c220m6 SFF Specsheet
c220m6 SFF Specsheet
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Detailed Chassis Front View . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Detailed Chassis Rear Views . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
One Half-Height Riser . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Three Half-Height Risers .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Two Full-Height Risers . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . 12
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
STEP 2 SELECT RISERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
STEP 3 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
STEP 4 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Memory Configurations, Features, and Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
STEP 5 SELECT DRIVE CONTROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
AHCI with SATA Interposer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cisco 12G SAS RAID Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cisco 12G SAS HBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
RAID Volumes and Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
STEP 6 SELECT DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Intel® Virtual RAID on CPU (Intel® VROC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
STEP 7 SELECT OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES . . . . . . . . . . . . . . . . . . 42
STEP 8 ORDER GPU CARDS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
STEP 9 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
STEP 10 SELECT INPUT POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
STEP 11 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . 49
STEP 12 SELECT MANAGEMENT CONFIGURATION (OPTIONAL) . . . . . . . . . . . . . . . . . . . . 50
STEP 13 SELECT SERVER BOOT MODE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
STEP 14 ORDER SECURITY DEVICES (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
STEP 15 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . 53
STEP 16 ORDER M.2 SATA SSDs (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
STEP 17 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 56
STEP 18 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Risers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Serial Port Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
KVM Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Memory Support for 3rd Generation Intel® Xeon® Scalable Processors (Ice Lake) . . . . . . . . 71
PMem Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
App Direct Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Memory Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
UPGRADING or REPLACING CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
UPGRADING or REPLACING MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
DISCONTINUED EOL PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
1 Cisco UCS C240 M6 Rack Server (Small Factor Disk Drive Model)
CONTENTS
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Extended Operating Temperature Hardware Configuration Limits . . . . . . . . . . . . . . . . . . . 98
Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Cisco UCS C240 M6 Rack Server (Small Form Factor Disk Drive Model) 2
CONTENTS
3 Cisco UCS C240 M6 Rack Server (Small Factor Disk Drive Model)
OVERVIEW
OVERVIEW
The UCS C220 M6 SFF server extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U
form factor with the addition of the 3rd Gen Intel® Xeon® Scalable Processors (Ice Lake), 16 DIMM slots per
CPU for 3200-MHz DDR4 DIMMs with DIMM capacity points up to 128 GB. The maximum memory capacity for
2 CPUs is listed here:
Front Drives
The UCS C220 M6 server has two LOM ports (10Gbase-T LOM) and a single 1 GbE management port. A
modular LAN on motherboard (mLOM) module provides up to two 100 GbE ports. A connector on the front of
the chassis provides KVM functionality.
The Cisco UCS C220 M6 server can be used standalone, or as part of the Cisco Unified Computing System,
which unifies computing, networking, management, virtualization, and storage access into a single
integrated architecture, enabling end-to-end server visibility, management, and control in both bare metal
and virtualized environments.
NOTE: All options listed in the Spec Sheet are compatible with Intersight Managed Mode, UCSM Managed
Mode, and Standalone configurations. To see the most recent list of components that are supported in
Intersight Managed Mode, see Supported Systems.
See Figure 1 on page 5 for front and rear views of the UCS C220 M6 server.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 4
OVERVIEW
Front View
5 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
DETAILED VIEWS
Detailed Chassis Front View
Figure 2 shows the detailed front view of the Cisco UCS C220 M6 SFF Rack Server.
14 Unit Identification button/LED 20 KVM connector (used with KVM cable that
provides two USB 2.0, one VGA, and one
serial connector)
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 6
DETAILED VIEWS
Notes:
1. You can mix and match in drive bays 1 - 4. For example, slots 1 and 2 can hold NVMe drives and slots 3 and 4
can hold SAS/SATA HDDs or SSDs.
2. If NVMe drives are selected, you must also select 2 CPUs.
3. If using a SATA Interposer board, up to a maximum of 8 SATA-only drives can be configured (slots 1-4 and 6-9
only)
7 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
Figure 4 shows the details of the rear panel for the UCS C220 M6 with three rear half-height PCIe risers.
Figure 5 shows the details of the rear panel for the UCS C220 M6 with two rear full-height PCIe risers.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 8
DETAILED VIEWS
NOTE: By default, servers come with only one half-height riser 1 installed. 2-CPU
servers support all three half-height risers.
Figure 3 Chassis Rear View (one half-height, 3/4 length PCIe riser)
9 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
Figure 4 Chassis Rear View (three half-height, 3/4 length PCIe risers)
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 10
DETAILED VIEWS
NOTE: 1-CPU servers support only full-height riser 1 while 2-CPU servers support
both full-height risers.
3 Power supplies (two, redundant as 1+1) 8 1 GbE dedicated Ethernet management port
4 Modular LAN on motherboard (mLOM) 9 -10 Dual 1/10 GbE Ethernet ports
(LAN1, LAN2)
LAN1 is left connector,
LAN2 is right connector
11 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature Description
Chassis One rack unit (1RU) chassis
CPU One or two 3rd Gen Intel® Xeon® Scalable Processors (Ice Lake)1
Chipset Intel® C621A series chipset
Memory 32 slots for registered DIMMs (RDIMMs) or load-reduced DIMMs (LR DIMMs) and
support for Intel® Optane™ Persistent Memory Modules (PMem)
Multi-bit Error This server supports multi-bit error protection.
Protection
Video The Cisco Integrated Management Controller (CIMC) provides video using the
Matrox G200e video/graphics controller:
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 12
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature Description
Expansion slots Three half-height riser slots
13 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature Description
Internal storage devices Drive storage:
Drives are installed into front-panel drive bays, which provide
hot-swappable access for SAS/SATA or NVMe drives. The server is orderable
in two different versions:
■ UCSC-C220-M6S (option 1):
• Up to 10 SFF SAS/SATA hard drives (HDDs) or SAS/SATA solid state
drives (SSDs).
• Optionally, up to four SFF NVMe PCIe SSDs. These drives must be
placed in front drive bays 1, 2, 3, and 4 only, can be mixed with
SAS/SATA drives, and are controlled from CPU 2. The rest of the bays
(5 - 10) can be populated with SAS/SATA SSDs or HDDs. Two CPUs are
required when choosing NVMe SSDs.
• If using a SATA Interposer, up to 8 SATA-only drives can be installed
(slots 1-4 and 6-9 only).
■ UCSC-C220-M6N (option 2):
• Up to 10 SFF NVMe PCIe SSDs only. The drives in slots 1, 2, 3, 4, 6,
and 7 are connected to CPU 2 and the drives in slots 5, 8, 9, and 10
are connected to CPU1. One or two CPUs are required when choosing
NVMe SSDs.
Other storage:
■ A mini-storage module connector on the motherboard supports a
boot-optimized RAID controller carrier that holds up to two SATA M.2
SSDs. Mixing different capacity SATA M.2 SSDs is not supported.
UCS-M2-HWRAID is required when selecting the M.2 SATA drives.
■ 8GB FlexMMC utility storage for staging of firmware and other user
data. 8GB FlexMMC storage is built into the motherboard on M6.
Integrated management Baseboard Management Controller (BMC) running Cisco Integrated
processor Management Controller (CIMC) firmware.
Depending on your CIMC settings, the CIMC can be accessed through the 1GE
dedicated management port, the 1GE/10GE OCP/mLOM ports, or a Cisco
virtual interface card (VIC).
CIMC manages certain components within the server, such as the Cisco 12G
SAS HBA.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 14
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature Description
Storage controllers The SATA Interposer board, 12G RAID HBA, or 12G SAS HBA. Only one of these
at a time can be used.
■ SATA Interposer board
• AHCI support of up to eight SATA-only drives (slots 1-8)
■ Cisco 12G RAID controller
• RAID support (RAID 0, 1, 5, 6, 10) and RAID0
• Supports up to 10 internal SAS/SATA drives
■ Cisco 12G SAS HBA
• No RAID support
• JBOD/Pass-through Mode support
• Supports up to 10 SAS/SATA internal drives
Modular LAN on The dedicated mLOM slot on the motherboard can flexibly accommodate the
Motherboard (mLOM) following cards:
slot
■ Cisco Virtual Interface Cards
UCSM UCS Manager (UCSM) 4.2(1) or later runs in the Fabric Interconnect and
automatically discovers and provisions some of the server components.
CIMC Cisco Integrated Management Controller 4.2(1) or later
Notes:
1. If NVMe drives are selected, you must also select 2 CPUs.
2. There are three PCIe riser connectors on the motherboard: they are labeled Riser 1, Riser 2, and Riser 3. If the
server is configured with three half-height risers, Riser 1 plugs into Riser 1 connector, Riser 2 plugs into Riser 2
connector, and Riser 3 plugs into Riser 3 connector. If the server is configured with two full-height connectors,
Riser 1 plugs into Riser 1 connector and Riser 2 plugs into Riser 3 connector. See Risers, page 65 for more
details.
15 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 16
CONFIGURING the SERVER
The Cisco UCS C220 M6 SFF servers do not include power supplies, CPUs, DIMM memory, Intel®
Optane™ Persistent Memory (PMem), hard disk drives (HDDs), solid-state drives (SSDs), NVMe
drives, riser 1, riser 2, riser 3, tool-less rail kit, or option cards.
NOTE: Use the steps on the following pages to configure the server with
the components that you want to include.
17 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
■ The System defaults to automatically include the one half-height riser shown in the Table 3.
(factory installed)
■ If you select 1 CPU configuration, the system includes two half-height risers (riser 1 and riser
2) and a blank panel for the riser 3
■ If you select 2 CPU configuration, the system includes all the three half-height risers (riser 1
and riser 2, 3).
■ If you order PID UCSC-GPURKIT-C220, the system includes two full-height risers (riser 1 and
riser 2)
Approved Configurations
(1) Half-height riser 1 only (controlled from CPU1). This is the default and is automatically
included.
(2) Half-height risers 1 and 2 only. Risers 1 and 2 are controlled from CPU1
(3) Half-height risers 1, 2, and 3 only. Risers 1 and 2 are controlled from CPU1 and Riser 3 is
controlled from CPU2
(4) Full-height risers 1 and 2 only. Riser 1 is controlled from CPU1 and riser 2 is controlled from
CPU2.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 18
CONFIGURING the SERVER
Select CPUs
The available CPUs are listed in Table 4. See Table 5 on page 21 for CPU suffix notations.
Highest DDR4
Clock
Cache UPI1 Links DIMM Clock PMem
Product ID (PID) Freq Power (W) Cores
Size (MB) (GT/s) Support (MHz)2 Support
(GHz)
19 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Highest DDR4
Clock
Cache UPI1 Links DIMM Clock PMem
Product ID (PID) Freq Power (W) Cores
Size (MB) (GT/s) Support (MHz)2 Support
(GHz)
Notes:
1. UPI = Ultra Path Interconnect.
2. If higher or lower speed DIMMs are selected than what is shown in Table 6 on page 24 for a given CPU speed,
the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.
3. The maximum number of UCS-CPU-I8351N CPUs is one
4. The maximum number of UCS-CPU-I6314U CPUs is one
5. The maximum number of UCS-CPU-I6312U CPUs is one
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 20
CONFIGURING the SERVER
S Max SGX enclave Supports Max SGX enclave size (512GB) to enhance and
size protect the most sensitive portions of a workload or
service
M Media and AI Media, AI and HPC Segment Optimized for lower TDP &
optimized higher frequencies delivering better perf/w
Y Speed Select – Intel® Speed Select Technology provides the ability to set
Performance Profile a guaranteed base frequency for a specific number of
cores, and assign this performance profile to a specific
application/workload to guarantee performance
requirements. It also provides the ability to configure
settings during runtime and provide additional frequency
profile configuration opportunities.
CAUTION: For systems configured with 3rd Gen Intel® Xeon® Scalable
Processors (Ice Lake) processors operating above 28o C [82.4o F], a fan fault or
executing workloads with extensive use of heavy instructions sets such as Intel®
Advanced Vector Extensions 512 (Intel® AVX-512), may assert thermal and/or
performance faults with an associated event recorded in the System Event Log
(SEL).
21 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Approved Configurations
■ For 1-CPU systems, the server is shipped by default with riser 1 only
■ For 2-CPU systems, the server is shipped:
— With half-height risers 1, 2, and 3 by default, or
— With full-height risers 1 and 2 if you order a non-T4 GPU with more than 75 W power
dissipation
NOTE:
■ You cannot have two I8351N or two I6314U or I6312U CPUs in a two-CPU
configuration.
■ If you configure a server with one I8351N CPU or one I6314U CPU or one
I6312U CPU you cannot later upgrade to a 2-CPU system with two of these
CPUs.
■ With using single CPU, up to four NVMe drives are allowed.
Caveats
■ The selection of 1 or 2 CPUs depends on the desired server functionality. See the following
sections:
— STEP 4 SELECT MEMORY, page 23
— STEP 5 SELECT DRIVE CONTROLLERS, page 30
— STEP 6 SELECT DRIVES, page 34
— STEP 7 SELECT OPTION CARD(s), page 39
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 22
CONFIGURING the SERVER
Memory is organized with eight memory channels per CPU, with up to two DIMMs per channel, as
shown in Figure 6.
Slot 2
Slot 2
Slot 1
A1 A2 A2 A1
Chan A Chan A
B1 B2 B2 B1
Chan B
Chan B
C1 C2 C2 C1
Chan C Chan C
D1 D2 D2 D1
Chan D Chan D
CPU 1 CPU 2
E1 E2 E2 E1
Chan E Chan E
F1 F2 F2 F1
Chan F Chan F
G1 G2 G2 G1
Chan G Chan G
H1 H2 H2 H1
Chan H Chan H
23 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Select the memory configuration and whether or not you want the memory mirroring option.
The supported memory DIMMs, DCPMMs, DCPMM Memory Mode, and the mirroring option are
listed in Table 6.
Ranks
Product ID (PID) PID Description Voltage
/DIMM
3200-MHz DIMMs
UCS-MR-X16G1RW 16 GB RDIMM SRx4 3200 (8Gb) 1.2 V 1
UCS-MR-X32G1RW 32 GB RDIMM SRx4 3200 (16Gb) 1.2 V 1
UCS-MR-X32G2RW 32 GB RDIMM DRx4 3200 (8Gb) 1.2 V 2
UCS-MR-X64G2RW 64 GB RDIMM DRx4 3200 (16Gb) 1.2 V 2
UCS-ML-128G4RW 128 GB LRDIMM QRx4 3200 (16Gb) (non-3DS) 1.2 V 4
Intel® Optane™ Persistent Memory (PMem)1
UCS-MP-128GS-B0 Intel® Optane™ Persistent Memory, 128GB, 3200 MHz
UCS-MP-256GS-B0 Intel® Optane™ Persistent Memory, 256 GB, 3200 MHz
UCS-MP-512GS-B0 Intel® Optane™ Persistent Memory, 512 GB, 3200 MHz
DIMM Blank2
UCS-DIMM-BLK UCS DIMM Blank
Intel® Optane™ Persistent Memory (PMem) Operational Modes
UCS-DCPMM-AD App Direct Mode
UCS-DCPMM-MM Memory Mode
Memory Mirroring Option
N01-MMIRROR3 Memory mirroring option
Notes:
1. All 3rd Generation Intel® Xeon® Scalable Processors (Ice Lake) support PMem products, except 4309Y, 4310,
4310T, and 4316 processor.
2. Any empty DIM M slot must be populated with a DIMM blank to maintain proper cooling airflow.
3. For more memory configuration details, please refer to and UPGRADING or REPLACING CPUs, page 88.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 24
CONFIGURING the SERVER
■ The server supports the following memory reliability, availability, and serviceability (RAS)
BIOS options (only one option can be chosen):
— Adaptive Double Device Data Correction (ADDDC) (default)
— Maximum performance
— Full mirroring
— Partial mirroring
■ For best performance, observe the following:
— When one DIMM is used, it must be populated in DIMM slot 1 (farthest away from the
CPU) of a given channel.
— When single- or dual-rank DIMMs are populated in two DIMMs per channel (2DPC)
configurations, always populate the higher number rank DIMM first (starting from
the farthest slot). For a 2DPC example, first populate with dual-rank DIMMs in DIMM
slot 1. Then populate single-rank DIMMs in DIMM 2 slot.
■ DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically.
■ Cisco memory from previous generation servers (DDR3 and DDR4) is not compatible with the
server.
■ Memory can be configured in any number of DIMMs as pairs, although for optimal
performance, see the following document
■ For additional information, refer to Memory Support for 3rd Generation Intel® Xeon®
Scalable Processors (Ice Lake), page 71.
■ For detailed Intel® Optane™ Persistent Memory (PMem) configurations, refer to the
following document
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/c/hw/c220m6/install/
c220m6.html
25 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Approved Configurations
The DIMMs will be placed by the factory as shown in the following tables.
1 (A1)
2 (A1, E1)
4 (A1, C1); (E1, G1)
6 (A1, C1); (D1, E1); (G1, H1)
8 (A1, C1); (D1, E1); (G1, H1); (B1, F1)
12 (A1, C1); (D1, E1); (G1, H1); (A2, C2); (D2, E2); (G2, H2)
16 (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2, B2); (C2, D2); (E2, F2); (G2, H2)
■ Select 8 or 16 DIMMs per CPU (DIMMs for all CPUs must be configured identically). In
addition, the memory mirroring option (N01-MMIRROR) as shown in Table 6 on page 24 must
be selected.
The DIMMs will be placed by the factory as shown in the following tables.
# DIMMs
CPU 1 DIMM Placement in Channels (for identical ranked DIMMs)
Per CPU
8 (A1, C1); (D1, E1); (G1, H1); (B1, F1)
16 (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2, B2); (C2, D2); (E2, F2); (G2, H2)
■ Select the memory mirroring option (N01-MMIRROR) as shown in Table 6 on page 24.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 26
CONFIGURING the SERVER
The DIMMs will be placed by the factory as shown in the following tables.
CPU 1 DIMM Placement in Channels (for CPU 2 DIMM Placement in Channels (for
#DIMMs
identically ranked DIMMs) identically ranked DIMMs)
1 (A1) (A1)
2 (A1, E1) (A1, E1)
4 (A1, C1); (E1, G1) (A1, C1); (E1, G1)
6 (A1, C1); (D1, E1); (G1, H1) (A1, C1); (D1, E1); (G1, H1)
8 (A1, C1); (D1, E1); (G1, H1); (B1, F1) (A1, C1); (D1, E1); (G1, H1); (B1, F1)
12 (A1, C1); (D1, E1); (G1, H1); (A2, C2); (D2, (A1, C1); (D1, E1); (G1, H1); (A2, C2); (D2,
E2); (G2, H2) E2); (G2, H2)
16 (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2, (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2,
B2); (C2, D2); (E2, F2); (G2, H2) B2); (C2, D2); (E2, F2); (G2, H2)
■ Select 8 or 16 DIMMs per CPU (DIMMs for all CPUs must be configured identically). In
addition, the memory mirroring option (N01-MMIRROR) as shown in Table 6 on page 24 must
be selected.
The DIMMs will be placed by the factory as shown in the following tables.
# DIMMs CPU 1 DIMM Placement in Channels (for CPU 2 DIMM Placement in Channels (for
Per CPU identical ranked DIMMs) identically ranked DIMMs)
8 (A1, C1); (D1, E1); (G1, H1); (B1, F1) (A1, C1); (D1, E1); (G1, H1); (B1, F1)
16 (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2, (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2,
B2); (C2, D2); (E2, F2); (G2, H2) B2); (C2, D2); (E2, F2); (G2, H2)
■ Select the memory mirroring option (N01-MMIRROR) as shown in Table 6 on page 24.
NOTE: System performance is optimized when the DIMM type and quantity are equal
for both CPUs, and when all channels are filled equally across the CPUs in the server.
27 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 7 3200-MHz DIMM Memory Speeds with Different Intel® Xeon® Ice Lake® Processors
DIMM Rules
NOTE:
■ DIMM mixing is not allowed when PMem are installed; in these cases, all DIMMs
must be the same type and size.
■ See the detailed mixing DIMM configurations at the following link
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 28
CONFIGURING the SERVER
See Table 8 for Intel® Optane™ Persistent Memory modes. See Table 8 for allowed DIMM/PMem mixed
configurations.
Table 9 Intel® Whitley® Xeon® Processor Allowable Mixed DIMM/PMem1 Physical Configuration
DIMM +
PMem CPU 1 or CPU 2
Count
8 + 44 DIMM DIMM PMem DIMM DIMM PMem PMem DIMM DIMM PMem DIMM DIMM
8 + 85 DIMM PMem DIMM PMem DIMM PMem DIMM PMem PMem DIMM PMem DIMM PMem DIMM PMem DIMM
NOTE: AD = App Direct Mode, MM = Memory Mode
Notes:
1. All systems must be fully populated with two CPUs when using PMem at this time.
2. AD, MM
3. AD
4. AD, MM
5. AD, MM
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/c/hw/c220m6/install/
c220m6.html
29 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
■ Servers with SATA drives (only) are controlled by an Intel C621 PCH through the SATA
Interposer (AHCI), or
■ SAS/SATA drives are controlled through a Cisco 12G RAID Controller, or
■ SAS/SATA drives are controlled through a Cisco 12G SAS pass-through HBA
■ PCIe drives are controlled directly from the CPUs
NOTE: 64 RAID groups (virtual drives) are supported with this RAID controller.i
■ Use the same capacity for each drive in each RAID volume
■ For the Cisco 12G SAS RAID controller, use either all SAS HDDs, or all SAS SSDs, or all SATA
SSDs in each RAID volume
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 30
CONFIGURING the SERVER
If you do not want the default AHCI 8 SATA-only drive setup (8 internal drives in drive bays 1-8
and 2 SATA M.2 drives), select one of the following:
NOTE:
■ The default solution is AHCI, which supports a limited number of drives,
operating systems, and virtualized environments. For a more comprehensive
solution, choose a controller from Table 10.
■ UCS-M2-HWRAID is required when selecting the M.2 SATA drives.
■ vSAN HCL listed/qualified component is UCSC-SAS-M6T (UCSC-SAS-220M6).
31 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Supercap
UCS-SCAP-M6 M6 Supercap for write cache backup
RAID Configuration Options (not available for Cisco 12G SAS HBA or AHCI)
R2XX-SRAID0 Enable single disk RAID 0 Setting.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 32
CONFIGURING the SERVER
Approved Configurations
■ AHCI supports up to 8 internal SATA HDDs (slots 1-8) with no RAID support.
■ The Cisco 12G RAID SAS controller supports up to 10 internal SAS/SATA SSDs or HDDs with up
to RAID 0, 1, 10, 5, 6, 50, 60 and JBOD mode support.
■ The Cisco 12G SAS HBA supports up to 10 internal drives with JBOD support.
33 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Select Drives
Drive
Product ID (PID) PID Description Capacity
Type
HDDs
HDDs (15K RPM)
UCS-HD900G15K12N 900 GB 12G SAS 15K RPM SFF HDD SAS 900 GB
UCS-HD300G15K12N 300 GB 12G SAS 15K RPM SFF HDD SAS 300 GB
UCS-HD600G15K12N 600 GB 12G SAS 15K RPM SFF HDD SAS 600 GB
HDDs (10K RPM)
UCS-HD300G10K12N 300 GB 12G SAS 10K RPM SFF HDD SAS 300 GB
UCS-HD600G10K12N 600 GB 12G SAS 10K RPM SFF HDD SAS 600 GB
UCS-HD12TB10K12N 1.2 TB 12G SAS 10K RPM SFF HDD SAS 1.2 TB
UCS-HD18TB10K4KN1 1.8 TB 12G SAS 10K RPM SFF HDD (4K) SAS 1.8 TB
UCS-HD24TB10K4KN1 2.4 TB 12G SAS 10K RPM SFF HDD (4K) SAS 2.4 TB
Enterprise Performance SAS/SATA SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day))2
UCS-SD19T63X-EP 1.9 TB 2.5in Enterprise performance 6GSATA SSD(3X endurance) SATA 1.9 TB
UCS-SD960G63X-EP 960 GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) SATA 960 GB
UCS-SD480G63X-EP 480 GB 2.5in Enterprise Performance 6GSATA SSD(3X endurance) SATA 480 GB
UCS-SD19TBM3X-EP 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance) SATA 1.9 TB
UCS-SD960GBM3X-EP 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance) SATA 960 GB
UCS-SD480GBM3X-EP 480GB 2.5in Enterprise Performance 6GSATA SSD(3X endurance) SATA 480 GB
UCS-SD38T63X-EP 3.8TB 2.5in Enter Perf 6G SATA Intel SSD (3X) SATA 3.8 TB
UCS-SD800GK3X-EP 800 GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 800 GB
UCS-SD32TKA3X-EP 3.2TB 2.5in Enter Perf 12G SAS Kioxia G2 SSD (3X) SAS 3.2 TB
UCS-SD16TKA3X-EP 1.6TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 1.6 TB
UCS-SD800GS3X-EP 800GB 2.5in Enter Perf 12G SAS Seagate SSD (3X) SAS 800 GB
UCS-SD16TS3X-EP 1.6TB 2.5in Enter Perf 12G SAS Seagate SSD (3X) SAS 1.6 TB
UCS-SD32TS3X-EP 3.2TB 2.5in Enter Perf 12G SAS Seagate SSD (3X) SAS 3.2 TB
Enterprise Value SAS/SATA SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))3
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 34
CONFIGURING the SERVER
Drive
Product ID (PID) PID Description Capacity
Type
UCS-SD38T6I1X-EV 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD960G6I1X-EV 960 GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCS-SD480G6I1X-EV 480 GB 2.5 inch Enterprise Value 6G SATA SSD SATA 480 GB
UCS-SD19T61X-EV 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9 TB
UCS-SD38T61X-EV 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD960G6S1X-EV 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCS-SD19T6S1X-EV 1.9TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9 TB
UCS-SD76T6S1X-EV 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
UCS-SD240GBM1X-EV 240GB 2.5 inch Enterprise Value 6G SATA SSD SATA 240 GB
UCS-SD480GBM1X-EV 480 GB 2.5 inch Enterprise Value 6G SATA SSD SATA 480 GB
UCS-SD19TBM1X-EV 1.9TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9 TB
UCS-SD76TBM1X-EV 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
UCS-SD38TBM1X-EV 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD19TBM1X-EV 1.9TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9 TB
UCS-SD16TBM1X-EV 1.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.6 TB
UCS-SD960GBM1X-EV 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCS-SD480GBM1X-EV 480GB 2.5 inch Enterprise Value 6G SATA SSD SATA 480 GB
UCS-SD240GBM1X-EV 240GB 2.5 inch Enterprise Value 6G SATA SSD SATA 240 GB
UCS-SD19TM1X-EV 1.9TB 2.5in Enter Value 6G SATA Micron G1 SSD SATA 1.9 TB
UCS-SD960GK1X-EV 960 GB 2.5 inch Enterprise Value 12G SAS SSD SAS 960 GB
UCS-SD15TKA1X-EV 15.3TB 2.5in Enter Value 12G SAS Kioxia G2 SSD SAS 15.3 TB
UCS-SD76TKA1X-EV 7.6TB 2.5 inch Enterprise Value 12G SAS SSD SAS 7.6 TB
UCS-SD38TKA1X-EV 3.8TB 2.5 inch Enterprise Value 12G SAS SSD SAS 3.8 TB
UCS-SD19TKA1X-EV 1.9TB 2.5 inch Enterprise Value 12G SAS SSD SAS 1.9 TB
Self-Encrypted Drives (SED)
UCS-HD24T10NK9 2.4TB 10k rpm 4k SED HDD SED 2.4 TB
UCS-HD18T10NK9 1.8TB 12G SAS 10K RPM SFF HDD (4K format, SED) SED 1.8 TB
UCS-HD12T10NK9 1.2TB 12G SAS 10K RPM SFF HDD (SED-FIPS) SED 1.2 TB
UCS-HD600G15NK9 600GB 12G SAS 15K RPM SFF HDD (SED) SED 600 GB
UCS-SD800GBKNK9 800GB Enterprise Performance SAS SSD (3X DWPD, SED) SED 800 GB
UCS-SD960GBKNK9 960GB Enterprise Value SAS SSD (1X DWPD, SED) SED 960 GB
UCS-SD76TBKNK9 7.6TB Enterprise value SAS SSD (1 DWPD, SED-FIPS) SED- 7.6 TB
FIPS
UCS-SD38TBKNK9 3.8TB Enterprise Value SAS SSD (1X DWPD, SED) SED 3.8 TB
UCS-SD76TEM2NK9 7.6TB Enterprise value SATA SSD (1X, SED) SED 7.6 TB
UCS-SD960GM2NK9 960GB Enterprise value SATA SSD (1X , SED) SED 960 GB
UCS-SD76TBKANK9 7.6TB Enterprise value SAS SSD (1 DWPD, SED-FIPS) SED 7.6 TB
UCS-SD38TBKANK9 3.8TB 2.5in Enterprise value 12G SAS SSD (1DWPD, SED-FIPS) SED 3.8 TB
35 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Drive
Product ID (PID) PID Description Capacity
Type
UCS-SD16TBKANK9 1.6TB 2.5in Enter Perf 12G SAS Kioxia G2 SSD (3X SED-FIPS) SED 1.6 TB
PCIe/NVMe SFF (2.5-inch) SFF drives4
UCS-NVMEI4-I1600 1.6TB 2.5in U.2 Intel P5600 NVMe High Perf Medium Endurance NVMe 1.6 TB
UCS-NVMEXP-I400 400GB 2.5in U.2 Intel P5800X Optane NVMe Extreme Perform SSD NVMe 400 GB
UCS-NVMEXP-I800 800GB 2.5in U.2Intel P5800X Optane NVMe Extreme Perform SSD NVMe 800 GB
UCS-NVME4-1920 1.9TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe NVMe 1,9 TB
UCS-NVME4-3840 3.8TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe NVMe 3.8 TB
UCS-NVME4-7680 7.6TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe NVMe 7.6 TB
UCS-NVME4-1536 15.3TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe NVMe 15.3 TB
UCS-NVME4-1600 1.6TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X) NVMe 1.6 TB
UCS-NVME4-3200 3.2TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X) NVMe 3.2 TB
UCS-NVME4-6400 6.4TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X) NVMe 6.4 TB
UCS-NVMEQ-1536 15.3TB 2.5in U.2 15mm P5316 Hg Perf Low End NVMe NVMe 15.3 TB
UCS-NVMEM6-W3200 3.2TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance NVMe 3.2 TB
UCS-NVMEM6-W7680 7.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance NVMe 7.6 TB
UCS-NVMEM6-W15300 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance NVMe 15.3 TB
UCS-NVMEG4-M960 960GB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance NVMe 960 GB
UCS-NVMEG4-M1920 1.9TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance NVMe 1.9 TB
UCS-NVMEG4-M3840 3.8TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance NVMe 3.8 TB
UCS-NVMEG4-M7680 7.6TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance NVMe 7.6 TB
UCS-NVMEG4-M1536 15.3TB 2.5in U.3 MicronP7450 NVMe High Perf Medium Endurance NVMe 15.3 TB
UCS-NVMEG4-M1600 1.6TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance NVMe 1.6 TB
UCS-NVMEG4-M3200 3.2TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance NVMe 3.2 TB
UCS-NVMEG4-M6400 6.4TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance NVMe 6.4 TB
NOTE: Cisco uses solid state drives from a number of vendors. All solid state drives are subject to physical write limits and
have varying maximum usage limitation specifications set by the manufacturer. Cisco will not replace any solid state drives
that have exceeded any maximum usage specifications set by Cisco or the manufacturer, as determined solely by Cisco.
NOTE: When configuring front facing drives with NVMe drives, you must order an
NVMe cable (PID = CBL-FNVME-220M6) along with the drives.
Caveats
■ With the UCSC-C220-M6S, you can choose only SATA HDDs when using AHCI with a SATA
Interposer. The drives must be installed in slots 1-8.
■ SFF NVMe drives are connected directly to CPU2 and not managed by any drive controller.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 36
CONFIGURING the SERVER
Notes:
1. Operating Systems that support 4k sector size drives are as follows:
- CentOS 7.9/8.2/8.3 (and later)
- Windows Server 2016/2019 (and later)
- Red Hat Enterprise Linux 7.9/8.2 (and later)
- SUSE Linux Enterprise Server 15.2 (and later)
- ESXi 6.7 U3/7.0 U2 (and later)
- See this link for operating system guidance: https://ucshcltool.cloudapps.cisco.com/public/
- UEFI Mode must be used when booting from 4K sector size drives (legacy mode is not supported).
- Ensure that 4K sector size and 512 byte sector size drives are not mixed in the same RAID volume.
2. Targeted for write centric IO applications. Supports endurance of 10 or 3 DWPD (drive writes per day). Target
applications are caching, online transaction processing (OLTP), data warehousing, and virtual desktop infrastructure
(VDI).
3. Targeted for read centric IO applications. Supports endurance of 1 DWPD (drive write per day). Target applications
are boot, streaming media, and collaboration.
4. Except HGST, Intel and WD NVMe drives can be mixed.
■ You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all
SSDs in their own RAID volume.
■ You can mix SAS HDDs and SAS/SATA SSDs when using the Cisco 12G RAID controller or Cisco
12G SAS controller.
■ If you order any NVMe SFF drives, you must also order two CPUs.
■ SFF NVMe drives are bootable in UEFI mode only.
■ SED drives can be mixed with the non-SED drives in Table 11 on page 34.
37 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
NOTE:
■ Intel® VROC is only supported with Intel drives
■ Intel® VROC enablement key factory pre-provisioned to BIOS - no additional licensing
required.
See the instructions on setting up and managing VROC for Intel NVMe SSDs for more
information.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 38
CONFIGURING the SERVER
WARNING: If VIC/MLOM modules are not selected then the product does not
offer any onboard management port capability.
39 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 40
CONFIGURING the SERVER
Notes:
1. HHHL = half-height, half-length; FHHL = full-height, half-length; SS = single-slot; DS = double-slot.
2. Can not be mixed with 1400 series VICs
3. VICs can be placed/installed in riser 1 or 3 only using half height riser combination. For full height, you can use
either card for the VICs.
4. When present, the recommended Fan Speed Control policy setting is balanced.
5. If UCSC-P-I8Q25GF selected then UCSC-GPURKIT-C220 riser is required.
Approved Configurations
■ You can select up to one of the PCIe option cards listed in Table 12 to be installed in Riser 1
and one in Riser 2 if selected. Risers 1 and 2 are controlled by CPU 1. Riser 3 is not installed
in a 1-CPU system.
■ You can select up to two of the PCIe option cards listed in Table 12 for a two-riser system
(Riser 1 and Riser 2 installed) and up to three of the PCIe option cards for a three-riser
system (Riser 1, Riser 2, and Riser 3 installed). Risers 1 and 2 are controlled by CPU 1 and
riser 3 is controlled by CPU 2.
Caveats
41 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 42
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Maximum cards
Product ID (PID) PID Description Card Size
Per node
Notes:
1. Refer to 220 M6 installation guide for more details.
NOTE:
■ All GPU cards must be procured from Cisco as there is a unique SBIOS ID
required by CIMC and UCSM
■ GPUs cannot be mixed.
■ A GPU can be installed in either full-height PCIe riser 1 or 2 (or both) or can be
installed in three half-height riser 1, 2, or 3.
43 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
http://ucspowercalc.cisco.com
WARNING:
■ Starting 1st January 2024, only Titanium rated PSUs are allowed to be shipped to
European Union (EU), European Economic Area (EEA), United Kingdom (UK),
Switzerland and other countries that adopted Lot 9 Regulation.
■ DC PSUs are not impacted by Lot 9 Regulation and are EU/UK Lot 9 compliant
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 44
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
NOTE:
■ In a server with two power supplies, both power supplies must be identical.
■ DC PSUs are not impacted by Lot 9 Regulation and are EU/UK Lot 9 compliant
45 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
NOTE: Table 15 lists the power cords for servers that use power supplies less than
2300 W. Table 16 lists the power cords for servers that use 2300 W power supplies.
Note that the power cords for 2300 W power supplies use a C19 connector so they
only fit the 2300 W power supply connector.
Table 15 Available Power Cords (for server PSUs less than 2300 W)
Connector:
IEC60320/C13
186570
CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 46
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Table 15 Available Power Cords (for server PSUs less than 2300 W)
186571
CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug,
Australia
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)
186580
(BS 1363A) 13 AMP fuse
186576
CAB-250V-10A-ID Power Cord, 250V, 10A, India
OVE
Connector:
EL 701
187490
Connector:
Plug: EL 701B
EL 212 (IEC60320/C13)
186574
(SI-32)
47 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Table 15 Available Power Cords (for server PSUs less than 2300 W)
186575
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
Cordset rating: 10 A, 250 V
Plug: Length: 8 ft. 2 in (2.5 m)
MP232-R
Connector:
IEC 60320 C15
186578
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)
186580
(BS 1363A) 13 AMP fuse
2,133.6 ± 25
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 48
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
CAB-C19-CBN Cabinet Jumper Power Cord, 250 VAC 16A, Not applicable
C20-C19 Connectors
CAB-9K16A-BRZ Power Cord 250VAC 16A, Brazil, Src Plug Image not available
EL224-C19
CAB-9K16A-KOR Power Cord 250VAC 16A, Korea, Src Plug Image not available
CAB-AC-16A-AUS Power Cord, 250VAC, 16A, Australia C19 Image not available
CAB-AC-C19-TW Power Cord, 250 V, 16A, C19, Taiwan Image not available
CAB-AC-C6K-TWLK Power Cord, 250Vac 16A, twist lock NEMA Image not available
L6-20 plug, US
CAB-C19-C20-3M-JP Power Cord C19-C20, 3M/10ft Japan PSE mark Image not available
UCSB-CABL-C19-BRZ NBR 14136 to C19 AC 14FT POWER CORD, Image not available
BRAZIL
NO-POWER-CORD ECO friendly green option, no power cable Image not available
will be shipped
R2XX-DMYMPWRCORD No power cord option Not valid for delivery Image not available
destination in Argentina, Brazil, Japan
49 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
The reversible cable management arm mounts on either the right or left slide rails at the rear of
the server and is used for cable management. Use Table 18 to order a cable management arm.
For more information about the tool-less rail kit and cable management arm, see the Cisco UCS
C220 M6 Installation and Service Guide at this URL:
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/c/hw/c220m6/install/
c220m6.html
NOTE: If you plan to rackmount your UCS C220 M6 server, you must order a tool-less
rail kit.The same rail kits and CMAs are used for M5 and M6 servers.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 50
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
To change the default NIC mode to Dedicated, select the UCSC-DLOM-01 PID shown in Table 19.
In Dedicated NIC mode, the CIMC can be accessed only through the dedicated management port.
See Chassis Rear View (two full-height, 3/4-length PCIe risers), page 11 for the location of
the management port.
To change the default NIC mode to Cisco Card Mode, select the UCSC-CCARD-01 PID shown in
Table 19. In this mode, you can assign an IP address to the CIMC using DHCP and from there you
can fully automate your deployment.
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C480M5/install/C480M
5/C480M5_chapter_010.html#concept_srqj_vsr_fz
51 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 52
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
A chassis intrusion switch gives a notification of any unauthorized mechanical access into the
server.
Notes:
1. Please note that Microsoft certification requires a TPM 2.0 for bare-metal or guest VM deployments. Opt-out of
the TPM 2.0 voids the Microsoft certification.
NOTE:
■ The TPM module used in this system conforms to TPM 2.0, as defined by the
Trusted Computing Group (TCG). It is also SPI-based.
■ TPM installation is supported after-factory. However, a TPM installs with a
one-way screw and cannot be replaced, upgraded, or moved to another server. If
a server with a TPM is returned, the replacement server must be ordered with a
new TPM.
53 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 54
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Each boot-optimized RAID controller can accommodate up to two SATA M.2 SSDs shown in
Table 23.
Order the UCS-M2-HWRAID Boot-Optimized RAID controller from Table 24. The Boot-Optimized
RAID controller plugs into a connector on the motherboard and holds up to two M.2 SATA drives.
NOTE: The Boot-Optimized RAID controller supports Windows and Linux Operating
Systems
UCS-M2-HWRAID Cisco Boot optimized M.2 RAID controller (holds up to two M.2 SATA SSDs)
NOTE:
■ The UCS-M2-HWRAID boot-optimized RAID controller supports RAID 1 and JBOD mode
■ CIMC is supported for configuring of volumes and monitoring of the controller and
installed SATA M.2 drives
■ The minimum version of Cisco IMC and Cisco UCS Manager that supports this
controller is 4.2(1) and later. The name of the controller in the software is MSTOR-RAID
■ The SATA M.2 drives can boot in UEFI mode only. Legacy boot mode is not supported
■ Hot-plug replacement is not supported. The server must be powered off.
55 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Caveats
■ Order one or two identical M.2 SATA SSDs for the boot-optimized RAID controller. You cannot
mix M.2 SATA SSD capacities.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 56
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
NOTE:
■ See this link for operating system guidance:
https://ucshcltool.cloudapps.cisco.com/public/
Select
MSWS-19-ST16C-NS Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC
MSWS-22-ST16C-NS Windows Server 2022 Standard (16 Cores/2 VMs) - No Cisco SVC
Red Hat
RHEL-2S2V-1A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req
RHEL-2S2V-3A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req
RHEL-2S2V-5A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req
RHEL-VDC-2SUV-1A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr Supp Req
RHEL-VDC-2SUV-3A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr Supp Req
57 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
RHEL-VDC-2SUV-5A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 5 Yr Supp Req
RHEL-2S2V-1S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1-Yr SnS
RHEL-2S2V-3S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3-Yr SnS
RHEL-VDC-2SUV-1S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr SnS Reqd
RHEL-VDC-2SUV-3S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr SnS Reqd
RHEL-SAP-2S2V-1S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS
RHEL-SAP-2S2V-3S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS
SUSE
SLES-2S2V-1A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req
SLES-2S2V-3A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req
SLES-2S2V-5A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req
SLES-2S2V-1S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS
SLES-2S2V-3S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS
SLES-2S2V-5S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS
SLES-2S-HA-1S SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS
SLES-2S-HA-3S SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS
SLES-2S-HA-5S SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS
SLES-2S-GC-1S SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns
SLES-2S-GC-3S SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS
SLES-2S-GC-5S SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS
SLES-2S-LP-1S SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required
SLES-2S-LP-3S SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required
SLES-2S-LP-1A SUSE Linux Live Patching Add-on (1-2 CPU); 1yr Support Req
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 58
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
SLES-2S-LP-3A SUSE Linux Live Patching Add-on (1-2 CPU); 3yr Support Req
SLES-2SUVM-1A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 1Y Supp Req
SLES-2SUVM-1S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 1Y SnS
SLES-2SUVM-1YR SUSE Linux Entp Svr (1-2 CPU,Unl VM) LP; Prio SnS 24x7 - 1Y
SLES-2SUVM-3A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 3Y Supp Req
SLES-2SUVM-3S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 3Y SnS
SLES-2SUVM-3YR SUSE Linux Entp Svr (1-2 CPU,Unl VM) LP; Prio SnS 24x7 - 3Y
SLES-2SUVM-5A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 5Y Supp Req
SLES-2SUVM-5S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 5Y SnS
SLES-2SUVM-5YR SUSE Linux Entp Svr (1-2 CPU,Unl VM) LP; Prio SnS 24x7 - 5Y
SLES-SAP2SUVM-1A SLES for SAP Apps w/ HA (1-2 CPU, Unl VM) LP; 1Y Supp Reqd
SLES-SAP2SUVM-1S SLES for SAP Apps (1-2 CPU, Unl VM) LP; Priority 1Y SnS
SLES-SAP2SUVM-1YR SUSE for SAP Apps; (1-2 CPU,Unl VM) LP; Prio SnS 24x7 - 1Y
SLES-SAP2SUVM-3A SLES for SAP Apps w/ HA (1-2 CPU, Unl VM) LP; 3Y Supp Reqd
SLES-SAP2SUVM-3S SLES for SAP Apps (1-2 CPU, Unl VM) LP; Priority 3Y SnS
SLES-SAP2SUVM-3YR SUSE for SAP Apps; (1-2 CPU,Unl VM) LP; Prio SnS 24x7 - 3Y
SLES-SAP2SUVM-5A SLES for SAP Apps w/ HA (1-2 CPU, Unl VM) LP; 5Y Supp Reqd
SLES-SAP2SUVM-5S SLES for SAP Apps (1-2 CPU, Unl VM) LP; Priority 5Y SnS
SLES-SAP2SUVM-5YR SUSE for SAP Apps; (1-2 CPU,Unl VM) LP; Prio SnS 24x7 - 5Y
SLES-SAP-2S2V-1A SLES for SAP Apps (1-2 CPU, 1-2 VM); 1-Yr Support Reqd
SLES-SAP-2S2V-3A SLES for SAP Apps (1-2 CPU, 1-2 VM); 3-Yr Support Reqd
SLES-SAP-2S2V-5A SLES for SAP Apps (1-2 CPU, 1-2 VM); 5-Yr Support Reqd
SLES-SAP-2S2V-1S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS
SLES-SAP-2S2V-3S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS
SLES-SAP-2S2V-5S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS
59 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
NV-GRDWK-1-5S Quadro Perpetual Lic - NVIDIA vDWS 1CCU; 5Yr SUMS Req
NV-GRDVA-1-5S GRID Perpetual Lic - NVIDIA VDI APPs 1CCU; 5Yr SUMS Reqd
NV-GRDPC-1-5S GRID Perpetual Lic - NVIDIA VDI PC 1CCU; 5Yr SUMS Reqd
NV-GRD-EDP-5S EDU - Quadro Perpetual Lic - NVIDIA vDWS 1CCU; 5Yr SUMS Reqd
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 60
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES
Table 27 OS Media
MSWS-19-ST16C-RM Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-19-DC16C-RM Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only
MSWS-22-ST16C-RM Windows Server 2022 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-22-DC16C-RM Windows Server 2022 DC (16Cores/Unlim VM) Rec Media DVD Only
61 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
Chassis
Internal views of the C220 M6 chassis with the top cover removed are shown in Figure 7 and
Figure 8 on page 64.
Figure 7 C220 M6 SFF With Top Cover Off (full-height, full-width PCIe cards)
1 2 3 4 5 6 7 8
10
11
309137
13 3 12
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 62
SUPPLEMENTAL MATERIAL
63 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
An internal view of the C220 M6 chassis with the top cover removed is shown in Figure 8.
Figure 8 C220 M6 SFF With Top Cover Off (full-height, half-width PCIe cards)
1 2 3 4 5 6 7 8
10
11
12
309138
14 3 13
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 64
SUPPLEMENTAL MATERIAL
Risers
Figure 9 shows the locations of the PCIe riser connectors on the C220 M6 SFF motherboard. The
allowed configurations are:
Riser 3 Connector
Riser 2 Connector
Riser 1 Connector
65 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Figure 10 shows three half-height risers plugged into their respective connectors.
Riser 3 Connector
Half-Height Riser 3
Half-Height Riser 2
Half-Height Riser 1
Riser 1 Connector
Riser 2 Connector
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 66
SUPPLEMENTAL MATERIAL
Figure 11 shows two full-height risers plugged in. Note that riser 1 is plugged into the riser 1
connector and riser 2 is plugged into the riser 3 connector. Riser 2 connector is not used.
Riser 3 Connector
Full-Height Riser 2
FullHeight Riser 1
Riser 1 Connector
67 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Block Diagram
A block diagram of the C220 M6S and C220 M6SN is shown in Figure 12.
. . . . . . . . . . . .
UCSC-C220-M6S DDR4 DIMMs
Network connectors
OPTION 2 A1 A2
Front drives 1-10
Chan A
SAS/SATA only DMI3
1 B1 B2
mLOM
2 Chan B Module
3 12G RAID
CPU1 PCIe 4.0 x 16
4 Drive Controller C1 C2
SAS/SATA PCIe 4.0 x 8
5 Backplane or 12G SAS Chan C PCIe 4.0 x 16
6 HBA CPU1
7 D1 D2
8 Chan D
9 3rd Gen Intel®
10 E1 E2 Xeon® Scalable
UCSC-C220-M6S Chan E Processor (Ice Lake) Front Panel
KVM
OPTION 3 CPU2 PCIe 4.0 x 16 (for 4 NVMe drives) Connector
Front drives F1 F2
1-4 SAS/SATA or NVMe Chan F
5-10 SAS/SATA only
1 NVMe USB 2.0 x 1
. G1 G2
2 1 VGA
. Chan G
3 . 1 Serial COM
4 NVMe 12G RAID CPU1 PCIe 4.0 x 8
H1 H2
SAS/SATA
Drive Controller (for SAS/SATA drives)
5 Backplane or 12G SAS Chan H
6 .
.
HBA
7
8 .
UPI (3x11.2 GT/s) NOTE: Only one riser configuration is possible at a time
9 SAS/SATA DDR4 DIMMs
10 A1 A2 PCIe Riser 1 (1 HH slot)
Chan A PCIe 4.0 x 16 Slot 1
1 HH Riser Configuration
B1 B2 PCIe 4.0 x 16
UCSC-C220-M6N
Front drives 1-10 Chan B
all NVMe CPU2
PCIe 4.0 x 16 C1 C2 PCIe Riser 1 (1 HH slot)
1 NVMe
. Chan C Slot 1
PCIe 4.0 x 16
2 . CPU2
3 . CPU2 D1 D2
4 . Drive PCIe 4.0 x 8 Chan D PCIe Riser 2 (1 HH slot)
5 . Backplane 3rd Gen Intel®
6 . Xeon® Scalable PCIe 4.0 x 16 Slot 1
E1 E2 3 HH Riser Configuration
7 .
. Chan E Processor (Ice Lake)
8
9 CPU1
NVMe F1 F2 PCIe Riser 3 (1 HH slot)
PCIe 4.0 x 16
10
Chan F PCIe 4.0 x 16 Slot 1
G1 G2
Chan G
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 68
SUPPLEMENTAL MATERIAL
Pin Signal
1 RTS (Request to Send)
2 DTR (Data Terminal Ready)
3 TxD (Transmit Data)
4 GND (Signal Ground)
5 GND (Signal Ground)
6 RxD (Receive Data)
7 DSR (Data Set Ready)
8 CTS (Clear to Send)
69 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
KVM Cable
The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for
a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct
connection to the operating system and the BIOS running on the server.
2 DB-9 serial connector 4 Two-port USB connector (for a mouse and keyboard)
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 70
SUPPLEMENTAL MATERIAL
Memory Support for 3rd Generation Intel® Xeon® Scalable Processors (Ice
Lake)
PMem Support
The Ice Lake CPUs support two memory modes:
For example, if App Direct mode is configured and the DIMM sockets for a CPU are populated with 8 x 128
GB DRAMs (1 TB total DRAM) and 8 x 512 GB PMem (4 TB total PMem), then 5 TB total counts towards the
CPU capacity limit. Follow the Intel recommended DRAM:PMem ratio for App Direct Mode.
Memory Mode
PMem operates as a 100% memory module. Data is volatile and DRAM acts as a cache for PMem. Only the
PMem capacity counts towards the CPU capacity limit. This is the factory default mode.
For example, if Memory mode is configured and the DIMM sockets for a CPU are populated with 8 x 128 GB
DRAMs (1 TB total DRAM) and 8 x 512 GB PMem (4 TB total PMem), then only 4 TB total (the PMem memory)
counts towards the CPU capacity limit. All of the DRAM capacity (1 TB) is used as cache and does not factor
into CPU capacity. The recommended Intel DRAM:PMem ratio for Memory Mode is 1:4, 1:8, or 1:16
Only the following mixed DRAM/PMem memory configurations are supported per CPU socket:
■ 4 DRAMs and 4 PMem, or 8 DRAMs and 4 PMem, or 8 DRAMs and 1 PMem, or 8 DRAMs and 8 PMem
The available PMem capacities are 128 GB, 256 GB, or 512 GB
https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-c-series-rack-s
ervers/memory-guide-c220-c240-b200-m6.pdf
71 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
SPARE PARTS
This section lists the upgrade and service-related parts for the UCS C220 M6 server. Some of these parts are
configured with every server.
NOTE: Some spare parts you order may also require accessories for full
functionality. For example, drives or RAID controllers may need accompanying
cables. CPUs may need heatsinks, thermal paste, and installation tools. The spares
and their accessory parts are listed in Table 29.
KVM Cable
Risers
CPUs
Note: If you are ordering a second CPU, see the CPU Accessories section in this table for additional parts
you may need to order for the second CPU.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 72
SPARE PARTS
73 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
CPU Accessories
UCS-CPU-TIM= Single CPU thermal interface material syringe for M5 server HS seal5
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 74
SPARE PARTS
Memory
DIMM Blank
HDDs
Note: When ordering additional SAS/SATA or NVMe front or rear drives, you may need to order a cable to
connect from the drive to the motherboard. See the Drive Cables section in this table.
Enterprise Performance SAS/SATA SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per
day))
75 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
UCS-SD32TKA3X-EP= 3.2TB 2.5in Enter Perf 12G SAS Kioxia G2 SSD (3X)
UCS-SD800GS3X-EP= 800GB 2.5in Enter Perf 12G SAS Seagate SSD (3X)
UCS-SD16TS3X-EP= 1.6TB 2.5in Enter Perf 12G SAS Seagate SSD (3X)
UCS-SD32TS3X-EP= 3.2TB 2.5in Enter Perf 12G SAS Seagate SSD (3X)
Enterprise Value SAS/SATA SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 76
SPARE PARTS
UCS-HD18T10NK9= 1.8TB 12G SAS 10K RPM SFF HDD (4K format, SED)
UCS-SD38TBKANK9= 3.8TB 2.5in Enterprise value 12G SAS SSD (1DWPD, SED-FIPS)
UCS-SD16TBKANK9= 1.6TB 2.5in Enter Perf 12G SAS Kioxia G2 SSD (3X SED-FIPS)
UCS-NVMEI4-I1600= 1.6TB 2.5in U.2 Intel P5600 NVMe High Perf Medium Endurance
UCS-NVMEXP-I400= 400GB 2.5in U.2 Intel P5800X Optane NVMe Extreme Perform SSD
UCS-NVMEXP-I800= 800GB 2.5in U.2Intel P5800X Optane NVMe Extreme Perform SSD
UCS-NVME4-1920= 1.9TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe
UCS-NVME4-3840= 3.8TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe
UCS-NVME4-7680= 7.6TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe
UCS-NVME4-1536= 15.3TB 2.5in U.2 15mm P5520 Hg Perf Med End NVMe
UCS-NVME4-1600= 1.6TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X)
UCS-NVME4-3200= 3.2TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X)
UCS-NVME4-6400= 6.4TB 2.5in U.2 15mm P5620 Hg Perf Hg End NVMe (3X)
UCS-NVMEQ-1536= 15.3TB 2.5in U.2 15mm P5316 Hg Perf Low End NVMe
UCS-NVMEM6-W3200= 3.2TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance
UCS-NVMEM6-W7680 = 7.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance
77 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
UCS-NVMEM6-W15300= 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance
UCS-NVMEG4-M960= 960GB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1920= 1.9TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M3840= 3.8TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M7680= 7.6TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1536= 15.3TB 2.5in U.3 MicronP7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1600= 1.6TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
UCS-NVMEG4-M3200= 3.2TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
UCS-NVMEG4-M6400= 6.4TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
Drive Cables
UCS-M2-HWRAID= Cisco Boot optimized M.2 RAID controller (holds up to two M.2 SATA SSDs)
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 78
SPARE PARTS
RAID Controller
UCSC-M-V25-04= Cisco UCS VIC 1467 quad port 10/25G SFP28 mLOM
UCSC-M-V100-04= Cisco UCS VIC 1477 dual port 40/100G QSFP28 mLOM
UCSC-M-V5Q50GV2= Cisco UCS VIC 15427 Quad Port CNA MLOM with Secure Boot
OCP
UCSC-PCIE-C100-04= Cisco UCS VIC 1495 Dual Port 40/100G QSFP28 CNA PCIe
UCSC-PCIE-C25Q-04= Cisco UCS VIC 1455 quad port 10/25G SFP28 PCIe
1 Gb NICs
10 Gb NICs
25 Gb NICs
79 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
40 Gb NICs
100 Gb NICs
UCSC-9500-8E= 9500 Series PCIe Gen 4.0 Tri-Mode Storage HBA 12Gb/s SAS/SATA/PCIe
(NVMe)
SATA Interposer
Note: If you are adding a GPU, you may need the NVIDIA license. See the NVIDIA GPU Licenses section of
this table.
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 80
SPARE PARTS
NV-GRDWK-1-5S= Quadro Perpetual Lic - NVIDIA vDWS 1CCU; 5Yr SUMS Req
NV-GRDVA-1-5S= GRID Perpetual Lic - NVIDIA VDI APPs 1CCU; 5Yr SUMS Reqd
NV-GRDPC-1-5S= GRID Perpetual Lic - NVIDIA VDI PC 1CCU; 5Yr SUMS Reqd
NV-GRD-EDP-5S= EDU - Quadro Perpetual Lic - NVIDIA vDWS 1CCU; 5Yr SUMS Reqd
81 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 82
SPARE PARTS
NV-GRD-VA2WKP-5S= Upgrade NVIDIA VDI APPs to Quadro vDWS 1CCU; 5Yr SUMS Reqd
NV-GRD-VA2PCP-5S= Upgrade NVIDIA VDI APPs to vPC 1CCU; 5Yr SUMS Reqd
NV-GRD-VA2WKPE-5S= Upgrade NVIDIA VDI to Quadro vDWS 1CCU; 5Yr SUMS Reqd
NV-GRD-PC2WKP-5S= Upgrade NVIDIA vPC to Quadro vDWS 1CCU; 5Yr SUMS Reqd
NV-GRD-PC2WKPE-5S= Upgrade NVIDIA vPC to Quadro vDWS 1CCU; 5Yr SUMS Reqd
Power Supplies
UCSC-PSUV2-1050DC= Cisco UCS 1050W -48V DC Power Supply for Rack Server Requires cable
CAB-48DC-40A-8AWG
UCSC-PSUV21050D6I= 1050W -48V DC power supply for C-Series servers (India) Requires cable
CAB-48DC-40A-8AWG
UCSC-PSUV2-1050DC= Cisco UCS 1050W -48V DC Power Supply for Rack Server Requires cable
CAB-48DC-40A-8AWG
UCSC-PSUV21050D6I= 1050W -48V DC power supply for C-Series servers (India) Requires cable
CAB-48DC-40A-8AWG
UCSC-PSU1-1050ELV= 1050W AC PSU Enhanced Low Line (Not EU/UK Lot 9 Compliant)
Platinum
Power Cables
CAB-48DC-40A-8AWG= C-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A
83 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
CAB-48DC-40A-AS= C-Series -48VDC PSU PWR Cord, 3.5M, 3Wire, 8AWG, 40A (AS/NZ)
CAB-C13-CBN = Cabinet Jumper Power Cord, 250 VAC 10A, C14-C13 Connectors
CAB-C19-CBN= Cabinet Jumper Power Cord, 250 VAC 16A, C20-C19 Connectors AC
CAB-48DC-40A-INT= C-Series -48VDC PSU PWR Cord, 3.5M, 3 Wire, 8AWG, 40A (INT)
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 84
SPARE PARTS
CAB-9K12A-NA= N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North America, 2.5m
CAB-AC-C6K-TWLK= Power Cord, 250Vac 16A, twist lock NEMA L6-20 plug, US
Rail Kit
UCSC-RAIL-M6= Ball Bearing Rail Kit for C220 and C240 M6 rack servers
CMA
Security
UCS-TPM-002D TPM 2.0 TCG FIPS140-2 CC+ Cert M6 Intel MSW2022 Compliant
Bezel
85 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
Software/Firmware
MSWS-19-ST16C-RM= Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-19-DC16C-RM= Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only
MSWS-22-ST16C-RM= Windows Server 2022 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-22-DC16C-RM= Windows Server 2022 DC (16Cores/Unlim VM) Rec Media DVD Only
RHEL SAP
Notes:
1. Can be selected with quantity 1 or 2 CPUs. It is recommended that the user purchase 2 QTY of Processor to
support Riser2 FH x16 Slot. Full-height Riser 1 is controlled from CPU1 and Riser 2 is controlled from CPU2.
2. The maximum number of UCS-CPU-I8351N CPUs is one
3. The maximum number of UCS-CPU-I6314U CPUs is one
4. The maximum number of UCS-CPU-I6312U CPUs is one
5. This part is included with the purchase of option or spare CPU or CPU processor kits.
6. The 2300 W power supply uses a different power connector that the rest of the power supplies, so you must use
different power cables to connect it. See Table 15 on page 46 and Table 16 on page 49.
Please refer to “Cisco UCS C220 M6 Server Installation and Service Guide” for installation procedures. See
this link:
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/c/hw/c220m6/install/
c220m6.html
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 86
UPGRADING or REPLACING CPUs
(1) Have the following tools and materials available for the procedure:
Carefully remove and replace the CPU and heatsink in accordance with the instructions
found in “Cisco UCS C220 M6 Server Installation and Service Guide,” found at:
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/c/hw/c220m6/install/
c220m6.html
(1) Have the following tools and materials available for the procedure:
(3) Order one heat sink for each new CPU. Order PID UCSC-HSLP-M6=.
Carefully install the CPU and heatsink in accordance with the instructions found in “Cisco
UCS C220 M6 Server Installation and Service Guide,” found at:
87 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
UPGRADING or REPLACING MEMORY
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/c/hw/c220m6/install/
c220m6.html
Step 2 Press evenly on both ends of the DIMM until it clicks into place in its slot
Note: Ensure that the notch in the DIMM aligns with the slot. If the notch is misaligned, it is
possible to damage the DIMM, the slot, or both.
Step 3 Press the DIMM connector latches inward slightly to seat them fully.
Step 4 Populate all slots with a DIMM or DIMM blank. A slot cannot be empty.
1
3
2
4
1
306040
For additional details on replacing or upgrading DIMMs and PMem, see “Cisco UCS C220 M6
Server Installation and Service Guide,” found at this link:
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/c/hw/c220m6/install/
c220m6.html
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 88
DISCONTINUED EOL PRODUCTS
Table 30 EOS
Product ID Description EOL/EOS link
software
NV-GRDVA-1-4S GRID Perpetual Lic - NVIDIA VDI https://www.cisco.com/c/en/us/products/collateral/se
APPs 1CCU; 4Yr SUMS Reqd rvers-unified-computing/ucs-b-series-blade-servers/sele
ct-commvault-veeam-vmware-nvdia-mapr-software-rese
ll-eol.html
NV-GRDPC-1-4 GRID Perpetual Lic - NVIDIA VDI https://www.cisco.com/c/en/us/products/collateral/se
PC 1CCU; 4Yr SUMS Reqd rvers-unified-computing/ucs-b-series-blade-servers/sele
ct-commvault-veeam-vmware-nvdia-mapr-software-rese
ll-eol.html
NV-GRDWK-1-4S Quadro Perpetual Lic - NVIDIA https://www.cisco.com/c/en/us/products/collateral/se
vDWS 1CCU; 4Yr SUMS Req rvers-unified-computing/ucs-b-series-blade-servers/sele
ct-commvault-veeam-vmware-nvdia-mapr-software-rese
ll-eol.html
NV-GRD-EDP-4S EDU - Quadro Perpetual Lic - https://www.cisco.com/c/en/us/products/collateral/se
NVIDIA vDWS 1CCU; 4Yr SUMS rvers-unified-computing/ucs-b-series-blade-servers/sele
Reqd ct-commvault-veeam-vmware-nvdia-mapr-software-rese
ll-eol.html
NV-GRID-VAP-4YR NVIDIA GRID Production SUMS - https://www.cisco.com/c/en/us/products/collateral/se
VDI Apps 1CCU - 4 Year rvers-unified-computing/ucs-b-series-blade-servers/sele
ct-commvault-veeam-vmware-nvdia-mapr-software-rese
ll-eol.html
NV-GRID-PCP-4YR NVIDIA GRID Production SUMS - https://www.cisco.com/c/en/us/products/collateral/se
VDI PC 1CCU - 4 Year rvers-unified-computing/ucs-b-series-blade-servers/sele
ct-commvault-veeam-vmware-nvdia-mapr-software-rese
ll-eol.html
NV-GRID-WKP-4YR NVIDIA Quadro Production SUMS - https://www.cisco.com/c/en/us/products/collateral/se
vDWS 1CCU - 4 Year rvers-unified-computing/ucs-b-series-blade-servers/sele
ct-commvault-veeam-vmware-nvdia-mapr-software-rese
ll-eol.html
NV-GRID-EDP-4YR EDU - NVIDIA Quadro vDWS https://www.cisco.com/c/en/us/products/collateral/se
Production SUMS - 1CCU - 4 Year rvers-unified-computing/ucs-b-series-blade-servers/sele
ct-commvault-veeam-vmware-nvdia-mapr-software-rese
ll-eol.html
Operating system
SLES-2SUV-1A SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); 1-Yr Support Req
SLES-2SUV-1S SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); Prio 1-Yr SnS
SLES-2SUV-3A SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); 3-Yr Support Req
SLES-2SUV-3S SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); Prio 3-Yr SnS
SLES-2SUV-5A SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); 5-Yr Support Req
SLES-2SUV-5S SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); Prio 5-Yr SnS
89 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
Table 30 EOS
SLES-SAP-2SUV-1A SLES for SAP Apps w/ HA (1-2
CPU, Unl VM); 1-Yr Support Reqd
SLES-SAP-2SUV-1S SLES for SAP Apps (1-2 CPU, Unl
VM); Priority 1-Yr SnS
SLES-SAP-2SUV-3A SLES for SAP Apps w/ HA (1-2
CPU, Unl VM); 3-Yr Support Reqd
SLES-SAP-2SUV-3S SLES for SAP Apps (1-2 CPU, Unl
VM); Priority 3-Yr SnS
SLES-SAP-2SUV-5A SLES for SAP Apps w/ HA (1-2
CPU, Unl VM); 5-Yr Support Reqd
SLES-SAP-2SUV-5S SLES for SAP Apps (1-2 CPU, Unl
VM); Priority 5-Yr SnS
Drives
UCS-M2-240GB 240GB M.2 SATA Micron G1 SSD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-M2-960GB 960GB M.2 SATA Micron G1 SSD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-NVMEI4-I3840 3.8TB 2.5in U.2 Intel P5500 NVMe https://www.cisco.com/c/en/us/products/collate
High Perf Medium Endurance ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-access-eol-15074.html
UCS-NVMEI4-I7680 7.6TB 2.5in U.2 Intel P5500 NVMe https://www.cisco.com/c/en/us/products/collate
High Perf Medium Endurance ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-access-eol-15074.html
UCS-NVMEM6-W6400 6.4TB 2.5in U.2 WD SN840 NVMe https://www.cisco.com/c/en/us/products/collate
Extreme Perf. High Endurance ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD76T61X-EV 7.6TB 2.5 inch Enterprise Value https://www.cisco.com/c/en/us/products/collate
6G SATA SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hyperflex-accessories-eol2.html
UCS-SD76TBEM2NK9 7.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD (SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD960GBM2NK9 960GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD (SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD240GM1X-EV 240GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD480GM1X-EV 480 GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD76TM1X-EV 7.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD16TM1X-EV 1.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 90
DISCONTINUED EOL PRODUCTS
Table 30 EOS
UCS-SD38TM1X-EV 3.8TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD960G61X-EV 960GB 2.5 inch Enterprise Value https://www.cisco.com/c/en/us/products/collate
6G SATA SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hyperflex-accessories-eol2.html
UCS-NVMEI4-I6400 6.4TB 2.5in U.2 Intel P5600 NVMe https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-b-series-blade-s
High Perf Medium Endurance ervers/select-ucs-accessories-eol.html
UCS-SD32TK3X-EP 3.2TB 2.5in Enter Perf 12G SAS https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-b-series-blade-s
Kioxia G1 SSD (3X) ervers/select-ucs-accessories-eol.html
UCS-SD38TK1X-EV 3.8TB 2.5in Enter Value 12G SAS https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-b-series-blade-s
Kioxia G1 SSD ervers/select-ucs-accessories-eol.html
UCS-SD76TBKNK9 7.6TB 2.5in Enter Value 12G SAS https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-b-series-blade-s
Kioxia G1 SSD (SED-FIPS) ervers/select-ucs-accessories-eol.html
UCS-SD76TK1X-EV 7.6TB 2.5in Enter Value 12G SAS https://www.cisco.com/c/en/us/products/collate
Kioxia G1 SSD ral/servers-unified-computing/ucs-b-series-blade-s
ervers/select-ucs-accessories-eol.html
UCS-SD15TK1X-EV 15.3TB 2.5in Enter Value 12G SAS https://www.cisco.com/c/en/us/products/collate
Kioxia G1 SSD ral/servers-unified-computing/ucs-b-series-blade-s
ervers/select-ucs-accessories-eol.html
UCS-SD16TBKNK9 1.6TB 2.5in Enter Perf 12G SAS https://www.cisco.com/c/en/us/products/collate
Kioxia G1 SSD (3X SED-FIPS) ral/servers-unified-computing/ucs-b-series-blade-s
ervers/select-ucs-accessories-eol.html
UCS-SD16TK3X-EP 1.6TB 2.5in Enter Perf 12G SAS https://www.cisco.com/c/en/us/products/collate
Kioxia G1 SSD (3X) ral/servers-unified-computing/ucs-b-series-blade-s
ervers/select-ucs-accessories-eol.html
UCS-SD19TK1X-EV 1.9TB 2.5in Enter Value 12G SAS https://www.cisco.com/c/en/us/products/collate
Kioxia G1 SSD ral/servers-unified-computing/ucs-b-series-blade-s
ervers/select-ucs-accessories-eol.html
UCS-NVMEI4-I1920 1.9TB 2.5in U.2 Intel P5500 NVMe https://www.cisco.com/c/en/us/products/collate
High Perf Medium Endurance ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-access-eol-15074.html
UCS-NVMEI4-I3200 3.2TB 2.5in U.2 Intel P5600 NVMe https://www.cisco.com/c/en/us/products/collate
High Perf Medium Endurance ral/servers-unified-computing/ucs-b-series-blade-s
ervers/select-ucs-accessories-eol.html
UCS-SD120GM1X-EV 120 GB 2.5 inch Enterprise Value https://www.cisco.com/c/en/us/products/collate
6G SATA SSD ral/servers-unified-computing/ucs-b-series-blade-s
ervers/select-ucs-accessories-eol.html
UCS-SD19TS1X-EV 1.9TB 2.5v Enter Value 12G SAS https://www.cisco.com/c/en/us/products/collate
Seagate SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hci-accessories-eol.html
UCS-SD38T6S1X-EV 3.8TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Samsung SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hci-accessories-eol.html
UCS-SD960GS1X-EV 960GB 2.5in Enter Value 12G SAS https://www.cisco.com/c/en/us/products/collate
Seagate SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hci-accessories-eol.html
91 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
DISCONTINUED EOL PRODUCTS
Table 30 EOS
UCSC-NVMEXP-I750 750GB 2.5in Intel Optane NVMe https://www.cisco.com/c/en/us/products/collate
Extreme Perf. ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hci-accessories-eol.html
UCSC-NVMEXPB-I375 375GB 2.5in Intel Optane NVMe https://www.cisco.com/c/en/us/products/collate
Extreme Performance SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-hci-accessories-eol.html
PCIe Cards
UCSC-M-V5D200G Cisco VIC 15238 2x 40/100/200G https://www.cisco.com/c/en/us/products/collate
mLOM C-Series ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-ucsx-accessories-eol.html
UCSC-M-V5Q50G Cisco VIC 15428 4x 10/25/50G https://www.cisco.com/c/en/us/products/collate
mLOM C-Series ral/servers-unified-computing/ucs-c-series-rack-se
rvers/select-ucs-ucsx-accessories-eol.html
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 92
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Parameter Value
Weight
Weight with following options and no rail kit: 22.32 lbs (10.1 kg)
1 HDD, 1 CPU, 1 DIMM, and 1 1600 W power supply
Weight with following options and including rail kit: 32.38 lbs (14.7 kg)
1 HDD, 1 CPU, 1 DIMM, and 1 1600 W power supply
Weight with following options and no rail kit: 32.38 lbs (14.7 kg)
10 HDDs, 2 CPUs, 32 DIMMs, and 2 1600 W power supplies
Weight with following options and including rail kit: 42.43 lbs (19.3 kg)
10 HDDs, 2 CPUs, 32 DIMMs, and 2 1600 W power supplies
93 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Power Specifications
The server is available with the following types of power supplies:
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (V rms) 100 to 240
Maximum Allowable Input Voltage Range (V rms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 800 1050
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) 100 120 208 230
Nominal Input Current (A rms) 9.2 7.6 5.8 5.2
Maximum Input at Nominal Input Voltage (W) 889 889 1167 1154
Maximum Input at Nominal Input Voltage (VA) 916 916 1203 1190
Minimum Rated Efficiency (%)2 90 90 90 91
Minimum Rated Power Factor2 0.97 0.97 0.97 0.97
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12
Notes:
1. Maximum rated output is limited to 800W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 94
TECHNICAL SPECIFICATIONS
Parameter Specification
Input Connector Molex 42820
Input Voltage Range (V rms) -48
Maximum Allowable Input Voltage Range (V rms) -40 to -72
Frequency Range (Hz) NA
Maximum Allowable Frequency Range (Hz) NA
Maximum Rated Output (W) 1050
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) -48
Nominal Input Current (A rms) 24
Maximum Input at Nominal Input Voltage (W) 1154
Maximum Input at Nominal Input Voltage (VA) 1154
Minimum Rated Efficiency (%)1 91
Minimum Rated Power Factor1 NA
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 5
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
95 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (V rms) 200 to 240
Maximum Allowable Input Voltage Range (V rms) 180 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W) 1600
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) 100 120 208 230
Nominal Input Current (A rms) NA NA 8.8 7.9
Maximum Input at Nominal Input Voltage (W) NA NA 1778 1758
Maximum Input at Nominal Input Voltage (VA) NA NA 1833 1813
Minimum Rated Efficiency (%)1 NA NA 90 91
Minimum Rated Power Factor2 NA NA 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 12
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 96
TECHNICAL SPECIFICATIONS
Parameter Specification
Input Connector IEC320 C20
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 2300
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 13 11 12 10.8
Maximum Input at Nominal Input Voltage (W) 1338 1330 2490 2480
Maximum Input at Nominal Input Voltage (VA) 1351 1343 2515 2505
Minimum Rated Efficiency (%)2 92 92 93 93
Minimum Rated Power Factor2 0.99 0.99 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12
Notes:
1. Maximum rated output is limited to 1200W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Titanium certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
http://ucspowercalc.cisco.com
97 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Environmental Specifications
The environmental specifications for the C220 M6 server are listed in Table 36.
Parameter Minimum
Operating Temperature Dry bulb temperature of 10°C to 35°C (50°F to 95°F)
Maximum temperature change of 20°C (36°F) per hour
(a temperature change within a specified period of time and not
a rate of change)
Humidity condition: Uncontrolled, not to exceed 50% RH starting
condition
Derate the maximum temperature by 1°C (33.8°F) per every 305
meters of altitude above 900m
Extended Operating Temperature 5°C to 40°C (41°F to 104°F) with no direct sunlight
Humidity condition: Uncontrolled, not to exceed 50% RH starting
condition
Derate the maximum temperature by 1°C (33.8°F) per every 305
meters of altitude above 900m
Non-Operating Temperature Dry bulb temperature of -40°C to 65°C (-40°F to 149°F)
Operating Relative Humidity 10% to 90% and 28°C (82.4°F) maximum dew-point temperature,
non-condensing environment
Minimum to be higher (more moisture) of -12°C (10.4°F) dew
point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90% relative humidity
Non-Operating Relative Humidity 5% to 93% relative humidity, non-condensing, with a maximum
wet bulb temperature of 28°C across the 20°C to 40°C dry bulb
range.
Maximum Operating Duration Unlimited
Operating Altitude A maximum elevation of 3050 meters (10,006 ft)
Non-Operating Altitude An elevation of 0 to 12,000 meters (39,370 ft)
Sound Power level, Measure 5.5
A-weighted per ISO7779 LWAd (Bels)
Operation at 23°C (73°F)
Sound Pressure level, Measure 40
A-weighted per ISO7779 LpAm (dBA)
Operation at 23°C (73°F)
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 98
TECHNICAL SPECIFICATIONS
Table 37 Cisco UCS C220 M6 Extended Operating Temperature Hardware Configuration Limits
99 Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in Table 38.
Parameter Description
Regulatory Compliance Products should comply with CE Markings per directives
2014/30/EU and 2014/35/EU
Safety UL 60950-1 Second Edition
CAN/CSA-C22.2 No. 60950-1 Second Edition
EN 60950-1 Second Edition
IEC 60950-1 Second Edition
AS/NZS 60950-1
GB4943 2001
EMC - Emissions 47CFR Part 15 (CFR 47) Class A
AS/NZS CISPR32 Class A
CISPR32 Class A
EN55032 Class A
ICES003 Class A
VCCI Class A
EN61000-3-2
EN61000-3-3
KN32 Class A
CNS13438 Class A
EMC - Immunity EN55024
CISPR24
EN300386
KN35
Cisco UCS C220 M6 Rack Server (Small Form Factor Disk Drive Model) 100