6566L_VRV Catalogue_A4

WORLD’S LEADING AIR CONDITIONING


S TA N D R A D A M B I E N T C L I M AT E
C O M PA N Y F R O M J A PA N

NEW MINI VRV SERIES PROVIDING


PERFECT COMFORT FOR HOME

w w w. d a i k i n m e a . c o m
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin MEA. Daikin MEA has compiled the content of this
publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content
and the products and services presented therein. Specifications are subject to change without prior notice. Daikin MEA explicitly rejects any liability for any direct or indirect
damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin MEA.

P.O. Box 18674, Plot MO0426, JAFZA North, Jebel Ali Free Zone, Dubai, UAE | Tel: +971 (0) 4 815 9300 | Fax: +971 (0) 4 815 9311
E-mail: info@daikinmea.com Web: www.daikinmea.com Toll Free: 800-DAIKIN (324546)

MINIVRV | APRIL2022
6566L_VRV Catalogue_A4

INDEX
• ABOUT DAIKIN 04

• EXPLORING NEW RESEARCH & DEVELOPMENT FRONTIERS 05

• MINI VRV S 06

• A P P L I C AT I O N 08

• M A I N F E AT U R E S A N D O U T D O O R U N I T L I N E - U P 10

• RELIABILITY 11

• ENERGY EFFICIENCY 12

• LOW NOISE 13

• E A S Y I N S TA L L AT I O N 14

• DESIGN FLEXIBILITY 15

• C O N T E M P O R A RY 16

• U S E R C O M F O RT 17

• INDOOR UNIT LINE-UP 18

• INDIVIDUAL CONTROLLER 28

• M A D O K A A S S I S TA N T 30

• M O B I L E C O N N E C T I V I T Y & H O M E A U T O M AT I O N 31

• REIRI HOME 32

• CENTRALIZED CONTROLLER 36

• ITOUCH MANAGER 36

• H E A D E R PA C K 37

• DAIKIN TIGHTFIT JOINTS 38

• O U T D O O R U N I T S S P E C I F I C AT I O N S 40

• I N D O O R U N I T S S P E C I F I C AT I O N S 41
6566L_VRV Catalogue_A4

ABOUT DAIKIN EXPLORING NEW R&D FRONTIERS

At Daikin®, we are a leading innovator and provider of advanced, At Daikin, we are creating value
through innovative technologies. As a
high-quality air-conditioning solutions for residential applications.
global industry front-runner, we are
carrying out research and development
As World's leading air conditioning company, we are committed to delivering air-conditioning solutions that enhance the quality of life
on the world’s most advanced air
all around the World. Daikin Industries Ltd., a diverse multinational company active in air-conditioning, chemicals and oil hydraulics,
conditioning technology. Our strong R&D
was established in 1924. With headquarters in Osaka, Japan, our Daikin family has more than 67,000 members, working across
edge has helped us create futuristic products that
80 production base units and 208 consolidated subsidiaries worldwide. As the world's sole manufacturer that develops a long line of
enrich people’s lives.
products from refrigerants to air-conditioners, we advocate comfortable living on the strength of advanced technologies.

We are present in the USA, Europe and Russia, the Middle East, Africa, Asia, Oceania and Middle-South America. We aim to serve Formation of a three-division
our customers in each of these markets by providing optimal air-conditioning solutions. system of research, IT, and
development to support our superior
products. To create more advanced
functions and new value, we have
instituted specialized R&D divisions: the
‘Environmental Technology Research
Laboratory’ and the ‘Solution Product
Development Centre’.

DEVELOPMENT
Product Development Group

RESEARCH IT
Environment Technology Solution Product
Research Laboratory Development Centre

Environmental Technology Research The Solutions Product Development Centre: Integrating Air
Laboratory: Intensive Research on Conditioners with IT.
Environmentally Conscious, Energy
Saving Air Conditioning Technology.

04 05
6566L_VRV Catalogue_A4

MINI VRV S MINI VRV S

INTRODUCTION CONTEMPORARY
MINI VRV S is the ideal air conditioning system as it replaces multiple outdoor units Creative and modern design to fit your personal heaven.
with only one unit maintaining the picturesque view of the building. MINI VRV S is
ideally suited for residences as it offers a range of indoor units, which can be
connected with a centralized outdoor unit.

NEW LIFE STYLE


Redefining Home Air Conditioning
A complete solution that provides Cooling/Heating, Comfort,
Control and Convenience in one single system.

CARING
Creates a pleasant environment for you and
your loved ones.

CONCEALED
Hidden elegance to complement your beautifully
designed home interiors.

06 07
6566L_VRV Catalogue_A4

CENTRALIZED HOME AIR CONDITIONING


A P P L I C AT I O N A P P L I C AT I O N

CENTRALIZED HOME AIR CONDITIONING

In a conventional split air-conditioning system, a house requires same


number of outdoor units and indoor units. For example, a place with
four rooms will have four indoor units and four outdoor units.

An apartment or a house that does not have sufficient space will find difficult to accommodate numerous outdoor units. Even if
the outdoor units are somehow crowded together they will consume a lot of space, look cluttered and ruin the aesthetics of the
house.

MINI VRV S replaces all the outdoor units of the house with just one outdoor unit. A total of 19 indoor units can be connected to one
outdoor unit to create the space you have always desired. Also you have different styles of indoor units like duct type and wall
mounted type that can be connected with a single outdoor unit. Furthermore, actual piping length of up to120 meters coverage
of widespread spaces is ensured.

MINI VRV S is the ideal air-conditioning system as it replaces multiple outdoor units with only one unit maintaining the
picturesque view of the building. MINI VRV S ideally suited for small villas, houses or high-raised residences as well as
for offices, shops and gyms as it offers panoply of indoor units, which can be connected with only one outdoor unit.

OUTDOOR UNIT CAN BE INSTALLED ON A BALCONY


The compact, trunk-shaped outdoor unit can easily be installed on a balcony,
realizing complete system installation within each floor. This enables more
useful utilization of the space on the building rooftop.

OUTDOOR UNIT CAN BE INSTALLED ON MECHANICAL ROOM


MINI VRV S outdoor unit can achieve high external static pressure up to 40 Pa (for 6 & 8 HP),
ensuring the efficient heat dissipation and stable operation in case of using ducts or louvers

OUTDOOR UNIT CAN BE INSTALLED ON THE ROOF


Low height casing design of 870 mm for 6 & 8 HP models saves roof space by
up to 41% as compared to a standard two-fan Mini VRV series due to
possibility of stacked installation of two VRV outdoor units using special
Daikin Duplex Mounting Bracket (option)

Variety of installation options (in limited roof space, in mechanical room, in


balcony) makes MINI VRV S ideal product for small villas, houses or
high-raised residences as well as for offices, shops and gyms.

08 09
6566L_VRV Catalogue_A4

M A I N F E AT U R E S RELIABILITY

RELIABILITY USER COMFORT DESIGN FLEXIBILITY PCB BOARD PROTECTION*

ENERGY EFFICIENCY LOW NOISE CONTEMPORARY Refrigerant cooling technology ensures the stability of PCB temperature & improves reliability at high ambient temperatures. It is possible
to cool the inverter power module stability even at high ambient temperature. This helps to keep air-conditioning capacity and also
EASY INSTALLATION
ensures efficient and reliable operation. In addition to stable cooling, Refrigerant Cooling Circuit prevents PCB board from dust, water,
and small animal entering, making this design solution ideal for hot desert climate compared to traditional air-cooled PCB Boards.
OUTDOOR LINE-UP
6 models: Outdoor unit can be selected from six models to provide
the power that suits your needs. The trunk-shaped outdoor unit can be
neatly installed outside.

Capacity(HP)

Model Name Product Image 4 5 6 8 10 12

RXQ-ARV1
1 phase power supply

Side Discharge, Single Fan

RXMQ-ARV1
1 phase power supply

Side Discharge, Single Fan

RXMQ-ARY1 Wide Area Heat Exchanger is designed to ensure delivery of required capacity at any ambient
3 phase power supply conditions. Heat Exchanger Fins are covered with Blue Film which consists of corrosion resistance layer
Side Discharge, Single Fan covered with hydrophilic surface treatment coating to withstand harsh environment conditions.**

RXMQ-ARY1
3 phase power supply

Side Discharge, Double Fan


60
52CDB***
WIDE OPERATION TEMPERATURE RANGE 50
The versatile operation range of the MINI VRV S system works to reduce limitations on 40
Note
installation locations. The operation temperature range for cooling goes all the way
- 1 phase power supply
up to 52C*** due to the adoption of a high-pressure dome-type 30
- 3 phase power supply
compressor 20
SINGLE-PHASE POWER SUPPLY Note
* Applicable for bigger models (starting from 6 HP)
10
The 4, 5 & 6 HP Outdoor Units, as well as indoor units, operate on a single-phase power supply. This enables MINI VRV S ** In case units are located in coastal areas, addional coating will be required.
Contact your local distributor for more details about available options. 0
adaptation at residences where 3 phase power supply is not available.
*** Applicable for 6 & 8 HP Units; 10 & 12 HP units can operate up to 50 deg.C; 4 & 5 HP Units - up to 49 deg.C 0CDB
-10

10 11
6566L_VRV Catalogue_A4

ENERGY EFFICIENCY LOW NOISE

SMOOTH AIR INLET BELL MOUTH AND AERO SPIRAL FAN

With the bent Without the bent


Guides are added to the bell mouth intake to reduce blade edge blade edge
turbulence in the airflow generated by fan suction. The
Aero Spiral Fan features fan blades with bent blade
edges, further reducing turbulence.

Escaping eddies are sucked in by


the bent blade edges, reducing
overall turbulence

NIGHT-TIME QUIET OPERATION FUNCTION

Operation sound level selectable


Mode 1 Automatic mode
from 3 steps for the night mode
HIGH EFFICIENT COMPRESSOR TO ACHIEVE HIGH COP

Capacity %
One of the top features of MINI VRV S is its energy efficiency. It achieves high COP Peak in outdoor temperature
especially at part load. MODE 1 AUTOMATIC MODE 100

Set on the outdoor PCB. The time of maximum temperature is 8 hrs 8 hrs
(Intail setting) (Intail setting)
memorized. The low operating mode will become active 8 50

Load %
COMPRESSOR EQUIPPED WITH RELUCTANCE DC MOTOR hours*1 after the peak temperature in the daytime, and operation
will return to normal 10 hours*2 after that. The operation sound 0 Night mode
MINI VRV S Outdoor Units are equipped with the Reluctance DC 50

Operation Sound dB(A)


level for the night mode can be selected from 47 dB(A) (Step 1), Step 1 max. - 3 dB(A)
motor for the compressor. The Reluctance DC motor uses 2 ( 4 HP/11.2 kW)
Step 1: 47 dB(A)
44 dB(A) (Step 2), and 41 dB(A) (Step 3). 47
different types of torque, neodymium magnet*1 and reluctance Step 2 max. - 6 dB(A)
Step 2: 44 dB(A)
( 4 HP/11.2 kW)
torque*2. This motor can save energy because it generates more 44

power with a smaller electric power than an AC or conventional


MODE 2 MANUAL MODE Step 3 max. - 9 dB(A)
( 4 HP/11.2 kW)
Step 3: 41 dB(A)
41
DC motor. Night mode Starts Night mode ends
Starting time and ending time can be input. (An external control 8:00 12:00 16:00 20:00 00:00 4:00 8:00
*1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. adaptor for outdoor unit, DTA104A61 or DTA104A62, and a
*2 The torque created by the change in power between the iron and magnet parts.
locally obtained timer are necessary.)
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory Note: • This function is available in setting at site.
using Daikin products. MODE 3 COMBINED MODE
• The relationship of outdoor temperature (load) and

Combinations of modes 1 and 2 can be used time shown in the graph is just an example.

depending on your needs. *The capacity reduction rate differs depending on the
*1. Initial setting. Can be selected from 6, 8 and 10 hours. operation sound level step selected.
*2. Initial setting. Can be selected from 8, 9 and 10 hours.

12 13
6566L_VRV Catalogue_A4

E A S Y I N S TA L L AT I O N DESIGN FLEXIBILITY

BRAZING FREE INSTALLATION

Flare connection based header pack and Daikin


TightFit Joints eliminate the need for brazing
resulting in quick, safe & quality installation.

Please refer to pages 39-40 for


HEADER PACK DAIKIN TIGHTFIT JOINTS more details or watch the video:

PIPING LENGTH
MINI VRV S series offers broad design flexibility with long refrigerant piping lengths and multiple indoor
unit combinations, which provides generous freedom for home design both inside and outside.
LONG PIPING
AS MANY AS 19 INDOOR UNITS CAN BE DESIGN POSSIBLE*
AUTOMATIC REFRIGERANT CHARGE FUNCTION AUTOMATIC TEST OPERATION CONNECTED TO A SINGLE OUTDOOR UNIT The MINI VRV S provides a long piping length
Multiple indoor unit combinations are possible. As many as 19 possibility of 120 m, with a total piping length of
Contribute to optimized operation efficiency, Simply press the test operation button, and the unit 300 m. If the outdoor unit is installed above indoor
indoor units can be connected to a single outdoor unit, making
higher quality and easier installation performs an automatic system check, including wiring, units, the level difference can be up to a maximum of
the MINI VRV S remarkably versatile system.
shutoff valves, and sensors. The results are returned 50 m. These generous allowances facilitate an extensive
variety of system designs.
automatically after the check finishes.
Optimized operation efficiency
The automatic refrigerant charge function automatically
Total pipe length: 300mtr
determines the optimal amount of refrigerant to be Optimised Operation
1 2 3 4

charged. This function prevents a capacity shortage or


Max 40mtr
energy loss due to excessive or insufficient refrigerant. Cooling capacity
Efficiency Max 120mtr
5 6 7 8 9 Max 50mtr
Actual pipe length
Higher quality and easier installation. Level
difference
Max 15mtr
The automatic refrigerant charge function automates the charging of the Insufficient
refrigerant charge
Excessive
refrigerant charge Level
difference
proper refrigerant amount and the closing of shut-off valves with just one
press of the switch after pre-charging. simplified installation eliminates Optimal refrigerant
amount
Refrigerant charge
amount
MAX. 19 UNITS MAX. 19 UNITS
excessive and insufficient refrigerant charge amounts due to calculation
mistakes, leading to higher installation quality. • Max. 13 indoor units for an 8 HP installation • Max. 6 indoor units for a 4 HP installation
• Max. 16 indoor units for a 10 HP installation • Max. 8 indoor units for a 5 HP installation
• Max. 19 indoor units for a 12 HP installation • Max. 9 indoor units for a 6 HP installation
EASY TO HANDLE
TOTAL PIPING LENGTH MAX. 300 M*
In addition, low height makes the center of gravity of the product positioned lower,
leading to easier handling and easier delivery without blocking the workers' view. • The level difference between outdoor and indoor unit is 50 m
Less than 115 kg for 4, 5, 6, 8 HP Units, which can be carried by two people • Maximum piping length between the indoor unit and the first branch is 40 m.

Note:
* Applicable for the bigger units with the capacity 6 HP and above. Consult technical literature for the details

14 15
6566L_VRV Catalogue_A4

CONTEMPORARY USER COMFORT

CENTRALIZED AIR CONDITIONING

MINI VRV S offers centralized Lifestyle Air Conditioning solutions wherein one Outdoor unit can be connected
with multiple Indoor units. This system has the flexibility of connecting different types of Indoor units in the same
circuit. The suitable Indoor unit that blends with interiors and fulfill cooling requirements can be selected.

CONCEALED & SLEEK IDU DESIGN

 NEW LIFE STYLE


Technology meets Design

PRECISE TEMPERATURE CONTROL


Temp.

The inverter technology provides very close tolerance of the room


temperature in the range of +-0.5 degrees Celcius compared
Set
temp.

to a conventional system where it is as high as +- 2 degree


HIDE AND SLEEK Time

Celcius. This reduces temperature fluctuation resulting in During cooling operation


Non-Inverter type
Inverter type

The units are compact and slim enough to fit into any false ceiling, giving you more space and flexibility to better human comfort. Starts

create the perfect home you desire. Now, function and aesthetics can live in beautiful harmony.

NIGHT-TIME QUIET OPERATION


200 mm
Quietness is an important feature of the MINI VRV S system as it provides luxurious comfort. To reduce noise and
realize comfortable operation; The latest technologies and features are applied to the indoor units as well as
outdoor unit.

16 17
6566L_VRV Catalogue_A4

INDOOR UNIT LINE-UP VRV INDOOR UNITS

A variety of VRV indoor units are enabled in one system, opening the door to stylish and quiet indoor units.
WALL MOUNTED
Type Model Name Capacity Range HP 0.6
FXAQ20ARVM / FXAQ25ARVM
Capacity Index 15
FXAQ32ARVM / FXAQ40ARVM
Wall Mounted FXAQ-ARVM
FXAQ50ARVM / FXAQ63ARVM

Ceiling Mounted
FXFSQ-ARV1
Cassette Round
Flow NEW Stylish flat panel design • Stylish flat panel design creates a graceful harmony that enhances any
interior space.
Slim Ceiling FXDQ-PDVM harmonized with your
Mounted • Flat panels can be cleaned with only a single pass of cloth across their
Duct
interior decor smooth surface.
FXDQ-NDVM

• Vertical auto-swing realize the efficiency of air distribution. The louver closes
automatically when the unit stops.
Low Static
Concealed Ceiling FXMQ-ARV1 Low operation sound level dB(A)
Duct

High Static FXAQ-ARVM 20 25 32 40 50 63


FXMQ-PBV1
Concealed Ceiling
Duct NEW Sound Level
(H/L) / / / / / /
Medium Static
FXSQ-A2VEB
Concealed Ceiling
Duct • Drain pan and air filter can be kept clean by mould-proof
polystyrene
Wall Mounted Type Ceiling Mounted Cassette Round Flow
• Five steps of discharge angle can be set by remote
FXAQ-ARVM FXFSQ-ARV1
Stylish flat panel design controller.
Individual flap control allows flexibility
harmonized with your interior to suit every room layout without • Discharge angel is automatically set at the same angle as
decor changing the location of the interior
decor the previous operation when restarting. (Initial setting:
10° for cooling.)

Slim Ceiling Mounted Duct Concealed Ceiling Mounted Duct


FXDQ-PDVM Flexible installation
FXMQ-PBV1

FXMQ-ARV1 • Drain pipe can be fitted to it from either left or right sides.
FXDQ-NDVM
FXSQ-A2VEB • Drain pump kit is available as an optional accessory, which
lifts the drain 1,000mm from the bottom of the unit.
Slim design, quiet and static Variety of the units with different
pressure switching external static pressure allow flexible
& concealed installation

18 19
6566L_VRV Catalogue_A4

VRV INDOOR UNITS Daikin VRV X Catalogue_India


VRV INDOOR UNITS
*1. Applicable when wired remote controller BRC1E63 & BRC1H* is used.
INDOOR UNIT LINE-UP
CEILING MOUNTED CASSETTE ROUND FLOW CIRCULATION AIRFLOW *2. Not applicable when using individual airflow direction control.
*3. Applicable when wired remote cont
*1. Applicable when wired remote controller BRC1E62 is used.
*2
FXFSQ25ARV1 / FXFSQ32ARV1 / FXFSQ40ARV1 CIRCULATION AIRFLOW COOLS THE ENTIRE ROOM TO DELIVER COMFORT THAT NEVER FEELS COLD.
FXFSQ50ARV1 / FXFSQ63A RV1/ FXFSQ80ARV1
FXFSQ100ARV1 / FXFSQ125ARV1 / FXFSQ140ARV1 Hot
outdoor air

blowing air directly on people


360 ° airflow improves temperature
distribution and offers a comfortable Cool air moves down
along the walls and to
Comfort without cold air
hot air near windows and walls
every corner of the room
living environment

CIRCULATION AIRFLOW INDIVIDUAL AIRFLOW

COMFORT TO THE ENTIRE ROOM WITH EVEN TEMPERATURES AND NO COLD AIR POCKETS AT FLOOR LEVEL
30.0
4-way cassette (Swing) 29.0
28.0 Room size:
27.0 Width 7.5m x depth 7.5m x
. Blows horizontally 26.0 height 2.6m
25.0 Indoor unit capacity:71 class
24.0
23.0 Outdoor air temperature:35
22.0
. Strikes the wall 21.0 high / swing
20.0

are cold while areas


around walls are hot.

Circulation Airflow (2-way horizontal + 4-way swing) Approx. %5 energy *3


. Reaches every corner of the room The illustration shows typical air flow. savings by reducing
Effectiveness may differ according to room uneven temperatures
conditions, room size, and distance to walls
The illustration shows typical airflow.
*3.Calculated under the following
comparison conditions:
When the average temperature at a
height of 0.6
reaches set temperature. (26oC)
DIRECT AIRFLOW Full comfort is
provided with no
cold feet.
Drain pump is equipped as a standard
accessory with an 850 mm lift. CONFIGURATIONS OF CIRCULATION AIRFLOW

Operation
When the target
(at start)
850 mm temperature is reached,
normal operation
(all-round Flow) begins.

Optimal air direction Swing (narrow)


by “Auto” Cools areas around Cools entire room Cools areas around Cools entire room Note: Results may vary depending on
walls using using 4-way equipment a, room size
walls using using 4-way and distance from indoor unit to walls.
2-way horizontal ow swing ow 2-way horizontal ow swing ow

20 21
26
6566L_VRV Catalogue_A4

VRV INDOOR UNITS VRV INDOOR UNITS

THREE TECHNOLOGIES THAT ACHIEVED CIRCULATION AIRFLOW Comfortable air conditioning for all *. Applicable when wired remote controller BRC and BRCH is used.

Flow-out is straight, horizontally, and strong, so the air travels far and even reaches the wall from which it falls to the floor.
room layouts and conditions Easy setting is possible with a wired remote controller.

This approach and technology makes circulation airflow possible. Airflow direction can be individually
There are
adjusted for each air discharge outlet to identification -
USE OF NEW WIDE FLAPS (STRAIGHT) marks
deliver optimal air distribution near the air
outlets
Compared to conventional models, the new Conventional flap*4 Conventional flap*4 Remote
controller screen
wide flap increase the straightness of the airflow,
so coverage is approximately doubled. Position 0
Approx (Fixed airflow to
doubled
highest position)

*4. FXFQ-S model Individual airflow settings


NEW WIDE FLAP CONSTRUCTION › No individual setting (auto airflow)
INHIBITS CEILING DIRT AND GRIME › Position 0
› Position 1
by tapering both flap ends, the airflow that causes No individual › Position 2
dirty ceilings is directed downward. setting › Position 3
(Auto airflow) › Position 4 (lowest point)
› Swing
OPTIMIZING AIRFLOW ANGLE (HORIZONTALLY) Swing Position 4 Individual settings are possible,--- as stated above.
(Up/Down) (Fixed air flow to the
Even with the flap raised, a sufficient route in maintained lowest position)
to realize more horizontal airflow angle.
CONVENTIONAL FLAP *4 *4.FXFQ-S model NEW WIDE FLAP
20° WHEN INDIVIDUAL AIRFLOW IS SELECTED, AIRFLOW DIRECTION CAN BE ADJUSTEDTO ROOM LAYOUT.
horizontal
flow

°30 air direction °20 air direction

When set to 20° the A more horizontal 20°


Even at °20
Cannot blow more airflow route get narrow the realized
than 30° horizontal. maintained.

2 Increased velocity in -2way flow (Strongly)


Velocity increased by making-
- 2 way flow,Powerful airflow was realized.

ALL-ROUND FLOW TWO-WAY FLOW

Velocity
*5
10%
increase

*5

*5.Other 2

22 23
27
6566L_VRV Catalogue_A4

VRV INDOOR UNITS VRV INDOOR UNITS


su rear
c ti
on

SLIM CEILING MOUNTED DUCT LOW STATIC PRESSURE CEILING MOUNTED DUCT TYPE
outb
low

Slim design, quietness and FXMQ40ARV1 / FXMQ50ARV1 /


static pressure switching Bottom
FXMQ63ARV1 / FXMQ80ARV1 /
FXMQ100ARV1

FXDQ20PDVM / FXDQ25PDVM / FXDQ40NDVM /FXDQ50NDVM /


FXDQ32PDVM FXDQ63NDVM Middle static pressure allows for High airflow rate
• Only 700mm in width and 23kg in weight, this model is • Only 200mm in height, this model can be installed in
flexible duct design Airflow rate is optimized to meet broader spectrum of
suitable for installation in limited spaces like drop-ceilings rooms with as little as 240mm depth between the drop airflow requirements.
• AC fan motor is installed to suit applications where
in hotel ceiling and ceiling slab
external static pressure is required at nominal capacity

30Pa-50Pa for FXMQ40ARV1


Low operation sound level* (db(A))
30Pa-60Pa for FXMQ100ARV1
FXMQ-AR
All models are only 300mm in height, an improvement over
Sound Level / / / / /
the 390mm height of conventional models
(H/L)
*Operation at 50 Hz

Drain pump is equipped as standard


* 1,100 mm in width for the FXDQ63NDVM model
accessory with 700mm lift Improved ease of maintenance
The drain pan can be detached for easy cleaning.
An antibacterial treatment that uses silver ions has been applied
to the drain pan, preventing the growth of slime, mould
700 mm and bacteria that cause blockages and odours.

Ceiling

*To be obtained locally

• Control of the airflow rate has been improved from 2-step • External static pressure selectable by remote controller
to 3-step control switching make this indoor unit a very comfortable and
flexible model.
Low operation sound level dB(A) 10Pa-30Pa/factory set: 10Pa for FXDQ-PDVM models.
15Pa-44Pa/factory set: 15Pa for FXDQ-NDVM models.
FXDQ
PDVM/
NDVM FXDQ - NDVM models are available
Sound Level
(HH/H/L) // // // // with a drain pump as a standard accessory

• The values of operation sound level represent those for


rear suction operation. Sound level values for bottom-suction
- operation
can be obtained by adding 5 dB(A).Values are based on the following
conditions: FXDQ-PDVM: external static pressure of 10Pa; FXDQ-NDVM:
external static pressure of 15Pa.

24 25
6566L_VRV Catalogue_A4

VRV INDOOR UNITS VRV INDOOR UNITS

MEDIUM STATIC CONCEALED CEILING DUCT High Static Concealed Ceiling Duct
FXSQ15A2VEB / FXSQ20A2VEB / FXSQ25A2VEB FXMQ40PBV1 / FXMQ50PBV1 /
FXSQ32A2VEB / FXSQ40A2VEB / FXSQ50A2VEB outblow
FXMQ63PBV1 / FXMQ80PBV1 /
FXSQ63A2VEB / FXSQ80A2VEB / FXSQ100A2VEB rear FXMQ100PBV1 / FXMQ125PBV1 /
suction

FXSQ125A2VEB / FXSQ140A2VEB bottom


suction FXMQ140PBV1
FXSQ-A

Slimmest yet most powerful medium Middle and high static


static pressure unit on the market pressure allows for flexible
duct design
• Slimmest unit in class, only 245mm (300mm built-in height) and • A DC fan motor increases the external static pressure
therefore narrow ceiling voids are no longer a challenge Standard built-in drain pump with 625mm lift capacity range to include middle to high static pressures,
increases flexibility and installation speed increasing design flexibility
245 mm
30Pa-160Pa for FXMQ40PBV1
50Pa-200Pa for FXMQ50-125PBV1
625 mm
50Pa-140Pa for FXMQ140PBV1
• Quiet operation: down to 25dBA sound pressure level
• Medium external static pressure up to 150Pa facilitates using All models are only 300mm in height, an improvement over
flexible ducts of varying lengths the 390mm height of conventional models. The weight of
• Possibility to change ESP via wired remote control allows the FXMQ40PBV1 has been reduced from 44kg to 28kg.
optimisation of the supply air volume Improved ease of installation
• Discretely concealed in the wall: only the suction and discharge
Airflow rate can be controlled using a remote controller
grilles are visible ////////////////////////////////////////// ////////////////////////////////////////// ////////////////////////////////////////// during test operations. With the conventional model,
• 15 class unit especially developed for small or well-insulated Drain pump is equipped as standard the airflow rate was controlled from the PC board.
700 mm
rooms, such as hotel bedrooms, small offices, etc. It is automatically adjusted to the range between
accessory with 700mm lift approximately ±10% of the rated HH tap airflow
• Multi zoning kit allows multiple individually-controlled climate
Ceiling for FXMQ40-125PBV1.
zones to be served by one indoor unit
• Optional fresh air intake For free use into a false For connecting onto a For direct connection to
ceiling suction canvas Daikin panel Control of the airflow rate has been improved from 2-step to
• Flexible installation: air suction direction can be altered from rear (not supplied by Daikin) (via EKBYBSD kit)
to bottom suction and choice between free use or connection to 3-step control.
optional suction grilles Improved ease of maintenance
External static pressure (Pa) Low operation sound level dB(A) The drain pan can be detached for easy cleaning.
An antibacterial treatment that uses silver ions has been
applied to the drain pan, preventing the growth of slime,
AUTOMATIC AIRFLOW ADJUSTMENT FUNCTION Fan characteristi c
curves
mould and bacteria that cause blockages and odors.

Automatically selects the most appropriate fan curve to achieve the units’ Sound Level 37/37/35 41/39/37 42/40/38 43/41/39 // //
nominal air flow within ±% (HH/H/L)

Why? Energy-efficient
After installation the real ducting will frequently differ from the initially calculated air flow resistance Duct r esistance
curves
matic adjustment ) AUTOMATIC AIRFLOW ADJUSTMENT FUNCTION › The adopted DC fan motor is much more efficient than
* the real air flow may be much lower or higher than nominal , leading to a lack of capacity or - the conventional AC motor, yielding an approximate 20%
- decrease in energy consumption (FXMQ125PBV1).
uncomfortable air temperature Automatic Airflow Adjustment function will adapt the unit’s fan ± /min)
Automatically selects the most appropriate fan curve to achieve the units’
speed to any ducting automatically (10 or more fan curves are nominal air flow within ±10%
available on every model),making installation much faster

26 27
6566L_VRV Catalogue_A4

INDIVIDUAL CONTROLLER INDIVIDUAL CONTROLLER

INDIVIDUAL CONTROL SYSTEMS INDIVIDUAL CONTROL SYSTEMS FOR VRV INDOOR UNITS
BRC1H52W / BRC1H52S / BRC1H52K Navigation remote controller (Wired remote controller) (Optional)

Madoka wired remote controller for Sky Air and VRV Clear display
• Dot matrix display
A complete redesigned controller focussed A combination of fine dots enables various
to enhance user experience icons. A large text display is easy to see.

• Backlight display
• Sleek and elegant design • Three colors to match any interior
BRC1E63
Backlight display helps to operate in dark rooms.
• Intuitive touch-button control • Compact, measures only 85 x 85 mm
• Two display options: standard and detailed • Real-time clock with auto-update to
Simple operation
• Direct access to basic functions daylight saving time
BRC1H52W (on/off, set point, mode, target values, fan • Equipped with a buzzer • Large buttons and arrow keys
speed, louvers, filter icon & reset (4), error & code) • Guide on display

Hotel application features

Wireless remote control (optional)


• Energy saving through key card, window contact integration and set

BRC1H52S point limitation (BRP7A*)


• Flexible setback function ensures room temperature remains within A compact signal receiver unit (separate type)

comfortable limits to ensure guest comfort to be mounted into wall or ceiling

Key card and Adaptor


(BRPA*) Key card (field supply)
BRC1H52K
window contact
integration
Window contact
(field supply)

BRCH/W

MADOKA ASSISTANT: ADVANCED SETTINGS CAN BE EASILY DONE VIA YOUR SMARTPHONE

A range of energy-saving functions Temperature range restriction means no


that can be selected individually Other functions excessive heating/cooling
• Temperature range restriction • Up to three independent schedules can Save on energy by constraining the lower
beprogrammed, allowing you to switch easily
• Setback function temperature limit in cooling and upper temperature
between them throughout the year (e.g.
• Presence and floor sensor setting summer/winter/ mid-season) limit in heating mode
(available on the Round Flow and Fully Flat • Possibility to individually restrict menu functions
Cassettes)
• Set temperature auto reset
• Off timer

28 29
6566L_VRV Catalogue_A4

M A D O K A A S S I S TA N T MOBILE CONNECTIVITY

Monitoring

Access within
the premises Advanced
Access control
anywhere outside

SIMPLIFIES THE ADVANCED SETTINGS SUCH AS SCHEDULE OR SET POINT LIMITATION

• Visual interface simplifies advanced settings such as schedule setting,


energy saving activation, setting restrictions, etc.

• Easy and quick commissioning

• Featuring Bluetooth® low energy technology

Easy setting of schedules Advanced user settings Installer settings Field settings

30 31
6566L_VRV Catalogue_A4

REIRI HOME REIRI HOME

Smart
HOME | LIVING
Enhance comfort and convenience for the
user, offering complete control of air conditioning
systems & other smart devices remotely through
mobile app access.

Possibility to connect in one control system:


- up to 64 Indoor Units
- up to 10 Outdoor Units
- up to 80 Z-wave devices

ALSO COMPATIBLE :

ReiriHome ReiriHome connect all All connected accessible anytime


ReiriHome ReirHome Lite smart devices and allow from anywhere through mobile
DCPH01 DCPH02 them communicate with phone
each other

FLEXIBLE INTEGRATION CONTROL & MANAGE Interlock devices for different


Control, monitor, and manage automation and action for
with wireless residential smart devices All device in one platform all devices on one screen different requirement

Features true to product performance


Actual control interface may vary due to interface design enhancement

32 33
6566L_VRV Catalogue_A4

REIRI HOME REIRI HOME

FEATURES

Convenience & Lifestyle • Complete control of all


• Energy Management connected devices
ACCESS WITHIN THE PREMISES The complete smart home solution for every
homeowner, with integration capabilities to • IAQ Management • Easy installation (Plug & Play)
Daikin Reiri Home Control Series provides the ability allow ease and convenience of control for • Home Security Solution and configuration
of centralized control for Daikin VRV air conditioners almost every smart device.
• Google Home enabled • Push Notification
throughout the home with a smartphone. Homeowners
can control all of the core control functions in Daikin air Modbus Devices • Mobile Control of Airconditioning Units • Compliant with Cyber-security
conditioning system effortlessly from one room to another. • User-friendly App Interface certification (EN303645)
Reiri

ACCESS ANYWHERE OUTSIDE IAQ Sensor Smart Meter


Reiri Adaptor
DCPA01
ReirHome
With Daikin Reiri Home Control Series, the home DCPH01
temperature can be controlled from anywhere, and
homeowners can always return from work or vacation to a
comfortable cooling home. This also takes the pressure off
homeowners on forgetting to switch off the air conditioners
when away.

ADVANCED CONTROL
Wi-Fi Router
Daikin Reiri Home Control Series communicates with all
of Daikin VRV air conditioners, allowing homeowners to
access the core control functions on a smartphone, including
temperature set points, operation mode, fan speed, airflow
direction and error notification. App Access Compatible with:

IP Camera

WAGO I/O System

Up to 5 nodes

MONITORING Smart Home devices

*Additional Interface
Homeowners can enjoy peace of mind and the Adaptors may be required
Smoke
convenience of monitoring air conditioners with Roller Curtain Detector Smart Plug Light
Lighting Pump Fan Sensor
Daikin Reiri Home Control Series from a smartphone.
Door Lock

Motion
Flood Sensor Door Sensor Sensor

34 35
6566L_VRV Catalogue_A4

ITOUCH MANAGER H E A D E R PA C K

ADVANCED CONTROL SYSTEMS FOR VRV INDOOR UNITS The Innovative Refrigerant Piping of next generation
Daikin innovated the Next Generation of Quality and Efficiency for VRV Installation. It offers differentiated soulutions
in installation. It ensures quality installation with a reduction of site work.

One-touch selection enables flexible control of equipment in a building. Advantage


• Installation time saving: Up to 1/3 of the conventional method
• Easy to Install: Hanging points available
• Safety: Consists of flaring method, no brazing required
Various types of equipment
• Quality Installation: Elimination of complex processes, enhancing
in a building can be
quality Installation
controlled by a single
controller.
Quick, flare
DCMA nut connection

INDIVIDUAL AIR-CONDITIONING CONTROL


The flexible control achieved by the VRV system precisely
meets different air conditioning needs in each room (e.g. No need of
offices, conference rooms, hotel rooms). brazing
Automatic Airflow Adjustment function
Easy,
soft copper
tube piping

LIGHTING CONTROL
Compact design to fit into narrow attic space
DALI-compatible LED lighting systems can be controlled and
-
monitored. Lighting control is enhanced through an interlock
Outdoor Unit Side Connection Indoor Unit Side Connection
function with air conditioners and other functions. Indoor
Unit Dimensions
Liquid Pipe Gas Pipe Number of Ports Large (Connection Diameter) Small (Connection Diameter) Total (mm)
HP (VRV HEADER PACK Diameter Diameter Connection Connection
Capacity
System) Model (mm) (mm) Type Total Small Type H W D
Large Liquid (mm) Gas (mm) Liquid (mm) Gas (mm) Index
6 BHF6RHP6Z 9.5 15.9 Flare 4 1 3 9.5 15.9 6.4 12.7 Flare <150 135 559 143
6 BHF6ARHP6Z 9.5 15.9 Flare 6 2 4 9.5 15.9 6.4 12.7 Flare <150 135 623 143
6,8 BHF8RHP6Z 9.5 19.1 DGT 6 3 3 9.5 15.9 6.4 12.7 Flare <200 135 623 143
10 BHF10RHP6Z 9.5 22.2 DGT 6 3 3 9.5 15.9 6.4 12.7 Flare <290 135 623 143
12,14,16 BHF16RHP6Z 12.7 28.6 DGT 6 3 3 9.5 15.9 6.4 12.7 Flare <420 135 623 143

Top view
AIR-CONDITIONING CONTROL FOR LARGE SPACES
BHF6RHP6Z BHF6ARHP6Z, BHF8/10/16RHP6Z
BUILDING EQUIPMENT CONTROL
Air handling units can also be controlled. Large spaces, 517
Suspension bolt Pitch
580
Suspension bolt Pitch
-
such as entrance halls and shopping malls, can be easily -
Various types of equipment other than air conditioners,
controlled to ensure comfort. including ventilation, fans, and pumps, can also be

Suspension bolt Pitch

Suspension bolt Pitch


controlled.

178

178
D

D
Pump Fan W W
36 37
6566L_VRV Catalogue_A4

DAIKIN TIGHTFIT JOINTS DAIKIN TIGHTFIT JOINTS

TRUSTY FULL LINE-UP

No copper Oxide • One-stop-shopping . To conduct No Hot Work piping installation, all necessary parts are supplied
including site inspection accessories
• No brazing soot and scale pipe inner surface

• Clean shiny copper pipes after installation Standard Joint Asymmetrical


• Prevent early compressor failure, no soot in pipes

SAFETY

No hot works – just squeeze!


• No brazing requires, abolish fire hazard

• To avoid the risk to handle high pressure, flammable gases

Size Model name Size Model name


EASY Low torque Ø 6.35 SDGTB06 Ø 9.5-6.4 SDGTB0906
Ø 9.52 SDGTB09 Ø12.7-9.52 SDGTB1209
50 Ø 12.7 SDGTB12
• Low torque allows easy work on a scaffolding Ø 15.88-12.7 SDGTB1512
Ø 15.88 SDGTB15 Ø 19.05-15.88 SDGTB1915
• No need for heavy, expensive special tools 40

30% less Ø 19.05 SDGTB19 Ø 22.22-19.05 SDGTB2219


• No need for special technicians for brazing 30 Ø 22.22 Ø 25.4-22.22
SDGTB22 SDGTB2522
45Nm Ø 28.58 SDGTB28 Ø 28.58-25.4 SDGTB2825
20
30Nm Ø 34.92 BDGTA34 Ø 34.92-28.58 SDGTB3428
10 Ø 41.28 BDGTA41

0
Current model New model
Type:SDGTB19
DIMENTIONS & WEIGHT
SAVING

• No specific permit, no specialized personnel


Standard Joint
Size L (mm) Weight (g)
• Time saving with a short schedule installation project
Ø 6.35 50.4 44

• Simple installation process Ø 9.52 55.0 80


Ø 12.7 59.0 120
• Cost & time saving with less administration work Ø15.88 74.0 207
Ø 19.05 76.8 273
Hot work permit and safety fire watcher Ø 22.22 83.4 391
Ø 28.58 88.0 515
Ø 34.92 101.5 686 L L
Ø 41.28 103.5 881 Ø 6.35 - Ø 28.58 Ø 34.93 - Ø 41.28

38 39
6566L_VRV Catalogue_A4

O U T D O O R U N I T S S P E C I F I C AT I O N S I N D O O R U N I T S S P E C I F I C AT I O N S

Wall Mounted

4HP and 5 HP 6HP and 8HP 10HP and 12HP MODEL FXAQ20ARVM FXAQ25ARVM FXAQ32ARVM FXAQ40ARVM FXAQ50ARVM FXAQ63ARVM

Power supply 1-phase, 220V / 240V, 50/60 Hz


Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
kW 2.2 2.8 3.6 4.5 5.6 7.1
Heating capacity Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
kW 2.5 3.2 4.0 4.3 6.3 8.0
Casing White (N9.5)
Airflow rate (H/L) m3/min 7.5/4.5 9/5 11/5.5 13/9 15/12 19/14
cfm 265/159 318/177 388/194 459/318 530/424 671/494
Sound level (H/L) dB(A) 35/31 36/31 38/31 39/34 42/37 47/41
Dimensions (H×W×D) mm 298X929X258 298X929X258 298X929X258 298X929X258 298X929X258 298X929X258
Machine weight kg 13.0 13.0 13.0 13.0 13.0 13.0
Piping Liquid (Flare) mm 6.4 6.4 6.4 6.4 6.4 9.5
connections Gas (Flare) mm 12.7 12.7 12.7 12.7 12.7 15.9
Drain mm VP13 (External Dia. 18/Internal Dia. 13)

Model RXQ4ARV1 RXQ5ARV1 RXMQ6ARV1 RXMQ8ARY1 RXMQ10ARY1 RXMQ12ARY1

Power Supply
Cooling Capacity (1) KW 11.20
1 PHASE, 50Hz, 220-240 V
14.00 16.00 22.40
3 Phase, 50 Hz, 380-415V
28.00 33.50
Ceiling Mounted Cassette Round Flow
Cooling Capacity Btu/h 38,200 47,800 54,600 76,400 95,500 114,300
INPUT Power KW 2.88 3.93 4.1 6.61 8.50 10.8
EER - 3.89 3.56 3.90 3.39 3.29 3.10
Dimensions(H*W*D) 990 x 940 x 320 870x1100x460 1627 x 940 x 450 MODEL FXFSQ25ARV1 FXFSQ32ARV1 FXFSQ40ARV1 FXFSQ50ARV1 FXFSQ63ARV1 FXFSQ80ARV1 FXFSQ100ARV1 FXFSQ125ARV1 FXFSQ140ARV1

% 50-130 Power supply 1- phase, 220-240V, 60 /50/60 Hz


Allowed Indoor Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 54,600Z
Nom 100 125 150 200 250 300 kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 16.0
Capacity Index Min 50 62.5 75 100 325 390 Heating capacity Btu/h 10,900 13,600 17,100 21,500 27,300 34,100 42,700 54,600 54,600
Connection Max 130 162.5 195 260 125 150 kW 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16 16
Min 0°C 0°C 0°C 0°C 0°C 0°C Casing Galvanised steel plate
Operation Range Airflow rate (H/M/L) m3/min 13/11.5/10 17/12.5/11 23/19/11 23.5/20/13.5 24.5/20.5/15 33.5/27/21 34.5/28.5/23 35.5/29.5/23
Max 49°C 49°C 52°C 52°C 50°C 50°C 459/406/353 600/441/388 812/671/388 830/706/477 865/724/530 1183/953/741 1218/1006/812 1253/1041/812
cfm
Type R410A Sound level (H/M/L) dB(A) 30/28.5/27 35/29/27 38/34.5/27 388/34.5/27 39/36/31 44/38/33 45/39.5/35 46/40.5/35
Refrigerant
Amount Kg 2.9 3.4 4.2 5.4 7 8
Dimensions mm 256x840x840 298x840x840
Pipe Diameter mm Φ 9.5 Φ 12.7
Machine weight kg 19 22 25 26
Connection Piping Liquid (Flare) mm 6.4 9.5
Type FLARE BRAZING
Liquid connections Gas (Flare) mm 12.7 15.9
Pipe Drain mm Dia. 26(hole)
Diameter mm Φ 15.9 Φ 19.1 Φ 22.2 Φ 25.4
Standard Panel Model BYCQ125EAF9(Fresh White)
Connection
Type FLARE BRAZING (Optional) Dimensions (HxWxD) mm 50x950x950
Liquid Weight kg 5.5
Machine kg 72 79 97 115 165 170 * Optional PM2.5 Filter is available upon request
Weight
Packed kg 80 87 110 128 185 190
Sound Level (2) dBA 52 53 52 59 59 60 Note:
1) Specifications are based on the following conditions:
2) Cooling: Indoor temp 27CDB, 19CWB / Outdoor temp: 35CDB, Equivalent piping length: 7.5m / Level difference: 0m
Notes: 3) The Capacity of indoor unit is only for reference. The actual capacity of indoor unit is based on the total capacity index .(See Engineering Data Book for details.)
(1) Indoor temp.: 27°CDB, 19°CWB / Outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. 4) Sound level: Anechoic chamber conversion value measured at a point 1.5m downward from the unit center. During actual operation, these values usually are somewhat higher as a resultof ambient conditions.
(2) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.

40 41
6566L_VRV Catalogue_A4

I N D O O R U N I T S S P E C I F I C AT I O N S I NS
DOPO
E RC UI FNII TCS AT
S P EICO
I FN S IONS
I C AT

Slim Ceiling Mounted Duct High Static Ceiling Mounted Duct

MODEL FXDQ20PDVM FXDQ25PDVM FXDQ32PDVM FXDQ40NDVM FXDQ50NDVM FXDQ63NDVM MODEL FXMQ40PBV1 FXMQ50PBV1 FXMQ63PBV1 FXMQ80PBV1 FXMQ100PBV1 FXMQ125PBV1 FXMQ140PBV1
Power supply 1-phase, 220-240V, 50/60 Hz FXDRQ32PDVM Power supply 1 phase,240-220V, 50/60Hz
Cooling capacity Cooling capacity Btu/h 15,400 19,100 24,200 30,700 38,200 47,800 54,600
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
kW 2.2 2.8 3.6 4.5 5.6 7.1 kW 4.5 5.6 7.1 9.0 11.2 14.0 16.0
Heating capacity Btu/h 17,100 21,500 27,300 34,100 42,700 54,600 61,400
Heating capacity Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
kW 5.0 6.3 8.0 10.0 12.5 16.0 18.0
kW 2.5 3.2 4.0 5.0 6.3 8.0
Casing Galvanised steel plate Galvanised steel plate
Casing Galvanised steel plate
m3/min 16/13/11 18/16.5/15 19.5/17.5/16 25/22.5/20 32/27/23 39/33/28 46/39/32
m3/min 8.0/7.2/6.4 8.0/7.2/6.4 8.0/7.2/6.4 10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0 cfm 565/459/388 635/582/530 688/618/565 883/794/706 1130/953/812 1377/1165/988 1624/1377/1130
cfm 282/254/226 282/254/226 282/254/226 371/335/300 441/388/353 582/512/459 External static pressure Pa 100(160-30)*2 100(200-50) *2 100(200-50)*2 100(200-50)*2 100(200-50) *2 100(200-50) *2 100(140-50) *2
External static pressure Pa 30-10 *2 30-10 *2 30-10 *2 44-15*2 44-15 *2 44-15 *2 Sound level (HH/H/L)*1*3 dB(A) 39/37/35 41/39/37 42/40/38 43/41/39 43/41/39 44/42/40 46/45/43
Sound level (HH/H/L)*1*3 dB(A) 33/31/29 33/31/29 33/31/29 34/32/30 35/33/31 36/34/32 Dimensions (H×W×D) mm 300x700x700 300x1000x700 300x1000x700 300x1000x700 300x1400x700 300x1400x700 300x1400x700
Dimensions (H×W×D) mm 200×700×620 200×700×620 200×700×620 200x900x620 200x900x620 200x1,100x620 Machine weight kg 27 35 35 35 45 45 46
Machine weight kg 23.0 23.0 23.0 27.0 28.0 31.0 Piping connections Liquid (Flare) mm Ø 6.4 Ø 6.4 Ø 9.5 Ø 9.5 Ø 9.5 Ø 9.5 9.5
Gas (Flare) mm Ø 12.7 Ø 12.7 Ø 15.9 Ø 15.9 Ø 15.9 Ø 15.9 15.9
Piping connections Liquid (Flare) mm Ø 6.4 Ø 6.4 Ø 6.4 Ø 6.4 Ø 6.4 Ø 9.5
Drain mm VP25( External dia.32 Internal dia.25)
Gas (Flare) mm Ø 12.7 Ø 12.7 Ø 12.7 Ø 12.7 Ø 12.7 Ø 15.9
*Optional PM2.5 filter is available upon request
Drain mm VP20 (External Dia. 26/Internal Dia. 20)

Low Static Ceiling Medium Static Ceiling


Mounted Duct Mounted Duct

MODEL FXMQ40ARV1 FXMQ50ARV1 FXMQ63ARV1 FXMQ80ARV1 FXMQ100ARV1 Model FXSQ-A2VEB 15


FXSQ-A2VEB 20 15A 2520A 3225A 40 50 63 80 100 125 140
Power Supply 1 phase, 220-240V,50Hz / 220V,60Hz
Power supply 1-phase, 220V / 240V, 50/60 Hz
Cooling capacity Btu/h 15,400 19,100 24.200 30,700 38,200 Cooling Capacity Btu/h 5,800 7,500 9,500 12,300 15,400 19,100 24,200 30,700 38,200 47,800 54,600
kW 4.5 5.6 7.1 9.0 11.2 kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 16.0

Heating capacity Btu/h 15,400 19,100 24.200 30,700 38,200 Heating Capacity Btu/h 6,500 8,500 10,900 13,600 17,000 21,500 27,300 34,000 42,600 54,600 61,400

kW 4.5 5.6 7.1 9.0 11.2 kW 1.9 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 18.0
Casing Galvanised Steel Plate
Casing Galvanised steel plate
Airflow Rate - Cooling (H/M/L) m3/min 8.7/7.5/6.5 9.0/7.5/6.5 9.0/7.5/6.5 9.5/8.0/7.0 15/12.5/11 15.2/12.5/11 21/18/15 23/19.5/16 32/27/23 36/31.5/26 39/34/28
Airflow rate (H/L) m3/min 15/12 19/16 24/20 30/25 34/29
CFM 307/265/229 318/265/229 318/265/229 335/282/247 530/441/388 537/441/388 741/635/530 812/688/565 1130/953/812 1271/1112/918 1365/1200/988
cfm 530/424 671/565 847/706 1059/883 1200/1024
External Static Pressure (H/Nom) Pa 150/30 150/40 150/50
External static pressure Pa 30-50 *3 30-50 *3 30-50 *3 30-50 *3 30-60 *3
Sound Level (H/M/L) dB(A) 29.5/28/25 30/28/25 31/29/26 35/32/29 33/30/27 35/32/29 36/34/31 39/36/33 41.5/38/34
Sound level (H/L) at 50 Hz dB(A) 39/37 41/39 42/40 43/41 44/42
Dimensions (HxWxD) mm 245x550x800 245x700x800 245x1000x800 245x1400x800 245x1550x800
Sound level (H/L) at 60 Hz dB(A) 43/37 49/42 40/34 46/43 51/40
Machine Weight kg 23.5 24 28.5 29 35.5 36.5 46 47 51
Dimensions (H×W×D) mm 300x700x700 300x700x700 300x1000x700 300x1000x700 300x1000x700
Piping Connections Liquid (Flare) mm OD 6.35 OD 9.52
Machine weight kg 27 28 35 35 36
Gas (Flare) mm OD 12.7 OD 15.9
Piping Liquid (Flare) mm 6.4 6.4 9.5 9.5 9.5 mm
mm Drain VP20 (External Dia. 26/ Internal Dia. 20)
connections Gas (Flare) 12.7 12.7 15.9 15.9 15.9
Drain mm VP25 (External Dia. 32/Internal Dia. 25) Notes:
Specifications are based on the following conditions:
Notes: Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Specifications are based on the following conditions: The capacity of indoor unit is only for reference. The actual capacity of indoor unit is based on the total capacity index.
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level dierence: 0 m. Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
• The capacity of indoor unit is only for reference. The actual capacity of indoor unit is based on the total capacity index. During actual operation, these values usually are somewhat higher as a result of ambient conditions.
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. * 1: Power consumption values are based on conditions of rated external static pressure.
During actual operation, these values usually are somewhat higher as a result of ambient conditions. *2: External static pressure can be modified using a remote controller that offers thirteen (FXMQ40PBV1), fourteen

* 1: Values are based on the following conditions: FXDQ-PDVM: external static pressure of 10 Pa; FXDQ-NDVM: external static pressure of 15 Pa. (FXMQ50-125PBV1) or ten (FXMQ140PBV1) levels of control. These values indicate the lowest and highest possible static pressures.

* 2: External static pressure is changeable to set by the remote controller. This pressure means“High static pressure - Standard”. The standard static pressure is 100 Pa

(Factory setting is 10 Pa for FXDQ-PDVM models and 15 Pa for FXDQ-NDVM models.)

* 3: For FXMQ-ARV1 series, 30 Pa is rated static pressure and 50 (60) Pa is maximum static pressure

* 4: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation

can be obtained by adding 5 dB(A).