GRUNDFOS DATA BOOKLET

AP, KP
Wastwater pumps
60 Hz
Contents

General data
Performance range Page 3
Applications Page 4
Examples of application Page 4
Pump overview Page 5
Type key for AP pumps Page 5
Type key for KP pumps Page 5
Construction Page 6
Installation Page 6
Sectional drawing Page 6

Performance curves
Technical data
KP Page 7
AP12 Page 10
AP30 Page 14
AP35 Page 18
AP35B Page 22
AP50 Page 25
AP50B Page 29
AP51 Page 32
AP51 Vortex Page 36
Control box Page 40
AP80 Page 41
APG Page 47

Accessories
LC 107, LCD 107 Page 51
LC 108, LCD 108 Page 52
Level switches Page 53
Accessories for AP, KP stainless steel pumps Page 54
Accessories for cast iron AP pumps Page 55
Level controllers and accessories Page 57
Free-standing installation or portable Page 58
Installation on auto-coupling Page 58
Vertical dry installation (D) Page 58
Level controllers and accessories Page 59
Pipe dimensions Page 59

Product range
KP Page 60
AP12, AP30 Page 61
AP35, AP35B, AP50, AP50B Page 62
AP51, AP51 Vortex Page 63
AP80, APG Page 64

2
General data Wastewater pumps
AP, KP

Performance range
H H
[m] [m]
16 Drainage pumps 28 Wastewater and
sewage pumps
14
24
12
20
10
16
8
12
6 AP51
KP AP12 8
4

2 4
AP30
TM00 8603 4799

TM00 8602 4799


0 0
0 1 2 3 4 5 6 7 8 9 Q [l/s] 0 2 4 6 8 10 12 14 16 18 Q [l/s]

0 8 16 24 32 Q [m³/h] 0 20 40 60 Q [m³/h]

H H
[m] [m]
14 Wastewater and Grinder pumps
sewage pumps 50
12
40
10

8 30
APG
6
20
4
10
2 AP50
AP35
TM00 8604 4799

TM00 8605 4799


0 0
0 1 2 3 4 5 6 7 8 Q [l/s] 0 1 2 3 4 5 6 Q [l/s]

0 8 16 24 Q [m³/h] 0 5 10 15 20 Q [m³/h]

H H
[m] [m]
16 Wastewater and Sewage pumps
30
sewage pumps
14
25
12

10 20
AP50B
8 15
6 AP80
10
4
AP35B 5
2
TM01 9566 2100

TM01 7718 2100

0 0
0 1 2 3 4 5 6 7 8 Q [l/s] 0 5 10 15 20 25 30 35 40 45 50 Q [l/s]

0 8 16 24 Q [m³/h] 0 40 80 120 160 Q [m³/h]

3
General data Wastewater pumps
AP, KP

Applications
The KP and AP pumps are suitable for temporary as well For permanent installation, level controllers are avail-
as permanent free-standing installation. Furthermore able: LC for one-pump installations and LCD for two-
AP pumps are suitable for installation on an auto- pump installations.
coupling at the bottom of a pit with guide rails going to
the top.
As an option the AP80 pumps are available for dry pit
installation.
The pumps are designed for intermittent operation.
pH value for KP pumps: 4 to 9.
pH value for AP pumps: 4 to 10.
Maximum density: 1.100 kg/m3.
Maximum installation depth below water level: 10 m.

Examples of application

Vortex
AP50B
AP35B

AP80
AP30

AP50
AP12

AP35

AP51

AP51

APG
Max. liquid temperature KP
50°C 55°C 40°C 55°C 40°C 55°C 40°C 40°C 40°C 40°C 40°C
Pumping of wastewater from rivers and lakes ! ! ! ! ! ! " ! "
Pumping of drainage water and flood water ! ! ! ! ! ! ! " ! "
Pumping of surface rainwater ! ! ! ! ! ! ! ! ! "
Pumping of ditch and excavation drainage water ! ! ! ! ! ! ! !
Pumping of drainage water from garage sprinkler systems " ! " " " " ! " "
Mobile use for contractors, installers and industry ! ! ! ! ! ! ! ! "
Filling/emptying of containers ! ! ! ! ! ! ! ! !
Transfer of liquids in industry, etc. ! ! ! ! ! ! ! ! !
Pumping of effluents from tunnels, underground garages etc. ! ! ! ! ! ! ! ! !
Pumping of sewage from single and multi-family dwellings ! !
Pressurized pumping of sewage from camp sites, service areas and remote buildings !
Pressurized pumping of sewage from public buildings and small factories !
Pumping of sewage from private toilets, showers, swimming pools etc. below sewer
! ! ! ! " !
level
Pumping of wastewater from single and multi-family homes, camp sites and sports
" " " ! !
stadiums
Pumping of sewage in municipal applications ! !
Pumping of sewage from hotels, restaurants, cinemas, schools and public buildings ! !
Pumping of wastewater from underground stations and public swimming pools ! !
● = Recommended pump type
❍ = Alternative pump type

4
General data Wastewater pumps
AP, KP

Pump overview
Free passage
Pump range Impeller type Number of motor poles
[mm]
KP 10 Semi-open 2
AP12 12 Semi-open 2
AP30 30 Open single-channel 2
AP35 35 Vortex 2
AP35B 35 Vortex 2
AP50 50 Vortex 2
AP50B 50 Vortex 2
AP51 50 Single-channel 2
AP51 Vortex 51 Vortex 2
AP80 80 Single-channel 4
Cutter system with
APG grinder pumps 2
semi-open impeller

Type key for AP pumps


Example AP 30 .50 .13 A 1 .V

AP: AP pump range

12-80: Max. free passage [mm]


G: With cutter system (APG grinder pumps)

B Basic

40-80: Nominal diameter of discharge port [mm]

0.4 - 107: Power output P2/100 [W]

A: With level switch

1: Single-phase voltage supply


none or 3: Three-phase voltage supply

V: With vortex impeller

Type key for KP pumps


Example KP 150 A -1

KP: Pump range

150: 150 W motor power output


250: 250 W motor power output
350: 350 W motor power output

A: With float switch


AV: With vertical level switch
M: Without level switch

1: Single-phase voltage supply


3: Three-phase voltage supply

5
General data Wastewater pumps
AP, KP

Construction Sectional drawing


Vertical, single-stage, submersible centrifugal pumps
with horizontal or vertical discharge port designed for
free-standing installation or installation by means of an
auto-coupling guide rail system or for pit installation.
The pumps are directly connected to an asynchronous
submersible motor for
• 1 x 230 V ±10%, 60 Hz
• 3 x 230 V ±10%, 60 Hz
• 3 x 380 V ±10%, 60 Hz or
• 3 x 460 V ±10%, 60 Hz.
Enclosure class: IP 68.
Insulation class: F (155°C).

Stainless steel pumps


Single-phase pumps incorporate thermal overload
protection and require no additional motor protection.
Three-phase pumps must be connected to a motor
starter.

Cast iron pumps


APG pumps have a built-in thermal protection which
cuts off the motor in case of overload. The motor restarts
automatically.
Some three-phase pumps have a thermal switch in the
motor windings.

Installation
The pumps are suitable for free-standing installation as
well as installation on an auto-coupling guide rail
system, which is available as an accessory.
Pumps in permanent submersible installations can be
installed by means of a stationary auto-coupling at the

TM01 4260 5098


bottom of the pit. Two guide rails going to the top of the
pit ensure that the pump is positioned correctly when
lowered from the top of the pit down to the auto-
coupling and connected to the pipe system. Due to this AP80.100.21
system, the pump can easily be pulled up for service.
For free-standing installation the AP80 and APG pumps
must be fitted with a base stand, see accessories.

6
Technical data Drainage pumps
KP

KP Discharge
KP 150, KP 250 and KP 350: Rp 1¼.

Pump sleeve and housing


Single-stage, submersible, stainless steel, drainage
pump in a robust design with upwards-pointing
discharge port placed on top of the pump.
The water enters the pump through the holes of the
suction strainer preventing the passage of large solids.

TM01 7145 4099


The sturdy impeller has single curved vanes with
bevelled front edges that prevent fibres from jamming
the impeller. The guide vanes in the pump housing not
only guide the liquid but also lift sand grains into the
liquid flow and thus prevent blocking by sand.
The KP pump is designed for liquid transfer and drainage
of clean or slightly dirty wastewater with the pump The outer casing is made in one piece. The mains cable
completely or partly submerged in the liquid. and the cable of the level switch are combined in one
vulcanized and watertight plug, which is secured to the
• drainage of cellars or buildings,
socket of the hermetically sealed stator housing.
• pumping of domestic wastewater without toilet
waste, Motor
• groundwater lowering,
The motor is a single- or three-phase, asynchronous
• emptying applications, eg. in pools,
canned motor with liquid-filled rotor chamber and
tanks and vessels and
water lubricated bearings. The motor is cooled by the
• pumping applications within agriculture, dairy pumped liquid around the motor.
industry, horticulture and process industry.
Enclosure class: IP 68.
Insulation class: F.
Approvals
The motor incorporates automatic overload protection
Z-53.3-408 according to Institut für Bautechnik, Berlin. which cuts out the motor in case of overload. When it
has cooled to normal temperature, the motor will restart
Pumped liquids automatically.
Pumps without level switch or with float switch: Note: The motors for 3 x 200 V do not incorporate over-
The pump is suitable for the pumping of load protection.
• clean, non-aggressive water and
Materials
• slightly dirty (grey) wastewater.
Components Materials DIN W.-Nr. AISI
If the pump has been used for other liquids than clean Outer casing Stainless steel 1.4301 304
water, it should be flushed through with clean water Pump housing Stainless steel 1.4301 304
immediately after use. The open impeller construction Suction strainer Stainless steel 1.4301 304
ensures a free passage of solids up to a diameter of ø10 Impeller Stainless steel 1.4301 304
mm. Shaft Stainless steel 1.4057 431
Pumps with vertical level switch: Stator housing Stainless steel 1.4301 304
The pump must only be used for the pumping of clean Guide vanes Stainless steel 1.4301 304
ground water and drain water. Bearings Carbon
O-rings
NBR
Seal rings
Operating range Cables H07 RN-F
Installation depth: Max. 10 metres below liquid Performance curves Technical data
level. KP
Min. liquid temperature: 0°C.
Max. liquid temperature
at continuous operation: 50°C.
During continuous pumping the suction strainer must
always be completely covered by the liquid.
Max. liquid temperature: 70°C for periods not ex-
ceeding 2 minutes at intervals of at least 30 minutes.

7
Technical data Drainage pumps
KP

p H
[kPa] [m]
10
KP350 KP
60 Hz
9

80 KP 250
8

60 6
KP 150
5

40 4

20 2

0 0
TM01 7717 4799

0 2 4 6 8 10 12 14 Q [m³/h]

0 1 2 3 4 Q [l/s]

P1 p2 In Dimensions [mm] Weight


Pump type Voltage
[W] [W] [A] H B1 B2 L1 L2 L3 [kg]
KP 150 1 x 100 V 310 150 3.2 225 149 30 350# 400 70 6.3
KP 150 1 x 115 V 300 150 2.9 225 149 30 350# 400 70 6.3
KP 250 1 x 100 V 542 250 5.7 225 149 31 350# 400 70 7.2
KP 250 1 x 115 V 480 250 4.9 225 149 31 350# 400 70 7.2
KP 250 1 x 220 V 480 250 2.5 225 149 31 350# 400 70 7.2
KP 250 3 x 200 V 440 250 4.5 225 149 31 350# 400 70 7.2
KP 350 1 x 100 V 800 350 8.2 235 149 31 350# 410 70 8.0
KP 350 1 x 115 V 850 350 8.2 235 149 31 350# 410 70 8.0
KP 350 1 x 220 V 750 350 3.2 235 149 31 350# 410 70 8.0
KP 350 3 x 200 V 690 350 2.4 235 149 31 350# 410 70 8.0
# With vertical level switch : 250 mm.

With float switch With vertical level switch

min
. L3
min. L 2

• • •
• • • •
• •

• • • • • • •
• • • • • •
• • • •

• • •
• • •
• •
• • • •

• •
• • • • • • •
• • • • •
• • • •

• • •
• • • • • • • • •
• • •
• • •
• • • • • •
• • •
• • • •
• •
• • • • • •
• •
• • • •
• • • • • •
• • •
• • • •

• •


• • •
H

• •

• •

• •
• •
• •
• •
• •



• • • •


• •



• • • •

• •
• •

• •

• •






• •


• •
• •
• •

• •

• • • •

• • •
• •


• •
• •

• • •

• •
• •

• •

400 mm


• •
• •
• •
• • • •

min. L 1
• • • •

• •


• • •


• •

• •
• •
• •

• •
• •



• •
• • •


• •



• • •

• •




• •

• •
• •




• •



• •


• •
• •
• •

• •

• • • •

• • •

Rp 1 1 / 4
• •


• •
B2

• •

• •



• • •

• •

• •

• •
• •
• •
• • • •

• • • •

• •


• • •

• •

• • • • • • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • • • •
• • • • • • • • • • • • • • •
• • • • • •
• • • • • •
• • • • • •
• • • • • •
• • •
• • • • • • • • • • • •
• • •
• • • • • •
• • •
• • • • • •
• • •
• • • • • •
• • • • • • • • • • • • •
• • •
• • • • • • • • •
• • • • • • • • •
• • •
TM01 1109 1098

• • •
TM00 1803 1597
B1

ø 250 mm

8
Technical data Drainage pumps
KP

Installation Level switches


Pumps without level switch or with float switch can be A level switch, which gives impulses to start/stop
used in vertical position with the discharge port upper- between two levels of liquid, is connected to pumps
most or in horizontal or tilted position with the intended for automatic operation. This type of installa-
discharge port as the highest point of the pump. tion requires a non-return valve in the discharge pipe or
in the pump. The pumps are available with two different
types of level switches.
Min. liquid level: – manual operation: 14 mm.
– automatic operation: See below.

TM00 1548 0493


Pumps with float switch:
A clamp on the handle of the pump holds the cable of the
level switch. The difference in level between start and
Pumps with vertical level switch must be used in vertical stop can be adjusted by changing the free cable length
position. between the handle of the pump and the level switch.
Dimensions for KP 350 are marked with "#".
Float switch
Max.Max.
150 mm
150mm
TM00 1492 4697

Start

••••••••••••••••••••••••
•••••••••
••••••••••••••••••••••••••••••
•••••••••••••••••••••
225 mm
225mm
••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••

The KP pump is well suited for permanent installation.


Stop

TM00 1552 2599


100 mm
100mm
110 mm#

Pumps with vertical level switch:


For pumps with vertical level switch, the difference in
level between start and stop is not adjustable.
Dimensions for KP 350 are marked with "#".

Vertical level switch

Start
8080
mmmm
Stop
TM01 1108 3297

100 mm
100mm
110 mm#

9
Technical data AP12

AP12 The stainless steel pump housing is fitted with an


internal riser pipe ensuring high efficiency. The riser pipe
has a number of holes which enable efficient cooling of
the motor during operation. The cable entry is of the
socket and plug connection type, which makes quick and
easy dismantling possible.

Discharge port
All AP12 pumps have a threaded vertical discharge
port.
AP12.40: Rp 1½.

TM00 5738 0895


AP12.50: Rp 2.

Shaft and bearings


The AP12 pump is a single-stage submersible pump The shaft is made of stainless steel and rotates in main-
designed for the pumping of drainage water. The pump tenance-free prelubricated ball bearings.
is suitable for the following applications
• ground water lowering,
Impeller
• pumping in drainage pits, The stainless steel impeller is a semi-open impeller with
L-shaped blades and a clearance of 12 mm. The blades
• pumping in surface water pits with inflow from roof
are curved backwards to reduce any harmful effect from
gutters, shafts, tunnels, etc.,
solid particles and to reduce the power consumption.
• emptying of ponds, tanks, etc. and
• maximum particle size: 12 mm.

TM00 5477 4000


Approvals
PA-I no. 4104 VDE.

Automatic operation
The pump is available for automatic as well as manual Shaft seal
operation and can be installed in a permanent installa-
The shaft seal is a combination of a mechanical shaft
tion or used as a portable pump. The pump is available:
seal of the bellows type and a lip seal with 60 ml oil
• with level switch fitted for automatic ON/OFF opera- between them. The mechanical shaft seal of AP12 pumps
tion between two liquid levels has silicone carbide seal faces.
(single-phase pumps);
• with separate level switch and control box for auto- Motor cable
matic ON/OFF operation between two liquid levels
(three-phase pumps); Standard pumps 10 m: H07RNF.
• without level switch for manual ON/OFF operation.
Materials
Pumps fitted with level switches can also be used for
Description Materials DIN W.-Nr. AISI
manual ON/OFF operation. In this case the level switch
Pump housing Stainless steel 1.4301 304
must be secured in an upwards-pointing position.
Riser pipe Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Pump sleeve and housing Pump sleeve Stainless steel 1.4401 316
The stainless steel pump sleeve is made in one piece and Shaft Stainless steel 1.4305
equipped with an insulated carrying handle. The suction Bearings Heavy-duty prelubricated ball bearings
strainer is clipped on to the pump housing and can easily O-rings NBR rubber
be removed for maintenance. The strainer not only Screws Stainless steel 1.4301 304
prevents the passage of large solids but also ensures a Oil Shell Ondina 15, non-toxic
slow flow into the pump. As a result, most impurities
will be deposited outside the pump.

10
Performance curves AP12

p H
[kPa] [m] AP12
160
16 .50 60 Hz
.11
.50 .1 ISO 9906 +/- 10%
.11
14
.40 .3
.0
.40 8.1
.4 .08.3
0.
120 06
12 .1
.4
0.
06
10
.3
.40
.04
80 8

40 4

0 0
0 5 10 15 20 25 30 35 Q [m³/h]

0 2 4 6 8 10 Q [l/s]
P1 P1
[hp] [kW]
2.0 .50.11.1
2.4
1.6
.50.11.3
.40.08.1
1.6 1.2 .40.08.3
.40.06.3
.40.06.1
0.8
0.8
.40.04.1
0.4

0.0 0.0
0 5 10 15 20 25 30 35 Q [m³/h]
TM00 7213 4799

11
Technical data AP12

B
S
A

TM00 5523 0995

P1 p2 Dimensions [mm]
In I start Weight
Pump type Voltage Cos ϕ ---------
[kW] [kW] [A] In A B S [kg]

AP12.40.04.1 1 x 220 - 230 V 0.8 0.4 3.7 0.99 6.0 321 216 Rp 1½ 10.0 - 10.8
AP12.40.04.A1 1 x 220 - 230 V 0.8 0.4 3.7 0.99 6.0 321 216 Rp 1½ 10.0 - 10.8
AP12.40.04.3 3 x 200 - 220 V 0.8 0.4 2.4 0.91 6.0 321 216 Rp 1½ 9.7 - 12.0
AP12.40.04.A3 3 x 200 - 220 V 0.8 0.4 2.4 0.91 6.0 321 216 Rp 1½ 9.7 - 12.0
AP12.40.04.3 3 x 380 - 400 V 0.8 0.4 1.1 0.83 6.0 321 216 Rp 1½ 9.7 - 12.0
AP12.40.04.A3 3 x 380 - 400 V 0.8 0.4 1.1 0.83 6.0 321 216 Rp 1½ 9.7 - 12.0
AP12.40.06.1 1 x 220 - 230 V 1.0 0.6 4.4 0.99 3.8 321 216 Rp 1½ 10.8 - 11.6
AP12.40.06.A1 1 x 220 - 230 V 1.0 0.6 4.4 0.99 3.8 321 216 Rp 1½ 10.8 - 11.6
AP12.40.06.3 3 x 200 - 220 V 1.0 0.6 3.2 0.91 6.0 321 216 Rp 1½ 10.7 - 13.0
AP12.40.06.A3 3 x 200 - 220 V 1.0 0.6 3.2 0.91 6.0 321 216 Rp 1½ 10.7 - 13.0
AP12.40.06.3 3 x 380 - 400 V 0.9 0.6 1.5 0.83 6.0 321 216 Rp 1½ 10.7 - 13.0
AP12.40.06.A3 3 x 380 - 400 V 0.9 0.6 1.5 0.83 6.0 321 216 Rp 1½ 10.7 - 13.0
AP12.40.08.1 1 x 220 - 230 V 1.3 0.8 5.9 0.99 3.8 346 216 Rp 1½ 12.4 - 13.2
AP12.40.08.A1 1 x 220 - 230 V 1.3 0.8 5.9 0.99 3.8 346 216 Rp 1½ 12.4 - 13.2
AP12.40.08.3 3 x 200 - 220 V 1.2 0.8 3.9 0.91 6.0 346 216 Rp 1½ 12.0 - 14.3
AP12.40.08.A3 3 x 200 - 220 V 1.2 0.8 3.9 0.91 6.0 346 216 Rp 1½ 12.0 - 14.3
AP12.40.08.3 3 x 380 - 440 V 1.2 0.8 1.8 0.87 6.0 346 216 Rp 1½ 12.0 - 14.3
AP12.40.08.A3 3 x 380 - 440 V 1.2 0.8 1.8 0.87 6.0 346 216 Rp 1½ 12.0 - 14.3
AP12.50.11.1 1 x 220 - 230 V 1.8 1.1 9.0 0.98 6.0 357 241 Rp 2 14.9 - 15.7
AP12.50.11.A1 1 x 220 - 230 V 1.8 1.1 9.0 0.98 6.0 357 241 Rp 2 14.9 - 15.7
AP12.50.11.3 3 x 200 - 220 V 1.6 1.1 5.9 0.85 6.0 357 241 Rp 2 15.6 - 17.9
AP12.50.11.A3 3 x 200 - 220 V 1.6 1.1 5.9 0.85 6.0 357 241 Rp 2 15.6 - 17.9
AP12.50.11.3 3 x 380 - 440 V 1.8 1.1 2.7 0.88 6.0 357 241 Rp 2 15.6 - 17.9
AP12.50.11.A3 3 x 380 - 440 V 1.8 1.1 2.7 0.88 6.0 357 241 Rp 2 15.6 - 17.9

12
Technical data AP12

AP12 installations

TM00 5539 0995


TM00 5538 0995

min. ø500 min. ø800

13
Technical data AP30

AP30 Impeller
The impeller is a vortex impeller in cast iron GG 25 with
a free passage of 30 mm in the pump housing. Cast iron
is chosen as it is resistant towards mechanically
wearing particles.

TM01 7174 4099

TM01 2617 2098


The pumps are used for pumping wastewater, sludge-
containing water, ground water and surface water in
places such as
• holiday homes,
Shaft seal
• single-family houses, Combination of mechanical shaft seal and lip seal.
• blocks of flats, The primary shaft seal have silicon carbide/silicon
• public buildings, carbide seal faces.
The secondary shaft seal is a lip seal. The chamber
• factories,
between the shaft seals is filled with oil.
• garages,
Standard pumps: 0.01 litre
• underground car parks and
• car wash areas. Motor cable
Applications as under AP12, but where a larger impeller
Standard pumps 10 m: H07RNF.
clearance is required.

Pump and stator housing Materials


AISI/
The pump housing and the stator housing are made of Description Materials DIN W.-Nr.
ASTM
cast iron. Stator housing Cast iron GG 25 0.6025 ASTM 35B
Pump housing Cast iron GG 25 0.6025 ASTM 35B
The stator housing is dry, i.e. not oil-filled.
Neck ring Bronze
Impeller Cast iron GG 25 0.6025 ASTM 35B
Discharge Wear plate Cast iron GG 25 0.6025 ASTM 35B
All AP30 pumps have a horizontal R 2 discharge port for Shaft Stainless steel 1.4104 AISI 430F
threaded connection. Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304

Shaft and bearings Oil Shell Ondina 15, non-toxic

The shaft is made of stainless steel and rotates in main- Control box
tenance-free prelubricated ball bearings.
Further information about control box, float switch, and
level controller, see page 40.

14
Performance curves AP30

p H
[kPa] [m]
12
AP30.50.
60 Hz
14 ISO 2548 Annex B
11 .3
. V
100
10

9
13
.1
80 .V
8

7
09
.3
.V
60 6

40 4

20 2

1
09.1.V
0 0
0 5 10 15 20 25 30 35 Q [m³/h]

0 2 4 6 8 10 Q [l/s]
P1 P1
[hp] [kW]
2.0
14.3.V
2.4
13.1.V
1.6

1.6 1.2 09.3.V

0.8 09.1.V
0.8
0.4

0.0 0.0
0 5 10 15 20 25 30 35 Q [m³/h]
TM00 7215 4799

15
Technical data AP30

S
A
E

C
D

TM01 2550 2098


B

Elbow is an accessory

P1 P2 n Dimensions [mm]
In I start Weight
Pump type Voltage Cos ϕ ---------
[kW] [kW] [min-1] [A] In A B C D E S [kg]

AP30.50.09.1.V 1 x 230 V 1.2 0.9 3450 5.4 0.97 3.4 431 312 101 51 175 R2 26 - 27
AP30.50.09.A1.V 1 x 230 V 1.2 0.9 3450 5.4 0.97 3.4 431 312 101 51 175 R2 26 - 27
AP30.50.09.3.V 3 x 230 V 1.2 0.9 3450 4.0 0.79 6.0 431 312 101 51 175 R2 25
AP30.50.09.3.V 3 x 380 V 1.2 0.9 3450 2.3 0.79 6.0 431 312 101 51 175 R2 25
AP30.50.09.3.V 3 x 460 V 1.2 0.9 3450 1.9 0.79 6.0 431 312 101 51 175 R2 25
AP30.50.13.1.V 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 431 312 101 51 175 R2 26 - 27
AP30.50.13.A1.V 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 431 312 101 51 175 R2 26 - 27
AP30.50.14.3.V 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 431 312 101 51 175 R2 25
AP30.50.14.3.V 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 431 312 101 51 175 R2 25
AP30.50.14.3.V 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 431 312 101 51 175 R2 25

16
Technical data AP30

AP30 installations

A
B
C
D
F

E
S




‹ ‹

‹ ‹
‹ ‹
‹ ‹

‹ ‹
‹ ‹ ‹ ‹
Z

‹ ‹
‹ ‹
‹ ‹

‹ ‹ ‹ ‹

‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
U

‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
J

‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹

I
G
M M
K L

TM01 2552 2098


TM01 2551 2098

P R P
N O

One-pump installation on auto-coupling


Pump type A B C D E F G I J K L M N O P S T U Z
AP30.50.09.1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.09.A1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.09.3.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.13.1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.13.A1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.14.3.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295

Two-pump installation on auto-coupling


Pump type A B C D E F G I J K L M N O P R S T U Z
AP30.50.09.1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.09.A1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.09.3.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.13.1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.13.A1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.14.3.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295

17
Technical data AP35

AP35 The stainless steel pump housing is fitted with an


internal riser pipe ensuring high efficiency. The riser pipe
has a number of holes which enable efficient cooling of
the motor during operation. The cable entry is of the
socket and plug connection type, which makes quick and
easy dismantling possible.

Discharge port
All AP35 pumps have a threaded vertical discharge port:
Rp 1½.

TM00 5739 1195


Shaft and bearings
The shaft is made of stainless steel and rotates in main-
The AP35 pump is a single-stage submersible pump tenance-free prelubricated ball bearings.
designed for the pumping of drainage water and
effluent. Impeller
The pump is suitable for the following applications
The stainless steel impeller is a Vortex impeller with
• ground water lowering, L-shaped blades and a clearance of 35 mm (in the pump
• pumping in drainage pits, housing). The blades are curved backwards to reduce any
harmful effect from solid particles and to reduce the
• pumping in surface water pits with inflow from roof
power consumption.
gutters, shafts, tunnels, etc.,
• emptying of ponds, tanks, etc.,
• pumping of fibre-containing wastewater from laun-

TM00 5478 4000


dries and industries and
• pumping of domestic wastewater without discharge
from water closets.

Approvals
Shaft seal
PA-I no. 4104 VDE.
The shaft seal is a combination of a mechanical shaft
seal of the bellows type and a lip seal with 60 ml oil
Automatic operation between them. The shaft seal has silicon carbide seal
The pump is available for automatic as well as manual faces.
operation and can be installed in a permanent installa-
tion or used as a portable pump. The pump is available: Motor cable
• with level switch fitted for automatic ON/OFF opera- Standard pumps 10 m: H07RNF.
tion between two liquid levels
(single-phase pumps);
Materials
• with separate level switch and control box for auto-
matic ON/OFF operation between two liquid levels Description Materials DIN W.-Nr. AISI
(three-phase pumps); Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
• without level switch for manual ON/OFF operation.
Impeller Stainless steel 1.4301 304
Pumps fitted with level switches can also be used for Pump sleeve Stainless steel 1.4401 316
manual ON/OFF operation. In this case the level switch Shaft Stainless steel 1.4305
must be secured in an upwards-pointing position. Bearings Heavy-duty prelubricated ball bearings
O-rings NBR rubber
Pump sleeve and housing Screws Stainless steel 1.4301 304
Cables Neoprene
The stainless steel pump sleeve is made in one piece and Oil Shell Ondina 15, non-toxic
equipped with an insulated carrying handle. The suction
strainer is clipped on to the pump housing and can easily
be removed for maintenance.
The strainer not only prevents the passage of large solids
but also ensures a slow flow into the pump.

18
Performance curves AP35

p H
[kPa] [m]
13
AP35.40.
60 Hz
08

120
.1

12 ISO 9906 Annex A


.V
06

11
.1
.V

100 06
10
.3
.V
9

80 8
08
.3
7 .V

60 6

40 4

20 2

0 0
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

0 1 2 3 4 5 6 Q [l/s]
P1 P1
[hp] [kW] 08.1.V

08.3.V
1.2 06.1.V
1.5
1.0

0.8
1.0
.V
0.6 06.3

0.5 0.4

0.2

0.0 0.0
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]
TM00 7220 4500

TM00 7220 4799

19
Technical data AP35

B
S
A

TM00 5524 0995

P1 P2 Dimensions [mm]
In I start Weight
Pump type Voltage Cos ϕ ---------
[kW] [kW] [A] In A B S [kg]

AP35.40.06.1.V 1 x 220 - 230 V 1.2 0.7 3.9 0.97 6.0 376 216 Rp 1½ 11.2 - 12.0
AP35.40.06.A1.V 1 x 220 - 230 V 1.2 0.7 3.9 0.97 6.0 376 216 Rp 1½ 11.2 - 12.0
AP35.40.06.3.V 3 x 200 - 220 V 1.1 0.6 3.2 0.91 6.0 376 216 Rp 1½ 11.1 - 13.4
AP35.40.06.A3.V 3 x 200 - 220 V 1.1 0.6 3.2 0.91 6.0 376 216 Rp 1½ 11.1 - 13.4
AP35.40.06.3.V 3 x 380 - 400 V 1.1 0.7 1.4 0.86 6.0 376 216 Rp 1½ 11.1 - 13.4
AP35.40.06.A3.V 3 x 380 - 400 V 1.1 0.7 1.4 0.86 6.0 376 216 Rp 1½ 11.1 - 13.4
AP35.40.08.1.V 1 x 220 - 230 V 1.3 0.9 5.3 0.98 6.0 410 216 Rp 1½ 12.5 - 13.3
AP35.40.08.A1.V 1 x 220 - 230 V 1.3 0.9 5.3 0.98 6.0 410 216 Rp 1½ 12.5 - 13.3
AP35.40.08.3.V 3 x 200 - 220 V 1.1 0.7 3.6 0.85 4.8 410 216 Rp 1½ 12.1 - 14.4
AP35.40.08.A3.V 3 x 200 - 220 V 1.1 0.7 3.6 0.85 4.8 410 216 Rp 1½ 12.1 - 14.4
AP35.40.08.3.V 3 x 380 - 400 V 1.1 0.7 2.0 0.86 5.2 410 216 Rp 1½ 12.1 - 14.4
AP35.40.08.A3.V 3 x 380 - 400 V 1.1 0.7 2.0 0.86 5.2 410 216 Rp 1½ 12.1 - 14.4

20
Technical data AP35

AP35 installations



• • • •

• • • • •
• •
• • • •
• • • •
• • • •
• • • • •
• • • • • •
• • •
• • • • • • •
• • • • • •
• • • • •
• • • •
• • • •
• • • • • •
• • •
• • •
• • •
• • • • • •
• • • • • •
• • • • • • •
• • • • • • • •
• • • •
• • • • • • • • • •
• • • • •
• • • • • •
• • • • • • • • • • • •
• • • • • •
• • • • • • •
• • • • • •
• • • • • •
• • • •
• • • • •
• • • • •
• • • • •
• • • •
• • • •

TM00 5936 3898


TM00 5935 3898

min. ø500 min. ø800

21
Technical data AP35B

AP35B Discharge port


All AP35B pumps have a threaded horizontal discharge
port: Rp 2.

Shaft and bearings


The shaft is made of stainless steel and rotates in main-
tenance-free prelubricated ball bearings.

Impeller

TM01 4187 4998


The stainless steel impeller is a Vortex impeller with
L-shaped blades and a clearance of 35 mm (in the pump
housing). The blades are curved backwards to reduce any
The AP35B pump is a single-stage submersible pump harmful effect from solid particles and to reduce the
designed for pumping effluent. power consumption. The impeller has a protective cap to
prevent the deposits of long-fibred material.
The pump is suitable for:
• groundwater lowering,

TM00 5478 4000


• pumping in drainage pits,
• pumping in surface water pits with inflow from roof
gutters, shafts, tunnels, etc.,
• emptying of ponds, tanks, etc.,
• pumping of fibre-containing effluent from laundries
and industries, Shaft seal
• pumping of domestic effluent from septic tanks and The shaft seal is a combination of a mechanical shaft
sludge treating systems, seal of the bellows type and a lip seal with 80 ml oil
• pumping of domestic effluent without discharge between them. The shaft seal has silicon carbide seal
from water closets. faces.

Automatic operation Materials


The pump is available for automatic as well as manual DIN
Description Materials AISI
W.-Nr.
operation and can be installed in a permanent installa-
Pump housing Stainless steel 1.4301 304
tion or used as a portable pump.
Impeller Stainless steel 1.4301 304
The pump is available: Washer Stainless steel 1.4301 304
Protective cap Novolen 2360 Kx
• with level switch fitted for automatic ON/OFF opera-
Parts in contact with liquid:
tion between two liquid levels Motor unit complete
Stainless steel
1.4401 316
(single-phase pumps); Shaft with rotor Stainless steel/silumin 1.4305
• without level switch for manual ON/OFF operation. Motor cable Neoprene
O-rings NBR rubber
Pumps fitted with level switches can also be used for
Spring Stainless steel 1.4310
manual ON/OFF operation. In this case the level switch
Pump inlet Stainless steel 1.4301 304
must be secured in an upwards-pointing position.
Base Polycarbonate
Oil Shell Ondina 15, non-toxic
Pump housing
Pump housing with an outstanding design for submers-
ible wastewater pumps resulting in a high head.
The pump housing is made of a steel tube with a smooth
surface and a hydraulically correct shape ensuring free
passage of particles.
Base, pump inlet and pump housing are fastened to the
motor by means of 4 springs enabling quick and easy
dismantling.

22
Technical data AP35B

p H
[kPa] [m] AP35B
60 Hz
140 14
ISO 9906 Annex A

120 12

100 10

80 8

A
60 6
S
40 4

TM01 9219 1500


20 2 AP35B.50.08.1
AP35B.50.06.1

D
0 0
0 5 10 15 20 Q [m³/h]

0 1 2 3 4 5 6 Q [l/s]
P1 P1
[hp] [kW]
1.6
2.0 AP35B.50.08.1
AP35B.50.06.1
1.2
1.5

1.0 0.8
TM01 3581 4498

0.5 0.4

0.0 0.0
0 5 10 15 20 Q [m³/h]

P1 Dimensions [mm]
In I start Weight
Pump type Voltage Cos ϕ ---------
[kW] [A] In A C D S [kg]

AP35B.50.06.1.V 1 x 220-230 V 1.29 5.91 0.99 3.05 443 116 73 R2 8.5


AP35B.50.06.A1.V 1 x 220-230 V 1.29 5.91 0.99 3.05 443 116 73 R2 8.5
AP35B.50.06.3.V 3 x 200-220 V 1.21 3.71 0.94 4.39 443 116 73 R2 7.5
AP35B.50.08.1.V 1 x 220-230 V 1.47 6.74 0.99 3.59 468 116 73 R2 10.1
AP35B.50.08.A1.V 1 x 220-230 V 1.47 6.74 0.99 3.59 468 116 73 R2 10.1
AP35B.50.08.3.V 3 x 200-220 V 1.48 4.5 0.94 4.87 468 116 73 R2 8.5

23
Technical data AP35B

AP35B installations

A B
C D
F







• •
• •
• • •
J

• • • • • •
• • •
• •
• •
• •
Z


• • • • • •
• •
• •
• • • •

• •• •
• •
• • • •
• • • • • •

• • • • • • • • •
• • •
• • • • • • •
• • • • •
• • • • • • • • • •
• •
U

• • • •
• • • •
• • • • • • • •
• • • • • • • • • •
• •
• • • • • • •
• • • • •• • • •
• • • • •
• • • •
• • • • • • • • •
• • • • • •
• •
• • • • • •
• • •
• • • • • • • • • •
• • •
• •
• • • • • • • • •
• • •
• • • •
• • • •
• • • • • • •
• •
• • •

I
G
M M
K L
TM01 3593 4498

TM01 3593 4498


N O P R P

One-pump installation on auto-coupling


Dimensions [mm]
Pump type
A B C D E F G I J K L M N O P R S T U Z
AP35B.50.06.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP35B.50.06.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP35B.50.06.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP35B.50.08.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP35B.50.08.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP35B.50.08.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261

Two-pump installation on auto-coupling


Dimensions [mm]
Pump type
A B C D E F G I J K L M N O P R S T U Z
AP35B.50.06.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP35B.50.06.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP35B.50.06.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP35B.50.08.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP35B.50.08.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP35B.50.08.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261

24
Technical data AP50

AP50 The stainless steel pump housing is fitted with an


internal riser pipe ensuring high efficiency. The riser pipe
has a number of holes which enable efficient cooling of
the motor during operation. The cable entry is of the
socket and plug connection type, which makes quick and
easy dismantling possible.

Discharge port
All AP50 pumps have a threaded vertical discharge port:

TM00 5740 1495


Rp 2.

Shaft and bearings


The shaft is made of stainless steel and rotates in main-
The AP50 pump is a single-stage submersible pump tenance-free prelubricated ball bearings.
designed for the pumping of effluent and sewage. The
pump is suitable for the following applications
Impeller
• ground water lowering,
The stainless steel impeller is a Vortex impeller with
• pumping in drainage pits, L-shaped blades and a clearance of 50 mm (in the pump
• pumping in surface water pits with inflow from roof housing). The blades are curved backwards to reduce any
gutters, shafts, tunnels, etc., harmful effect from solid particles and to reduce the
• emptying of ponds, tanks, etc., power consumption. The impeller has a protective cap to
prevent the deposits of long-fibred material.
• pumping of fibre-containing wastewater from laun-
dries and industries,
• pumping of domestic wastewater from septic tanks
and sludge treating systems and

TM00 5477 4000


• pumping of domestic wastewater with/without dis-
charge from water closets.

Approvals
PA-I no. 4104 and VDE. Shaft seal
Automatic operation The shaft seal is a combination of a mechanical shaft
seal of the bellows type and a lip seal with 60 ml oil
The pump is available for automatic as well as manual between them. The shaft seal has silicon carbide seal
operation and can be installed in a permanent installa- faces.
tion or used as a portable pump. The pump is available:
• with level switch fitted for automatic ON/OFF opera- Motor cable
tion between two liquid levels
(single-phase pumps); Standard pumps 10 m: H07RNF.
• with separate level switch and control box for auto-
matic ON/OFF operation between two liquid levels Materials
(three-phase pumps); Description Materials DIN W.-Nr. AISI
• without level switch for manual ON/OFF operation Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
Pumps fitted with level switches can also be used for
Impeller Stainless steel 1.4301 304
manual ON/OFF operation. In this case the level switch
Pump sleeve Stainless steel 1.4401 316
must be secured in an upwards-pointing position.
Shaft Stainless steel 1.4305
Bearings Heavy-duty prelubricated ball bearings
Pump sleeve and housing O-rings NBR rubber
Screws Stainless steel 1.4301 304
The stainless steel pump sleeve is made in one piece and
Cables Neoprene
equipped with an insulated carrying handle.
Oil Shell Ondina 15, non-toxic
The suction strainer is clipped on to the pump housing
and can easily be removed for maintenance. The strainer
not only prevents the passage of large solids but also
ensures a slow flow into the pump.

25
Performance curves AP50

p H
[kPa] [m]
13
AP50.50.
60 Hz
120
12 ISO 9906 Annex A

11

100
10

80 8

60 6

5
08
08 .1.
.3 V
40 4 .V 11
.1.
11 V
3 .3.
V

20 2

0 0
0 4 8 12 16 20 24 28 32 Q [m³/h]

0 2 4 6 8 10 Q [l/s]
P1 P1
[hp] [kW]
2.0
11.V
2.4
1.6
08.V

1.6 1.2

0.8
0.8
0.4

0.0 0.0
0 4 8 12 16 20 24 28 32 Q [m³/h]
TM00 7218 4500

TM00 7218 4199

26
Technical data AP50

B
S
A

TM00 5524 0995

P1 P2 Dimensions [mm]
In I start Weight
Pump type Voltage Cos ϕ ---------
[kW] [kW] [A] In A B S [kg]

AP50.50.08.1.V 1 x 220 - 230 V 1.4 1.0 6.3 0.98 6.0 436 241 Rp 2 14.9 - 15.7
AP50.50.08.A1.V 1 x 220 - 230 V 1.4 1.0 6.3 0.98 6.0 436 241 Rp 2 14.9 - 15.7
AP50.50.08.3.V 3 x 200 - 220 V 1.4 0.9 4.0 0.85 6.0 436 241 Rp 2 14.2 - 16.5
AP50.50.08.A3.V 3 x 200 - 220 V 1.4 0.9 4.0 0.85 6.0 436 241 Rp 2 14.2 - 16.5
AP50.50.08.3.V 3 x 380 - 440 V 1.4 1.0 2.1 0.85 6.0 436 241 Rp 2 14.2 - 16.5
AP50.50.08.A3.V 3 x 380 - 440 V 1.4 1.0 2.1 0.85 6.0 436 241 Rp 2 14.2 - 16.5
AP50.50.11.1.V 1 x 220 - 230 V 1.8 1.2 8.4 0.98 6.0 436 241 Rp 2 14.9 - 15.7
AP50.50.11.A1.V 1 x 220 - 230 V 1.8 1.2 8.4 0.98 6.0 436 241 Rp 2 14.9 - 15.7
AP50.50.11.3.V 3 x 200 - 220 V 1.6 1.2 6.0 0.85 2.9 436 241 Rp 2 15.6 - 17.9
AP50.50.11.A3.V 3 x 200 - 220 V 1.6 1.2 6.0 0.85 2.9 436 241 Rp 2 15.6 - 17.9
AP50.50.11.3.V 3 x 380 - 440 V 1.6 1.6 3.0 0.88 4.9 436 241 Rp 2 15.6 - 17.9
AP50.50.11.A3.V 3 x 380 - 440 V 1.6 1.6 3.0 0.88 4.9 436 241 Rp 2 15.6 - 17.9

27
Technical data AP50

AP50 installations


• •
• •
• •
• •
• • • • • • • •
• • • • •
• • • • • • • •

• •
• • •
• • • •
• •
• • • •
• • • •
• • • • • • • • •
• • • • • • •
• • • • • • •
• • • • •
• • • • •
• • • • •
• •
• • •
• • • • •
• • • • • • • •
• • • • • •
• • • • • • • • •
• • • • •
• • •
• • • •
• • • • • •
• • • • •
• • • • • • •
• • • • • • • •
• • • • • • • • •
• • • • • • • • • •
• • • • • • • • • •
• • • • •
• • •
TM00 5935 3898

TM00 5936 3898


min. ø500 min. ø800

28
Technical data AP50B

AP50B Discharge port


All AP50B pumps have a threaded horizontal discharge
port: R 2.

Shaft and bearings


The shaft is made of stainless steel and rotates in main-
tenance-free prelubricated ball bearings.

Impeller

TM01 4188 4998


The stainless steel impeller is a Vortex impeller with
L-shaped blades and a clearance of 50 mm (in the pump
housing). The blades are curved backwards to reduce any
The AP50B pump is a single-stage submersible pump harmful effect from solid particles and to reduce the
designed for the pumping effluent. power consumption. The impeller has a protective cap to
prevent the deposits of long-fibred material.
The pump is suitable for:
• groundwater lowering,
• pumping in drainage pits,

TM00 5477 4000


• pumping in surface water pits with inflow from roof
gutters, shafts, tunnels, etc.,
• emptying of ponds, tanks, etc.,
• pumping of fibre-containing effluent from laundries
and industries, Shaft seal
• pumping of domestic effluent from septic tanks and
The shaft seal is a combination of a mechanical shaft
sludge treating systems,
seal of the bellows type and a lip seal with 80 ml oil
• pumping of domestic effluent without discharge between them. The shaft seal has silicon carbide seal
from water closets. faces.

Automatic operation Materials


The pump is available for automatic as well as manual DIN
Description Materials AISI
operation and can be installed in a permanent installa- W.-Nr.
tion or used as a portable pump. Pump housing Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
The pump is available:
Washer Stainless steel 1.4301 304
• with level switch fitted for automatic ON/OFF opera- Protective cap Novolen 2360 Kx
tion between two liquid levels Motor unit complete
Parts in contact with liquid:
1.4305 316
(single-phase pumps); Stainless steel
Shaft with rotor Stainless steel/silumin 1.4401
• without level switch for manual ON/OFF operation.
Motor cable Neoprene
Pumps fitted with level switches can also be used for O-rings NBR rubber
manual ON/OFF operation. In this case the level switch Spring Stainless steel 1.4310
must be secured in an upwards-pointing position. Pump inlet Stainless steel 1.4301 304
Base Polycarbonate
Pump housing Oil Shell Ondina 15, non-toxic

Pump housing with an outstanding design for submers-


ible wastewater pumps resulting in a high head.
The pump housing is made of a steel tube with a smooth
surface and a hydraulically correct shape ensuring free
passage of particles.
Base, pump inlet and pump housing are fastened to the
motor by means of 4 springs enabling quick and easy
dismantling.

29
Technical data AP50B

p H
[kPa] [m] AP50B
60 Hz
160 16 ISO 9906 Annex A

140 14

120 12
AP
100 10 50
B.
50
A5 .1
AP 0B 5.
.5 3
80 8 50 0.

A
B. 11
50 .1
AP .1
1.
60 6 AP 0B
50
5
.5
B. 0.08
3
S
50
.08 .1
.3
40 4

TM01 9219 1500


20 2

D
0 0
0 5 10 15 20 25 Q [m³/h]

0 1 2 3 4 5 6 7 8 Q [l/s]
P1 P1
[hp] [kW]
2.0 50.15.3
2.5 AP50B. AP50B.50.11.1
1.6
2.0 .1 AP50B.50.11.3
.50.08
AP50B
1.2 .3
1.5 .50.08
AP50B
1.0 0.8
TM01 3583 4498

0.5 0.4
TM01 3583 3100

0.0 0.0
0 5 10 15 20 25 Q [m³/h]

P1 P2 Dimensions [mm]
In I start Weight
Pump type Voltage Cos ϕ ---------
[kW] [kW] [A] In A C D S [kg]

AP50B.50.08.1.V 1 x 220-230 V 1.4 0.8 6.4 0.99 3.78 468 116 73 R2 10.1
AP50B.50.08.A1.V 1 x 220-230 V 1.4 0.8 6.4 0.99 3.78 468 116 73 R2 10.1
AP50B.50.08.3.V 3 x 200-220 V 1.31 0.8 4.12 0.92 5.32 468 116 73 R2 8.5
AP50B.50.11.1.V 1 x 220-230 V 1.8 1.1 8.42 0.97 3.56 468 116 73 R2 10.1
AP50B.50.11.A1.V 1 x 220-230 V 1.8 1.1 8.42 0.97 3.56 468 116 73 R2 10.1
AP50B.50.11.3.V 3 x 200-220 V 1.73 1.1 5.41 0.93 5.91 468 116 73 R2 9.8
AP50B.50.15.3.V 3 x 200-220 V 1.98 1.5 6.25 0.91 6.4 468 116 73 R2 10.0

30
Technical data AP50B

AP50B installations

A B
C D
F







• •
• •
• • •
J

• • • • • •
• • •
• •
• •
• •
Z


• • • • • •
• •
• •
• • • •

• •• •
• •
• • • •
• • • • • •

• • • • • • • • •
• • •
• • • • • • •
• • • • •
• • • • • • • • • •
• •
U

• • • •
• • • •
• • • • • • • •
• • • • • • • • • •
• •
• • • • • • •
• • • • •• • • •
• • • • •
• • • •
• • • • • • • • •
• • • • • •
• •
• • • • • •
• • •
• • • • • • • • • •
• • •
• •
• • • • • • • • •
• • •
• • • •
• • • •
• • • • • • •
• •
• • •

I
G
M M
K L
TM01 3593 4498

TM01 3593 4498


N O P R P

One-pump installation on auto-coupling


Dimensions [mm]
Pump type
A B C D E F G I J K L M N O P R S T U Z
AP50B.50.08.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP50B.50.08.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP50B.50.08.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP50B.50.11.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP50B.50.11.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP50B.50.11.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261
AP50B.50.15.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R2 ¾" 130 261

Two-pump installation on auto-coupling


Dimensions [mm]
Pump type
A B C D E F G I J K L M N O P R S T U Z
AP50B.50.08.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP50B.50.08.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP50B.50.08.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP50B.50.11.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP50B.50.11.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP50B.50.11.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261
AP50B.50.15.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R2 ¾" 130 261

31
Technical data AP51

AP51 with single-channel impeller Impeller


The impeller is a closed single-channel cast iron impeller
with a clearance of 51 mm. Cast iron is chosen as it is
resistant towards mechanically wearing particles.

TM00 3566 5093


TM01 7174 4099
The inlet side of the pump housing is fitted with a
replaceable neck ring.
The pumps are used for pumping wastewater, sludge-
containing water, considerable quantities of surface Shaft seal
water and ground water in places such as
AP51.65.22 to Combination of mechanical
• holiday homes, AP51.65.35 bellows seal and lip seal.
• public buildings, The primary shaft seal has silicon
• factories, carbide/silicon carbide seal faces.
The secondary shaft seal is a lip
• garages,
seal. The chamber between the
• underground car parks and shaft seals is filled with 0.01 litre of
• car wash areas. oil.
If permitted by local laws or regulations, the AP51 pumps AP51.65.22 to Two mechanical bellows seals,
can be used for the pumping of sewage from single and AP51.65.35 with silicon carbide/silicon carbide
multi-family houses. seal faces. The chamber between
the primary and the secondary
Pump and stator housing shaft seals is filled with 1.2 litre of
oil.
The pump housing and the stator housing are made of
cast iron. Motor cable
The stator housing is dry, i.e. not oil-filled.
Standard pumps 10 m: H07RNF.

Discharge Materials
All AP51 pumps have a horizontal R 2½ discharge port for
Description Materials DIN W.-Nr. AISI
threaded connection.
Stator housing Cast iron GG 25 0.6025 ASTM 35B
Pump housing Cast iron GG 25 0.6025 ASTM 35B
Shaft and bearings Neck ring Bronze
Impeller Cast iron GG 25 0.6025 ASTM 35B
The shaft is made of stainless steel and rotates in main-
Shaft Stainless steel 1.4104 AISI 430F
tenance-free prelubricated ball bearings.
Bearings Heavy-duty prelubricated ball bearings
The lower bearing of AP51.65.22, AP51.65.23, AP51.65.34 Screws Stainless steel 1.4301 AISI 304
and AP51.65.35 comprises a double row of ball bearings. Oil Shell Ondina 15, non-toxic

Control box
Further information about control box, float switch, and
level controller, see page 40.

32
Performance curves AP51

p H
[kPa] [m]
34
AP51.65.
.3
60 Hz
28
ISO 2548 Annex B

35
.3
240
24
23
.3

20
22
.3

160 16 15
.3

14
.3
12
13
.1
09
80 .3
8
09
.1

0 0
0 10 20 30 40 50 60 70 Q [m³/h]

0 5 10 15 20 Q [l/s]
P1 P1
[hp] [kW]

4 34.3 35.3

4 3
23.3

2
15.3
13.1 22.3
2 14.3
09.3
1 09.1

0 0
0 10 20 30 40 50 60 70 Q [m³/h]
TM00 6774 4799

33
Technical data AP51

S
A
E

C
D

TM01 2564 2098


B

Elbow is an accessory.

P1 P2 n Dimensions [mm]
In I start Weight
Pump type Voltage Cos ϕ ---------
[kW] [kW] [min-1] [A] In A B C D E S [kg]

AP51.65.09.1 1 x 230 V 1.2 0.9 3450 5.4 0.97 6.0 465 350 124 65 198 R 2½ 27 - 28
AP51.65.09.A1 1 x 230 V 1.2 0.9 3450 5.4 0.97 6.0 465 350 124 65 198 R 2½ 27 - 28
AP51.65.09.3 3 x 230 V 1.2 0.9 3450 4.0 0.79 6.0 465 350 124 65 198 R 2½ 26
AP51.65.09.3 3 x 380 V 1.2 0.9 3450 2.3 0.79 6.0 465 350 124 65 198 R 2½ 26
AP51.65.09.3 3 x 460 V 1.2 0.9 3450 1.9 0.79 6.0 465 350 124 65 198 R 2½ 26
AP51.65.13.1 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 465 350 124 65 198 R 2½ 28 - 29
AP51.65.13.A1 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 465 350 124 65 198 R 2½ 28 - 29
AP51.65.14.3 3 x 230 V 1.8 1.4 3450 5.6 0.83 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3 3 x 380 V 1.8 1.4 3450 3.3 0.83 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3 3 x 460 V 1.8 1.4 3450 2.7 0.83 6.0 465 350 124 65 198 R 2½ 27
AP51.65.15.3 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.15.3 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.15.3 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.22.3 3 x 230 V 2.8 2.2 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.22.3 3 x 380 V 2.8 2.2 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.22.3 3 x 460 V 2.8 2.2 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.23.3 3 x 230 V 2.8 2.3 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.23.3 3 x 380 V 2.8 2.3 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.23.3 3 x 460 V 2.8 2.3 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.34.3 3 x 230 V 4.0 3.4 3450 12.5 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.34.3 3 x 380 V 4.0 3.4 3450 6.7 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.34.3 3 x 460 V 4.0 3.4 3450 6.0 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.35.3 3 x 230 V 4.0 3.5 3450 12.5 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.35.3 3 x 380 V 4.0 3.5 3450 6.7 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.35.3 3 x 380 V 4.0 3.5 3450 6.0 0.84 6.0 518 368 101 50 185 R 2½ 45

34
Technical data AP51

AP51 installations

A B
C
D
F

S ‹



‹ ‹

‹ ‹

‹ ‹
‹ ‹

‹ ‹
‹ ‹

‹ ‹
‹ ‹ ‹


‹ ‹


‹ ‹
‹ ‹ ‹
‹ ‹
‹ ‹



‹ ‹ ‹

‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹
‹ ‹
‹ ‹ ‹
‹ ‹ ‹
‹ ‹
‹ ‹ ‹
‹ ‹ ‹

‹ ‹ ‹ ‹
‹ ‹
‹ ‹
V

‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹

‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
U

‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
J

‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹

‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹

‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹

G
I
H
TM01 2565 2098

TM01 2566 2098


K L M M

N O P R P

One-pump installation on auto-coupling


Pump type A B C D E F G H I J K L M N O P S T U V
AP51.65.09.1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.09.A1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.09.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.13.1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.13.A1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.14.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.15.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.22.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.23.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.34.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.35.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

Two-pump installation on auto-coupling


Pump type A B C D E F G H I J K L M N O P R S T U V
AP51.65.09.1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.09.A1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.09.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.13.1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.13.A1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.14.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.15.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.22.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.23.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.34.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.35.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

35
Technical data AP51 Vortex

AP51 with Vortex impeller Impeller


The impeller is a vortex impeller in cast iron GG 25 with
a free passage of 51 mm in the pump housing. Cast iron
is chosen as it is resistant towards mechanically wearing
particles.

TM01 2617 2098


TM01 7174 4099

The pumps are used for pumping wastewater, sludge-


containing water, considerable quantities of surface Shaft seal
water and ground water in places such as AP51.65.14, Combination of mechanical bellows
• holiday homes, AP51.65.15: seal and lip seal. The primary shaft
seal is made of silicon carbide/silicon
• public buildings,
carbide. The secondary shaft seal is a
• factories, lip seal. The chamber between the
• garages, shaft seals is oil-filled.
• underground car parks and AP51.65.23, Two mechanical bellows seals and a
• car wash areas. AP51.65.34, lip seal.
AP51.65.35, The primary and the secondary shaft
If permitted by local laws or regulations, the AP51 Vortex AP51.65.36: seals are made of silicon carbide/
pumps can be used for the pumping of sewage from silicon carbide. The chamber between
single and multi-family houses. the primary and the secondary shaft
seals is oil-filled. Between the lower
Pump and stator housing ball bearing and the stator housing
there is a lip seal.
The pump housing and the stator housing are made of
cast iron.
Motor cable
The stator housing of AP51.65.14V and AP51.65.15V is dry,
i.e. not oil-filled. Standard pumps 10 m: H07RNF.
The stator housing of AP51.65.23V, AP51.65.34V,
AP51.65.35V and AP51.65.36V is oil-filled. Materials
All AP51 pumps are fitted with casted legs for free- Description Materials DIN W.-Nr. AISI

standing installation. Stator housing Cast iron GG 25 0.6025 ASTM 35B


Pump housing Cast iron GG 25 0.6025 ASTM 35B
Neck ring Bronze
Discharge Impeller Cast iron GG 25 0.6025 ASTM 35B
All AP51 pumps have a horizontal R 2½ discharge port for Shaft Stainless steel 1.4104 AISI 430F
threaded connection. Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304

Shaft and bearings Oil Shell Ondina 15, non-toxic

The shaft is made of chromium steel and rotates in Control box


maintenance-free prelubricated ball bearings.
Further information about control box, float switch, and
The lower bearing of AP51.65.23V, AP51.65.34V and
level controller, see page 40.
AP51.65.36V comprises a double row of ball bearings.
All AP51 pumps are fitted with casted legs for free-
standing installation.

36
Performance curves AP51 Vortex

p H
[kPa] [m]
240 24 AP
51
AP51
.65 60 Hz
.36
220 22 .3.
V ISO 2548 Annex B
200 20 AP5
1.65
180 18
.35.
3.V
AP5
1.65
160 16 .34.
3.V

140 14 AP
51.
65.
120 12 AP5
23.
3.V
1.65
.15.
100 3.V
10
AP5
1.65
.14.3
80 8 .V
AP5
1.65
.14.1
60 6 .V

40 4
20 2
0 0
0 5 10 15 20 25 30 35 40 45 Q [m³/h]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 Q [l/s]
P1 P1
[hp] [kW] AP51.65.35.3.V AP51.65.34.3.V
4.0 AP51.65.36.3.V
5 3.5 .3.V
.65.23
4 3.0 AP51
2.5
3
2.0 AP51.65.14.3.V AP51.65.14.1.V
AP51.65.15.3.V
2 1.5
1.0
1
0.5
0 0.0
0 5 10 15 20 25 30 35 40 45 Q [m³/h]
TM00 6776 4799

37
Technical data AP51 Vortex

S
A
E

C
D

TM01 2564 2098


B

Elbow is an accessory.

P1 P2 n Dimensions [mm]
In I start Weight
Pump type Voltage Cos ϕ ---------
[kW] [kW] [min-1] [A] In A B C D E S [kg]

AP51.65.14.1.V 1 x 230 V 1.8 1.4 3450 8.0 0.99 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.A1.V 1 x 230 V 1.8 1.4 3450 8.0 0.99 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3.V 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3.V 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3.V 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.15.3.V 3 x 230 V 1.8 1.4 1750 5.4 0.70 6.0 518 368 101 50 187 R 2½ 27
AP51.65.15.3.V 3 x 380 V 1.8 1.4 1750 3.2 0.70 6.0 518 368 101 50 187 R 2½ 27
AP51.65.15.3.V 3 x 460 V 1.8 1.4 1750 2.6 0.70 6.0 518 368 101 50 187 R 2½ 27
AP51.65.23.3.V 3 x 230 V 2.8 2.3 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 40
AP51.65.23.3.V 3 x 380 V 2.8 2.3 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 40
AP51.65.23.3.V 3 x 460 V 2.8 2.3 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 40
AP51.65.34.3.V 3 x 230 V 4.0 3.4 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.34.3.V 3 x 380 V 4.0 3.4 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.34.3.V 3 x 460 V 4.0 3.4 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.35.3.V 3 x 230 V 4.0 3.5 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.35.3.V 3 x 380 V 4.0 3.5 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.35.3.V 3 x 460 V 4.0 3.5 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.36.3.V 3 x 230 V 4.0 3.6 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.36.3.V 3 x 380 V 4.0 3.6 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.36.3.V 3 x 460 V 4.0 3.6 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45

38
Technical data AP51 Vortex

AP51 installations

A B
C D
F

S ‹



‹ ‹

‹ ‹

‹ ‹
‹ ‹

‹ ‹
‹ ‹

‹ ‹
‹ ‹ ‹


‹ ‹
‹ ‹ ‹

‹ ‹
‹ ‹ ‹

‹ ‹ ‹
‹ ‹



‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹

‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
V

‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
U

‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
J

‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹

‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹ ‹
‹ ‹ ‹ ‹

I
G
H M M
TM01 2565 2098

TM01 2566 2098


K L P R P
N O

One-pump installation on auto-coupling


Pump type A B C D E F G H I J K L M N O P S T U V
AP51.65.14.1.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.14.A1.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.14.3.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.15.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.23.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.34.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.35.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.36.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

Two-pump installation on auto-coupling


Pump type A B C D E F G H I J K L M N O P R S T U V
AP51.65.14.1.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.14.A1.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.14.3.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.15.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.23.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.34.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.35.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.36.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

39
Technical data Control box

Control box
Variants
The AP pump range comprises versions with or without
control box and float switch, versions designed for
single-phase or three-phase power supply versions.
All types are designed for voltage tolerances of ±10%.

Pumps with control box and float switch


Some AP pumps can be supplied with a float switch for
automatic start/stop of the pump. The float switch cable
should be fastened to the retainer on the pump handle.
The difference in level between start and stop may be

TM00 6671 2298


adjusted by adjusting the free length of cable between
the float switch and the retainer.
Large difference in level: Long cable.
Small difference in level: Short cable.
The float switch is connected directly to the control box Pump with control box and float switch.
through a 10 metres long cable.
The mains cable between the pump and the control box
is 10 metres long. The mains cable of the control box is
an 0.8 metres long free cable end.
The control box includes a motor starter, and for single-
phase pumps also an operating capacitor. The pumps
require no further motor protection.
An alarm signal can be given in case of a too high level
by means of a separate float switch connected to an
alarm. The high-level alarm switch and the alarm are
available as accessories.
Further information about control boxes for a specific

TM00 6670 2298


pump type, see "Product range", page 49.

Pumps with control box without float switch for


manual on/off operation
The mains cable between the pump and the control- box
Pumps with control box without float switch for manual
is 10 metres long. The mains cable of the control box is
on/off operation.
an 0.8 metres long free cable end.
The control box includes a motor starter and an oper-
ating capacitor but no relays for float switch. CU 212
1
2 1 2

Pumps without control box.


Pumps without control box must be connected to a
separate motor starter. The motor starter is available as
an accessory.
Single-phase pumps must also be connected to a capac-
itor.

Level controller
A level controller and switches are available as optional
TM00 6672 0800

extras for the control, monitoring and protection of


three-phase 60 Hz AP pumps. Level controller LC is
designed for one-pump operation, and LCD for two-
pump operation.
The level controller incorporates motor starter, contac- Two pumps with level controller LCD.
tors and light-emitting diodes (LC/LCD) for indication of
operating condition.

40
Technical data AP80

AP80 Shaft seal


The pumps are used for pumping sewage, wastewater, Two mechanical bellows seals with silicon carbide/
considerable quantities of surface water and ground silicon carbide seal faces.
water in places such as
The chamber between the primary and the secondary
• municipal pump pits, shaft seal is filled with
• public buildings, • AP80.100.15-65 1.7 litres
• block of flats, • AP80.100.74-107 3.0 litres
• factories and
• underground car-parks. Installation
All AP80 pumps are fitted with motors for direct-on-line
Pump and stator housing starting. AP80 pumps with motors for star-delta starting
The pump housing and the stator housing are made of are available on request.
cast iron.
The stator housing is dry, i.e. not oil-filled.
Motor cable
Standard pumps 10 m: H07RNF
Discharge
All AP80 pumps have a horizontal discharge port with a
Materials
DN 100 DIN flange. Description Materials DIN W.-Nr. AISI/ASTM
Stator housing Cast iron GG 25 0.6025 ASTM 35B

Shaft and bearings Pump housing Cast iron GG 25 0.6025 ASTM 35B
Neck ring Bronze
The shaft is made of stainless steel and rotates in main- Impeller Cast iron GG 25 0.6025 ASTM 35B
tenance-free prelubricated ball bearings. Shaft Stainless steel 1.4104 AISI 430F
The lower bearing is a double-row ball bearing. Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304
Impeller Cooling jacket Stainless steel 1.4301 AISI 304
Oil Shell Ondina 15, non-toxic
The impeller is a single-channel cast iron impeller with a
clearance of 80 mm. Cast iron is chosen as it is resistant
towards mechanically wearing particles.
Cooling jacket
On request all AP80 pumps can be supplied with a stain-
less steel cooling jacket.
Liquid temperature with cooling jacket: 0°C to +40°C.
For short periods, max. one hour: Up to +60°C. For
periods longer than one hour, external cooling is
required.
TM00 5488 0895

The cooling jacket is available for internal as well as


external cooling of the motor in both dry and submerged
installations.
Internal cooling (standard) is achieved by leading part of
The inlet side of the pump housing is fitted with a the pumped liquid around the stator housing and back
replaceable neck ring. to the pump housing via internal channels.
For external cooling the cooling jacket is fitted with
Level controller sockets for pipe connections.
Further information about level controller, see page 40. The cooling jacket is required for cooling of the motor in
dry installations, and in submerged installations if the
pump is not completely submerged during continuous
operation.

41
Performance curves AP80

p H
[kPa] [m]
30 AP80.100
280 60 Hz
28
ISO 2548 Annex B
260
26
240
24
220
22
AP
200 80.
20 100
.10
7
180 AP
18 80.
100
.87
160 AP
16 80.
100
AP .74
140 14 80.
100
AP8 .65
120 12 0.10
0.47
100 AP8
10 0.10
0.35
AP
80 8 80.
100
AP .27
80.
60 6 100
.21
AP
40 80.
4 100
.15
20 2

0 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]

0 5 10 15 20 25 30 35 40 45 50 55 60 Q [l/s]

P1 P1
[hp] [kW]
12 107
16

14 10 87
12
8 74
10 65

8 6
47
6
4 35
4 27
2 21
2 15

0 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
TM01 3637 4498

42
Technical data AP80

DN 100/DN 100
AP80.100.15-74 AP80.100.87-107
X X
60 87 60 87

ø15 ø15 W

1 1/2" 1 1/2"
DN100 200 DN100 200

U
U
415

415
240

240
V

V
DN100 DN100

20 20 20 20

H
H

200
200
270

270
G

G
TM01 4254 5098

TM01 4258 5098


240 240
Y Y

DN 150/DN 100
AP80.100.15-74 AP80.100.87-107
X X
100 110 100 110

ø15 ø15
W

2" 2"
U

DN150 280 DN150 280


U
450

450
275

275
V

DN100 DN100

20 20 20 20
H

H
400
300

400
300
G

TM01 4702 0799


TM01 4701 0799

340 340
Y Y

43
Technical data AP80

Submerged free-standing
installation
AP80.100.15-74 AP80.100.87-107

E
E
F
F

DN100 120

A
A

DN100 120

B
B
C
D

C
DN100

D
DN100
125

ø395

125
ø395
H
G

H
G

TM01 4259 5098


TM01 4255 5098

J
J

44
Technical data AP80

Dimensions for installation on auto-coupling DN 100


Dimensions [mm]
Pump type
V W U G H X Y
AP80.100.15 147 347 852 307 147 589 767
AP80.100.21 147 347 852 307 147 589 767
AP80.100.27 147 347 852 307 147 589 767
AP80.100.35 147 347 852 307 147 589 767
AP80.100.47 147 347 922 307 147 589 767
AP80.100.65 122 377 927 363 165 643 871
AP80.100.74 122 377 927 363 165 643 871
AP80.100.87 122 377 1023 363 165 643 871
AP80.100.107 122 377 1083 363 165 643 871

Dimensions for installation on auto-coupling DN 150


Dimensions [mm]
Pump type
V W U G H X Y
AP80.100.15 156 425 961 307 147 714 1027
AP80.100.21 156 425 961 307 147 714 1027
AP80.100.27 156 425 961 307 147 714 1027
AP80.100.35 156 425 961 307 147 714 1027
AP80.100.47 156 425 961 307 147 714 1027
AP80.100.65 156 425 961 363 165 714 1027
AP80.100.74 156 425 961 363 165 714 1027
AP80.100.87 156 425 1207 363 165 714 1027
AP80.100.107 156 425 1207 363 165 714 1027

Dimensions for submerged free-standing installation


Dimensions [mm]
Pump type
A B D E F G H
AP80.100.15 705 830 218 355 200 307 147
AP80.100.21 705 830 218 355 200 307 147
AP80.100.27 705 830 218 355 200 307 147
AP80.100.35 705 830 218 355 200 307 147
AP80.100.47 775 900 218 355 200 307 147
AP80.100.65 805 930 244 459 280 363 165
AP80.100.74 805 930 244 459 280 363 165
AP80.100.87 901 1026 244 459 280 363 165
AP80.100.107 961 1086 244 459 280 363 165

45
Technical data AP80

Electrical data and weights


P1 P2 n In I start Weights
Pump type Voltage Cos ϕ ---------
[kW] [kW] [min-1] [A] In [kg]

AP80.100.15 3 x 230 V 1.7 1.5 1750 6.2 0.87 1.3 95


AP80.100.15 3 x 380 V 1.7 1.5 1750 3.8 0.87 1.3 95
AP80.100.15 3 x 440 V 1.7 1.5 1750 3.2 0.87 1.3 95
AP80.100.15 3 x 460 V 1.7 1.5 1750 3.1 0.87 1.3 95
AP80.100.21 3 x 230 V 2.6 2.1 1750 7.8 0.87 4.0 95
AP80.100.21 3 x 380 V 2.6 2.1 1750 4.7 0.87 4.0 95
AP80.100.21 3 x 440 V 2.6 2.1 1750 4.1 0.87 4.0 95
AP80.100.21 3 x 460 V 2.6 2.1 1750 3.9 0.87 4.0 95
AP80.100.27 3 x 230 V 3.2 2.7 1750 9.2 0.86 6.0 99
AP80.100.27 3 x 380 V 3.2 2.7 1750 5.6 0.86 6.0 99
AP80.100.27 3 x 440 V 3.2 2.7 1750 4.8 0.86 6.0 99
AP80.100.27 3 x 460 V 3.2 2.7 1750 4.6 0.86 6.0 99
AP80.100.35 3 x 230 V 4.1 3.5 1750 12.0 0.87 5.0 100
AP80.100.35 3 x 380 V 4.1 3.5 1750 7.3 0.87 5.0 100
AP80.100.35 3 x 440 V 4.1 3.5 1750 6.3 0.87 5.0 100
AP80.100.35 3 x 460 V 4.1 3.5 1750 6.0 0.87 5.0 100
AP80.100.47 3 x 230 V 5.5 4.7 1750 16.0 0.87 5.5 124
AP80.100.47 3 x 380 V 5.5 4.7 1750 9.7 0.87 5.5 124
AP80.100.47 3 x 440 V 5.5 4.7 1750 8.4 0.87 5.5 124
AP80.100.47 3 x 460 V 5.5 4.7 1750 8.0 0.87 5.5 124
AP80.100.65 3 x 230 V 7.5 6.5 1750 22.0 0.87 5.0 126
AP80.100.65 3 x 380 V 7.5 6.5 1750 13.3 0.87 5.0 126
AP80.100.65 3 x 440 V 7.5 6.5 1750 11.5 0.87 5.0 126
AP80.100.65 3 x 460 V 7.5 6.5 1750 11.0 0.87 5.0 126
AP80.100.74 3 x 230 V 8.5 7.4 1750 24.6 0.87 5.0 126
AP80.100.74 3 x 380 V 8.5 7.4 1750 14.9 0.87 5.0 126
AP80.100.74 3 x 440 V 8.5 7.4 1750 12.9 0.87 5.0 126
AP80.100.74 3 x 460 V 8.5 7.4 1750 12.3 0.87 5.0 126
AP80.100.87 3 x 230 V 10.7 8.7 1750 29.0 0.88 5.0 196
AP80.100.87 3 x 380 V 10.7 8.7 1750 17.6 0.88 5.0 196
AP80.100.87 3 x 440 V 10.7 8.7 1750 16.0 0.88 5.0 196
AP80.100.87 3 x 460 V 10.7 8.7 1750 14.5 0.88 5.0 196
AP80.100.107 3 x 230 V 12.3 10.7 1750 37.0 0.82 7.0 223
AP80.100.107 3 x 380 V 12.3 10.7 1750 22.4 0.82 7.0 223
AP80.100.107 3 x 440 V 12.3 10.7 1750 19.3 0.82 7.0 223
AP80.100.107 3 x 460 V 12.3 10.7 1750 18.5 0.82 7.0 223

46
Technical data APG

APG pumps

TM01 7182 4099

TM00 3576 5193


APG pumps are specifically designed for the pumping of An adjustable cast iron wear plate is fitted at the inlet
sewage from small villages and farms, and in areas of side of the impeller.
difficult topography, e.g. rocky terrain with large differ-
ences in level.
Shaft and bearings
A cutter system at the impeller inlet cuts destructible
solids into small pieces so that the sewage can be led The shaft is made of stainless steel and rotates in main-
away through pipes of a relatively small diameter. tenance-free prelubricated ball bearings.

Due to the pressurized pumping system, the APG pumps The lower bearing comprises a double row of ball bear-
are especially efficient in areas where traditional gravity ings.
pumping systems cannot be used.
Shaft seals
Approvals
APG.50.11 - 12:
PA-I no. 3986.
Combination of mechanical shaft seal and lip seal.

Pump and stator housing The primary shaft seal has silicon carbide/silicon carbide
seal faces. The secondary shaft seal is a lip seal. The
The pump housing and the stator housing are made of chamber between the shaft seals is filled with 0.7 litre of
cast iron. oil.
The stator housing is dry, i.e. not oil-filled.
APG.50.18 - 33:
Discharge Two mechanical bellows seals.

All APG pumps have an externally threaded discharge The primary and the secondary shaft seals have silicon
port: R 2. carbide/silicon carbide seal faces. The chamber between
the primary and the secondary shaft seals is filled with
1.2 litres of oil.
Impeller and cutter system
The impeller is a semi-open multivane cast iron im- Motor cable
peller.
Standard pumps 10 m: H07RNF.
The cutter system consists of a stationary ring with four
cutting edges and a rotating cutting head at the end of Materials
the pump shaft. The cutter system is made of
special,hardened high-alloy steel. Description Material DIN W.-Nr.
AISI/
ASTM
Stator housing Cast iron GG 25 0.6025 ASTM 35.B
Pump housing Cast iron GG 25 0.6025 ASTM 35.B
Wear plate Cast iron GG 25 0.6025 ASTM 35.B
Impeller Cast iron GG 25 0.6025 ASTM 35.B
Shaft Stainless steel 1.4104 AISI 430 F
Cutter system Hardened steel
Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304
Oil Shell Ondina 15, non-toxic

47
Performance curves APG

p H
[kPa] [m]
500
APG
50 AP
G. 60 Hz
50
.33 ISO 2548 Annex B
AP .1
45 G.
50
.29
AP .3
G.
400 50
40 .30
.1

35
AP
G.
50
.18
300 AP .1
30
G.
50
.19
.3
AP
25 G.5
0.1
1.3
AP
G.5
200 20 0.1
2.1

15

100 10

0 0
0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0 1 2 3 4 5 Q [l/s]
P1 P1
[hp] [kW]
6 APG.50.33.1
4 APG.50.30.1

APG.50.29.3
4 3
APG.50.19.3 APG.50.18.1

2 APG.50.12.1
2
APG.50.11.3
1

0 0
0 2 4 6 8 10 12 14 16 18 Q [m³/h]
TM00 7216 1599

48
Technical data APG

S
A
E

C
D

TM01 2603 2098


B

Elbow and ring stand are accessories.

P1 P2 Dimensions [mm]
n In I start Weight *
Pump type Voltage Cos ϕ ---------
[kW] [kW] [min] [A] In A B C D E S [kg]

APG.50.11.3 3 x 230 V 1.5 1.1 3450 6.2 0.63 6.0 450 304 133 90 207 R2 26
APG.50.11.3 3 x 380 V 1.5 1.1 3450 3.6 0.63 6.0 450 304 133 90 207 R2 26
APG.50.11.3 3 x 460 V 1.5 1.1 3450 3.0 0.63 6.0 450 304 133 90 207 R2 26
APG.50.12.1 1 x 230 V 1.5 1.2 3450 8.0 0.82 6.0 450 304 133 90 207 R2 28 - 30
APG.50.12.A1 1 x 230 V 1.5 1.2 3450 8.0 0.82 6.0 450 304 133 90 207 R2 28 - 30
APG.50.18.1 1 x 230 V 2.6 1.8 3450 12.0 0.94 6.0 620 408 191 150 265 R2 36 - 37
APG.50.18.A1 1 x 230 V 2.6 1.8 3450 12.0 0.94 6.0 620 408 191 150 265 R2 36 - 37
APG.50.19.3 3 x 230 V 2.6 1.9 3450 8.4 0.80 6.0 620 408 191 150 265 R2 33
APG.50.19.3 3 x 380 V 2.6 1.9 3450 4.9 0.80 6.0 620 408 191 150 265 R2 33
APG.50.19.3 3 x 460 V 2.6 1.9 3450 4.2 0.80 6.0 620 408 191 150 265 R2 33
APG.50.29.3 3 x 230 V 3.7 2.9 3450 11.4 0.86 6.0 751 408 191 150 265 R2 44
APG.50.29.3 3 x 380 V 3.7 2.9 3450 6.4 0.86 6.0 751 408 191 150 265 R2 44
APG.50.29.3 3 x 460 V 3.7 2.9 3450 5.2 0.86 6.0 751 408 191 150 265 R2 44
APG.50.30.1 1 x 230 V 3.7 3.0 3450 20.0 0.85 6.0 751 408 191 150 265 R2 48 - 50
APG.50.30.A1 1 x 230 V 3.7 3.0 3450 20.0 0.85 6.0 751 408 191 150 265 R2 48 - 50
APG.50.33.1 1 x 230 V 3.7 3.3 3450 20.0 0.80 6.0 751 408 191 150 265 R2 48 - 50
APG.50.33.A1 1 x 230 V 3.7 3.3 3450 20.0 0.80 6.0 751 408 191 150 265 R2 48 - 50
* Pump inclusive of cable.

49
Technical data APG

APG installations

A
B
C D
F

T
E
S




• •


• •
V



• •
• • •

• • •

• •
• •


• • •
‹ ‹
U


• ‹ ‹
• •
• • • •

• •
J


• •
• • ‹ ‹ ‹
• •
• • • ‹
• • • • • • ‹ ‹
• ‹ ‹
• • ‹ ‹
• • • ‹ ‹
• • • ‹
• •
• • •
‹ ‹
• • • • • • • ‹
• • ‹
• • • ‹
‹ ‹
• •
• • • • • •
• •

G I
TM01 2606 2098

TM01 2607 2098


K L M M
N O P R P

One-pump installation on auto-coupling


Pump type A B C D E F G I J K L M N O P S T U V
APG.50.11.3 ø600 ø600 393 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.12.1 ø600 ø600 393 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.12.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.18.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.18.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.19.3 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.29.3 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.30.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.30.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.33.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300
APG.50.33.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R2 ½" 160 300

Two-pump installation on auto-coupling


Pump type A B C D E F G I J K L M N O P R S T U V
APG.50.11.3 455 600 393 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.12.1 455 600 393 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.12.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.18.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.18.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.19.3 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.29.3 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.30.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.30.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.33.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300
APG.50.33.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R2 ½" 160 300

50
Accessories LC 107, LCD 107

LC 107, LCD 107


The LC 107 and LCD 107 pump controllers are designed LC 107
for level control, monitoring and protection of Grundfos
KP, AP and APG pumping systems up to
23 A/11 kW (P1) per pump starting direct-on-line.
• LC 107 is a one-pump controller.
• LCD 107 is a two-pump controller.
LC 107 and LCD 107 are supplied as a complete controller
incorporating motor protection relay, bell-shaped level
pickups, pneumatic tubes and control unit.
Pump
Control is based on pneumatic signals which the
LC 107 and LCD 107 receive via pneumatic tubes from 2 or
3 level pickups positioned in a pump pit.
The LC 107 and LCD 107 enable:
• control of 1 or 2 pumps based on signals from bell-
shaped level pickups,
High-level alarm
• automatic pump changeover (even distribution of
Settable Start of pump
operating hours on both pumps), stop delay Stop of pump
• automatic test run during long periods of inactivity

TM01 4921 1199


to prevent the shaft from seizing up,
• protection against water hammer as quick restart/
simultaneous start is blocked and delayed,
• battery back-up in case of mains supply failure
(accessory!),
• starting delay within the range from 0 to 255 sec.
(random) after returning from battery operation to LCD 107
mains operation (resulting in an even mains load
when several pumping stations are started up at the
same time),
• selection of automatic alarm resetting,
• selection of automatic restarting,
• setting of stop delays matching the actual operating
conditions,
• indication of liquid level,
• alarm indication of: Pump 2
– too high liquid level, which triggers a high-level
alarm, Pump 1
– overload (via motor protection relay),
– overtemperature (via PTC resistance/thermal
switch in motor),
– wrong phase sequence,
– mains supply failure, High-level alarm
Start of second pump
– failing level pickup. Start of first pump
Settable
stop delay Common stop
As standard, the LC 107 and LCD 107 have two alarm
TM01 4922 1199

signal outputs:
• common alarm,
• high-level alarm.

51
Accessories LC 107, LCD 107
LC 108, LCD 108

Technical data - mains supply failure (by installing a battery back-


up which is available as an accessory).
Voltage tolerances
As standard, the LC 108 controller incorporates a buzzer
–15%/+10% of nominal voltage. for indication of alarm.
Mains frequency Furthermore, the controller has one alarm output for
50/60 Hz. common alarm.

Ambient temperature Applications


• During operation: –30°C to +50°C The LC 108 can be connected and set to operation/
(must not be exposed to direct sunlight). control in 7 different ways:
• In stock: –30°C to +60°C. • systems with 2 float switches,
Enclosure class • systems with 3 float switches,
IP 55. • systems with 4 float switches,
• systems with 2 electrodes,
Pneumatic tubes
• systems with 3 electrodes,
• Maximum 20 m per tube
• systems for filling applications,
(standard: pneumatic tube of 10 metres).
• systems for drainage applications.
• Diameter: 10 mm.
• Material: PA 11.
Technical data
Outputs for alarm devices
Voltage tolerances
Max. 400 VAC / max. 2 A / min. 10 mA / AC 1.
–15%/+10% of nominal voltage.
LC 108, LCD 108 Mains frequency

The LC 108 pump controller is a one-pump controller 50/60 Hz.


designed for level control, monitoring and protection of Ambient temperature
pumps in wastewater, water supply and drainage
systems. • During operation: –30°C to +50°C
(must not be exposed to direct sunlight).
Up to 23 A/11 kW (P1) starting direct-on-line (DOL).
• In stock: –30°C to +60°C.
Up to 72 A/30 kW (P 1) starting star-delta (Y/D).
Enclosure class
The LC 108 is supplied as a complete controller incorpo-
rating motor protection relay and control unit. IP 55.
The LC 108 enables: Outputs for alarm devices
• control of one pump based on signals from float Max. 400 VAC / max. 2 A / min. 10 mA / AC 1.
switches, electrodes or flow switches, Supply system earthing
• automatic test run (every 24 hours) during long peri-
For TN systems and TT systems.
ods of inactivity to prevent the shaft from seizing up,
• protection against water hammer as quick restart is Rated insulation voltage, Ui
blocked and delayed (5 seconds), 4 kV.
• selection of automatic alarm resetting, Rated impulse withstand voltage, Uimp
• selection of automatic restarting (after overtempera-
4 kV.
ture),
• setting of stop delays matching the actual operating EMC (electromagnetic compatibility)
conditions, According to EN 50 081-1 and EN 50 082-2.
• indication of liquid level,
• alarm indication of:
• - wrong phase sequence,
- inadmissibly high liquid level,
- overload (via motor protection relay),
- overtemperature (via PTC resistance or thermal
switch in motor),
- defective float switch, electrode or flow switch,
- dry running,

52
Accessories LC 108, LCD 108

Level switches Dimensions


The AP pumps in combination with LC 108 or LCD 108 are
available with level switches for automatic level control.
Level switches supplied by Grundfos are of the non- B
mercury type.
LC 108 can be fitted with up to three level switches:
1. Min.: Stops the pump.
2. Max.: Starts the pump.
3. Alarm: Alarm (optional):
high water level or pump fault.
LCD 108 can be fitted with up to four level switches:

H
1. Min.: Stops both pumps.
2. Max. 1: Starts one pump.
3. Max. 2: Starts the other pump.
4. Alarm: Alarm (optional):
high water level or pump fault.
The level switches are to be installed in the pit floating
on the pumped liquid.
The position of the level switches decides when LC 108 or
LCD 108 starts and stops the AP pumps:

TM01 9007 0303


• When the level switch is pointing upwards, the level L
switch contact will be closed and the pump will start.
• When the level switch is pointing downwards, the
the level switch contact will be opened and the pump
will stop.
Dimensions [mm]
Type
H L B
LC 107, direct-on-line
350 250 136
LCD 107, direct-on-line
LC 108, direct-on-line
350 250 136
LCD 108, direct-on-line
LC 108, Star/delta 590 380 200
ON LCD 108, Star/delta 635 500 220

OFF
TM00 6678 4695

53
Accessories AP, KP

Accessories for AP, KP stainless steel pumps


Accessories Pump type
Product
Pos. AP AP AP AP AP AP
Description KP number
12.40 12.50 35 35B 50 50B
Rp 1½/2 ! ! 96 02 38 31
1 Bushing for pipe connection (PVC)
Rp 2/2½ ! ! 96 02 38 32
Rp 1½/1½ ! ! 96 00 39 97
Rp 1½/2 ! ! 96 02 38 34
2 Hose nipple (PVC)
Rp 2/2 ! ! 96 02 38 35
Rp 2/2½ ! ! 96 02 38 36
1½" ! ! 96 02 38 37
3 10 m rubber hose incl. clamps (PVC) 2" ! ! ! ! 96 02 38 38
2½" ! ! 96 02 38 39
RP 1½ ! ! 96 02 38 40
4 Connecting piece for rubber hoses (PVC) RP 2 ! ! ! ! 96 02 38 41
RP 2½ ! ! 96 02 38 42
Rp 1½ ! ! 96 02 38 43
Non-return valve (PVC)
5 Rp 2 ! ! ! ! 96 02 38 44
Ball type
Rp 2½ # ! ! 96 00 20 03
Rp 1½ ! ! 96 02 38 46
6 Isolating valve (PVC) Rp 2 ! ! ! ! 96 02 38 47
Rp 2½ ! ! 96 02 38 48
Rp 1½ ! ! 96 02 38 49
7 Hexagon nipple (PVC) Rp 2 ! ! ! ! 96 02 38 50
Rp 2½ ! ! 96 02 38 51
Rp 1½ ! ! 96 02 38 52
8 Union (PVC) Rp 2 ! ! ! ! 96 02 38 53
Rp 2½ ! ! 96 02 38 54
Rp 1½ ! ! 96 02 38 55
9 90° pipe bend (PVC) Rp 2 ! ! ! ! 96 02 38 56
Rp 2½ ! ! 96 02 38 57
Non-return valve Rp 1¼ ! 00 01 52 11
10 for location in the pump discharge
(stainless steel) Rp 1½ ! ! 96 00 38 55
Auto-coupling Rp 2/Rp 2 ! ! 96 42 95 19
G 1¼ x ø25 ! 00 ID 35 88
Hose couplings
G 1¼ x ø32 ! 00 ID 35 89
Screwed couplings (polyamide)
G 1¼ x ø40 ! 00 ID 35 90
# Cast iron

7
3 6
4 7
3 5 1010
2 7

8 10
1
TM01 8708 0700
TM00 5924 1895

TM00 5925 1895

54
Accessories AP

Accessories for cast iron AP pumps


Accessories Pump type
Product
AP51 number
Pos. Description AP30 AP51 AP80 APG
Vortex
R/Rp 2 ! 96 00 19 80
10 90° elbow
R/Rp 2½ ! ! 96 00 19 81
Coupling half Rp 2 2" hose ! ! 96 00 19 82
11
Storz coupling Rp 2½ - 2" hose ! ! 96 00 19 83
DN 100/DN 100 - 4" hose ! 96 00 34 24
Ring stand
12 DN 150/DN 100 - 4" hose ! 96 00 38 35
Ex. 90° elbow
R 2 (1.7/1.8/1.9/3.1 kW) ! 96 00 01 86
10 m rubber hose
13 2" ! ! 96 00 19 87
incl. couplings
Rp/Rp 2 ! ! 96 00 19 90
14 90° elbow
Rp/Rp 2½ ! ! 96 00 19 91
90° elbow with DN 65, PN 10 96 00 36 16
15
flanges DN 100, PN 10 ! 96 00 36 18
R/R 2 ! ! 96 00 19 93
16 Hexagon nipple
R/R 2½ ! ! 96 00 19 94
Rp 2 ! 96 00 44 51
17 Threaded flange Rp 2½ ! ! 96 00 19 96
Rp 4 ! 96 00 33 36
4 of each M16 x 65 mm
! ! 96 00 19 98
DN 65
18 Bolts, nuts and gaskets
8 of each M16 x 65 mm
! 96 00 38 23
DN 100
DN 50 ! 96 00 54 68
19 Gasket DN 65 ! ! 96 00 20 00
DN 100 ! 96 00 33 31
Discharge pipe with DN 65, PN 10 ! ! 96 00 36 10
20 2 flanges , bolts, nuts and gaskets
Length = 1 m DN 100, PN 10 ! 96 00 36 12

Discharge pipe DN 65, PN 10 ! ! 96 00 36 13


20a
extension (1 m) DN 100, PN 10 ! 96 00 36 15
Non-return valve Rp/Rp 2 ! ! 96 00 20 02
21 Cast iron ball-type
valve Rp/Rp 2½ ! ! 96 00 20 03

Isolating valve Rp/Rp 2 ! ! 96 00 20 05


22
Brass Rp/Rp 2½ ! ! 96 00 20 06
Non-return valve DN 65 ! ! 96 00 20 08
23
Cast iron ball-type valve DN 100 ! 96 00 20 85
Isolating valve DN 65 ! ! 96 00 20 10
24
Cast iron DN 100 ! 96 00 20 12
Rp 2/Rp 2 ! 96 00 01 78
Rp 2/Rp 2 with slant claw ! 96 00 33 41
Auto-coupling Rp 2/Rp 2, hook-up ! ! 96 00 44 42
25
system complete DN 65/Rp 2½ ! ! 96 00 01 80
DN 100/DN 100 ! 96 00 66 58
DN 150/DN 100 ! 96 00 66 59
10 m ! ! ! ! ! 96 00 20 13
Chain with shackle - galvanized
26 6m ! ! 96 00 36 33
(AP100 up to and including 17 kW)
3m ! ! 96 00 36 34

Collecting steel pipes for two pumps and 90° out- 3 x DN 65 ! ! 96 00 36 19


27 let, centre discharge flanges are welded. Pipes are DN 65/65/80 ! ! 96 00 36 20
painted. 3 x DN 100 ! 96 00 36 23
Basestand
28 Dry pit stand DN 100/DN 100 ! 96 00 36 25
for vertical installation incl. 90° suction elbow
29 Cable protection 5 m x 1" ! ! ! ! 96 00 20 84

55
Accessories AP

Accessories Pump type


Product
AP51 number
Pos. Description AP30 AP51 AP80 APG
Vortex
Float switch without mercury 1 switch with 10 m cable ! ! ! ! ! 96 00 33 32
Float switch with 20 m cable ! ! ! ! ! 96 00 36 95
Bracket for level switch ! ! ! ! 96 00 33 38
1 pump without alarm
! ! ! ! ! 62 50 00 13
(2 switches)
30 1 pump with alarm
Standard float switch without mercury ! ! ! ! ! 62 50 00 14
(3 switches)
With 10 m cable, counter weight
and bracket 2 pumps without alarm
! ! ! ! ! 62 50 00 14
(3 switches)
2 pumps with alarm
! ! ! ! ! 62 50 00 15
(4 switches)
31 Signal lamp 1 x 230 V Outdoor mounting ! ! ! ! ! 62 50 00 20
Outdoor mounting ! ! ! ! ! 62 50 00 21
32 Acoustic signal (horn) 1 x 230V
Indoor mounting ! ! ! ! ! 62 50 00 22
DN 65, L = 1300 mm ! ! 96 00 38 42
DN 80, L = 1300 mm 96 00 38 43
Discharge pipe with 90° bend and two flanges.
33 DN 100, L = 1300 mm ! 96 00 38 44
For 1 pump.
DN 150, L = 1300 mm ! 96 00 38 45
DN 150, L = 1600 mm ! 96 00 39 79
DN 65, L = 1920 mm ! ! 96 00 38 46
DN 80, L = 1920 mm 96 00 38 47
Collecting steel pipes for two pumps.
34 DN 100, L = 1920 mm ! 96 00 38 48
Sideways discharge
DN 150, L = 1920 mm ! 96 00 38 49
DN 150, L = 2220 mm ! 96 00 39 80

56
Accessories AP

Level controllers and accessories

including combined hour


including start counter*
including hour counter*
Grundfos product no.

Grundfos product no.

Grundfos product no.

and start counter*


Operating current

Mains switch
per pump [A]

Product no.*
required [A]

Grundfos
Description

1 - 2.9
LC 107 level controller for 25 96 00 24 64
1 pump 1.6 - 5.0 25 96 00 24 65
TM01 8874 0800

1 x 230 V, direct-on-line starting


3.7 - 12.0 25 96 00 24 66
1 - 2.9 25 96 00 24 67
LC 107 level controller for 1.6 - 5.0 25 96 00 24 68
1 pump
3 x 400 V, direct-on-line starting 3.7 - 12.0 25 96 00 24 69
12.0 - 23.0 40 96 00 24 70
LCD 107 level controller for 1 - 2.9 25 96 00 24 71
2 pumps 1.6 - 5.0 25 96 00 24 72
TM01 8875 0800

1 x 230 V, direct-on-line starting 3.7 - 12.0 25 96 00 24 73


1 - 2.9 25 96 00 24 74
LCD 107 level controller for 1.6 - 5.0 25 96 00 24 75
2 pumps
3 x 400 V, direct-on-line starting 3.7 - 12.0 25 96 00 24 76
12.0 - 23.0 40 96 00 24 77
1 - 2.9 25 96 43 39 56 96 43 39 57 96 43 39 58 96 43 39 59
LC 108 level controller for 1.6 - 5.0 25 96 43 39 61 96 43 39 60 96 43 39 62 96 43 39 63
1 pump
1 x 230 V, direct-on-line starting 3.7 - 12.0 25 96 43 39 64 96 43 39 65 96 43 39 66 96 43 39 67
12.0 - 23.0 40 96 43 39 71 96 43 39 72 96 43 39 73 96 43 39 74
1 - 2.9 25 96 43 39 75 96 43 39 76 96 43 39 77 96 43 39 78
LC 108 level controller for 1.6 - 5.0 25 96 43 39 79 96 43 39 80 96 43 39 81 96 43 39 82
1 pump
3 x 230 V, direct-on-line starting 3.7 - 12.0 25 96 43 39 83 96 43 39 84 96 43 39 85 96 43 39 86
TM01 8873 0800

12.0 - 23.0 40 96 43 39 87 96 43 39 88 96 43 39 89 96 43 39 90
1 - 2.9 25 96 43 39 91 96 43 39 92 96 43 39 93 96 43 39 94
LC 108 level controller for 1.6 - 5.0 25 96 43 39 95 96 43 39 96 96 43 39 97 96 43 39 98
1 pump
3 x 400 V, direct-on-line starting 3.7 - 12.0 25 96 43 39 99 96 43 40 00 96 43 40 01 96 43 40 02
12.0 - 23.0 40 96 43 40 03 96 43 40 04 96 43 40 05 96 43 40 06
6.4 - 20.0 25 96 43 79 28
LC 108 level controller for 20.8 - 30.0 40 96 43 79 50
1 pump
3 x 400 V, star-delta starting 20.8 - 59.0 80 96 43 79 70
24.2 - 72.0 96 43 79 90
1 - 2.9 25 96 43 40 23 96 43 40 24 96 43 40 25 96 43 40 26
LCD 108 level controller for 1.6 - 5.0 25 96 43 40 27 96 43 40 28 96 43 40 29 96 43 40 30
2 pumps
3 x 230 V, direct-on-line starting 3.7 - 12.0 25 96 43 40 31 96 43 40 32 96 43 40 33 96 43 40 34
12.0 - 23.0 40 96 43 40 35 96 43 40 36 96 43 40 37 96 43 40 38
1 - 2.9 25 96 43 40 39 96 43 40 40 96 43 40 41 96 43 40 42
LCD 108 level controller for 1.6 - 5.0 25 96 43 40 43 96 43 40 44 96 43 40 45 96 43 40 46
2 pumps
3 x 400 V, direct-on-line starting 3.7 - 12.0 40 96 43 40 47 96 43 40 48 96 43 40 49 96 43 40 50
TM01 8876 0800

12.0 - 23.0 60 96 43 40 51 96 43 40 52 96 43 40 53 96 43 40 54
6.4 - 20.0 25 96 43 80 32
LCD 108 level controller for 20.8 - 30.0 40 96 43 80 52
2 pumps
3 x 400 V, star-delta starting 20.8 - 59.0 80 96 43 80 72
24.2 - 72.0 96 43 80 92
*Includes Instruction and operating manual in English. Other languages are available on request.

Accessories for controllers


Grundfos
Description
product no.
Battery back-up 96 00 25 20
Flashing beacon for external alarm indication 62 50 00 20
Alarm horn for external alarm indication (outdoor installation) 62 50 00 21
Alarm horn for external alarm indication (indoor installation) 62 50 00 22
Hour counter [230 V] 96 00 25 14
Hour counter [400 V] 96 00 25 15
Start counter [230 V] 96 00 25 16
Start counter [400 V] 96 00 25 17
Combined hour and start counter [230 V] 96 00 25 18
Combined hour and start counter [400 V] 96 00 25 19
25 [A] external mains switch for supply cable 96 00 25 11
40 [A] external mains switch for supply cable 96 00 25 12
80 [A] external mains switch for supply cable 96 00 25 13
LC-Ex4 96 44 03 00

57
Accessories AP

Free-standing installation or portable Vertical dry installation (D)


AP30 AP80
AP51
AP51 Vortex
AP80
APG

15
24
23
13
20
11

10
15

12 24
TM01 2542 2098

TM01 0749 1398


28

Installation on auto-coupling Installation on auto-coupling


AP30 AP80
AP51
AP51 Vortex
APG

25
15
25 24
14 23
22 20
16 17
21 19 26
26 DN80/
R2/DN65 DN100/ 25
25 DN150/
17 DN200/
DN250/
19 DN300/
18 18
TM00 5616 1398
TM01 2543 2098

25 25

58
Accessories AP, APG

Level controllers and accessories Pipe dimensions

DN
DN22
27
27

TM00 3618 0794


DN
DN11

BB
29
29

TM01 0753 2197


C
C A

Dimensions DN 1 DN 2 A B C Prod. no.

TM01 6982 3999


3 x DN 65, PN 10 65 65 140 140 380 96 00 36 19
DN 65/ 65/ 80, PN 10 65 80 140 235 380 96 00 36 20
30 3 x DN 100, PN 10 100 100 205 205 611 96 00 36 23

33
37
TM01 7286 4299

TM01 0898 1498


31 AA

Dimensions A Prod. no.


2 x DN 65, PN 10 1300 96 00 38 42
2 x DN 100, PN 10 1300 96 00 38 44
TM01 7187 4099

2 x DN 150, PN 10 for 1.5 m pit 1300 96 00 38 45


2 x DN 150, PN 10 for 2.0 m pit 1300 96 00 38 79
32

38
34

TM01 0899 3797


AA B
B
C
C

Dimensions A B C Prod. no.


3 x DN 65, PN 10 620 1300 1920 96 00 38 46
3 x DN 100, PN 10 620 1300 1920 96 00 38 48
3 x DN 150, PN 10 for 2.0 m pit 620 1300 1920 96 00 38 49
3 x DN 150, PN 10 for 2.5 m pit 620 1600 2220 96 00 39 80

59
Product range KP

KP 150
Vertical Discharge
Pump type Voltage Float switch 3 m cable 5 m cable 10 m cable With plug Plug type Product no.
level switch connection
KP 150 1 x 100 V ! ! Japan Rp 1¼ 01 1B B1 00
KP 150 1 x 100 V ! ! ! Japan Rp 1¼ 01 1B B7 00
KP 150 1 x 115 V ! 10 ft ! USA NPT 1¼ 01 1D C0 01
KP 150 1 x 115 V ! 25 ft ! USA NPT 1¼ 01 1D C2 01

KP 250
Vertical Discharge
Pump type Voltage Float switch 3 m cable 5 m cable 10 m cable With plug Plug type Product no.
level switch connection
KP 250 1 x 100 V ! ! Japan Rp 1¼ 01 2B B1 00
KP 250 1 x 100 V ! ! ! Japan Rp 1¼ 01 2B B7 00
KP 250 1 x 115 V 10 ft ! USA NPT 1¼ 01 2D C0 01
KP 250 1 x 115 V 25 ft ! USA NPT 1¼ 01 2D C2 01
KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 66 00
KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 64 00
KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 68 00
KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 69 00
KP 250 3 x 200 V ! Rp 1¼ 01 2F 61 00

KP 350
Vertical Discharge
Pump type Voltage Float switch 3 m cable 5 m cable 10 m cable With plug Plug type Product no.
level switch connection
KP 350 1 x 100 V ! ! Japan Rp 1¼ 01 3B B1 00
KP 350 1 x 100 V ! ! ! Japan Rp 1¼ 01 3B B7 00
KP 350 1 x 115 V 10 ft ! USA NPT 1¼ 01 3D C0 01
KP 350 1 x 115 V 25 ft ! USA NPT 1¼ 01 3D C2 01
KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 66 00
KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 64 00
KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 68 00
KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 69 00
KP 350 3 x 200 V ! Rp 1¼ 01 3F 61 00

60
Product range AP12, AP30

AP12
Control box
Pump type Voltage with 0.8 m Level switch 10 m cable 3 m cable Product no.
supply cable
AP12.40.04.A1 1 x 220 - 230 V ! 96 02 39 21
AP12.40.04.A1 1 x 220 - 230 V ! ! 96 02 39 22
AP12.40.04.1 1 x 220 - 230 V ! 96 02 39 23
AP12.40.04.3 3 x 380 - 440 V ! 96 01 10 29
AP12.40.04.A3 3 x 380 - 440 V ! ! ! 96 01 10 42
AP12.40.04.3 3 x 200 - 220 V ! 96 01 10 27
AP12.40.04.A3 3 x 200 - 220 V ! ! ! 96 01 10 40
AP12.40.06.A1 1 x 220 - 230 V ! ! 96 01 06 54
AP12.40.06.1 1 x 220 - 230 V ! 96 01 06 59
AP12.40.06.3 3 x 380 - 440 V ! 96 00 17 76
AP12.40.06.A3 3 x 380 - 440 V ! ! ! 96 01 09 38
AP12.40.06.3 3 x 200 - 220 V ! 96 01 08 95
AP12.40.06.A3 3 x 200 - 220 V ! ! ! 96 01 09 37
AP12.40.08.A1 1 x 220 - 230 V ! ! 96 01 06 60
AP12.40.08.1 1 x 220 - 230 V ! 96 01 06 65
AP12.40.08.3 3 x 380 - 440 V ! 96 01 06 41
AP12.40.08.A3 3 x 380 - 440 V ! ! ! 96 01 09 41
AP12.40.08.3 3 x 200 - 220 V ! 96 01 08 96
AP12.40.08.A3 3 x 200 - 220 V ! ! ! 96 01 09 40
AP12.50.11.A1 1 x 220 - 230 V ! ! 96 01 06 78
AP12.50.11.1 1 x 220 - 230 V ! 96 01 06 82
AP12.50.11.3 3 x 380 - 440 V ! 96 01 06 42
AP12.50.11.A3 3 x 380 - 440 V ! ! ! 96 01 09 44
AP12.50.11.3 3 x 200 - 220 V ! 96 01 08 97
AP12.50.11.A3 3 x 200 - 220 V ! ! ! 96 01 09 43

AP30
Control box
Pump type Voltage with 0.8 m Level switch 10 m cable Product no.
supply cable
AP30.50.09.1.V 1 x 230 V ! ! 96 00 34 68
AP30.50.09.A1.V 1 x 230 V ! ! ! 96 00 34 69
AP30.50.09.3.V 3 x 230 V ! 96 00 34 70
AP30.50.09.3.V 3 x 380 V ! 96 00 34 71
AP30.50.09.3.V 3 x 460 V ! 96 00 34 72
AP30.50.13.1.V 1 x 230 V ! ! 96 00 34 73
AP30.50.13.A1.V 1 x 230 V ! ! ! 96 00 34 74
AP30.50.14.3.V 3 x 230 V ! 96 00 34 75
AP30.50.09.3.V 3 x 380 V ! 96 00 34 76
AP30.50.09.3.V 3 x 460 V ! 96 00 34 77

61
Product range AP35, AP35B, AP50, AP50B

AP35
Control box
Pump type Voltage with 0.8 m Level switch 10 m cable 3 m cable Product no.
supply cable
AP35.40.06.A1.V 1 x 220 - 230 V ! ! 96 01 06 66
AP35.40.06.1.V 1 x 220 - 230 V ! 96 01 06 71
AP35.40.06.3.V 3 x 380 - 440 V ! 96 01 06 43
AP35.40.06.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 47
AP35.40.06.3.V 3 x 200 - 220 V ! 96 01 08 98
AP35.40.06.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 46
AP35.40.08.A1.V 1 x 220 - 230 V ! ! 96 01 06 72
AP35.40.08.1.V 1 x 220 - 230 V ! 96 01 06 77
AP35.40.08.3.V 3 x 380 - 440 V ! 96 01 06 44
AP35.40.08.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 50
AP35.40.08.3.V 3 x 200 - 220 V ! 96 01 08 99
AP35.40.08.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 49

AP35B
Pump type Voltage Float switch 10 m cable 5 m cable With plug Product no.
AP35B.50.06.1.V 1 x 220-230 V ! ! 96 00 45 69
AP35B.50.06.A1.V 1 x 220-230 V ! ! ! 96 00 45 68
AP35B.50.06.3.V 3 x 200-220 V ! 96 00 45 71
AP35B.50.08.1.V 1 x 220-230 V ! ! 96 00 45 81
AP35B.50.08.A1.V 1 x 220-230 V ! ! ! 96 00 45 80
AP35B.50.08.3.V 3 x 200-220 V ! 96 00 45 83

AP50
Control box
Pump type Voltage with 0.8 m Level switch 10 m cable 3 m cable Product no.
supply cable
AP50.50.08.A1.V 1 x 220 - 230 V ! ! 96 01 06 84
AP50.50.08.1.V 1 x 220 - 230 V ! 96 01 06 88
AP50.50.08.3.V 3 x 380 - 440 V ! 96 01 06 47
AP50.50.08.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 53
AP50.50.08.3.V 3 x 200 - 220 V ! 96 01 09 00
AP50.50.08.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 52
AP50.50.11.A1.V 1 x 220 - 230 V ! ! 96 01 06 90
AP50.50.11.1.V 1 x 220 - 230 V ! 96 01 06 94
AP50.50.11.3.V 3 x 380 - 440 V ! 96 01 06 45
AP50.50.11.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 56
AP50.50.11.3.V 3 x 200 - 220 V ! 96 01 09 01
AP50.50.11.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 55

AP50B
Pump type Voltage Float switch 10 m cable 5 m cable With plug Product no.
AP50B.50.08.1.V 1 x 220-230 V ! ! 96 00 45 93
AP50B.50.08.A1.V 1 x 220-230 V ! ! ! 96 00 45 92
AP50B.50.08.3.V 3 x 200-220 V ! 96 00 45 95
AP50B.50.11.1.V 1 x 220-230 V ! ! 96 00 46 05
AP50B.50.11.A1.V 1 x 220-230 V ! ! ! 96 00 46 04
AP50B.50.11.3.V 3 x 200-220 V ! 96 00 46 07
AP50B.50.15.3.V 3 x 200-220 V ! 96 00 46 11

62
Product range AP51, AP51 Vortex

AP51 with single-vane impeller


Control box
Pump type Voltage with 0.8 m Level switch 10 m cable Product no.
supply cable
AP51.65.09.1 1 x 230 V ! ! 96 00 34 93
AP51.65.09.A1 1 x 230 V ! ! ! 96 00 34 94
AP51.65.09.3 3 x 230 V ! 96 00 34 95
AP51.65.09.3 3 x 380 V ! 96 00 34 96
AP51.65.09.3 3 x 460 V ! 96 00 34 97
AP51.65.13.1 1 x 230 V ! ! 96 00 35 57
AP51.65.13.A1 1 x 230 V ! ! ! 96 00 35 58
AP51.65.14.3 3 x 230 V ! 96 00 35 59
AP51.65.14.3 3 x 380 V ! 96 00 35 60
AP51.65.14.3 3 x 460 V ! 96 00 35 61
AP51.65.15.3 3 x 230 V ! 96 00 35 62
AP51.65.15.3 3 x 380 V ! 96 00 35 63
AP51.65.15.3 3 x 460 V ! 96 00 35 64
AP51.65.22.3 3 x 230 - 380 V ! 96 00 35 65
AP51.65.22.3 3 x 460 V ! 96 00 35 66
AP51.65.23.3 3 x 230 - 380 V ! 96 00 35 67
AP51.65.23.3 3 x 460 V ! 96 00 35 68
AP51.65.34.3 3 x 230 - 380 V ! 96 00 35 71
AP51.65.34.3 3 x 460 V ! 96 00 35 72
AP51.65.35.3 3 x 230 - 380 V ! 96 00 35 69
AP51.65.35.3 3 x 460 V ! 96 00 35 70

AP51 Vortex impeller


Control box
Pump type Voltage with 0.8 m Level switch 10 m cable Product no.
supply cable
AP51.65.14.1.V 1 x 230 V ! ! 96 00 34 78
AP51.65.14.A1.V 1 x 230 V ! ! ! 96 00 34 79
AP51.65.14.3.V 3 x 230 V ! 96 00 34 80
AP51.65.14.3.V 3 x 380 V ! 96 00 34 81
AP51.65.14.3.V 3 x 460 V ! 96 00 34 82
AP51.65.15.3.V 3 x 230 - 380 V ! 96 00 34 83
AP51.65.15.3.V 3 x 460 V ! 96 00 34 84
AP51.65.23.3.V 3 x 230 - 380 V ! 96 00 34 85
AP51.65.23.3.V 3 x 460 V ! 96 00 34 86
AP51.65.34.3.V 3 x 230 - 380 V ! 96 00 34 87
AP51.65.34.3.V 3 x 460 V ! 96 00 34 88
AP51.65.35.3.V 3 x 230 - 380 V ! 96 00 34 89
AP51.65.35.3.V 3 x 460 V ! 96 00 34 90
AP51.65.36.3.V 3 x 230 - 380 V ! 96 00 34 91
AP51.65.36.3.V 3 x 460 V ! 96 00 34 92

63
Product range AP80, APG

AP80
Pump type Voltage 10 m cable Product no.
AP80.100.15 3 x 230 V ! 96 00 45 00
AP80.100.15 3 x 380 V ! 96 00 45 01
AP80.100.15 3 x 400 V ! 96 00 45 02
AP80.100.15 3 x 460 V ! 96 00 45 03
AP.80.100.21 3 x 230 V ! 96 00 45 04
AP.80.100.21 3 x 380 V ! 96 00 45 05
AP.80.100.21 3 x 400 V ! 96 00 45 06
AP.80.100.21 3 x 460 V ! 96 00 45 07
AP80.100.27 3 x 230 V ! 96 00 45 08
AP80.100.27 3 x 380 V ! 96 00 45 09
AP80.100.27 3 x 400 V ! 96 00 45 10
AP80.100.27 3 x 460 V ! 96 00 45 11
AP80.100.35 3 x 230 V ! 96 00 45 12
AP80.100.35 3 x 380 V ! 96 00 45 13
AP80.100.35 3 x 400 V ! 96 00 45 14
AP80.100.35 3 x 460 V ! 96 00 45 15
AP80.100.47 3 x 230 V ! 96 00 45 16
AP80.100.47 3 x 380 V ! 96 00 45 17
AP80.100.47 3 x 400 V ! 96 00 45 18
AP80.100.47 3 x 460 V ! 96 00 45 19
AP80.100.65 3 x 230 V ! 96 00 45 20
AP80.100.65 3 x 380 V ! 96 00 45 21
AP80.100.65 3 x 400 V ! 96 00 45 22
AP80.100.65 3 x 460 V ! 96 00 45 23
AP80.100.74 3 x 230 V ! 96 00 45 24
AP80.100.74 3 x 380 V ! 96 00 45 25
AP80.100.74 3 x 400 V ! 96 00 45 26
AP80.100.74 3 x 460 V ! 96 00 45 27
AP80.100.87 3 x 230 V ! 96 00 45 28
AP80.100.87 3 x 380 V ! 96 00 45 29
AP80.100.87 3 x 400 V ! 96 00 45 30
AP80.100.87 3 x 460 V ! 96 00 45 31
AP80.100.107 3 x 230 V ! 96 00 45 32
AP80.100.107 3 x 380 V ! 96 00 45 33
AP80.100.107 3 x 400 V ! 96 00 45 34
AP80.100.107 3 x 460 V ! 96 00 45 35

APG
Control box
Pump type Voltage Level switch 10 m cable Product no.
with 0.8 m supply cable
APG.50.12.1 1 x 230 V ! ! 96 00 35 16
APG.50.12.A1 1 x 230 V ! ! ! 96 00 35 17
APG.50.11.3 3 x 230 V ! 96 00 35 84
APG.50.11.3 3 x 380 V ! 96 00 35 85
APG.50.11.3 3 x 460 V ! 96 00 35 20
APG.50.18.1 1 x 230 V ! ! 96 00 35 21
APG.50.18.A1 1 x 230 V ! ! ! 96 00 35 22
APG.50.19.3 3 x 230 - 380 V ! 96 00 35 23
APG.50.19.3 3 x 460 V ! 96 00 35 24
APG.50.30.1 1 x 230 V ! ! 96 00 35 25
APG.50.30.A1 1 x 230 V ! ! ! 96 00 35 26
APG.50.29.3 3 x 230 - 380 V ! 96 00 35 27
APG.50.29.3 3 x 460 V ! 96 00 35 28
APG.50.33.1 1 x 230 V ! ! 96 00 35 29
APG.50.30.A1 1 x 230 V ! ! ! 96 00 35 30

64
65
66
67
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

V7 11 82 80 03 03