TEST REPORT

IES LM 79-08
Electrical and Photometric Measurements of Solid- State Lighting Products
Report Reference No. ...................... :
Date of issue .................................... :
No. of Pages
Testing Laboratory Name .............. :
Address ............................................ :
Manufacturer’s Name .................... : Sandeep Traders
Address ............................................ : New Delhi
Applicant’s Name ........................... : Sandeep Traders
Address ............................................ : New Delhi
Test Report Form No. .................... :
Test Report Form(s) Originator .... :
Master TRF………………………….:

Test item description LED Module


Trade Mark

Manufacturer Sandeep Traders

Model/Type reference Module

Ratings 12Vdc

Approved by / Authorized
Tested by: Issued by:
Signatory:
COPY OF MARKING PLATE

Please Provide
Table – List of Attachments

Attachment No. Attachment Description Page No.


Attachment – 1 Luminous Intensity Distribution Curve 6
Attachment – 2 Spectral Power Distribution 7
Attachment – 3 Photograph of the sample 8

Testing ..........................................................................:
Date of receipt of test item .........................................: 06/06/2023
Date(s) of performance of tests ........................... ….: 06/06/2023

Physical Condition of sample…………………………: Good

Laboratory conditions…………………………...……..:

Ambient Temperature…………………………..………: (25 ± 1)˚C

Ambient Humidity………………………………...……..: (60 ± 15)% RH

Details of Test Equipment Used

Equipment Calibration status

S.
Equipment
No Equipment Detail Calibration status Valid up to Traceab
Model ID
. ility
C Type Gonio-photometer –
GO-R5000 with total Spectral Upto 100
1. Radiant Flux Lamp D908S CTL-584 Valid hours of NIST
(90.97V,7.1675A,omni- burning
directional`)

2. Digital Power Meter PF310 CTL-584 Valid 25.03.2024 NPL,


India
Details of Tests Performed and Result

Sl. Test Parameter IES No. and Cl. No.


No.
1. Input DC Voltage IES LM79-08/Cl. No.: 8.0
2. Input DC Current IES LM79-08/Cl. No.: 8.0
3. Input DC Power IES LM79-08/Cl. No.: 8.0
4. Power factor As per customer’s request
5. Frequency IES LM79-08/Cl. No.: 8.0
6. Total Luminous Flux IES LM79-08/Cl. No.: 9.0
7. Luminous Intensity Distribution IES LM79-08/Cl. No.: 10.0
8. Luminous Efficacy IES LM79-08/Cl. No.: 11.0
9. Chromaticity Coordinates IES LM79-08/Cl. No.: 12.0
10. Correlated Color Temperature IES LM79-08/Cl. No.: 12.0
11. Color Rendering Index IES LM79-08/Cl. No.: 12.0

General remarks:

1. The test results presented in this report relate only to the object tested.
2. This report shall not be reproduced, except in full, without the written approval of the issuing testing
laboratory.

Throughout this report a comma / point is used as the decimal separator.


Discipline: Photometry
Group: Luminaires

Clause No
Test / Requirement name Test result/
observation
8.0 Electrical Instrumentation
The Electrical Characteristics measured for DC Powered SSL Products are
1. Input DC Voltage 11.83 V
2. Input DC Current 0.0914A
3. Input DC Power 1.081 W
4. Power Factor 1
5. Frequency DC Supplied
9.0 Total Luminous Flux 106.89 lm
10.0 Luminous Intensity Distribution Attached as
Attachment 1
11.0 Luminous Efficacy 98.88 lm/W
12.0 Color Characteristics (Average) x꞊0.3201,
1. Chromaticity Coordinates y꞊0.3428
2. Correlated Color Temperature (Average) 6056K

3. Color Rendering Index (Average) 85.3

Supplementary Information:

1. The sample is tested according to IES LM 79-08.


2. Photometric parameters are obtained using C-type Goniophotometer and software.
3. The sample has been operated at DC 12V.
4. The sample has been operated for 45 minutes prior to measurement for a stable condition and total
Measurement time is 95 minutes.
5. The orientation (burning position) of SSL product during test is its normal burning position.
6. The test distance is greater than 5 times the maximum light emitting area.
7. Total Spectral Radiant Flux Lamp, D908S of 600W (omni-directional) and NVLAP calibrated (NIST
traceable) has been used as Standard Lamp.
Attachment-1

Luminous Intensity Distribution Curve


Attachment-2

Spectral Power Distribution


Attachment-3
Photograph of the sample

Front View

****END OF THE TEST REPORT****