 18 2.5 u16
500 10
525 40°C
90
690/6 Cat A
Hz
50/60 60947-2
N
IEC/E
s
TeSy 5S
EM11
t
GV4P
se
Re
Cat.A
50/60Hz
100
65
240V 14
480V
600Y/347
.8
Ø 4..
CB
LISTED
No:186
Issue
E10027
s GB14048.
TeSy 5S
Trip
EM11
15
t
GV4P
se
Re
Cat.A
50/60Hz
100
ref.
65
240V 14
Axial
480V
600Y/347
4...8
Ø 4..
.8
CB
Ø
LISTED
No:186
Issue
E10027
2
GB14048.
Trip
s
TeSy 5S
EM11
GV4P
OFF
Cat.A
50/60Hz
100
65
240V 14
480V
600Y/347
CB
LISTED
No:186
Issue
E10027
s
TeSy 5S
EM11
t
GV4P
se
2
Re
GB14048.
12
Cat.A
50/60Hz
100
65
240V 14
480V
600Y/347
CB
LISTED
No:186
Issue
E10027
2
GB14048.
Trip
Ø
4...8
On
ip
Tr
On
.8
Ø 4..
ip
Off
Tr
et
Res
Ø
4..
.8
14
.8
Ø 4..
Off
et
Res
13
14
13
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 120
TeSys Control
TeSys Switches
Vario Switch Disconnectors Vario Switch Disconnectors
[Ithe] Rated [Ithe] onventional Unit MRP
Conventional Poles Operational Unit MRP Poles Description Reference
Reference Thermal Current** [`]
Thermal Description Power [`] Complete Switch with Padlockable Operator
Current** (AC-23)* • Suitable for Front Mounting or Base Mounting
Complete Enclosed Switches 12 3P VCF02 2275
• Range 12 to 175A, IP 65 Sealable and Lockable
20 3P VCF01 2475
10 3P 4 kW VCF02GE 3620
25 3P VCF0 2890
16 3P 5.5 kW VCF01GE 3940
32 3P VCF1 3030
20 3P 7.5 kW VCF0GE 4790
40 3P VCF2 3750
25 3P 11 kW VCF1GE 5140
63 3P VCF3 6990
32 3P 15 kW VCF2GE 6025
80 3P VCF4 6360
50 3P 22 kW VCF3GE 9315 125 3P VCF5 14575
63 3P 30 kW VCF4GE 10895 175 3P VCF6 17670
* Rated Power at 415V Switch Bodies
** Ith in enclosure
12 V02 1480
20 V01 1710
For Switch Mounting Unit MRP 25 V0 2035
Ingress Reference
Type (Amps) Arrangement [`] 32 V1 2475
40 V2 3030
Operators (Padlockable) 63 V3 4215
12 - 40 4 Screw Fixing IP65 KCF1PZ 950 80 V4 5540
63 - 80 4 Screw Fixing IP65 KCF2PZ 1005 125 V5 11245
125 - 175 4 Screw Fixing IP40 KCF3PZ 4075 175 V6 14350
Accessories
For Use with Pole Auxiliary Unit MRP
Description Rating in A Earth Contact Reference
Switch Bodies Composition Contacts [`]
Vario Add-on Modules (1)
V02/VCF02 12 1P - - VZ02 1060
V0/1/VCF01 20 1P - - VZ01 1080
V0/VCF0 25 1P - - VZ0 1150
Main Pole Module V1/VCF1 32 1P - - VZ1 1125
V2/VCF2 40 1P - - VZ2 1205
V3/VCF3 63 1P - - VZ3
1565
V4/VCF4 80 1P - VZ4
V02 / VCF02 to V2 / VCF2 - 1N - - VZ11 1290
Neutral Pole Module(2) V3 / VCF3 to V4 / VCF4 - 1N - - VZ12 1730
V5 / VCZ5 to V6 / VCZ6 - 1N - - VZ13 3570
V02 / VCF02 to V2 / VCF20 - - - - VZ14 1275
Earthing Module V3 / VCF3 to V4 / VCF4 - - 1 - VZ15 1505
V5 / VCZ5 to V6 / VCZ6 - - 1 - VZ16 2335
Auxiliary Contact V02/ VCF02 to V6 / VCZ6 - - - 1NO + 1NC VZ7 1330
Block Module V2/ VCF02 to V6 / VCZ6 - - - 2NO VZ20 1330
(1) For mounting option of modules, please refer to the technical catalogue.
(2) With early make and late break contacts
Unit MRP
Description For Use With Reference
[`]
Components for Door Interlocking
VZ17 1275
Shaft extension - for Mini-VARIO and VARIO - V02..V2 V02...V2
VZ30
1505
VZ18
Shaft extension - for Mini-VARIO and VARIO - V3 V4 V5 V6 V3, V4, V5, V6
VZ31 1710
VZ17 / VZ30 KZ32 405
Door interlock plate
VZ18/31 KZ74 695
Input Terminal Protection Shrouds
V02 - V2 VZ8 430
VZ26 375
V3 - V4
VZ9 455
Terminal Shrouds VZ27 375
V5 - V6
VZ10 570
VZ28 635
V02 - V6
VZ29 520
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 121
TeSys Control
Accessories for Switches
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 122
Machine builders, it is time to cut engineering
time and costs — DIGITIZE load management
TeSys island
Unique features
TeSys island is a smart, digital multifunctional load management system; it can switch,
protect, manage motors and other electrical loads up to 80 Amps (AC3) in
an electrical control panel.
Benefits
Why should you choose TeSys island?
• Quicker engineering and reduce time to market
• Embedded algorithms detect abnormal load behaviors and generate alarms before
machine stoppage.
• Pre-trip warnings can also be set on the system for scheduled maintenance.
• Fast device replacement on any portion of the island is possible because of the full
integration of the system and the integrated Bus coupler resulting in reduced downtime.
• TeSys island provides energy monitoring at the load level
• Health status can be easily accessed, remotely or locally. This energy management For more information
data can be used for advanced analytics to increase machine efficiency further on TeSys island
• TeSys island can be easily integrated into Schneider Electric’s EcoStruxure Machine Digital Load
architecture and 3rd party automation systems, supporting all major field buses. Management System
se.com/in/TeSys
se.com/in 123
TeSys Active
TeSys island
Enable smarter design and engineering
Efficient Enable new business
Make your machines intelligent, save time and models
costs with intuitive programming and commis-
sioning using TeSys avatars. Simplify software Use load data and status information to create
integration within all major automation environ- new service enabled business models. Access
ments. One-click mounting on DIN rail and no your machine from remote during operation &
need for control wiring. maintenance.
Technical specifications
• System consists of DOL Starters & Input / • Only 21 commercial references for the
Output modules complete system, including 5 standard
• System manages motors and other electri- motor starters and 5 functional safety motor
cal loads up to 80A/37kW/50hp starters
• Up to 20 modules / 1 meter at one bus • Cybersecurity embedded into the system
coupler (Achilles Level 2 & Safety up to Cat 2)
• No mechanical adjustments/settings re- • Safety stop TUV certified (Stop 0 and 1 with
quired wiring categories 1 to 2, suitable for PL c,d
(Performance Level) and SIL level 2)
• International standards-compliant
• Open connectivity thanks to Ethernet IP and
• Energy monitoring at the load level
Modbus TCP fieldbuses
se.com/in 124
TeSys Active
TeSys island
TeSys island is an innovative digital load management solution-providing data
for higher machine efficiency and ease of servicing, and allowing faster time to
market.
TeSys island is a modular, multifunctional system providing integrated functions inside an automation
architecture, primarily for the direct control and management of low-voltage loads.
After commissioning, TeSys island can switch, help protect, and manage motors and other electrical
loads up to 37 kW installed in an electrical control panel.
This system is designed around the concept of TeSys avatars. These avatars:
• Are the functional object representing a logical function of the physical module with pre-defined
logic
• Determine the configuration of the island.
The logical aspects of the island are managed with software tools, covering all phases of product and
application lifecycle: design, engineering, commissioning, operation, and maintenance.
1 6 8
2 3 4 5
7
se.com/in 125
TeSys Control
Ultra motor starters
Introduction
PB121671_R.eps
Motor circuit
breaker:
GV2L Magnetic protection
> short-circuit protection
PB121681.eps
Contactor:
LC1D Control
> Start /Stop
Status monitoring
> signaling
> alarm monitoring
PB121670_R.eps
Protection
relay:
LRD Thermal protection
> overload
DB414490.eps
se.com/in 126
TeSys Control
Ultra motor starters
Introduction
Ultra motor
starters
can be used in
80 %
DB414490.eps
of motor protection
and control
applications.
se.com/in 127
TeSys Control
Ultra motor starters
Total Coordinated Starter – 3 functions in a single device
Compact Starter, DOL / RDOL upto 18.5kW (38A, AC-3)
in 45mm width
Direct connectivity to Modbus / Profibus / CANopen /
DeviceNet
Higher switching life - 15Million operations, 2Million AC-43
electrical life
Breaking capacity upto 130kA
Control Unit
Performs all the electrical protection functions
to cover main applications
40%
from 0 to 38A.
Some of these also provide advanced meas-
urement, alarm and
display functions. “TeSys solutions allow us to reduce
the size of our enclosure”
says a panel builder from the water treatment
sector
4 simple function modules
Thermal overload alarm Indication of motor load
Thermal overload signalling and manual reset
Thermal overloaded signalling and automatic or
remote reset.
60%
“Late customization means that we
can build 60% of the panels, even
though the project design has not
Power Base 4 communication modules yet been completed”
For assembling components, Profibus DP says an engineer in a food processing
ON/OFF operation and resetting. CANopen industry
> 3 power bases: DeviceNet
upto 12A and upto 38A Modbus.
> Direct starter and
reversing starter models.
Quick Selection
Select 1 + Select 1 Optional or Optional or Optional
Communication Auxiliary
Base Power Unit Control Unit Function Module Accessories
Module* Contacts
Non-Reversing Contactor auxiliary contacts
LUB 120 LUC B X6 BL LULC 033 LUF DH11 LUFN 11
se.com/in 128
Wherever productivity
is a concern, intelligence
to Motor Control is the
solution
se.com/in 129
Tesys T Motor
Management Systems
TeSys T covers all load monitoring and protection needs from feeders to critical process automation. The equipment
is protected, while advanced diagnostics, statistics, and alarms help in anticipating unexpected production halts
and minimize downtime. TeSys T is compact and a natural fit for control panels with IEC or NEMA standards. In
addition, the system’s connectivity and access to real-time data provides key information to enhance the operation
and safety of the process while improving efficiency.
Tesys T Controller:
Intelligent motor controller for 1P/3P Motors with built in CT up to 100Amps with accurate monitoring and protection functions,
6DI, 4DO, 1CBCT input, 1 Temperature probe
Temperature monitoring via probes Motor temperature, ground current RDOL, Star-delta, two-speed starters
Phase reversal Active and Reactive Energy
Quick Selection
TeSys T Controller TeSys T Accessories
1
Required for Voltage & Power measurement
2
0.4 - 8 A 08 4 digital inputs
1.35 - 27 A 27
CAN Open C 3
Sold in lots of 6 3.0 LTM9CU30
Network Protocol
DeviceNet D
Ethernet IP /
E
Modbus TCP/IP
Modbus M
Ground Fault CT’s Current Transformers4
Profibus DP P
Primary Internal Ø Reference Primary [A] Secondary [A] Reference
[A] “d” [mm]
100 1 LT6 CT1001
65 30 50437
Voltage
Control
Note: For prices please contact regional sales office or customer care centre
se.com/in 130
TeSys Control
Enclosed switch-disconnectors and Motor Starters
• Exhaustive Range of industrial starters consisting of DOL, Reversing, Automatic star delta starters upto 400HP
• Better aesthetic & Assured performance
• Test to trip facility
• Built in single phasing protection
*Please contact local sales office for availability, recommendation and selection
se.com/in 131
Type 2 Co-ordination chart with TeSys range
Type 2 co-ordination chart for Direct-On-Line starter with circuit breaker and overload
protection built into the circuit breaker
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
(1) The breaking performance of circuit-breakers GV2 P can be increased by adding a current limiter GV1 L3
(2) Reference to be completed by replacing the * with the breaking performance code as per table given below:
GV4PE/ GV4PE/
Circuit breaker type GV5P150* GV5P220* GV5P320* GV6P500*
PEM80* PEM115*
Breaking performance Iq (kA) at 400/415V 70 70 70 70 50 50
Breaking performance code H H H H N N
For advanced protection, protection with Electronic Overcurrent Relays, heavy starting, please contact our sales teams.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 132
Type 2 Co-ordination chart
Type 2 co-ordination chart for Direct-On-Line starter with circuit breaker and separate thermal
overload relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
(1) Reference to be completed by replacing the * with the breaking performance code as per table given below:
NSX160*MA, NSX400*
Circuit breaker type NSX100*MA GV4L/LE80* GV4L/LE115*
NSX250*MA NSX630*
Breaking performance Iq (kA) at 400/415V 50 50 50 50 50
Breaking performance code N N N N N
For advanced protection, protection with Electronic Overcurrent Relays, heavy starting, please contact our sales teams.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 133
Type 2 Co-ordination chart
Type 2 co-ordination chart for Star Delta starters with circuit-breaker and separate thermal
overload relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
16 132 230 132.8 NSX400*Mic 1.3M(1) LC1G150 LC1D80 LR9G225 57 ... 225
18 200 350 202.1 NSX630*Mic 1.3M(1) LC1G225 LC1G150 LR9G225 57 ... 225
19 220 388 224 NSX630*Mic 1.3M(1) LC1G265 LC1G150 LR9G500 125 ... 500
20 250 430 248.3 NSX630*Mic 1.3M(1) LC1G265 LC1G150 LR9G500 125 ... 500
(1) Reference to be completed by replacing the * with the breaking performance code as per table given below:
NSX160*MA, NSX400*
Circuit breaker type NSX100*MA GV4L/LE80* GV4L/LE115*
NSX250*MA NSX630*
Breaking performance Iq (kA) at 400/415V 50 50 50 50 50
Breaking performance code N N N N N
For advanced protection, protection with Electronic Overcurrent Relays, heavy starting, please contact our sales teams.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 134
Type 2 Co-ordination chart
Type 2 co-ordination chart for Star Delta starter with circuit breaker and overload protection
built into circuit breaker
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
(1) Reference to be completed by replacing the * with the breaking performance code as per table given below:
GV4PE/ GV4PE/
Circuit breaker type GV5P150* GV5P220* GV5P320* GV6P500*
PEM80* PEM115*
Breaking performance Iq (kA) at 400/415V 70 70 70 70 50 50
Breaking performance code H H H H N N
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 135
Type 2 Co-ordination chart
Type 2 Co-ordination chart for Direct-On-Line starter with circuit breaker and separate thermal
overload relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
Sr.
3F Motor power in kW Circuit Breaker Contactor Thermal Overload Relay
No.
* - Reference to be completed by replacing the * with the breaking performance code as per table given below:
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 136
Type 2 Co-ordination chart
Type 2 Co-ordination chart for Star Delta starter with circuit breaker and separate thermal
overload relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
Sr. Main/Delta
P (kW) Ie (A) Ie/1,73 (A) Circuit Breaker Star Contactor Thermal Overload Relay
No. Contactor
* - Reference to be completed by replacing the * with the breaking performance code as per table given below:
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 137
Type 2 Co-ordination chart with TeSys range
(With TeSys G Contactors and Relays) NEW
Type 2 co-ordination chart for Direct-On-Line starter with circuit breaker and overload
protection built into the circuit breaker
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
45 to 250 kW at 400/415V: type 2 coordination (with ref. GV4, GV5, GV6 circuit breakers)
Standard power ratings of 3-phase motors Circuit breaker Contactor
50/60 Hz in category AC-3e
Sr.
400/415V Ir Setting Irm
No. Reference(1) Reference
P Ie Iq (max)
kW A kA A A
1 45 80 100 GV4P/GV4PE/GV4PEM115● 86 1118 LC1G115
(1) Reference to be completed by replacing the ● with the breaking performance code:
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 138
Type 2 Co-ordination chart with TeSys range
(With TeSys G Contactors and Relays) NEW
Type 2 co-ordination chart for Direct-On-Line starter with circuit breaker and separate relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
45 to 335 kW at 400/415V: type 2 coordination (with ref GV4, or NSX circuit breakers)
Standard power ratings of 3-phase
Circuit breaker Contactor Contactor
motors 50/60 Hz in category AC-3e
Sr.
400/415V
No. Reference(1) Irm Reference Reference Ir Setting
P Ie Iq (max)
kW A kA A A
1 45 80 100 GV4L/GV4LE115p 1265 LC1G115 LR9G115 80
2 55 97 100 GV4L/GV4LE115p 1100 LC1G115 LR9G225 80
3 45 80 130 NSX100p + MA 1265 LC1G115 LR9G115 97
4 55 97 130 NSX160p + MA 1500 LC1G115 LR9G225 97
5 75 132 130 NSX160p + MA 1800 LC1G150 LR9G225 132
6 90 160 130 NSX250p + MA 2640 LC1G185 LR9G225 160
7 110 195 130 NSX250p + MA 2640 LC1G225 LR9G225 195
8 110 195 130 NSX400p + Micrologic 1.3M 3520 LC1G265 LR9G500 195
9 132 230 130 NSX400p + Micrologic 1.3M 3520 LC1G265 LR9G500 230
10 160 280 130 NSX400p + Micrologic 1.3M 3840 LC1G330 LR9G500 280
11 200 350 130 NSX630p + Micrologic 1.3M 5500 LC1G400 LR9G500 350
12 220 380 130 NSX630p + Micrologic 1.3M 5500 LC1G500 LR9G500 380
13 250 430 130 NSX630p + Micrologic 1.3M 6000 LC1G500 LR9G500 430
14 300 460 130 NS800p + Micrologic 5 8800 LC1G630 LR9G630 460
15 335 575 130 NS800p + Micrologic 5 9600 LC1G630 LR9G630 575
(1) Reference to be completed by replacing the ● with the breaking performance code:
se.com/in 139
Type 2 Co-ordination chart with TeSys range
(With TeSys G Contactors and Relays) NEW
Type 2 co-ordination chart for Star Delta starter with circuit breaker and overload protection
built into circuit breaker
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
se.com/in 140
Type 2 Co-ordination chart with TeSys range
(With TeSys G Contactors and Relays) NEW
Type 2 Co-ordination chart for Direct-On-Line starter with circuit breaker and separate thermal
overload relay
Reliable
switching for
IE2/IE3/IE4
motors IE2 IE3 IE4
kW A kA A A
1 90 160 130 NSX250● + MA 1980 LC1G115 LC1D65 LR9G115 92
3 110 195 130 NSX400● + Micrologic 1.3M 1920 LC1G150 LC1D80 LR9G225 113
4 132 230 130 NSX400● + Micrologic 1.3M 1920 LC1G150 LC1D80 LR9G225 133
5 160 280 130 NSX400● + Micrologic 1.3M 2560 LC1G185 LC1G115 LR9G225 162
6 200 350 130 NSX630● + Micrologic 1.3M 3000 LC1G225 LC1G150 LR9G225 202
7 220 380 130 NSX630● + Micrologic 1.3M 3500 LC1G265 LC1G150 LR9G500 219
8 250 430 130 NSX630● + Micrologic 1.3M 3500 LC1G265 LC1G150 LR9G500 248
9 300 460 130 NS800● + Micrologic 5 4000 LC1G330 LC1G185 LR9G500 266
10 335 575 130 NS800● + Micrologic 5 4800 LC1G400 LC1G225 LR9G500 332
11 355 610 130 NS800● + Micrologic 5 5600 LC1G400 LC1G225 LR9G500 352
12 400 627 130 NS800● + Micrologic 5 5600 LC1G400 LC1G225 LR9G500 362
13 450 695 130 NS800● + Micrologic 5 6400 LC1G500 LC1G265 LR9G500 401
(1) Reference to be completed by replacing the ● with the breaking performance code:
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 141
TeSys Giga series - Device selection
Coordination tables
Star-Delta motor starter - Common circuit diagrams
DB438528.eps
1/L1
3/L2
5/L3
DB438527.eps
1/L1
3/L2
5/L3
L1 2/T1
L2 4/T2
L3 6/T3
2/T1
4/T2
6/T3
5
1
5
1
3
5
1
3
5
1
KM2K M3
KM2
6
2
4
3
3
5
5
1
KM3 KM1
W1
U1
V1
6
2
6
W1
U1
V1
W2
U2
V2
W2
U2
V2
15 RE 18 21 22
KM1
KM3
F RE
95 96 Stop Start 15 16 21 22 A1 A2
KM3
13 KM2 14
A1 A2
RE
Overload relay
13 KM2 14 Timer
13 KM1 14 A1 A2
KM2
Recommended timing relay (RE): Zelio Time ref. RE17RMMW (12...240 V AC/DC 50/60 Hz – 8 A AC/DC contacts)
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 142
Type 2 Recommended Selection Charts for
Motor Feeder with EasyPact
Notes:
Selection is for Normal Starting time (Relay Trip classes 10A/10) applications.
Overload relay type LRE and EOCR both can be used. However, while using EOCR, setting of Trip class in
EOCR should be up to 10/10A only.
For high Inertia loads like Blowers, Pumps & ID/FD fans etc., if taking longer starting time, kindly consult us to
derive the selection. However, this selection can still be used if these applications accept relay trip class
10A/10.
Service factor of the motors considered is 1
Selection is directly valid for Switching & Protection of Motors which comply to IS: 12615 efficiency class and
can also be used for other non-standard motors whose starting current is less than or equal to starting
currents as described in IS: 12615
The rated motor current used for derivation is Full Load Current (FLC) for 3-phase, 4 Pole Squirrel Cage
Induction Motors as indicated in IS: 12615. Selection can also be used for 2 Pole, 6 Pole and 8 Pole Motors
based on rated motor current.
Higher ratings of Contactors can be used in place of recommended combinations.
These charts are derived basis Type-2 Methodology described in IEC 60947-4, Clause B.4.5.
For Star-Delta Motor feeders, In-side delta wiring is considered.
For Star Delta Motor feeders, proper Change-over time and Pause time must be ensured. Selected
combination of Motor feeders components in this chart are valid only and only when used along with timer
MSMI06 and equivalent timer from Schneider.
This selection is valid only for suggested Product combinations. Change in any of the recommended
combination including timer will invalidate the recommendations and Human safety, Installation safety and
product safety requirements may not be fulfilled.
In case of motor feeders with Circuit breaker, ensure proper Instantaneous setting as suggested in respective
charts, if any.
Max. Operating rate per Hour for contactors & Circuit breaker for Motor protection shall not be exceeded.
Product evolution and improvement is a Continuous process at Schneider Electric. Hence, recommendations
and guidelines are subject to change. Contact Schneider Electric for latest guidelines.
Contact our nearest sales office for application specific Custom / optimised selection for your motor feeders having motors with
service factor more than 1, longer starting time applications, Closed transition star delta starters, other than 400/415V perational
voltages, starting currents / inrush currents lower than specified in IS 12615
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 143
Selection Chart
Direct-on-Line starters with circuit-breaker and overload protection built into the circuit-breaker
Type GZ1E
Reliable
switching for
IE2/IE3 motors IE2 IE3
13 3 4 6 50 LC1E18 GZ1E14 6 - 10
* 50kA With current Limiter type GV1L3, 10kA without current limiter
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 144
Selection Chart
Direct-On-Line starters with circuit-breaker GZL1LE and separate thermal overload relay
Reliable
switching for
IE2/IE3 motors IE2 IE3
Thermal Overload
Sr. No. P (kW) Ie (A) Circuit Breaker Contactor Range (A)
relay
Star Delta starters with circuit-breaker GZL1LE and separate thermal overload relay
Type-2 Recommended Selection
Sr. Main/Delta
P (kW) Ie (A) Ie/1,73 (A) Circuit Breaker Star Contactor Thermal Overload Relay
No. Contactor
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 145
Selection Chart
Direct-on-Line starters with Fuses and overload protection by separate overload relay type LRE
(thermal) or EOCR** (up to Trip class 10/10A)
Reliable
switching for
IE2 motors IE2
* Relay can match with contactor electrically (i.e Cannot be directly mounted), rest all relays are suitable for direct mounting as per catalogue.
** Selection valid upto Trip class 10/10A, Contact nearest sales office for details of EOCR to be used with this selection charts.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 146
Selection Chart
Star Delta starters with Fuses and overload protection by separate overload relay type LRE
(thermal) or EOCR** (up to Trip class 10/10A)
Reliable
switching for
IE2 motors IE2
1 0.75 1 2.2 1.3 LC1E09 LC1E09 LC1E09 LRE06 1-1.6 4NHG000B 4 000 NX032 50 MSMI06
2 1.1 1.5 2.9 1.7 LC1E09 LC1E09 LC1E09 LRE07 1.6-2.5 4NHG000B 4 000 NX032 50 MSMI06
3 1.3 1.75 3 1.7 LC1E09 LC1E09 LC1E09 LRE07 1.6-2.5 4NHG000B 4 000 NX032 50 MSMI06
4 1.5 2 3.8 2.2 LC1E09 LC1E09 LC1E09 LRE07 1.6-2.5 6NHG000B 6 000 NX032 50 MSMI06
5 2.2 3 5.1 2.9 LC1E09 LC1E09 LC1E09 LRE08 2.5-4 10NHG000B 10 000 NX032 50 MSMI06
6 3 4 6 3.5 LC1E09 LC1E09 LC1E09 LRE08 2.5-4 10NHG000B 10 000 NX032 50 MSMI06
7 3.7 5 8.1 4.7 LC1E09 LC1E09 LC1E09 LRE10 4-6 10NHG000B 10 000 NX032 50 MSMI06
8 4 5.5 8.5 4.9 LC1E09 LC1E09 LC1E09 LRE10 4-6 16NHG000B 16 000 NX032 50 MSMI06
9 5.5 7.5 11.4 6.6 LC1E09 LC1E09 LC1E09 LRE12 5.5-8 16NHG000B 16 000 NX032 50 MSMI06
10 7.5 10 15.4 8.9 LC1E09 LC1E09 LC1E09 LRE14 7-10 20NHG000B 20 000 NX032 50 MSMI06
11 9.3 12.5 17.3 10.0 LC1E12 LC1E12 LC1E09 LRE14 7-10 20NHG000B 20 000 NX032 50 MSMI06
12 11 15 22 12.7 LC1E18 LC1E18 LC1E09 LRE16 9-13 32NHG000B 32 000 NX032 50 MSMI06
13 15 20 30 17.3 LC1E18 LC1E18 LC1E09 LRE21 12-18 40NHG000B 40 000 NX063 50 MSMI06
14 18.5 25 36 20.8 LC1E25 LC1E25 LC1E09 LRE22 16-24 40NHG000B 40 000 NX063 50 MSMI06
15 22 30 43 24.8 LC1E25 LC1E25 LC1E25 LRE32 23-32 50NHG000B 50 000 NX063 50 MSMI06
16 30 40 56 32.3 LC1E40 LC1E40 LC1E25 LRE355 30-40 63NHG000B 63 000 NX063 50 MSMI06
17 37 50 69 39.8 LC1E50 LC1E50 LC1E32 LRE355 30-40 80NHG000B 80 000 NX080 50 MSMI06
18 45 60 84 48.5 LC1E50 LC1E50 LC1E32 LRE357 37-50 100NHG00B 100 00 NX125 50 MSMI06
19 55 75 99 57.2 LC1E65 LC1E65 LC1E40 LRE359 48-65 125NHG00B 125 00 NX125 50 MSMI06
20 75 100 134 77.4 LC1E80 LC1E80 LC1E65 LRE363 63-80 160NHG00B 160 00 NX160 50 MSMI06
21 80 110 139 80.3 LC1E80 LC1E80 LC1E80 LRE363 63-80 160NHG00B 160 00 NX160 50 MSMI06
22 90 120 164 94.7 LC1E95 LC1E95 LC1E80 LRE365 80-104 200NHG1B 200 1 NX200 50 MSMI06
23 110 150 204 117.8 LC1E120 LC1E120 LC1E95 LRE482 84-135 250NHG1B 250 1 NX250 50 MSMI06
24 125 170 234 135.1 LC1E160 LC1E160 LC1E120 LRE483* 124-198 250NHG1B 250 1 NX250 50 MSMI06
25 132 180 247 142.6 LC1E160 LC1E160 LC1E120 LRE483* 124-198 250NHG1B 250 1 NX250 50 MSMI06
26 150 200 248 143.2 LC1E160 LC1E160 LC1E120 LRE483* 124-198 250NHG1B 250 1 NX250 50 MSMI06
27 160 215 288 166.3 LC1E200 LC1E200 LC1E160 LRE483 124-198 315NHG2B 300 2 NX315 50 MSMI06
28 180 240 298 172.1 LC1E200 LC1E200 LC1E160 LRE483 124-198 315NHG2B 300 2 NX315 50 MSMI06
29 200 270 348 200.9 LC1E250 LC1E250 LC1E160 LRE484 146-234 400NHG2B 400 2 NX400 50 MSMI06
30 225 300 360 207.9 LC1E250 LC1E250 LC1E160 LRE484 146-234 400NHG2B 400 2 NX400 50 MSMI06
31 250 335 435 251.2 LC1E300 LC1E300 LC1E200 LRE485 174-279 450NHG3B 450 3 NX630 50 MSMI06
32 275 370 440 254.0 LC1E300 LC1E300 LC1E200 LRE485 174-279 450NHG3B 450 3 NX630 50 MSMI06
33 315 425 548 316.4 LC1E400 LC1E400 LC1E250 LRE486 208-333 630NHG3B 630 3 NX630 50 MSMI06
34 335 452 580 334.9 LC1E400 LC1E400 LC1E250 LRE487 258-414 630NHG3B 630 3 NX630 50 MSMI06
35 355 475 618 356.8 LC1E400 LC1E400 LC1E250 LRE487 258-414 630NHG3B 630 3 NX630 50 MSMI06
36 375 502 653 377.0 LC1E400 LC1E400 LC1E250 LRE487 258-414 800NHG3B 800 3 NA 50 MSMI06
37 400 535 674 389.1 LC1E500 LC1E500 LC1E300 LRE487 258-414 800NHG3B 800 3 NA 200 MSMI06
* Relay can match with contactor electrically (i.e Cannot be directly mounted), rest all relays are suitable for direct mounting as per catalogue.
Use alternate suggested for direct mounting.
** Selection valid upto Trip class 10/10A, Contact nearest sales office for details of EOCR to be used with this selection charts.
# For guaranteed performance, Motor feeders built using this chart must make use of MSMI06 or equivalent Schneider Electric make timer only.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 147
Selection Chart
Direct-on-Line starters with circuit-breaker type CVS and overload protection by separate
overload relay type LRE (thermal) or EOCR** (up to Trip class 10/10A)
Reliable
switching for
IE2/IE3 motors IE2 IE3
* Relay can match with contactor electrically (i.e Cannot be directly mounted), rest all relays are suitable for direct mounting as per catalogue.
Use alternate suggested for direct mounting.
** Selection valid upto Trip class 10/10A, Contact nearest sales office for details of EOCR to be used with this selection charts.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 148
Selection Chart
Star Delta starters with circuit-breaker type CVS and overload protection by separate overload
relay type LRE (thermal) or EOCR** (up to Trip class 10/10A)
Reliable
switching for
IE2/IE3 motors IE2 IE3
* Relay can match with contactor electrically (i.e Cannot be directly mounted), rest all relays are suitable for direct mounting as per catalogue.
Use alternate suggested for direct mounting.
** Selection valid upto Trip class 10/10A, Contact nearest sales office for details of EOCR to be used with this selection charts.
# For guaranteed performance, Motor feeders built using this chart must make use of MSMI06 or equivalent Schneider Electric make timer only.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 149
Phaseo Power Supplies
Panel Mount_Easyline
Unit MRP
Input Voltage Output Voltage Output Current Reference Description
[`]
100...240 V AC single phase 24V 1.5A ABL2REM24015K ABL2_K Power Supply, DC24V output, 35W 2376
100...240 V AC single phase 24V 2A ABL2REM24020K ABL2_K Power Supply, DC24V output, 50W 2634
100...240 V AC single phase 24V 4.5A ABL2REM24045K ABL2_K Power Supply, DC24V output, 100W 3901
100...240 V AC single phase 24V 6.5A ABL2REM24065K ABL2_K Power Supply, DC24V output, 150W 4707
100...240 V AC single phase 24V 8.5A ABL2REM24085K ABL2_K Power Supply, DC24V output, 200W 6242
100...240 V AC single phase 24V 10A ABL2REM24100K ABL2_K Power Supply, DC24V output, 250W 7140
100...240 V AC single phase 24V 15A ABL2REM24150K ABL2_K Power Supply, DC24V output, 350W 11642
Unit MRP
Input Voltage Output Voltage Output Current Reference Description
[`]
100...240 V AC single phase 12V 8.5A ABLP1A12085 Power Supply 12V 8.5A Panel Mount, 100W 6772
100...240 V AC single phase 24V 4.5A ABLP1A24045 Power Supply 24V 4.5A Panel Mount, 100W 6208
100...240 V AC single phase 24V 6.2A ABLP1A24062 Power Supply 24V 6.2A Panel Mount, 150W 8848
100...240 V AC single phase 24V 10A ABLP1A24100 Power Supply 24V 10A Panel Mount, 240W 12189
Modular ABLM
• Mounting on panel with screw without additional part
• Up to +70°C operating
• Direct access to the documentation
• Over voltage Category III
• Compact size
Unit MRP
Input Voltage Output Voltage Output Current Reference Description
[`]
100...240 V AC single phase 5V 3.6A ABLM1A05036 Power Supply 5V 3.6A Modular, 18W 6203
100...240 V AC single phase 12V 1A ABLM1A12010 Power Supply 12V 1A Modular, 12W 4414
100...240 V AC single phase 12V 2.1A ABLM1A12021 Power Supply 12V 2.1A Modular, 25W 6203
100...240 V AC single phase 12V 4.2A ABLM1A12042 Power Supply 12V 4.2A Modular, 50W 8197
100...240 V AC single phase 24V 0.4A ABLM1A24004 Power Supply 24V 0.4A Modular, 10W 3711
100...240 V AC single phase 24V 0.6A ABLM1A24006 Power Supply 24V 0.6A Modular, 15W 4542
100...240 V AC single phase 24V 1.2A ABLM1A24012 Power Supply 24V 1.2A Modular, 30W 6203
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 150
Phaseo Power Supplies
Optimized ABLS
• 3 housings, select the best suited to the space
• Up to 6 output terminals
• Output voltage adjustment
• Direct access to the documentation
• 100-240 Vac Input
Unit MRP
Input Voltage Output Voltage Output Current Reference Description
[`]
100...240 V AC single phase 12V 6.2A ABLS1A12062 Power Supply 12V 6.2A Optimized, 75W 7878
100...240 V AC single phase 12V 10A ABLS1A12100 Power Supply 12V 10A Optimized, 120W 11851
100...240 V AC single phase 24V 2.1A ABLS1A24021 Power Supply 24V 2.1A Optimized, 50W 7350
100...240 V AC single phase 24V 3.1A ABLS1A24031 Power Supply 24V 3.1A Optimized, 75W 7562
100...240 V AC single phase 24V 3.8A ABLS1A24038 Power Supply 24V 3.8A Optimized, 91.2W 12725
100...240 V AC single phase 24V 5A ABLS1A24050 Power Supply 24V 5A Optimized, 120W 11174
100...240 V AC single phase 24V 10A ABLS1A24100 Power Supply 24V 10A Optimized, 240W 16365
100...240 V AC single phase 24V 20A ABLS1A24200 Power Supply 24V 20A Optimized, 480W 29569
100...240 V AC single phase 48V 2.5A ABLS1A48025 Power Supply 48V 2.5A Optimized,120W 11851
Universal ABL8RP/WP
• 100-500 Vac (1 or 2 Phases) Or 380-500Vac 3 Phases Input terminals
• Automatic or Manual reset
• 2 diagnosis LED (U/I)
• 4 to 10 mm2 output terminals
• Tool-free removal from omega (DIN) rail
• Protection of settings (sealable)
• Diagnosis relay
Unit MRP
Input Voltage Output Voltage Output Current Reference Description
[`]
100...120 V AC single phase,
terminal(s): N-L1
24V 3A ABL8RPS24030 Univ. Power Supply 1P 24V 3A, 72W 15039
200...500 V AC phase to
phase,terminal(s): L1-L2
100...120 V AC single phase,
terminal(s): N-L1
24V 5A ABL8RPS24050 Univ. Power Supply 1P 24V 5A, 120W 19443
200...500 V AC phase to phase,
terminal(s): L1-L2
100...120 V AC single phase,
terminal(s): N-L1
24V 10A ABL8RPS24100 Univ. Power Supply 1P 24V 10A, 240W 22212
200...500 V AC phase to phase,
terminal(s): L1-L2
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 151
Phaseo Transformers
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 152
Phaseo Transformers
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 153
Innovative & Connected Altivar Drives and Altistart Soft Starters
Variable Speed Drives
Process Fluid Management Industrial Processes
Altivar Process 600 Altivar Process 900
Mining,
Wall Mounting Wall Mounting
Minerals & Marine
0.75...315 kW 0.75...315 kW
Metals 200...690 V 200...690 V
Power
Oil & Gas Plants
Altivar 310L
Material Harsh environment IP54
Textile
Working 0.75 to 5.5 kW
380...460 V
Packaging
Simple & Advanced Machines
Altivar 320B/C Altivar 320W
Book/compact format Harsh environment
0.18...15 kW IP65/66
200...600 V 0.18...7.5 kW
380...480 V
Fans &
Compressors IP55
0.75...75 kW
380...480 V
Soft Starters
Industrial Processes & Utility Simple Machines
Altistart 48 Altistart 22 ATS480 Altistart 01
17...1200 A 17...590 A 208 to 690V 3...85 A
208...690 V 208...600 V 17 to 1700A 110...480 V
Coming
Soon
se.com/in 154
Altivar Easy 310
Drives for Simple Machines When just enough
is just right!
NEW
Now available upto 22kW
se.com/drives
se.com/in 155
Altivar Variable Frequency Drives
Altivar12 Drive: 1-Phase / 3-Phase 230 Volts Input & 3-Phase 230 Volts Output Drive
• Small: easily integrated in any machine
• Discreet & Intuitive
• Reliable: quality which stands the test of time
• High-performance: even without adjustment
Altivar310 Drive: 3-Phase 440 Volts Input & 3-Phase 440 Volts Output Drive
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 156
Automation and control
made easy
Easy Altivar 610 variable speed drives.
se.com/easyaltivar610
se.com/in 157
Easy Altivar 610
Now available upto 460V NEW
EMC:
C3 level filter embedded
Harmonics:
DC choke embedded (above 4kW)
Protection:
IP20
Display terminal
Operation temperature:
-15°C to +60°C (derating above +45°C) Basic keypad (standard)
• LCD backlight, removable
Motor control law: • 2 lines, 6 languages
Asy motor: V/f 2 pts; V/f 5 pts; • Configuration save
UF quad; energy saving • Easy mounting kit (Ø22mm)
se.com/easyaltivar610
se.com/in 158
Altivar Variable Frequency Drives
Altivar610 Drive: Drives for pumps and fans from 0.75 to 160 kW
Now available upto 460V NEW
• Compact size: simplicity of integration and reduction of the size of the enclosures
• Electronic cards with protective coating
• Operation temperature: -10…+60°C
• IP40 protection level on the top of the product
• Typical multi-pump configuration without PLC
• 7 preprogrammed function blocks cover 90% of the pump and fan applications
• Colored control circuit terminals to avoid misuse
Unit MRP
kW Max. continuous current(A) Reference
[`]
Three phase-Supply Voltage: 380…480V
0.75 2.2 ATV212H075N4 On Request
1.5 3.7 ATV212HU15N4 On Request
2.2 5.1 ATV212HU22N4 On Request
3 7.2 ATV212HU30N4 On Request
4 9.1 ATV212HU40N4 On Request
5.5 12 ATV212HU55N4 On Request
7.5 16 ATV212HU75N4 On Request
11 22.5 ATV212HD11N4 On Request
15 30.5 ATV212HD15N4 On Request
18.5 37 ATV212HD18N4 On Request
22 43.5 ATV212HD22N4 On Request
30 58.5 ATV212HD30N4 On Request
37 79 ATV212HD37N4 On Request
45 94 ATV212HD45N4 On Request
55 116 ATV212HD55N4 On Request
75 160 ATV212HD75N4 On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 159
Altivar Variable Frequency Drives
Machine Drives
Unit MRP
kW Max. continuous current(A) Reference
[`]
Single phase-Supply Voltage: 200…240V
0.18 1.5 ATV320U02M2C On Request
0.37 3.3 ATV320U04M2C On Request
0.55 3.7 ATV320U06M2C On Request
0.75 4.8 ATV320U07M2C On Request
1.1 6.9 ATV320U11M2C On Request
1.5 8 ATV320U15M2C On Request
2.2 11 ATV320U22M2C On Request
Three phase-Supply Voltage: 200…240V
1.5 8 ATV320U15M3C On Request
4 17.5 ATV320U40M3C On Request
5.5 27.5 ATV320U55M3C On Request
7.5 33 ATV320U75M3C On Request
11 54 ATV320D11M3C On Request
15 66 ATV320D15M3C On Request
Three phase-Supply Voltage: 380…500V (COMPACT)
0.37 1.5 ATV320U04N4C On Request
0.55 1.9 ATV320U06N4C On Request
0.75 2.3 ATV320U07N4C On Request
1.1 3 ATV320U11N4C On Request
1.5 4.1 ATV320U15N4C On Request
2.2 5.5 ATV320U22N4C On Request
3 7.1 ATV320U30N4C On Request
4 9.5 ATV320U40N4C On Request
5.5 14.3 ATV320U55N4C On Request
7.5 17 ATV320U75N4C On Request
11 27.7 ATV320D11N4C On Request
15 33 ATV320D15N4C On Request
Three phase-Supply Voltage: 380…500V (BOOK)
0.4 1.5 ATV320U04N4B On Request
0.6 1.9 ATV320U06N4B On Request
0.8 2.3 ATV320U07N4B On Request
1.1 3 ATV320U11N4B On Request
1.5 4.1 ATV320U15N4B On Request
2.2 5.5 ATV320U22N4B On Request
3 7.1 ATV320U30N4B On Request
4 9.5 ATV320U40N4B On Request
5.5 14.3 ATV320U55N4B On Request
7.5 17 ATV320U75N4B On Request
11 27.7 ATV320D11N4B On Request
15 33 ATV320D15N4B On Request
Three phase-Supply Voltage: 380…500V, IP66
0.37 1.5 ATV320U04N4W* On Request
0.55 1.9 ATV320U06N4W* On Request
0.75 2.3 ATV320U07N4W* On Request
1.1 3 ATV320U11N4W* On Request
1.5 4.1 ATV320U15N4W* On Request
2.2 5.5 ATV320U22N4W* On Request
3 7.1 ATV320U30N4W* On Request
4 9.5 ATV320U40N4W* On Request
5.5 14.3 ATV320U55N4W* On Request
7.5 17 ATV320U75N4W* On Request
Note: References ending with B are BOOK type & Reference ending with C are COMPACT type.
References ending with N4W* are IP66.
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 160
Altivar
The next SMART manufacturing era
Altivar Machine ATV340, innovative
variable speed drives for high-performance machines
The Altivar™ Machine ATV340* drive is robust for high overloads, offering
safety, various communication protocols, and cutting-edge motor control
solution for machine builders.
* From 1 HP to 100 HP in heavy duty with 3-phase supply voltage from 380
to 480 V.
Please contact Customer care center for Stockable and Non stockable status of references.
se.com/drives
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 161
High performance in material handling,
material working and hoisting
The ATV340 improves the capabilities and availability of high-performance
machines while reducing build costs thanks to: 220%
Nominal torque
• Superior machine performance. With a maximum torque availability of 1.8
ln and optimized speed bandwidth of up to 400 Hz, the ATV 340 is ideal
for dynamic applications with rapid acceleration. Its frequency inverters
can handle high overloads in demanding applications up to 220% nominal
torque.
1 ms
Application cycle time
Please contact Customer care center for Stockable and Non stockable status of references.
se.com/drives
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 162
Altivar Variable Frequency Drives
ATV340 Modular Drive: Power & Supply Voltage: 0.75 – 22 kW & 400/480 V three phase
ATV340 Ethernet Drive(ATV340***N4E): Power & Supply Voltage: 0.75 – 75 kW & 400/480 V three phase
kW Max. continuous current (A) Unit MRP
Reference
ND HD ND HD [`]
Three phase-Supply Voltage: 380…480V (Modular)
1.1 0.75 2.8 2.2 ATV340U07N4 On Request
2.2 1.5 5.6 4 ATV340U15N4 On Request
3 2.2 7.2 5.6 ATV340U22N4 On Request
4 3 9.3 7.2 ATV340U30N4 On Request
5.5 4 12.7 9.3 ATV340U40N4 On Request
7.5 5.5 16.5 12.7 ATV340U55N4 On Request
11 7.5 24 16.5 ATV340U75N4 On Request
15 11 32 24 ATV340D11N4 On Request
18.5 15 39 32 ATV340D15N4 On Request
22 18.5 46 39 ATV340D18N4 On Request
30 22 62 46 ATV340D22N4 On Request
Three phase-Supply Voltage: 380…480V (With Ethernet)
1.1 0.75 2.8 2.2 ATV340U07N4E On Request
2.2 1.5 5.6 4 ATV340U15N4E On Request
3 2.2 7.2 5.6 ATV340U22N4E On Request
4 3 9.3 7.2 ATV340U30N4E On Request
5.5 4 12.7 9.3 ATV340U40N4E On Request
8 5.5 16.5 12.7 ATV340U55N4E On Request
11 8 24 16.5 ATV340U75N4E On Request
15 11 32 24 ATV340D11N4E On Request
18.5 15 39 32 ATV340D15N4E On Request
22 18.5 46 39 ATV340D18N4E On Request
30 22 62 46 ATV340D22N4E On Request
37 30 74.5 61.5 ATV340D30N4E On Request
45 37 88 74.5 ATV340D37N4E On Request
55 45 106 88 ATV340D45N4E On Request
75 55 145 106 ATV340D55N4E On Request
90 75 173 145 ATV340D75N4E On Request
*ATV340 display is optional - VW3A1113
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 163
Altivar Process Drives for industrial utility
applications
Altivar process drives deliver added-value services to enable business and process optimization
through improved life cycle asset management and optimized energy consumption. Designed to assist
OEMs, system integrators, and industrial process owners, Altivar process drives improve process
performance by enabling full information and operational technology convergence.
Embedded PlantStruxureTM and FoxboroTM Evo architectures simplify systemintegration.
Water applications Oil & Gas applications Mining & Metals applications
se.com/in 164
Altivar Variable Frequency Drives
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 165
Altivar Variable Frequency Drives
Altivar Process ATV930: Variable speed drives dedicated to constant torque application
with excellent motor control and connectivity capabilities (0.75kW to 315kW)
se.com/in 166
Reduce mechanical stress
on your machines
Altistart 01
Altistart 22
Altistart 48
se.com/drives
se.com/in 167
Altistart range: soft starters designed for your
machines
Small and simple Altistart 01 - small footprint and high soft start value
All-in-one device Altistart 22 - compact soft start/soft stop unit with integrated by-pass
• Designed for 3-phase AC motors and harsh applications (starting time >30s)
• Patented torque control system (TCS) to manage soft start and dynamic
breaking
• Motor thermal protection and motor preheating function
• Machine under- and overload protection
• Cascaded starting and deceleration of a number of motors
• Integrated modbus communication and other gateway solutions
• Type 2 coordination
• Large number of configurable I/O
• Automatic restart
• Plug-and-play factory setting
se.com/in 168
Altistart Soft Starter
Soft Starter
[Us] Rated Supply Network Number [Ie] Rated Operational Unit MRP
Motor Power kW Starting Time Reference
Voltage of Phases Current (A) [`]
1.5kW/2.2kW/3kW adjustable from 1 to 10s 6 ATS01N206QN On Request
4kW adjustable from 1 to 10s 9 ATS01N209QN On Request
380….415V
3 5.5kW adjustable from 1 to 10s 12 ATS01N212QN On Request
50…..60Hz
7.5kW/11kW adjustable from 1 to 10s 22 ATS01N222QN On Request
15kW adjustable from 1 to 10s 32 ATS01N232QN On Request
ATS22 Soft Starter: Soft Starter for Utilities i.e. Pump & fan
Unit MRP
kW (400 V) Nominal Current (Amps) Reference
[`]
Three phase-Supply Voltage: 230V…440V
7.5 17 ATS22D17Q On Request
15 32 ATS22D32Q On Request
22 47 ATS22D47Q On Request
30 62 ATS22D62Q On Request
37 75 ATS22D75Q On Request
45 88 ATS22D88Q On Request
55 110 ATS22C11Q On Request
75 140 ATS22C14Q On Request
90 170 ATS22C17Q On Request
110 210 ATS22C21Q On Request
132 250 ATS22C25Q On Request
160 320 ATS22C32Q On Request
220 410 ATS22C41Q On Request
250 480 ATS22C48Q On Request
315 590 ATS22C59Q On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 169
Altistart Soft Starter
Altistart 48 offers you the benefits of its patented Torque Control System (TCS). Ready for immediate start-up, with simplified
wiring and extended communication functions, it can be integrated at the heart of your applications in complete simplicity
For STD Application For Severe Application For STD Application For Severe Application Unit MRP
Reference
kW (400V) kW (400V) Nominal Current (Amps) Nominal Current (Amps) [`]
Three phase-Supply Voltage: 230V…415V
7.5 5.5 17 12 ATS48D17Q On Request
11 7.5 22 17 ATS48D22Q On Request
15 11 32 22 ATS48D32Q On Request
19 15 38 32 ATS48D38Q On Request
22 18.5 47 38 ATS48D47Q On Request
30 22 62 47 ATS48D62Q On Request
37 30 75 62 ATS48D75Q On Request
45 37 88 75 ATS48D88Q On Request
55 45 110 88 ATS48C11Q On Request
75 55 140 110 ATS48C14Q On Request
90 75 170 140 ATS48C17Q On Request
110 90 210 170 ATS48C21Q On Request
132 110 250 210 ATS48C25Q On Request
160 132 320 250 ATS48C32Q On Request
220 160 410 320 ATS48C41Q On Request
250 220 480 410 ATS48C48Q On Request
315 250 590 480 ATS48C59Q On Request
355 315 660 590 ATS48C66Q On Request
400 355 790 660 ATS48C79Q On Request
500 400 1000 790 ATS48M10Q On Request
630 500 1200 1000 ATS48M12Q On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 170
Zelio Plug - In Relays
Unit MRP
Product description Reference
[`]
1CO 10A Relay +LTB-LED 48VAC RXG11E7 695
1CO 10A Relay +LTB-LED 120VAC RXG11F7 735
1CO 10A Relay +LTB-LED 220VAC RXG11M7 708
1CO 10A Relay +LTB-LED 230VAC RXG11P7 694
1CO 10A Relay +LTB-LED 6VDC RXG11RD 561
1CO 10A Relay +LTB-LED 12VDC RXG11JD 561
1CO 10A Relay +LTB-LED 24VDC RXG11BD 558
1CO 10A Relay +LTB-LED 48VDC RXG11ED 561
1CO 10A Relay +LTB-LED 60VDC RXG11ND 561
1CO 10A Relay +LTB-LED 110VDC RXG11FD 561
1CO 10A Relay +LTB+LED 24VAC RXG12B7 755
1CO 10A Relay +LTB+LED 48VAC RXG12E7 755
1CO 10A Relay +LTB+LED 120VAC RXG12F7 755
1CO 10A Relay +LTB+LED 220VAC RXG12M7 755
1CO 10A Relay +LTB+LED 230VAC RXG12P7 755
1CO 10A Relay +LTB+LED 6VDC RXG12RD 617
1CO 10A Relay +LTB+LED 12VDC RXG12JD 617
1CO 10A Relay +LTB+LED 24VDC RXG12BD 629
1CO 10A Relay +LTB+LED 60VDC RXG12ND 617
1CO 10A Relay +LTB+LED 110VDC RXG12FD 617
1CO 10A Relay-LTB+LED 48VAC RXG13E7 726
1CO 10A Relay-LTB+LED 220VAC RXG13M7 726
1CO 10A Relay-LTB+LED 230VAC RXG13P7 739
1CO 10A Relay-LTB+LED 6VDC RXG13RD 586
1CO 10A Relay-LTB+LED 24VDC RXG13BD 586
1CO 10A Relay-LTB+LED 48VDC RXG13ED 586
1CO 10A Relay-LTB+LED 60VDC RXG13ND 586
1CO 10A Relay-LTB+LED 110VDC RXG13FD 586
1CO 10A Relay Clear 24VAC RXG15B7 629
1CO 10A Relay Clear 48VAC RXG15E7 629
1CO 10A Relay Clear 120VAC RXG15F7 629
1CO 10A Relay Clear 220VAC RXG15M7 629
1CO 10A Relay Clear 230VAC RXG15P7 629
1CO 10A Relay Clear 6VDC RXG15RD 490
1CO 10A Relay Clear 12VDC RXG15JD 517
1CO 10A Relay Clear 24VDC RXG15BD 528
1CO 10A Relay Clear 48VDC RXG15ED 490
1CO 10A Relay Clear 60VDC RXG15ND 490
1CO 10A Relay Clear 110VDC RXG15FD 490
2CO 5A Relay +LTB-LED 24VAC RXG21B7 748
2CO 5A Relay +LTB-LED 120VAC RXG21F7 762
2CO 5A Relay +LTB-LED 220VAC RXG21M7 820
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 171
Zelio Plug - In Relays
Unit MRP
Product description Reference
[`]
2CO 5A Relay +LTB-LED 230VAC RXG21P7 748
2CO 5A Relay +LTB-LED 6VDC RXG21RD 628
2CO 5A Relay +LTB-LED 12VDC RXG21JD 639
2CO 5A Relay +LTB-LED 24VDC RXG21BD 628
2CO 5A Relay +LTB-LED 48VDC RXG21ED 628
2CO 5A Relay +LTB-LED 60VDC RXG21ND 628
2CO 5A Relay +LTB-LED 110VDC RXG21FD 639
2CO 5A Relay +LTB+LED 24VAC RXG22B7 840
2CO 5A Relay +LTB+LED 48VAC RXG22E7 824
2CO 5A Relay +LTB+LED 120VAC RXG22F7 840
2CO 5A Relay +LTB+LED 220VAC RXG22M7 824
2CO 5A Relay +LTB+LED 230VAC RXG22P7 840
2CO 5A Relay +LTB+LED 6VDC RXG22RD 685
2CO 5A Relay +LTB+LED 12VDC RXG22JD 685
2CO 5A Relay +LTB+LED 24VDC RXG22BD 699
2CO 5A Relay +LTB+LED 48VDC RXG22ED 724
2CO 5A Relay +LTB+LED 60VDC RXG22ND 685
2CO 5A Relay +LTB+LED 110VDC RXG22FD 685
2CO 5A Relay-LTB+LED 24VAC RXG23B7 793
2CO 5A Relay-LTB+LED 48VAC RXG23E7 793
2CO 5A Relay-LTB+LED 120VAC RXG23F7 793
2CO 5A Relay-LTB+LED 220VAC RXG23M7 793
2CO 5A Relay-LTB+LED 230VAC RXG23P7 807
2CO 5A Relay-LTB+LED 6VDC RXG23RD 655
2CO 5A Relay-LTB+LED 12VDC RXG23JD 655
2CO 5A Relay-LTB+LED 24VDC RXG23BD 655
2CO 5A Relay-LTB+LED 48VDC RXG23ED 655
2CO 5A Relay-LTB+LED 60VDC RXG23ND 655
2CO 5A Relay-LTB+LED 110VDC RXG23FD 655
2CO 5A Relay Clear 48VAC RXG25E7 695
2CO 5A Relay Clear 220VAC RXG25M7 735
2CO 5A Relay Clear 230VAC RXG25P7 695
2CO 5A Relay Clear 6VDC RXG25RD 557
2CO 5A Relay Clear 12VDC RXG25JD 557
2CO 5A Relay Clear 24VDC RXG25BD 567
2CO 5A Relay Clear 48VDC RXG25ED 557
2CO 5A Relay Clear 60VDC RXG25ND 557
2CO 5A Relay Clear 110VDC RXG25FD 557
Accessories
1CO Separate terminal socket with clamp RGZE1S35M 352
2CO Separate terminal socket with clamp RGZE1S48M 389
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 172
Zelio Plug - In Relays
Accessories
Unit MRP
Description Reference
[`]
Sockets
Sockets - mixed-screw clamp - relay type RXM2 (without lockable test button) RXZE1M2C 212
Sockets - mixed-screw clamp - relay type RXM2/RXM4 (without lockable test button) RXZE1M4C 270
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 173
Zelio Plug - In Relays
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 174
Zelio Plug - In Relays
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 175
Zelio Plug - In Relays
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 176
Zelio Electronic Timers/Control Relays
NEW
RE17 Electronic Timers
Unit MRP
Description Reference
[`]
On Delay Timer 24 240 Vac RE17LAMW 2823
Off Delay Timer 24 240VAC RE17LCBM 3301
Timer Function H Solid State Output 24 240VAC RE17LHBM 4223
Flashing Timer RE17LLBM 3470
Multi Functiontion Timer RE17LMBM 3399
Timer Function A at 1C O 24VAC DC 240VAC RE17RAMU 2648
Timer Function B 1C O 24VAC DC 240VAC RE17RBMU 3936
Timer Function C 1C O 24VAC DC 240VAC RE17RCMU 2770
Timer Function H Ht 1C O 24VAC DC 240VAC RE17RHMU 2849
Flashing Timer RE17RLJU 3703
Timer Function L Li 1C O 24VAC DC 240VAC RE17RLMU 3703
MultiFunction Timer 1C O 24VAC DC 240VAC RE17RMEMU 3360
10 X MultiFunction Timer 1C O 12VAC DC RE17RMJU 3503
MultiFunction Timer 1C O 24VAC DC 240VAC RE17RMMU 3405
MultiFunction Timer 1C O 12 240VAC DC RE17RMMW 3792
MultiFunction Timer 1C O 12 240VAC DC RE17RMMWS 4084
MultiFunction Timer 1C O 24VAC DC 240VAC RE17RMXMU 4283
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 177
Zelio Electronic Timers/Control Relays
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 178
Harmony Control & Signalling Units
XB5/XB7 Series (Lot size 20 nos.)
Biometric Switch Pilot lights
Unit MRP Supply Unit MRP
Description Reference Description Colour Reference
[`] Voltage [`]
Bistable biometric switch, 24 V DC
XB5S1B2L2 39876
With smooth lens (except clear colour)
- PNP - by 2m cable
White XB7EV01BPN 286
Bistable biometric switch, 24 V DC Green XB7EV03BPN 265
XB5S1B2M12 42070
- PNP - by M12 connector
Red XB7EV04BPN 265
~ 24V
Monostable biometric switch, 24 V DC Yellow XB7EV05BPN 265
XB5S2B2L2 40399
- PNP - by 2m cable
Amber XB7EV08BPN 265
Monostable biometric switch, 24 V DC Blue XB7EV06BPN 544
XB5S2B2M12 41941
- PNP - by M12 connector
Green XB7EV03GPN 265
~ 120V Red XB7EV04GPN 265
Accessories Direct Integral LED
Amber XB7EV08GPN 265
Unit MRP White XB7EV01MPN 286
Description Reference
[`] Green XB7EV03MPN 265
Diameter 22 mm nut ZB5SZ71 440 Red XB7EV04MPN 265
Legend plate 28X7 mm ZBY0101T 194 ~ 230V Yellow XB7EV05MPN 265
Amber XB7EV08MPN 265
Blue XB7EV06MPN 544
Clear XB7EV07MPN* 265
Pushbuttons
Type of Unit MRP
Description Colour Reference
Contact [`]
Spring return
NO White XB5AA11N 189
NO Black XB5AA21N 177
NO Green XB5AA31N 177
NO Yellow XB5AA51N 177
Flush
NO Blue XB5AA61N 177
NC Red XB5AA42N 177
NO Red XB5AA41N 177
NO Blank XB5AA01N* 189
NO White XB5AL11N 224
NO Black XB5AL21N 216
NO Green XB5AL31N 216
Projecting NO Yellow XB5AL51N 216
NO Blue XB5AL61N 216
NC Red XB5AL42N 216
NO Red XB5AL41N 216
NO Black XB5AP21N 254
Flush with silicon NO Green XB5AP31N 271
transparent boot NO Yellow XB5AP51N 254
NO Blue XB5AP61N 260
NO Green XB5AA3311N 253
NC Red XB5AA4322N 253
Flush, marked
(double molding / NO Green XB5AA3331N 253
injection marking) NC Red XB5AA4342N 253
NC Red XB5AA4352N 368
Projecting, marked NC Red XB5AL4342N 265
(double molding /
injection marking) NC Red XB5AL4352N 265
Flush, marked ‘‘I/O’’ NO+NC Green XB5AL845N 1253
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 179
Harmony Control & Signalling Units
XB5/XB7 Series (Lot size 20 nos.)
Illuminated Pushbutton
Unit MRP
Description Type of Contact Colour Reference
[`]
With smooth lens (except clear colour)
NO White XB5AW31B1N 520
NO Green XB5AW33B1N 520
NC Red XB5AW34B2N 520
Flush Integral LED ~ 24V NO Yellow XB5AW35B1N 520
NO Amber XB5AW38B1N 581
NO Blue XB5AW36B1N 1005
NO Clear XB5AW37B1N* 1005
NO White XB5AW11B1N 510
NO Green XB5AW13B1N 520
NC Red XB5AW14B2N 520
Projecting Integral LED ~ 24V NO Yellow XB5AW15B1N 520
NO Amber XB5AW18B1N 510
NO Blue XB5AW16B1N 987
NO Clear XB5AW17B1N* 525
NO White XB5AW31G1N 633
NO Green XB5AW33G1N 633
Flush Integral LED ~ 110V
NC Red XB5AW34G2N 633
NO Clear XB5AW37G1N* 1150
NO White XB5AW31M1N 592
NO Green XB5AW33M1N 520
NC Red XB5AW34M2N 520
Flush Integral LED ~ 230V NO Yellow XB5AW35M1N 520
NO Amber XB5AW38M1N 581
NO Blue XB5AW36M1N 1005
NO Clear XB5AW37M1N* 1116
NO White XB5AW11M1N 673
NO Yellow XB5AW15M1N 735
Projecting Integral LED ~ 230V NO Amber XB5AW18M1N 721
NO Blue XB5AW16M1N 1395
NO Clear XB5AW17M1N* 525
* Clear type illuminated Push buttons are provided with striated lens.
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 180
Harmony Control & Signalling Units
XB5/XB7 Series (Lot size 20 nos.)
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 181
Harmony Control & Signalling Units
XB5/XB7 Series (Lot size 20 nos.)
Non Illuminated Selector switches & Key switches Pushbutton caps (unmarked)
• For use with ZB5-AAON circular pushbutton heads supplied without caps
Type Type of Unit MRP
Unit MRP Colour Reference
Description of Reference Pushbutton caps [`]
[`]
Contact White ZBA1N 66
2 stay put 1NO XB5AD21N 437 Black ZBA2N 46
2 spring return, Red ZBA4N 43
1NO XB5AD41N 695 Flush
right to left Yellow ZBA5N 46
Standard
Blue ZBA6N 46
handle black 3 stay put 2NO XB5AD33N 477
Set of 6 colours* ZBA9N 119
3 spring return to White ZBL1N 122
2NO XB5AD53N 507
center Black ZBL2N 122
Green ZBL3N 122
2 stay put* 1NO XB5AG21N 669 Projecting Red ZBL4N 122
Yellow ZBL5N 122
2 stay put* 1NO XB5AG41N 713 Blue ZBL6N 122
Set of 6 colors* ZBL9N 122
2 spring return,
Key switch 1NO XB5AG61N 1267
right to left
Pushbutton caps (marked)
3 stay put* 2NO XB5AG03N 567
Type of Colour
Colour Unit MRP
3 spring return, Pushbutton of Reference
2NO XB5AG083N 966 Text Colour Cap [`]
right to center caps
STOP White Red ZBL434N 189
* Please refer catalogue for Key withdrawal position
I White Green ZBA331N 189
START White Green ZBA333N 182
Projecting Flush
ON White Green ZBA341N** 188
(Double injection
STOP White Red ZBA434N 182
moulded marking)
UP Black White ZBA343N 188
DOWN White Black ZBA344N 273
OFF White Red ZBA434N 182
* Set of 6 colours white + black + green + red + yellow + blue
** Excluding ZBA-341N of double injection moulded marking
Accessories Accessories
Legend Unit MRP Unit MRP
Description Marking Reference Description Application Reference
Colour [`] [`]
With blank legend White/Yellow For Ø 22 control and
Blank ZBY4101N 177 Plastic blanking plug,
(for engraving) bkgd. signalling units with ZB5SZ3N 128
round black,
circular head
Inch ZBY2321N 186
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 182
Harmony Control & Signalling Units
XB5 / XB7 Series (Lot size 20 nos.)
Unit MRP
Description Reference
[`]
Metal flush mounting kit (PB and PL). ZB4BZ021 1140
Metal flush mounting kit (SS and IPB). ZB4BZ022 1199
Plastic flush mounting kit (PB and PL). ZB5AZ021 1000
Plastic flush mounting kit for legend 8x27 (PB and PL). ZB5AZ023 1140
Unit MRP
Description Reference
[`]
HeadØ22+mountingbase+potentiometer4K7 XB4BD912R4K7 On Request
HeadØ22+mountingbase+potentiometer4K7 XB5AD912R4K7 On Request
100…240VAC/DCPanelmountedØ22mmtimermonofunctionwith3s..60sdelay XB5DTGM3 On Request
PanelmountedUSB3port-Ø22mm-forUSBinterfacejacktypeA XB5PUSB3 On Request
PanelmountedRJ45port-Ø22mm-forEthernetconnectionXB5PRJ45 XB5PRJ45 On Request
RedemergencystopTTR40mm2NC1NOmoniXB5AS84449 XB5AS84449 On Request
RedilluestopTTR40mm2NC1NOmonit.ct XB5AS86449B4 On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 183
Signalling Control Stations & Enclosures
ZAL Bodies for LED Pilot light (for mounting on metal plate at back of enclosure)
Unit MRP
Description Colour Reference
[`]W
White ZALVB1 725
Green ZALVB3 706
~ 24V Red ZALVB4 691
Yellow ZALVB5 706
Blue ZALVB6 792
White ZALVG1 1004
Green ZALVG3 1056
~ 120V
Yellow ZALVG5 898
Blue ZALVG6 898
White ZALVM1 2233
Green ZALVM3 1270
~ 220V Red ZALVM4 1074
Yellow ZALVM5 987
Blue ZALVM6 1015
White ZBVB1 629
Green ZBVB3 484
~ 24V Red ZBVB4 484
Yellow ZBVB5 470
Blue ZBVB6 611
White ZBVG1 1403
Green ZBVG3 640
~ 120V Red ZBVG4 780
Yellow ZBVG5 743
Blue ZBVG6 1403
White ZBVM1 1436
Green ZBVM3 611
~ 220V Red ZBVM4 611
Yellow ZBVM5 610
Blue ZBVM6 732
XAL - Empty enclosures for XB5 and XB4 Push button and Pilot light
Unit MRP
Description No. of ways Color of Enclosure Reference
[`]
1 Dark grey XALD01 736
2 Dark grey XALD02 913
For normal environment 3 Dark grey XALD03 1132
Light grey base IP65 4 Dark grey XALD04 1548
5 Dark grey XALD05 2020
1 Yellow XALK01 846
For normal environment Light 2 Light Grey XALE2 610
Grey base IP54 3 Light Grey XALE3 744
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 184
Signalling Control Stations & Enclosures
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 185
Signalling Illuminated Beacons & Indicator
Banks
XVB-C Illuminated Lens Units XVB Units
Unit MRP Unit MRP
Description Light Block Colour Reference Description Reference
[`] [`]
Green XVBC33 3034 XVB Audible Signalling Unit
Red XVBC34 3093 Sound unit - continuous or intermittent
XVBC9B 9307
buzzer - 75..90 dB - 12..48 V AC DC
Lens unit - steady Orange XVBC35 3093
light - 250 V 10 W Sound unit - continuous or intermittent
Blue XVBC36 3034 XVBC9M 15645
buzzer - 75..90 dB - 120..230 V AC
Clear XVBC37 3035
XVB Base Unit + Cover
Yellow XVBC38 3034
Base unit + cover for bank XVB - without
Green XVBC4B3 8477 XVBC21 4208
flash discharge tube - black - IP 65
Lens unit - flashing Red XVBC4B4 8235 XVB Accessories
light - 24..48 V DC Orange XVBC4B5 8235 Fixing base on vertical surface - zamak
XVBC12 2550
24 V AC Blue XVBC4B6 8477 black - XVB
Yellow XVBC4B8 8089 Lateral cable entry kit with Pg 13.5 cable
XVBC14 555
gland - XVB
Green XVBC4M3 8268
Set of coloured indicator pins - 6 colors
Red XVBC4M4 8660 XVBC22 488
- XVB
Lens unit - flashing
Orange XVBC4M5 8637 Support tube + fixing base l=400 mm -
light - 48..230 V AC XVBZ03 3504
Blue XVBC4M6 8640 aluminium black - XVB
Yellow XVBC4M8 8268 Support tube + fixing base l=80 mm -
XVBZ02 2648
Green XVBC2B3 6677 aluminium black - XVB
Support tube + fixing base l=800 mm -
Red XVBC2B4 6677 XVBZ04 5216
aluminium black - XVB
Lens unit - steady Orange XVBC2B5 6677
XVB Incandescent Bulb
light - 24 V AC DC Blue XVBC2B6 8613
Clear incandescent bulb for signalling
Clear XVBC2B7 8613 DL1BLB 374
- BA 15d - 24 V 10 W
Yellow XVBC2B8 6672 Clear incandescent bulb for signalling
DL1BLG 637
Green XVBC2G3 6544 - BA 15d - 120 V 10 W
Red XVBC2G4 6549 Clear incandescent bulb for signalling
DL1BLM 406
- BA 15d - 230 V 10 W
Lens unit - steady Orange XVBC2G5 6807
light - 120 V AC Blue XVBC2G6 8251
Clear XVBC2G7 8251 XVB LED BA 15d Base Fitting
Yellow XVBC2G8 6840 [Us] Rated Signalling Unit MRP
Reference
Green XVBC2M3 6549 Supply Voltage Colour [`]
Red XVBC2M4 6549 White DL1BDB1 4996
Lens unit - steady Orange XVBC2M5 6549 Green DL1BDB3 3996
light - 230 V AC Blue XVBC2M6 9082 24 V Red DL1BDB4 3996
Clear XVBC2M7 8522 Blue DL1BDB6 4532
Yellow XVBC2M8 7129 Yellow-Orange DL1BDB8 4696
Green XVBC5B3 11765 Blue DL1BDG6 6018
Red XVBC5B4 11407 Green DL1BDG3 4770
Lens unit - flashing Orange XVBC5B5 11523 120 V AC Red DL1BDG4 4700
light - 24 V AC DC Blue XVBC5B6 14378 White DL1BDG1 6018
Clear XVBC5B7 9468 Yellow-Orange DL1BDG8 4986
Yellow XVBC5B8 11341 Blue DL1BDM6 6018
Red XVBC5G4 11749 Green DL1BDM3 5226
230 V AC
Orange XVBC5G5 11536 Red DL1BDM4 5085
Lens unit - flashing
Blue XVBC5G6 14323 White DL1BDM1 6018
light - 120 V AC
Clear XVBC5G7 13450
Yellow XVBC5G8 11707
Red XVBC5M4 11305
Lens unit - flashing Orange XVBC5M5 11749
light - 230 V AC Blue XVBC5M6 14240
Yellow XVBC5M8 11749
Flashing unit - inte-
gral LED - 230..240 Green XVBC5M3 11749
V AC
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 186
Signalling Illuminated Beacons & Indicator
Banks
Unit MRP
Description Reference
[`]
Multi-functional LED Beacon green witout buzzer DC/AC 12~24V XVR3B03 14305
Multi-functional LED Beacon red witout buzzer DC/AC 12~24V XVR3B04 14329
Multi-functional LED Beacon orange witout buzzer DC/AC 12~24V XVR3B05 14086
Multi-functional LED Beacon blue witout buzzer DC/AC 12~24V XVR3B06 14180
Multi-functional LED Beacon green witout buzzer AC 100~230V XVR3M03 14040
Multi-functional LED Beacon red witout buzzer AC 100~230V XVR3M04 13827
Multi-functional LED Beacon Orange witout buzzer AC 100~230V XVR3M05 14086
Multi-functional LED Beacon Blue witout buzzer AC 100~230V XVR3M06 14180
Multi-functional LED Beacon red with buzzer DC/AC 12~24V XVR3B04S 28192
Multi-functional LED Beacon orange with buzzer DC/AC 12~24V XVR3B05S 29022
Multi-functional LED Beacon blue with buzzer DC/AC 12~24V XVR3B06S 30258
Multi-functional LED Beacon green with buzzer AC 100~230V XVR3M03S 15578
Multi-functional LED Beacon red with buzzer AC 100~230V XVR3M04S 12926
Multi-functional LED Beacon orange with buzzer AC 100~230V XVR3M05S 13876
Multi-functional LED Beacon blue with buzzer AC 100~230V XVR3M06S 15289
Multi-functional LED Beacon orange without buzzer DC48V XVR3E05 13827
Multi-functional LED Beacon, External lens XVR3Z001 382
XVS Sirens
Unit MRP
Description Reference
[`]
2 tones siren - 106 dB - 12...24V AC/DC - white XVS10BMW
2 tones siren - 106 dB - 120V AC - white XVS10GMW 25974
2 tones siren - 106 dB - 230V AC - white XVS10MMW
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 187
Signalling Illuminated Beacons & Indicator
Banks
DL1 Incandescent Bulb
Light Unit MRP
Description Reference
Block Colour [`]
Clear incandescent bulb for signalling - ba 15d - 24 v 4 w DL1BEBS 355
Clear incandescent bulb for signalling - ba 15d - 120 v 7 w DL1BEG 375
Clear incandescent bulb for signalling - ba 15d - 230 v 5 w DL1BEMS 385
XVM Series
Tower Light with Super Bright LED and integral light diffuser
Unit MRP
Description Reference
[`]
XVMB2RASB 4120
Complete Tower 24 V AC/DC Without Buzzer XVMB2RGSB 6122
XVMB2R6AGSB 9391
XVMB2RSSB 4806
XVMB2RASSB 6580
Complete Tower 24 V AC/DC With Buzzer
XVMB2RGSSB 6938
XVMB2RAGSSB 10498
XVMG2RASB 6119
XVMG2R6AGSB 10781
XVMG2RASSB 6012
XVMG2RSSB 7772
XVMG2R6AGSSB 12897
XVMM2RASB 5699
XVMM2RGSB 6087
Complete Tower 230 V AC Without Buzzer
XVMM2RAGSB 9707
XVMM2RSSB 8439
XVMM2RASSB 8172
XVMM2RGSSB 8485
Complete Tower 230 V AC With Buzzer
XVMM2RAGSSB 10322
XVMM2R6AGSSB 13613
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 188
Signalling Illuminated Beacons & Indicator
Banks
XVM Series XVM Series
Unit MRP Unit MRP
Description Reference Description Reference
[`] [`]
Base and Cover XVMC21 871 Green Led Bulb 120 V DL2EDG3SB 1476
Tube and Base XVMC213T 1757 Blue Led Bulb 230 V DL2EDM6SB 1536
Base with Buzzer 24V XVMC29B 2503 Orange Led Bulb 230 V DL2EDM8SB 1491
Tube and Base with Buzzer 120V XVMC29G3T 3568 White Flashing Led Bulb 24 V DL2EKB1SB 1653
Base with Buzzer 230V XVMC29M 2754 Green Flashing Led Bulb 24 V DL2EKB3SB 1735
Green Lens XVMC33 968 Blue Flashing Led Bulb 24 V DL2EKB6SB 1833
Red Lens XVMC34 968 Green Flashing Led Bulb 120 V DL2EKG3SB 2823
Yellow Lens XVMC35 968 Orange Flashing Led Bulb 120 V DL2EKG8SB 2823
Blue Lens XVMC36 968 White Flashing Led Bulb 230 V DL2EKM1SB 2057
Clear Lens XVMC37 968 Green Flashing Led Bulb 230 V DL2EKM3SB 2057
100mm Aluminium Tube with Stand XVMZ02 801 Blue Flashing Led Bulb 230 V DL2EKM6SB 2097
100mm Aluminium Tube with Bracket XVMZ02T 972 Orange Flashing Led Bulb 230 V DL2EKM8SB 2097
400mm Aluminium Tube with Stand XVMZ04 1735 Strobe Bulb 120V DL6BG 3413
Cover for Replacement XVMZ081 230 Strobe Bulb 230 V DL6BM 3413
Tool for Bulb ZBZX13 243
Incandescent Bulb 24 V DL1EDBS 257
Incandescent Bulbs 120 V DL1EDGS 260
White Led Bulb 24 V DL2EDB1SB 1269
Green Led Bulb 24 V DL2EDB3SB 1269
Red Led Bulb 24 V DL2EDB4SB 1269
Blue Led Bulb 24 V DL2EDB6SB 1465
Orange Led Bulb 24 V DL2EDB8SB 1242
Voltage AC/DC 24 V B
AC 110 V G
AC 230 V M
Light source Incandescent bulb 1
(2) LED 2
Illuminated Colour Red R R R R
Orange A A A A
Green G G G G
Blue B B B B
Clear C C C C
Signalling Steady (3) (3) (3) (3)
Flashing 5 5 5 5
“Flash” 6 6 6 6
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 189
Signalling Monolithic Tower Light
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 190
Osisense Photoelectric Sensors
Optical Sensors
• XUB M18 Body
• 100mA (with overload and short circuit protection)
Unit MRP
Principle of operation Sensing Distance Output Reference
[`]
PNP NO XUB5APANM12 4175
PNP NO XUB5BPANM12 (Metal) 5533
Diffuse 0.6 m
PNP NO XUB5APANL2 4146
PNP NO XUB5BPANL2 4955
PNP NO XUB9APANM12 4398
PNP NO XUB9BPANM12 5454
Polarised reflex 2m
PNP NO XUB9APANL2 4167
PNP NO XUB9BPANL2 5454
XUB4APANL2 4019
PNP NO XUB4APANM12 4019
Fixed Diffuse 100 mm
XUB4BPANM12 (Metal) 4997
NPN NC XUB4ANBNL2 4019
XUB1APANL2 (Without
4019
Reflector)*
PNP NO XUB1APANM12 4019
Reflex
4m
XUB1BPANM12 (Metal) 4605
XUB1APBNL2 (Without
PNP NC 4019
Reflector)*
XUB2APANL2R 3562
PNP NO XUB2AKSNL2T 3565
Receiver|Thru Beam 15 m
XUB2AKSNM12T 2425
PNP NC XUB2BKSNM12T (Metal) 3106
Receiver|Thru Beam XUB2APANM12R 3562
Receiver|Thru Beam 15m PNP NO XUB2BPANM12R (Metal) 4793
Transmitter|Thru Beam XUB2AKSNL2T 3565
Note :
1. L2 stands for sensors with 2m cable
4. M12 stand for universal connectors.
Unit MRP
Principle of operation Sensing range Connection Reference
[`]
Cylindrical M18
Multi Mode > 0…20 m Cable 2 m XUB0APSNL2 7913
Multi Mode > 0…20 m Connector XUB0APSNM12 8134
Multi Mode > 0…20 m Connector XUB0BPSNM12 (Metal) 8275
Unit MRP
Principle of operation Sensing Distance Output Reference
[`]
Compact 50 x 50 mm
Reflex 7m AC/DC 1C/O Relay XUK1ARCNL2 7755
Diffuse 1m AC/DC 1C/O Relay XUK5ARCNL2 7755
Reflex polarIzed 5m AC/DC 1C/O Relay XUK9ARCNL2 7625
Multimode 30 m pnp/npn no/nc XUK0AKSAL2 10420
Multimode 30 m AC/DC 1C/O Relay XUK0ARCTL2 11965
Compact 92 x 71 mm
Diffuse 2.1 m AC/DC 1C/O relay XUX5ARCNT16 9545
Reflex Polarized 11 m AC/DC 1C/O relay XUX9ARCNT16 10561
Reflex 14 m AC/DC 1C/O relay XUX1ARCNT16 8554
Thru beam transmitter AC/DC XUX0ARCTT16T 8244
Multimode 1.3 m..40 m PNP/NPN NO/NC XUX0AKSAT16 15732
Multimode 1.3 m…40 m AC/DC 1C/O relay XUX0ARCTT16 16553
*Reflector to be ordered separately.
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 191
Osisense Photoelectric Sensors
24 x 21 XUZC24 1184
50 x 50 XUZC50 1214
80 (dia) XUZC80 1780
100 x 100 XUZC100 1723
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 192
Osisense Photoelectric Sensors
OsiSense XU
Unit MRP
SN [mm] Light Mode Output Connection Reference
[`]
Fork Sensor
30mm Red LED PNP,[NO] 2m Cable XUVR0303PANL2 7883
50mm Red LED PNP,[NO] M8 Connector XUVR0605PANM8 9616
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 193
Osisense Pressure Switches
Unit MRP
Description Pressure Range Reference
[`]
Electromechanical pressure switches for control circuit
• Suitable for air, fresh water, sea water
• Adjustable differential
• 1 C/O single pole contact
• G 1/4 (BSP female) fluid connection
• Mechanical durability - 1 x 106 operating cycles
Unit MRP
Pressure Range Output Connection Reference
[`]
0 to 10 bar 4-20mA DIN 43650 XMLP010BC21F 10711
0 to 400 bar 4-20mA DIN 43650 XMLP400BC21F 10711
0 to 400 bar 0-10V M12 XMLP400BD71F 9488
Note: 10,16, 25, 40, 60, 100, 250, 400 and 600 , bar version available in stock
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 194
Osisense Limit Switches
Unit MRP
Description Number of Poles Reference
[`]
Steel roller plunger - 1 NC + 1 NO XCKD2102G11 2070
Cat’s whisker - 1 NC + 1 NO XCKD2106G11 2330
Steel end plunger - 1 NC + 1 NO XCKD2110G11 2762
Thermoplastic roller lever - 1 NC + 1 NO XCKD2118G11 2526
Thermoplastic roller lever plunger, horizontal direction - 1 NC + 1 NO XCKD2121G11 2310
Thermoplastic adjustable roller lever - 1 NC + 1 NO XCKD2145G11 2160
Sub-assemblies Metal Bodies for XCKD
Body ZCD 1 NC + 1 NO Snap Action 2 ZCD21 2653
Body ZCD 2 NC + 1 NO Snap Action 3 ZCD39 3046
Gland and Head for ZCD Bodies
Cable gland entry Pg 11 - metal body ZCDEG11 244
Head for Limit switch - ZCE without operating lever ZCE01 683
Steel roller plunger ZCE02 904
Cat’s whisker ZCE06 1214
Steel end plunger ZCE10 720
Thermoplastic roller lever plunger, horizontal direction ZCE21 1151
Thermoplastic roller lever ZCY ZCY18* 287
Steel roller lever ZCY ZCY19* 763
Variable length thermoplastic roller lever ZCY45* 1008
*To be used with head ZCE01
Contact block for ZCD bodies
1NO + 1NC 2 XE2SP2151 738
1NO + 2NC 3 XE3SP2141 1821
Unit MRP
Description Reference
[`]
Body
Body - 1 NC + 1 NO - terminals ZCKM1 1908
Spare contacts XE2SP2151 738
For ordering complete limit switches, please select body and head listed above
Head
Head - steel roller plunger ZCKD02 975
Head - cat’s whisker ZCKD06 1071
Head - spring rod lever ZCKD08 1102
Head - steel end plunger ZCKD10 567
Delrin roller lever head ZCKD15 1177
Delrin roller lever plunger head ZCKD21 1102
Steel roller lever plunger head ZCKD23 1388
Variable length Delrin roller lever ZCKD41 1439
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 195
Osisense Limit Switches
XCK-P Thermoplastic
Conforming to IEC 947-5-1
Degree of Protection - IP 653
Double insulated
Class II conforming to IEC 536
15 million mechanical durability
1 NO+1 NC 2 pole snap action contacts with positive opening
Unit MRP
Description Reference
[`]
Steel roller plunger - 1 NC + 1 NO XCKP2102G11 1468
Cat’s whisker - 1 NC + 1 NO XCKP2106G11 2223
Steel end plunger - 1 NC + 1 NO XCKP2110G11 1220
Delrin roller lever (1) XCKP2118G11 1256
Delrin roller lever plunger, horizontal direction - 1 NC + 1 NO XCKP2121G11 1508
Delrin roller lever plunger, vertical direction - 1 NC + 1 NO XCKP2127G11 2321
Adjustable roller lever - 1 NC + 1 NO (1) (Variable Length) XCKP2145G11 1468
Spare contact block XE2SP2151 738
Note : 1 tapped entry for size 11 cable gland
(1) Adjustable through 360° in 5 steps
Unit MRP
Description Reference
[`]
Steel roller plunger XCMD2102L1 3473
Metal end plunger XCMD2110L1 2936
Thermoplastic roller lever XCMD2115L1 3035
XCK - J Metal
1NO + 1NC
Snap action
Positive opening operation
30 million operations
Heavy Duty Oil Tight to IP 667
Accuracy = 0.01 mm
Unit MRP
Description Reference
[`]
Head - without operating lever - Rotary head ZCKE05 2005
Head - cat’s whisker ZCKE06 2019
Head - spring rod lever ZCKE08 2191
Head - steel roller lever ZCKE23 3548
Head - metal end plunger ZCKE61 1717
Head - reinforced end plunger ZCKE67 2862
Body - 1 NC + 1 NO - terminals ZCKJ1 2413
Body - 2 OC - terminals 2 NO + 2 NC ZCKJ2 3910
Steel roller lever ZCKY13 519
Delrin roller lever Ø 50 mm ZCKY41 758
Nylon round rod Ø 6 mm ZCKY59 437
spare contacts XE2SP2151 738
Note:
• For ordering complete Limit Switches, please select body, head and, if necessary, roller listed above
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 196
Osisense Limit Switches
Unit MRP
Description Type of Approach Reference
[`]
Steel roller plunger - 1OC For lateral cam movement XCJ102C 1193
Steel roller plunger For transverse cam movement XCJ103C 1270
Steel end plunger Vertical cam approach XCJ110C 1069
Short flat roller lever plunger One way operation XCJ121C 1595
Short flat lever plunger XCJ125C 866
Long flat lever plunger XCJ126C 994
short roller lever plunger - flat XCJ127C 895
Long roller lever plunger - flat XCJ128C 1000
Unit MRP
Description Reference
[`]
Steel roller plunger for lateral cam movement XCE102C 1603
Steel end plunger XCE110C 1469
Thermoplastic roller lever XCE118C 1646
Variable length thermoplastic roller lever XCE145C 1989
Round rod Ø3 mm steel rod XCE154C 2872
Spring rod lever XCE181C 1911
Unit MRP
Description Type of Approach Reference
[`]
Steel roller plunger - 1 NC + 1 NO Lateral cam approach 2 directions XCKN2102G11 1029
Cat’s whisker - 1 NC + 1 NO Multi-directional approach XCKN2106G11 1229
Spring lever - 1 NC + 1 NO Multi-directional approach XCKN2108G11 1830
Steel end plunger - 1 NC + 1 NO Vertical approach 1 direction XCKN2110G11 868
Thermoplastic roller lever - 1 NC + 1 NO Lateral approach 2 directions XCKN2118G11 907
Thermoplastic roller lever plunger, horizontal direction - 1 NC + 1 NO Lateral approach 1 direction XCKN2121G11 1133
Variable length adjustable roller lever - 1 NC + 1 NO Lateral approach 2 directions XCKN2145G11 1090
Variable length adjustable Thermoplastic roller lever Ø 50 mm - 1 NC + 1 NO Lateral approach 2 directions XCKN2149G11 1339
Variable length adjustable Thermoplastic large roller lever
Lateral approach 2 directions XCKN2149P20S64 946
Ø 50 mm - 1 NC + 1 NO, snap action
Variable length adjustable Thermoplastic large roller lever
Lateral approach 2 directions XCKN2549P20S64 954
Ø 50 mm - 1 NC + 1 NO, Slow-break, break before make
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 197
Osisense Limit Switches
Unit MRP
Description Reference
[`]
Steel roller plunger for lateral cam approach XCMN2102L1 2156
Cat’s whisker - 1 NC + 1 NO XCMN2106L1 3310
Steel end plunger XCMN2110L1 1873
Thermoplastic roller lever - 1 NC + 1 NO XCMN2115L1 2068
roller lever plunger - 1 NC + 1 NO - one direction actuation XCMN2121L1 2427
Thermoplastic adjustable roller lever - 1 NC + 1 NO XCMN2145L1 2352
Unit MRP
Type of Oparator Contact Type Cable Entry Reference
[`]
With Cruciform metal rod 2x2 pole NC + NC Staggered M20 x 1.5 XCKMR54D1H29 12509
With Cruciform metal rod 2x2 pole NC + NC Staggered PG 13 Cable Gland XCKMR54D1 14171
Unit MRP
Type of Oparator Contact Type Cable Entry Reference
[`]
With cruciform metal rod 2x2 pole NC+NC staggered M20x1.5 XCKVR54D1H29 5391
Unit MRP
Type of Operator Tripping Angle Reference
[`]
Spring return roller zinc plated steel with lever 10° fault signalling 18° stopping of the
XCRT115 20925
for corrosive atmosphere conveyor belt
10° fault signalling 18° stopping of the
Spring return roller stainless steel with lever XCRT215 44922
conveyor belt
Spring Return steel roller lever 23° Stopping of the Conveyor Belt (1 C/O) XCKJ105217H29 4961
Note:
• Accuracy = 0.05 mm
• 3 cable entries tapped for CM10 cable glands
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 198
Osisense Limit Switches
XCKM.LC Metal
Unit MRP
Operation type Connection Reference
[`]
Metal end plunger Pg11 XCKM110LC 2838
Steel roller plunger PG11 XCKM102LC 2838
Steel roller lever Pg11 XCKM116LC 2044
Steel roller lever M20 XCKM116H29LC 2497
Steel roller lever Horizontal actuation Pg11 XCKM2023LC 2044
XCKJ.LC
1NO + 1NC
Snap action
10 million operations
Heavy Duty Oil Tight to IK07, IP66, IP67
Unit MRP
Operation Type Connection Reference
[`]
Metal end plunger Pg 13.5 XCKJ161LC 1962
Steel roller plunger M20 XCKJ167H29LC 2023
Steel roller plunger Pg 13.5 XCKJ167LC 2023
Steel roller lever M20 XCKJ10513H29LC 1911
Steel roller lever Pg13.5 XCKJ10513LC 1893
Var.length Thermoplastic roller lever M20 XCKJ10541H29LC 2348
Var.length Thermoplastic roller lever Pg13.5 XCKJ10541LC 2348
Polyamide 6 mm rod lever M20 XCKJ10559H29LC 2182
Var.length Steel roller lever M20 XCKJ10543H29LC 1977
Var.length Steel roller lever Pg13.5 XCKJ10543LC 1805
XCK-T Thermoplastic
Conforming to IEC 947-5-1
Degree of Protection - IP 653
Double insulated
Class II conforming to IEC 536
15 Million Mechanical durability
1 NO+1 NC 2 pole snap action contacts with positive opening
Unit MRP
Description Reference
[`]
Steel roller plunger - 1 NC + 1 NO XCKT2102G11 2035
Steel end plunger - 1 NC + 1 NO XCKT2110G11 2432
Delrin - roller lever plunger, horizontal direction - 1 NC + 1 NO XCKT2121G11 2035
Note : 2 tapped entries for size 11 cable glands
(1) Adjustable through 360° in 5 steps
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 199
Osisense Limit Switches
Unit MRP
Operation Reference
[`]
Metal end plunger XCMW110 On Request
Steel roller plunger XCMW102 On Request
Thermoplastic roller lever XCMW115 On Request
Steel roller lever XCMW116 On Request
Variable length thermoplastic roller lever XCMW145 On Request
Unit MRP
Operation Reference
[`]
Wireless transmitter for sensors and switches XZBWE112A24 On Request
Programmable receiver - 4 PNP - 200 mA - 24 V DC - 2 pusbuttons - 6 LEDs XZBWR2STT24 On Request
Unit MRP
Operation Cable Entry Reference
[`]
3 Pole NC+ NC + NO - Snap Action Pg 11 XCSPA491 3734
2 Pole NC + NO - Break Before Make, Slow Break Pg 11 XCSPA591 2833
2 Pole NC + NO - Break Before Make, Slow Break ½” NTP XCSPA592 2306
2 Pole NC + NC - Slow Break Pg 11 XCSPA791 2543
2 Pole NC + NC - Slow Break ½” NTP XCSPA792 2785
3 Pole NC+ NO + NO - Slow Break (2NO Staggered) Pg11 XCSTA591 3457
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 200
Osisense Limit Switches
Unit MRP
Body Type Contacts Voltage Locking Reference
[`]
Metal NO + NC 24V AC/DC On de-energisation XCSLF2525312 20378
Plastic NO + NC 24V AC/DC On de-energisation XCSLE2525312 15694
Plastic NC + NC + NO 24V AC/DC On de-energisation XCSLE3737312 18993
Unit MRP
Contact* Body Size Connection Reference
[`]
2-pole 1 NC + 1 NO (staggered) Compact 51 x 16 x 7 2m Cable XCSDMC5902 5476
2-pole 1 NO + 1 NO (staggered) Compact 51 x 16 x 7 2m Cable XCSDMC7902 6013
2-pole 1 NC + 1 NO (staggered) Standard 88 x 25 x 13 2m Cable XCSDMP5902 4377
2-pole 1 NO + 1 NO (staggered) Standard 88 x 25 x 13 2m Cable XCSDMP7902 4839
3-pole 1 NC + 1 NO + 1 NO (staggered) Standard 88 x 25 x 13 M12 Connector XCSDMP700L01M12 11516
3-pole 1 NC + 1 NO + 1 NO (staggered) Standard 88 x 25 x 13 M12 Connector XCSDMP701L01M12 8012
2-pole 1 NC + 1 NO (staggered) Cylindrical D=30, L= 38.5 M12 Connector XCSDMR590L01M12 7257
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 201
Osisense Inductive Sensors
Specifications: Metal/Plastic Body, Precabled, Universal M8, M12 connector, Sensing Distance: Upto 15 mm
[Sn] nominal Discrete output Discrete Unit MRP
Sensor design Reference
sensing distance function Output type [`]
Three Wire Metal 12-24V DC, Flush Mountable - Threaded
NPN XS108BLNAL2 1675
XS108BLPAL2 1384
1.5mm M8 1 NO
PNP XS108BLPAM12 1486
XS108BLPAM8 1514
Three Wire Metal 12-24V DC, Non Flush Mountable - Threaded
NPN XS208BLNAL2 1907
2.5mm M8 1 NO XS208BLPAL2 1924
PNP
XS208BLPAM12 2830
Three Wire Metal 12-24V DC, Flush Mountable - Threaded
1NC PNP XS112BLPBL2 2368
XS112BLNAL2 1272
NPN
2mm M12 XS112BLNAM12 1616
1 NO
XS112BLPAL2 1221
PNP
XS112BLPAM12 1186
Specifications : Metal/Plastic Body, Precabled, Universal M8, M12 connector, Sensing Distance: Upto 15mm
[Sn] nominal Discrete output Discrete Unit MRP
Sensor design Reference
sensing distance function Output type [`]
Two Wire - 12-240V AC Metal, Flush Mountable - Threaded
Three Wire Metal 12-24V DC, Non Flush Mountable - Threaded
NPN XS212BLNBL2 1624
1 NC
PNP XS212BLPBL2 1766
NPN XS212BLNAL2 1314
4 mm M12 NPN XS212BLNAM12 2034
1 NO PNP XS212BLPAL2 1310
PNP XS212BLPAL5 1733
PNP XS212BLPAM12 1531
Three Wire Metal 12-24V DC, Flush Mountable - Threaded
1NC PNP XS118BLPBL2 1955
XS118BLNAL2 1531
NPN
XS118BLNAM12 2065
5 mm M18
1 NO XS118BLPAL2 1376
PNP XS118BLPAL5 2758
XS118BLPAM12 1974
Three Wire Metal 12-24V DC, Non Flush Mountable - Threaded
XS218BLNAL2 1338
NPN
XS218BLNAM12 2019
8 mm M18 1 NO XS218BLPAL2 1310
PNP XS218BLPAL5 1733
XS218BLPAM12 1466
Specifications : Metal/Plastic Body, Precabled, Universal M8, M12 connector, Sensing Distance: Upto 15mm
[Sn] Nominal Discrete Discrete Unit MRP
Sensor design Reference
sensing distance Output function Output type [`]
Three Wire Metal 12-24V DC, Flush Mountable - Threaded
1NC PNP XS130BLPBL2 2634
NPN XS130BLNAL2 2554
10mm M30 1 NO XS130BLPAL2 1497
PNP
XS130BLPAM12 2616
Three Wire Metal 12-24V DC, Non Flush Mountable - Threaded
1NC PNP XS230BLPBL2 1670
NPN XS230BLNAL2 2329
XS230BLPAL2 1455
1 NO
15mm M30 PNP XS230BLPAL5 2508
XS230BLPAM12 2634
Note :
1. L2 stands for sensors with 2m cable
2. L5 stands for sensors with 5m cable
3. L10 stands for sensors with 10m cable
4. M8 & M12 stand for universal connectors.
5. Connectors to be ordered seperately.
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 202
Osisense Inductive Sensors
Accessories
Unit MRP
Description Sensor Design Reference
[`]
Fixing for cylindrical sensor m18 XSZB118 836
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 203
Osisense Inductive Sensors
Unit MRP
Sensing range Output Connection Reference
[`]
XS Cubic C2 Form
15mm 1 NO Terminal XS7C2A1PAM12 3657
20mm 1 NO + 1NC Terminal XS8C2A1PCM12 4635
40mm 1 NO + 1NC Terminal XS8C2A4PCM12 5328
XS Turret Form
15 mm 1NO + 1 NC programmable Terminals XS7C4A1DPG13 6546
15 mm 1NO + 1 NC programmable Terminals XS7C4A1MPG13 7403
20mm 1NO+ 1NC Terminals XS8C4A1PCG13 6510
20mm 1NO+ 1NC Terminals XS8C4A1PCP20 8040
20mm 1NO + 1 NC programmable Terminals XS8C4A1DPG13 15332
20mm 1NO + 1 NC programmable Terminals XS8C4A1MPG13 10405
20mm 1NO + 1 NC programmable Terminals XS8C4A1MPP20 8324
20mm 1NO + 1 NC programmable Terminals XS8C4A1MPG13 10405
XT Capacitive sensor
Unit MRP
Sensing range Output Connection Reference
[`]
8mm 1 NO 2M Cable XT218A1PAL2 4467
8mm 1NC + NO M12 Connector XT218A1PCM12 4434
15mm 1NO 2M Cable XT230A1PAL2 4880
15mm 1NO + 1 NC M12 connector XT230A1PCM12 4577
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 204
Osisense Application Sensors
OsiSense Ultasonic XX
3 wire connection
Supply voltage 10-28 V DC
Plastic case
OsiSense XX
Unit MRP
Sensing Distance Output Connection Reference
[`]
0.5m PNP [NO] M12 XX218A3PHM12 15833
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 205
Osisense Cable Accessories
Unit MRP
Connector Type Connection Shape Length Reference
[`]
Osi Sense XZ PUR cable
Industrial high end use
Nominal Current 4A
Matt Black Colour
Oparation temparature -35 .. +90OC
IP 67
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 206
Magelis Industrial PC and Display
• Our comprehensive Magelis iPC range offers industrial PCs for improved productivity
and an enhanced user experience. Choose the right industrial PC for your
environment, from our wide range and be confident that they are designed to last
Unit MRP
Product description Reference
[`]
Box PC Perf. HDD DC Win 8.1 2 slots HMIBMPHI74D2801 On Request
Box PC Perf. HDD DC Win 8.1 4 slots HMIBMPHI74D4801 On Request
Box PC Perf. SSD DC Win 7 4 slots HMIBMPSI74D470L On Request
Box PC Perf. SSD DC Win 8.1 4 slots HMIBMPSI74D4801 On Request
Box PC Univ. DC Base unit 4Gb 2 slots HMIBMU0I29D2001 On Request
Box PC Universal CFast DC WES 2 slots HMIBMUCI29D2W01 On Request
Box PC Universal HDD DC Win 8.1 2 slots HMIBMUHI29D2801 On Request
Box PC Universal HDD DC Win 8.1 4 slots HMIBMUHI29D4801 On Request
Box PC Universal SSD DC Win 8.1 2 slots HMIBMUSI29D2801 On Request
S-BOX PC Optimized CFlash DC 1 slot HMIBSOCND1E01 On Request
S-BOX PC Universal No OS DC 1 slot HMIBSU0ND1001 On Request
S-BOX PC Universal CFast DC 1 slot HMIBSUCND1W01 On Request
S-BOX PC Universal SSD DC 1 slot HMIBSUSND1W01 On Request
Box PC Universal Hard Disk DC 2 slots HMIBUHND2P01 On Request
iDisplay monitor 12" Touch DC DVI HMIDID64DTD1 On Request
iDisplay monitor 15" Touch DC DVI HMIDID73DTD1 On Request
Display PC 4:3 12'' single t. for HMIBM HMIDM6421 On Request
Display PC Wide 12'' multi-t. for HMIBM HMIDM6521 On Request
Display PC 4:3 15" single t. for HMIBM HMIDM7421 On Request
Display PC Wide 15'' multi-t. for HMIBM HMIDM7521 On Request
Display PC Wide 19'' multi-t. for HMIBM HMIDM9521 On Request
Display PC Wide 22'' multi-t. for HMIBM HMIDMA521 On Request
Enclosed PC Perf. W19 DC - Base unit HMIPEP0952D1001 On Request
Enclosed PC Perf. SSD W19 DC Win 8.1 HMIPEPS952D1801 On Request
Panel PC 12" Performance - Base unit HMIPP06D0001 On Request
Panel PC Perform. SSD 12" AC 2 slots HMIPPF6A2701 On Request
Panel PC Perform. F.Disk 15" AC 2 slots HMIPPF7A2701 On Request
Panel PC Perform. HDD 12" AC 2 slots HMIPPH6A2701 On Request
Panel PC Perform. H.Disk 15" AC 0 slot HMIPPH7A0701 On Request
Panel PC Perf 15" stainless HDD AC 2 slt HMIPRH7A2701 On Request
S-Panel PC Optimized W10 DC - Base unit HMIPSO0552D1001 On Request
S-Panel PC Optimized W15 DC - Base unit HMIPSO0752D1001 On Request
S-Panel PC Optimized CFast W15 DC WES HMIPSOC752D1W01 On Request
S-Panel PC Optimized HDD W10 DC Win 8.1 HMIPSOH552D1801 On Request
S-Panel PC Optimized HDD W15 DC Win 8.1 HMIPSOH752D1801 On Request
S-Panel PC Optimized SSD W10 DC Win 8.1 HMIPSOS552D1801 On Request
S-Panel PC Optimized SSD W15 DC Win 8.1 HMIPSOS752D1801 On Request
S-Panel PC Performance W15 DC -Base unit HMIPSP0752D1001 On Request
S-Panel PC Performance W19 DC -Base unit HMIPSP0952D1001 On Request
S-Panel PC Perf. CFast W15 DC WES HMIPSPC752D1W01 On Request
S-Panel PC Perf. CFast W19 DC WES HMIPSPC952D1W01 On Request
S-Panel PC Performance HDD W15 DC Win8.1 HMIPSPH752D1801 On Request
S-Panel PC Performance HDD W19 DC Win8.1 HMIPSPH952D1801 On Request
S-Panel PC Performance SSD W15 DC Win8.1 HMIPSPS752D1801 On Request
S-Panel PC Performance SSD W19 DC Win8.1 HMIPSPS952D1801 On Request
Panel PC Univ 15" stainless HDD DC 2 slt HMIPTH7D2P01 On Request
Panel PC 12" Universal - Base unit HMIPU06D0001 On Request
Panel PC Universal CFast 12" AC 0 slot HMIPUC6A0E01 On Request
Panel PC Universal CFast 12" DC 0 slot HMIPUC6D0E01 On Request
Panel PC Universal SSD 12" AC 0 slot HMIPUF6A0701 On Request
Panel PC Universal SSD 12" DC 0 slot HMIPUF6D0701 On Request
Panel PC Universal HDD 12" AC 0 slot HMIPUH6A0701 On Request
Panel PC Universal HDD 12" DC 0 slot HMIPUH6D0701 On Request
Panel PC Univ. H.Disk 15" DC 2 slots HMIPUH7D2P01 On Request
Panel PC Universal H.Disk 19" AC 0 slot HMIPUH9A0P01 On Request
Panel PC Universal H.Disk 19" AC 2 slots HMIPUH9A2P01 On Request
Panel PC Univ. H.Disk 19" DC 2 slots HMIPUH9D2P01 On Request
Panel PC Optimum Compact Flash 15" DC HMIPWC7D0E01 On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 207
Magelis RACK IPC
RACK IPC
Unit MRP
Product description Reference
[`]
Rack PC 2U Optimized HDD AC 3 slots HMIRSOHPA3W01 On Request
Rack PC 4U Performance SSD AC 6 slots HMIRSPFXA6701 On Request
Rack PC 4U Perf. SSD AC redund. 6 slots HMIRSPFXR6702 On Request
Rack PC 4U Performance HDD AC 6 slots HMIRSPHXA6701 On Request
Rack PC 4U Perf. HDD AC 6 slots PES HMIRSPHXA67P1 On Request
Rack PC 4U Perf. HDD AC 6 slots server HMIRSPSXR6S01 On Request
Rack PC 4U Perf. HDD AC 6 slots server HMIRSPSXR6T01 On Request
Rack PC 2U Universal HDD AC 3 slots HMIRSUH3A3701 On Request
Rack PC 2U Universal SSD AC 3 slots HMIRSUS3A3701 On Request
Vijeo XD RT, printed HMIRTWCZLSPMZZ On Request
Rack PC 2U Optim. HDD AC 3 slots No OS HMIRXOHCA3001 On Request
Rack PC 2U Optimized HDD AC 3 slots HMIRXOHCA3W01 On Request
Magelis GTU
Unit MRP
Product description Reference
[`]
7W Touch Advanced Display WVGA HMIDT351 On Request
10.4 Touch Smart Display SVGA HMIDT542 On Request
10W Touch Advanced Display WXGA HMIDT551 On Request
12.1 Touch Smart Display XGA HMIDT642 On Request
12W Touch Advanced Display WXGA HMIDT651 On Request
15 Touch Smart Display XGA HMIDT732 On Request
HMIDT732 Coated HMIDT732FC On Request
15W Touch Smart Display FWXGA HMIDT752 On Request
19W Touch Smart Display FWXGA HMIDT952 On Request
Premium BOX for Universal Panel HMIG3U On Request
HMIG3U Coated HMIG3UFC On Request
Open BOX for Universal Panel HMIG5U On Request
Open BOX for Universal Panel HMIG5U2 On Request
Magelis GTU Open BOX for Vijeo XL HMIG5UL8A On Request
Magelis SCU
Unit MRP
Product description Reference
[`]
3.5 Small Controller Panel For Machine HMISCU6A5 On Request
3.5 Small Controller Panel For Process HMISCU6B5 On Request
5.7 Small Controller Panel For Machine HMISCU8A5 On Request
5.7 Small Controller Panel For Porcess HMISCU8B5 On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 208
Magelis Basic HMI
Unit MRP
Product description Reference
[`]
5.7 Keypad Panel QVGA-TFT HMIGK2310 On Request
10.4 Keypad Panel VGA-TFT HMIGK5310 On Request
3.5 Color Touch Panel QVGA-TFT HMIGTO1300 On Request
3.5 Color Touch Panel QVGA-TFT HMIGTO1310 On Request
5.7 Color Touch Panel QVGA-TFT HMIGTO2300 On Request
5.7 Color Touch Panel QVGA-TFT HMIGTO2310 On Request
5.7 Color Touch Panel QVGA Stainless HMIGTO2315 On Request
7.0 Color Touch Panel WVGA-TFT HMIGTO3510 On Request
7.5 Color Touch Panel VGA-TFT HMIGTO4310 On Request
10.4 Color Touch Panel VGA-TFT HMIGTO5310 On Request
HMIGTO5310 coated and logo removed HMIGTO5310FCW On Request
HMIGTO5310 logo removed HMIGTO5310FW On Request
10.4 Color Touch Panel VGA Stainless HMIGTO5315 On Request
12.1 Color Touch Panel SVGA-TFT HMIGTO6310 On Request
HMIGTO6310 Coated HMIGTO6310FC On Request
12.1 Color Touch Panel SVGA Stainless HMIGTO6315 On Request
STU rear module HMIS5T On Request
STU 3in5 front module HMIS65 On Request
STU3in5 front module w/o mark on overlay HMIS65W On Request
STU 5in7 front module HMIS85 On Request
STU5in7 front module w/o mark on overlay HMIS85W On Request
REAR MODULE SMALL CONTROLLER MACHINE HMISAC On Request
REAR MODULE SMALL CONTROLLER PROCESS HMISBC On Request
TOUCH PANEL SCREEN 3"4 MONOCHROME G/O/R HMISTO511 On Request
TOUCH PANEL SCREEN 3"4 MONOCHROME W/P/R HMISTO512 On Request
Touch Panel Screen 3"4 Mono ETH G/O/R HMISTO531 On Request
Touch Panel Screen 3"4 Mono ETH W/P/R HMISTO532 On Request
4.3" touch panel screen RS232C HMISTO705 On Request
4.3" touch panel screen RS232C/485 HMISTO715 On Request
4.3" touch panel screen Ethernet HMISTO735 On Request
Customized STO735 HMISTO735AG On Request
Touch Panel Screen 3"5 Color HMISTU655 On Request
STU 3in5 without marking on overlay HMISTU655W On Request
Touch Panel Screen 5"7 Color HMISTU855 On Request
STU 5in7 without marking on overlay HMISTU855W On Request
Unit MRP
Product description Reference
[`]
GXU Touch Panel, 7"W TFT, SL only HMIGXU3500 On Request
GXU Touch Panel, 7"W TFT, SL + ETH HMIGXU3512 On Request
GXU Touch Panel, 10"W TFT, SL only HMIGXU5500 On Request
GXU Touch Panel, 10"W TFT, SL + ETH HMIGXU5512 On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 209
Vijeo XD EcoStruxure™ Operator Terminal Expert
Vijeo XD
Unit MRP
Product description Reference
[`]
Vijeo XD Pro License HMIPELCZLSPMZZ On Request
Vijeo XD Pro License Vendor HMIPELVZLSPMZZ On Request
Vijeo XD Pro License Vendor HMIPELVZLSPMZZ On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 210
Vijeo Vijeo Designer
Vijeo Designer
Unit MRP
Product description Reference
[`]
Vijeo Designer internal and partner pack VJDCLINTSV62M On Request
VJD V4.6 Facility No Cable VJDFNDTGSV46M On Request
Vijeo Designer, Licence Facility, No Cable VJDFNDTGSV47M On Request
Vijeo Designer, Facility license VJDFNDTGSV62M On Request
Vijeo Designer, Group license VJDGNDTGSV62M On Request
Vijeo Designer, Single License VJDSNDTGSV62M On Request
Vijeo Designer Magelis iPC RT VJDSNRTMPC On Request
Vijeo Designer Standard PC RT VJDSNRTSPC On Request
Vijeo Designer V5.1 I D S VJDSNTRCKV51M On Request
Vijeo Designer RT IDS license extension VJDSNTRCKV62M On Request
Pack Vijeo Designer RT IDS Report Print VJDSNTRPKV62M On Request
Vijeo Designer IDS Report Printing VJDSNTRPRV62M On Request
KIT XBTRT500 VJD LITE CBL VJDSTKXBTRT On Request
Vijeo Designer,Single License,USB cable VJDSUDTGAV62M On Request
Vijeo Designer, Team license VJDTNDTGSV62M On Request
Vijeo Designer Update License VJDUPDTGAV62M On Request
Vijeo Designer RT IDS Update license VJDUPTRCKV62M On Request
VJD IDS Report Printing Update license VJDUPTRPRV62M On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 211
Acti 9 Advanced Communication
Technology that Inspires
Innovative Efficient
Protection monitoring Total control and Manage loads, reduce operating and project
Metering @ DB level costs, and accurately plan maintenance
se.com/in 212
> Control and monitoring > Installation system
• Contactors • IP20B terminals
• Impulse relays • Splitter blocks
• Integrated control circuit breakers • Full range of mounting and
• Light indicators wiring accessories
• Push-buttons and selector switches
• Kilowatt hour meters
• Communicating architecture
Reliable
Dual certifications for one product, 100 percent MCB and RCD
coordination, easy ordering and design, error free fast connections
se.com/in 213
Acti 9 Advanced Communication
Technology that Inspires.....
> Innovative
• Centralized control system including energy metering
• Large and variable data reading and computing through universal Modbus protocol NEW
> Efficient
Email Notification upon
• One-click, prefabricated wiring for comprehensive communication between your
distribution board or panel and any facility management system Event (Devices Status
> Reliable Change, Alarm threshold
• Error proof connection leading to reduction in downtime reached etc.)
• EMC tested for immunity, radiated and conducted safety
Exclusive From
7 input/output Schneider Electric
channels
Load co
Protection monitoring
se.com/in 214
Ready to connect to any facility management solution
Energy Building
management Smart
management Internet Phone
PLC system
system
24 V DC
Power supply
Energy metering
ontrol switching
se.com/in 215
Acti 9 Miniature Circuit Breakers (MCBs)
for circuit protection against Overload and Short Circuit Current Fault
Advanced Communication
Technology that Inspires...
B curve
6 A9N1P06B 431 A9N2P06B 1280 A9N3P06B 2124 A9N4P06B 2861
10 A9N1P10B 431 A9N2P10B 1280 A9N3P10B 2124 A9N4P10B 3019
16 A9N1P16B 431 A9N2P16B 1280 A9N3P16B 2124 A9N4P16B 2861
20 A9N1P20B 431 A9N2P20B 1280 A9N3P20B 2124 A9N4P20B 2861
25 A9N1P25B 431 A9N2P25B 1280 A9N3P25B 2124 A9N4P25B 2861
32 A9N1P32B 431 A9N2P32B 1280 A9N3P32B 2124 A9N4P32B 2861
40 A9N1P40B 937 A9N2P40B 2060 A9N3P40B 3235 A9N4P40B 4120
50 - - - - A9N3P50B 3235 A9N4P50B 4196
63 A9N1P63B 949 A9N2P63B 2117 A9N3P63B 3262 A9N4P63B 4157
C curve
1 A9N1P01C 661 A9N2P01C 1773 A9N3P01C 2797 A9N4P01C 3521
2 A9N1P02C 661 A9N2P02C 1773 A9N3P02C 2797 A9N4P02C 3521
3 A9N1P03C 661 A9N2P03C 1773 A9N3P03C 2797 A9N4P03C 3521
4 A9N1P04C 661 A9N2P04C 1773 A9N3P04C 2797 A9N4P04C 3521
6 A9N1P06C 399 A9N2P06C 1280 A9N3P06C 2124 A9N4P06C 2861
10 A9N1P10C 399 A9N2P10C 1280 A9N3P10C 2124 A9N4P10C 2861
16 A9N1P16C 399 A9N2P16C 1280 A9N3P16C 2124 A9N4P16C 2861
20 A9N1P20C 399 A9N2P20C 1280 A9N3P20C 2124 A9N4P20C 2861
25 A9N1P25C 399 A9N2P25C 1280 A9N3P25C 2124 A9N4P25C 2861
32 A9N1P32C 399 A9N2P32C 1280 A9N3P32C 2124 A9N4P32C 2861
40 A9N1P40C 937 A9N2P40C 2060 A9N3P40C 3235 A9N4P40C 3941
50 A9N1P50C 937 A9N2P50C 2060 A9N3P50C 3235 A9N4P50C 4157
63 A9N1P63C 949 A9N2P63C 2079 A9N3P63C 3262 A9N4P63C 4228
D curve
1 A9N1P01D 668 A9N2P01D 1791 A9N3P01D 2841 ---- ----
2 A9N1P02D 668 A9N2P02D 1791 A9N3P02D 2841 A9N4P02D 3707
3 A9N1P03D 668 A9N2P03D 1791 A9N3P03D 2841 A9N4P03D 3808
4 A9N1P04D 668 A9N2P04D 1791 A9N3P04D 2841 A9N4P04D 3808
6 A9N1P06D 563 A9N2P06D 1342 A9N3P06D 2237 A9N4P06D 2968
10 A9N1P10D 563 A9N2P10D 1342 A9N3P10D 2237 A9N4P10D 2968
16 A9N1P16D 563 A9N2P16D 1342 A9N3P16D 2237 A9N4P16D 2968
20 A9N1P20D 563 A9N2P20D 1342 A9N3P20D 2237 A9N4P20D 2968
25 A9N1P25D 563 A9N2P25D 1342 A9N3P25D 2237 A9N4P25D 2968
32 A9N1P32D 563 A9N2P32D 1342 A9N3P32D 2237 A9N4P32D 2968
40 A9N1P40D 1011 A9N2P40D 2178 A9N3P40D 3426 A9N4P40D 4298
50 - - A9N2P50D 2178 A9N3P50D 3426 A9N4P50D 4298
63 A9N1P63D 1023 A9N2P63D 2204 A9N3P63D 3458 A9N4P63D 4341
Note: * Please contact nearest Schneider Electric Sales Office or Customer Care Center for coordination chart
**18mm/module
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 216
Acti 9 Miniature Circuit Breakers (MCBs)
for circuit protection against Overload and Short Circuit Current Fault
Advanced Communication
Technology that Inspires...
[In] Rated 1 Pole Unit MRP 2 Pole Unit MRP 3 Pole Unit MRP 4 Pole Unit MRP
Current (A) Reference [`] Reference [`] Reference [`] Reference [`]
Module Width** 1.5 mod 3 mod 4.5 mod 6 mod
MOQ 12 Nos. 6 Nos. 4 Nos. 3 Nos.
C120N (10kA)
80 A9N18357 3536 A9N18361 7836 A9N18365 12310 A9N18372 16042
100 A9N18358 3967 A9N18362 8359 A9N18367 13120 A9N18374 16715
125 A9N18359 4365 A9N18363 9187 A9N18369 14552 A9N18376 18917
C120H (15kA)
80 A9N18446 4359 A9N18457 9619 A9N18468 14467 A9N18479 20073
100 A9N18447 4899 A9N18458 9861 A9N18469 15761 A9N18480 22255
125 A9N18448 5254 A9N18459 11187 A9N18470 17009 A9N18481 23510
[In] Rated Module Width 18mm/ 1 Pole Unit MRP Module Width 18mm/ 2 Pole Unit MRP
Current (A) module Reference [`] module Reference [`]
MOQ 12 Nos. 6 Nos.
C60H-DC
0.5 1 A9N61500 1359 2 A9N61520 3621
1 1 A9N61501 1203 2 A9N61521 2483
2 1 A9N61502 1203 2 A9N61522 2483
3 1 A9N61503 1203 2 A9N61523 2483
4 1 A9N61504 1203 2 A9N61524 2483
5 1 A9N61505 1203 2 A9N61525 2483
6 1 A9N61506 988 2 A9N61526 2020
10 1 A9N61508 988 2 A9N61528 2020
16 1 A9N61511 988 2 A9N61531 2020
20 1 A9N61512 988 2 A9N61532 2020
25 1 A9N61513 988 2 A9N61533 2020
32 1 A9N61515 1138 2 A9N61535 2020
40 1 A9N61517 1354 2 A9N61537 2980
50 1 A9N61518 1354 2 A9N61538 2980
63 1 A9N61519 1354 2 A9N61539 2980
se.com/in 217
Acti 9 Miniature Circuit Breakers (MCBs)
for circuit protection against Overload and Short Circuit Current Fault
Advanced Communication
Technology that Inspires...
[In] Rated 1 Pole Unit MRP 2 Pole Unit MRP 3 Pole Unit MRP 4 Pole Unit MRP
Current (A) Reference [`] Reference [`] Reference [`] Reference [`]
Module Width** 1.5 mod 3 mod 4.5 mod 6 mod
**18mm/module
Note: Reference provided above are for C Curve MCBs – B and D Curve details available on request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 218
Residual Current Devices (RCDs) -
For Human and Fire Protection
Use of 30mA RCDs is now mandatory for all domestic intallations in India {CEA
Amendment regulation 2015*}
Schneider Electric provides voltage independent RCDs which work on current sensing
technology and provide protection from residual current even at extra low voltages
(down to zero volts) and in case of break of neutral.
se.com/in 219
Acti 9 Residual Current Devices
for protection against Risk of Shock / Electrocution and Risk of Fire
Advanced Communication
Technology that Inspires... in case of Earth Leakage Current.
[In] Rated Earth-Leakage Module Width 2 Pole Unit MRP Module Width 4 Pole Unit MRP
Current (A) Sensitivity (mA) 18mm/module Reference [`] 18mm/module Reference [`]
30 2 A9N16201 4449 4 A9N16251 6245
25 100 2 A9N16203 4938 4 A9N16253 6636
300 2 A9N16202 5088 4 A9N16252 6831
30 2 A9N16204 5236 4 A9N16254 6147
40 100 2 A9N16205 5646 4 A9N16255 6673
300 2 A9N16206 5921 4 A9N16256 6931
30 2 A9N16208 6305 4 A9N16258 7118
63 100 2 A9N16209 6781 4 A9N16259 7884
300 2 A9N16210 6918 4 A9N16260 7921
30 2 A9N16212 10601 4 A9N16261 12556
80 100 2 A9N16213 10778 4 A9N16262 12758
300 2 A9N16214 10979 4 A9N16263 12827
Note: Application specific RCDs also available with 10mA, 500mA and 1000mA sensitivities | Please contact nearest Schneider Electric Sales Office or
Customer Care Center for Reference and Prices
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 220
Acti 9 Residual Current Devices
for protection against Risk of Shock / Electrocution and Risk of Fire
Advanced Communication
Technology that Inspires... in case of Earth Leakage Current.
[In] Rated Earth-Leakage Module Width 2 Pole Unit MRP Module Width 4 Pole Unit MRP
Current (A) Sensitivity (mA) 18mm/module Reference [`] 18mm/module Reference [`]
25 30 2 A9N16234 10300 4 A9N16321 11479
40 30 2 A9N16237 10818 4 A9N16324 11841
30 2 A9N16240 11129 4 A9N16327 12158
63
300 2 A9N16246 11213 4 A9N16334 12649
[In] Rated Earth-Leakage Module Width 2 Pole Unit MRP Module Width 4 Pole Unit MRP
Current (A) Sensitivity (mA) 18mm/module Reference [`] 18mm/module Reference [`]
30 1.5 A9N26581 7284 3 A9N26595 8747
25 100 1.5 A9N26582 9265 3 A9N26596 9433
300 1.5 A9N26583 9796 3 A9N26597 10151
30 2 A9N26611 10184 3.5 A9N26643 10223
63 100 2 A9N26612 10785 3.5 A9N26644 10617
300 2 A9N26613 11297 3.5 A9N26645 11109
Note: Vigi Block for High Rating up to 125A (C120) and High Breaking Capacity (NG125) available on demand
*For Prices, please contact nearest Schneider Electric Sales Office or Customer Care Center are Center for Reference and Prices
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 221
Acti 9 Auxiliaries and Accessories for
Advanced Communication
Technology that Inspires...
MCBs / RCDs
54 mm max.
+ + + + + + +
Accessories
Unit MRP
Type Description Reference
[`]
Breaker Switching Sub-Assembly 27046 5115
Rotary Handle*
Extended, Disconnectable handle 27047 3166
Padlock** (bag of 2) 26970 1231
Multicable terminal for 3 copper cables** 19096 9898
Aluminum cable terminal** 27060 752
Spacer A9N27062 317
* for xC60, C120, DPN N Vigi, C60H-DC, xSW - Multi poles only
**for xC60, xID, DPN N Vigi, C60H-DC, xSW, C60PV-DC
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 222
Protection Against Lightning Strikes And
Switching Surges
90%
of power outlets
supply equipment
incorporating
electronic devices.
se.com/in 223
Acti 9 Surge Protection Devices
for protection of equipment against Lightning and Switching surges
Advanced Communication
Technology that Inspires...
Surge Arresters iPRD- Type 2 (Withdrawable type) (TT, TN-S, TN-C Systems)
• In conformance with standards IEC 61643-11/2011 T2 and EN 61643-11 Type 2
• For protection against Indirect lightning surge and Switching surge
• Inbuilt health Indicator
• Response time < 25ns
• lmax (8/20 s): 65/40/15/8kA
• Maximum Operating Voltage [Uc]: 340V
• Level of protection,Up: 1.0 - 2.0 kV
• Remote indication contact with 8r/20r/40r/65r
• Always use a Back-up MCB with your SPD
se.com/in 224
Acti 9 Surge Protection Devices
for protection of equipment against Lightning and Switching surges
Advanced Communication
Technology that Inspires...
Note: Spare / Replacement Cartridges available - For Reference and prices contact nearest sales office or customer care
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 225
Acti 9 Control and Command Products
for Load Control, Switching and Indication
Advanced Communication
Technology that Inspires...
Isolator - xSW
• Complies to IEC/EN 60947-3
• Switching duty: AC-22
• Impulse voltage: 6kV
• DC application: 48V (110V with 2 poles in series)
• Short circuit withstand 20 In for 1 second
• Upto 80A Bi connect terminals & 100A to 125A with mono connect terminals
iRO Buzzers
• Audible indication in housing and the tertiary sector
• Sound level of 70dBA at a distance of 60cm
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 226
Acti 9 Control and Command Products
for Load Control, Switching and Indication
Advanced Communication
Technology that Inspires...
iCT Contactors
• Complies with standards IEC 1095, E N 61095
• 4 operating modes switch on front face :
° Automatic mode
° Temporary “ON” mode
° Permanent “ON” mode
° Shutdown
• Mechanical contact position Indicator
• Safe installation maintainance: lock the contactor in ON position
• Silent operation (20dB) for entire range
Unit MRP
Type Rating (A) Control Voltage No. of Contacts Module Width Reference
[`]
16 230-240 VAC 1NO 1 A9C30811 1729
1P
32 230-240 VAC 1NO 1 A9C30831 2176
16 230-240 VAC 2NO 1 A9C30812 2835
2P
32 230-240 VAC 2NO 1 A9C30831 + A9C32836 6727
16 230-240 VAC 1NO+1NO/NC+1NO 2 A9C30811 + A9C32816 5380
3P
32 230-240 VAC 1NO+1NO/NC+1NO 2 A9C30831 + 2* x A9C32836 11278
16 230-240 VAC 4NO 2 A9C30814 5871
4P
32 230-240 VAC 4NO 2 A9C30831 + 3* x A9C32836 15829
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 227
Acti 9 ComReady Control and
Advanced Communication
Technology that Inspires...
Command Products
Smartlink
• Compliance to IEC/EN 61131-2
• Protection Monitoring – Device Status and alarm notifications
• Load Control / Switching through Contactors and Impulse Relays
• Energy Monitoring through pulse meters
• Alarm over email and analog sensors (temperature / humidity) with Smartlink
Ethernet
• Plug & Play – Pre fabricated cables and in built web pages
• Rated Voltage: 24V DC
Communication Auxiliaries
Acti 9
Description Reference Pack Unit MRP [`]
Distribloc 63A
Distribution from the top (4 Module) 04040 1 15571
Distribution through the bottom (4 Module) 04041 1 15571
[In] Rated 2 Pole Unit MRP 3 Pole Unit MRP 4 Pole Unit MRP
Current (A) Reference [`] Reference [`] Reference [`]
Module Width ** 4.5 mod 5.5 mod 6.5 mod 2275
B Curve
10 A9C61210 49082 A9C61310 51257 A9C61410 54948
16 A9C61216 49076 A9C61316 51257 A9C61416 54948
25 A9C61225 49076 A9C61325 51257 A9C61425 54948
40 A9C61240 50701 A9C61340 54818 A9C61440 58347
63 A9C61263 53926 A9C61363 56954 A9C61463 61661
C Curve
10 A9C62210 49632 A9C62310 52825 A9C62410 56074
16 A9C62216 49632 A9C62316 52830 A9C62416 56074
25 A9C62225 49626 A9C62325 52825 A9C62425 56074
40 A9C62240 52268 A9C62340 54844 A9C62440 58385
63 A9C62263 55077 A9C62363 56954 A9C62463 61666
D Curve
10 A9C63210 50752 A9C63310 53898 A9C63410 58327
16 A9C63216 50752 A9C63316 53898 A9C63416 58327
25 A9C63225 50752 A9C63325 53898 A9C63425 58327
Note: **18mm/module
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 228
Isobar Distribution System
70%
From sensors to services, our Innovation At Every Level
approach improves energy and operational efficiency by of decision-makers
tapping the true business value of IoT advancements. see the business
We’ve made mobility, sensing, cloud, analytics, and value of IoT*
cyber security technologies meaningful to customers, *Schneider Electric IoT 2020
Business Report
helping them compete in our IoT economy.
Edge Control
Connected Products
se.com/in 229
Introduction Isobar Distribution System
Connectivity built in
Acti9 Isobar harnesses the connectivity of the Acti9 range enabling
distribution boards to become smart and connected.
1
2. Smartlink SiD for wireless data
concentration
se.com/in 230
Acti 9
Isobar Pan Assembly
Fully encapsulated
busbar system
(IP2x)
Conversion of any
outgoing way into neutral
Wide range of
incomers
Fully shrouded
connection when main
switch is fitted
* - Price on Request
Please contact Schneider Electric Customer Care Center for Prices
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 231
Acti 9
Distribution Boards
Unique Rounded Corners | Color - RAL 9003 white | Designer Rotary Knob
Removed all
injurious sharp
corners
15% more wiring area | Reduced U-box Collar | Removable Frame, Centre plate & Gland plate
Surface and Flush installation | Field fittable key lock provision | Reversible Door
se.com/in 232
Inspiring the S.M.A.R.T. choice!!!
IK-08
Single Door
IK-09 Green
Double Door Product
NEW
4X Rust Resistance
1.Powder Coating
2.Galvanized Iron
3.Base Iron
se.com/in 233
Inspiring the S.M.A.R.T. choice!!!
Designed and Manufactured as per IS 8623 - 1 & 3 | IP and IK test by ERDA & CPRI | Glow wire tested
se.com/in 234
Acti 9
Distribution Boards
DB identification label Fast and Easy removal of Plastic Stud for easy
Revolutionary EPDM Gasket ensuring IP43
with manufacturing Gland Plate with reduced and safe removal of
protection and higher service life
details number of screws Center Plate
Convenient Installation
with Common com-
bihead screws for
both Centre Plate and
Frame
Embossed
earthing symbol
for easy
identification
throughout service
life
Door earthing to
protect against
electric shock
Interconnecting
FRLS wireset to limit
fire damage in case
of fault
Cement Spill Protector
provided with DB interior
to safeguard against Insulated phase
dust and cement busbars for fast and
during installation easy connection of
components and safety
during maintenance
se.com/in 235
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
Metal Enclosures
• Metal Enclosure to mount individual Modular Device feeding directly to the load
or final distribution board
SPN DBs
• SPN DB for distribution of Single Phase Neutral supply to respective load MCBs
• Incomer - DP RCCB/RCBO/Isolator/MCB
• Outgoing - SP MCBs
TPN DBs
• Standard TPN DBs for distribution of Three Phase and Neutral supply
• Incomer - FP RCCB/RCBO/Isolator/MCB
• Outgoing - SP MCBs
• TPN DBs can be converted to PPI DB using ‘PPI Kit’ provided on next page
se.com/in 236
Acti 9
Distribution Boards
GI RM for improved
resistance to rust
12 module incomer
DIN space
Key highlights
Please Contact nearest Schneider Electric Sales Office and Customer Care Center for your fererence.
se.com/in 237
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
PPI Kit (to convert TPN and Flexi Tier DBs to PPI DB)
• Set of accessories to convert TPN DBs and 4 tier Flexi DBs to PPI DB
• Kit is provided with additional required quantity of N-Bar, wire set, Busbars (only
for Flexi Tier) and Mounting Kit (only for TPN)
Unit MRP
Description Reference
[`]
PPI Kit for 6way TPN DB (2+4w PPI DB) A9HKIT04 4114
PPI Kit for 8way TPN DB (2+6w PPI DB) A9HKIT06 4818
PPI Kit for 12way TPN DB (2+10w PPI DB) A9HKIT10 5310
PPI Kit for 4T40M Flexi DB (2+8w PPI DB) A9HKIT08 8519
PPI Kit for 4T56M Flx DB (2+12w PPI DB) A9HKIT12 9432
se.com/in 238
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
ComReady DBs
• Designed to house Acti 9 communication system
• Supplied with Double DIN rail, E-Bar and Wire channel.
• Accessories to convert Flexi Tier DB into ComReady DB available on request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 239
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
• Plug & Socket Unit with provision to mount PratiKa straight / angled* socket and
modular protection devices to feed the end load directly
Key Lock*
Unit MRP
Description Reference
[`]
Acti9 key lock A9HRL802 932
New Rotary Lock** A9HRL901 742
Note: **Use New Rotary lock reference A9HRL901 for:
Acti9 DBs manufactured September 2020 onwards
Acti9 DBs with lock & unlock symbol on door.
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 240
Acti 9 Modular Distribution Boards - Metallic
Advanced Communication
Technology that Inspires...
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 241
Kaedra Enclosures Weather Proof
Kaedra enclosures for PratiKa industrial sockets are part of a complete system of Watertight enclosures from
16A to 125A providing solutions for protection, control and electrical distribution for tertiary and industrial
applications
Unit MRP
Description Reference
[`]
4 module 13441 3783
6 module 13442 4306
8 module 13443 5071
12 module 13444 8147
Unit MRP
Description Reference
[`]
1 row 12 module 13431 8991
1 row 18 module 13432 11850
2 row 24 module 13433 13457
2 row 36 module 13434 17035
3 row 36 module 13435 17763
4 row 72 module 13437 33904
Mini Enclosure (suitable to mount modular devices and PratiKa 16A socket)
Unit MRP
Description Reference
[`]
4 module 1 vertical opening 13175 1805
4 module 2 horizontal opening 13176 2226
4 module 3 horizontal opening 13177 2802
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 242
Kaedra Enclosures Weather Proof
Enclosure (suitable to mount modular devices and PratiKa 16A / 32A sockets)
Unit MRP
Description Reference
[`]
5 module 2 opening 13178 4344
8 module 4 horizontal opening 13179 5929
13 module 3 opening 13180 7835
13 module 6 opening 13181 8613
19 module 8 opening 13182 11100
Functional Plaques
Unit MRP
Description Reference
[`]
Blank - marked for 1 socket 50x50 13135 562
Blank - marked for 1 socket 65x65 or 75x75 13137 562
Intermediate with 65x85 opening 13136 685
Intermediate with one opening for 65x85 & 90x100 13142 1136
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 243
PratiKa Plugs and Sockets - IP44 / IP67
Wander Plugs
• Conforms to IEC 60309-1 & IEC 60309-2
• PK PratiKa Screw Connect: same orientation of clamp’s screws
• External impact strength: IK08
• Glow wire test: 850°C
PKE16M423 PKE16M723 81383
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 244
PratiKa Plugs and Sockets - IP44 / IP67
Wander Sockets
• PK PratiKa Screw Connect: same orientation of clamp’s screws.
• PK PratiKa: 16A & 32A; IP44 & IP67
• External impact strength: IK08
• Glow wire test: 850 °C
PKF16M423 81483 PKF32M735 • Conforms to IEC 60309-1 & IEC 60309-2
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 245
PratiKa Plugs and Sockets - IP44 / IP67
se.com/in 246
PratiKa Plugs and Sockets - IP44 / IP67
Socket with Interlock Switch & DIN Rail lsoblock (4.5 modules )
• Switch designed for use in AC- 22A class applications
• Conforms to IEC 60309-1 & IEC 60309-2
• Provision to DIN mount 4.5 module device
• External impact strength: IK10
• Available in IP65 version
• Glow wire test: 850°C
82754 83796
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 247
Electra Metal Clad Plugs & Sockets
ELECTRA Metal Clad Plugs & Sockets are specially designed incorporating the latest safety, quality and user
friendly features.
Construction
• The casting is made from non-corroding die-cast aluminum alloy combining exceptional compactness with high strength
• The design/construction eliminates the possibility of mismatch in fitting of plugs in corresponding sockets
• The floating contacts in the sockets are self aligning and facilitates smooth plugging in without undue pressure (These can be easily
removed for wiring )
• A provision for pilot pin facilitates mechanical interlocking in case of 63A ratings
Human Safety
Specially designed shroud to avoid accidental finger contact with plug-pins while inserting/removing the plug
Similarly, the contact tubes in sockets are deeply recessed to avoid human contact
• The earthing pins ensure that earth connection is made first and broken last, being longer than conducting pins
• The visible earth terminals facilitate easy checking of earth connection
• The cable grip to the plug is made very strong by providing a compression gland and by protecting it at the point of entry by a strong
rubber guard
Applications
Industrial, Commercial & Domestic portable equipments like Hand/Power Tools, Industrial Ovens, Welding Sets, Mobile Generators,
Furnaces, Ships, Office Machines, Refrigerators, Coolers, Air-Conditioners, Overhead Cranes, Chilling Cabinets, Tile Polishers and
Sewing Machines
Plug
Unit MRP
Rating (A) Poles Description Voltage (V) MOQ Reference
[`]
10 2P 250 30 AP10 262
20 2P 250 30 AP20 275
20 3P 440 30 BP20 366
30 3P 440 20 BP30 667
63 3P+N+E 440 4 CP63 3015
Socket
Unit MRP
Rating (A) Poles Description Voltage (V) MOQ Reference
[`]
10 2P 250 30 AS10 275
20 2P 250 30 AS20 293
20 3P 440 30 BS20 411
30 3P 440 20 BS30 706
63 3P+N+E 440 4 CS63 3313
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 248
Power
EasyLogicTM series of
Multifunction meters to
optimize Industry Performance
se.com/in
se.com/in 249
Discover Our Power Monitoring Solutions
Advanced PQ
High revenue Accuracy | High speed Transient
Detection | Waveform Capturing – Sag| Swell |
Patented DDD | GPS time sync | SOE | IEC PQ
ION9000
Compliance
Advanced Utility
High revenue Accuracy, transient
detection, ABT application, Embedded
web pages, Modbus mastering, GPS time
sync, IEC PQ Compliance
ION8650 ION7400
Intermediate PQ
Patented Disturbance detection,
Intermediate PQ, RCM, on board memory,
alarms, waveform capture,
sags & swells, smart demand controller
PM8000 EM7200 PM53/55/56/57XX
Multifunction Meters
Energy | Power | Demand | RTC |
Multitariff, Calibration LED |
Expandable DIDO | AIAO
PM2000 EM6400NG+ EM6436H | PM1130H iEM3000
se.com/in 250
1. Tailored Offers for Specific Applications and Segments
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 251
Advanced metering for
the new electric world
PowerLogic™ PM8000, ION9000 and ION9000T
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 252
PowerLogic™ PM8000, ION9000 and ION9000T
Advanced metering for the new electric world
Tangible results
The ION9000 saves you valuable time from examining raw data
and extracts tangible results from the data set to convey the
information needed to get real results. Designed so you can
prevent a severe power quality event occurrence or recover
quickly from such events.
Wide versatility
A modular architecture and an easy-to-use block-oriented
programming architecture make our advanced power meters
the ideal instruments to help original equipment manufacturers
or system integrators evolve and adapt to changing business
realities.
* Requires PME
** Please refer to product catalogue for details
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 253
2. High Accuracy, Specialized Solutions - for MV/LV Distribution
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 254
2. High Accuracy, Specialized Solutions - for MV/LV Distribution
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 255
PowerLogic™
PM55/56/5700
Power quality, features in a
cost-effective, precision meter
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 256
3. High Accuracy, Compact, Power Meters - for HV/MV/LV Distribution
Unit MRP
Product Description Reference
[`]
Cl0.2S, 2 Ethernet + 1 RS485 Port, 4th CT, Webpage, 63rd Harmonic (magnitude &
PM 5560 30003008D 70023
direction), 52 alarms, 4 DI, 2 DO, 8 multi tariff, 128 samples / cycle
CI0.5S, 1 Ethernet, 31st harmonic, 2 DI, 2 DO, 2 RO, 35 Alarms, Data logging,
PM 5340 30003007D 40958
64samples / cycle
CI0.5S, 1 Ethernet, 31st harmonic, 2 DI, 2 DO, 35 Alarms, Data logging, 64samples /
PM 5320 30003005D 38175
cycle
Unit MRP
Product Description Reference
[`]
EM 7290 Demand Controller Cl0.2* with RS485 Port 30002975 55763
EM 7280 Demand Controller Cl0.5S with RS485 Port 30002198 43500
EM 7230 Demand Controller Cl1.0 with RS485 Port 30002055 40153
* Class 0.2S compliance available in 3ph,4w system
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 257
The easy choice for quality,
value, and simplicity.
EasyLogicTM PM2000 series
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 258
3. High Accuracy, Specialized Solutions- for MV/LV Distribution
Unit MRP
Product Description Reference
[`]
PM2230, LCD, RS485, Accuracy Cl0.5S, 31st Ind.harmonics, 12am snap shot, kg CO2
PM2230 METSEPM2230D 29576
and energy rate counters, Data logging
PM2220, LCD, RS485, Accuracy Cl1, 15th Ind.harmonics, 12am snap shot, kg CO2
PM2220 METSEPM2220D 27208
and energy rate counters
PM2130, LED, RS485, Accuracy Cl0.5S, Ind. Harmonics up to 31st over communica-
PM2130 METSEPM2130D 28328
tion, data logging
PM2K2DIDO* Optional Digital IO card - 2 channel DI & DO for PM2000 Series METSEPM2KDGTLIO22D 3361
PM2K1AIAO* Optional Analog IO card - 1 channel AI & AO for PM2000 Series METSEPM2KANLGIO11D 3985
PM2K2AIAO* Optional Analog IO card - 2 channel AI & AO for PM2000 Series METSEPM2KANLGIO22D 4855
PM2K2DI2RO* EasyLogicTM PM2x30 2DI2RO Module 2-IO METSEPM2K2DI2ROD On Request
* Optional IO modules can be used for PM2230 & PM2130 models only. Maximum upto 1 module can be used per device at a time.
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 259
The future of multifunction
meters is here
Hexa and EM6400NG+ Series
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 260
4. India’s Most Trusted, Reliable and Accurate Multifunction Meters
Unit MRP
Product Description Reference
[`]
EM6400NG+ Class accuracy CI0.2, RS485 port METSEEM6400NGRSCL2 29487
EM6400NG+ Class accuracy CI0.5S, RS485 port METSEEM6400NGRSCL5 23686
EM6400NG+ Class accuracy Cl1.0, RS485 port METSEEM6400NGRSCL1 18696
EM6400NG+ Class accuracy CI0.5S, POP METSEEM6400NGPOCL5 16196
EM6400NG+ Class accuracy Cl1.0, POP METSEEM6400NGPOCL1 14663
Unit MRP
Product Description Reference
[`]
EASYLOGICTM PM1130H Dual Source Power & Energy Meter, Class accuracy
PM1130H METSEPM1130HCL05RD 17127
0.5, 01 Relay Contact, 01 RS485 port
EasyLogicTM EM6438H Dual Power & Energy Meter, Class accuracy 0.5, 01
EM6438H METSEEM6438HCL05RS 8412
RS485 port
EasyLogicTM EM6438H Dual Power & Energy Meter, Class accuracy 1.0, 01
EM6438H METSEEM6438HCL10RS 7809
RS485 port
EasyLogicTM EM6436H VAF+ PF + Power & Energy Meter, Class accuracy
EM6436H METSEEM6436HCL05RS 12547
0.5, 01 RS485 port
EasyLogicTM EM6436H VAF+ PF + Power & Energy Meter, Class accuracy
EM6436H METSEEM6436HCL10RS 10930
1.0, 01 RS485 port
EM6436H EasyLogicTM EM6436H VAF+ PF + Power & Energy Meter, Class accuracy 1.0 METSEEM6436HCL10NC 9351
EasyLogic TM EM6433H A+ Power & Energy Meter, Class accuracy 0.5, 01
EM6433H METSEEM6433HCL05RS 7801
RS485 port
EasyLogicTM EM6433H A+ Power & Energy Meter, Class accuracy 1.0, 01
EM6433H METSEEM6433HCL10RS 7349
RS485 port
EM6459H EasyLogicTM EM6459H VAF+ PF Digital Meter, Class accuracy 0.5, 01 RS485 port METSEEM6459HCL05RS 8288
EM6459H EasyLogicTM EM6459H VAF+ PF Digital Meter, Class accuracy 1.0, 01 RS485 port METSEEM6459HCL10RS 7775
EM6459H EasyLogicTM EM6459H VAF+ PF Digital Meter, Class accuracy 1.0 METSEEM6459HCL10NC 6073
TM
* Conzerv is now EasyLogic
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 261
5. India’s Most Trusted, Reliable and Accurate Multifunction Meters
Unit MRP
Product Description Reference
[`]
PM1230H EasyLogicTM PM1230H Dual Source Power & Energy, Class Accuracy 0.5, 01 RS485 Port METSEPM1230HCL5 16480
PM1225H EasyLogicTM PM1225H Restricted MFM Meter, Class Accuracy 0.5, 01 RS485 Port METSEPM1225HCL5 22877
PM1225H EasyLogicTM PM1225H Restricted MFM Meter, Class Accuracy 1.0, 01 RS485 Port METSEPM1225HCL1 18056
EM1220H EasyLogicTM EM1220H Load Manager, Class Accuracy 0.5, 01 RS485 Port METSEEM1220HCL5 12152
EM1220H EasyLogicTM EM1220H Load Manager, Class Accuracy 1.0, 01 RS485 Port METSEEM1220HCL1 10586
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 262
Stay on top of it
with PowerTag
se.com/powertag
* Secure it: As part of the Acti 9 communication system, PowerTag monitors loads and identifies load imbalances and overload levels before a trip
occurs. PowerTag also alerts you to voltage losses, so you save time recovering your installation in the event of load downtime. An email alert
means you can take preventive action thus avoiding potential downtime. © 2020 Schneider Electric. All Rights Reserved. Life Is On Schneider Electric is
a trademark
Please and the
contact property of
Customer Schneider
care centerElectric SE, its subsidiaries
for Stockable and Nonand affiliated status
stockable companies. 998-20959054_GMA_630A_image63A_PanelBuilder_
of references.
print ad.indd
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 263
6. PowerTag - World’s Smallest Energy Sensor
Unit MRP
Product Description Reference
[`]
PowerTag PowerTag Energy M63 1P+W A9MEM1520 8932
PowerTag PowerTag Energy M63 1P+N Top A9MEM1521 8932
PowerTag PowerTag Energy M63 1P+N Bottom A9MEM1522 8932
PowerTag PowerTag Energy M63 3P A9MEM1540 18030
PowerTag PowerTag Energy M63 3P+N Top A9MEM1541 18030
PowerTag PowerTag Energy M63 3P+N Bottom A9MEM1542 18030
PowerTag PowerTag Energy F63 1P+N A9MEM1560 9814
PowerTag PowerTag Energy F63 3P+N A9MEM1570 19652
PowerTag PowerTag Energy Sensor 63A -3P/3P+N A9MEM1573 18716
PowerTag PowerTag Energy Sensor 160A -F160 - 3P/3P+N A9MEM1580 24168
PowerTag PowerTag Energy Sensor Rope 200A - R200 - 3P/3P+N A9MEM1590 45283
PowerTag PowerTag Energy Sensor Rope 600A - R600 - 3P/3P+N A9MEM1591 47315
PowerTag PowerTag Energy Sensor Rope 800A - R1000 - 3P/3P+N A9MEM1592 50577
PowerTag PowerTag Energy Sensor Rope 2000A - R2000 - 3P/3P+N A9MEM1593 53025
Unit MRP
Product Description Reference
[`]
PowerTag ENERGY SENSOR POWERTAG NSX - 250A 3P LV434020 30985
PowerTag ENERGY SENSOR POWERTAG NSX - 250A 3P+N LV434021 33960
PowerTag ENERGY SENSOR POWERTAG NSX - 630A 3P LV434022 53555
PowerTag ENERGY SENSOR POWERTAG NSX - 630A 3P+N LV434023 58656
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 264
6. PowerTag - World’s Smallest Energy Sensor (cont.)
6.3 Smartlink
> Compliance to IEC/EN 61131-2
> Protection Monitoring – Device Status and alarm notifications
> Load Control / Switching through Contactors and Impulse Relays
> Energy Monitoring through pulse meters
> Alarm over email and analog sensors (temperature / humidity) with
Smartlink Ethernet
> Plug & Play – Pre fabricated cables and in built web pages
> Rated Voltage: 24V DC
Unit MRP
Product Description Reference
[`]
Smartlink Smartlink Modbus A9XMSB11 42919
Smartlink PowerTag Link A9XMWD20 25178
Smartlink Smartlink SI-B A9XMZA08 48277
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 265
EcoStruxure
Facility Expert
Boost building performance and operating
efficiency while reducing energy costs
se.com/ecostruxure-facility-expert
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 266
With Schneider Electric Partners,
installation is easy
Energy Features
Energy cost
Operations Features
Custom alarms on threshold and status change (eg. Temperature, open-close contact)
IOS Android
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 267
7. DIN Rail Mount Meters - Accurate, Flexible Power Meters
Three phase CT Operated, Din Rail Meter / Direct Current-Three phase (upto 63A)
iEM 32xx Cl0.5S CT iEM 31xx Cl1.0 - Direct current
Product Unit MRP Unit MRP
Reference Reference
[`] [`]
iEM 3x65 A9MEM3265 20818 A9MEM3165 20198
iEM 3x55 A9MEM3255 14592 A9MEM3155 16122
iEM 3x50 A9MEM3250 13683 A9MEM3150 15217
iEM 3x10 A9MEM3210 12534 A9MEM3110 13930
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 268
IoT for an intelligent
power network
EcoStruxure™ Panel Server
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 269
EcoStruxure™ Panel Server
IoT for an intelligent power network
All-in-one gateway
• Separates your OT network from your IT network
• Wireless data concentrator
• Modbus RS485 to Modbus TCP
• Supports multiple Ethernet connections for serving information
to edge control software and cloud applications
Simple commissioning
• EcoStruxure Power Commission software
• Device auto discovery
• Generation of acceptance reports to validate gateway
configuration
• Commission via Bluetooth® or WiFi
Intuitive operation
• User-friendly webpages offer first-level monitoring
• Contextualized data and operational insights
• Simple alarm setup for email notification
• Standardized IEC 62974-1 compliant datalogger and energy
server
Architecture overview
S
Schneider Electric Eco
EcoStruxure Po
Power Monitoring Expert
ccloud services Pa
Panel Server or third-party edge controls
we
webpages
Gas meter
Gas
meter
Ethernet or WiFi LAN Modbus Serial Line Analog/Digital IOs Wireless devices
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 270
8. Ethernet Communication Gateways
> Retrieve data from wireless & Modbus devices > Protocol Converter from Modbus RS485 to
> Connect to edge control systems & cloud TCP/IP
applications > Two (2) Ethernet ports for daisy chain
> Plug & Play easy commissioning Ethernet
> User friendly embedded webpages > Setup through built-in web pages
> Cybersecurity at the core > HTTP, HTTPS, FTP, SMTP, IPV6 Support
> 24V DC and/or POE power supply
Unit MRP
Product Description Reference
[`]
Link150 Protocol Converter EGX150
Panel Server Univeral with 24V DC power supply PAS600L 34721
Panel Server Universal
Panel Server Univeral with 100-277 V AC/DC power supply PAS600
Unit MRP
Description Reference
[`]
Adaptor Plate 144X144 mm 30000089 109
ELF adaptor plate 30001808 65
DM52XX Tamper protection kit - Set of 36 nos in 01 KIT METSEDM5240TK 1253
IP65 protection cover for PM5XXX, PM2XXX, NG+ and Hexa METSEIP65OP96X96FD On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 271
9. Specialized Small Form Factor Meters - ELF Series
Unit MRP
Product Description Reference
[`]
EM1200 EM1200 CI0.5 RS 30002572 4999
EM1000 EM1000 CI0.5 POP 30002571 4291
EM1200 EM1200 CI1.0 RS 30002565 4120
EM1000 EM1000 CI1.0 POP 30002568 3394
Unit MRP
Product Description Reference
[`]
DM6300 DM6300 CI0.5 RS 30002570 4119
DM6100 DM6100 CI0.5 30002569 3251
DM6300 DM6300 CI1.0 RS 30002566 3923
DM6100 DM6100 CI1.0 30002567 3097
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 272
11. CE compliance - Volt/Amp/ frequency meter
Unit MRP
Product Description Reference
[`]
DM3210 Three phase Voltmeter CI0.5 30002965 2908
DM3110 Three phase Ammeter CI0.5 30002964 2908
DM1210 Single phase Voltmeter CI0.5 30002962 1973
DM1110 Single phase Ammeter CI0.5 30002961 1973
DM1310 Frequency meter CI0.2 30002963 1502
Unit MRP
Product Description Reference
[`]
DM3210 Three phase Voltmeter CI0.5 30002462 2371
DM3110 Three phase Ammeter CI0.5 30002461 2371
DM3210 Three phase Voltmeter CI1.0 30002386 1895
DM3110 Three phase Ammeter CI1.0 30002385 1895
DM1210 Single phase Voltmeter CI0.5 30002460 1605
DM1110 Single phase Ammeter CI0.5 30002459 1605
DM1210 Single phase Voltmeter CI1.0 30002366 1192
DM1110 Single phase Ammeter CI1.0 30002365 1192
DM1310 Single phase Frequency CI0.2 30002367 1192
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 273
The most versatile meter for
your feeder applications
PowerLogic ION7400
• Compact, 3-phase multifunction energy and power quality compliance meters
• Flexible and modular, with object-oriented intelligence
• Accurate, precise, and highly adaptable
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 274
Purpose-built to keep your
power reliable and efficient
EcoStruxure™ Power Monitoring Expert
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 275
The power of a SCADA uniquely designed
for critical power management
EcoStruxure™ Power Operation
Power availability
Reduce downtime caused by electrical outages for optimum continuity
and reliability. Using machine-learning algorithms and automation,
Maximize power
Power Operation improves situational awareness to speed analysis and reliability and uptime
reduces the time required for your operators and engineers to discover
root causes.
se.com/in
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 276
VarPlus Box Xtreme
Built to perform in Xtreme
conditions
• Designed for 60ºC, offers upto 60% more life than products
designed at 55ºC
• Tested to perform upto 150,000 hrs life in standard operating
conditions
• Xtreme inrush withstand of upto 350 x In
• Designed to work in Xtreme environments
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 277
Power Factor Correction Products
VarPlus Can
Performance: High performance and flexibility
Offer configuration: Available in three configurations as FastOn, Clamptite and
Stud Offer
Product range: 1-50 kvar from 440V-525V
Product compliance: IEC 60831 Part 1-2014 and 2 -2014 compliant,
BIS Certified, CE, CQC, UL, ASTA, Rohs and Green Premium
Type tested: From LCIE France and ASTA Intertek
Temperature class: Class D (+55°C for VarPlus Can)
Reliability: Self healing, unique 3-phase disconnection mechanism with
pressure sensitive disconnection (PSD)
Safety: Tamper-proof discharge resistor, IP20 for FastOn and Clamptite offer
Robust design: Al Can for casing, hermetically sealed, resin as coolant -
better than gas
Enhanced life: 130K hours with better current handling capacity due to wave cut
films with slope metalization
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 278
Power Factor Correction Products
VarPlus Box
Performance: High performance and flexibility
Product range: 5-50 kvar from 440V-525V
Product compliance: IEC 60831 Part 1-2014 and 2 -2014 compliant,
BIS Certified, CE, CQC, UL, ASTA, Rohs and Green Premium
Type tested: From LCIE France and ASTA Intertek
Temperature class: +50°C for VarPlus Box APP,
Class D (60°C for VarPlus Xtreme Box, 70°C for MD-XL)
Reliability: Self healing, unique 3-phase disconnection mechanism with
pressure sensitive disconnection (PSD)
Robust design: Steel enclosure, resin as coolant - better than gas
Enhanced life: 150K hours with better current handling capacity due to wave cut
films with slope metalization
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 279
Power Factor Correction Products
MPP - Xtreme Heavy Duty Box 3Ph 5.6kVAr 480V 50Hz 5.6 1 MEHVBHDY056A48 3528
MPP - Xtreme Heavy Duty Box 3Ph 11.3kVAr 480V 50Hz 11.3 1 MEHVBHDY113A48 6088
MPP - Xtreme Heavy Duty Box 3Ph 14.4kVAr 480V 50Hz 14.4 1 MEHVBHDY144A48 7798
MPP - Xtreme Heavy Duty Box 3Ph 17kVAr 480V 50Hz 17 1 MEHVBHDY170A48 9155
MPP - Xtreme Heavy Duty Box 3Ph 22.4kVAr 480V 50Hz 22.4 1 MEHVBHDY224A48 12018
MPP - Xtreme Heavy Duty Box 3Ph 25kVAr 480V 50Hz 25 1 MEHVBHDY250A48 13418
MPP - Xtreme Heavy Duty Box 3Ph 28.1kVAr 480V 50Hz 28.1 1 MEHVBHDY281A48 15152
MPP - Xtreme Heavy Duty Box 3Ph 31.5kVAr 480V 50Hz 31.5 1 MEHVBHDY315A48 16902
VarPlus Box Energy (MD-XL) 480V Range
Energy - MD-XL Box 3Ph 5.6kVAr 480V 50 Hz 5.6 1 MEHVBENY056A48 5755
Energy - MD-XL Box 3Ph 6.7kVAr 480V 50 Hz 6.7 1 MEHVBENY067A48 6877
Energy - MD-XL Box 3Ph 11.3kVAr 480V 50 Hz 11.3 1 MEHVBENY113A48 11097
Energy - MD-XL Box 3Ph 14.4kVAr 480V 50 Hz 14.4 1 MEHVBENY144A48 14149
Energy - MD-XL Box 3Ph 15.5kVAr 480V 50 Hz 15.5 1 MEHVBENY155A48 15238
Energy - MD-XL Box 3Ph 17kVAr 480V 50 Hz 17 1 MEHVBENY170A48 16706
Enegry - MD-XL Box 3Ph 22.4kVAr 480V 50 Hz 22.4 1 MEHVBENY224A48 22013
Energy - MD-XL Box 3Ph 25.0kVAr 480V 50 Hz 25 1 MEHVBENY250A48 24577
Energy - MD-XL Box 3Ph 28.1kVAr 480V 50 Hz 28.1 1 MEHVBENY281A48 27625
* Refer to Selection chart for Reactors & Capacitors available on page 287
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 280
Power Factor Correction Products
* Refer to Selection chart for Reactors & Capacitors available on page 287
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 281
Power Factor Correction Products
MPP - Xtreme Heavy Duty Box 3Ph 6.9kVAr 525V 50Hz 6.9 1 MEHVBHDY069A52 4368
MPP - Xtreme Heavy Duty Box 3Ph 12.5kVAr 525V 50Hz 12.5 1 MEHVBHDY125A52 6712
MPP - Xtreme Heavy Duty Box 3Ph 13.8kVAr 525V 50Hz 13.8 1 MEHVBHDY138A52 7423
MPP - Xtreme Heavy Duty Box 3Ph 15.4kVAr 525V 50Hz 15.4 1 MEHVBHDY154A52 8284
MPP - Xtreme Heavy Duty Box 3Ph 17.2kVAr 525V 50Hz 17.2 1 MEHVBHDY172A52 9338
MPP - Xtreme Heavy Duty Box 3Ph 20.6kVAr 525V 50Hz 20.6 1 MEHVBHDY206A52 11083
MPP - Xtreme Heavy Duty Box 3Ph 25kVAr 525V 50Hz 25 1 MEHVBHDY250A52 13469
MPP - Xtreme Heavy Duty Box 3Ph 27.5kVAr 525V 50Hz 27.5 1 MEHVBHDY275A52 14808
MPP - Xtreme Heavy Duty Box 3Ph 30.6kVAr 525V 50Hz 30.6 1 MEHVBHDY306A52 16425
MPP - Xtreme Heavy Duty Box 3Ph 33.1kVAr 525V 50Hz 33.1 1 MEHVBHDY331A52 17913
MPP - Xtreme Heavy Duty Box 3Ph 37.7kVAr 525V 50Hz 37.7 1 MEHVBHDY377A52 20235
VarPlus Box Energy (MD - XL) 525V Range
Energy - MD-XL Box 3Ph 6.9kVAr 525V 50 Hz 6.9 1 MEHVBENY069A52 7091
Energy - MD-XL Box 3Ph 12.5kVAr 525V 50 Hz 12.5 1 MEHVBENY125A52 12389
Energy - MD-XL Box 3Ph 13.8kVAr 525V 50 Hz 13.8 1 MEHVBENY138A52 13686
Energy - MD-XL Box 3Ph 20.6kVAr 525V 50 Hz 20.6 1 MEHVBENY206A52 20400
Energy - MD-XL Box 3Ph 25kVAr 525V 50 Hz 25 1 MEHVBENY250A52 24774
Energy - MD-XL Box 3Ph 30.6kVAr 525V 50 Hz 30.6 1 MEHVBENY306A52 30311
Energy - MD-XL Box 3Ph 33.1kVAr 525V 50 Hz 33.1 1 MEHVBENY331A52 32771
Energy - MD-XL Box 3Ph 37.7kVAr 525V 50 Hz 37.7 1 MEHVBENY377A52 37357
VarPlus Box APP 525V Range
APP - Box 3Ph 6.9kVAr 525V 50Hz 6.9 1 MEHVBAPP069A52 6359
APP - Box 3Ph 12.5kVAr 525V 50Hz 12.5 1 MEHVBAPP125A52 10125
APP - Box 3Ph 13.8kVAr 525V 50Hz 13.8 1 MEHVBAPP138A52 11173
APP - Box 3Ph 15.4kVAr 525V 50Hz 15.4 1 MEHVBAPP154A52 12469
APP - Box 3Ph 17.2kVAr 525V 50Hz 17.2 1 MEHVBAPP172A52 13954
APP - Box 3Ph 20.6kVAr 525V 50Hz 20.6 1 MEHVBAPP206A52 16688
APP - Box 3Ph 22.6kVAr 525V 50Hz 22.6 1 MEHVBAPP226A52 18315
APP - Box 3Ph 25kVAr 525V 50Hz 25 1 MEHVBAPP250A52 20255
APP - Box 3Ph 27.5kVAr 525V 50Hz 27.5 1 MEHVBAPP275A52 22279
APP - Box 3Ph 30.6kVAr 525V 50Hz 30.6 1 MEHVBAPP306A52 24801
APP - Box 3Ph 33.1kVAr 525V 50Hz 33.1 1 MEHVBAPP331A52 26813
APP - Box 3Ph 37.7kVAr 525V 50Hz 37.7 1 MEHVBAPP377A52 30555
Refer to Selection chart for Reactors & Capacitors available on page 287
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 282
VarPlus MAX
Detuned Reactors
MAXimize Efficiency
MAXimize Savings
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 283
PFC - Detuned Reactors
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 284
Introducing
VarPlus MAX Copper
Wound Reactors
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 285
Copper Wound Detuned Reactor
Minimum
kVAr Unit MRP
Description Ordering Reference
Rating [`]
Quantity (No.)
Varplus Copper Detuned Reactor 7%, 440V Range
DetunedReactor CU 5kVAr 440V 7% 50Hz 5 1 LVR07050A44CU 12931
DetunedReactor CU 10kVAr 440V 7% 50Hz 10 1 LVR07100A44CU 21127
DetunedReactor CU 12.5kVAr 440V 7% 50Hz 12.5 1 LVR07125A44CU 23935
DetunedReactor CU 15kVAr 440V 7% 50Hz 15 1 LVR07150A44CU 25616
DetunedReactor CU 20kVAr 440V 7% 50Hz 20 1 LVR07200A44CU 27191
DetunedReactor CU 25kVAr 440V 7% 50Hz 25 1 LVR07250A44CU 31346
DetunedReactor CU 50kVAr 440V 7% 50Hz 50 1 LVR07500A44CU 53313
DetunedReactor CU 100kVAr 440V 7% 50Hz 100 1 LVR07X00A44CU 97913
Varplus Copper Detuned Reactor 14%, 440V Range
DetunedReactor CU 10kVAr 440V 14% 50Hz 10 1 LVR14100A44CU 25809
DetunedReactor CU 25kVAr 440V 14% 50Hz 25 1 LVR14250A44CU 50205
DetunedReactor CU 50kVAr 440V 14% 50Hz 50 1 LVR14500A44CU 83744
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 286
Selection of capacitor (kVAr & Voltage) for Detuned filter
Application
Effective kVAr output of Selection of 480V capacitors Selection of 525V capacitors Selection of 525V capacitors
Detuned Filter @ 440V for 7%/ 5.7% detuned Reactor for 7%/ 5.7% detuned Reactor for 14% detuned Reactor
for 440V for 440V for 440V
5kVAr 7%/5.7% Reactor 5kVAr 7%/5.7% Reactor 5kVAr 14% Reactor + 6.9kVAr,
5
+ 5.6kVAr, 480VCapacitor + 6.9kVAr, 525V Capacitor 525VCapacitor
10kVAr 7%/5.7% Reacor 10kVAr 7%/5.7% Reacor 10kVAr 14% Reacor + 12.5kVAr,
10
+ 11.3kVAr, 480V Capacitor + 13.8kVAr, 525V Capacitor 525V Capacitor
12.5kVAr 7%/5.7% Reactor 12.5kVAr 7%/5.7% Reactor 12.5kVAr 14% Reactor + 15.4kVAr,
12.5
+ 14.4kVAr, 480V Capacitor + 17.2kVAr, 525V Capacitor 525V Capacitor
15kVAr 7%/5.7% Reactor 15kVAr 7%/5.7% Reactor 15kVAr 14% Reactor + 18.5kVAr,
15
+ 17kVAr, 480VCapacitor + 20.6kVAr, 525V Capacitor 525V Capacitor
20kVAr 7%/5.7% Reactor 20kVAr 7%/5.7% Reactor 20kVAr 14% Reactor + 25kVAr,
20
+ 22.4kVAr, 480VCapacitor + 27.5kVAr, 525V Capacitor 525V Capacitor
25kVAr 7%/5.7% Reactor 25kVAr 7%/5.7% Reactor 25kVAr 14% Reactor + 30.6kVAr,
25
+ 28.1kVAr, 480V Capacitor + 33.1kVAr, 525V Capacitor 525V Capacitor
50kVAr 7%/5.7% Reactor 50kVAr 7%/5.7% Reactor 50kVAr 14% Reactor + 2 x 30.6kVAr,
50
+ 2 x 28.1kVAr, 480V Capacitor + 2 x 33.1kVAr, 525V Capacitor 525V Capacitor
75kVAr 7%/5.7% Reactor 75kVAr 7%/5.7% Reactor 75kVAr 14% Reactor + 3 x 30.6kVAr,
75
+ 3 x 28.1kVAr, 480V Capacitor + 3 x 33.1kVAr, 525V Capacitor 525V Capacitor
100kVAr 7%/5.7% Reactor 100kVAr 7%/5.7% Reactor 100kVAr 14% Reactor + 4 x 30.6kVAr,
100
+ 4 x 28.1kVAr, 480V Capacitor + 4 x 33.1kVAr, 525V Capacitor 525V Capacitor
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 287
VarPlus Logic
APFC relay
Automatic Initialization & sequence detection
Measurement of Step kVAr & THDv up to 19th
RS485 port as default feature
4 Quadrant measurement
Dual Cos phi settings for two source operation
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 288
Power Factor Correction Products
APFC Relays
No. Minimum Ordering Unit MRP
Description Reference
of Step Quantity (No.) [`]
Varlogic APFC Relays - Classic Range
RT6 , 6 step, 440V, 5A 6 1 51207 18043
RT8 , 8 step, 440V, 5A 8 1 51209 23386
RT12 , 12 step, 440V, 5A 12 1 51213 27131
VarPlus Logic APFC Relays - Advanced Range
VPL06, 6 step LCD Display , 90V - 550V 50/60Hz 1A/5A with RS485 6 1 VPL06N 40193
VPL12, 12 step LCD Display , 90V - 550V 50/60Hz 1A/5A with RS485 12 1 VPL12N 43399
Note: For ordering contactors with other coil voltages & frequencies, please contact sales representatives.
For details on non standard references, technical parameters, accessories, compatibility, stockable and non stockable status please contact Customer Care
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 289
PowerLogic™ DVR
Stabilize voltage and
maximize reliability
Reliability
Efficiency
Performance
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 290
PowerLogicTM DVR
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 291
Accusine PCS+
All in one: Harmonics, PF, Load unbalance, Flicker
Fully selectable harmonics: 2nd to 50th
Flexible CT connection: Load side/ source side
Suitable to work in Harsh environment including marine application
Parallel connection up to 99 units - any combination of models
Standards compliance / certification: (UL508, CSA 22.2 No.14) CE Certified
PCBA Protection - conformal coating on all PCBAs polution Degree 2
Heavy Oil & Gas Marine Water Wastewater Processing plants Mining Nuclear Airport HVAC Healthcare
Industry (on/off shore) plants
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 292
Accusine PCSn
Discover the new
AccuSine PCSn
Your 3-phase + neutral active harmonic filter
Heavy Retail Healthcare Hotel & Life sciences & Datacenter Light Food &
Industry space Casino University Cloud Farm Industry Beverage
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 293
Active Harmonic Filtering Solutions
AccuSine PCS+
• 3 Ph, 3 wire connection
• From 208V to 690V supply
• Parallel connection up to 99 units - any combination of models
• Harmonic cancellation spectrum from 2nd to 50th harmonic order
• Load balancing of source current
• DPF correction
• Can be used with PF capacitors as Hybrid VAR compensation (HVC) system
Accusine PCS+
Minimum Ordering Unit MRP
Description AMPS Reference
Quantity (No.) [`]
AccuSine PCS+
AccuSine PCS+ 60A 380V- 480V 50- 60Hz IP31 60 1 PCSP060D5IP31 On Request
AccuSine PCS+ 120A 380V - 480V 50- 60Hz IP31 120 1 PCSP120D5IP31 On Request
AccuSine PCS+ 200A 380V- 480V 50- 60Hz IP31 200 1 PCSP200D5IP31 On Request
AccuSine PCS+ 300A 380V- 480V 50- 60Hz IP31 300 1 PCSP300D5IP31 On Request
AccuSine PCSn
Clean up your current
Units design to work in high ambient temp up to 50 Deg C
3 Level IGBT to meet tough target requirements from Utilities
3-in-1 Harmonic Correction, PF improvement, Main current balancing
AccuSine PCSn
Minimum Ordering Unit MRP
Description AMPS Reference
Quantity (No.) [`]
AccuSine PCSn
AccuSine PCSn 30A 208-415Vac 3ph+N chassis IP00 30 1 PCSN030Y4CH00 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N chassis IP00 60 1 PCSN060Y4CH00 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N chassis IP00 expansion module 60 1 PCSN060Y4CH00E On Request
AccuSine PCSn 30A 208-415Vac 3ph+N wall mount IP20 30 1 PCSN030Y4W20 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N wall mount IP20 60 1 PCSN060Y4W20 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N wall mount IP20 expansion module 60 1 PCSN060Y4W20E On Request
AccuSine PCSn 30A 208-415Vac 3ph+N rack mount 19" 30 1 PCSN030Y4R19 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N rack mount 19" 60 1 PCSN060Y4R19 On Request
AccuSine PCSn 60A 208-415Vac 3ph+N rack mount 19" expansion module 60 1 PCSN060Y4R19E On Request
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 294
Go
with your
power factor correction
#WhatsYourBoldIdea
se.com/in
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 295
Digitize your power
factor correction
PowerLogicTM VarSet Smart
Every electrical network can benefit from power factor correction. It’s the fastest way to
save money and improve energy efficiency
An EcoStruxure™-ready VarSet Smart solution provides industry-leading diagnostics and loT con-
nectivity for superior performance monitoring and optimized maintenance.
Energy efficiency
• Lower utility bills by avoiding power factor penalties, lowering
demand charges
• Unlock extra system capacity to expand and serve additional loads
• Increase equipment performance and lifespan with improved voltage
• Reduce C02 emissions with improved power efficiency
Reliability and performance
• With smart controller, embedded environmental sensors and energy
gateway server
• Notify when problems are detected or maintenance is needed
• Self-monitoring and ready to connect to any system
Built to the highest standards Remote power factor monitoring center
• Save time and effort with easy capacitor bank configuration selection
and installation
• Tested and certified according to IEC 61439-1 & 2 and IEC 61921
• Engineered for safety and advanced performance
• Robust enclosure system with heavy-duty capacitors and detuned
* Figures based on previous customer
reactors
performance. Not a guarantee of
• Optimized for remote monitoring and preventative maintenance performance in every case.
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 296
Power Factor Correction Equipment - VarSet
Reliable Safe
Achieves Target set PF Burst proof capacitors
Reduces demand kVA Detuned Reactors- No Harmonic Amplification
Eliminates PF Penalty Minimum switching transient
Specify what exactly it means
Fuel savings in DG
Quality of construction
Compliance to and which Indian Standards
Stringent quality control measures
Best Engineering practices
Best thermal design for heat dissipation
ISO 9001 ISO 14001 IGBC Green building IEC ROHS REACH Indian Standards
ISO 50001 Gold medal
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 297
Power Factor Correction Equipment - VarSet
Incomer ACB
500 2x25kVAr + 3x50kVAr + 3x100kVAr VCLVW0C20500B6A 1200 x 800 x 2325 On Request
V C L V W 0 C 1 0 1 0 0 B 6 M
Please contact Customer care center for Stockable and Non stockable status of references.
NORMAL STOCK ITEMS W.E.F. January 25, 2022
se.com/in 298
Power Factor Correction Equipment - VarSet
se.com/in 299
Note
Note
Note
Schneider Electric India Pvt. Ltd.
Corporate Office: 9th Floor, DLF Building No. 10, Tower C, DLF Cyber City, Phase II, Gurugram 122002 Haryana
Tel.: ++91 124 6899000 Fax: ++91 124 4222036/037
Distributor