Microwave Oven Installation Guide
Microwave Oven Installation Guide
CMOH30SS
INSTALLATION GUIDE
US CA
CONTENTS
Mounting space 4
Wall construction 4
Installation hardware 6
Ventilation system 7
Oven installation 9
Mounting deflector 11
3 EN
MOUNTING SPACE WALL CONSTRUCTION
Please read all instructions thoroughly before installing the Over the Range Convection This Over the Range Microwave Oven should be mounted against and supported by a flat
Microwave Oven. Two people are recommended to install this product. vertical wall. The wall must be flat for proper installation. If the wall is not flat, use spacers to
fill in the gaps. Wall construction should be a minimum of 2" x 4" wood studding and 3/8"
If a new electrical outlet is required, its installation should be completed by a qualified
or more thick dry wall or plaster/lath. The mounting surfaces must be capable of supporting
electrician before the microwave oven is installed. See ELECTRICAL GROUNDING
weight of 110 pounds—the oven and contents—AND the weight of all items which would
INSTRUCTIONS page 5.
normally be stored in the top cabinet above the unit.
This microwave oven requires a mounting space on a wall as shown in Figure 1.
The unit should be attached to a minimum of one 2" x 4" wall stud.
For proper installation and servicing, a 2-inch space is necessary between the top of the range
To find the location of the studs, one of the following methods may be used:
backsplash and the bottom of the Over the Range Microwave Oven.
A. Use a stud finder, a magnetic device which locates the nails in the stud.
B. Use a hammer to tap lightly across the mounting surface to find a solid sound. This will
indicate stud location.
12" The center of the stud can be located by probing the wall with a small nail to find the edges of
30" the stud and then placing a mark halfway between the edges. The center of any adjacent studs
15.5" will normally be 16" or 24" to either side of this mark.
Note: In the event that the unit will be unable to be supported by any stud, it will be necessary
to use special care in the placement of the toggle bolts and top cabinet screws. See Wall
Minimum 2" 30" or more
Backsplash from cooking Template for details. The top cabinet should be tested to ensure it is securely attached to the
surface wall. Place extra weight up to 110 pounds inside the top cabinet to test the support.
16" or 24"
2"x 4"
Wood Studs
66" or more
from floor
Figure 1
Figure 2
4 EN
ELECTRICAL GROUNDING INSTRUCTIONS HOOD EXHAUST DUCT
This appliance must be grounded. This microwave oven is When the hood is vented to the outside, a hood exhaust duct is required. All ductwork must
equipped with a cord having a grounding wire with a grounding be metal; absolutely do not use plastic duct. Check that all connections are made securely.
plug. It must be plugged into a wall receptacle that is properly Please read the following carefully:
installed and grounded in accordance with the National
Electrical Code and local codes and ordinances. In the event Exhaust connection
of an electrical short circuit, grounding reduces risk of electric
The hood exhaust has been designed to connect to a standard 3 1⁄4" x 10" rectangular duct. If
shock by providing an escape wire for the electric current.
round duct is required, a rectangular-to-round adapter must be used.
WARNING - IMPROPER USE OF THE GROUNDING PLUG CAN RESULT
IN A RISK OF ELECTRIC SHOCK. DO NOT USE AN EXTENSION CORD. Rear exhaust
IF THE POWER SUPPLY CORD IS TOO SHORT, HAVE A QUALIFIED If a rear or horizontal exhaust is to be used, care should be taken to align the exhaust with the
ELECTRICIAN OR SERVICEPERSON INSTALL AN OUTLET NEAR THE space between the studs, or wall should be prepared at the time it is constructed by leaving
APPLIANCE. enough space between wall studs to accommodate exhaust.
The microwave oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY
CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN FROM THE PLUG.
Maximum duct length
For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter
The Power Supply Cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15
round duct should not exceed 140 feet.
Amp, or more branch circuit, single grounded receptacle. The receptacle should be located
inside the cabinet directly above the Microwave Oven mounting location. Elbows, adapters, wall, roof caps, etc. present additional resistance to air flow and are
equivalent to a section of straight duct which is longer than their actual physical size. When
Notes:
calculating the total length, add the equivalent lengths of all transitions and adapters plus
1. If you have any questions about the grounding or electrical instructions, consult a qualified the length of all straight duct sections. Figure 4 shows the approximate feet of equivalent
electrician or serviceperson. length of some typical ductwork parts. Use the values in parentheses for calculating air flow
2. Neither Fisher & Paykel nor the dealer can accept any liability for damage to the oven resistance equivalent, which should total less than 140 feet.
or personal injury resulting from failure to observe the correct electrical connection
procedures.
Ground
Receptacle 90˚ Elbow 45˚ Elbow Adaptor 10˚ Wide elbow
(10 ft. / 304.8 cm.) (5 ft. / 152.4 cm.) (5 ft. / 152.4 cm.) (10 ft. / 304.8 cm.)
Opening for
Power Cord
Figure 4
5 EN
TOOLS RECOMMENDED FOR INSTALLATION INSTALLATION HARDWARE
z Phillips screwdriver The INSTALLATION HARDWARE (items 1-8) packed with the oven should contain the
z Electric drill following:
z Scissors
ITEM NAME QUANTITY PART CODE
z Pencil
z Tape 1 Wood Screw 5 x 30 mm 6 290109
z Measure tape Toggle Bolt #10 - 24 x 50 mm 290106
2 4
z 1 1⁄2" wood bit or metal hole cutter (if metal cabinet is used)
z 1⁄2", 5⁄8" and 3⁄32" drill bits 3 Top Cabinet Screw 5 x 60 mm 2 290108
z Saw to cut exhaust opening (if needed) Flat Washer 30 mm diameter 290107
4 2
z Protective drop cloth for product and range—you may also use carton for protection
5 Grommet 1 290105
1 2 3 4 5
6 7 8
Figure 5
6 EN
PREPARATION OF THE OVEN VENTILATION SYSTEM
1. Open the bottom of the carton, remove oven and all packing materials. This Over-the-range microwave oven is designed for adaptation to three types of hood
2. CHECK THE OVEN. ventilation systems. Select the type required for your installation.
Check the oven for any damage, such as misaligned or bent door, damaged door seals and A. RECIRCULATING - NON-VENTED, DUCTLESS OPERATION
sealing surfaces, broken or loose door hinges and latches and dents inside the cavity or
on the door. If there is any damage, do not operate the oven and contact your dealer or The unit is shipped assembled for recirculating.
Fisher & Paykel AUTHORIZED SERVICER.
Note:
3. Rest the microwave oven on its side as shown in Figure 6.
1. The Exhaust Damper Assembly (Figure 11) is not required for recirculating operation.
4. Remove the two screws which secure the mounting plate to the rear side of the oven.
2. The Charcoal Filter provided with the unit must be installed behind the exhaust louver
Remove the mounting plate. The two screws can be discarded.
before use. For instructions on installation of the filter, refer to the "Cleaning and Care"
Note: If the unit you purchased does not have the mounting plate attached to the rear side of section in the Use and Care Guide.
the oven, please disregard this section and continue to Section 8. 3. The Charcoal Filter should be replaced every 6 to 12 months, depending on use.
Step
1
z Remove and save the 4 screws from
Fan Cover Bracket. Remove Fan Cover
Bracket by sliding it in the opposite
direction of the arrow on the Fan Cover
Bracket, as shown in Figure 7.
Figure 7
Mounting plate
Step
Grease filter openings z Lift Hood Fan Unit carefully and slip
Figure 6
2 wires out of cavity. See Figure 8.
CAUTION:
Figure 8
7 EN
VENTILATION SYSTEM
Figure 9 Figure 12
Step
Put the wire back into the cavity. Step
4 2 z Lift the Hood Fan Unit carefully and slip
Step wires out of cavity. See Figure 13.
5 z Replace the fan cover bracket. Make sure
CAUTION:
the fan blades are visible through the
rear openings in oven before proceeding. DO NOT PULL OR STRETCH BLOWER WIRING
Attach the fan cover bracket to the
unit with the 4 screws removed in step
Figure 13
1 above. See Figure 10. The hood fan
is now rotated for horizontal exhaust
Step Rotate the Hood Fan Unit 180˚ so that
operation. z
8 EN
VENTILATION SYSTEM OVEN INSTALLATION
This oven cannot be properly installed without referring to the mounting instructions found on
Step both templates.
5 Read and follow mounting information on both TOP CABINET TEMPLATE and WALL TEMPLATE.
z Attach the Fan Cover Bracket to unit
with the 4 screws removed in step 1
MOUNTING PLATE
above. See Figure 15. The Hood Fan
Unit is now rotated for vertical exhaust Step
operation. z Separate 4 Toggle Bolts 2, packed in the INSTALLATION HARDWARE, from the
1 Toggle Nuts.
Wire Box
Step
4 z Align the Mounting Plate carefully and
hold in position while tightening Toggle
Bolts. Pull Toggle Bolt toward you and
turn clockwise to tighten. Figure 19.
Figure 19
9 EN
MOUNTING OVEN TO THE WALL
Two people are recommended to attach the Over the Range Microwave Oven to the Mounting
Plate. Step
4
Step
Thread the power supply cord through the hole made in the bottom of the top
1 cabinet.
3 Figure 23
Step
z Tighten the two unit mounting
Make a bundle of the power supply cord and place it inside the cabinet.
screws located in the grease 6
filter openings. See Figure 21.
Figure 21
10 EN
MOUNTING DEFLECTOR CHECKLIST FOR INSTALLATION
1. Make sure the unit has been installed according to all of the Installation Instructions and
the Wall and Top Cabinet Templates.
2. Plug in the power cord.
3. Keep the use and care guide.
Deflector
11 EN
FISHERPAYKEL.COM
The models shown in this guide may not be available in all markets
and are subject to change at any time.
The product specifications in this guide apply to the specific products and
models described at the date of issue. Under our policy of continuous product
improvement, these specifications may change at any time.
For current details about model and specification availability in your country,
please go t
TINSEB515MRR7