Catalog 101

04/2021

Optional Extras and Enclosures


Kraus & Naimer
The development of the Blue Line rotary switch and motor starter
product ranges is based on more than hundred years experience by
Kraus & Naimer in the design and manufacture of electrical switchgear.
Kraus & Naimer pioneered the introduction of the cam operated rotary switch
and continues to be recognized as the world leader in that product field.

BLUE LINE
Blue Line products are protected by numerous patents through-out the
industrial world. They are built to national and international standards and
designed to withstand adverse temperatures and climates.

Blue Line products are accepted and universally recognized for


their quality and workmanship. They are supported by a worldwide
sales and service organization.

The Kraus & Naimer Registered Trademark

WORLDWIDE SYMBOL
FOR QUALITY SWITCHGEAR
Disconnectors and Main Switches with Optional Extras acc. to IEC 60947-3 see Catalog 500

Contents Description Dimensions


Page Page

Construction Data 4 -

How to order 5 -

Optional Extras:

Add-on Face Plates 24 41

Auxiliary Contacts 10 29
Bayonet/Switch Coupling 13 34

Control and Indicator Lamp Devices 9, 10 29


Door Clutches 7, 8 28, 31

Electromechanical Interlock 12 33
Ground and Neutral Terminal 13 35

Indicator Lamp Devices 10 31


Interlock between Switches 11 32

Key-lock Devices 17-20 36-39


Motor Drive 16 35

Padlock Devices 21 39, 40


Protective Cover 13 -

Push Button Interlock 12 33


Push-pull Interlock 11 32

Ratchet Coupling 15 34
Shaft Extension 6 28

Slip Clutch 15 34
Special Drive Units 14 35

Spring Return over several Positions 15 31


Stop and Go Device 11 31

Tandem Drives 13 32
Terminal Lugs 6 -

Trip Devices 16 34
Trip Indicator 8 -

Uni-directional Interlock 15 -

Switch Type Variations 23 40, 41

Enclosures 25-27 42-44

Blue Line Switchgear:


Summary 46 -
Construction Data

The large cam switch line of the A, C, CA, CAD, CG, CH, CHR, D, L and X-series is complemented by a large
number of optional extras and enclosures.
This substantial number of optional extras and enclosures is needed in order to meet the requirements of the world
market.

One or more optional extras may be used in


combination with any one switch provided they
are of the same switch size. A few exceptions
where this cannot be accomplished are noted on
the following tables. In some cases, for technical
strength or esthetic reason, it may be desirable
that a switch be combined with an optional feature
of the next larger switch size. Many options provide
for such a possibility.

< back to table of contents >


Enclosures are manufactured from plastic or alu-
minum material. They offer a high degree of pro-
tection (up to IP 66/67) thereby permitting switch
operation under adverse environmental condi­
tions. All KL- and KS-enclosures are flame resis­
tant in accordance with UL94V-0. The materials
used provide considerable strength and the best
possible protection against corrosion. A large
number of possibilities exist for combining swit-
ches, enclosures and appropriate optional extras.

4
How to order
Disconnectors and Main Switches with Optional Extras acc. to IEC 60947-3 see Catalog 500

When ordering Blue Line cam switches with optional extras, the following method of coding is required. Details on the enclosures and optional
extras are shown in this catalog.

1. Switch Type 2. Switch Function 3. Type of Mounting

See Catalog 100, 110, 120, 130 or See Catalog 100, 110, 120, 130 or See Catalog 100, 110, 120, 130 or
DC-Switch G20/G20S. DC-Switch G20/G20S. DC-Switch G20/G20S.

4. Enclosures

The assigned code numbers for the various


enclosures are shown in this catalog on
pages 25-27.

CA20B A202 PN
V840G/
< back to table of contents >

5. Optional Extras

Pages 6-24 list optional extras and their coding. A indicates the switch sizes in which the optional extra shown is available.

Possible combinations of switches of the same switch size with an optional extra of the next larger switch size are indicated by a .
Only in this case indicate the next larger switch size in front of the coding.

There are some optional extras in existence which are available in a variety of programs. Additional ordering data may, therefore, be required.
In the above case, a color description is required for the cover and handle disc.

Switch Size of Switch Size of Switch Size of Switch Size of


Types Mounting Types Mounting Types Mounting Types Mounting

A11 S1 CA10R S0 CH10B S1 DHR12 S0


A11C S2 CA10B S1 CH16 S0 DH12B S1
A25 S1 CA11 S0 CH16B S1 DHR12B S1
A25C S2 CA11B S1 CHR6 S00 G20 S0
C26 S1 CA20 S0 CHR10 S0 G20S S0
C26C S2 CA20B S1 CHR10B S1 L350 S2
C32 S1 CA25 S0 CHR16 S0 L351 S2
C32C S2 CA25B S1 CHR16B S1 L400 S3
C42 S1 CA40 S1 DK10 S0 L600 S3
C43 S2 CA50 S1 DH10 S0 L630 S2
C80 S2 CA63 S1 DHR10 S0 L631 S2
C125 S2 CAD11 S0 DH10B S1 L800 S3
C200-4 S2 CAD12 S0 DK11 S0 L1000 S2
C315 S3 CG4 S00 DH11 S0 L1200 S3
C316 S3 CG4-1 S00 DHR11 S0 L1600 S3
CA4 S00 CGD4-1 S00 DH11B S1 L2000 S3
CA4N S00 CG6 S00 DHR11B S1 X200 S3
CA4-1 S00 CG8 S0 DK12 S0 X400 S3
CAD4-1 S00 CH6 S00 DKR12 S0 X630 S3
CA10 S0 CH10 S0 DH12 S0

5
For Switch Sizes
Optional Extras Code
S00 S0 S1 S2 S3

Terminal Lugs

For screw with wire clamps M900 G20 A11


G20S A25
Terminal lugs facilitate the connecting of wires in C26
installations where the terminals are not easily C32
accessible. C42
All X switches, L switches and switches type C315/
C316 will be supplied with terminal lugs as standard.

1 1 1

Terminal lugs for quick connect termination M930 CA4 CH10 A11
CH6 CH16 A25
Each quick connect terminal may accept either one DH10 CH10B
6,3 mm quick connect lug or two 2,8 mm quick con- DK10 CH16B
nect lugs. Switch type CA4 only accepts one quick G20 DH10B
connect lug 2,8 mm. G20S

< back to table of contents >


Shaft extension

With asymmetric profile

Shaft length not adjustable L100


L100B

Shaft with unlimited adjustable length M004D


with set screw
with shear ring

Dimensions p. 28
Adjustable shaft can be set to the desired length in
a pre-mounted switch with VE mounting plate.

With square profile

Shaft length not adjustable  6 mm L100A


 5 mm L105A

Shaft with unlimited adjustable length M004E


with set screw
with clamping bushing
Dimensions p. 28

Ordering data: Free shaft length or dimension from mounting


surface to cover.
1
The coding of the switch type may change as shown in Catalog 100, 120 and 130, page 6.
6
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Standard Door Clutch



With shaft extension, shaft with unlimited
adjustable length
shaft fixation with set screw M280E
Front protection IP 40 M280E/.EF
Front protection IP 66/67


Dimensions p. 30

1
Door clutches M700/M701

For 3 padlocks mm 4‑8

Handle lockable with padlocks M700


Protection IP 66
The face Plate is available in black, yellow and alu.

The handle may be supplied in black and red.


Standard handle and standard face plate M701
Protection IP 65
< back to table of contents >



The M700/M701 is a padlock door clutch and a mechanical
interlocking safety device. Using the device the electrical panel
may be opened only when the switch is in the OFF position and
no padlock is fitted. Note: Only in the ON position can knowledge-
Dimensions p. 30
able personnel using a simple tool to defeat the interlock. The
M700’s flexibility allows for successful installation with as much
as + or - 5 mm of misalignment between the shaft and door.


Unlock insert for the M700 ff. S1D M700 29
To open the door in ON-position. (After the locking has been
made inactive, it is necessary to take effective precautions
against an opening of the door by unauthorized persons.)


Door clutches M800/M810.1
For 3 padlocks

Door clutch utilizes a simple and robust design and features a


compact size. It has an interlock in the ON-position while a mm 5 ‑ 7,5

padlock can be fitted in the OFF-position. The door clutch M800


may be opened only if the switch is in the OFF-position. In
special cases, however, authorized people have a require-
ment to open the door, even if the switch is in the ON-position.
Further characteristics are the single hole mounting with
IP 66/67 protection degree, as well as the Accepted Misalign-
ment up to ± 3 mm horizontally and ± 5 mm vertically. Maxi-
mum 3 padlocks with a minimum shackle diameter from 5 up M810
to 7,5 mm are possible.
Dimensions p. 30

Ordering data: Dimension from face of the switch to the cover or dimension
from mounting surface to cover as well as the interlock
program and the color selection.
1
Additional shaft extension must be specified.
7
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Simplified Door Clutch

Single hole mounting 22 mm, protection IP 66.



Additional profile extension parts and shaft extension must
be specified.

For shaft extension M295/.A
For profile extension parts M295/.B


With padlock device and single hole moun-
ting 22 mm, protection IP 66.

Additional shaft extension must be specified.
mm 6‑8
For 2 padlocks V840E
mm 6 ‑ 6,5
For 2 padlocks V840D
mm 7‑8
For 3 padlocks V840G
mm 4‑7
For 4 padlocks V840F
The cover disc is available in black, yellow and electro-gray.

< back to table of contents >


The handle may be supplied in red, black and electro-gray.

mm 3 - 7 4 ‑ 7,5
Up to 4 padlocks
V845
Operation of the locking bar from the front.
Available in black, red and electro-gray.


Centering aid for simplified door clutches with M600


single hole mounting and shaft extension

Misalignment between the shaft and mounting are compen-


sated in all 4 directions.

Dimensions p. 29

Ordering data: Free shaft length or dimension from mounting surface to cover
or distance from face of the switch to the cover and color selection.

Trip Indicator

With square face plate M120/A

With rectangular face plate M120/B

The trip indicator used on switches with spring return posi-


tions. It includes a colored indicator to show the last spring
return position that handle has been turned.
Two possibilities for flag indicator exist:
a) left red - right green
b) left green - right red

Ordering data: The color to appear after left or right operation.

8
For Switch Sizes
Optional Extras Code
S00 S0 S1 S2

Control and Indicator Device (without Lamp)

For 1 lamp with BA9s socket


Max. power 2 W, Protection IP42

The control and indicator device with total switching angle


Q1201
of 360° includes a single hole mounting 22/30 mm
with locking nut and can be mounted and dismounted with­
out tools.

The following front end assemblies are available:


Dimensions p. 29 - Front ring (alternatively with add-on face plate)
- Face plate 48 x 48 mm
(alternatively with add-on face plate)
- Face plate 64 x 64

The operation may be as follows:


- Turn to operate
Q120/F1
- Push-to-turn operation (e.g. discrepancy switch Q120/F)
The push-to-turn version is available with 1 or 2 auxiliary
contacts and a mechanical interlock. Select between a
contact system with rigid contact bridge for excellent AC-15
making and breaking capabilities. Also available with gold
contacts for use in aggressive envi-ronments. Or select a
H-bridge design with „cross-wire“ gold-plated contact
system for low voltages and currents.
< back to table of contents >

LED-lamps with 4 chips and


integrated bridge rectifier, BA9s socket
Colour Voltage Article Number
white P SN/LW024
red 24 V–28 V AC/DC P SN/LR024
green P SN/LG024
white P SN/LW220
red 220 V AC/DC P SN/LR220
green P SN/LG220
white P SN/LW110
red 110 V–120 V AC/DC P SN/LR110
green P SN/LG110

Ordering data: Front end assembly + function of the mechanical interlock,


quantity and operation of the auxiliary contacts and type of
the contact system.
1
Ambient temperature: 35 °C during 24 hours with peaks up to 40 °C

Control and Indicator Device with Light Conductor

The luminous source is a LED module with yellow light-


emitting diode mounted at the end of the switch. Q100B
The transmission of light occurs via a light conductor.
Technical Data:
Voltage Frequency Power Consumption
24 V AC 50 - 60 Hz, DC 0,2 W
48 - 60 V AC 50 - 60 Hz 0,3 W
48 - 60 V DC 1W
110 - 120 V AC 50 - 60 Hz 0,3 W
110 - 120 V DC 1,4 W
220 - 240 V AC 50 - 60 Hz 0,3 W
with test terminal:
24 V DC 0,2 W
48 - 60 V DC 1W Q100B *E
110 - 120 V DC 1,4 W

Types of version
Without interlock (handle “turn to operate“)
With interlock (handle “push to turn“)
Dimensions p. 29
The control and indicator device is available for single hole
mounting and mosaic.

Ordering data: Operating voltage and type of version.

9
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Control and Indicator Device (without Lamp)

Dimensions p. 29
For 6 lamps with socket T6,8
Length of lamp 42-44 mm
Q100/A
Max. power per lamp 2,5 W

According to the operating voltage the lamps have to be


paralleled or connected in series. As front end assembly an
alu-face plate 51,8 x 51,8 mm is supplied.

Indicator Lamp Device (without Lamp)

With square face plate

With white lamp socket1 Q200/A1


Without lamp socket Q200/A2

The lamp socket for switch size S0 had been designed for
glowing lamps with socket E10.
Dimensions p. 31
For switches size S1, S2 and S3 the sockets are provided
for lamps with thread E14.

With rectangular face plate

< back to table of contents >


With white lamp socket1 Q200/B1
Without lamp socket Q200/B2
1
Additional colors on request.

Auxiliary Contacts

These auxiliary contacts are controlled with a cam which


can be programmed. The max. number of the auxiliary con-
tacts for switches of size S1 and S2 is 4 pcs. and for swit-
ches of size S3 is 6 pcs.
Select between a contact system with a rigid bridge for
excellent AC-15 making and breaking capabilities or a
H-bridge design with “cross-wire“ contacts (sizes S1 and
S2) for low voltages and currents. The contact systems with
gold contacts or gold-plated contacts allow for use in A11 C80
Dimensions p. 29 aggressive environments also. A25 C125
In cases where more than 4 resp. 6 auxiliary contacts are M510B CA40 L350-
required, an auxiliary switch should be used alternatively. CA50 L1000
CA63
Size S1 S2 / S3 C26
Rated Insulation Voltage Ui V 440 690 C32
Rated Thermal Current Iu/Ith A 10 16 C42
Switching of resistive loads,
AC-21 A 10 16
including moderate overloads

110 V-240 V A 2,5 6


Switching of control devices,
AC-15 380 V-440 V A 1,5 3
contactors, vales etc.
500 V A - 1,5

Short Circuit Protection


Max. fuse size gG-charakteristic A 10 10

Max. Permissible Wire Gage - copper wires only

single-core or stranded wire mm2 1,5 2,5


2
Flexible wire mm 1,5 2,5

Flexible wire with sleeving in 2


mm 1 2,5
accordance with DIN 46228

Ordering data: Quantity and operation of the auxiliary contacts and type of
the contact system.

10
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Push-pull Interlock

To pull lateral spring return V110A


To pull lateral latching V115A
To push lateral spring return V130A
To push lateral latching V135A

The push-pull device is used to interlock the switch so that


Dimensions p. 32 the handle can be rotated only when pushed or pulled. The
push-pull device can be programmed to allow the interlock
to operate only between pre-determined switch positions.
220 V-240 V 2,5 A
Auxiliary contacts can be operated by means of the axial
AC-15
380 V-440 V 1,5 A movement of the handle. For switches size S0 the max.
number of auxiliary contacts is 2 pieces for all other sizes
8 pieces. In addition switches size S0 can also be combined
Dimensions p. 32 with a trip indicator.

To pull lateral spring return V110


To pull lateral latching V115
To pull and to push lateral spring return V120
< back to table of contents >

To push lateral spring return V130


240 V 6A
AC-15
500 V 3A To push lateral latching V135

Ordering data: Description of the interlocking program, number and


operation of the auxiliary contacts.

Stop and Go Device

The stop and go device prevents a fast switching thru the V160
center OFF position. This is only possible with a 60°
switching angle.
The stop and go device only becomes activated in the
center switch position, in either in both or one direction.

Dimensions p. 31

Ordering data: Operation of the stop and go device.

Interlock between Switches

For 2 switch columns V600/B

An interlock between 2 or 3 switch columns permits the


operation of one switch only when the other switch or
switches are located in a pre-determined switching position.
For heavy duty service reinforced devices are available.

Dimensions p. 32 For 3 switch columns V600/C

Ordering data: Description of the interlocking program.

11
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Push Button Interlock

With square face plate

Switching only possible if push button is pressed. V400/A1 1

Up to 4 auxiliary contacts can be operated by pressing the


push button.

With rectangular face plate

Switching only possible if push button is pressed. V400/B1 1

< back to table of contents >


Dimensions p. 33

Ordering data: Number and operation of the auxiliary contacts.

Electromechanical Interlock 2

For switches size S1

The electromechanical interlock locks the switch in any


switching position. The interlock device is operated by
energizing or de-energizing the electromechanical system.
Adding auxiliary contacts to the switch permits the device
to be operated only in pre-determined positions. V140

The optional extra S1 V140/2 can be equipped with a posi-


tive breaking auxiliary contact according to IEC 60947-5-1

24 V - 600 V 50 Hz/60 Hz
11 W Power Consumption

For switches size S2 and S3 or for switches V140


size S1 with DC solenoid


Magnet S1E V140/
available Voltage:
24 V - 240 V 50 Hz/60 Hz /DC
Dimensions p. 33 20 W Power Consumption

Ordering data: Advise if the interlock is activated either by energizing or


de-energizing of the electrical system. Coil voltage also
required.
1 2
With auxiliary contacts available only up to switch type CA25B. Ambient temperature: 35 °C during 24 hours with
12 peaks up to 40 °C.
For Switch Sizes
Optional Extras Code
S00 S0 S1 S2 S3

Protective Cover

The protective cover prevents accidental contact M160 C26 C80 C315
with current-carrying terminals. C32 C125 C316
C42 L400
A25

Ground and Neutral Terminal

H040/E
Ground terminal
H040/N
Neutral terminal
H040/NE
Ground and neutral terminal
< back to table of contents >

Dimensions p. 35

Tandem Drive

For 2 switch columns M300/B

Two or three switch columns can be operated simul-


taneously.
Special programs are available to reinforce the device
for heavyduty applications.

For 3 switch columns M300/C


For 4 switch columns M300/D

Dimensions p. 32

Bayonet/Switch Coupling

The device is used to couple switches


into one column

Switches of the same size M270

Switches of different sizes M275

Dimensions p. 34

13
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Special Drives

Heavy duty drive unit G800/A

The device is designed to allow customer to couple his own


operating device to the switch.

Dimensions p. 35

Heavy duty drive unit with actuator and roller G800/B

< back to table of contents >


Dimensions p. 35

Double action lever G800/C

Dimensions p. 35

Rope operation G900/B

Available for spring return, maintained or stepping operation.

Dimensions p. 35

14
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Spring Return over several Positions

Spring return from both sides M470/A

Spring return from one side M470

Spring return for angular displacement up to 30° can be


accomplished by using the latching mechanism only. If a
large number of contacts must be opened simultaneously
or a total angular displacement is larger than 30° over
which the spring return is operational, the switch must use
one of the spring return devices.
Spring return from both sides can be designed to permit
Dimensions p. 31
maintained position on each side of center.

Ordering data: For M470, specify spring return from either left or right side
and details of maintained positions, if required.

Uni-directional Interlock
< back to table of contents >

The uni-directional interlock prevents the switch from being


operated counterclockwise. The interlock may be in either M400
all positions or in pre-determined positions only.

Ordering data: Specify which positions should be interlocked.

Slip Clutch and Ratchet Coupling

Slip clutch M200

Using the slip clutch, two cam shafts can be coupled in


such a way so that the secondary cam shaft will operate
only after the primary cam shaft has been moved over a
pre-determined angle. This slip clutch allows e. g. the de-
energized changing back of switches for pole-changeable
motors. Not available for D-switches.

Dimensions p. 34
Ratchet coupling
M230 CA40
A ratchet coupling attaches to the rear of the switch. CA50
Additional stages are then attached behind the coupling CA63
device which serves to operate that portion of the switch C26
only when the handle is turned counterclockwise. When the C32
handle is turned clockwise, the rear switch portion remains
in the same position.

15
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Electromechanical Trip Device (Undervoltage Release) 1

Operating voltage and frequency:

AC/50 Hz V350/A

AC/60 Hz V350/B

AC/50/60 Hz V350/C

DC V350/D

The device includes a magnetic system which releases the


switch to the trip position at voltage failure or undervoltage
of 70 % of the nominal voltage. The device is trip-free, in
that the switch can be operated only when the primary
voltage is available. When using DC voltage, an economy
Dimensions p. 34
resistor must be provided.
Switches with integrated undervoltage release are descri-
bed on page 23.

< back to table of contents >


Ordering data: Operating voltage and frequency for the magnetic system.

Electromechanical Trip Device (Shunt-trip) 1

The device permits the switch to be turned to the trip V360/A


position by remote control. The coil is designed for short-
time duty requiring an auxiliary contact in the switch which
de-energizes the coil in the trip position.

Controlling of the magnetic system:


24 V-440 V/50 Hz, 60 Hz or DC

Dimensions p. 34

Ordering data: Operating voltage for the magnetic system.

Motor Drive 1

The motor drive consists of an AC motor with capacitor,


gear train and Geneva gear. This device allows switches to R300
be operated from a remote location. Motor voltages avai-
lable are 230 V, 50 Hz and 117 V, 60 Hz.
Possible control systems:
- Follow-up control
- Impulse control
Further information as well as special control systems
upon request.
Dimensions p. 35

1
Ambient temperature: 35 °C during 24 hours with peaks up to 40 °C.
16
For Switch Sizes
Optional Extras Code
S00 S0 S1 S2

Key Lock device

For 1 stage switches in PN enclosure V750/ CA11


CA20

For 2 stage switches in PN enclosure CA10-


CA20

Dimensions p. 36

For 1 stage switches with plaster depth trim CA10


(With half-cylinder see page 19)

Dimensions p. 36

For base mounting with type of mounting VE21 V750D/ CA4


CG4
< back to table of contents >

For single hole mounting combined


with 16/22 mm, protection IP 66/67/69k

Dimensions p. 36 Micromec lock V750D/5


With front ring (mounting FS1)
Face plate 30 x 30 mm (mounting FS2)
Face plate 30 x 39 mm (mounting FS4)
Locking program in which the key can be removed:

Dimensions p. 36

1
Lock 601 V750D/2
With front ring (mounting FS1)
Face plate 30 x 30 mm (mounting FS2)
Face plate 30 x 39 mm (mounting FS4)
Locking program in which the key can be removed:

Dimensions p. 36

For single hole mounting combined with 22 mm, V750D/3


protection 66/67/69k
With front ring (mounting FT1)
Face plate 48 x 48 mm (mounting FT2)
Face plate 64 x 64 mm (mounting FH3)
Face plate 48 x 59 mm (mounting FT6)
Face plate 64 x 78,5 mm (mounting FH4)
Locking program in which the key can be removed:
Dimensions p. 36

Ordering data: Locking program of the key.

1
At high safety requirements use V750D/1.
17
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Key-lock Device with Kaba Lock

For single hole mounting 25 mm

With front ring (mounting EL) V750D/

Dimensions p. 37

For four hole panel mounting

Face plate 48 x 48 mm (mounting E) V750D/A


Face plate 64 x 64 mm (mounting EG) V750D/A
Face plate 48 x 60 mm (mounting E) V750D/B
Face plate 64 x 78,8 mm (mounting EG) V750D/B

For snap-on base mounting


Dimensions p. 37
on track acc. to EN 50022 V750D/

< back to table of contents >


With face plate for 45 mm knock-out (mounting VE2)

Locking program in which the key can be removed:

Dimensions p. 37

Ordering data: Locking program of the key.

Key-lock Device with Profile Cylinder

The key-lock device V750E with profile cylinder is furnished


with a single hole mounting 22 mm for switches in size S0. The
key can be removed in one switch position or for switches with
60° switching angle in up to six switch positions. The device V750E
with profile cylinder can be supplied with standard lock cylin-
ders manufactured by CES, BKS or IKON.
Dimensions p. 37

18
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Key-lock Device with Kaba Lock

For single hole mounting 40 mm

Face plate 64 x 64 mm (mounting EL2) V750/A1


With front ring (mounting EL1)

Key can only be removed in the 12 o’clock position.


Central locking systems are available.
Dimensions p. 38

Key-lock Device with Half-cylinder Lock

For switches with plaster depth trim V755.UE1 BA20


< back to table of contents >

For 1 stage switches in standard flush mounting box


For multiple staged switches in special flush mounting box
Protection IP 42

The switch must have an arrested position in 12 o’clock. The


key is only removable in the 12 o’clock position. The max.
Dimensions p. 38
angular displacement is 2 x 135°.

Dust cap for key-lock device S0D V755 12


Protection IP 43

For panel mounting V755.E


Protection IP 42

The key is removable in the 12 o’clock position. The max.


angular displacement is 2 x 120°.
Protection IP 42

Additional programs with key removable in 2 positions are


Dimensions p. 38 available on request.

19
For Switch Sizes
Optional Extras Code
S0 S1 S2 S3

Safety-key-lock Device with separate Drive

With small cylinder lock

Square face plate V760/A.E

Rectangular face plate V760/B.E


Dimensions p. 38

With commercial half-cylinder lock

Square face plate V760/A

Rectangular face plate V760/B

Dimensions p. 38

With half-cylinder lock

< back to table of contents >


Square face plate V765

Dimensions p. 38

With dust cap


Protection IP 43

Dimensions p. 38

Various key positions and locking programs are available.


Key positions:
Key can be removed in locked and unlocked positions.
Key can be removed only in locked positions.
Locking programs:

Locking Switching Switch Positions Size


Program No. Angle To be locked Not to be locked
1 30°-90° one the balance S0-S3
20° S1, S3
2 all none
30°-90° S0-S3
3 30°-90° the balance one S1-S3
1
4 30°-90° one 1
the balance 1
S0-S3

1
Locking program 4 permits the locking of the device in any switch position. However, the actual
locking becomes effective in a pre-determined switch position only.

Ordering data: Advise locking program and positions in which the key can
be removed.

20
For Switch Sizes
Optional Extras Code
S00 S0 S1 S2 S3

Padlock Device

For 1 padlock mm 3,5 ‑ 5


with lock bow diameter for 4-5,5 mm.
V840K
The handle may be supplied in black and red.





Dimensions p. 39








mm 3,5 ‑ 4,5 4‑6
The padlock is an integral part of the switch
V840A/A
handle itself and can hold 2 padlocks

The lock bar is accessible from the bottom. Handle can be
mm 3‑4
sealed in the locked and unlocked positions. The handle
< back to table of contents >

V840A/C
may be supplied in black, red and electro-gray.


Dimensions p. 39







For 1 padlock mm 4,5 ‑ 6
For mounting VE2 and VE21 with lock bar accessible from
V840B
the front. Available in red and electro-gray.



Dimensions p. 39

Up to 4 padlocks
mm
3 - 7 4 - 7,5 4 - 8 4 - 8,5
The lock bar is accessible from the front and may be
supplied in black, red and electro-gray. V845

Spring loaded push rod mm 4 ‑ 7,5


Dimensions p. 39
Up to 4 padlocks V846


Ordering data: Color variation.

21
For Switch Sizes
Optional Extras Code
S00 S0 S1 S2 S3

Padlock Device

Padlock device with integrated


F- or B-handle
The cover disc is available in black, yellow and electro-
gray. The handle may be supplied in black, red and electro-
gray.

For 2 padlocks mm 3‑7

Dimensions p. 39 V840D

For 3 padlocks mm 4‑8

With F-handle V840D



For 3 padlocks mm 7‑8

With F-handle V840G

For 3 padlocks mm 7‑8

With B-handle V840G/B


Dimensions p. 39

< back to table of contents >


mm 4‑7
For 4 padlocks
V840F/F
With F-handle
mm 4‑7
For 4 padlocks
V840F/B
With B-handle
Dimensions p. 39


mm 3 - 5,5 4- 7,5 4- 7,5
For 2 padlocks V850
For 3 padlocks
For 6 padlocks

Upon request, the device can be programmed to lock in


several switch positions.

Dimensions p. 40


Padlock device for C switches with base mm 3‑8
mounting for locking when control cabinet is V841
opened.

Padlock device with simplified door clutch and single


Dimensions p. 40
hole mounting see page 8.

mm 3‑8

V842

Dimensions p. 40

Ordering data: Color variation.

22
For Switch Sizes
Switch Type Variations Suffix Code
S0 S1 S2 S3

PFR (Power Failure Release) 1

Size S0 X CA..

The magnetic system includes a low hum DC coil with


incapsulated diode rectifier (blocking voltage 1000 V) = it,
therefore, works independent of frequency. PFR switches
are available with 24 V-600 V coils.
Available switching detents: 1 x 60° (60° to the right of
center OFF), 2 x 60° (60° to the right and left of center OFF).

Dimensions p. 40
Alternatively with trip-free release Y CA..
(Switching angle 1 x 60°) CG8

The PFR switch series is designed to provide protection for


both machines and machine operators by preventing the
equipment (which has been operating) from restarting
automatically after a power failure.
The device includes a magnetic system which releases the
switch (by means of a linear spring return mechanism) to
the trip position at voltage failure or undervoltage of 70 %
of the nominal voltage.

Size S1 X
< back to table of contents >

A25
CA40
Operating voltage for the magnetic system:
24 V-500 V/50 Hz CA50
24 V-600 V/60 Hz CA63
Dimensions p. 40 C26
(Switching angle 1 x 60°) C32
C42
Ordering data: Operating voltage for size S0 as well operating voltage and
frequency for size S1 for the magnetic system.

Lockout-relay 1

With manual release M CA10 A11


CH.. A25
The lockout-relay is typically used to remotely switch CA40
electrical circuits from one power source to another. CA50
CA63
The device contains a totally incapsulated coil and linear C26
spring return mechanism which is compressed by manual- C42
ly turning the handle to the ON position (60° to the right of
OFF). Once in the ON position, the handle is mechanically
locked in place and cannot be manually turned back to
OFF. When the coil is energized, however, the unit will
automatically spring return to the OFF position.

Dimensions p. 41 A second version is available with push button manual


release for test purposes.

Technical Data:
Voltage Frequency Power Consumption
24 - 28 V AC 50 - 60 Hz, DC 135 VA
32 - 40 V AC 50 - 60 Hz, DC 145 VA
42- 50 V AC 50 - 60 Hz, DC 155 VA
60 V AC 50 - 60 Hz, DC 165 VA
110 - 125 V AC 50 - 60 Hz, DC 185 VA
220 - 240 V * AC 50 - 60 Hz, DC 220 VA
380 - 440 V * AC 50 - 60 Hz, DC 240 VA
* for DC on request

Without manual release L CA10 A11


Dimensions p. 41
CH.. A25
CA40
CA50
CA63
Ordering data: Operating voltage and frequency for the magnetic system. C26

1 2
Ambient temperature: 35 °C during 24 hours with peaks up to 40 °C. In preparation.
23
For Switch Sizes
Optional Extras Code
S00 S0 S1 S2 S3

Rectangular Add-on Face plates

Add-on face plates for switches with single hole


mounting and four hole panel mounting

The face plates can be engraved or embossed from the front


or alternatively from the back. Face plates in different height
are also available. The face plate frame is black, the face
plate brushed aluminum. For switch sizes S0, S1, S2 and S3
yellow face plates are also available.

Add-on face plates with black face plate frame,


face plates brushed aluminum

Switches with single hole mounting 22 mm and


front ring

For front inscription F991/A0B/C-PRD


For inscription on the back F991/A0B-PRD

< back to table of contents >


For front inscription F991/A0B/C-PRB
For inscription on the back F991/A0B-PRB

Dimensions p. 41

Switches with single hole mounting or four hole


panel mounting 22 mm and square face plate

For front inscription


For inscription on the back F991/A0B/C-PRC
F991/A0B-PRC

For front inscription


For inscription on the back F991/A0B/C-PRA
F991/A0B-PRA

Face plates brushed aluminum


Dimensions p. 41

For front inscription


For inscription on the back F991/A00/C-P2B
F991/A00-P2B

For front inscription


For inscription on the back F991/A00/C-P2A
F991/A00-P2A

Ordering data: Color variation, if differing from the described version.

24
For Switch Sizes
Enclosures Code
S00 S0 S1 S2

Plastic Enclosures

Enclosure series protection IP 66/67, made of


strong durable plastic, increased wiring space
and cover coupling

KS and KL series
With high UV-resistance, Flammability Standard: UL94 V-0

CS and CL series
For applications in an aggressive environment, such as oil,
chemical substances and grease

Each enclosure has 2 knock-outs on top and bottom for


metric thread according to EN 50262. Standard equipment
includes both a ground and neutral terminal. Size S0
enclosures are also available with lateral conduit knock-out
and a cover interlock which allows for opening without dis-
mantling the handle. They can also be supplied with a
cover locked in 1 position. These enclosures are also avai-
lable for conduit entries for PG-thread.

The following switch types can be mounted:


Switch type Max. no. of stages KS3/CS3 M16
< back to table of contents >

CA4 3
CG4 2
CG6 2

Without cover interlock KS10/CS10 M25


KS50/CS50 M20

With cover interlock (the enclosure can only be KS11/CS11 M25


opened at 9 o’clock position) KS51/CS51 M20

With cover interlock (the enclosure can only be KS12/CS12 M25


opened at 12 o’clock position) KS52/CS52 M20

The following switch types can be mounted:


Switch type Max. no. of stages
CA10 6
CA11, CA20 5
CA25, CG8, CH10-CHR16 4

KL10/CL10 M25
Without cover interlock KL50/CL50 M20

With cover interlock (the enclosure can only be KL11/CL11 M25


opened at 9 o’clock position) KL51/CL51 M20

With cover interlock (the enclosure can only be KL12/CL12 M25


opened at 12 o’clock position) KL52/CL52 M20

The following switch types can be mounted:


Switch type Max. no. of stages
CA10 3
CA11 2
Dimensions p. 42 CA20, CA25, CG8 2
CH10-CHR16 2

25
For Switch Sizes
Enclosures Code
S0 S1 S2 S3

Plastic Enclosures (Front Drive)

Protection IP 65

Conduit entries with metric ISO-thread PF1 M20 M20



PF4 M25

The following switch types can be mounted:


Switch type Max. no. of stages

A11, A25 7

CA10, CA11, CA20, CA25,


CA10B1, CA11B, CA20B, 4
CH10, CH16

CA40, CA50, CA63 6

C26, C42 4

< back to table of contents >


C32 5

Protection IP 42

Conduit entries with metric ISO-thread PN1 M20 M20



PN4 M25

The following switch types can be mounted:


Switch type Max. no. of stages

A11, A25 6

CA10, CA11, CA20, CA25,


CA10B1, CA11B, CA20B, 4
CH10, CH16

CA40, CA50, CA63 6

C26, C32 4

C42 3

Dimensions p. 43
A lamp can be installed on request.

1
Only for 4 stages.
26
For Switch Sizes
Enclosures Code
S0 S1 S2 S3

Plastic Enclosures

Protection IP 44

Conduit entries with metric ISO-thread PK1 M25 M25

Conduit entries without thread PK9

Dimensions p. 44

The following switch types can be mounted:


Switch type Max. no. of stages
A11 12
CA10, CA10R 12
CA11, CA20, CAD11, CAD12 12
CA10B, CA11B, CA20B 12
< back to table of contents >

Aluminum Enclosures

Protection IP 65

Conduit entries with metric ISO-thread GK1 M20 M20


M25
Without conduit entries GK9

The following switch types can be mounted:


Dimensions p. 44
Switch type Max. no. of stages
A11, A25 10
CA10, CA10R 3
CA11 2
CA20 2
CA10B 12
CA11B 10
CA20B 10
CA25B 9
CA40, CA50, CA63 10

Additional conduit entries on request.

27
mm
Optional Extras Dimensions inch

Shaft Extension

L100, L100A, L105A

Size L1 L1 L1 L1 L1 L1 L1 L1 L1 Size D
13,8
S0 19 24 28 32 37 42 47 52 57 S0 .54
18,5
S1 19,8 23,8 27,8 32,8 37,8 42,8 47,8 52,8 57,8 S1 .73
Free shaft length for
L1 L1 L1 L1 L1 L1 L1 L1 L1
E/EF KN1/KD1 KD2 VE
S0 62 67 72 77 82 87 92 97 102
S0 L1-2,3 L1-5,1 - L1
S1 62,8 67,8 72,8 77,8 82,8 87,8 92,8 97,8 102,8
S1 L1-2,5 - L1-2,5 L1

L = Shaft length
M004D, M004E
L1 = Free shaft length max.
1
= Only for square shaft

Size L1 L11 L L1 L L1 L L1 L L1 D1 D2 A SW
60 40 80 60 100 80 120 100 6 13,8 12
S0

< back to table of contents >


2.36 1.57 3.15 2.36 3.94 3.15 4.72 3.94 .24 .54 .47
56,5 20 70 40 90 60 110 80 130 100 8,5 18,5 6 16
S1 2.22 .79 2.76 1.57 3.54 2.36 4.33 3.15 5.12 3.94 .34 .73 .24 .63
70 40 100 70 130 100 160 130 190 160 11,2 24,6 8 22
S2 2.76 1.57 3.94 2.76 5.12 3.94 6.30 5.12 7.48 6.30 .44 .97 .32 .87
95 40 130 75 165 110 200 145 235 180 14 35,1 10 39
S3 3.74 1.57 5.12 2.95 6.50 4.33 7.87 5.71 9.25 7.09 .55 1.38 .39 1.18

Simplified Door Clutch

M295 L
min. max.
27 112
M295/A S0/S1 1.06 4.41
25 90
M295/B S0/S1 .98 3.54

V840E V840F/V840G

L
Size min. max.
30 55
S0 1.18 2.17
28 55
S1 1.10 2.17

V845 M600

L
Size A C H min. max.
48 7,2 52 30 55
S0 1.89 .28 2.05 1.18 2.17
64 8,1 58 28 55
S1 2.52 .32 2.28 1.10 2.17

L see L100 and M004D above.

28
mm
Optional Extras Dimensions inch

Auxiliary Contacts

M510B

E mounting VE mounting

Size M D Size M D
S1 16 64 S1 11,5 64
S2 18,7 84 S2 11,7 84
S3 17 128 S3 8 128

Control and Indicator Device (without Lamps)

S0 Q120/A1 - S0 Q120/A5 S0 Q120/A..A1 - S0 Q120/M..D5


Q120 Turn to operate Q120 Push-to-turn operation with a/c
C-, DH-switches C-, DH-switches
< back to table of contents >

S0 Q120/A00Z1 - S0 Q120/Z00Z5
Q120 Push-to-turn operation without a/c
C-, DH-, DK-switches
Lamp
With adaptor ring (LED recommended)

Face plate
Q100/A
51,8 x 51,8 mm

Q100B

Without interlock With interlock


M = 17,7 C = 5 M = 19,5 C = 6,5
.70 .20 .77 .26

Q100B *E

29
mm
Optional Extras Dimensions inch

Standard Door Clutch

M280D, M280D/.EF, M280E, M280E/.EF

For switches of size S0

For switches of size S1 and S0

< back to table of contents >


For switches of size S2 and S3
L = Shaft length

Size L L L L D1
36 55 56 75 76 95 96 116 19-22
S0 1.42 2.17 2.20 2.95 2.99 3.74 3.78 4.57 .75-.87
36 55 56 75 76 95 96 116 19-22
S0 1.42 2.17 2.20 2.95 2.99 3.74 3.78 4.57 .75-.87
32 57 58 77 78 97 98 118 19-22
S1 1.26 2.24 2.28 3.03 3.07 3.82 3.86 4.65 .75-.87
60 90 90 120 120 150 150 180 26-30
S2 2.36 3.54 3.54 4.72 4.72 5.91 5.91 7.09 1.02-1.18
60 95 95 130 130 165 165 200 26-30
S3 2.36 3.74 3.74 5.12 5.12 6.50 6.50 7.87 1.02-1.18

M700 M701

M800 M810

30
mm
Optional Extras Dimensions inch

Indicator Lamp Device

Q200/A1, Q200/A2, Q200/B1, Q200/B2


For switches of size S0 For switches of size S1

For switches of size S2 For switches of size S3


< back to table of contents >

Stop and Go Device

V160

Spring Return over several Positions

M470/A, M470

M470/A M470
Size M M
33,3 33,3
S0 1.31 1.31
1 40,3 29,2
S0 1.59 1.15
33,3 22,2
S11 1.31 .87
75
S2 2.95
1
shaft hole 18,5 mm/.73 inch

31
mm
Optional Extras Dimensions inch

Push-pull Interlock

V110A, V115A, V130A, V135A M = Additional length of the switch


E, EG
Mount- E1 EG 2 FT2 FH3
ing
V110A V115A V110A V115A V110A V115A V110A V115A
V130A V135A V130A V135A V130A V135A V130A V135A
w/o 17,5 33,5 24,5 40,5 24,0 40,0 31,0 47,0
M a/c .69 1.32 .96 1.59 .94 1.57 1.22 1.85
with 33,5 33,5 40,5 40,5 40,0 40,0 47,0 47,0
M a/c 1.32 1.32 1.59 1.59 1.57 1.57 1.85 1.85
1-2 1-2 1-2 1-2 1-6 1-6 1-6 1-6
S .04-.08 .04-.08 .04-.08 .04-.08 .04-.24 .04-.24 .04-.24 .04-.24
1
shaft hole 15-19 mm/.59-.75 inch
FT2, FH3 2
shaft hole 19-22 mm/.75-.87 inch

V110, V115, V130, V135 M = Additional length of the switch

No. of auxiliary contacts

< back to table of contents >


0-2 3+4 5+6 7+8
Size M M M M S
39,9 57,4 74,9 92,4 0-4
S11 1.57 2.26 2.95 3.64 0-.16 1
For switch type CA..B, CH..B, CG..B,
29,5 47 64,5 82 0-4
S1 1.16 1.85 2.54 3.23 0-.16 DH..B

V110, V120, V130 M1 = Additional length of the switch


M2 = Additional length of the auxiliary switch

No. of auxiliary contacts


0 1+2 3+4 5+6 7+8
Size M1 M1+M2 M1+M2 M1+M2 M1+M2 S
1 51,7 101,4 120,4 139,4 158,4 0-4,5
S1 2.04 3.99 4.74 5.49 6.24 0-.18
69 127,6 146,6 165,6 184,6 0-5,5
S2 2.72 5.02 5.77 6.52 7.27 0-.22
85 151,6 170,5 189,5 208,5 0-7 1
S3 3.35 5.96 6.71 7.46 8.21 0-.28 Only for V120

Interlock between Switches and Tandem Drive


V600/B, V600/C, M300/B, M300/C, M300/D

Size A B D E F G H M S
48 66 8,5 62 128 194 260 25 1,4-4,5
S1 1.89 2.60 .34 2.44 5.04 7.64 10.24 .98 .06-.18
68 93 11,2 92 183 276 369 30 1,5-7,0
S2 2.68 3.66 .44 3.62 7.20 10.87 14.53 1.18 .06-.28
88 144 14 130 274 418 562 24 1,5-8,3
S3 3.46 5.67 .55 5.13 10.79 16.47 22.13 .94 .06-.33

32
mm
Optional Extras Dimensions inch

Push Button Interlock

V400/A1, V400/A2, V400/B1, V400/B2

For switches of size S0 and S1

No. of auxiliary contacts


2 4
21,7 34,4
L .85 1.35

For switches of size S2


< back to table of contents >

For switches of size S3

Electromechanical Interlock

V140

For switches of size S1

M
S1 13
CA40-63, A11, A25 35,2

For switches of size S1, S2 and S3

M1 = Additional length for the interlock


M2 = Additional length for the coupling pieces of the solenoid
Additional length for the solenoid upon request.

Size M1 + M2 S
56 0-4
S1 2.20 0-.16
102 0-5,5
S2 4.02 0-.22
111,1 0-7
S3 4.37 0-.28

33
mm
Optional Extras Dimensions inch

Bayonet/Switch Coupling

M270
Coupled switch
Size S1 S2 S3
Main switch M M M
9,8
S1 .39
12,9
S2 .51
32,9
S3 1.30

M275
Coupled switch
Size S00 S0 S1 S2
Main switch M M M M
0 5,5
S0 0 .22
1,3 0,8
S1 .05 .03
10,2 4,4 2,9
S2 .40 .17 .11
12,7 12,2 11,4 11,4
S3 .50 .48 .45 .45

< back to table of contents >


Slip Clutch and Ratchet Coupling

M200, M230

M = One switch stage

Electromechanical Trip Device (Undervoltage Release and Shunt-trip)

V350/A, V350/B, V350/D


V360/A, V360/B, V360/D

34
mm
Optional Extras Dimensions inch

Special Drive Units

G800/A G800/B G800/C

G900/B
< back to table of contents >

Ground and Neutral Terminal

H040/E, H040/N, H040/NE

Motor Drive

R300

35
mm
Optional Extras Dimensions inch

Key-lock Device with small Cylinder Lock

V750

Switch type No. of Conduit entries 4 x


stages A B C E F ISO
64 50 68,8 36 26
CA10 2 2.52 1.97 2.71 1.42 1.02 20
82 68 75,5 52 29
CA11, CA20 1+2 3.23 2.68 2.97 2.05 1.14 20

For 1 stage CA10 switches with plaster depth trim

For base mounting with type of mounting VE21

Switch Type A L

< back to table of contents >


CA4, CG4 35,57 45
1.40 1.77
52,3 56,6
CA10, CA11, CA20, CA25, CG8, CH10, DH10
1.77"

2.06 1.73
45

Fl. CA4 CG4 CA10 CA11 CA20 CA25 CG8 CH10 DH10
S S Smin Smax Smin Smax Smin Smax Smin Smax Smin Smax Smin Smax Smin Smax
A S L 44 44 52 48 56 48 56 50 58 52 60 54 60 54 60
1 - 1.73 1.73 2.05 1.89 2.20 1.89 2.20 1.97 2.28 2.05 2.36 2.13 2.36 2.13 2.36
44 54 54 60 60 68 60 68 64 72 64 72 68 74 72 74
2 1.73 2.13 2.13 2.36 2.36 2.68 2.36 2.68 2.52 2.83 2.52 2.83 2.68 0.77 2.83 2.91
50 68 64 72 72 74 74 74
3 - - - - - - - -
1.97 2.68 2.52 2.83 2.83 2.91 2.91 2.91
58 72 74
4 - - - - - - - - - - - - -
2.28 2.83 2.91
68
5 - - - - - - - - - - - - - - -
2.68

max. 5,5 31,8 V750D/5 and V750D/2


.22" 1.27"

For single hole mounting combined with 16/22 mm

12,5
Front ring 29,5 mm Ø (mounting FS1)
.49"

Face plates
30 x 30 mm (mounting FS2)
30 x 39 mm (mounting FS4)

V750D/3

For single hole mounting 22 mm

Front ring 39 mm Ø (mounting FT1)

Face plate
48 x 48 mm (mounting FT2)
64 x 64 mm (mounting FH3)
48 x 59 mm (mounting FT6)
64 x 78,5 mm (mounting FH4)

36
mm
Optional Extras Dimensions inch

Key-lock Device with Kaba Lock

V750D

With front ring (mounting EL)

Locking program M
37,2
1A-1G 1.46
47,2
2G-2L 1.86

V750D/A, V750D/B
Face plates
48 x 48 mm (mounting E)
48 x 60 mm (mounting E)

Locking program S L
1-3,5 40,3
1A-1G .04-.14 1.59
1-12,5 49,3
2G-2L .04-.49 1.94
< back to table of contents >

V750D/A, V750D/B
Face plates
64 x 64 mm (mounting EG)
64 x 78,8 mm (mounting EG)

Locking program S L
1-3,5 39,8
1A-1G .04-.14 1.57
1-12,5 48,8
2G-2L .04-.49 1.92

V750D (mounting VE2)

Max. no. of stages CA10 CA11 CA20 CG8 CH10


50 mm
S= 1.97“
1 - - - -
61 mm 2 1 1 1 1
2.40“
67 mm - 2 2 - -
2.64“
69 mm 3 2 2 - -
2.72“

Key-lock Device with Profile Cylinder

V750E

37
mm
Optional Extras Dimensions inch

Key-lock Device with Kaba Lock

V750/A1

With face plate 64 x 64 mm (mounting EL2)


With front ring (mounting EL1)

Key-lock Device with Half-cylinder Lock

V755.UE1 V755.E Different drilling plans

< back to table of contents >


Safety Key-lock Device with separate Drive

V760/A.E, V760/B.E, V760/A, V760/B


Size of the
optional extra A B C E F G
48 36 82 12 40 24
S0 1.89 1.42 3.23 .47 1.57 .94
64 48 112 14,8 48 32
S1 2.52 1.89 4.41 .58 1.89 1.26
88 68 146 – 70 44
S2 3.46 2.68 5.75 – 2.76 1.73
130 104 181,5 – 86 65
S3 5.12 4.09 7.15 – 3.39 2.56

H D1 D2 D3 M S
31 8,5 22-23 5 9,5 1-4
S0 1.22 .33 .87-.91 .20 .37 .04-.16
34,5 10 34 5 20,2 1-4
S1 1.36 .39 1.34 .20 .80 .04-.16
35,5 12 34 5,4 15,5 1-5,5
S2 1.40 .47 1.34 .21 .61 .04-.22
36,5 15 34 7 24 1-7
S3 1.44 .59 1.34 .28 .94 .04-.28

V765 Different drilling plans V790

38
mm
Optional Extras Dimensions inch

Padlock Device

V840A
For 2 padlocks Size A B C
27,7 31,5 5
S0 1.07 1.24 .20
35 40 7
S1 1.38 1.57 .28

V840B

For 2 padlocks

V840D

For 2 padlocks

V840G, V840D
< back to table of contents >

For 3 padlocks A B C
64 40,1 9,2
V840G 2.52 1.58 .36
88 49,3 10
V840D 3.46 1.94 .39

V840G/B

For 3 padlocks

V840F/F

For 4 padlocks

V840F/B

For 4 padlocks

V840K

For 1 padlock

V845, V846 (S1 only)


Size A B C
48 51 7,2
S0 1.89 2.01 .28
64 58 8,1
S1 2.52 2.28 .32
88 73 9
S2 3.46 2.87 .35
130 86,5 9,2
S3 5.12 3.41 .36

39
mm
Optional Extras Dimensions inch

Padlock Device

V841
V842

V850

For 2 padlocks D

S1 V850/A1 10-15/.39-.59
S1 V850/11 8-15/.31-.59
S1 V850/12 10-15/.39-.59
S1 V850/13 19-22/.75-.87

For 3 padlocks D

S2 V850/A1 26-30/1.02-1.18
S2 V850/11 10-15/.39-.59
S2 V850/12 26-30/1.02-1.18

< back to table of contents >


S2 V850/13 26-30/1.02-1.18

For 6 padlocks D

S3 V850/A1 15.5-20/.61-.79
S3 V850/11 26-30/1.02-1.18
S3 V850/12 15.5-20/.61-.79
S3 V850/13 22-25/.87-.98

PFR (Power Failure Release)

Size S0

Without trip-free release M


23,3
.92
31,5
With trip-free release 1.24

Size S1

M
S1 10,2
CA40-63, A25 22,9

40
mm
Optional Extras Dimensions inch

Lockout-relays

With manual release

M
S0, S1 10,2
CA40-63, A25 22,9
< back to table of contents >

Without manual release

Rectangular Add-on Face Plates

PRA PRB F991/...-..., F991/.../C-...

PRA PRB
S00 S0 S1 S2 S3 S00 S0
29,5 47,8 63,8 87,8 129,8 29,5 47,8
A 1.16 1.88 2.51 3.46 5.11 1.16 1.88
35 48 60 80 115 35 48
B 1.38 1.89 2.36 3.15 4.53 1.38 1.89
4 4 5 6 7 4 4
C .16 .16 .20 .24 .28 .16 .16
0,7 0,7 0,8 1 1,2 0,7 0,7
M .03 .03 .03 .04 .05 .03 .03

PRC PRD
PRC PRD
S00 S0 S1 S00 S0
29,5 47,8 63,8 29,5 47,8
A 1.16 1.88 2.51 1.16 1.88
25,5 36 47 25,5 36
B .98 1.42 1.85 .98 1.42
4 4 5 4 4
C .16 .16 .20 .16 .16
0,7 0,7 0,8 0,7 0,7
M .03 .03 .03 .03 .03

41
mm
Enclosures Dimensions inch

Plastic Enclosures

Conduit entries
Mounting Switch type Max. no. of stages A B C 4 x D1 2 x D2 E

CA4 2 90 70 60 16 - 82
KS3 CG4 1 3.54 2.76 2.36 .63 3.23
CS3 CA4 3
CG4 2 90 70 77 16 - 82
CG6 2 3.54 2.76 3.03 .63 3.23

< back to table of contents >


CA10 4
CA11 3
KS10, KS11, KS12 CA20, CA25, CG8 2 121 86 80 20/25 20 110
CS10, CS11, CS12 CH10-CHR16 2 4.76 3.39 3.15 .79/.98 .79 4.33
KS50, KS51, KS52 CA10 6
CS50, CS51, CS52 CA11, CA20 5 121 86 106 20/25 20 110
CA25, CG8, CH10-CHR16 4 4.76 3.39 4.17 .79/.98 .79 4.33
KL10, KL11, KL12 CA10 3
KL50, KL51, KL52 CA11, CA20, CA25, CG8 2 160 85 80 20/25 20 150
CL50, CL51, CL52 CH10-CHR16 2 6.30 3.35 3.15 .79/.98 .79 5.91
CL10, CL11, CL12

42
mm
Enclosures Dimensions inch

Plastic Enclosures (Front Drive)

/ /
/

For switch type For switch type For switch type


CA10 CA11, CA20, CA10B, A11, A14, CA40, CA50,
CA11B, CA20B, CH10, CA63
CH16, CA25
< back to table of contents >

PN. PF.
Switch type No. of stages C C ISO
A11, A25 1-3 89 94,5 M25
4-6 132 137,5
1 36,6 41,3
CA10 2 45,8 50,8 M20
3 55,3 60,3
4 64,8 69,8
CA11, CA20, CA11B, 1+2 59,7 64,7 M20
CA20B
CA11, CA20, CA10B, CA11B, 3 + 41 85,1 90,1 M20
CA20B
1 59,7 64,7
CH10, CH16 2+3 85,1 90,1 M20
4 93 98
1+2 59,7 64,7
CA25 3 85,1 90,1 M20
4 93 98
CA40, CA50, CA63 1-3 89 94,5 M25
4-6 132 137,5

1
CA10B only for 4 stages
43
mm
Enclosures Dimensions inch

Plastic Enclosures (Lateral Drive)

Conduit entries
Switch type Max. no. of stages A B C E F G Z1 Z3 ISO
CA10, CA10R, CAD11, CAD12, CA10B 4 92 90 75 80 68 12
A11, CA11, CA20, CA11B, CA20B 3 3.62 3.54 2.95 3.15 2.68 .47 - M25

CA10, CA10R, CAD11, CAD12 7 115 90 75 80 91 12


CA10B 6 4.53 3.54 2.95 3.15 3.58 .47 - M25
A11, CA11, CA20, CA11B, CA20B 5

CA10, CA10R, CAD11, CAD12 10 140 90 75 80 116 12


CA10B 9 5.51 3.54 2.95 3.15 4.57 .47 - M25
A11, CA11, CA20, CA11B, CA20B 7

< back to table of contents >


CA10, CA10R, CAD11, CAD12, CA10B 12 165 90 75 80 141 12
A11, CA11, CA20, CA11B, CA20B 9 6.50 3.54 2.95 3.15 5.55 .47 - M25

A11, CA11, CA20, CA11B, CA20B 11 190 90 75 80 166 12


7.48 3.54 2.95 3.15 6.54 .47 - M25

A11, CA11, CA20, CA11B, CA20B 12 215 90 75 80 191 12


8.46 3.54 2.95 3.15 7.52 .47 - M25

Aluminum Enclosures

Conduit entries
Switch types No. of stages A B C D E F F1 Z1 Z2 ISO
CA10, CA10R 3 80 75 57 4,8 63 - 52
CA11, CA20 2 3.15 2.95 2.24 .19 2.48 2.05 - M20

CA10B 4 100 100 80 4.8 86 66 -


CA11B, CA20B 3 3.94 3.94 3.15 .19 3.39 2.60 - M20
CA25B 2

A11, A14 5
CA10B 7 140 140 90 7 120 93 -
CA11B 6 5.51 5.51 3.54 .28 4.72 3.66 - M25
CA20B, CA25B 5
CA40, CA50, CA63 5

A11, A14 10
CA10B 12 200 140 90 7 93 180 -
CA11B, CA20B 10 7.87 5.51 3.54 .28 3.66 7.09 - M25
CA25B 9
CA40, CA50, CA63 10

44
Notes:

45
The Range of “Blue Line” Switchgear
Technical literature covering the following products is available on request.

Catalog
Number

Main Switches and Main Switches with Emergency Function 16 A-315 A


Maintenance Switches 20 A-315 A
Switch Disconnectors 20 A-315 A 500
According to IEC 60947-3, EN 60947-3, VDE 0660 part 107, IEC 60204, EN 60204 and VDE 0113

C, CA and CAD Switches 10 A-315 A and L Switches 350 A-2400 A


C, CA and CAD switches are designed for universal application. They are recommended for instrument, isolator,
double-throw and motor control.
L switches are designed for load and off-load applications. They are used to switch resistive or low inductive 100
loads.

Optional Extras and Enclosures


The complete product line, a large number of optional extras is available, including door interlocks, push-pull
devices, cylinder and padlock attachments, control and indicator devices, AC motor drives, as well as 101
enclosures, both insulated and metal.

A and AD Switches 6 A-25 A


A and AD switches have 4 contacts in each switching stage. These switches provide an extensive range of switch
functions and require a minimum mounting depth. Up to 24 switching positions are possible, with availability of 110
48 contacts per 12 stage switch column.

CG, CH and CHR Switches 10 A-25 A


Ultra compact CG, CH and CHR switches are ideally suited for control and instrumentation applications.
Switch terminals are “finger-proof” and conveniently accessible for wiring and are delivered open. All CG4 swit-
ches offer specially designed gold plated contacts or H-bridges with “cross-wire” contact systems, which facilita-
120
tes their use in electronic circuitry and chemically aggressive environments.

DH, DHR, DK and DKR Switches 6 A-16 A


DH, DHR, DK and DKR switches incorporate unique corrosion resistant contacts that permit operation on system
voltage as low as 1 V. They have fully enclosed and protected contacts which can be operated either by rotary
and/or lateral handle movement. D switches are used in calibration and semiconductor circuits. They are also
130
used for relay and contactor control.

X Switches 200 A-630 A


X switches can be applied for load, tap and gang switching duties. They incorporate 6 contacts in each switching
stage. Their compact design provides a minimum length dimension for mounting purposes.
140
KG Switches 20 A-315 A and KH and KHR Switches 16 A-80 A
KG, KH and KHR switches are excellent circuit interruptors. They have high through fault and fault making
capacities and are especially designed for use as isolators and safety switches for machine tools, distribution
panels and switchboards. KG ON/OFF switches offer unusually high dimensioned air and creepage distances 150
between terminals which are designed for time saving “straight-line” wiring. ON/OFF switches are available with
up to 8 poles and double-throw switches are available with up to 4 poles.

Push Buttons and Pilot Lights, 22,5 mm Ø


A complete range of state-of-the-art push buttons and pilot lights represent an ideal combination of functional
security and economical efficiency in a modular design.
302

We reserve the right to make technical and dimensional changes without prior notice.
46
SALES AND SERVICE ORGANIZATION

Australia Great Britain Poland


Kraus & Naimer Pty. Ltd. Kraus & Naimer Ltd. ASTAT LOGISTYKA SP. Z O.O.
379 Liverpool Road, ASHFIELD, N.S.W. 2131 115 London Road Dąbrowskiego 441
P: 1800 567 948 NEWBURY/BERKSHIRE RG14 2AH 60451 POZNAŃ
E: sales-au@krausnaimer.com P: +44 1635 262626 P: +48 61 849 80 89
F: +44 1635 37807 E: k.swiderski@astat.pl
E: sales-uk@krausnaimer.com
Austria
Kraus & Naimer GmbH Portugal
Schumanngasse 39 Greece ELECTRICOL-DAMAS, FERREIRA & DAMASCENO, LDA.
1180 WIEN KALAMARAKIS-SAPOUNAS S. A. Apartado 1063, S. Ant. Cavaleiros
P: +43 1 404 06 0 Ionias & Neromilou Str., P. O. Box 46566 2670 LOURES
E: sales-at@krausnaimer.com 13671 ACHARNES/ATHENS P: +351 21 989 8939
P: +30 2 10 240 6000 6 F: +351 21 988 6464
F: +30 2 10 240 6007 E: electricol@electricol.pt
Belgium, Luxembourg E: kalamarakis.sapounas@ksa.gr
Kraus & Naimer B.V.
Ikaros Business Park Singapore, India, Middle East – UAE
Ikaroslaan 2 Hungary Kraus & Naimer Pte. Ltd.
1930 ZAVENTHEM GANZ KK KFT. 115A, Commonwealth Drive
P: +32 2 757 0141 X. Kõbányal út 41/c, Postfach 87 #03-17/23
F: +32 2 757 1640 1475 BUDAPEST SINGAPORE 149 596
E: sales-be@krausnaimer.com P: +36 1 261 5479 P: +65 6473 8166
E: ganzkk@ganzkk.hu E: sales-sg@krausnaimer.com

Brazil
Central and South America Iceland Slovenia
Kraus & Naimer Ind. Com. Ltda. JOHAN RÖNNING LTD. SCHRACK TECHNIK D.O.O.
Rua Santa Monica, 1061 Klettagarðar 25 Pameče 175
Parque Industrial San Jose 104 REYKJAVIK SI-2380 SLOVENJ GRADEC
P: +55 11 2198 1288 P: +354 5200 800 P: +386 2 88 392 00
F: +55 11 2198 1251 E: ronning@ronning.is F: +386 2 88 434 71
E: knbrasil@krausnaimer.com.br E: d.goljat@schrack.si

Republic of Ireland
Canada Kraus & Naimer Ltd. Republic of South Africa
Kraus & Naimer Ltd. 4235 Atlantic Avenue Kraus & Naimer Pty. Ltd.
219 Connie Crescent, Unit 13A Westpark Business Campus 7 Village Crescent, Linbro Village
CONCORD, Ontario, L4K 1L4 Shannon, Co. Clare Linbro Business Park, SANDTON 2065
P: +1 905 738 1666 P: +353 61 704700 P. O. Box 511, KELVIN 2054
E: sales-ca@krausnaimer.com F: +353 61 471084 P: +27 11 608 6060
E: sales-ie@krausnaimer.com E: sales-za@krausnaimer.com

Cyprus
ELECTROMATIC CONSTRUCTIONS LTD. Italy Spain
72, Evagoras Pallikarides Str., 2235 LATSIA-Nicosia Kraus & Naimer s.r.l. Kraus & Naimer B.V.
P. O. Box 12630, 2251 LATSIA-Nicosia Via Terracini, 9 P: +34 662 696 014
P: +357 2 48 41 41 24047 TREVIGLIO (BG) E: sales-es@krausnaimer.com
F: +357 2 48 57 47 P: +39 0363 30 11 12
E: electromatic@cytanet.com.cy E: sales-it@krausnaimer.com
Sweden
Kraus & Naimer AB
Czech Republic Japan Dr. Widerströms Gata 11, Hägersten
OBZOR, výrobní družstvo Zlín Kraus & Naimer Ltd. Box 42097, 126 14 STOCKHOLM
Na Slanici 378 Yoshiwada Building 2F P: +46 8 97 00 80
763 02 ZLÍN 1-11-6 Hamamatsucho E: sales-se@krausnaimer.com
P: +420 577 195 150 Minato-Ku, TOKYO 105-0013
F: +420 577 195 152 P: +81 3 3436 6151
E: odbyt@obzor.cz F: +81 3 3436 6325 Switzerland
E: sales-jp@krausnaimer.com AWAG Elektrotechnik AG
Sandbüelstraße 2
Denmark CH-8604 VOLKETSWIL
THIIM A/S Mexico P: +41 44 908 19 19
Transformervej 31 JC INGENIERÍA Y CONTROL, SA DE CV. E: info@awag.ch
2860 SOEBORG Ángel Gaviño 30.
P: +45 4485 8000 C. Satélite, C. Medicos,
F: +45 4485 8005 Naucalpan Edo. de Mexico, C.P. 53100 Turkey
E: thiim@thiim.com P: +52 55 55 62 75 77 KARDES ELEKTRIK SANAYI VE TICARET A.S.
F: +52 55 55 62 04 34 Yassioren Mah. Hifa Sok. No: 4
E: ventas@jcingenieriaycontrol.com 34277 Arnavutkoy-Istanbul-Turkey
Finland P: +90 212 624 92 04 118
Kraus & Naimer Oy F: +90 212 592 48 10
Kiitoradankuja 8 Netherlands E: info@unalkardes.com.tr
01530 VANTAA Kraus & Naimer B.V.
P: +358 9 825 424 0 Wegtersweg 38-40, Postbus 199
E: sales-fi@krausnaimer.com 7556 BR HENGELO (Ov.) USA
P: +31 74 291 9441 Kraus & Naimer Inc.
F: +31 74 291 98380 760 New Brunswick Road
France E: sales-nl@krausnaimer.com SOMERSET, NJ 08873
Kraus & Naimer s.a.s. P: +1 732 560 1240
33, rue Bobillot E: sales-us@krausnaimer.com
75013 PARIS New Zealand
P: +33 1 58 40 80 80 Kraus & Naimer Ltd.
E: sales-fr@krausnaimer.com 42 Miramar Avenue, WELLINGTON 6022
P. O. Box 15-009, WELLINGTON 6243
P: + 64 0800 736 522
Germany E: sales-nz@krausnaimer.com
Kraus & Naimer GmbH
Wikingerstraße 20-28, 76189 KARLSRUHE
Postfach 10 01 24, 76231 KARLSRUHE Norway
P: +49 721 59 88 0 Kraus & Naimer AB Avd. Norge
E: sales-de@krausnaimer.com Postboks 27 Vollebekk
0516 Oslo
P: +47 22 64 44 20
E: sales-no@krausnaimer.com
Contact us:
www.krausnaimer.com

You might also like